Loading...
HomeMy WebLinkAboutTHE ODELL WINE PROJECT - MJA190002 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANSE. LINCOLN AVE. LOGAN AVE. MULBERRY STREET LAMAY AVE. 1ST STREET 2ND STREET 3RD STREET BUCKINGHAM STREET RIVERSIDE AVE. Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 C000 COVER SHEET 1 OCTOBER 2019 PROJECT LOCATION VICINITY MAP NORTH OWNER/APPLICANT CONTACT INFORMATION PROJECT TEAM: SITE ENGINEER Andy Reese Northern Engineering Services, Inc. 301 N. Howes St., Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 ARCHITECT SURVEYOR PLANNER/LANDSCAPE ARCHITECT OWNER/APPLICANT CONTACT INFORMATION PROJECT TEAM: Michael McBride McBrideLA 2339 Spruce Creek Drive Fort Collins, Colorado 80528 (970) 402-0438 Brenden McGivney Odell Investments, LLC Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 C001 GENERAL & CONSTRUCTION NOTES 2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R A. GENERAL NOTES 1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 8. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 9. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. VAULT ELEC CONTROL IRR W W W W W W W W W W W W W W W W CTV CTV CTV CTV CTV CTV CTV CTV CTV SS W SS SS SS SS SS D 6" SS 8" PW C S W G G G G G G G G G G CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E E E E E E E E E E T X AC M MH VAULT CABLE GGG AC AC M X X X X X X X X X X X X X X X X X X X X X X X E. LINCOLN AVE. EXISTING POND EXISTING CONCRETE APRON EXISTING BUILDING (824 E. LINCOLN AVE.) ODELL BREWING COMPANY (800 E. LINCOLN AVE.) EXISTING OUTDOOR PATIO EXISTING PARKING LOT EXISTING OVERHEAD STRUCTURE EXISTING SIDEWALK HORSETOOTH HOT SAUCE (832 E. LINCOLN AVE.) EXISTING SIDEWALK EXISTING RETAINING WALL EXISTING VALLEY PAN EXISTING DRIVEWAY PROPOSED CONCRETE DRIVEWAY PROPOSED CONCRETE DRIVEWAY PROPOSED CONCRETE DRIVEWAY PROPOSED VAULT ELEC CONTROL IRR SS SS SS SS D 8" PW G G G G G G G G G CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E E E E E E E E E E E E W W W W W W W W W T T T T T T T T X A C T T SS SS SS SS CONTROL IRR D T X AC D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST D D H Y D W C S CONTROL IRR CONTROL IRR CONTROL IRR CONTROL CONTROL IRR IRR MH VAULT CABLE D D D C.O. V.P. C.O. C.O. AC AC M X X X X X X X X X X ST ST ST ST ST X X X CONTROL IRR D T X AC D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST D D H Y D W C S CONTROL IRR CONTROL IRR CONTROL IRR CONTROL CONTROL IRR IRR MH VAULT CABLE D D D C.O. V.P. C.O. C.O. AC AC M X X X X X X X X X X ST ST ST ST ST X X X 1' 0.5' FINISHED GROUND PAVERS 1.5' FINISHED GROUND 1' 0.5' 0.5' PAVERS 1.5' 9" 1' FINISHED GROUND LANDSCAPING AREA 1.5' FINISHED GROUND 0.5' 0.5' EXISTING UTILITY PAD 6' PAVERS 0.5' 0.5' 1.5' Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 VAN- ACCESSIBLE PARKING MIN. MIN. ONE IN EVERY EIGHT ACCESSIBLE SPACES, BUT NOT LESS THAN ONE, SHALL BE VAN ACCESSIBLE. ONE SIGN PER SPACE Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 C501 UTILITY DETAILS 9 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 200 WATER BEDDING REQUIREMENTS 201 TYPICAL WATER SERVICE 203 TYPICAL NYLOPLAST DRAIN BASIN INSTALLATION DWG SIZE A SCALE 1:40 SHEET 1 OF 1 DWG NO. 7001-110-042 REV C 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com 8 IN - 30 IN TYPICAL INSTALLATION OPTIONS TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 8-10-00 THIS PRINT DISCLOSES SUBJECT MATTER IN WHICH DRAWN BY AWA NYLOPLAST HAS PROPRIETARY RIGHTS. THE RECEIPT OR POSSESSION OF THIS PRINT DOES NOT CONFER, TRANSFER, OR LICENSE THE USE OF THE DESIGN OR TECHNICAL INFORMATION SHOWN HEREIN REPRODUCTION OF THIS PRINT OR ANY INFORMATION CONTAINED HEREIN, OR MANUFACTURE OF ANY ARTICLE HEREFROM, FOR THE DISCLOSURE TO OTHERS IS FORBIDDEN, EXCEPT BY SPECIFIC WRITTEN PERMISSION FROM NYLOPLAST. 8-10-00 CJA DUCTILE IRON DO NOT POLLUTE DRAINS TO WATERWAYS T X ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST M X X X X X X X X X X ST ST ST ST ST X X X X X X X X X X X X X U D UD UD UD UD UD UD UD SF SF SF SF SF SF SF SF SF E. LINCOLN AVE. EXISTING POND EXISTING CONCRETE APRON EXISTING BUILDING (824 E. LINCOLN AVE.) ODELL BREWING COMPANY (800 E. LINCOLN AVE.) EXISTING OUTDOOR PATIO EXISTING PARKING LOT Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 C601 EROSION CONTROL DETAILS 11 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 001 CONCRETE WASHOUT AREA 004 SILT FENCE CURB INLET PROTECTION POSTS PREASSEMBLED SILT FENCE POSTS SHALL OVERLAP AT JOINTS SO THAT NO GAPS EXIST IN SILT FENCE. NOTE: THICKNESS OF GEOTEXTILE POST SHALL BE JOINED AS SHOWN, THEN HAS BEEN EXAGGERATED. ROTATED 180° IN DIRECTION SHOWN AND DRIVEN INTO THE GROUND. SILT FENCE JOINTS DRIVE POSTS VERTICALLY INTO THE GROUND TO A MINIMUM DEPTH OF 18". EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 4" DEEP ALONG THE LINE OF POSTS AND UPSLOPE FROM THE BARRIER. ANCHOR TRENCH SHALL BE EXCAVATED BY HAND, WITH TRENCHER, OR WITH SILT FENCE INSTALLATION MACHINE. NO ROAD GRADERS, BACKHOES, ETC. SHALL BE USED. NOT LESS THAN THE BOTTOM 1' OF THE SILT FENCE FABRIC SHALL BE BURIED IN THE TRENCH. THE TRENCH SHALL BE COMPACTED BY HAND, WITH "JUMPING JACK" OR BY WHEEL ROLLING. COMPACTION SHALL BE SUCH THAT THE SILT FENCE RESISTS BEING PULLED OUT OF ANCHOR TRENCH BY HAND. SILT FENCE INDICATED IN THE PLANS SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES. USE WOOD POSTS OR OTHER MATERIAL AS ACCEPTED BY THE CITY. INSTALLATION NOTES: 1. D ST ST C S W W C S C.O. CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV C.O. C.O. T X AC X X X X X D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST D MH VAULT CABLE D D D C.O. V.P. C.O. C.O. AC AC M X X X X X X X X X X ST ST ST ST UD UD UD UD UD UD UD UD 0.44 ac. A-1 0.03 ac. B 0.17 ac. OS-1 a-1 b os-1 0.03 ac. OS-2 0.19 ac. C 0.39 ac. A-2 os-2 a2 c EXISTING INLET EAST POND (EXISTING) EXISTING OUTLET STRUCTURE EXISTING STORM MH RIM=4946.15 INV IN=4942.40 (N) INV OUT=4942.33 (SW) EXISTING STORM MH RIM=4946.20 INV IN=4942.08 (N) INV IN=4942.12 (NE) INV OUT=4942.01 (S) EXISTING RETAINING WALL CONCRETE WALK CONCRETE WALK OUTDOOR PATIO EXISTING CONCRETE APRON EXISTING BUILDING (824 E. LINCOLN AVE.) ODELL BREWING COMPANY (800 E. LINCOLN AVE.) EXISTING OUTDOOR PATIO EXISTING PARKING LOT EX. OVERHEAD STRUCTURE EXISTING STORM MH PERMEABLE PAVERS PERMEABLE PAVERS EXISTING SIDEWALK EXISTING DOWNSPOUT (TYP.) EXISTING BOLLARD (TYP.) EXISTING VALLEY PAN PROPOSED RETAINING WALL PROPOSED BRIDGE PROPOSED INLET PROPOSED CLEANOUT (TYP.) PROPOSED BOULDER WALL PROPOSED (RE: LANDSCAPE ARCHITECT) VALLEY PAN RAISED PLANTER (RE: LANDSCAPE ARCHITECT) PROPOSED SWALE EXISTING STORM MH RIM=4947.83 (RECORD) INV IN=4943.22 (N) INV OUT=4943.23 (S) EXISTING 327.12 LF OF 15" HDPE STORM SEWER S = 0.25% PROPOSED INLET Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R C602 DRAINAGE EXHIBIT 12 LEGEND: PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPERTY BOUNDARY DESIGN POINT A FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 1 1 B2 1.45 ac PROPOSED AREA DRAIN INLET PROPOSED UNDERDRAIN UD 2. 3. 4. 5. 6. 7. THE CONTRACTOR SHALL INSPECT SILT FENCE EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT UPSTREAM SEDIMENT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM SEDIMENT REACHES A DEPTH OF 6". SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. IF ANY DISTURBED AREA EXISTS AFTER REMOVAL, IT SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. MAINTENANCE NOTES: 1. 2. 3. 4" MIN. 4" MIN. 1 1 2" x 1 1 2" WOODEN FENCE POSTS SF 005 SWALE WATTLE DIKE SF WD IP CWA EXISTING SIDEWALK EXISTING SIDEWALK 6' SIDEWALK EXISTING DRIVEWAY SF SF SF SF IP IP IP IP IP IP WD CWA EXISTING OVERHEAD STRUCTURE EXISTING RETAINING WALL EDGE OF EASEMENT PER REC. NO 19900004624 (UTILITY EASEMENT) EDGE OF EASEMENT PER REC. NO 19950074251 SF SF WD WD SF SF SF WD SF SF WD IP Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH C600 EROSION CONTROL PLAN 10 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R BENCHMARK/BASIS OF BEARING: SILT FENCE SF SF 1. CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2. SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone________________________________ 3. REFER TO THE FINAL DRAINAGE REPORT FOR ODELL WINE PROJECT DATED AUGUST, 28TH 2019 BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. 4. REMOVE SEDIMENT THAT IS TRACKED ONTO THE PUBLIC RIGHT OF WAY DAILY OR MORE FREQUENTLY ASS NEEDED. EXCESS SEDIMENT IN THE ROADWAY INDICATES THAT THE STABILIZED CONSTRUCTION ENTRANCE NEEDS MAINTENANCE. 5. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 6. REMOVE ALL ACCUMULATED SEDIMENT AND DEBRIS FROM THE DANDY SACK, SURFACE AND VICINITY OF THE UNIT AFTER EACH STORM EVENT. IF USING OPTIONAL OIL ABSORBENTS, REMOVE AND REPLACE ABSORBENTS WHEN THEY NEAR SATURATION. GENERAL NOTES: WATTLE DIKE WD CONCRETE WASH AREA CWA INLET PROTECTION IP LEGEND: EXISTING STORM SEWER ST EASEMENT LINE PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING TREES PROPOSED CURB D EXISTING INLET GRATE EXISTING STORM MANHOLE EXISTING SIGN EXISTING POWER POLE EXISTING ROOF DRAIN EXISTING DRY WELL BENCHMARK #1: City of Fort Collins Benchmark 3-00 Location: On a parapet wall at the Northwest end of the Lincoln Ave. bridge near the Northeast corner of Lincoln Ave. and Willow st. Elevation= 4967.33 (NAVD88) BENCHMARK #2: City of Fort Collins Benchmark R 402 Location: At the junction of 9th street and Lincoln Ave. in the East edge of the concrete footing for highline tower number 29, 156.8ft North of the centerline of the Avenue, 73.2 ft West of the Centerline of the street, and .7 ft West of the East edge of the footing. Elevation= 4942.21 (NAVD88) Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18' Basis of Bearings North line of the Subdivision Plat of Odell Brewing Company First Replat as bearing South 89°11'23" West NYLOPLAST T S A L P O L Y N D U C T I L E I R O N S T L A P O L Y N D U C T I L E I R O N DUCTILE IRON DO NOT POLLUTE DRAINS TO WATERWAYS NYLOPLAST WHEN ARE DRAIN BASINS USED? 2808AG _ _ X 2810AG _ _ X 2812AG _ _ X 2815AG _ _ X 2818AG _ _ X 2824AG _ _ X 2830AG _ _ X TYPICAL INSTALLATIONS TYPICAL INSTALLATION OF NYLOPLAST DRAIN BASIN AND INLINE DRAIN 1: TO ENTER AN EXISTING LINE USING A TEE & RISER 2: AT THE BEGINNING OF A DRAIN LINE USING AN ELBOW & RISER TEE ELBOW 12" DRAIN BASIN 2 INLET & OUTLET ADAPTERS CAN BE PUT ON ANY ANGLE 1: TO CHANGE ELEVATION 2: TO CHANGE PIPE DIAMETER 3: TO CHANGE PIPE TYPE 4: FOR SHALLOW APPLICATIONS 5: TO CHANGE DIRECTION A° RISER DRAIN BASIN INLINE DRAIN 10" INLINE DRAIN 10" INLINE DRAIN 3 VARIABLE ELEVATION WATERTIGHT ADAPTERS AVAILABLE FOR MOST COMMON PLASTIC PIPING SYSTEMS 8" 6" CORRUGATED HDPE PIPE SMOOTH WALL PVC 1 - STRUCTURES & ADAPTERS AVAILABLE IN SIZES 8" - 30" 2 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°, TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012, 7001-110-013, & 7001-110-014 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS SEE DRAWING NO. 7001-110-065 NYLOPLAST CLEANOUT END CAP ADJUST GRADE PER ENGINEERS PLAN INJECTION MOLDED WT TEE INSERT INJECTION MOLDED, GASKETED SPIGOT BY BELL REDUCER INJECTION MOLDED WT TEE HDPE PIPE (TYP) GASKETED CONNECTION INJECTION MOLDED WT 90° BEND DOWNSPOUT ADAPTER INSERTED IN RISER PIPE BUILDING FACE FINISHED GRADE DWG SIZE A SCALE 1:40 SHEET 1 OF 1 DWG NO. 7001-110-144 REV D 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com DRAIN BASIN WITH STANDARD GRATE QUICK SPEC INSTALLATION DETAIL TITLE PROJECT NO./NAME MATERIAL DATE APPD BY DATE 1-23-06 DRAWN BY EBC 1-23-06 CJA 5 ADAPTER ANGLES VARIABLE 0° - 360° ACCORDING TO PLANS A 18" MIN WIDTH GUIDELINE 8" MIN THICKNESS GUIDELINE 3 VARIABLE SUMP DEPTH ACCORDING TO PLANS (6" MIN ON 8" - 24", 10" MIN ON 30") 4" MIN ON 8" - 24" 6" MIN ON 30" MINIMUM PIPE BURIAL DEPTH PER PIPE MANUFACTURER RECOMMENDATION 3 VARIABLE INVERT HEIGHTS AVAILABLE (ACCORDING TO PLANS/TAKE OFF) THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. 4 VARIOUS TYPES OF INLET & OUTLET ADAPTERS AVAILABLE: 4" - 30" FOR CORRUGATED HDPE (ADS N-12, ADS SINGLE WALL, HANCOR DUAL WALL), SDR 35, SCH 40 DWV, CORRUGATED & RIBBED PVC WATERTIGHT JOINT (CORRUGATED HDPE SHOWN) NYLOPLAST DRAIN BASIN 1 - 8" - 30" GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05, WITH THE EXCEPTION OF THE 8" - 15" BRONZE GRATES 2 - 12" - 30" FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS. RISERS ARE NEEDED FOR BASINS OVER 84" DUE TO SHIPPING RESTRICTIONS. SEE DRAWING NO. 7001-110-065 4 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE (ADS & HANCOR DUAL WALL) & SDR 35 PVC 5 - ADAPTERS CAN BE MOUNTED ON ANY ANGLE 0° TO 360°. TO DETERMINE MINIMUM ANGLE BETWEEN ADAPTERS SEE DRAWING NO. 7001-110-012, 7001-110-013, & 7001-110-014. 6 - GRATES SHALL MEET H-10 LOAD RATING FOR 12" - 24" PED 7 - GRATES SHALL MEET H-20 LOAD RATING FOR 30" PED & 12" - 30" STD & SOLID 8 - ALL BRONZE GRATES, DROP IN GRATES, & 8" & 10" PED/STD GRATES & SOLID COVERS ARE RATED FOR LIGHT DUTY APPLICATIONS ONLY 9 - DOME GRATES HAVE NO LOAD RATING TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. 1 2 INTEGRATED DUCTILE IRON FRAME & GRATE TO MATCH BASIN O.D. 204 STANDARD NYLOPLAST DRAIN BASIN 202 STORMWATER BEDDING REQUIRED REQUIRED PER SPACE ONE SIGN REQUIRED PER SPACE ONE SIGN CAR ACCESSIBLE VAN ACCESSIBLE "UNIVERSAL DESIGN" CAR & VAN ACCESSIBLE OR A "UNIVERSAL" PARKING SPACE DESIGN MAY BE USED. THIS DESIGN IS USED TO ACCOMMODATE CAR & VAN ACCESSIBLE PARKING SPACES, WHICH ELIMINATES THE NEED FOR TWO SIGN TYPES. 8' 5' 8' 8' 8' 8' 11' 5' 11' 11' 5' RESERVED RESERVED PARKING RESERVED PARKING R7-8 R7-8 R7-8 102 6" VERTICAL CURB 101 HANDICAP PARKING REQUIREMENTS 103 9" FLUSH CURB 104 1.0' WIDE VERTICAL CURB C500 SITE DETAILS 8 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R 106 1.0' WIDE FLUSH CURB NOTES: 1. CONTRACTOR MUST FOLLOW THE INTERLOCKING CONCRETE PAVEMENT INSTITUTE (ICPI) ASSOCIATION AND BRICK INDUSTRY ASSOCIATION CONSTRUCTION SPECIFICATIONS FOR COMPLETE INSTALLATION INFORMATION. 2. IT IS RECOMMENDED THAT A CERTIFIED PERMEABLE PAVEMENT INSTALLER PERFORM THE INSTALLATION OF THE PAVERS. 3. SUBGRADE PREPARATION: 3.1. CONTRACTOR TO VERIFY THAT SUBGRADE PREPARATION, COMPACTION DENSITY AND ELEVATIONS CONFORM TO THE APPROVED DRAWINGS AND CONSTRUCTION SPECIFICATIONS. 3.2. MINIMUM ALLOWABLE SUBGRADE SLOPE IS 0.5%. 4. EDGE RESTRAINTS: 4.1. CONCRETE EDGE RESTRAINTS (CURB AND GUTTER OR APRON) SHALL BE INSTALLED AROUND THE PERIMETER OF THE PAVER AREA TO PROVIDE FOR PROPER EDGE RESTRAINT AND ALLOW FOR ADEQUATE SEPARATIONS BETWEEN PAVERS AND OTHER SURFACE TYPES. 4.2. A LINEAR-EDGE CONCRETE COLLAR TO BE POURED AROUND ALL PENETRATIONS (INCLUDING CLEANOUTS) THROUGH THE PAVER SECTION . 4.3. 5. GEOTEXTILE LINERS: 5.5. GEOTEXTILE LINERS (PERMEABLE OR IMPERMEABLE AS PER PLAN) SHALL BE INSTALLED ALONG PERIMETER OF CROSS-SECTION OF THE PAVER AREA. 5.3. GEOTEXTILE LINERS SHALL BE PLACED IN ACCORDANCE WITH MANUFACTURER'S STANDARDS AND RECOMMENDATIONS. ALL SEAMS AND OPENINGS IN THE LINER SHALL BE SEALED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND SPECIFICATIONS. 5.4. WHERE USED, IMPERMEABLE GEOMEMBRANE SHEET / LINER SHALL BE 40 MIL THICK, HIGH-DENSITY POLYETHYLENE DESIGNED SPECIFICALLY FOR FLEXIBLE GEOMEMBRANE APPLICATIONS. ADJACENT STRIPS OF IMPERMEABLE LINER SHALL OVERLAP A MINIMUM OF 18", OR PER MANUFACTURER'S SPECIFICATION. 6. AGGREGATES: 6.1. ALL AGGREGATES SHALL BE ANGULAR, CRUSHED, WASHED GRANITE ROCK AND SHALL BE WASHED ROCK, CLEAN OF DEBRIS AND WITH NO MORE THAN 1% FINES. 6.2. SUB-BASECOURSE AGGREGATE SHALL BE GRADATION ASTM #2, #3, OR #4. ASTM #4 WILL NOT BE ALLOWED FOR USE WITH SUBSURFACE STORMWATER DETENTION SYSTEMS. 6.3. BASECOURSE AGGREGATE SHALL BE GRADATION ASTM #57 OR #67. 6.4. LEVELING COURSE SHALL BE GRADATION ASTM #8, #89 OR #9. 6.5. LEVELING COURSE SHALL BE INSTALLED ALL THE WAY TO THE FINISHED GRADE SURFACE OF THE PAVERS. 6.6. THE AGGREGATE SHALL BE PLACED IN 6-INCH (MAX.) LIFTS, COMPACTING EACH LIFT WITH A 10-TON, OR HEAVIER, VIBRATING STEEL DRUM ROLLER. MAKE AT LEAST FOUR PASSES WITH THE ROLLER, WITH THE INITIAL PASSES MADE WHILE VIBRATING THE ROLLER AND THE FINAL ONE TO TWO PASSES WITHOUT VIBRATION. 6.7. CONTRACTOR MAY BE REQUIRED TO PROVIDE COMPACTION TESTING. 7. UNDERDRAIN: 7.1. UNDERDRAIN PIPE TO BE PERFORATED OR SLOTTED. PERFORATIONS OR SLOTS TO BE NO WIDER THAN 3/8" TO ENSURE AGGREGATE DOES NOT FALL INTO OR CLOG THE OPENINGS. 7.2. DO NOT WRAP UNDERDRAIN WITH GEOTEXTILE OR SOCK. 8. CLEANOUTS: 8.1. PROVIDE CLEANOUTS (AS PER PLAN) TO ALLOW INSPECTION (BY CAMERA) OF THE UNDERDRAIN SYSTEM DURING AND AFTER CONSTRUCTION. 8.2. CLEANOUTS SHALL BE PROVIDED AT EACH BEND GREATER THAN OR EQUAL TO 90° AND EVERY 100' ALONG A STRAIGHT RUN. CLEANOUT SHALL BE INSTALLED PER THE APPROVED PLANS. 8.3. CLEANOUTS SHALL BE A SOLID WALL PVC STRUCTURE FOR ALL VERTICAL SECTIONS WITH FITTINGS TO CONNECT TO DISTRIBUTION AND UNDERDRAIN PIPING MATERIALS, AS REQUIRED. 8.4. PROVIDE OBSERVATION PORT AT DOWNSTREAM END OF EACH PERMEABLE PAVEMENT SECTION, CONNECTED TO UNDERDRAIN WHEN PRESENT. 8.5. THE CLEANOUT FRAME AND COVER SHALL BE DUCTILE IRON AND STAMPED "CLEANOUT." 9. PAVERS: 9.1. CONTRACTORS MUST INSTALL A PAVER PRODUCT THAT IS APPROVED BY THE ICPI. 9.2. FINISHED GRADE OF THE PAVER SURFACE TO BE EVENLY SLOPED AND FLUSH WITH THE ADJACENT EDGE RESTRAINTS. 9.3. ALL PENETRATIONS THROUGH THE PAVER SURFACE, INCLUDING CLEANOUT LIDS, SHALL BE INSTALLED WITH A CONCRETE COLLAR POURED AROUND THE PERIMETER. 10. POST-INSTALLATION: 10.1. LOOSE MATERIALS SHALL NOT BE STORED ON THE PERMEABLE PAVEMENT AREA. 10.2. THE CONTRACTOR SHALL, AT ALL TIMES DURING AND AFTER SYSTEM INSTALLATION, PREVENT SEDIMENT, DEBRIS AND DIRT FROM ANY SOURCE FROM ENTERING THE PERMEABLE PAVEMENT SYSTEM. UNDISTURBED SOIL SUBGRADE 4" MIN DIAMETER PERFORATED PVC UNDERDRAIN 3.4' MIN 4" TOPSOIL MAX 1 8" WIDTH HAND-TIGHT JOINTS FILLED WITH LEVELING COURSE MATERIAL TO SURFACE 2-3" DEPTH OF LEVELING COURSE PERMEABLE INTERLOCKING CONCRETE PAVERS EDGE RESTRAINT (CONCRETE APRON OPTION) EDGE RESTRAINT (CURB AND GUTTER OPTION) 2" MIN 6" 6" MIN CLEANOUTS WITH CONCRETE COLLAR (AS PER PLAN) PERFORATED UNDERDRAIN @ 0.50% MIN SLOPE GEOTEXTILE LINER (AS PER PLAN) 12" MIN CROSS-SECTION DETAIL 20" MIN 6" PREPARED SUBGRADE @ 0.50% MIN SLOPE 3.4' MIN DEPTH OF SUB-BASECOURSE 4" DEPTH OF BASECOURSE PAVER SURFACE @ 0.50% MIN OR 3.00% MAX SLOPE APPROVED: DETAILS DRAWN BY: CONSTRUCTION DATE REVISED: STORMWATER DETAIL PERMEABLE INTERLOCKING CONCRETE PAVERS DECEMBER 2018 HEM D-54 100 PERMEABLE INTERLOCKING CONCRETE PAVERS 105 SIDEWALK DETAIL TM PAVER DISCHARGE BASIN TM TYPICAL PAVER SECTION @ UNDERDRAIN PERMEABLE PAVER OUTFALL SUB-BASE COURSE BASE COURSE BEDDING COURSE FILTRAPAVE PAVER 6" SLOTTED UNDERDRAIN SUB-BASE COURSE BASE COURSE BEDDING COURSE FILTRAPAVE PAVER SUBGRADE GRANULAR BEDDING CONCRETE CURB ROOFDRAIN LEADER DISCHARGE BASIN (SOLID LID) CDOT CLASS B GEOTEXTILE SEPARATOR FABRIC FINISHED GRADE ELEVATION SUBGRADE ELEVATION TM NOTE: 1. CONTRACTOR TO PROVIDE GEOFABRIC CLOAKING AROUND OUTLET PIPE. SUB-BASE COURSE BASE COURSE BEDDING COURSE FILTRAPAVE PAVER 24" CONCRETE EDGE RESTRAINT PVC OUTFALL PIPE CDOT CLASS B GEOTEXTILE SEPARATOR FABRIC CLEANOUT BASIN 109 DIMENSIONS FOR SLOTTED PVC PIPE SCREEN SLOT TABLE A B C D E F PIPE SIZE ROWS OF SLOTS MAXIMUM SLOT LENGTH MAXIMUM SLOT WIDTH APPROX. SLOT/ROW PER FOOT APPROX. SLOT SPACING MINIMUM OPEN AREA PER FOOT 8" 3 (MIN.) - 6 (MAX.) 2.35" 0.032" 14 3/4" 3.15 SQ. IN. 112 108 107 PRIVATE UNDERDRAIN BASIN 4" MIN EXTEND MIN. 6" INTO SUBGRADE 6" VARIES (REFER TO STORM DRAIN PLAN) INTEGRATED DUCTILE IRON FRAME & GRATE TO MATCH BASIN O.D. NOTES: 1 - GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS SEE DRAWING NO. 7001-110-065 4 - PERFORATIONS SHOULD NOT BE ON OR WITHIN 1" OF ADAPTERS. 5 - HOLES SHOULD BE STAGGERED EVERY OTHER ROW, AS SHOWN. 6 - MIN. 90° SEPARATION BETWEEN HOLES (MAX. 4 HOLES PER ROW. 2" MIN Ø .375" MAX SIDE VIEW HOLE SIZE & LOCATION NTS ENLARGED TO SHOW DETAIL 6" THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. TOP 10" TO BE SOLID, WITHOUT PERFORATIONS 10" SOLID TOP NO PERFORATIONS WITHIN 1" OF ADAPTORS OPEN BOTTOM (NO BOTTOM CAP) 111 8" MIN. THICKNESS GUIDELINE 12" MIN WIDTH GUIDELINE NOTE: CONTRACTOR SHALL USE SQUARE COLLAR IN PERMEABLE PAVER AREAS. COLLAR SHALL BE ORIENTED WITH PAVERS SO AS TO REDUCE IRREGULAR CUTS OR PAVER SHAPES. 4.25" ORIFICE OPENING 30" FRAME AND GRATE REMOVABLE OR FIXED OUTLET ORIFICE CAP 15" OUTLET 12" INLET 30" DRAIN BASIN BODY HDPE SUMP INSERT ADDED INTO BOTTOM OF STRUCTURE, UP TO INVERT ELEVATION. 110 DRAIN BASIN w/ OUTLET ORIFICE CAP EXTEND MIN. 6" INTO SUBGRADE 8" VARIES (REFER TO STORM DRAIN PLAN) NOTES: 1 - GRATES/SOLID COVERS SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 2 - FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05 3 - DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS SEE DRAWING NO. 7001-110-065 4 - PERFORATIONS SHOULD NOT BE ON OR WITHIN 1" OF ADAPTERS. 5 - HOLES SHOULD BE STAGGERED EVERY OTHER ROW, AS SHOWN. 6 - MIN. 90° SEPARATION BETWEEN HOLES (MAX. 4 HOLES PER ROW) 2" MIN Ø .375" MAX SIDE VIEW HOLE SIZE & LOCATION NTS ENLARGED TO SHOW DETAIL 6" THE BACKFILL MATERIAL SHALL BE CRUSHED STONE OR OTHER GRANULAR MATERIAL MEETING THE REQUIREMENTS OF CLASS II MATERIAL AS DEFINED IN ASTM D2321. BEDDING & BACKFILL FOR SURFACE DRAINAGE INLETS SHALL BE PLACED & COMPACTED UNIFORMLY IN ACCORDANCE WITH ASTM D2321. TOP 12" TO BE SOLID, WITHOUT PERFORATIONS 12" SOLID TOP NO PERFORATIONS WITHIN 1" OF ADAPTORS OPEN BOTTOM (NO BOTTOM CAP) TRAFFIC LOADS: CONCRETE SLAB DIMENSIONS ARE FOR GUIDELINE PURPOSES ONLY. ACTUAL CONCRETE SLAB MUST BE DESIGNED TAKING INTO CONSIDERATION LOCAL SOIL CONDITIONS, TRAFFIC LOADING, & OTHER APPLICABLE DESIGN FACTORS. 8" MIN. THICKNESS GUIDELINE 12" MIN WIDTH GUIDELINE NOTE: CONTRACTOR SHALL USE SQUARE COLLAR IN PERMEABLE PAVER AREAS. COLLAR SHALL BE ORIENTED WITH PAVERS SO AS TO REDUCE IRREGULAR CUTS OR PAVER SHAPES. 113 PRIVATE UNDERDRAIN CLEANOUT BASIN X X X X X X X X X X UD UD UD UD UD UD UD UD E. LINCOLN AVE. EXISTING INLET EXISTING POND EXISTING OUTLET STRUCTURE EXISTING STORM MH RIM=4946.15 INV IN=4942.40 (N) INV OUT=4942.33 (SW) EXISTING STORM MH RIM=4946.20 INV IN=4942.08 (N) INV IN=4942.12 (NE) INV OUT=4942.01 (S) PROPOSED 6" VERTICAL CURB PROPOSED BRIDGE (RE: ARCHITECT) PROPOSED 1.0' WIDE FLUSH CURB CONCRETE WALK CONCRETE WALK EXISTING CONCRETE APRON EXISTING BUILDING (824 E. LINCOLN AVE.) ODELL BREWING COMPANY (800 E. LINCOLN AVE.) EXISTING OUTDOOR PATIO EXISTING PARKING LOT EX. OVERHEAD STRUCTURE 1.3% 1.1% 1.7% 1.1% 0.9% 2.0% 2.0% 1.3% 2.9% 3.1% 6.2% 3.0% 2.7% EXISTING SIDEWALK EXISTING STORM MH PROPOSED 1.0' WIDE VERTICAL CURB. EXPOSE TOP 6" OF BACK OF VERTICAL CURB. PERMEABLE PAVERS PERMEABLE PAVERS RAISED PLANTER (RE: LANDSCAPE ARCHITECT) PROPOSED 6" VERTICAL CURB 3.0% PROPOSED 1.0' WIDE FLUSH CURB PROPOSED BOULDER WALL (RE: LANDSCAPE ARCHITECT) OUTDOOR PATIO 42.50 SUB 42.19 SUB 41.22 SUB 41.50 SUB 41.98 SUB 41.99 SUB 41.31 SUB 41.37 SUB 41.59 SUB 42.55 SUB 42.34 SUB 42.11 SUB 42.28 SUB 42.55 SUB 42.39 SUB 42.61 SUB 42.52 SUB 41.10 SUB Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH C401 SUBGRADE PLAN 7 LEGEND: ST 33.43 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. SPOT ELEVATIONS DEPICTED ADJACENT TO RETAINING WALLS REPRESENT THE FINISHED GRADE ELEVATIONS AT THE LOW SIDE AND HIGH SIDE OF EACH WALL. RETAINING WALLS OVER 4 FEET IN HEIGHT, MEASURED FROM THE LOW SIDE GRADE TO THE TOP OF THE WALL, WILL REQUIRE A SEPARATE PERMIT THROUGH THE BUILDING DEPARTMENT. A SEPARATE PERMIT IS NOT REQUIRED FOR RETAINING WALLS THAT ARE NOT OVER 4 FEET IN HEIGHT, MEASURED FROM THE LOW SIDE GRADE TO THE TOP OF THE WALL, PROVIDED THE HORIZONTAL DISTANCE TO THE NEXT UPHILL RETAINING WALL IS AT LEAST EQUAL TO THE TOTAL HEIGHT OF THE LOWER RETAINING WALL. NOTES: 2.0% UD CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING STORM SEWER PROPOSED UNDERDRAIN PROPOSED STORM SEWER PROPOSED AREA DRAIN INLET PROPOSED CONTOUR EXISTING CONTOUR PROPOSED SWALE PROPOSED VERTICAL CURB & GUTTER MATCH INTO EXISTING CONCRETE PROPERTY BOUNDARY PROPOSED SPOT ELEVATION EXISTING SPOT ELEVATION PROPOSED SLOPES PEDESTRIAN ACCESS RAMPS (33.43) EXISTING DRY WELL X X X X X X X X X X UD UD UD UD UD UD UD UD E. LINCOLN AVE. EXISTING INLET REPLACE EXISTING GRATE WITH CLEANOUT. RAISE CLEANOUT TO MATCH INTO PROPOSED GRADES EXISTING POND EXISTING OUTLET STRUCTURE EXISTING STORM MH RIM=4946.15 INV IN=4942.40 (N) INV OUT=4942.33 (SW) EXISTING STORM MH RIM=4946.20 INV IN=4942.08 (N) INV IN=4942.12 (NE) INV OUT=4942.01 (S) MATCH INTO TOP OF EXISTING RETAINING WALL MATCH INTO EX. UTILITY PADS MATCH INTO EX. HANDICAP RAMP MATCH INTO EXISTING CONCRETE DRIVEWAY MATCH INTO EX. HANDICAP RAMP MATCH INTO EXISTING MATCH INTO EXISTING CONCRETE WALKS EX. FF=4946.96 PROPOSED 6" VERTICAL CURB PROPOSED BRIDGE (RE: ARCHITECT) PROPOSED 1.0' WIDE FLUSH CURB PROPOSED 9" WIDE FLUSH CURB CONCRETE WALK CONCRETE WALK EXISTING CONCRETE APRON EXISTING BUILDING (824 E. LINCOLN AVE.) ODELL BREWING COMPANY (800 E. LINCOLN AVE.) EXISTING OUTDOOR PATIO EXISTING PARKING LOT EX. OVERHEAD STRUCTURE MATCH INTO EX. SUPPORT COLUMN MATCH INTO EX. UTILITY PAD CONSTRUCT 6" VERTICAL CURB BETWEEN PAVERS AND UTILITY PAD 3.0% 6.7% 3.0% 2.9% 1.2% 1.3% 1.1% 1.7% 1.1% 0.9% 2.0% 2.0% 3.0% 1.3% 2.9% 3.1% 3.5% 5.0% 2.4% 2.5% 4.7% 6.2% 46.33 46.44 (45.84) (45.81) (45.88) 45.35 45.19 45.16 45.82 44.93 46.30 3.0% 2.7% 46.16 46.32 (46.46) 46.15 (46.34) 46.38 (46.20) (46.06) 46.11 45.94 1.7% 2.2% EXISTING SIDEWALK EXISTING STORM MH MATCH INTO EX. VALLEY PAN MATCH INTO EXISTING PROPOSED 1.0' WIDE VERTICAL CURB. EXPOSE TOP 6" OF BACK OF VERTICAL CURB. 5:1 4:1 PERMEABLE PAVERS PERMEABLE PAVERS RAISED PLANTER (RE: LANDSCAPE ARCHITECT) (46.85) (46.43) (46.67) (46.86) 46.32 46.06 46.03 46.13 2.0% 45.52 PROPOSED 6" VERTICAL CURB (46.82) (45.99) MATCH INTO EX. GRADES AROUND BASE OF TREE 45.21 3.0% 45.34 45.37 2.8% 1.4% 1.3% 1.8% 7:1 4:1 7:1 45.47 45.54 45.68 0.5% 0.5% 45.05 45.67 PROPOSED 1.0' WIDE FLUSH CURB 45.70 45.70 45.80 45.89 PROPOSED BOULDER WALL (RE: LANDSCAPE ARCHITECT) OUTDOOR PATIO Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH C400 GRADING PLAN 6 LEGEND: ST 33.43 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. SPOT ELEVATIONS DEPICTED ADJACENT TO RETAINING WALLS REPRESENT THE FINISHED GRADE ELEVATIONS AT THE LOW SIDE AND HIGH SIDE OF EACH WALL. RETAINING WALLS OVER 4 FEET IN HEIGHT, MEASURED FROM THE LOW SIDE GRADE TO THE TOP OF THE WALL, WILL REQUIRE A SEPARATE PERMIT THROUGH THE BUILDING DEPARTMENT. A SEPARATE PERMIT IS NOT REQUIRED FOR RETAINING WALLS THAT ARE NOT OVER 4 FEET IN HEIGHT, MEASURED FROM THE LOW SIDE GRADE TO THE TOP OF THE WALL, PROVIDED THE HORIZONTAL DISTANCE TO THE NEXT UPHILL RETAINING WALL IS AT LEAST EQUAL TO THE TOTAL HEIGHT OF THE LOWER RETAINING WALL. NOTES: 2.0% UD CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING STORM SEWER PROPOSED UNDERDRAIN PROPOSED STORM SEWER PROPOSED AREA DRAIN INLET PROPOSED CONTOUR EXISTING CONTOUR PROPOSED SWALE PROPOSED VERTICAL CURB & GUTTER MATCH INTO EXISTING CONCRETE PROPERTY BOUNDARY PROPOSED SPOT ELEVATION EXISTING SPOT ELEVATION PROPOSED SLOPES PEDESTRIAN ACCESS RAMPS (33.43) EXISTING DRY WELL SS SS SS D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST D D H Y D W C S W C S VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL CONTROL IRR IRR MH VAULT ELEC VAULT CABLE VAULT ELEC D D D C.O. E VAULT ELEC ELEC BRKR E GGG C.O. C.O. AC AC M T T T T X G G G G G G G G G G G E E E E E E E E E E E E E E E X X X X X X T T T T T T T T T T T X X X T T T T T T T T T T ST ST ST ST ST SS SS SS SS SS SS SS E E E E E X X X X X X X X X X X X X UD UD UD W W W W W W W W UD UD UD UD UD 3 4" WATER METER. UPSIZE SERVICE LINE TO 1 1 4" AT 5' AFTER THE METER PIT. CONNECT 1 1 4" WATER SERVICE TO BUILDING E. LINCOLN AVE. EXISTING INLET EXISTING POND EXISTING OUTLET STRUCTURE EXISTING STORM MH RIM=4946.15 INV IN=4942.40 (N) INV OUT=4942.33 (SW) EXISTING STORM MH RIM=4946.20 INV IN=4942.08 (N) INV IN=4942.12 (NE) INV OUT=4942.01 (S) EXISTING CONCRETE APRON EXISTING BUILDING (824 E. LINCOLN AVE.) ODELL BREWING COMPANY (800 E. LINCOLN AVE.) EXISTING OUTDOOR PATIO EXISTING PARKING LOT EXISTING OVERHEAD STRUCTURE EXISTING SIDEWALK EXISTING STORM MH EXISTING SIDEWALK EXISTING RETAINING WALL EXISTING VALLEY PAN 6' SIDEWALK EXISTING DRIVEWAY PROPOSED CONCRETE DRIVEWAY PROPOSED CONCRETE DRIVEWAY PROPOSED CONCRETE DRIVEWAY PROPOSED RETAINING WALL DRIVEWAY TO BE LOCATED IN PRIVATE ACCESS EASEMENT BY SEPARATE DOCUMENT EDGE OF UTILITY EASEMENT PER REC. NO 19900004624 EDGE OF DRAINAGE AND DETENTION POND EASEMENT PER REC. NO 19950074251 PROPOSED 20' EMERGENCY ACCESS EASEMENT AREA INLET GRATE = 4944.93 CLEAN OUT 175 LF OF 1 1 4" WATER SERVICE (SEE NOTE 7). EXISTING 15" STORM SEWER EXISTING CLEAN-OUTS EXISTING ELECTRIC VAULT CLEAN OUT CLEAN OUT AREA INLET GRATE = 4945.94 EXISTING TRANSFORMER EXISTING STORM MH RIM=4947.83 (RECORD) EX. INV IN=4943.23 (N) PROPOSED INV IN = 4943.33 (E) EX. INV OUT=4943.22 (S) EXISTING 327.12 LF OF 15" HDPE STORM SEWER S = 0.25% PROPOSED 40.23 LF OF 15" HDPE STORM SEWER @ S = 0.5% PROPOSED 15" Ø NYLOPLAST DRAIN INLET GRATE = 4945.75 INV OUT = 4943.43 PROPOSED 1.25' DEEP SWALE @ 1.5% FL SLOPE CLEAN OUT Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH C300 UTILITY PLAN 5 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R EXISTING WATER MAIN LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 3. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 4.5' MAXIMUM COVER SHALL BE 5.5' 6. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. 7. MINIMUM 1 1 4" TYPE K COPPER. 1 1 2" HDPE WILL BE CONSIDERED AS AN APPROVED ALTERNATIVE TO 1 1 4" TYPE K COPPER. IF CONTRACTOR ELECTS TO USE 1 1 2" HDPE, THEN REDUCER FROM 1 1 4" TO 1 1 2" SHALL BE LOCATED 5 FEET BEYOND THE WATER METER. SEE WATERLINE NOTE 4 ON SHEET C001 REGARDING 1 1 2" WATER SERVICES. 8. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 9. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. W G T E EXISTING STORM SEWER ST PROPOSED ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING SANITARY SEWER SS EASEMENT LINE PROPERTY BOUNDARY PROPOSED UNDERDRAIN UD EXISTING ELECTRIC E EXISTING RIGHT-OF-WAY PROPOSED 1 1/4" WATER SERVICE W EXISTING TREES PROPOSED CURB EXISTING CABLE LINE CTV EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT VAULT ELEC CONTROL IRR ELEC C S H2O S D V.P. EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING POWER POLE EXISTING VERTICAL PIPE W EXISTING ROOF DRAIN EXISTING DRY WELL RETAINING WALL DRIVEWAY TO BE LOCATED IN PRIVATE ACCESS EASEMENT BY SEPARATE DOCUMENT EDGE OF DRAINAGE AND DETENTION POND EASEMENT PER REC. NO 19950074251 PROPOSED 20' EMERGENCY ACCESS EASEMENT BY SEPARATE DOCUMENT PROPOSED 20' EMERGENCY ACCESS EASEMENT BY SEPARATE DOCUMENT 3 4 1 2 1 EDGE OF UTILITY EASEMENT PER REC. NO 19900004624 2 PROPOSED RAISED PLANTER (RE: LANDSCAPE ARCHITECT) PROPOSED 1.5' WIDE VALLEY PAN PROPOSED 1.5' WIDE VALLEY PAN 5 5 PROPOSED PLAZA (RE: LANDSCAPE ARCHITECT) EXISTING UTILITY PAD PROPOSED FENCE (RE: LANDSCAPE ARCHITECT) PROPOSED HANDICAP STALL 17' TYP. 9' TYP. PROPOSED BOULDER WALL (RE: LANDSCAPE ARCHITECT) PROPOSED 20' EMERGENCY ACCESS EASEMENT BY SEPARATE DOCUMENT PROPOSED 1.25' DEEP SWALE AT 1.5% FL SLOPE Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH C200 PAVING PLAN 4 LEGEND: BASIS OF BEARINGS: PROJECT BENCHMARK: NOTES: 1. FOR BUILDING LAYOUT, REFERENCE ARCHITECTURAL PLANS. 2. SEE GEOTECHNICAL REPORT FOR SUBGRADE PREPARATION AND PAVEMENT RECOMMENDATIONS. 3. CONTRACTOR SHALL REFER TO AND COORDINATE WITH THE LANDSCAPE DRAWINGS FOR ALL LANDSCAPE AND SITE FEATURES SUCH AS BENCHES, SEAT WALLS, LANDSCAPE WALLS, LANDSCAPE ROCK, MULCH, COLOR, STYLE, AND PATTERN OF PERMEABLE PAVERS. DEFAULT INSTALLATION OF PERMEABLE PAVERS SHALL BE A HERRINGBONE PATTERN. 4. CONTRACTOR TO REFERENCE LATEST LANDSCAPE DRAWINGS FOR PROPOSED CONCRETE COLOR, JOINT PATTERN, TEXTURE, ETC. 5. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 6. PAVEMENT MARKINGS SHALL BE PER CITY STANDARDS AND PROJECT SPECIFICATION MANUAL. 7. PERMEABLE PAVER AREAS SHALL HAVE EDGE RESTRAINTS ALONG ENTIRE PERIMETER IN ACCORDANCE WITH DETAILS AND MANUFACTURER RECOMMENDATIONS. CONCRETE CURBS AND SIDEWALKS CAN FUNCTION AS AN EDGE RESTRAINT FOR PERMEABLE PAVERS. 8. ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS STANDARDS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. (REF. LCUASS SECTION 22.6.2) 9. THE CONTRACTOR INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. 10. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. 11. CONCRETE SIDEWALKS SHALL BE 6-INCH MINIMUM THICKNESS UNLESS NOTED OTHERWISE. 12. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. BEGINNING AT THE NORTH LINE OF SUBDIVISION PLAT OF ODELL BREWING COMPANY AS BEARING SOUTH 89°11'23" WEST CITY OF FORT COLLINS BENCHMARK 3-00 LOCATED ON A PARAPET WALL AT NORTHWEST END OF THE LINCOLN AVE. BRIDGE NEAR THE NORTHWEST CORNER OF LINCOLN AVE. AND WILLOW ST. ELEVATION=4964.15 CITY OF FORT COLLINS BENCHMARK R 402 AT THE JUNCTION OF 9TH STREET AND LINCOLN AVENUE, IN THE EAST EDGE OF THE CONCRETE FOOTING FOR HIGHLINE TOWER NUMBER 29, 47.8 METERS (156.8 FEET) NORTH OF THE CENTERLINE OF THE AVENUE, 22.3 METERS (73.2 FEET) WEST OF THE CENTERLINE OF THE STREET, AND 0.2 METERS (0.7 FEET) WEST OF THE EAST EDGE OF THE FOOTING. NOTE: THE FOOTING IS 96-INCHES IN DIAMETER, 26 1/2 FEET DEEP AND SET INTO 9 FEET OF BEDROCK. ELEVATION=4939.03 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R PROPOSED PERMEABLE PAVERS PROPOSED CURB PROPOSED GRAVEL PROPOSED CONCRETE FLATWORK EXISTING CONCRETE FLATWORK PROPOSED SAW CUT 6" VERTICAL CURB 9" FLUSH CURB 1' WIDE VERTICAL CURB 1' WIDE FLUSH CURB 4 3 2 1 EASEMENTS VALLEY PAN 1' WIDE SIDEWALK CULVERT 5 E E W W W W W W W W W W W T T T T T T T T T X A C T T T T T T T T SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS M D ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST ST D D H Y D W C S W C S VAULT ELEC CONTROL IRR CONTROL IRR CONTROL IRR CONTROL CONTROL IRR IRR MH VAULT ELEC VAULT CABLE VAULT ELEC D D D C.O. E VAULT ELEC V.P. ELEC BRKR E GGG C.O. C.O. AC AC M T T T T X G G G G G G G G G G G E E E E E E E E E E E E E E X X X X X X T T T T T T T T T T T X X X T T T T T T T T T T ST ST ST ST ST W W W W W SS SS SS SS SS SS SS E E E E E EXISTING BUILDING ±2949 SF ASPHALT TO BE REMOVED ±88 SF CONCRETE TO BE REMOVED ±9 SF CONCRETE TO BE REMOVED ±99 SF CONCRETE TO BE REMOVED REMOVE GRATE TO EXISTING STORM INLET AND REPLACE WITH CLEANOUT. SEE SHEET C400. EXISTING SANITARY EXISTING 10' SIDEWALK MANHOLE EXISTING FIRE HYDRANT EXISTING GATE TO BE REMOVED EXISTING GAS LINE TO REMAIN EDGE OF EXISTING SHRUBS AC UNITS EXISTING SHRUBS TO BE REMOVED PRESERVE & PROTECT EXISTING CONCRETE PADS & TRANSFORMERS APPROXIMATE LOCATION OF EXISTING TELEPHONE LINE EXISTING GAS LINE EXISTING WATER LINE REMOVE EXISTING ELECTRICAL OUTLETS EXISTING WATERLINE VALVE EXISTING 3 4" WATER METER & CURB STOP TO BE REUSED. SEE SHEET ---- FOR FURTHER DETAIL EXISTING UNDERGROUND CABLE EXISTING UNDERGROUND ELECTRIC PRESERVE & PROTECT BOLLARDS ±365 SF CONCRETE TO BE REMOVED ±414 SF CONCRETE TO BE REMOVED APPROXIAMTELY 116' OF 3 4" WATER SERVICE TO BE ABANDON 5' FROM THE METER. (SEE SHEET ----.) EXISTING 14' ACCESS EASEMENT TO BE VACATED ±16' RETAINING WALL TO BE REMOVED EXISTING 22' ACCESS EASTMENT TO BE VACATED E. LINCOLN AVE. EXISTING INLET EXISTING POND EXISTING OUTLET STRUCTURE EXISTING STORM MH RIM=4946.15 INV IN=4942.40 (N) INV OUT=4942.33 (SW) EXISTING STORM MH RIM=4946.20 INV IN=4942.08 (N) INV IN=4942.12 (NE) INV OUT=4942.01 (S) EXISTING CONCRETE APRON EXISTING BUILDING (824 E. LINCOLN AVE.) ODELL BREWING COMPANY (800 E. LINCOLN AVE.) EXISTING OUTDOOR PATIO EXISTING PARKING LOT EXISTING OVERHEAD STRUCTURE EXISTING SIDEWALK EXISTING STORM MH HORSETOOTH HOT SAUCE (832 E. LINCOLN AVE.) PRESERVE & PROTECT EXISTING CONCRETE PAD & TRANSFORMER EXISTING RETAINING WALL TO REMAIN IN PLACE EXISTING RETAINING WALL PRESERVE & PROTECT EXISTING TREE PRESERVE & PROTECT EXISTING TREE EDGE OF UTILITY EASEMENT PER REC. NO 19900004624 EDGE OF DRAINAGE AND DETENTION POND EASEMENT PER REC. NO 19950074251 OUTDOOR PATIO EXISTING GRAVEL TO BE REMOVED ±72 SF CONCRETE TO BE REMOVED Sheet ODELL WINE PROJECT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 12 ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH C100 & DEMOLITION PLAN EXISTING CONDITIONS 3 LEGEND: G EXISTING STORM SEWER ST EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL FIELD SURVEY BY: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. CURB, GUTTER AND SIDEWALK SHALL BE REMOVED TO THE NEAREST JOINT. 7. LIMITS OF CONCRETE REPAIRS TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. CONCRETE TO BE REMOVED JOINT TO JOINT. 8. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, SIDEWALKS, CURB AND GUTTER, PRIVATE FENCES, AND ABOVE GROUND OR UNDERGROUND UTILITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 9. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ITEMS. ORIGINAL FIELD SURVEY BY: NORTHERN ENGINEERING SERVICES, INC. PROJECT NUMBER: 100-009 DATE: APRIL 17, 2008 ADDITIONAL FIELD SURVEYS: NORTHERN ENGINEERING SERVICES, INC. DATE: JANUARY 29, 2009 ADDITIONAL FIELD SURVEYS: NORTHERN ENGINEERING SERVICES, INC. DATE: AUGUST 01, 2019 EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR ELEC C S H2O S D V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING POWER POLE EXISTING VERTICAL PIPE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R W PROPOSED SAWCUT EXISTING TELEPHONE LINE T EXISTING CABLE LINE CTV EXISTING ROOF DRAIN EXISTING DRY WELL NOTES: For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 10. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 11. All recommendations of the Final Drainage Report for Odell Wine Project Dated August, 28th 2019 by Northern Engineering Services, Inc., shall be followed and implemented. 12. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 13. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 14. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 15. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 16. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 17. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 18. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 19. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 20. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 21. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 22. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 23. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 24. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 25. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 26. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 27. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 28. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 29. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 30. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 31. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 32. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: BENCHMARK #1: City of Fort Collins Benchmark 3-00 Location: On a parapet wall at the Northwest end of the Lincoln Ave. bridge near the Northeast corner of Lincoln Ave. and Willow st. Elevation= 4967.33 (NAVD88) BENCHMARK #2: City of Fort Collins Benchmark R 402 Location: At the junction of 9th street and Lincoln Ave. in the East edge of the concrete footing for highline tower number 29, 156.8ft North of the centerline of the Avenue, 73.2 ft West of the Centerline of the street, and .7 ft West of the East edge of the footing. Elevation= 4942.21 (NAVD88) Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18' Basis of Bearings North line of the Subdivision Plat of Odell Brewing Company First Replat as bearing South 89°11'23" West 33. All stationing is based on centerline of roadways unless otherwise noted. 34. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 35. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 36. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 37. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 38. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 39. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 40. Approved Variances are listed as follows: · N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. See separate Stormwater Management Plan / Erosion Control Report for Waterfield Third Filing for additional information. 17. A vehicle tracking control pad shall be installed when needed for construction equipment, including but not limited to personal vehicles exiting existing roadways. No earthen materials, i.e. stone, dirt, etc. shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpiles, staging areas, construction materials, concrete washout areas, and/or building sites. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage Report for Odell Wine Project Dated August, 28th 2019 by Northern Engineering Services, Inc., shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Waterline Notes 1. All waterline and sanitary sewer construction shall conform to the Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2,\ and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal box and tracer wire test lid per City Water Detail 25. 800 E. Lincoln Avenue Fort Collins, Colorado 80525 (970) 498-9070 SITE ENGINEER Rebecca Spears, AIA RB+B Architects, Inc. 315 E. Mountain Avenue #100 Fort Collins, Colorado 80524 (970) 484-0117 ARCHITECT SURVEYOR PLANNER/LANDSCAPE ARCHITECT SHEET INDEX I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: BENCHMARK #1: City of Fort Collins Benchmark 3-00 Location: On a parapet wall at the Northwest end of the Lincoln Ave. bridge near the Northeast corner of Lincoln Ave. and Willow st. Elevation= 4967.33 (NAVD88) BENCHMARK #2: City of Fort Collins Benchmark R 402 Location: At the junction of 9th street and Lincoln Ave. in the East edge of the concrete footing for highline tower number 29, 156.8ft North of the centerline of the Avenue, 73.2 ft West of the Centerline of the street, and .7 ft West of the East edge of the footing. Elevation= 4942.21 (NAVD88) Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) for their vertical datums. If NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) is required for any purpose, the following equation should be used: NGVD29 Unadjusted Datum (prior City of Fort Collins Datum) = NAVD88 - 3.18' Basis of Bearings North line of the Subdivision Plat of Odell Brewing Company First Replat as bearing South 89°11'23" West Original Field Survey Northern Engineering Services, INC. Project Number: 100-009 Date: April 17, 2008 Additional Field Surveys: Northern Engineering Services, INC. Date: January 29, 2009 Additional Field Survey: Northern Engineering Services, INC. Date: August 01, 2019 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: UTILITY PLANS FOR A PARCEL OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 12, TOWNSHIP 7 NORTH RANGE 69 WEST OF THE 6th P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO ODELL WINE PROJECT ENGINEER ING N O R T H E RN ENGINEER ING N O R T H E RN (MAJOR AMENDMENT) UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS----------------- Xcel Energy------------------------------------------(970) 225-7869 ELECTRIC-------- City of Fort Collins Light & Power--------------(970) 212-2900 CABLE------------- Comcast----------------------------------------------(800) 934-6489 TELECOM.--------CenturyLink------------------------------------------(970) 445-4382 WATER------------ City of Fort Collins Utilities-----------------------(970) 221-6700 WASTEWATER--City of Fort Collins Utilities-----------------------(970) 221-6700 STORMWATER- City of Fort Collins Utilities-----------------------(970) 221-6700 1 C000 COVER SHEET 2 C001 GENERAL & CONSTRUCTION NOTES 3 C100 EXISTING CONDITIONS & DEMOLITION PLAN 4 C200 PAVING PLAN 4 C300 UTILITY PLAN 6 C400 GRADING PLAN 7 C401 SUBGRADE PLAN 8 C500 SITE DETAILS 9 C501 UTILITY DETAILS 10 C600 EROSION CONTROL PLAN 11 C601 EROSION CONTROL DETAILS 12 C602 DRAINAGE EXHIBIT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Bob Tessely, PLS Northern Engineering Services, Inc. 301 N. Howes St., Suite 100 Fort Collins, Colorado 80521 (970) 221-4158