HomeMy WebLinkAboutFORT COLLINS MONTESSORI SCHOOL - SPA190003 - SUBMITTAL DOCUMENTS - ROUND 1 - LANDSCAPE PLAN (3)SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI
HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 8 SERIES 30
HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0"
POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION
SPRAY NOZZLES
HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 10 SERIES 30
HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0"
POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION
SPRAY NOZZLES
HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 12 SERIES 30
HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0"
POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION
SPRAY NOZZLES
HUNTER PROS-06-PRS30-CV WITH TORO PRECISION NOZZLE 15 SERIES 30
HUNTER PROS-06-PRS30-CV: TURF SPRAY, 30 PSI REGULATED 6.0"
POP-UP. WITH FACTORY INSTALLED DRAIN CHECK VALVE. CO-MOLDED
WIPER SEAL WITH UV RESISTANT MATERIAL. UTILIZE TORO PRECISION
SPRAY NOZZLES
HUNTER MP2000 PROS-06-PRS40-CV 40
TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40
BODY. K=BLACK ADJ ARC 90-210, G=GREEN ADJ ARC 210-270,
R=RED 360 ARC.
HUNTER MP3000 PROS-06-PRS40-CV 40
TURF ROTATOR, 6" POP-UP WITH FACTORY INSTALLED CHECK VALVE,
PRESSURE REGULATED TO 40 PSI, MP ROTATOR NOZZLE ON PRS40
BODY. B=BLUE ADJ ARC 90-210, Y=YELLOW ADJ ARC 210-270,
A=GRAY 360 ARC.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION PSI GPM RADIUS
HUNTER I-20-06-SS 45 3.00 38'
TURF ROTOR, 6.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS
STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE.
HUNTER I-20-06-SS 45 4.00 40'
TURF ROTOR, 6.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS
STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE.
HUNTER I-20-06-SS 45 6.00 43'
TURF ROTOR, 6.0" POP-UP. ADJUSTABLE AND FULL CIRCLE. STAINLESS
STEEL RISER. DRAIN CHECK VALVE. STANDARD NOZZLE.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
DRIP VALVE ASSEMBLY
HUNTER ICZ-101-25: DRIP CONTROL ZONE KIT. 1" ICV GLOBE VALVE
WITH 1" HY100 FILTER SYSTEM. PRESSURE REGULATION: 25PSI. FLOW
RANGE: 2 GPM TO 20 GPM. 150 MESH STAINLESS STEEL SCREEN.
DRIPLINE FLUSH CAP
AGRIFIM FLUSH CAP. 3/4" DRIPLINE COMPRESSION END CAP WITH
SCREW ON END.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
REMOTE CONTROL VALVE ASSEMBLY
HUNTER MODEL ICV 1", 1-1/2", 2", AND 3" PLASTIC ELECTRIC REMOTE
CONTROL VALVES, GLOBE CONFIGURATION
QUICK COUPLER VALVE ASSEMBLY
HUNTER HQ-5RC: VALVE WITH YELLOW RUBBER COVER, RED BRASS
AND STAINLESS STEEL, WITH 1" NPT INLET, 1-PIECE BODY.
ISOLATION GATE VALVE ASSEMBLY
MATCO-NORCA 514TX: 1/2"-4" BRASS GATE VALVE, FULL PORT, WITH
SOLID WEDGE. IPS. CROSS HANDLE. SAME SIZE AS MAINLINE PIPE.
MASTER VALVE ASSEMBLY
A
2
1
NORTH
0
SCALE:
15 30 60 90
1" = 30'
TFG Design, LLC
138 E 4th Street, STE #1
Loveland CO 80537
(970) 669.3737
LANDSCAPE ARCHITECTURE PLANNING
SHEET OF
SHEET NUMBER:
SHEET TITLE:
REVISIONS:
PROJECT INFORMATION:
OWNER:
DRAWN BY: dmrkp
FILE LOCATION: C:\Users\dmrkp\Dropbox\MPi Designs\Client Files\TFG Design, LLC\FTC Montessori School\1-DESIGN PHASE\Design files\IR-FTC MONTESSORI SCHOOL.dwg
PLOT DATE: 10/7/2019 3:08 PM
PROJECT NUMBER:
DATE:
PHASE:
www.tfgdesign.com
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND
SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THE
FRONTERRA GROUP AND SHALL NOT BE REPRODUCED,
PUBLISHED OR USED IN ANY WAY WITHOUT THE
P E RMISSION O F T H E L A N D S C A P E A R CHITECT.
The
Group
FronTerra
9 12
IR1.1
IRRIGATION PLAN
SPAR (SDP)
10/07/2019
177-1902FC
LARIMER
FORT COLLINS, COLORADO 80525
1109 W HARMONY RD
PRELIMINARY SPAR SITE DEVELOPMENT PLAN
FORT COLLINS MONTESSORI SCHOOL
Fort Collins, Colorado
Fort Collins Montessori School
BUCKNER-SUPERIOR 3100, NORMALLY OPEN BRASS MASTER VALVE
THAT PROVIDES DIRTY WATER PROTECTION. SIZE TO MATCH POC
REDUCED PRESSURE BACKFLOW PREVENTER
WILKINS 375B: BACKFLOW PREVENTER WITH BLOW OUT/FLUSH FITTING.
REINFORCED NYLON HOUSING AND CAST BRONZE BALL VALVES. SIZED
TO MATCH TAP & METER (RE: POC NOTE).
PEDESTAL MOUNT 2-WIRE CONTROLLER
HUNTER PED-SS-A2C-75D-SS: 75-STATION DECODER CONTROLLER IN
AN OUTDOOR STAINLESS STEEL PEDESTAL. INSTALL WITH WIRELESS
RAIN SENSOR AND SOLAR SYNC.
CREATIVE SENSOR TECHNOLOGY FSI-T
1.5-INC PVC TEE TYPE FLOW SENSOR W/SOCKET ENDS, CUSTOM MOUNTING
TEE AND ULTRA-LIGHTWEIGHT IMPELLER ENHANCES LOW FLOW
MEASUREMENT. 2 WIRE DIGITAL OUTPUT. FLOW RANGE 1.8-108 GPM.
IRRIGATION LATERAL LINE: PVC CLASS 200 SDR 21
PVC CLASS 200 IRRIGATION PIPE. ONLY LATERAL TRANSITION PIPE
SIZES 1 1/4" AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL
OTHERS BEING 1" IN SIZE.
DRIP IRRIGATION LATERAL LINE TO EMITTERS: UV RADIATION
RESISTANT POLYETHYLENE PIPE, 3/4-INCH UNLESS OTHERWISE
SPECIFIED.
DRIP IRRIGATION LATERAL LINE TO EMITTERS IN NATIVE SEED:
3/4-INCH UV RADIATION RESISTANT POLYETHYLENE PIPE TO
NETAFIM INLINE DRIP TUBING TREE RINGS AND SINGLE OUTLET
EMITTERS FOR SHRUBS
IRRIGATION MAINLINE: PVC CLASS 200 SDR 21
X-INCH UNLESS OTHERWISE NOTED.
PIPE SLEEVE: PVC SCHEDULE 40
INSTALL AS SHOWN ON DESIGN OR TWICE THE SIZE OF THE PIPE OR
WIRE RUNNING THRU IT. NO TWO PIPES OR WIRE BUNDLES SHALL
SHARE THE SAME SLEEVE.
A
IRRIGATION_SCHEDULE INSTALLATION GENERAL NOTES
1. DESIGN ASSUMES A MINIMUM DYNAMIC PRESSURE FOR THE IRRIGATION
SYSTEM ( NOT OBTAINED) OF XX PSI, AT A MAXIMUM FLOW OF 18 GPM AT THE
1-INCH POINT-OF-CONNECTION (POC). VERIFY PRESSURE AND FLOW ON SITE
PRIOR TO CONSTRUCTION. CONTACT GENERAL CONTRACTOR OR OWNER'S
REPRESENTATIVE IMMEDIATELY IF FLOW OR PRESSURE ARE LOWER THAN LISTED
ABOVE.
2. CONTRACTOR SHALL BECOME FAMILIAR WITH THE SPECIFICATIONS AND
INSTALLATION DETAILS FOR THIS AND RELATED WORK PRIOR TO
CONSTRUCTION. FOR CLARIFICATION, CONTACT IRRIGATION DESIGNER PRIOR
TO CONSTRUCTION.
2.1.UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER REQUIRED
ADJUSTMENT KEYS INCLUDING BUT NOT LIMITED TO CONTROLLER
ENCLOSURE AND BACKFLOW ENCLOSURE KEY, LOCKING VALVE BOX KEYS,
QUICK COUPLER KEYS, GATE VALVE KEY, SPRINKLER HEAD AND NOZZLE
ADJUSTMENT KEYS.
2.2. UPON FINAL ACCEPTANCE, CONTRACTOR SHALL TURN OVER SPARE
PARTS PERTAINING TO INSTALLED SYSTEM: BACKFLOW WINTERIZATION
INSERT, TWO OF EVERY HEAD AND NOZZLE (ROTOR NOZZLE TREE
INCLUDED), ONE RCV DIAPHRAGM, ETC.
3. COORDINATE UTILITY LOCATES OF UNDERGROUND UTILITIES PRIOR TO
CONSTRUCTION ("811-CALL BEFORE YOU DIG") .
4. IF DISCREPANCIES ARE NOTED IN THE FIELD BETWEEN SITE CONDITIONS
AND PROVIDED DESIGNS, CONTRACTOR SHALL NOTIFY OWNER'S
REPRESENTATIVE OR GENERAL CONTRACTOR IMMEDIATELY. DO NOT PROCEED
WITH THE INSTALLATION OF THE IRRIGATION SYSTEM IF SUCH DISCREPANCIES
IN THE FIELD AFFECT THE PROVIDED DESIGN, DETAILS, OR SPECIFICATIONS.
5. ALL IRRIGATION COMPONENTS (MAINLINE, WIRES, LATERAL LINES, ETC.)
SHALL BE INSTALLED IN LANDSCAPED AREAS WHENEVER POSSIBLE, EVEN
THOUGH SAID IRRIGATION COMPONENTS MAY BE SHOWN OUTSIDE PLANTING
AREAS FOR CLARITY.
6. AVOID CONFLICTS BETWEEN THE IRRIGATION SYSTEM, PLANTING
MATERIALS, AND ARCHITECTURAL FEATURES WHENEVER POSSIBLE.
COORDINATE POTENTIAL RELOCATION OF BOULDERS AND TREES IN TURF
AREAS WITH LANDSCAPE ARCHITECT PRIOR TO SPRINKLER LAYOUT. IF
LANDSCAPE MATERIAL CANNOT BE REOLOCATED,ADDITIONAL SPRINKLERS
MAY BE REQUIRED.
7. CROSS FITTINGS ARE NOT ALLOWED, ONLY STANDARD TEES AND
ELBOWS.
8. CONTRACTOR SHALL INSTALL NOZZLES PER PLAN, UNLESS IRRIGATED
AREA CHANGED IN SIZE OR PLANT MATERIAL TYPE CHANGES. IF NOZZLE
CHANGES ARE REQUIRED AND ARE SIGNIFICANT IN SIZE, CONTRACTOR SHALL
CONTACT IRRIGATION DESIGNER FOR APPROVAL.
9. CONTRACTOR SHALL FIELD LOCATE ANY EXISTING SLEEVES ON SITE PRIOR
TO CONSTRUCTION WITH THE AID OF THE GENERAL CONTRACTOR. MISSING
SLEEVES SHALL BE REPORTED IMMEDIATELY. NEW SLEEVES SHOWN ON PLANS
ARE REQUIRED FOR BOTH PIPING AND ELECTRICAL WIRING AT EACH
HARDSCAPE CROSSING. COORDINATE INSTALLATION OF SLEEVING WITH
OTHER TRADES. ANY PIPE OR WIRE WHICH PASSES BENEATH EXISTING
HARDSCAPE WHERE SLEEVING WAS NOT INSTALLED WILL REQUIRE HORIZONTAL
BORING BY THE IRRIGATION CONTRACTOR.
10. INSTALL ALL ELECTRICAL POWER TO THE IRRIGATION CONTROL SYSTEM IN
ACCORDANCE WITH THE NATIONAL ELECTRIC CODE AND ALL APPLICABLE LOCAL
ELECTRIC UTILITY CODES.
11. THE FOLLOWING SHOULD BE NOTED REGARDING PIPE SIZING: IF A
SECTION OF UNSIZED PIPE IS LOCATED BETWEEN THE IDENTICALLY SIZED
SECTIONS, THE UNSIZED PIPE IS THE SAME NOMINAL SIZE AS THE TWO SIZED
SECTIONS. THE UNSIZED PIPE SHOULD NOT BE CONFUSED WITH THE DEFAULT
PIPE SIZE NOTED IN THE LEGEND.
11.1. MAINLINE PIPE SIZES MAY VARY THROUGHOUT PROJECT. EACH
MAINLINE LEG IS SIZED TO ACCOMMODATE LARGEST VALVE ON THAT LEG.
STATED SIZE IN LEGEND MAY NOT BE THE LARGEST SIZE ON PLANS.
12. INSTALL THREE (3) #14 AWG CONTROL WIRES FROM CONTROLLER
LOCATION TO EACH DEAD-END OF MAINLINE FOR USE AS SPARES INCASE OF
CONTROL WIRE FAILURE. COIL 3 FEET OF WIRE IN VALVE BOX.
13. TWO-WIRE CONTROL CABLE DOES NOT REQUIRE ADDITIONAL SPARE
WIRES TO BE ROUTED WITH MAINLINE.
13.1. TWO-WIRE CONTROL SURGE ARRESTORS SHALL BE INSTALLED PER
MANUFACTURER'S RECOMMENDATIONS. ARRESTORS ARE NOT DEPICTED
ON PLANS
14. TREES IN TURF ARE NOT IRRIGATED BY DRIP SYSTEM. DRIP LATERAL
ROUTED NEAR TREES IN TURF ARE NOT TO RECEIVE DRIP IRRIGATION. TREES IN
NATIVE SEEDED AREAS ARE IRRIGATED ON DRIP SYSTEM.
15. VALVES FOR NATIVE SEEDED AREAS SHALL BE ON A SEPARATE PROGRAM.
16. NATIVE SEEDED AREAS ARE TO BE IRRIGATED WITH A BELOW GRADE
SYSTEM BUT UTILIZED FOR ESTABLISHMENT OF SEED. SYSTEM IS NOT
INTENDED TO OPERATE BEYOND ESTABLISHMENT.
17. NO IRRIGATION EQUIPMENT, INCLUDING BUT NOT LIMITED TO, MAINLINE,
VALVES, AND SPRINKLERS, SHALL BE INSTALLED WITHIN 3' OF NEW BUILDING
FOUNDATION.
EMITTER SCHEDULE
PLANT TYPE EMITTER TYPE GPH/OUTLET N0. OF EMITTERS TOTAL FLOW
GROUNDCOVER SINGLE OUTLET 1 GPH 1 1 GPH
PERENNIALS SINGLE OUTLET 1 GPH 1 1 GPH
1 GAL. SHRUB SINGLE OUTLET 1 GPH 1 1 GPH
5 GAL. SHRUB SINGLE OUTLET 1 GPH 2 2 GPH
TREE IN SHRUB BED SINGLE OUTLET 1 GPH 4-8 4-8 GPH
TREE IN NATIVE SEED INLINE DRIP* 0.6 GPH N/A N/A
NOTES:
1. MULTIPLE OUTLET EMITTERS CAN BE UTILIZED IN DENSELY PLANTED AREAS AND FOR TREES IN SHRUB
BEDS.
2. REFER TO LEGEND AND DETAILS FOR INLINE DRIP TOTALS.
SYMBOL DESCRIPTION
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE
DOWNSTREAM OF THE DOMESTIC WATER TAP AND METER AT THE
APPROXIMATE LOCATION SHOWN (REFER TO CIVIL PLANS FOR
EXACT LOCATION). INSTALL BACKFLOW PREVENTION UNIT,
MASTER VALVE ASSEMBLY, AND FLOW SENSOR AS INDICATED.
VERIFY EXACT LOCATION OF POC WITH OWNER`S
REPRESENTATIVE. VERIFY PRESSURE AND FLOW ON SITE PRIOR
TO CONSTRUCTION. CONTRACTOR TO INSTALL BACKFLOW PER
NATIONAL PLUMBERS CODE AND PER LOCAL CODE. BACKFLOW
SHALL BE TESTED UPON INSTALLATION AND ANNUALLY
THEREAFTER.
PEDESTAL MOUNT THE IRRIGATION CONTROLLER AT THE
APPROXIMATE LOCATION SHOWN. COORDINATE ELECTRICAL
POWER TO THE CONTROLLER WITH THE OWNER`S
REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THE
IRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE
FOR MAINTENANCE, AND SCREENED FROM VIEW EITHER BEHIND
ENTRY WALLS, NEXT TO BUILDINGS, OR BEHIND PLANT MATERIAL.
FINAL LOCATION TO BE APPROVED BY OWNER`S
REPRESENTATIVE. CONTROLLER TO BE INSTALLED PER NATIONAL
ELECTRIC CODE.
1
2
REFERENCE NOTES SCHEDULE
NORTH
0
SCALE:
15 30 60 90
1" = 30'
TFG Design, LLC
138 E 4th Street, STE #1
Loveland CO 80537
(970) 669.3737
LANDSCAPE ARCHITECTURE PLANNING
SHEET OF
SHEET NUMBER:
SHEET TITLE:
REVISIONS:
PROJECT INFORMATION:
OWNER:
DRAWN BY: dmrkp
FILE LOCATION: C:\Users\dmrkp\Dropbox\MPi Designs\Client Files\TFG Design, LLC\FTC Montessori School\1-DESIGN PHASE\Design files\IR-FTC MONTESSORI SCHOOL.dwg
PLOT DATE: 10/7/2019 3:08 PM
PROJECT NUMBER:
DATE:
PHASE:
www.tfgdesign.com
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS AND
SHALL REMAIN THE PROPERTY OF TFG DESIGN, LLC. - THE
FRONTERRA GROUP AND SHALL NOT BE REPRODUCED,
PUBLISHED OR USED IN ANY WAY WITHOUT THE
P E RMISSION O F T H E L A N D S C A P E A R CHITECT.
The
Group
FronTerra
8 12
IR1.0
IRRIGATION LEGEND
AND NOTES
SPAR (SDP)
10/07/2019
177-1902FC
LARIMER
FORT COLLINS, COLORADO 80525
1109 W HARMONY RD
PRELIMINARY SPAR SITE DEVELOPMENT PLAN
FORT COLLINS MONTESSORI SCHOOL
Fort Collins, Colorado
Fort Collins Montessori School