HomeMy WebLinkAboutPROSPECT AND COLLEGE HOTEL - PDP190014 - SUBMITTAL DOCUMENTS - ROUND 1 - ELEVATIONSLEVEL 01
4,996'-0"
LEVEL 02
116'-0"
LEVEL 03
126'-0"
LEVEL 04
136'-0"
LEVEL 05
146'-0"
LEVEL 06
156'-0"
ROOF
166'-0"
1 3 4 R 6 5 9 7 8
(80' MAX.)
76'-4" BUILDING HEIGHT
LEVEL 01
4,996'-0"
LEVEL 02
116'-0"
LEVEL 03
126'-0"
LEVEL 04
136'-0"
LEVEL 05
146'-0"
LEVEL 06
156'-0"
ROOF
166'-0"
O S P B A C D E F H G L K J I M T
(80' MAX.)
76'-4" BUILDING HEIGHT
ISS. #
copyright 2019
DESCRIPTION DATE
FOR REFERENCE ONLY
NOT FOR CONSTRUCTION
ARCHITECT'S PROJECT NUMBER
OWNER
ARCHITECT 4240 ARCHITECTURE INC
3507 RINGSBY COURT, SUITE #117
DENVER, CO 80216
t: 303.292.3388
9/6/2019 10:34:10 AM
A1
ELEVATIONS & WINDOW
DETAILS
21201.00
SAUNDERS FORT
COLLINS 1623 S COLLEGE HOTEL AVE
FORT COLLINS, CO
SAUNDERS COMMERCIAL
DEVELOPMENT COMPANY
S.A. MIRO
4582 S ULSTER STREET #750
DENVER, CO 80237
STRUCTURAL
ENGINEER
LEVEL 01
4,996'-0"
LEVEL 02
116'-0"
LEVEL 03
126'-0"
LEVEL 04
136'-0"
LEVEL 05
146'-0"
LEVEL 06
156'-0"
ROOF
166'-0"
8 7 9 5 6 R 4 3 1
LEVEL 01
4,996'-0"
LEVEL 02
116'-0"
LEVEL 03
126'-0"
LEVEL 04
136'-0"
LEVEL 05
146'-0"
LEVEL 06
156'-0"
ROOF
166'-0"
T M I J K L G H F E D C A B P S O
(80' MAX.)
76'-4" BUILDING HEIGHT
BUILDING FRONTAGE ON COLLEGE. AVE.
184'-0"
ISS. #
copyright 2019
DESCRIPTION DATE
FOR REFERENCE ONLY
NOT FOR CONSTRUCTION
ARCHITECT'S PROJECT NUMBER
OWNER
ARCHITECT 4240 ARCHITECTURE INC
3507 RINGSBY COURT, SUITE #117
DENVER, CO 80216
t: 303.292.3388
9/6/2019 10:33:16 AM
A2
ELEVATIONS & WINDOW
DETAILS
21201.00
SAUNDERS FORT
COLLINS 1623 S COLLEGE HOTEL AVE
FORT COLLINS, CO
SAUNDERS COMMERCIAL
DEVELOPMENT COMPANY
S.A. MIRO
4582 S ULSTER STREET #750
DENVER, CO 80237
STRUCTURAL
ENGINEER
ISS. #
copyright 2019
DESCRIPTION DATE
FOR REFERENCE ONLY
NOT FOR CONSTRUCTION
ARCHITECT'S PROJECT NUMBER
OWNER
ARCHITECT 4240 ARCHITECTURE INC
3507 RINGSBY COURT, SUITE #117
DENVER, CO 80216
t: 303.292.3388
9/6/2019 9:54:21 AM
A3
PERSPECTIVES
21201.00
SAUNDERS FORT
COLLINS 1623 S COLLEGE HOTEL AVE
FORT COLLINS, CO
SAUNDERS COMMERCIAL
DEVELOPMENT COMPANY
S.A. MIRO
4582 S ULSTER STREET #750
DENVER, CO 80237
STRUCTURAL
ENGINEER
ME ENGINEERS
14143 DENVER W PKWY, SUITE 300
GOLDEN, CO 80401
M,E,P,FP
ENGINEER
SANDERSON STEWART
425 WEST MULBERRY ST, SUITE 201
FORT COLLINS, CO 80521
CIVIL
ENGINEER
RUSSELL + MILLS
506 S COLLEGE AVE. UNIT A FORT
COLLINS, CO 80524
LANDSCAPE
ARCHITECT
t: 303.741.3737
t: 303.421.6655
t: 855.656.5255
t: 970.484.8855
GENERAL SAUNDERS CONSTRUCTION
CONTRACTOR
t: 303.699.9000
1705 17TH STREET, SUITE 350
DENVER, CO 80202
Southeast Perspective Northeast Perspective
Northwest Perspective Southwest Perspective
ISS. #
copyright 2019
DESCRIPTION DATE
FOR REFERENCE ONLY
NOT FOR CONSTRUCTION
ARCHITECT'S PROJECT NUMBER
OWNER
ARCHITECT 4240 ARCHITECTURE INC
3507 RINGSBY COURT, SUITE #117
DENVER, CO 80216
t: 303.292.3388
9/6/2019 9:53:40 AM
A4
MATERIALS BOARD
21201.00
SAUNDERS FORT
COLLINS 1623 S COLLEGE HOTEL AVE
FORT COLLINS, CO
SAUNDERS COMMERCIAL
DEVELOPMENT COMPANY
S.A. MIRO
4582 S ULSTER STREET #750
DENVER, CO 80237
STRUCTURAL
ENGINEER
ME ENGINEERS
14143 DENVER W PKWY, SUITE 300
GOLDEN, CO 80401
M,E,P,FP
ENGINEER
SANDERSON STEWART
425 WEST MULBERRY ST, SUITE 201
FORT COLLINS, CO 80521
CIVIL
ENGINEER
RUSSELL + MILLS
506 S COLLEGE AVE. UNIT A FORT
COLLINS, CO 80524
LANDSCAPE
ARCHITECT
t: 303.741.3737
t: 303.421.6655
t: 855.656.5255
t: 970.484.8855
GENERAL SAUNDERS CONSTRUCTION
CONTRACTOR
t: 303.699.9000
1705 17TH STREET, SUITE 350
DENVER, CO 80202
masonry color 1
(Norman running bond)
metal panel color 1
(concealed fastener interlocking -
chevron shape pattern)
masonry color 2
(Utility running bond)
metal panel color 1
(perforated)
metal panel color 2
(perforated)
ISS. #
copyright 2019
DESCRIPTION DATE
FOR REFERENCE ONLY
NOT FOR CONSTRUCTION
ARCHITECT'S PROJECT NUMBER
OWNER
ARCHITECT 4240 ARCHITECTURE INC
3507 RINGSBY COURT, SUITE #117
DENVER, CO 80216
t: 303.292.3388
9/6/2019 9:54:38 AM
A5
SHADOW STUDY
21201.00
SAUNDERS FORT
COLLINS 1623 S COLLEGE HOTEL AVE
FORT COLLINS, CO
SAUNDERS COMMERCIAL
DEVELOPMENT COMPANY
S.A. MIRO
4582 S ULSTER STREET #750
DENVER, CO 80237
STRUCTURAL
ENGINEER
ME ENGINEERS
14143 DENVER W PKWY, SUITE 300
GOLDEN, CO 80401
M,E,P,FP
ENGINEER
SANDERSON STEWART
425 WEST MULBERRY ST, SUITE 201
FORT COLLINS, CO 80521
CIVIL
ENGINEER
RUSSELL + MILLS
506 S COLLEGE AVE. UNIT A FORT
COLLINS, CO 80524
LANDSCAPE
ARCHITECT
t: 303.741.3737
t: 303.421.6655
t: 855.656.5255
t: 970.484.8855
GENERAL SAUNDERS CONSTRUCTION
CONTRACTOR
t: 303.699.9000
1705 17TH STREET, SUITE 350
DENVER, CO 80202
01 PDP 16 SEP 2019
9AM NOON 3PM
3/21
6/21
12/21
9/21
metal panel color 2
(mullions,fascia, metal coping)
metal panel color 1
(angled break metal window trim)
metal panel color 3
(metal coping @ masonry, rooftop mech.
screen)
Southeast Entry Northeast Entry
ME ENGINEERS
14143 DENVER W PKWY, SUITE 300
GOLDEN, CO 80401
M,E,P,FP
ENGINEER
SANDERSON STEWART
425 WEST MULBERRY ST, SUITE 201
FORT COLLINS, CO 80521
CIVIL
ENGINEER
RUSSELL + MILLS
506 S COLLEGE AVE. UNIT A FORT
COLLINS, CO 80524
LANDSCAPE
ARCHITECT
t: 303.741.3737
t: 303.421.6655
t: 855.656.5255
t: 970.484.8855
GENERAL SAUNDERS CONSTRUCTION
CONTRACTOR
t: 303.699.9000
1705 17TH STREET, SUITE 350
DENVER, CO 80202
01 PDP 16 SEP 2019
1 NORTH SCALE: 1" = 10'-ELEVATION 0"
2 WEST SCALE: 1" = 10'-ELEVATION 0"
12’-0”w
7’-0”h
(max.)
applied wall
signage location
(84 sf )
concealed fastener
metal panel color 1
metal parapet
coping
angled break metal
window trim
perforated metal
panel color 2
aluminum windows
MCM fascia @ entry
canopy
wood / composite
soffit under entry
canopy
single ply membrane
roof
covered bike parking
masonry color 2
aluminum storefront
masonry color 1
wood screen wall
wood screen wall
masonry color 1 @ enclosed
trash / utility enclosure (detailing
consistent with building)
masonry color 1 @ enclosed
trash / utility enclosure (detailing
consistent with building)
metal parapet
coping
concealed fastener
metal panel color 1
metal parapet coping
angled break metal
window trim
masonry color 1
perforated metal panel
color 2
aluminum windows
masonry color 1
(Norman running bond)
metal panel color 1
(concealed fastener interlocking -
chevron shape pattern)
masonry color 2
(Utility running bond)
metal panel color 1
(perforated)
metal panel color 2
(perforated)
metal panel color 2
(mullions,fascia, metal coping)
metal panel color 1
(angled break metal window trim)
Sign Area Allowance
• 2sf / If of building frontage
• Building Frontage = 184’
2sf * 184’ = 368 sf of allowable signage
proposed signage
• 1 - 84 sf wall applied sign (North)
• 1 - 152 sf wall applied sign (SE corner)
• 1- 100 sf (4 sided freestanding sign)
= 336 sf of proposed signage
window detail in masonry
8’-0” x 5’-0”
soldier course @
window header
aluminum window
vertical mullion
divider
perforated metal
panel screen (over v
louver)
soldier course @
window sill
window detail in metal panel
5’-0” x 5’-0”
perforated metal
panel screen (over
VTAC louver)
angled break metal
window trim
aluminum window
metal operable opaque gate
for trash / utility enclosure
West Elevation of trash / utility enclosure
North Elevation of trash /
utility enclosure
8’-0” T.O.
MASONRY
ENCLOSURE
8’-0” T.O.
MASONRY
ENCLOSURE
26’-4” MASONRY
ENCLOSURE DIMENSION
38’-8” MASONRY ENCLOSURE DIMENSION
ME ENGINEERS
14143 DENVER W PKWY, SUITE 300
GOLDEN, CO 80401
M,E,P,FP
ENGINEER
SANDERSON STEWART
425 WEST MULBERRY ST, SUITE 201
FORT COLLINS, CO 80521
CIVIL
ENGINEER
RUSSELL + MILLS
506 S COLLEGE AVE. UNIT A FORT
COLLINS, CO 80524
LANDSCAPE
ARCHITECT
t: 303.741.3737
t: 303.421.6655
t: 855.656.5255
t: 970.484.8855
GENERAL SAUNDERS CONSTRUCTION
CONTRACTOR
t: 303.699.9000
1705 17TH STREET, SUITE 350
DENVER, CO 80202
01 PDP 16 SEP 2019
1 SOUTH SCALE: 1" = 10'-ELEVATION 0"
2 EAST SCALE: 1" = ELEVATION 10'-0"
applied vertically oriented wall
signage location (48 sf )
primary freestanding
signage location
25 sf/side (4 sided = 100 sf )
12’-0” w X 4’-0”h
(7’ max. ht. )
primary freestanding
signage location
25 sf/side (4 sided = 100 sf )
Sign Area Allowance
• 2sf / If of building frontage
• Building Frontage = 184’
2sf * 184’ = 368 sf of allowable signage
proposed signage
• 1 - 84 sf wall applied sign (North)
• 1 - 152 sf wall applied sign (SE corner)
• 1- 100 sf (4 sided freestanding sign)
= 336 sf of proposed signage
masonry color 1
(Norman running bond)
metal panel color 1
(concealed fastener interlocking -
chevron shape pattern)
masonry color 2
(Utility running bond)
metal panel color 1
(perforated)
metal panel color 2
(perforated)
metal panel color 2
(mullions,fascia, metal coping)
metal panel color 1
(angled break metal window trim)
metal parapet
coping
masonry color 1
perforated metal
panel color 2
aluminum
windows
wood patio
screen wall
aluminum
storefront
masonry color 2
below storefront
concealed fastener metal
panel color 1
metal parapet coping
perforated metal panel color 1
angled break metal window
trim
MCM fascia @ entry canopy
wood / composite soffit under
entry canopy
single ply membrane roof
concealed fastener metal
panel color 1
metal parapet coping
perforated metal panel color 1
angled break metal window
trim
MCM metal panel frame
MCM metal panel frame
masonry color 1
perforated metal
panel color 1
aluminum windows
perforated metal
panel color 2
aluminum windows
aluminum storefront
MCM fascia @ entry canopy
wood / composite soffit under
entry canopy
single ply membrane roof
masonry color 2 below
storefront
window detail in masonry
8’-0” x 5’-0”
soldier course @
window header
aluminum window
vertical mullion
divider
perforated metal
panel screen (over v
louver)
soldier course @
window sill
window detail in metal panel
5’-0” x 5’-0”
perforated metal
panel screen (over
VTAC louver)
angled break metal
window trim
aluminum window
metal panel color 3 @
mechanical screen and
elevator / stair overrun
applied vertically oriented wall
signage location (104 sf )
26’-0” w X 4’-0”h
(7’ max. ht. )