Loading...
HomeMy WebLinkAboutINTRAWEST MINOR SUBDIVISION - MA180082 - SUBMITTAL DOCUMENTS - ROUND 6 - RESPONSE TO STAFF REVIEW COMMENTS1 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6689 970.224.6134 - fax fcgov.com/developmentreview September 04, 2019 Klara Rossouw Ripley Design Inc. 419 Canyon Avenue Fort Collins, CO 80521 RE: Intrawest, BDR180035 / MA180082, Round Number 5 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, please contact your Development Review Coordinator Brandy Bethurem Harras at 970.416.2744 or bbethuremharras@fcgov.com. Comment Summary: Department: Building Services Contact: Katy Hand, khand@fcgov.com Topic: Building Insp Plan Review Comment Number: 2 09/03/2019: FOR APPROVAL: Please show dimensions on the plan indicating the distance from the west (west/south) property line to the remaining drive up teller building. Please show the dimension from the protruding roof and from the inward most west wall. Demonstrating the distance between the new property line and the teller building exceeds 10ft. OR If the teller building will be closer than 10ft to the newly proposed property line (adjacent to the parking lot). How will fire separation be addressed? If the teller building is not demolished prior to the re-plat, and the building will be the wall on the newly created property line will need to be 1hr rated (with parapet) and no openings. Response: We had a survey team go out on site and shoot additional point for the overhang and the pillars of the bank teller structure. It was determined that the structure is a U occupancy, which allows a reduced setback of 5’. The overhang and the pillars exceed this distance from the proposed lot line. We are showing this on the minor amendment plans as an accurate representation of what is out there. We had a similar issue with the PUD drawing for the PFA Fire Access – the old plan that we are correcting has been scaled and adjusted to fit the drawings and therefore the surveyed points do not match what is graphically shown on the PUD. Please refer to the MA drawing for the surveyed points n relationship to the lot line. 2 Department: PFA Contact: Andrew Rosen, 970-416-2599, arosen@poudre-fire.org Topic: General Comment Number: 1 08/29/2019: FOR INFORMATION >The EAE is located correctly for Lot 1. >PFA will have comments regarding Lot 2 when development is proposed. Response: Acknowledged. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Plat Comment Number: 1 09/03/2019: FOR FINAL APPROVAL-UPDATED: Please make changes as marked. If changes are not made or you disagree with comments, please provide written response of why corrections were not made. Please provide any responses on redlined sheets and/or in response letter. Response: Corrections Made with this submission. Topic: General Comment Number: 7 09/03/2019: AMENDED PUD: Please verify that everything matches the Subdivision Plat. The Plat may change. Response: Acknowledge. Plat and PUD match Department: Zoning Contact: Missy Nelson, 970-416-2743, mnelson@fcgov.com Topic: Site Plan Comment Number: 4 09/04/2019: FOR INFORMATION ONLY - Thank you for adding these spaces. Please note the spaces will need to be marked with a vertical sign at the head of the stall. 08/06/2019: Minimum number of handicap parking spaces is 5. Response: Acknowledged. Signage will be provided