HomeMy WebLinkAboutINTRAWEST MINOR SUBDIVISION - BDR180035 - SUBMITTAL DOCUMENTS - ROUND 6 - RESPONSE TO STAFF REVIEW COMMENTS1
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6689
970.224.6134 - fax
fcgov.com/developmentreview
September 04, 2019
Klara Rossouw
Ripley Design Inc.
419 Canyon Avenue
Fort Collins, CO 80521
RE: Intrawest, BDR180035 / MA180082, Round Number 5
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, please contact your Development Review Coordinator Brandy Bethurem Harras at
970.416.2744 or bbethuremharras@fcgov.com.
Comment Summary:
Department: Building Services
Contact: Katy Hand, khand@fcgov.com
Topic: Building Insp Plan Review
Comment Number: 2
09/03/2019: FOR APPROVAL:
Please show dimensions on the plan indicating the distance from the west (west/south) property
line to the remaining drive up teller building. Please show the dimension from the protruding roof
and from the inward most west wall. Demonstrating the distance between the new property line and the
teller building exceeds 10ft.
OR
If the teller building will be closer than 10ft to the newly proposed property line
(adjacent to the parking lot). How will fire separation be addressed? If the teller building is not
demolished prior to the re-plat, and the building will be the wall on the newly created property line
will need to be 1hr rated (with parapet) and no openings.
Response: We had a survey team go out on site and shoot additional point for the overhang and the pillars of the bank teller
structure. It was determined that the structure is a U occupancy, which allows a reduced setback of 5’. The overhang and the pillars
exceed this distance from the proposed lot line. We are showing this on the minor amendment plans as an accurate representation
of what is out there. We had a similar issue with the PUD drawing for the PFA Fire Access – the old plan that we are correcting has
been scaled and adjusted to fit the drawings and therefore the surveyed points do not match what is graphically shown on the PUD.
Please refer to the MA drawing for the surveyed points n relationship to the lot line.
2
Department: PFA
Contact: Andrew Rosen, 970-416-2599, arosen@poudre-fire.org
Topic: General
Comment Number: 1
08/29/2019: FOR INFORMATION
>The EAE is located correctly for Lot 1.
>PFA will have comments regarding Lot 2 when development is proposed.
Response: Acknowledged.
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: Plat
Comment Number: 1
09/03/2019: FOR FINAL APPROVAL-UPDATED:
Please make changes as marked. If changes are not made or you disagree
with comments, please provide written response of why corrections were not
made. Please provide any responses on redlined sheets and/or in response letter.
Response: Corrections Made with this submission.
Topic: General
Comment Number: 7
09/03/2019: AMENDED PUD: Please verify that everything matches the
Subdivision Plat. The Plat may change.
Response: Acknowledge. Plat and PUD match
Department: Zoning
Contact: Missy Nelson, 970-416-2743, mnelson@fcgov.com
Topic: Site Plan
Comment Number: 4
09/04/2019: FOR INFORMATION ONLY - Thank you for adding these spaces.
Please note the spaces will need to be marked with a vertical sign at the head of the stall.
08/06/2019: Minimum number of handicap parking spaces is 5.
Response: Acknowledged. Signage will be provided