Loading...
HomeMy WebLinkAboutFORT COLLINS JEEP - FDP170035 - DOCUMENT MARKUPS - ROUND 1 - UTILITY PLANSSOUTH MASON STREET (CROSS-SECTION G) NOT TO SCALE WALK 72' R.O.W. 6' PROPOSED VERTICAL CURB & GUTTER EXISTING VERTICAL CURB & GUTTER 12' PROPOSED R.O.W. EXISTING R.O.W. CONC. SIDEWALK 5' 12' BIKE LANE LEFT TURN LANE EXISTING THRU LANE EXISTING R.O.W. THRU LANE 2.5' 12' 12' RIGHT TURN LANE 8' 2.5' 12' 60' SOUTH MASON STREET (CROSS-SECTION H) NOT TO SCALE 72' R.O.W. 6' 2.5' PROPOSED VERTICAL CURB & GUTTER 5.5' 12' PLANTING AREA PROPOSED R.O.W. EXISTING R.O.W. CONC. SIDEWALK 5' BIKE LANE 5' THRU LANE EXISTING THRU LANE EXISTING BIKE LANE EXISTING R.O.W. 2.5' 2.5' 12' 8' EXISTING WALK EXISTING VERTICAL X X X X X X X X X X X X X X X X X X X X EXIST. MEDIAN CURB (EXIST. ASPHALT ROADWAY) WEST HARMONY ROAD SOUTH MASON STREET (60' R.O.W.) (R.O.W. WIDTH VARIES) EXIST. TRAFFIC LIGHT POLE TO REMAIN EXIST. 2-STORY METAL BUILDING W/ ADD-ONS TO REMAIN (REFERENCE ARCHITECTURAL PLANS) LOT 1 PEDERSON AUTO PLAZA SUBDIVISION (EXIST. ASPHALT ROADWAY) TRANSFORT BUS STOP EXIST. BACK OF CURB BUS ROAD TO REMAIN CITY OF FORT COLLINS REC. NO. 20120033213 5040 5042 5044 5042 5042 5042 5046 5044 5044 5050 5046 5048 5046 5042 5044 5040 5044 5042 5044 5046 5046 5046 5046 5048 5046 5046 5046 X X X X X X X X X X X X X X X X X X X X MEDIAN CURB (ASPHALT) WEST HARMONY ROAD SOUTH MASON STREET (60' R.O.W.) (R.O.W. WIDTH VARIES) TRAFFIC LIGHT POLE 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 31,553 S.F. FINISHED FLOOR = 5045.9 LOT 1 PEDERSEN AUTO PLAZA SUBDIVISION 2ND FILING (ASPHALT) TRANSFORT BUS STOP BACK OF CURB BUS ROAD CITY OF FORT COLLINS REC. NO. 20120033213 SS SS S S S S S S W W W W W W W W W W S S S S S S S S S W W W W W W W W W W W W W S S S S S EXIST. METAL SHED EXIST. METAL SHED TRANSFORMER N 1434390.80 E 3116578.59 N 1434320.81 E 3116577.26 X X X X X X X X X X X X X X X X MEDIAN CURB (ASPHALT) WEST HARMONY ROAD SOUTH MASON STREET (60' R.O.W.) (R.O.W. WIDTH VARIES) 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 31,553 S.F. FINISHED FLOOR = 5045.9 LOT 1 PEDERSEN AUTO PLAZA SUBDIVISION 2ND FILING (ASPHALT) TRANSFORT BUS STOP CITY OF FORT COLLINS REC. NO. 20120033213 5040 5042 5044 5042 5042 5042 5046 5044 5044 5050 5046 5048 5046 5042 5044 5040 5044 5042 5044 5046 5046 5046 5046 5048 5046 5046 5046 SS SS S S S S S S W W W W W W X X X X X X X X X X X X X X X X X X X X 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 31,553 S.F. FINISHED FLOOR = 5045.9 LOT 1 PEDERSEN AUTO PLAZA SUBDIVISION 2ND FILING CITY OF FORT COLLINS REC. NO. 20120033213 SS SS S S S S S S W W W W W W W W W W S S S S S S S S W W W W W W W W W W W W W S S S S S OIL AND SAND INTERCEPTOR (SEE DETAIL THIS SHEET) 6" - 90° BEND FIRELINE 6" WET TAP W/ TB W W W W S S S S S S S S S S S S S M S S S S S S S S W W W W W W W 4 EX. STREET LIGHT TO BE RELOCATED W W W W W W W W W W W W W W W W W W W W W W W W S S S S S S S SOUTH MASON STREET 60' EXISTING R.O.W. 72' PROPOSED R.O.W. 15.5' 8.5' BEGIN CONSTRUCTION MATCH EXIST. C&G N 1434389.88 E 3117026.69 END CONSTRUCTION MATCH EXIST. C&G N 1433898.76 E 3116977.24 WEST HARMONY ROAD 7.3' ASPHALT PAVEMENT 4 0+00 1+00 2+00 3+00 4+00 5+00 5+41 BP: 0+00.00 EP: 5+41.15 PI: 0+04.06 PI: 0+24.23 PI: 0+36.74 PI: 1+12.99 PI: 5+11.41 PI: 2+31.02 PI: 3+09.29 PC: 4+69.65 PT: 5+11.31 STA: 4+50.00 / 2.00' (R) ELEV: 5038.32 FL STA: 4+00.00 / 2.00' (R) STA: 3+50.00 / 2.00' (R) ELEV: 5038.69 FL ELEV: 5039.17 FL STA: 3+00.00 / 1.99' (R) ELEV: 5039.68 FL STA: 2+50.00 / 1.99' (R) ELEV: 5040.13 FL STA: 2+00.00 / 2.00' (R) ELEV: 5040.43 FL STA: 1+50.00 / 2.00' (R) ELEV: 5040.68 FL EXIST. LIP OF PAN STA: 1+12.99 / 2.00' (R) ELEV: 5040.90 FL STA: 0+35.63 / 2.00' (R) ELEV: 5041.46 FL 4 STA: 4+69.60 / 2.00' (R) 0+07 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 0+74 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 SECTION DATA 2+00 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 SECTION DATA PROPOSED R.O.W. PROPOSED R.O.W. PROPOSED R.O.W. 5041.80 5041.73 5041.80 5041.82 5042.56 5042.29 5041.50 5041.42 5041.70 5041.36 5042.59 5041.79 5044.25 5042.01 5044.45 5042.76 5044.60 5042.87 5040.85 5040.76 5041.26 5040.60 5043.24 5042.57 5044.35 5043.42 3+18 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 4+00 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 SECTION DATA 4+69 5035 5040 5050 5035 5040 5050 -20 -10 0 10 20 30 40 SECTION DATA PROPOSED R.O.W. PROPOSED R.O.W. PROPOSED R.O.W. 5040.06 5040.37 5039.93 5041.27 5039.66 5042.66 5040.14 5043.66 5043.58 5044.12 5043.89 5044.56 5044.19 5039.56 5039.39 5039.34 5040.29 5038.86 5041.09 5039.34 5041.77 5043.04 5042.37 5043.27 5043.21 5043.50 X X X X X X X X X X X 6' 11' 21' 15' U.E. REMOVE EXISTING TREE RELOCATED "BUS STOP" SIGN R10' R25' SS SS S S S S S S S S S W W W W W W W W W W W W W W S S S S S S S S S S S S W W W W REMOVE AND RELOCATE STREET LIGHT CONCRETE SIDEWALK 0+00 1+00 1+53 STA: 0+12.47 / 2.00' (L) ELEV: 5046.17 STA: 0+16.34 / 2.73' (L) ELEV: 5046.14 STA: 0+45.35 / 12.26' (L) ELEV: 5045.95 STA: 0+50.03 / 13.01' (L) ELEV: 5045.92 STA: 0+95.53 / 13.00' (L) ELEV: 5044.94 STA: 0+99.64 / 12.43' (L) ELEV: 5044.82 STA: 1+22.96 / 5.79' (L) ELEV: 5044.15 STA: 1+32.00 / 7.65' (L) ELEV: 5044.28 STA: 1+41.07 / 26.43' (L) ELEV: 5045.13 N 1433890.51 E 3116595.07 N 1433895.00 E 3116747.70 ONLY ONLY EXIST. BIKE LANE STRIPE TO REMAIN EXIST. STOP BAR TO REMAIN 12' 12.3' 12' 120' 150' 16.5' 8.5' ±13.4' EXIST. BIKE LANE SIGN TO BE RELOCATED EXISTING STOP BAR STRIPE TO BE EXTENDED TO NEW LIP OF PAN PROPOSED PEDESTRIAN CROSS WALK STRIPING EXISTING DOUBLE YELLOW STRIPING TO BE REMOVED EXIST. BIKE LANE STRIPE TO REMAIN SOUTH MASON STREET EXIST. TRAFFIC SIGNAL POLE TO REMAIN EXIST. R.O.W. PROPOSED R.O.W. EXIST. CURB, GUTTER, & WALK EXIST. PEDESTRIAN SIGNAL BUTTON & POST TO BE RELOCATED 4 2 4 6 1 EXIST. BIKE LANE STRIPE TO BE REMOVED EXIST. R.O.W. "HANDICAP ACCESS LOCATED ON W. HARMONY ROAD" SIGN 10 5' 3 3 3 MATCH EXIST. DBL YELLOW STRIPING EXIST. BIKE LANE STRIPE TO BE REMOVED ±12' EXISTING TURNING LANE STRIPING TO BE REMOVED SOUTH MASON STREET ONLY ONLY 8 9 9 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 10 FORT COLLINS JEEP FIRE LANE SIGNAGE & STRIPING PLAN TWD 11/20/2017 1" = 30' WLB 16-018 C-12 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 M W W W W W W W 4 X X X X X X X X X X X X X X X X SS SS S S S S S S W W W W W W W W W W S S S S S S W W W W W W W W W W W W W S S S S S ONLY ONLY . .. . .. . . . . . .. ... . . . .. . .. .... ..... . .. . .. . ..... . . . ... . .. ... .. .. ........ .. ..... . . ... .. .. . . . ... .. . . .... . . . ..... ... ..... ... ... ... . .. . . . ... . . . .. ... .. ...... ... ...... . . . .... . . . . .................................... ...... . ..... . .... . ........ . ...... ........ . .......... . .... . .......... . ... . . . ... ............ ........ .. ... . .... . . .. .. .. . .. ............... .. . .. . . .. . . . . . .. . .. ..... . ..... .. ..... . ..... .. .... .. .. . . .. . . . .. . .... . . .. . A 0.22 0.93 1.16 E 0.39 N/A N/A F 0.42 N/A N/A G 0.56 N/A N/A C 1.72 0.89 B 1.12 0.33 0.89 1.11 . . .. . . ... D 0.15 N/A N/A .... . .. .. . ... . .. .. . ......... . . . . . . .. . ... . .... . ... . .. . .. . . . . . .. . .. . ... . ...... . ... . . . . . . . . . . .. . .. . . . .. . .. . .. .... . 5045 5043 5044 5045 5044 5046 5045 5046 5047 5045 5044 5041 5042 5040 5045 5039 5041 5042 5043 5044 5045 5046 1 2 3 5045 5045 5043 5043 5044 5044 5046 5046 5040 5039 5039 5041 5042 4.43% 2.63% 3.14% 2.44% 1.56% 1.10% 1.63% 1.66% 4.51% 5045 5044 5045.59 FL 5045.07 FL 5044.49 FL 5044.42 FL 5043.76 FL 5044.12 FL 5043.59 FL 5043.3 FL 5043.48 FL 5043.7 FL 5043.9 FL 5043.4 FL 5043.95 FL 5044.63 FL 5044.05 FL 5044.18 FL 5042.37 FG 5041.58 FG WQ RELEASE STRUCTURE WQ RELEASE STRUCTURE WQ RELEASE STRUCTURE 6" 90° BEND 6" - TEE 6"-90° BEND 6" CLEANOUT 6" - 11.25° Bend 6" - Tee and 6" - 11.25° Bend 15 LF~ 6" HDPE 100 LF~ 6" HDPE 100 LF~ 6" HDPE 135 LF~ 6" HDPE 16 LF~ 6" HDPE 8 LF~ 6" 6" HDPE PIPE 43 LF~ 6" HDPE 99 LF~ 6" HDPE 15 LF~ 6" HDPE 31 LF~ 6" HDPE 113 LF~ 6" HDPE 4" CLEANOUT 4" CLEANOUT 26 LF~ 4" A-2000 SLOTTED PIPE 90 LF~ 4" A-2000 SLOTTED PIPE 88 LF~ 4" A-2000 SLOTTED PIPE 62 LF~ 4" A-2000 SLOTTED PIPE 5047.2 EOA 5045.76 FL 5045.10 FL 5044.52 FL 5042.36 FL ??? FG ??? FG 5045.97 FL 5044.54 FL 5044.88 FG 5044.78 FL 5045.04 FL 5045.88 FG 5045.90 FG 18 LF~ 4" A-2000 SLOTTED PIPE 18 LF~ 4" A-2000 SLOTTED PIPE WQ/BIORETENTION BASIN A VOLUME REQUIRED = 0.006 AC-FT VOLUME PROVIDED = 0.006 AC-FT WQ/BIORETENTION BASIN B VOLUME REQUIRED = 0.009 AC-FT VOLUME PROVIDED = 0.009 AC-FT WQ/BIORETENTION BASIN C VOLUME REQUIRED = 0.042 AC-FT VOLUME PROVIDED = 0.042 AC-FT 0.39% 0.04% 0.49% 0.50% 0.43% 0.46% 1.85% 1.59% 1.63% 1.67% 0.46% 0.42% 0.03% 1.26% 0.31% 0.37% 0.61% 1.00% Runoff Analysis Data Table Basin ID C2 C100 Q2 (cfs) Q100 (cfs) A 0.87 0.95 0.53 2.02 B 0.83 0.92 0.76 2.94 C 0.80 0.89 3.33 12.96 PROPOSED 15' TYPE R INLET PROPOSED 4' DIA. STORM MANHOLE CONNECT AND OUTLET TO EXISTING STORM SEWER EXISTING STORM SEWER REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R FORT COLLINS JEEP DRAINAGE PLAN TWD 11/20/2017 1" = 30' MSG 16-018 C-19 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 30 60 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION DRAINAGE LEGEND BASIN NAME 2yr C VALUE BASIN ACREAGE 100yr C VALUE 5820 5820 EX. MAJOR CONTOUR EX. MINOR CONTOUR PR. MAJOR CONTOUR PR. MINOR CONTOUR PROPOSED BASIN BOUNDARY LINE 1 BASIN AREA 2yr 100yr PR. STORM EX. STORM BASIN LABEL DESIGN POINT PROPOSED CONCRETE Text Over Text 12/27/17 **All circled are line over text, except as noted.** C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 30 60 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' SIGNAGE AND STRIPING LEGEND: 1 STOP BAR - PRE-FORMED 90 MIL THERMOPLASTIC 3 4" WIDE PAINTED SOLID WHITE EDGE LINE 6" WIDE SOLID WHITE TURNING LANE LINE 6" WIDE DASHED WHITE TURNING LANE LINE 4 4" WIDE DOUBLE YELLOW CENTERLINE STRIPING 5 "NO PARKING" SIGN (R, L, OR D) 6 PEDESTRIAN CROSS WALK - PRE-FORMED 90 MIL 2 THERMOPLASTIC 7 8 "NO PARKING FIRE LANE SIGN" 9 CURB PAINTED RED "FIRE LANE" R7-1 10 "HANDICAP ACCESS ON W. HARMONY ROAD" NOTE: SEE SHEET C-11 FOR SOUTH MASON STREET AND WEST HARMONY ROAD ROADWAY SIGNAGE & STRIPING PLAN. Line Over Text Line Over Text 12/27/17 15-94 SS SS WEST HARMONY ROAD (R.O.W. WIDTH VARIES) EXIST. "STOP HERE ON RED" SIGN TO BE RELOCATED EXIST. STREET LIGHT WITH "40 MPH" SIGN TO BE RELOCATED EXIST. PEDESTRIAN CROSSING AHEAD SIGN TO REMAIN EXIST. STREET LIGHT WITH "RAIL ROAD CROSSING" SIGN TO REMAIN EXIST. BUS STOP SIGN TO BE RELOCATED EXIST. TRAFFIC SIGNAL POLE TO REMAIN ALL EXIST. W. HARMONY ROAD STRIPING TO REMAIN LOCATION OF RELOCATED "BUS STOP" SIGN 2 1 FORT COLLINS JEEP ROADWAY SIGNAGE & STRIPING PLAN TWD 11/20/2017 -1" = 20' WLB 16-018 C-11 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 20 40 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' SIGNAGE AND STRIPING LEGEND: 1 STOP BAR - PRE-FORMED 90 MIL THERMOPLASTIC 3 4" WIDE PAINTED SOLID WHITE EDGE LINE 6" WIDE SOLID WHITE TURNING LANE LINE 6" WIDE DASHED WHITE TURNING LANE LINE 4 4" WIDE DOUBLE YELLOW CENTERLINE STRIPING 5 "NO PARKING" SIGN (R, L, OR D) 6 PEDESTRIAN CROSS WALK - PRE-FORMED 90 MIL 2 THERMOPLASTIC 7 8 "NO PARKING FIRE LANE SIGN" 9 CURB PAINTED RED "FIRE LANE" R7-1 10 "HANDICAP ACCESS ON W. HARMONY ROAD" Line Over Text Line Over Text 12/27/17 15-94 2.00% WEST HARMONY ROAD (R.O.W. WIDTH VARIES) SOUTH MASON STREET (EX. 60' R.O.W.) N85°46'32"E 12.47' N88°30'17"E 125.18' N88°51'35"E 15.06' RELOCATED STREET LIGHT REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R FORT COLLINS JEEP BUS STOP PLAN TWD 11/20/2017 1" = 20' JLC 16-018 C-10 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 20 40 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION BUS STOP DETAIL REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Varies CONCRETE BUS PAD - ATTACHED Street Do not construct in wheel lane. 1/2" Expansion Joint Material (typical) Attached Sidewalk (width variable) 10" min. 2" 11'-0" 2'-0" 6" Thick Curb ASPHALT A A Lip F BOC BOW Existing 2'-0" Gutter 1/2" Pre-formed Sealed Expansion Joint Material 50'-0" min Contraction Joint 10'-0" Flow Line SECTION A-A (Typ) Existing Sidewalk Taper in accordance with the Table below. NOTE: 1. Length of bus pad varies as directed by the Local Entity. 2. All pads shall be a minimum of 10" thick concrete. 12'-0" or Lane Width 2'-0" CONCRETE BUS PAD - DETACHED Concrete in wheel lane. Do not construct 6" 1/2" Expansion Joint Material (typical) L T.C. F Lip BUS BAY TRANSITION LENGTHS Detached Sidewalk SPEED LIMIT LEAD IN LENGTH (Li) (FT.) LEAD OUT LENGTH (Lo) (FT.) <35 60 60 40 100 70 45 150 80 50 200 90 55 250 100 (width variable) Lo 15' R Li FL * Joints 15' R Provide Curved Connections R=15' The Local Entity Transit Authority shall specify this length. * BUS BAY BUS STOP L 2'-0" 6" 10'-0" min. 10'-0" 2'-0" Varies Street 12'-0" or Lane Width Concrete FL T.C. Lip 10'-0" min. 10'-0" 2'-0" 12/27/17 **All circled are line over text.** 15-94 5038.81 5038.92 5038.68 5039.38 5038.47 5040.10 5038.94 5040.85 5040.42 5041.57 5041.98 CONC SW 8' CONC. SIDEWALK 8' CONC. SIDEWALK 6 STEPS 4:1 -2.00% -2.00% 5038.30 FL 5038.69 FL 5039.49 FL EL: 5040.00 EXIST LIP OF PAN EL: 5040.15 BACK SW -2.55% 5043.46 FL EL: 5039.5 EXIST LIP OF PAN EL: 5039.35 BACK SW -2.20% 5042.84 FL REPLACE ASPHALT PAVEMENT. EL: 5038.47 EXIST LIP OF PAN EL: 5038.94 BACK SW 5042.08 FL REPLACE ASPHALT PAVEMENT. REPLACE ASPHALT PAVEMENT. 13.5' 13.5' 6.6' NOTE: NEW ASPHALT PAVEMENT SHALL MATCH EXIST PAVEMENT SECTION DEPTH TO SUBGRADE. 5043.44 TS 5043.44 FL SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' LANDSCAPE WALL -2.00% -2.28% -0.85% -2.28% -0.85% -3.98% -0.84% -2.54% 4 N 1433898.69 3+00 4+00 5+00 PI: 5+11.41 PI: 3+09.29 PC: 4+69.65 PT: 5+11.31 STA: 3+18.30 STA: 4+00 STA: 4+69.22 PROPOSED R.O.W. EXIST. R.O.W. CONC. SIDEWALK STA: 4+00.00 / 2.00' (R) ELEV: 5038.69 FL STA: 4+69.22 / 2.00' (R) ELEV: 5038.30 FL STA: 3+18.30 / 2.00' (R) ELEV: 5039.49 FL 5044 5040 5042 5040 5040 5044 5042 R=26.94' L=41.66' Δ=88°35'00" S89°38'10"W 0.10' 8' EDGE OF EXIST LIP SOUTH MASON STREET Know what'sbelow. Call before you dig. R FORT COLLINS JEEP MASON STREET CROSS SECTIONS TWD 11/20/2017 1" = 10' NRM 16-018 C-9.2 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 10 20 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Text Over Text 15-94 12/27/17 **All circled are line over text, except as noted.** 5044.58 5043.83 5044.79 5044.11 EXIST CONC SW 8' CONC. SIDEWALK 4:1 ASPH PVMT 4:1 5041.65 FL 5041.12 FL 5040.43 FL -2.00% EL: 5041.82 MEET & MATCH EXIST LIP OF PAN EL: 5042.26 BACK SW -6.22% EL: 5041.36 BACK SW EL: 5041.82 BACK SW EL: 5042.02 BACK SW EL: 5040.74 EXIST LIP OF PAN EL: 5042.71 BACK SW 5043.79 FL -2.86% NOTE: NEW ASPHALT PAVEMENT SHALL MATCH EXIST PAVEMENT SECTION DEPTH TO SUBGRADE. REPLACE ASPH PVMT REPLACE ASPHALT PAVEMENT. 3.2' 6.8' -2.00% 8.33% 10' ASPH PVMT ASPH PVMT -2.0% SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' SCALE: HORIZONTAL 1"=10' VERTICAL 1"= 5' -2.05% -0.85% -2.05% -0.85% 0.66% 60' EXISTING R.O.W. 72' PROPOSED R.O.W. N 1434393.94 E 3117026.80 0+00 1+00 2+00 BP: 0+00.00 PI: 0+04.06 PI: 0+24.23 PI: 0+36.74 PI: 1+12.99 PI: 2+31.02 STA: 0+06.81 STA: 0+73.69 STA: 2+00 PROPOSED R.O.W. EXIST. R.O.W. STA: 2+00.00 / 2.00' (R) ELEV: 5040.43 FL STA: 0+73.69 / 2.00' (R) ELEV: 5041.12 FL STA: 0+06.81 / 2.00' (R) ELEV: 5041.65 FL 5042 5044 5044 5042 5044 S01°34'26"W 4.06' S03°19'09"W 20.17' S01°22'45"W 12.51' S06°04'20"W 76.26' 10' 15' U.E. 2.00% 5041.8 FG 5042.02 FG 5042.0 FG SOUTH MASON STREET EDGE OF EXIST LIP REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE Know what'sbelow. Call before you dig. R FORT COLLINS JEEP MASON STREET CROSS SECTIONS TWD 11/20/2017 1" = 10' NRM 16-018 C-9.1 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 10 20 BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' 12/27/17 **All circled are line over text.** 15-94 ELEV: 5038.30 FL STA: 5+11.45 / 2.00' (R) ELEV: 5039.41 FL KENSINGTON DRIVE S03°19'09"W 20.17' S06°04'20"W 76.26' R=26.94' L=41.66' Δ=88°35'00" S89°38'10"W 0.10' S01°34'26"W 4.06' S01°22'45"W 12.51' S01°03'05"W 118.03' S05°48'54"W 78.27' S01°03'05"W 160.36' EXIST. LIP OF PAN EXIST. LIP OF PAN EXIST.TRAFFIC SIGNAL POLE TO REMAIN EXIST. TRAFFIC SIGNAL CONTROL BOXES LANDSCAPE WALL LANDSCAPE WALL STORM SEWER INLET EXIST. GROUND @ PROPOSED LIP OF GUTTER SCALE: HORIZONTAL 1"=20' VERTICAL 1"= 2' MASON STREET PROFILE 5035 5040 5050 5035 5040 5050 0+00 1+00 2+00 3+00 4+00 5+00 5+25 -0.90% -0.50% -0.70% -0.66% -0.50% -0.60% -0.90% -1.01% 0.00% 0.50% 3.00% PVI STA = 0+05.00 ELEV = 5041.84 PVI STA = 1+00.37 ELEV = 5041.17 PVI STA = 1+50.51 ELEV = 5040.84 PVI STA = 2+00.23 ELEV = 5040.60 PVI STA = 2+50.55 ELEV = 5040.29 PVI STA = 3+00.78 ELEV = 5039.84 PVI STA = 3+80.67 ELEV = 5039.03 PVI STA = 4+30.79 ELEV = 5038.58 PVI STA = 4+55.67 ELEV = 5038.46 PVI STA = 4+67.11 ELEV = 5038.46 PVI STA = 4+75.54 ELEV = 5038.50 PVI STA = 5+11.59 ELEV = 5039.58 -0.90% -0.50% -0.70% -0.66% -0.50% -0.60% -0.90% -1.01% 0.00% 0.50% 3.00% PVI STA = 0+05.00 ELEV = 5041.84 PVI STA = 1+00.37 ELEV = 5041.17 PVI STA = 1+50.51 ELEV = 5040.84 PVI STA = 2+00.23 ELEV = 5040.60 PVI STA = 2+50.55 ELEV = 5040.29 PVI STA = 3+00.78 ELEV = 5039.84 PVI STA = 3+80.67 ELEV = 5039.03 PVI STA = 4+30.79 ELEV = 5038.58 PVI STA = 4+55.67 ELEV = 5038.46 PVI STA = 4+67.11 ELEV = 5038.46 PVI STA = 4+75.54 ELEV = 5038.50 PVI STA = 5+11.59 ELEV = 5039.58 PROPOSED GROUND @ PROPOSED LIP OF GUTTER 5041.80 5041.33 5041.52 5041.69 5041.18 5041.46 5040.85 5041.26 5040.60 5041.15 5040.30 5041.85 5039.85 5039.96 5039.34 5040.29 5038.86 5039.97 5038.49 5039.22 5039.23 5039.79 5039.79 FORT COLLINS JEEP MASON STREET WIDENING PLAN TWD 11/20/2017 1" = 20' WLB 16-018 C-8 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 Feet 0 20 40 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). NOTE: SEE SHEET C-11 FOR E. MASON STREET SIGNAGE AND STRIPING PLAN. 12/27/17 **All circled are line over text, except as noted.** Text Over Text Text Over Text Text Over Text Text Over Text 15-94 Text Over Text Text Over Text 67.7' MEDIAN CURB (ASPHALT) WEST HARMONY ROAD SOUTH MASON STREET (R.O.W. WIDTH VARIES) TEL. TRANSFORT BUS STOP EX. 8" WATER EX. 8" SANITARY 158 LF ~ 6" DIP 100 LF ~ 6" PVC CORP STOP CURB STOP 135 LF~TYPE ~ 1 1/2" TYPE 'K' COPPER 1-1/2" METER 19 LF ~ 6" DIP 71 LF ~ 6" PVC 100 LF ~ 6" PVC 6" SWIVEL TEE 6" PLUG W/ TB 30 LF ~ 6" DIP 6" SEWER SERVICE 6" SEWER SERVICE 115 LF ~ 6" PVC "BUS STOP" EX. TRAFFIC LIGHT POLE TO REMAIN EX. INLET GRATE EX. TRANSFORMER BIKE RACK (4) EXIST. WATER METER TO BE RECYCLED EXIST. FIRE HYDRANT TO BE RELOCATED EX. SEWER SERVICE TO BE ABANDONED IN PLACE EX. 10" AC WATER EX. 12 " STORM 15' U.E. EX. COMMS 15' U.E. EXIST. 5' U.E. 20' EMERGENCY ACCESS ESMT. RELOCATED STREET LIGHT 4 10' Type R Inlet N=1433933.28 E=3117002.26 INV. IN = 5036.91 Type 13 Inlet w/ Solid Cover N=1433933.28 E=3117013.60 Type C Outlet Structure N=1433985.53 E=3116858.01 INV. OUT = 5039.70 6" Cleanout N=1434094.50 E=3116645.37 INV. = 5041.77 Type C Outlet Structure N=1434194.50 E=3116662.07 INV. OUT = 5041.70 Type C Outlet Structure N=1434051.02 E=3116661.87 INV. OUT = 5040.80 6" - 90° Bend N=1434194.50 E=3116645.37 INV. = 5042.27 6" - Tee N=1434051.22 E=3116645.37 6" - 90° Bend N=1433952.53 E=3116645.37 INV. = 5041.06 6" - 11.25° Bend N=1433933.28 6" - Tee and E=3116969.86 6" - 11.25° Bend N=1433952.53 E=3116858.01 INV. = 5040.0 100LF ~ 6" HDPE SD 113LF 6" ~ 6" SD HDPE SD 6" Cleanout N=1433952.53 E=3116745.37 INV. = 5040.56 SEE SHEET C-10 FOR DETIALS SEE SHEET C-10 FOR DETAILS SEE SHEET C-10 FOR DETAILS 6" GV 5 LF~6" DIP 8' 3' RELOCATED FIRE HYDRANT EX. STORM INLET TO BE REPLACED :,7+ ‘0$1+2/( INV. OUT SW (12") = 5036.89 SEWER SERVICE TO BE ABANDONED AT MANHOLE RELOCATE EX. SIGN EX. STORM MANHOLE INV. IN NE (12") = 5035.96 ,19,11:   “ INV. OUT SW = 5032.51 EX. SAN. MANHOLE INV. OUT N = 5031.41 EX. SAN. MANHOLE INV. IN S = 5031.18 INV. IN E = 5031.20 INV. OUT N = 5031.03 EX. SAN. MANHOLE INV. IN S = 5031.00 INV. OUT NW = 5030.90 6" SERVICE INV. = 5031.27± VEHICLE STORAGE CUSTOMER EMPLOYEE EMPLOYEE VEHICLE DISPLAY CUSTOMER 4"Ø X 30" H, PIPE BOLLARDS, FILL WITH CONC. CAP AND PAINT, TYP. INSTALL @ 6' 0.C. 4" PVC STORM DRAIN CLEANOUT 4" PVC STORM DRAIN CLEANOUT 2' WIDE CURB-CUT 2' WIDE CURB-CUT 4" PVC STORM DRAIN CLEANOUT 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE 4" PVC STORM DRAIN CLEANOUT 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 15' DRAINAGE ESMT. 15' DRAINAGE ESMT. 15' DRAINAGE ESMT. 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE CONNECT TO EXIST. 8" WATERLINE WITH WET TAP 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE N 1434390.80 E 3116578.59 N 1434389.41 E 3117002.13 N 1433925.66 N 1433912.65 E 3116993.62 E 3116980.38 N 1433909.92 E 3116607.92 N 1434133.98 E 3116612.20 N 1434133.98 E 3116607.20 N 1434215.26 E 3116608.75 N 1434215.35 E 3116603.75 6" CLEAN-OUT N 1434336.00 E 3116767.37 6" CLEAN-OUT N 1434336.00 E 3116838.16 6" CLEAN-OUT N 1434336.00 E 3116938.16 6" CLEAN-OUT N 1434221.04 E 3116772.37 10' (ASPHALT PARKING LOT) 99LF ~ 6" HDPE SD 135LF ~ 6" HDPE SD 16LF ~ 6" HDPE SD 43LF ~ 6" HDPE SD 100LF ~ 6" HDPE SD 17LF ~ 6" HDPE SD 33LF ~ 6" HDPE SD 11LF ~ 6" HDPE SD 17LF ~ 6" HDPE SD 20' W.L. ESMT. 15' U.E. BNSF RAIL-ROAD R.O.W. 100' (ASPHALT PARKING LOT) (ASPHALT PARKING LOT) CONC. DRAINAGE CHANNEL Feet 0 30 60 FORT COLLINS JEEP OVERALL UTILITY PLAN TWD 03/15/2017 1" = 30' JLC 16-018 C-7 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE PROPERTY LINE LOT / TRACT LINE LEGEND: S S W W EXISTING SANITARY LINE W/ MH EXISTING STORM LINE W/ MH EXISTING WATER LINE EXISTING STORM AREA INLET EXISTING FIRE HYDRANT EXISTING WATER VALVE D Y H EXISTING STORM TYPE 'R' INLET RIGHT-OF-WAY E E EXISTING ELECTRIC LINE G G EXISTING GAS LINE X X EXISTING FENCE LINE 5530 PROPOSED CONTOUR 5530 EXISTING CONTOUR S S PROPOSED SANITARY SEWER W/ MH PROPOSED STREET SIGN PROPOSED STORM SEWER W/ MH W W PROPOSED WATER LINE PROPOSED FIRE HYDRANT CTV EXISTING CATV LINE CENTERLINE R.O.W. EXISTING CONCRETE PROPOSED EASEMENT LINE EXISTING EASEMENT LINE PROPOSED WATER VALVE PROPOSED WATER FITTINGS 4 5 PROPOSED TYPE 'R' INLET PROPOSED FLARED END SECTION EXISTING RIGHT-OF-WAY PROPOSED STREET LIGHT D S COM COM EXISTING COMMUNICATION LINE PROPOSED LANDSCAPE PROPOSED ASPHALT PROPOSED CONCRETE SIDEWALK REPAIR NOTE: ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. OIL AND SAND INTERCEPTOR Know what'sbelow. Call before you dig. R BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' STREET CUT NOTE: LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 15-94 Does not match the Subdivision Plat. Line Over Text Line Over Text 12/27/17 W W W W S S S S S S W W W W W W W W W W W W W S S S S S 4 5045 5044 5046 5045 5043 5044 5045 5044 5045 5045 5045 5040 5041 EXIST. METAL SHED EXIST. METAL SHED SSA 30' X 60' VT 131 LF SF RS LOC CWA SF SF SF SF LOC LOC LOC 76 LF SF 271 LF SF SF SF SF SF SF SF SF SF SF SF 340 LF SF RS RS IP RS RS SF SF SF SF SF SF CF 225 LF RS RS RS RS RS SF SF SF SF SF SF SF SF 27 LF SF 342 LF SF 41 LF SF IP PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS PS N 1434390.80 E 3116578.59 N 1434320.81 E 3116577.26 N 1434215.35 E 3116603.75 N 1434215.26 E 3116608.75 N 1434133.98 E 3116607.20 N 1434133.98 E 3116612.20 N 1433909.92 E 3116607.92 N 1433912.65 E 3116980.38 N 1433925.66 E 3116993.62 N 1434389.41 E 3117002.13 3.0% 0.0% 2.8% 0.5% 1.9% 2.9% 0.6% 0.5% 2.4% 2.8% 3.7% 0.5% 1.6% 2.0% 0.9% 0.5% 1.8% 1.7% 0.5% 5.0% 1.4% ??? ??? 4.7% 0.6% 1.0% 2.0% 4.2% 2.6% 3.9% 5.2% 1.0% 2.4% 2.4% 2.1% 1.9% 1.3% 6.8% 2.0% 0.1% 1.6% 0.4% 0.4% 1.0% 1.1% 3.3% 1.3% 1.2% 3.5% TRAFFIC LIGHT POLE BACK OF CURB BUS ROAD TRANSFORMER TEMPORARY INLET PROTECTION TO BE REMOVED ON REMOVAL OF EXISTING INLET 100' BNSF RAIL-ROAD R.O.W. CONC. DRAINAGE CHANNEL Feet 0 30 60 FORT COLLINS JEEP EROSION CONTROL PLAN TWD 11/20/2017 1" = 30' JLC 16-018 C-6 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE SF LIMITS OF CONSTRUCTION SF CWA CF IP PS SSA VTC LOC CONCRETE WASHOUT AREA CONSTRUCTION FENCE INLET PROTECTION PERMANENT SEEDING SILT FENCE STABILIZED STAGING AREA VEHICLE TRACKING CONTROL BMP LEGEND RS ROCK SOCK BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Know what'sbelow. Call before you dig. R CONSTRUCTION SEQUENCE CHART PROPERTY LINE EXISTING LOT/TRACT LINE LEGEND: S W EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER MAIN EXISTING STORM MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING RIGHT-OF-WAY E G EXISTING GAS MAIN X EXISTING FENCE 5530 PROPOSED CONTOUR 5530 EXISTING CONTOUR PROPOSED AREA OUTLET PROPOSED STORM SEWER CTV EXISTING CATV LINE EXISTING UTILITY RISER EXISTING STREET SIGN 5537.30 FL 2% PROPOSED SLOPE PROPOSED FLOWLINE ELEVATION EXISTING VEGETATION EXISTING BURIED ELECTRIC LINE EXISTING SANITARY SEWER MH COM EXISTING COMMUNICATION LINE HIGH POINT LOW POINT HP LP FG FINISH GRADE Line Over Text Line Over Text 15-94 12/27/17 N 1434215.35 E 3116603.75 N 1434215.26 E 3116608.75 N 1434133.98 E 3116607.20 N 1434133.98 E 3116612.20 N 1433909.92 E 3116607.92 N 1433912.65 E 3116980.38 N 1433925.66 E 3116993.62 N 1434389.41 E 3117002.13 3.0% 0.0% 2.8% 0.5% 1.9% 2.9% 0.6% 0.5% 2.4% 2.8% 3.7% 0.5% 1.6% 0.8% 0.5% 1.8% 1.7% 0.5% 5.0% 1.4% ??? ??? 4.7% 2.0% 4.2% 2.7% 3.9% 5.2% 1.0% 2.4% 2.4% 2.1% 1.9% 1.3% 6.7% 2.0% 0.1% 1.6% 0.4% 0.4% 1.0% 1.1% 3.3% 1.3% 1.2% 3.5% 1.2% 2.5% 100' BNSF RAIL-ROAD R.O.W. 5040 5042 5044 5042 5042 5042 5046 5044 5044 5050 5046 5048 5046 5040 5044 5042 5044 5046 5046 5046 5046 5048 5046 5046 5046 5040 5041 5044.85 FL 5044.38 FL 5044.56 FL 5044.25 FL 5043.22 FL 5043.68 FL 5043.55 FL 5043.16 FL 5043.08 LP 5043.36 FL 5043.41 FL 5043.52 FL 5044.71 FL 5045.49 FL 5045.16 FL 5043.84 FL 5043.71 FL 5044.24 FL 5044.12 FL 5044.31 FL 5044.18 FL 5044.43 FL 5044.25 FL 5044.43 FL 5044.88 FL 5044.71 FL 5045.00 FL 5045.16 FL 5045.35 FL 5044.76 FL 5044.92 FL 5045.06 FL 5045.68 FL 5045.47 FL 5045.70 FL 5044.63 FL 5044.44 FL 5044.66 FL 5043.97 FL 5043.86 FL 5044.17 FL 5044.25 FL 5044.31 FL 5044.93 FL 5044.61 FL 5045.14 FL 5044.66 FL 5044.74 FL 5045.19 HP 5045.39 FL 5045.90 FL 5044.92 FL 5045.47 FL 5045.25 FL 5045.19 FL 5045.40 FL 5044.86 FL 5045.17 FL 5045.07 FL 5045.51 FL 5045.97 FL 5045.91 FL 5045.91 FL 5045.90 FL 5045.95 FL 5045.76 FL 5045.89 FL 5045.54 FL 5045.68 FL 5045.68 FL 5045.55 FL 5045.86 FL 5045.75 FL 5046.02 FL 5045.95 FL 5046.03 FL 5044.15 FL 5044.03 FL 5044.52 FL 5044.57 FL 5042.34 FL 5042.77 FL 5042.56 FL 5045.77 FL 5045.51 FL 5045.13 FL 5045.47 FL 5045.61 FL 5045.48 FL 5045.56 FL 5045.05 FL 5045.28 FL 5045.26 FL 5045.02 FL 5044.34 FL 5044.77 FL 5045.00 FL 5044.72 FL 5044.22 FL 5043.88 FL 5044.09 FL 5045.13 HP 5043.22 FL 5043.73 FL 5046.11 FG 5046.05 FG 5045.79 FG 5045.72 FG 5046.69 FG 5046.66 FG 5046.38 FG 5046.35 FG 5047.17 FG 5045.40 FL 5044.72 FL ??? FG 5046.65 FG 5039.95 FG 5046.08 FG 5046.27 FG ??? FG ??? FG ??? FG ??? FG 5046.50 FG 5046.01 FG 5041.66 FL 5041.46 FL 5040.90 FL 5045.60 FL 5045.04 FL 5044.99 FL 5045.90 FL 5044.68 FL 5043.75 FL 5044.27 FL 5042.01 FL 5042.52 FL 5043.85 FL 5044.22 FL 5044.25 FL 5043.73 FL 5043.85 FL 5043.88 FL 5044.05 FL 5042.46 FL 5042.33 FL 5042.06 FL 5043.59 FL 5043.74 FL 5043.78 FG 5043.95 FL 5045.90 FL 5042.23 FL 5044.54 FL 5042.96 FL 5042.67 FL 5042.35 FL 5042.32 FL 5042.41 FL 5044.06 FL 5044.48 FL 5044.54 FL 5042.24 FL 5045.90 FL 5045.90 FL 5042.17 LP 5042.90 FL 5045.83 FL 5044.59 FL 5044.59 FL 5044.43 FL 5044.45 FL 5044.56 FL 5042.82 FL 5042.76 HP 5044.15 FL 5043.82 FL CONC. DRAINAGE CHANNEL 5045 5046 5044 5040 5041 5042 5040 5042 5043 5040 5044 5043 5045 5044 5044 G G H H TOW=5039.77 BOW=5039.65 TOW=5043.41 BOW=5041.11 TOW=5043.40 BOW=5042.36 TOW=5043.99 BOW=5043.91 5044.34 FL LANDSCAPE WALL LANDSCAPE WALL 5044.11 FL 5044.15 FL 5045.90 FL 5045.63 FL 5045.73 FL 5045.84 FL 5045.90 FL 5045.74 FL 5044.41 FL 5045.23 FL 5.0% 5042.36 FL 2.0% 1.5% 2.0% 0.5% 1.2% Feet 0 30 60 FORT COLLINS JEEP GRADING PLAN TWD 11/20/2017 1" = 30' JLC 16-018 C-5 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 PROPERTY LINE EXISTING LOT/TRACT LINE LEGEND: S W EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER MAIN EXISTING STORM MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING RIGHT-OF-WAY E G EXISTING GAS MAIN X EXISTING FENCE 5530 PROPOSED CONTOUR 5530 EXISTING CONTOUR PROPOSED AREA OUTLET S PROPOSED SANITARY SEWER PROPOSED SIGN > > PROPOSED C.L. SWALE PROPOSED STORM SEWER W PROPOSED WATER MAIN PROPOSED FIRE HYDRANT CTV EXISTING CATV LINE EXISTING UTILITY RISER EXISTING STREET SIGN 5537.30 FL 2% PROPOSED SLOPE PROPOSED FLOWLINE ELEVATION PROPOSED STREET LIGHT EXISTING VEGETATION PROPOSED PHASING LINE EXISTING BURIED ELECTRIC LINE EXISTING SANITARY SEWER MH EXISTING ASPHALT PAVEMENT PROPOSED ROADWAY STRIPING PROPOSED ASPHALT PAVEMENT PROPOSED CONCRETE PAVEMENT PROPOSED DRAINAGE FLOW ARROW COM EXISTING COMMUNICATION LINE PROPOSED CLEANOUT HIGH POINT LOW POINT HP LP FG FINISH GRADE REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Know what'sbelow. Call before you dig. R Line Over Text 12/27/17 15-94 SS SS S S S S S S W W W W W W W W W W S S S S S S S S S W W W W W W W W W W W W W S S S S S EXIST. METAL SHED TO REMAIN EXIST. METAL SHED TO REMAIN EXIST. BUS STOP SHELTER , PAD, & 57.2 LF SIDEWALK TO EXIST. CURB & GUTTER BE REMOVED TO BE REMOVED EXIST. CURB & GUTTER TO BE REMOVED ±178.7' EXIST. ASPHALT TO BE REMOVED EXIST. CURB & GUTTER TO BE REMOVED EXIST. CURB, GUTTER, & ADA RAMPS TO BE REMOVED EXIST. SHRUBS TO BE REMOVED EXIST. BUSHES & TREES TO BE REMOVED EXIST. INLET TO BE REMOVED “/)2)(;,67&85% GUTTER & SIDEWALK TO BE REMOVED EXIST. CURB & GUTTER TO BE REMOVED EXIST. HYDRANT TO BE RELOCATED EXIST. SAN SEWER SERVICE LINE TO BE ABANDONED IN PLACE EXIST. WATER METER TO BE RECYCLED EXIST. CONC. TO BE REMOVED EXIST. ASPHALT TO BE REMOVED EXIST. ASPHALT TO BE REMOVED EXIST. CURB & GUTTER TO BE REMOVED EXIST. ELEC. TRANSFORMER TO REMAIN EXIST. ROADWAY STRIPING TO BE ERADICATED EXIST. CONC. TO BE REMOVED EXIST. "STOP HERE ON RED" SIGN TO BE RELOCATED EXIST. STREET LIGHT WITH "40 MPH" SIGN TO BE RELOCATED EXIST. PEDESTRIAN CROSSING AHEAD SIGN TO REMAIN EXIST. STREET LIGHT WITH "RIAL ROAD CROSSING" SIGN TO REMAIN EXIST. BUS STOP SIGN TO BE RELOCATED EXIST. TREES & SHRUBS TO REMAIN EXIST. DRAINAGE PAN & SIDEWALK CHASE TO REMAIN EXIST. TREE TO REMAIN EXIST. AREA LIGHT EXIST. TREES TO BE REMOVED TO REMAIN EXIST. AREA LIGHTS TO BE REMOVED 57.2' EXIST. BIKE LANE STRIPE TO REMAIN EXIST. STOP BAR TO REMAIN PROPERTY LINE R.O.W. R.O.W. PROPERTY LINE EXIST. CHAIN-LINK FENCE TO REMAIN EXIST. WOOD FENCE TO REMAIN EXIST. CHAIN-LINK FENCE TO BE REMOVED EX. CONC. PAN TO BE REMOVED EXIST. CONC. PAN AND ADA RAMPS TO BE REMOVED ± 91 LF EXIST. CONC. SIDEWALK TO BE REMOVED EXIST. GRAVEL DRIVEWAY / PARKING 100' BNSF RAIL-ROAD R.O.W. Feet 0 30 60 FORT COLLINS JEEP DEMOLITION PLAN TWD 11/20/2017 1" = 30' JLC 16-018 C-4 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' Know what'sbelow. Call before you dig. R STREET CUT NOTE: LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. PROPERTY LINE EXISTING LOT/TRACT LINE LEGEND: S W EXISTING SANITARY SEWER EXISTING STORM SEWER EXISTING WATER MAIN EXISTING STORM MANHOLE EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING RIGHT-OF-WAY E G EXISTING GAS MAIN X EXISTING FENCE 5530 EXISTING CONTOUR CTV EXISTING CATV LINE EXISTING UTILITY RISER EXISTING STREET SIGN EXISTING BURIED ELECTRIC LINE EXISTING SANITARY SEWER MH EXISTING ASPHALT PAVEMENT COM EXISTING COMMUNICATION LINE 12/27/17 Line Over Text 15-94 CURB & GUTTER 12' 60' REVISIONS DESIGN: SCALE: DRAWN: PROJECT NO: DATE: SHEET PARAGON ENGINEERING CONSULTANTS, INC. LITTLETON, CO 80120 303-794-8604 7852 SOUTH ELATI STREET, SUITE 106 Know what'sbelow. Call before you dig. R INFORMATION SHOWN IS SUBJECT TO CHANGE. NOT FOR CONSTRUCTION CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE VICINITY MAP NOT TO SCALE OWNER/DEVELOPER: COMMERCIAL BUILDING SERVICES 7561 S. GRANT STREET, SUITE A-4 LITTLETON, COLORADO 80122 PHONE: (303) 730-3001 CONTACT: STEVE MOORE ENGINEER / PLAN PREPARER: PARAGON ENGINEERING CONSULTANTS, INC. 7852 S. ELATI STREET, SUITE 106 LITTLETON, COLORADO 80120 PHONE: (303) 794-8604 FAX: (303) 795-3072 CONTACT: TROY DENNING, P.E. CONTACTS: CIVIL ENGINEER'S STATEMENT I, TROY W. DENNING, BEING A REGISTERED PROFESSIONAL ENGINEER IN THE STATE OF COLORADO, HEREBY ATTEST THAT ALL GRADING, UTILITY AND DRAINAGE IMPROVEMENTS IDENTIFIED ON THESE UTILITY PLANS HAVE BEEN DESIGNATED AND ENGINEERED IN CONFORMANCE WITH ALL CITY OF FORT COLLINS PUBLIC WORKS CONSTRUCTION STANDARDS. . . TROY W. DENNING P.E. 34200 DATE PARAGON ENGINEERING CONSULTANTS, INC. SITE LEGAL DESCRIPTION: A PARCEL OF LAND LOCATED IN THE SOUTHEAST ONE-QUARTER OF SECTION 35, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE SOUTHEAST CORNER OF SAID SOUTHEAST ONE-QUARTER AND CONSIDERING THE SOUTH LINE OF SAID SOUTHEAST ONE-QUARTER TO BEAR N89°53'00”W; THENCE N89°53'00”W, ALONG SAID SOUTH LINE, A DISTANCE OF 967.13 FEET; THENCE N1°05'37”E A DISTANCE OF 50.00 FEET TO THE POINT OF BEGINNING ON THE NORTHERLY RIGHT-OF-WAY LINE OF WEST HARMONY ROAD; THENCE ALONG THE EASTERLY LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20120033213 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER, THE FOLLOWING SEVEN (7) COURSES: 1. N1°05'37”E A DISTANCE OF 224.10 FEET; 2. N89°58'15”W A DISTANCE OF 5.00 FEET; 3. N1°05'37”E A DISTANCE OF 81.29 FEET; 4. N88°54'23”W A DISTANCE OF 5.00 FEET TO A POINT OF NON-TANGENT CURVE; 5. NORTHWESTERLY, ALONG THE ARC OF SAID CURVE TO THE LEFT, HAVING A CENTRAL ANGLE OF 28°33'29”, A RADIUS OF 150.50 FEET, AN ARC LENGTH OF 75.01 FEET AND A CHORD BEARING AND DISTANCE OF N12°44'40”W, 74.24 FEET TO A POINT OF REVERSE CURVE; 6. NORTHWESTERLY, ALONG THE ARC OF SAID CURVE TO THE RIGHT, HAVING A CENTRAL ANGLE OF 20°00'08”, A RADIUS OF 99.50 FEET, AN ARC LENGTH OF 34.74 FEET AND A CHORD BEARING AND DISTANCE OF N17°01'11”W, 34.56 FEET; 7. N1°05'37”E A DISTANCE OF 70.00 FEET TO THE SOUTH LINE OF LOT 1, PEDERSON AUTO PLAZA SUBDIVISION; THENCE S89°48'40”E, ALONG SAID SOUTH LINE, A DISTANCE OF 435.54 FEET TO THE WESTERLY RIGHT-OF-WAY LINE OF SOUTH MASON STREET; THENCE S1°03'05”W, ALONG SAID WESTERLY LINE, A DISTANCE OF 462.10 FEET TO THE NORTHWESTERLY LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20100010805 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER; THENCE S43°16'52”W, ALONG SAID NORTHWESTERLY LINE, A DISTANCE OF 20.21 FEET TO THE NORTH LINE OF THAT PARCEL OF LAND DESCRIBED AT RECEPTION NO. 20100015829 OF THE RECORDS OF SAID LARIMER COUNTY CLERK AND RECORDER AND SAID NORTHERLY RIGHT-OF-WAY LINE OF WEST HARMONY ROAD; THENCE ALONG SAID LINE THE FOLLOWING THREE (3) COURSES: 1. N89°53'01”W A DISTANCE OF 280.33 FEET; 2. S73°53'58”W A DISTANCE OF 12.50 FEET; 3. N89°53'00”W A DISTANCE OF 91.54 FEET TO THE POINT OF BEGINNING. CONTAINING 195,092 SQUARE FEET OR 4.479 ACRES OF LAND, MORE OR LESS. BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15.94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' I HEREBY AFFIRM THAT THESE FINAL CONSTRUCTION PLANS WERE PREPARED UNDER MY DIRECT SUPERVISION, IN ACCORDANCE WITH ALL APPLICABLE CITY OF FORT COLLINS AND STATE OF COLORADO STANDARDS AND STATUTES, RESPECTIVELY; AND THAT I AM FULLY RESPONSIBLE FOR THE ACCURACY OF ALL DESIGNS, REVISIONS, AND RECORD CONDITIONS THAT I HAVE NOTED ON THESE PLANS. THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BE THE REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE REQUIRED DURING THE CONSTRUCTION PHASE. EXISTING UTILITIES SHOWN ON THESE IMPROVEMENT PLANS ARE APPROXIMATE ONLY. THEY HAVE BEEN LOCATED FROM FIELD SURVEYS AND UTILITY RECORDS. THE CONTRACTOR SHALL CONTACT ALL RESPECTIVE UTILITY COMPANIES TO HAVE ALL UTILITIES FIELD LOCATED PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONS TO PROTECT ALL EXISTING UTILITIES ENCOUNTERED, AND SHALL BE RESPONSIBLE FOR THE IMMEDIATE REPAIR OF ALL UTILITIES DAMAGED DURING CONSTRUCTION WHETHER SHOWN ON THESE PLANS OR NOT. IT SHALL BE THE CONTRACTOR'S FULL RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL EXISTING STRUCTURES AND UTILITIES SHOWN ON THESE IMPROVEMENT PLANS, TO ASCERTAIN WHETHER ANY STRUCTURES AND UTILITIES MAY EXIST, AND TO REPAIR OR REPLACE ANY STRUCTURES AND UTILITIES THAT MIGHT BE DAMAGED. IF ANY UNKNOWN SUBSURFACE STRUCTURES OR UTILITIES ARE ENCOUNTERED DURING CONSTRUCTION, IT SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CIVIL ENGINEER WHOSE NAME APPEARS ON THESE PLANS. FORT COLLINS JEEP COVER SHEET TWD 03/15/2017 N/A JLC 16-018 C-1 A SUBMITTED TO FTC 03/15/2017 B SUBMITTED TO FTC 07/19/2017 C SUBMITTED TO FTC 09/08/2017 D SUBMITTED TO FTC 11/16/17 EXISTING UTILITIES DISCLAIMER : BASIS OF BEARINGS: THE BASIS OF BEARINGS FOR THIS DESCRIPTION IS THE SOUTH LINE OF THE SOUTHEAST ONE-QUARTER OF SECTION 35, T.7N, R.69W, 6TH P.M., CONSIDERED TO HAVE A BEARING OF N89°53'00”W BETWEEN THE SOUTHEAST SECTION CORNER (A 2-1/2” ALUMINUM CAP FOUND IN RANGE BOX, PLS 17497) AND THE SOUTH ONE-QUARTER CORNER (A 3-1/4” ALUMINUM CAP FOUND IN RANGE BOX, PLS 5028). SHEET INDEX Sheet Number Sheet Title C-1 COVER SHEET C-2 CONSTRUCTION NOTES C-3 CONSTRUCTION NOTES C-4 DEMOLITION PLAN C-5 GRADING PLAN C-6 EROSION CONTROL PLAN C-7 OVERALL UTILITY PLAN C-8 MASON STREET WIDENING PLAN C-9.1 MASON STREET CROSS SECTIONS C-9.2 MASON STREET CROSS SECTIONS C-10 BUS STOP PLAN C-11 ROADWAY SIGNAGE & STRIPING PLAN C-12 FIRE LANE SIGNAGE & STRIPING PLAN C-13 DETAILS C-14 DETAILS C-15 DETAILS C-16 DETAILS C-17 DETAILS C-18 DETAILS C-19 DRAINAGE PLAN FORT COLLINS JEEP UTILITY PLANS FOR LOCATED IN THE SOUTHEAST ONE-QUARTER OF SECTION 35, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO OCTOBER, 2017 15-94 12/27/17