HomeMy WebLinkAboutRENNAT SUBDIVISION - PDP190011 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSS. TIMBERLINE DRIVE RD.
KECHTER RD.
ZEPHYR RD.
ALLEY (PRIVATE)
12' TRAVEL LANE
24' -
31" DRIVE-OVER
CURB & GUTTER
12' TRAVEL LANE
11' TRAVEL LANE
9' UTIL. 76' ROW
ESMT.
6' 54' -
PKWY
6'
PKWY
9' UTIL.
ESMT.
MINOR COLLECTOR
5' WALK
5' WALK
11' TRAVEL LANE
5' BIKE LANE
3' BUFFER
8' PARKING
5' BIKE LANE
3' BUFFER
8' PARKING
9' UTIL. 53' ROW
ESMT.
9' UTIL.
ESMT.
RESIDENTIAL LOCAL
7' PARKING
30' -
16' TRAVEL
4.5' WALK
4.5' WALK
4.67'
PKWY
TBC-WALK
4.67'
PKWY
TBC-WALK
7' PARKING
1' x 1'
CONCRETE EDGE
8' UTIL.
ESMT.
8' UTIL.
ESMT.
ALLEY (PRIVATE) - INVERTED CROWN
12' TRAVEL LANE
24' -
12' TRAVEL LANE
8' UTIL.
ESMT.
8' UTIL.
ESMT.
7' MIN FENCE SETBACK
GENERAL NOTES
1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the
Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and
the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the
City of Fort Collins.
2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins
Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to
commencement of any work shown in these plans.
4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as
beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort
Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by
law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all
liabilities, claims, and demands which may arise from any errors and omissions contained in these plans.
5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and
specifications current at the date of approval of the plans by the City of Fort Collins Engineer.
6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the
responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing
new construction. The Developer shall be responsible for unknown underground utilities.
7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning
excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to
be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading.
It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these
plans.
8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for
any utility crossings required.
9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the
engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is
accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance,
all parties affected by any disruption of any utility service as well as the utility companies.
11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility
provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility
provider, a pre-construction meeting may be required prior to commencement of any work.
12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and
sanitary sewer should be constructed prior to installation of the water lines and dry utilities.
13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the
Water Utility.
14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is
discharged into a storm sewer, channel, irrigation ditch or any waters of the United States.
15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department
of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of
onsite drainage facilities shall be the responsibility of the property owner(s).
17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be
submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at
least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be
submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed
prior to certification per the Development Agreement.
18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater
seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as
a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development.
19. All recommendations of the Preliminary Drainage and Erosion Control Report for Rennat Subdivision dated July 31, 2019 by Northern
Engineering Services, Inc., shall be followed and implemented.
20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall
be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and
debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.)
or as approved by the the City of Fort Collins street inspector.
22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction
12" W
12" W
X
SS
VAULT
ELEC
X
X
X
X
X
IRR
WM WM WM WM
WM
WM
WM WM
WM
WM
WM
WM WM
WM WM
WM
WM
WM
WM WM
WM WM WM
WM
WM
WM WM
WM WM WM WM
WM
WM
WM
WM
WM
WM WM
WM
WM
WM
WM
WM
UD
UD
UD
LID
W
S
O
E
T
VAULT
TELE
T
LID
VAULT
TELE
W
S
O
H
12" W
12" W
X
SS
VAULT
ELEC
X
X
X
X
X
IRR
WM WM WM WM
WM
WM
WM WM
WM
WM
WM
WM WM
WM WM
WM
WM
WM
WM WM
WM WM WM
WM
WM
WM WM
WM WM WM WM
WM
WM
WM
WM
WM
WM WM
WM
WM
WM
WM
WM
UD
UD
UD
VAULT
TELE
T
VAULT
TELE
W
S
O
H
Y
D
W
TELE
VAULT
ELEC
VAULT
X
X
X
X
X
X
X
X
X
X
X
PROPERTY BOUNDARY (TYP.)
MAIL CREEK DITCH
UNION PACIFIC RAILROAD
DITCH LATERAL
NATURAL
HABITAT
BUFFER
ZONE
FUTURE
PEDESTRIAN
BRIDGE
200.00' PUBLIC
ACCESS TRAIL
EASEMENT
5' TRAIL
5' TRAIL
VAULT
TELE
ELEC
E
ELEC
BRKR
X
X
X
X
X X
X
X
X
X
X X X
X
X
X
X
X
X
X
X X
X
X
X
X X
X
X X
X
X
X
X
X
X
X X X X X X X X X X
X
X X X X X X X X
X
X X
X
X X
X
X X X
X X
X
X
X
X
X
X X X
X
X
FO
FO
FO
E
E
E
STREET B
STREET C
STREET D
STREET B2
STREET A
STREET F
PROPOSED FIRE
HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
STORM DRAIN
9' UTILITY EASEMENT
9' UTILITY EASEMENT
6' UTILITY
EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT 9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
6' UTILITY
EASEMENT
T
VAULT
TELE
W
S
O
H
Y
D
W
VAULT
ELEC
VAULT
ELEC
H
Y
D
S S
S
X
X X
X X X
X
X
X
X X X
X
X
X
X X
SS SS
SS
SS SS
SS
SS SS
SS
SS SS SS SS
SS
LID
VAULT
F.O.
W W W
FO
FO
FO
FO
FO
FO
FO
FO
FO FO FO
FO
FO FO
FO
FO
FO
FO
FO
FO
FO
VAULT
TELE
T
VAULT
TELE
W
S
O
H
Y
D
W
TELE
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
H
Y
D
S S
S
ELEC
E
ELEC
BRKR
X
X
X X X X X X X
X
X X
X
X
X
X
X
X X
X
X X X X
X
X
X
X
X
X
X
X X
X
X
X
X X X X X
X
X
X
SS
SS
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
6' UTILITY
EASEMENT
UNION PACIFIC RAILROAD
DITCH LATERAL
50' NATURAL
HABITAT
BUFFER
PLANNED
HANSEN FARM
BLOCK 11
LOT 2 LOT 3
LOT 1 LOT 4
PROPERTY
BOUNDARY (TYP.)
PLANNED
PEDESTRIAN
CROSSING
200.00' PUBLIC
ACCESS TRAIL
EASEMENT
5' TRAIL
5' TRAIL
5' TRAIL
5' TRAIL
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
ELEC
E
ELEC
BRKR
X
X
X
X
X
X X
X
X
X X X
X X
X X
X
X
X
X X
X
X
X X
X
X
X
X
X X
X X
X
X X
X
X
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E
E
E
E
E
E
E
E
E
E
STREET A
FALLEN BRANCH DR
6' UTILITY
EASEMENT
30' FL-FL
53' ROW
59' ROW
36' FL-FL
X
X X
X X X X X X X X X X X X X X
X
X X
X X X X X X
X X X
X X X
X
X
X
X X
X
X
STREET B
STREET C
STREET F
6' UTILITY EASEMENT
6' UTILITY
EASEMENT
53' ROW 30' FL-FL
20'
9' UTILITY EASEMENT
9' UTILITY EASEMENT 9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
BLOCK 13
BLOCK 7
BLOCK 7
BLOCK 9
BLOCK 8
BLOCK 9
LOT 7
TRACT F
LOT 15
LOT 11
LOT 9
LOT 10
LOT 12
TRACT P
LOT 13
LOT 14
LOT 17
LOT 16
LOT 11
LOT 9
LOT 10
LOT 8
LOT 7
LOT 7
LOT 6
LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1
LOT 13
LOT 14
LOT 12
LOT 2
LOT 10
VAULT
TELE
VAULT
F.O.
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E
E
E E
E E E
E
E
E
E
E
E
E
E
T
T
T
T
T
T
T
STREET A
STREET C
NATURAL
HABITAT
BUFFER
ZONE
53' ROW
53' ROW
30' FL-FL
30' FL-FL
30' EASEMENT
REC. NO. 20140004033
15' EASEMENT
REC. NO. 20110070565
9' UTILITY EASEMENT
H
Y
D
W
TELE
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
S S
S
X X
X X X X X
X
X
X
X X
X
SS
SS
SS
SS
SS
SS SS
SS
SS
SS SS
SS
SS SS
SS
V
AULT
F.O.
FO
FO
FO FO FO
FO
FO
FO
FO
FO
FO
FO
FO
E
T T
T
T
T
T
T
T T
T
T
T
T
T
VAULT
TELE
W
S
O
H
Y
D
X
X X
X
X
X X
X
X X X
X
X
X X X X
SS SS SS
LID
W W W
FO
FO
FO FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
T
T T
T
T
T
T T T
T
T
G
G
G
G
W
W
W
W
T
ZEPHYR RD
60' EASEMENT
REC. NO. 20100010642
15' EASEMENT
REC. NO. 20110070565
9' UTILITY EASEMENT
9' UTILITY EASEMENT
E
E
4955
4960
4965
4970
4975
4980
4955
4960
4965
4970
4975
4980
9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+75
STREET A CL
EXISTING GROUND
PROPOSED GRADE
4965.19
4966.05
4966.54
4967.04
4968.03
4970.03
4971.64
4965.91
4965.95
4966.00
4966.17
4966.29
4966.42
4966.67
4966.79
4966.92
4967.17
4967.33
4967.62
4968.53
4969.03
4969.53
4970.53
4971.03
4971.48
4971.49
4971.02
2.00%
-3.00%
2.85%
0.19%
0.50%
PVI STA = 10+00.00
PVI ELEV = 4965.19
PVI STA = 10+24.97
PVI ELEV = 4965.91
PVI STA = 11+03.74
PVI ELEV = 4966.06
100.0' VC
HP ELEV = 4971.64
HP STA = 16+00.42
PVI STA = 16+10.42
PVI ELEV = 4972.24
BVCS: 15+60.42
STA. = 20+00.00
(STREET A)
STA. = 10+01.01
(STREET C)
53'
ROW
30'
FL-FL
STA. = 22+41.77
(STREET A)
STA. = 10+00.00
(STREET D)
STREET A
LOT 4
LOT 15
LOT 14
LOT 1
LOT 2 LOT 10
LOT 11
LOT 1 LOT 2 LOT 3 LOT 4 LOT 5 LOT 6 LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 LOT 13 LOT 14 LOT 15
LOT 7 LOT 6 LOT 5 LOT 3 LOT 2 LOT 1
LOT 1
LOT 2
TRACT S
DUA&EAE
TRACT D
DUA&EAE
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
STREET C
SEE SHEET R7
STREET D
SEE SHEET R8
PROPOSED DRIVE OVER
CURB AND GUTTER BLOCK 12
BLOCK 12 BLOCK 12
BLOCK 10
BLOCK 14
BLOCK 15
BLOCK 16
BLOCK 13
PROPOSED 5' CROSS PAN
TRACT A
DRAINAGE
EASEMENT
"STOP" SIGN w/
STREET NAMES
"STOP" SIGN w/
STREET NAMES
4955
4960
4965
4970
4975
∆
30'
FL-FL
53'
ROW
STA. = 24+82.77
(STREET A)
STA. = 25+54.57
(STREET B)
STA. = 28+61.66
(STREET A)
STA. = 20+55.65
(ZEPHYR RD)
STREET A
LOT 2
LOT 11
LOT 1
LOT 2
LOT 4 LOT 3 LOT 1
LOT 19
LOT 18
LOT 17
LOT 16
LOT 15
LOT 12
LOT 10
LOT 11
LOT 9
LOT 8
LOT 7
LOT 23
LOT 6
LOT 5
TRACT C
FUTURE PARK
TRACT T
DUE
TRACT V
TRACT D
DUA&EAE
TRACT R
DUA&EAE
9' UTILITY EASEMENT
4.5' SIDEWALK
EP: 28+61.66
PC: 25+04.09
PT: 26+85.21
9' UTILITY EASEMENT
4.5' SIDEWALK
PROPOSED DRIVE OVER
CURB AND GUTTER
STREET B2
SEE SHEET
R5
ZEPHYR RD
SEE SHEET
R11
BLOCK 5
BLOCK 4
ZEPHYR RD
STREET B
∆
STA. = 12+58.49
(STREET B)
STA. = 11+33.93
(STREET F)
STA. = 15+67.52
(STREET B)
STA. = 18+72.78
(STREET C)
STREET F
SEE SHEET R9
STREET C
SEE SHEET R6
LOT 10
LOT 15
LOT 17
LOT 16
LOT 3
LOT 1
LOT 2
LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 6 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1
LOT 14
LOT 12
LOT 11 LOT 9 LOT 8
LOT 2
LOT 10
LOT 9 LOT 2
LOT 1
LOT 3
LOT 1
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
53'
ROW
30'
FL-FL
PROPOSED DRIVE OVER
CURB AND GUTTER
BP: 10+00.00
PT: 11+03.74
TRACT S
DUA&EAE
BLOCK 7
BLOCK 6
BLOCK 9
BLOCK 8
BLOCK 13 BLOCK 14
CURB CUT &
CONCRETE RUNDOWN
"STOP" SIGN w/
STREET NAMES
"STOP" SIGN w/
STREET NAMES
STA. = 18+08.52
(STREET B)
STA. = 16+96.43
(STREET D)
LOT 5
LOT 3
LOT 1
LOT 2 LOT 12
LOT 11
LOT 13
LOT 3
LOT 2
LOT 9 LOT 8
LOT 4
LOT 7 LOT 6
LOT 1
53'
ROW
30'
FL-FL
PROPOSED DRIVE OVER
CURB AND GUTTER
STREET D
SEE SHEET R8
4.5' SIDEWALK
9' UTILITY EASEMENT
PC: 20+14.52
TRACT D
DUA&EAE
BLOCK 6
BLOCK 14
BLOCK 15 BLOCK 16
STREET B
∆
∆
LOT 6
LOT 8
LOT 9
LOT 1
LOT 2
LOT 6
LOT 3
LOT 7 LOT 4
LOT 5
LOT 2 LOT 3 LOT 4 LOT 5 LOT 6
LOT 10
LOT 7
LOT 11
LOT 2
LOT 1
LOT 1
PROPOSED DRIVE OVER
CURB AND GUTTER
30'
FL-FL
53'
ROW
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
STREET C
STA. = 10+00.00
(STREET C)
STA. = 20+00.77
(STREET A)
STA. = 18+72.78
(STREET C)
STA. = 15+67.52
(STREET B)
∆
LOT 10
LOT 1
LOT 1
LOT 2
LOT 3
LOT 4
LOT 5
LOT 6 LOT 7
LOT 15
LOT 11
LOT 9
LOT 10
LOT 12
LOT 74
LOT 13
LOT 14
LOT 17
LOT 6 LOT 16
LOT 7
LOT 12 LOT 8
LOT 11 LOT 10 LOT 89
LOT 14 LOT 13
LOT 8
LOT 9
LOT 2
LOT 3
LOT 1
LOT 4
LOT 7 LOT 6
LOT 5
STREET A
SEE SHEET
R2
STREET A
SEE SHEET
R2
TRACT P
TRACT G
TRACT S
DUA&EAE
TRACT A
DRAINAGE
EASEMENT
53'
ROW
30'
FL-FL
STREET B
SEE SHEET
R4
X X X X X X
LOT 10
LOT 1
LOT 2
LOT 11
STREET B
SEE SHEET
R4
EP: 27+06.82
PROPERTY BOUNDARY (TYP.)
END OF ROADWAY MARKER
PRAIRIE HILL
DRIVE
4935
4940
4945
4950
4955
4960
4935
4940
4945
4950
4955
4960
19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 27+25
0.50%
-0.50%
0.50%
PVI STA = 26+77.39
PVI ELEV = 4947.00
75.0' VC
HP ELEV = 4948.18
HP STA = 20+15.87
PVI STA = 20+15.87
PVI ELEV = 4948.27
BVCS: 19+78.37
BVCE: 4948.08
EVCS: 20+53.37
EVCE: 4948.08
A.D. = 1.00
K = 75.00
75.0' VC
LP ELEV = 4946.07
LP STA = 24+73.58
PVI STA = 24+73.58
PVI ELEV = 4945.98
BCVS: 24+36.08
BVCE: 4946.17
ECVS: 25+11.08
EVCE: 4946.17
A.D. = 1.00
K = 75.00
0.50%
-0.50%
0.50%
PVI STA = 26+77.39
PVI ELEV = 4947.00
75.0' VC
HP ELEV = 4948.18
STREET D
STA. = 10+00.00
(STREET D)
STA. = 22+41.77
(STREET A)
STA. = 16+96.43
(STREET D)
STA. = 18+08.52
(STREET B)
∆
53'
ROW
30'
FL-FL
STREET B
SEE SHEET
R4
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
LOT 17
LOT 3
LOT 6
LOT 7
LOT 82
LOT 5
LOT 4
LOT 1
LOT 2
LOT 12 LOT 10 LOT 8
LOT 11
LOT 15
LOT 13
LOT 14
LOT 1
LOT 2
LOT 4
LOT 3
LOT 5
LOT 9
LOT 6
LOT 7
LOT 8
LOT 12
LOT 10
LOT 11
LOT 13
LOT 8 LOT 7
LOT 12
LOT 11
LOT 2
LOT 9
LOT 5
TRACT Q
TRACT G
4960
4965
4970
4975
4980
4985
4960
4965
4970
4975
4980
4985
9+50 10+00 11+00 12+00 13+00 13+50
-4.40%
-2.20%
2.00%
2.40%
PVI STA = 10+00.00
PVI ELEV = 4971.64
PVI STA = 10+13.83
PVI ELEV = 4971.33
PVI STA = 10+16.84
PVI ELEV = 4971.26
PVI STA = 10+19.84
PVI ELEV = 4971.33
PVI STA = 10+31.84
PVI ELEV = 4971.57
PVI STA = 13+03.12
PVI ELEV = 4967.67
136.0' VC
HP ELEV = 4973.35
HP STA = 11+29.98
PVI STA = 11+49.98
PVI ELEV = 4974.41
BVCS: 10+81.98
BVCE: 4972.78
EVCS: 12+17.98
EVCE: 4971.42
A.D. = 6.80
K = 20.00
-4.40%
-2.20%
2.00%
2.40%
PVI STA = 10+00.00
PVI ELEV = 4971.64
PVI STA = 10+13.83
PVI ELEV = 4971.33
PVI STA = 10+16.84
PVI ELEV = 4971.26
PVI STA = 10+19.84
PVI ELEV = 4971.33
PVI STA = 10+31.84
PVI ELEV = 4971.57
PVI STA = 13+03.12
PVI ELEV = 4967.67
136.0' VC
HP ELEV = 4973.35
HP STA = 11+29.98
PVI STA = 11+49.98
4950
4955
4960
4965
4970
4975
4950
4955
4960
4965
4970
4975
19+50 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00
PVI STA = 10+19.73
PVI ELEV = 4962.45
PVI STA = 18+69.31
PVI ELEV = 4962.49
-1.50%
3.00%
-3.50%
PVI STA = 10+19.73
PVI ELEV = 4962.45
PVI STA = 18+69.31
PVI ELEV = 4962.49
270.0' VC
LP ELEV = 4961.48
LP STA = 11+29.50
PVI STA = 11+74.50
PVI ELEV = 4960.13
BCVS: 10+39.50
BVCE: 4962.16
ECVS: 13+09.50
EVCE: 4964.18
A.D. = 4.50
K = 60.00
4962.37
4962.01
4961.73
4961.55
4961.48
4961.52
4961.65
4961.89
4962.24
4962.69
4963.24
4963.90
4964.65
4965.40
4966.15
4966.89
4967.54
4968.10
4968.54
4968.89
4969.13
4969.26
4969.29
4969.22
4969.04
4945
4950
4955
4960
4965
4970
4945
4950
4955
4960
4965
4970
29+00 28+00 27+00 26+00 25+00 24+00 23+00 22+00 21+00 20+00 19+50
PVI STA = 24+25.06
PVI ELEV = 4955.48
0.55%
PVI STA = 24+25.06
PVI ELEV = 4955.48
283.5' VC
LP ELEV = 4954.47
LP STA = 22+21.17
PVI STA = 21+17.92
PVI ELEV = 4953.79
BCVS: 19+76.17
BVCE: 4958.75
ECVS: 22+59.67
EVCE: 4954.57
A.D. = 4.05
K = 70.00
4957.96
4955.52
4954.50
4954.79
4955.34
4958.80
4957.22
4956.56
4955.99
4955.13
4954.83
4954.62
4954.47
4954.53
4954.66
4954.93
4955.07
4955.21
4955.48
PROPOSED
GRADE
EXISTING
GROUND
15" RCP
STA.=22+21.17
INV.=4949.20
15" RCP
STA.=21+79.22
INV.=4948.73
PT: 24+16.71
EP: 29+20.67
12" W
12" W
X
SS
VAULT
ELEC
X
X
X
X
X
IRR
WM WM WM WM
WM
WM
WM WM
WM
WM
WM
WM WM
WM WM
WM
WM
WM
WM WM
WM WM WM
WM
WM
WM WM
WM WM WM WM
WM
WM
WM
WM
WM
WM WM
WM
WM
WM
WM
WM
UD
UD
UD
VAULT
TELE
T
VAULT
TELE
W
S
O
H
Y
D
W
TELE
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
H
Y
D
S S
S
ELEC
E
ELEC
BRKR
X
X
X X X X X X X
X
X X
X
X
X
X
X
X X
X
X X X X
X
X
X
X
X
X
X
X X
X
X
X
X X X X X
X
X
X
SS
SS
SS SS
SS SS
LID
VAULT
F.O.
W W W
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E
E
E
E
E
E
E
E
E
T
T
T T
T
T
T T
T
T
T
G
G
G
G
G
G
T
T
T
W
W
W
W
W W
W
X
X
X
X
X
X X
X
X
X
X X X X X
X
X
X
4
1
2
3
6b
8
13
10
OS1
11a
4
11b
1
2
5
6b
7b
8 3
13
12 12
10
9
9
5
7b
11b
OS1
6a
7a
7a
6a
11a
STREET A
STREET B
STREET C
STREET D
STREET B2
STREET A
ZEPHYR RD
FALLEN BRANCH DR
STREET F
DITCH LATERAL
UNION-PACIFIC RAILROAD
EXISTING
DETENTION POND
DETENTION
POND 1
RED WILLOW
DRIVE
STREET B
X
X
X
X
X
X
X
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
DR1
DRAINAGE EXHIBIT
26
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
MATCHLINE-THIS SHEET
MATCHLINE-THIS SHEET
LEGEND:
PROPOSED CONTOUR
PROPOSED STORM SEWER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CURB & GUTTER
PROPERTY BOUNDARY
PROPOSED INLET
DESIGN POINT A
FLOW ARROW
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
PROPOSED SWALE SECTION
1
B2
1.45 ac
1
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
DRAINAGE SUMMARY TABLE
DESIGN
POINT
BASIN
ID
TOTAL
AREA
(acres)
C2 C100
2-yr
Tc
(min)
100-yr
Tc
(min)
Q2
(cfs)
Q100
(cfs)
1 1 4.34 0.54 0.67 14.1 14.1 4.5 19.5
2 2 3.33 0.52 0.65 12.8 12.8 3.5 15.3
3 3 4.32 0.60 0.75 13.9 13.9 5.1 22.1
4 4 23.91 0.37 0.46 11.2 11.2 18.8 81.8
5 5 1.54 0.59 0.74 14.7 14.7 1.7 7.5
6a 6a 0.73 0.60 0.75 11.4 11.4 0.9 4.1
6b 6b 2.26 0.53 0.66 13.5 13.5 2.4 10.3
7a 7a 1.10 0.54 0.68 12.6 12.6 1.2 5.3
7b 7b 3.83 0.54 0.67 14.2 14.2 4.0 17.3
8 8 1.72 0.54 0.67 12.5 12.5 1.9 8.3
9 9 1.57 0.57 0.71 14.9 14.9 1.7 7.3
10 10 0.09 0.63 0.79 6.4 6.4 0.1 0.6
11a 11a 2.23 0.60 0.75 13.3 13.3 2.6 11.6
11b 11b 0.95 0.37 0.46 10.4 10.4 0.8 3.4
12 12 3.05 0.52 0.65 15.5 15.5 2.9 12.8
13 13 2.51 0.59 0.74 13.0 13.0 2.9 12.9
OS1 OS1 0.34 0.71 0.88 13.0 13.0 0.5 2.1
H
Y
D
W
TELE
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
S
S
X
X
SS
SS
SS
SS
SS
E
G
G
G
T
T
T
W
W
W
W
W
W
LOT 1
RED WILLOW DR
ROSEN DRIVE
TRACT E
DGE
PC: 18+69.31
PT: 24+16.71
S
SS SS
T
W
W
LOT 1
LOT 83
LOT 2
LOT 3
LOT 12
LOT 13
LOT 10
LOT 11
LOT 9
LOT 8
LOT 23 LOT 7
LOT 5 LOT 6
LOT 4
LOT 1
LOT 2
LOT 10
TRACT C
FUTURE PARK
TRACT T
DUE
TRACT K
DUA&EAE
TRACT V
ZEPHYR RD
STA. = 20+55.65
(ZEPHYR RD)
STA. = 28+61.66
(STREET A)
5' SIDEWALK
9' UTILITY EASEMENT
5' SIDEWALK
PROPOSED VERTICAL
CURB AND GUTTER
ROSEN DRIVE
STREET A
SEE SHEET
R3
11' TRAVEL LANE
11' TRAVEL LANE
5' BIKE LANE
5' BIKE LANE
8' PARKING
8' PARKING
3
76'
ROW
54'
FL-FL
A
5
5
PROPOSED
STORM DRAIN
9' UTILITY EASEMENT
BLOCK 1
TRACT E
DGE
NORTH
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
LINE
MATCH
STA
24+00
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
LINE
MATCH STA
24+00
LINE
MATCH
STA
19+50
NORTH
CENTERLINE
ZEPHYR RD
SCALE : 1" = 40' (H) 1" = 5' (V)
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
G G
8" SOLID WHITE LINE
(2) 4" SOLID LINES; 4" APART
DOUBLE YELLOW LINE
DOUBLE YELLOW LINE
4" SOLID LINE, 4" DASHED LINE; 4" APART
STRIPING LEGEND:
PAVEMENT STRIPING AND MARKINGS:
6" SOLID WHITE LINE
PREFORMED PLASTIC PAVEMENT MARKING
BICYCLIST AND ARROW
1
3
4
5
A
2
8" DASHED WHITE LINE
PREFORMED PLASTIC PAVEMENT MARKING
24" WIDE STOP BAR
PREFORMED PLASTIC PAVEMENT MARKING
RIGHT TURN ARROW (15.5 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
LEFT TURN ARROW (15.5 S.F. EA.)
PREFORMED PLASTIC PAVEMENT
MARKING "ONLY" (22.5 S.F. EA.)
C
B
D
E
3' STRIPE, 9' GAP
6 6" DOTTED WHITE LINE
7 4" SOLID YELLOW LINE
F 18" x 12' CROSS-WALK ON LANE LINES
3' STRIPE, 9' GAP
8
4" WHITE LINE
10' STRIPE, 30' GAP
R11
PLAN & PROFILE
ZEPHYR RD
25
4968.76
4968.38
4967.89
4967.29
4966.60
4965.79
4964.92
4964.05
4963.17
4962.30
4961.42
4960.55
TIE TO SOUTH
CURB & GUTTER
STA.=14+96.14
EL. = 4968.842
TIE TO NORTH
CURB & GUTTER
STA.=15+50.27
EL. = 4969.263
FUTURE
GRADE
EXISTING
GROUND
PROPOSED
GRADE
390.0' VC
HIGH PT ELEV = 4969.30
HIGH PT STA = 15+70.00
PVI STA = 15+85.00
PVI ELEV = 4972.45
A.D. = 6.50
K = 60.00
BVCS: 13+90
BVCE: 4966.60
EVCS: 17+80
EVCE: 4965.62
/ / / / / / / / / / / / / / / /
BP: 10+00.00
PC: 18+69.31
16" W
16" W
16" W
16" W
CTV CTV
CTV
CTV
FO
T
8" W
T S
T S
E E
E E E
E E
T
LOT 14 LOT 15 LOT 16 LOT 17 LOT 18 LOT 19 LOT 20 LOT 21
LOT 12
LOT 13
LOT 10
LOT 11
TRACT O
DU&PAE
ZEPHYR RD
LOT 22
5' SIDEWALK
9' UTILITY EASEMENT
5' SIDEWALK
9' UTILITY EASEMENT
BLOCK 1
PLANNED
HANSEN FARM
3
TIMBERLINE ROAD
BURLEY TREE DRIVE
11' TRAVEL LANE
11' TRAVEL LANE
5' BIKE LANE
5' BIKE LANE
8' PARKING
8' PARKING
A 5
5
ZEPHYR RD
PROPOSED 30"
VERTICAL CURB &
GUTTER
PROPOSED 30"
VERTICAL CURB &
GUTTER
EXISTING 30"
VERTICAL CURB &
GUTTER
EXISTING
STRIPING
EXISTING 30"
VERTICAL CURB &
GUTTER
76'
ROW
54'
FL-FL
DITCH LATERAL
76'
ROW
54'
FL-FL
15' EASEMENT
REC. NO. 20140004033
TRACT C
FUTURE PARK
R10
PLAN & PROFILE
ZEPHYR RD
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
NORTH
LINE
MATCH
STA
19+50
CENTERLINE
ZEPHYR RD
SCALE : 1" = 40' (H) 1" = 5' (V)
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
MATCH LINE SEE SHEET R11 STA 19+50
G G
8" SOLID WHITE LINE
(2) 4" SOLID LINES; 4" APART
DOUBLE YELLOW LINE
DOUBLE YELLOW LINE
4" SOLID LINE, 4" DASHED LINE; 4" APART
STRIPING LEGEND:
PAVEMENT STRIPING AND MARKINGS:
6" SOLID WHITE LINE
PREFORMED PLASTIC PAVEMENT MARKING
BICYCLIST AND ARROW
1
3
4
5
A
2
8" DASHED WHITE LINE
PREFORMED PLASTIC PAVEMENT MARKING
24" WIDE STOP BAR
PREFORMED PLASTIC PAVEMENT MARKING
RIGHT TURN ARROW (15.5 S.F. EA.)
PREFORMED PLASTIC PAVEMENT MARKING
LEFT TURN ARROW (15.5 S.F. EA.)
PREFORMED PLASTIC PAVEMENT
MARKING "ONLY" (22.5 S.F. EA.)
C
B
D
E
3' STRIPE, 9' GAP
6 6" DOTTED WHITE LINE
7 4" SOLID YELLOW LINE
F 18" x 12' CROSS-WALK ON LANE LINES
3' STRIPE, 9' GAP
8
4" WHITE LINE
10' STRIPE, 30' GAP
PVI ELEV = 4974.41
BVCS: 10+81.98
BVCE: 4972.78
EVCS: 12+17.98
EVCE: 4971.42
A.D. = 6.80
K = 20.00
4971.64
4971.44
4972.01
4972.61
4973.13
4973.35
4973.25
4972.85
4972.13
4971.11
4970.01
4968.91
4967.81
TIE TO EXISTING
ASPHALT
PROPOSED GRADE
EXISTING GROUND
PROPOSED GRADE EXISTING GROUND
24"x36"
STA.=12+15.74
INV.=4967.93
FUTURE GRADE
FO
FO
FO
FO
FO
FO
E
E
E
E
E
E
FALLEN BRANCH DR
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
LOT 1
LOT 8
LOT 6
LOT 7
LOT 9
LOT 14
BP: 10+00.00
STA. = 10+00.00
(STREET E)
STA. = 16+00.42
(STREET A)
STREET A
SEE SHEET R1
STREET A
SEE SHEET R2
PROPOSED DRIVE OVER
CURB AND GUTTER
PLANNED HANSEN FARM
PLANNED HANSEN FARM
PLANNED
24"x36" RCBC
BLOCK 12
BLOCK 11
BLOCK 10
TRACT A
DRAINAGE
EASEMENT
30' EASEMENT
REC. NO. 20140004033
15' EASEMENT
REC. NO. 20110070565
36'
FL-FL
59'
ROW
DITCH LATERAL
"STOP" SIGN w/
STREET NAMES
KNOBBY PINE DRIVE
KNOBBY PINE DRIVE
STREET F
LOT 6
LOT 7
LOT 5
LOT 4
LOT 10
LOT 8 LOT 9
LOT 5
LOT 4
LOT 3
LOT 7
LOT 6
STREET B
SEE SHEET R4
STREET B
SEE SHEET R4
4.5' SIDEWALK
9' UTILITY EASEMENT
PROPOSED DRIVE OVER
CURB AND GUTTER
BLOCK 8
BLOCK 7
BP: 10+00.00
PT: 10+98.93
EP: 11+33.93
STA. = 11+33.93
(STREET F)
STA. = 12+58.49
(STREET B)
R50'
30'
FL-FL
54'
ROW
"STOP" SIGN w/
STREET NAMES
4935
4940
4945
4950
4955
4960
4935
4940
4945
4950
4955
4960
9+75 10+00 11+00 11+50
2.20%
-2.00% -2.00%
-1.60%
PVI STA = 10+00.00
PVI ELEV = 4948.74
PVI STA = 10+25.63
PVI ELEV = 4948.23
PVI STA = 10+98.93
PVI ELEV = 4947.05
PVI STA = 11+14.09
PVI ELEV = 4946.75
PVI STA = 11+17.09
PVI ELEV = 4946.68
PVI STA = 11+20.09
PVI ELEV = 4946.75
PVI STA = 11+33.93
PVI ELEV = 4947.05
2.20%
-2.00% -2.00%
-1.60%
PVI STA = 10+00.00
PVI ELEV = 4948.74
PVI STA = 10+25.63
PVI ELEV = 4948.23
PVI STA = 10+98.93
PVI ELEV = 4947.05
PVI STA = 11+14.09
PVI ELEV = 4946.75
PVI STA = 11+17.09
PVI ELEV = 4946.68
PVI STA = 11+20.09
PVI ELEV = 4946.75
PVI STA = 11+33.93
PVI ELEV = 4947.05
4948.74
4948.24
4947.84
4947.44
4947.03
4946.86
PROPOSED GRADE
EXISTING GROUND
PROPOSED GRADE EXISTING GROUND
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
NORTH
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
CENTERLINE
FALLEN BRANCH DR
SCALE : 1" = 40' (H) 1" = 5' (V)
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
E
R9
PLAN & PROFILE
FALLEN BRANCH DR & STREET F
----
CENTERLINE
STREET F
SCALE : 1" = 40' (H) 1" = 5' (V)
F
TRACT I
TRACT H
TRACT S
DUA&EAE
TRACT D
DUA&EAE
BP: 10+00.00
EP: 16+96.43
PC: 11+17.39
PT: 14+75.24
STREET A
SEE SHEET
R2
STREET A
SEE SHEET
R2
STREET B
SEE SHEET
R5
LOT 13
PROPOSED DRIVE OVER
CURB AND GUTTER
BLOCK 14
BLOCK 14
BLOCK 15
BLOCK 15
"STOP" SIGN w/
STREET NAMES
4945
4950
4955
4960
4965
4970
4945
4950
4955
4960
4965
4970
9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+25
-2.20%
2.20%
-2.00%
-6.00%
-0.50%
-2.00%
PVI STA = 10+00.00
PVI ELEV = 4965.71
PVI STA = 10+13.83
PVI ELEV = 4965.40
PVI STA = 16+96.43
PVI ELEV = 4949.11
PVI STA = 16+76.59
PVI ELEV = 4948.80
PVI STA = 16+79.59
PVI ELEV = 4948.73
PVI STA = 16+82.59
PVI ELEV = 4948.80
80.0' VC
PVI STA = 11+08.83
PVI ELEV = 4963.50
BVCS: 10+68.83
BVCE: 4964.30
EVCS: 11+48.83
EVCE: 4961.10
A.D. = 4.00
K = 20.00
50.0' VC
PVI STA = 16+26.59
PVI ELEV = 4949.80
BVCS: 16+01.59
BVCE: 4949.93
EVCS: 16+51.59
EVCE: 4949.30
A.D. = 1.50
K = 33.33
165.0' VC
PVI STA = 13+10.87
PVI ELEV = 4951.38
BCVS: 12+28.37
BVCE: 4956.33
ECVS: 13+93.37
EVCE: 4950.97
A.D. = 5.50
K = 30.00
PROPOSED GRADE
EXISTING GROUND
4965.71
4965.18
4964.68
4964.17
4963.44
4962.39
4961.03
4959.53
4958.03
4956.53
4955.11
4953.89
4952.89
4952.09
4951.50
4951.12
4950.93
4950.81
4950.68
4950.56
4950.43
4950.31
4950.18
4950.06
4949.93
4949.73
4949.33
4948.83
PROPOSED GRADE EXISTING GROUND
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
NORTH
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
CENTERLINE
STREET D
SCALE : 1" = 40' (H) 1" = 5' (V)
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
D
R8
PLAN & PROFILE
STREET D
22
HP STA = 20+15.87
PVI STA = 20+15.87
PVI ELEV = 4948.27
BVCS: 19+78.37
BVCE: 4948.08
EVCS: 20+53.37
EVCE: 4948.08
A.D. = 1.00
K = 75.00
75.0' VC
LP ELEV = 4946.07
LP STA = 24+73.58
PVI STA = 24+73.58
PVI ELEV = 4945.98
BCVS: 24+36.08
BVCE: 4946.17
ECVS: 25+11.08
EVCE: 4946.17
A.D. = 1.00
K = 75.00
4948.16
4947.85
4947.35
4946.85
4946.35
4946.12
4946.61
4947.82
4947.94
4948.07
4948.17
4948.10
4947.97
4947.72
4947.60
4947.47
4947.22
4947.10
4946.97
4946.72
4946.60
4946.47
4946.22
4946.11
4946.07
4946.24
4946.36
4946.49
4946.74
4946.86
4946.99
PROPOSED GRADE (TO REMAIN HIGH
AS EMERGENCY OUTFALL ELEVATION
FOR SITE IS ESTIMATED TO BE
APPROXIMATELY 4945')
EXISTING GROUND
PROPOSED GRADE EXISTING GROUND
NORTH
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
LINE
MATCH
STA
19+00
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
CENTERLINE
STREET C
SCALE : 1" = 40' (H) 1" = 5' (V)
MATCH LINE SEE SHEET R6 STA 19+00
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
R7
PLAN & PROFILE
STREET C
21
C
C
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
PROPOSED 2'
CONCRETE PAN
BP: 10+00.00
PC: 11+17.39
PT: 16+51.60
BLOCK 9
BLOCK 13
BLOCK 9
TRACT F
PROPOSED DRIVE
OVER CURB AND
GUTTER
PROPOSED STORM DRAIN
4940
4945
4950
4955
4960
4965
4940
4945
4950
4955
4960
4965
9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00
-2.20%
-4.00%
0.50%
2.00%
0.50%
-0.50%
-2.00%
PVI STA = 16+20.45
PVI ELEV = 4945.54
PVI STA = 18+72.78
PVI ELEV = 4947.55
50.0' VC
PVI STA = 15+70.45
PVI ELEV = 4946.54
BVCS: 15+45.45
BVCE: 4946.67
EVCS: 15+95.45
EVCE: 4946.04
A.D. = 1.50
K = 33.33
50.0' VC
PVI STA = 16+70.45
PVI ELEV = 4946.54
BVCS: 16+45.45
BVCE: 4946.04
EVCS: 16+95.45
EVCE: 4946.67
A.D. = 1.50
K = 33.33
105.0' VC
PVI STA = 14+23.23
PVI ELEV = 4947.28
BCVS: 13+70.73
BVCE: 4949.38
ECVS: 14+75.73
EVCE: 4947.02
A.D. = 3.50
K = 30.00
-2.20%
-4.00%
0.50%
2.00%
0.50%
-0.50%
-2.00%
PVI STA = 10+00.00
PVI ELEV = 4963.96
PVI STA = 18+72.78
PVI ELEV = 4947.55
PVI STA = 16+20.45
PVI ELEV = 4945.54
50.0' VC
PVI STA = 15+70.45
PVI ELEV = 4946.54
BVCS: 15+45.45
BVCE: 4946.67
EVCS: 15+95.45
EVCE: 4946.04
A.D. = 1.50
K = 33.33
50.0' VC
PVI STA = 16+70.45
PVI ELEV = 4946.54
BVCS: 16+45.45
BVCE: 4946.04
EVCS: 16+95.45
EVCE: 4946.67
A.D. = 1.50
K = 33.33
105.0' VC
PVI STA = 14+23.23
PVI ELEV = 4947.28
BCVS: 13+70.73
BVCE: 4949.38
ECVS: 14+75.73
EVCE: 4947.02
A.D. = 3.50
K = 30.00
4963.96
4960.21
4956.21
4952.21
4948.35
4946.89
4945.95
4946.69
4947.19
4963.21
4962.21
4961.21
4959.21
4958.21
4957.21
4955.21
4954.21
4953.21
4951.21
4950.21
4949.21
4947.70
4947.25
4947.02
4946.77
4946.64
4946.39
4945.63
4946.13
4946.50
4946.82
4946.94
4947.07
4947.32
4947.44
4947.57
PROPOSED GRADE
EXISTING GROUND
PROPOSED GRADE EXISTING GROUND
PROPOSED RCP STORM
STA.=13+56.98
INV.=4944.24
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
NORTH
LINE
MATCH
STA
19+00
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
CENTERLINE
STREET C
SCALE : 1" = 40' (H) 1" = 5' (V)
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
C
C
R6
PLAN & PROFILE
STREET C
20
MATCH LINE SEE SHEET R7 STA 19+00
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
9' UTILITY EASEMENT
STA. = 25+54.57
(STREET B)
STA. = 24+82.77
(STREET A)
EP: 25+54.57
PC: 20+14.52
PC: 22+55.70
PT: 20+69.50
PT: 24+37.18
TRACT R
TRACT T DUA&EAE
DUE
TRACT J
BLOCK 16
BLOCK 16
BLOCK 5
BLOCK 6
BLOCK 16
PROPOSED STORM DRAIN
TRACT I
"STOP" SIGN w/
STREET NAMES
STREET B2
4940
4945
4950
4955
4960
4965
4940
4945
4950
4955
4960
4965
17+50 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+75
2.20%
0.50%
6.00%
2.00%
PVI STA = 25+54.57
PVI ELEV = 4962.87
PVI STA = 25+40.74
PVI ELEV = 4962.57
80.0' VC
PVI STA = 24+41.74
PVI ELEV = 4960.59
BVCS: 24+01.74
BVCE: 4958.19
EVCS: 24+81.74
EVCE: 4961.39
A.D. = 4.00
K = 20.00
105.0' VC
PVI STA = 22+90.50
PVI ELEV = 4951.52
BCVS: 22+38
BVCE: 4951.25
ECVS: 23+43
EVCE: 4954.67
A.D. = 5.50
K = 19.09
4949.06
4949.56
4950.06
4950.56
4951.06
4952.57
4958.09
4961.75
4948.94
4949.19
4949.31
4949.44
4949.69
4949.81
4949.94
4950.19
4950.31
4950.44
4950.69
4950.81
4950.94
4951.19
4951.35
4951.80
4953.67
4955.09
4956.59
4959.45
4960.50
4961.24
4962.25
4962.77
PROPOSED GRADE EXISTING GROUND
PROPOSED GRADE
EXISTING GROUND
15" RCP
STA.=23+56.12
INV.=4946.65
NORTH
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
LINE
MATCH
STA
17+50
NORTH
LINE
MATCH
STA
20+00
LINE
MATCH
STA
20+00
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
CENTERLINE
STREET B2
SCALE : 1" = 40' (H) 1" = 5' (V)
MATCH LINE SEE SHEET R4 STA 17+50
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
B B
B2
R5
PLAN & PROFILE
STREET B & STREET B2
19
CENTERLINE
STREET B
SCALE : 1" = 40' (H) 1" = 5' (V)
4935
4940
4945
4950
4955
4960
4935
4940
4945
4950
4955
4960
9+75 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+50
4945.76
4946.26
4946.76
4947.26
4947.76
4948.07
4947.50
4948.56
4945.89
4946.01
4946.14
4946.39
4946.51
4946.64
4946.89
4947.01
4947.14
4947.39
4947.51
4947.64
4947.89
4948.01
4948.13
4947.70
4947.19
4947.39
4947.98
4948.29
4948.44
4948.69
2.20%
-2.20%
2.00%
0.50%
-2.00%
0.50%
PVI STA = 10+00.00
PVI ELEV = 4945.76
PVI STA = 15+47.69
PVI ELEV = 4947.25
PVI STA = 15+50.69
PVI ELEV = 4947.18
PVI STA = 15+53.69
PVI ELEV = 4947.25
PVI STA = 15+67.52
PVI ELEV = 4947.55
PVI STA = 15+81.35
PVI ELEV = 4947.25
PVI STA = 15+84.35
PVI ELEV = 4947.18
PVI STA = 15+87.35
PVI ELEV = 4947.25
50.0' VC
HP ELEV = 4948.15
HP STA = 14+82.69
PVI STA = 14+97.69
PVI ELEV = 4948.25
BVCS: 14+72.69
BVCE: 4948.12
EVCS: 15+22.69
EVCE: 4947.75
A.D. = 2.50
K = 20.00
50.0' VC
PVI STA = 16+37.35
PVI ELEV = 4948.25
BVCS: 16+12.35
BVCE: 4947.75
EVCS: 16+62.35
EVCE: 4948.37
A.D. = 1.50
K = 33.33
PROPOSED GRADE
EXISTING GROUND EXISTING GROUND
PROPOSED GRADE
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
NORTH
LINE
MATCH
STA
17+50
CENTERLINE
STREET B
SCALE : 1" = 40' (H) 1" = 5' (V)
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
MATCH LINE SEE SHEET R5 STA 17+50
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
B B
B2
R4
PLAN & PROFILE
STREET B
18
SEE SHEET
R11
"STOP" SIGN w/
STREET NAMES
4950
4955
4960
4965
4970
4975
4950
4955
4960
4965
4970
4975
24+00 25+00 26+00 27+00 28+00 29+00
EXISTING GROUND
PROPOSED GRADE
1.86%
-2.00%
PVI STA = 28+28.60
PVI ELEV = 4955.96
PVI STA = 28+32.61
PVI ELEV = 4955.86
PVI STA = 28+36.62
PVI ELEV = 4955.96
PVI STA = 28+61.66
PVI ELEV = 4956.42
4964.53
4964.03
4963.53
4963.03
4962.53
4962.03
4961.53
4961.03
4960.53
4960.03
4959.53
4959.03
4958.53
4958.03
4957.53
4957.03
4956.53
4956.03
4956.21
PROPOSED GRADE EXISTING GROUND
NORTH
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
LINE
MATCH
STA
24+00
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
MATCH LINE SEE SHEET R2 STA 24+00
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
A
A
R3
PLAN & PROFILE
STREET A
17
A
CENTERLINE
STREET A
SCALE : 1" = 40' (H) 1" = 5' (V)
4980
4955
4960
4965
4970
4975
4980
16+75 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00
EXISTING GROUND
PROPOSED GRADE
4969.56
4967.30
4965.30
4963.94
4965.00
4965.50
4965.95
4968.89
4968.31
4967.80
4966.80
4966.30
4965.80
4964.80
4964.30
4963.80
4964.42
4964.73
4964.87
4965.12
4965.25
4965.37
4965.62
4965.75
4965.87
4965.84
4965.52
4965.03
-2.00%
2.00%
0.50%
-3.00%
-2.00%
PVI STA = 19+80.94
PVI ELEV = 4963.68
PVI STA = 19+83.94
PVI ELEV = 4963.61
PVI STA = 19+86.94
PVI ELEV = 4963.68
50.0' VC
PVI STA = 20+36.94
PVI ELEV = 4964.68
BVCS: 20+11.94
BVCE: 4964.18
EVCS: 20+61.94
EVCE: 4964.81
A.D. = 1.50
K = 33.33
75.0' VC
HP ELEV = 4965.95
HP STA = 22+98.78
PVI STA = 23+21.28
PVI ELEV = 4966.10
BVCS: 22+83.78
BVCE: 4965.92
EVCS: 23+58.78
EVCE: 4965.35
A.D. = 2.50
K = 30.00
75.0' VC
PVI STA = 17+25.00
PVI ELEV = 4968.80
BCVS: 16+87.50
BVCE: 4969.93
ECVS: 17+62.50
EVCE: 4968.05
A.D. = 1.00
K = 75.00
PROPOSED GRADE EXISTING GROUND
NORTH
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
LINE
MATCH
STA
16+75
LINE
MATCH
STA
24+00
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
MATCH LINE SEE SHEET R1 STA 16+75
MATCH LINE SEE SHEET R3 STA 24+00
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
A
A
R2
PLAN & PROFILE
STREET A
16
A
CENTERLINE
STREET A
SCALE : 1" = 40' (H) 1" = 5' (V)
BVCE: 4971.24
EVCS: 16+60.42
EVCE: 4970.74
A.D. = 5.00
K = 20.00
75.0' VC
PVI STA = 13+67.39
PVI ELEV = 4967.38
BCVS: 13+29.89
BVCE: 4967.19
ECVS: 14+04.89
EVCE: 4968.13
A.D. = 1.50
K = 50.00
PROPOSED GRADE EXISTING GROUND
∆
∆
STA. = 16+00.42
(STREET A)
STA. = 10+00.00
(FALLEN BRANCH DR)
53'
ROW
30'
FL-FL
30'
FL-FL
53'
ROW
STREET A
STREET A
LOT 1
LOT 8
LOT 6
LOT 7
LOT 12
LOT 16
LOT 15
LOT 14
LOT 13 LOT 10
LOT 11
LOT 9
LOT 13 LOT 14
LOT 11
LOT 12
LOT 10
LOT 9
LOT 7
LOT 8
LOT 6
LOT 5
LOT 3
LOT 2
LOT 4
LOT 1
TRACT A
DRAINAGE
EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
4.5' SIDEWALK
4.5' SIDEWALK
9' UTILITY EASEMENT
4.5' SIDEWALK
BP: 10+00.00
PC: 13+04.89
PT: 11+03.74
PT: 14+29.89
9' UTILITY EASEMENT
4.5' SIDEWALK
FALLEN BRANCH DR
SEE SHEET
R9
PROPOSED DRIVE OVER
CURB AND GUTTER
PROPOSED DRIVE OVER
CURB AND GUTTER
BLOCK 12
BLOCK 10
BLOCK 11
BLOCK 10
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
NORTH
LINE
MATCH
STA
16+75
CENTERLINE
STREET A
SCALE : 1" = 40' (H) 1" = 5' (V)
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE.
IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING
LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL TRAILS AT MAXIMUM SPACING OF 50
FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH TOWN STREET REPAIR STANDARDS.
6. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. PARKWAY WIDTH SHOWN ON THIS SHEET IS MEASURED FROM BACK OF CURB TO
FACE OF WALK
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
MATCH LINE SEE SHEET R2 STA 16+75
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
A
A
A
R1
PLAN & PROFILE
STREET A
15
E
E
E
E
E E
E
E
E
E
E E
E
E
12" W
12" W
12" W
12" W
16" W
16" W
16" W 16" W
16" W
16" W
16" W
16" W
16" W
16" W 16" W 16" W 16" W 16" W 16" W
CTV
CTV
CTV
CTV CTV
CTV
CTV
CTV
CTV
CTV
CTV
CTV
G
FO
G
X
X
SS
SS SS
ST
T
ELEC
ELEC
VAULT
ELEC
ELEC
B M
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
8" W 8" W
IRR
IRR IRR
IRR
IRR
T S
T S
T S
T S
E E
E E E E
E
E
E
E
BLOCK 2
TRACT N
DU&PAE
LOT 17 LOT 18 LOT 19 LOT 20 LOT 21 LOT 22
LOT 1
LOT 2
LOT 3
LOT 4
LOT 6
TRACT M
LOT 5
15' EASEMENT
REC. NO. 20140004033
PLANNED
HANSEN FARM
ROSEN DRIVE
ZEPHYR RD (PLANNED)
TIMBERLINE ROAD
5' WALK
5' WALK
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
G6
GRADING PLAN
14
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
LEGEND:
ST
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT
THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS.
9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK
ALONG DITCH LATERAL.
10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT.
36.25
(36.25)
2.0%
NOTES:
PROPOSED SLOPES
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPERTY BOUNDARY
PROPOSED CURB AND GUTTER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM INLET
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED RIGHT OF WAY
NATURAL HABITAT BUFFER ZONE (NHBZ)
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
MATCHLINE-SEE SHEET G5
G1
G2
G3
G4
G5 G6
G
G G
G
G
G
G
G
G G
G
G
T
T
T
T
T
T
T
T
T
ST
W
W
W
W
W
W
W
W
W W
W W
W
W W
STREET D
STREET B2
STREET A
ZEPHYR RD
STREET B
NATURAL
HABITAT
BUFFER
ZONE
6' UTILITY EASEMENT
6' UTILITY
EASEMENT
53' ROW
53' ROW
53' ROW
76' ROW
54' FL-FL
30' FL-FL
30' FL-FL
30' FL-FL
20'
20'
15' EASEMENT
REC. NO. 20140004033
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
20'
20'
6' UTILITY EASEMENT
BLOCK 1
BLOCK 1
BLOCK 13
BLOCK 14
BLOCK 14
BLOCK 15
BLOCK 15 BLOCK 16
BLOCK 2
BLOCK 3
BLOCK 16
BLOCK 5
BLOCK 12
BLOCK 6
BLOCK 6
BLOCK 4
LOT 16
TRACT N
DU&PAE
LOT 14 LOT 15 LOT 17 LOT 18 LOT 19
LOT 12
LOT 13
LOT 10
LOT 11
LOT 9
LOT 8
LOT 7
LOT 6
LOT 12 LOT 7
LOT 16 LOT 15 LOT 14 LOT 13 LOT 11 LOT 10 LOT 9 LOT 8
TRACT L
DU&PAE
LOT 10
LOT 9 LOT 5 LOT 3
TRACT M
LOT 8 LOT 6 LOT 4
LOT 1
LOT 2
LOT 7
LOT 3
LOT 8
LOT 7
LOT 6
LOT 5
LOT 4
LOT 1
LOT 2
LOT 16
LOT 1
LOT 2
LOT 6
LOT 3
LOT 7
LOT 4
LOT 5
LOT 4
LOT 3
TRACT T
DUE
LOT 1
LOT 2
LOT 1
LOT 3
LOT 2
TRACT J
LOT 1
LOT 7
TRACT F
LOT 9
LOT 10
LOT 3
LOT 6
LOT 7
TRACT Q
LOT 5
LOT 4
LOT 1
LOT 2
LOT 8
LOT 12
LOT 89
LOT 10
LOT 11
LOT 2
LOT 4
LOT 3
LOT 5
LOT 9
LOT 6
LOT 7
LOT 8
LOT 12
LOT 10
LOT 11
LOT 13
LOT 3
LOT 6
LOT 5
LOT 4
LOT 2
LOT 7
LOT 8
LOT 9
LOT 9 LOT 8
LOT 4
LOT 10 LOT 7 LOT 6
TRACT I
LOT 8
LOT 9
TRACT H
LOT 5
LOT 4
LOT 5
LOT 6
LOT 7
LOT 12
TRACT G
LOT 10
LOT 11
LOT 13
LOT 14
LOT 1
LOT 2
LOT 4
LOT 3
LOT 10
LOT 18
LOT 17
LOT 16
LOT 15
LOT 14
PROPOSED STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
DETENTION
POND
TRACT C
FUTURE PARK
DITCH LATERAL
TRACT D
DUA&EAE
TRACT S
DUA&EAE
ROSEN DRIVE
PROPOSED
STORM DRAIN
6' TRAIL
6' TRAIL
5' WALK
5' WALK
5' WALK
5' WALK
5' WALK
5' WALK
RED WILLOW DRIVE
LOT 19
TRACT V
TRACT E
DGE
LOT 11
TRACT K
DUA&EAE
TRACT R
DUA&EAE
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
G5
GRADING PLAN
13
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
LEGEND:
ST
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT
THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS.
9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK
ALONG DITCH LATERAL.
10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT.
36.25
(36.25)
2.0%
NOTES:
PROPOSED SLOPES
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPERTY BOUNDARY
PROPOSED CURB AND GUTTER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM INLET
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED RIGHT OF WAY
NATURAL HABITAT BUFFER ZONE (NHBZ)
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
MATCHLINE-SEE SHEET G3
MATCHLINE-SEE SHEET G4
MATCHLINE-SEE SHEET G6
G1
G2
G3
G4
G5 G6
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
20'
15' UTILITY EASEMENT
REC. NO. 20110070565
30' UTILITY EASEMENT
REC. NO. 20100004033
UD
UD
UD
UD
UD
UD
UD
UD UD
BLOCK 12
BLOCK 12
LOT 1
LOT 2
LOT 3
LOT 4
LOT 15
LOT 14
LOT 6
LOT 12
LOT 11
LOT 10
LOT 9
LOT 8
LOT 7
LOT 3
LOT 5
LOT 4
LOT 1
LOT 2
LOT 15
LOT 14
LOT 13
LOT 3
LOT 13
LOT 2
DITCH LATERAL
PLANNED
PEDESTRIAN BRIDGE
CROSSING
PLANNED
HANSEN FARM
6' TRAIL
TRACT U
OPEN SPACE
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
G4
GRADING PLAN
12
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
LEGEND:
ST
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT
THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS.
9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK
ALONG DITCH LATERAL.
10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT.
36.25
(36.25)
2.0%
NOTES:
PROPOSED SLOPES
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPERTY BOUNDARY
PROPOSED CURB AND GUTTER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM INLET
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED RIGHT OF WAY
NATURAL HABITAT BUFFER ZONE (NHBZ)
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
MATCHLINE-SEE SHEET G5
MATCHLINE-SEE SHEET G2
G1
G2
G3
G4
G5 G6
LOT 9
LOT 8
LOT 2
LOT 3
LOT 1
LOT 5
LOT 4
LOT 3
LOT 1
LOT 4
LOT 9
LOT 8
LOT 7
LOT 6
LOT 5
LOT 10
PROPOSED
STORM DRAIN
PROPOSED 2'
CONCRETE PAN
10.7%
10.5%
TRACT A
DRAINAGE
EASEMENT
DETENTION
POND
PROPOSED
FOREBAY
PROPOSED
SIDEWALK
CULVERT
PROPOSED
FOREBAY
PROPOSED
FOREBAY
PROPOSED
SIDEWALK
CULVERT
PROPOSED
SIDEWALK
CHASE
5' WALK
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
G3
GRADING PLAN
11
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
LEGEND:
ST
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT
THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS.
9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK
ALONG DITCH LATERAL.
10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT.
36.25
(36.25)
2.0%
NOTES:
PROPOSED SLOPES
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPERTY BOUNDARY
PROPOSED CURB AND GUTTER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM INLET
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED RIGHT OF WAY
NATURAL HABITAT BUFFER ZONE (NHBZ)
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
MATCHLINE-SEE SHEET G2
MATCHLINE-SEE SHEET G5
G1
G2
G3
G4
G5 G6
30' EASEMENT
REC. NO. 20110070565
67' EASEMENT
REC. NO. 20140004033
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
BLOCK 11
BLOCK 9
BLOCK 10
BLOCK 10
BLOCK 11
LOT 2
LOT 6
LOT 5
LOT 2 LOT 3
LOT 1 LOT 4
LOT 1
LOT 3
LOT 8
LOT 6
LOT 5
LOT 7
LOT 12
LOT 17
LOT 18
LOT 19
LOT 16
LOT 15
LOT 14
LOT 13
LOT 10
LOT 11
LOT 9
LOT 14
LOT 13
LOT 11
LOT 12
LOT 10
LOT 9
LOT 7
LOT 8
LOT 4
LOT 12
LOT 13
LOT 10
LOT 11
LOT 2
5.4%
8.5%
19.8%
7.7%
4.2%
3.7%
16.0%
PROPOSED STORM DRAIN
PROPERTY
BOUNDARY (TYP.)
DETENTION
POND
TRACT A
DRAINAGE
EASEMENT
EXISTING 36"
IRON PIPE STORM
EMERGENCY
SPILLWAY LOCATION
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
G2
GRADING PLAN
10
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
LEGEND:
ST
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT
THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS.
9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK
ALONG DITCH LATERAL.
10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT.
36.25
(36.25)
2.0%
NOTES:
PROPOSED SLOPES
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPERTY BOUNDARY
PROPOSED CURB AND GUTTER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM INLET
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED RIGHT OF WAY
NATURAL HABITAT BUFFER ZONE (NHBZ)
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
MATCHLINE-SEE SHEET G1
MATCHLINE-SEE SHEET G4
MATCHLINE-SEE SHEET G3
G1
G2
G3
G4
G5 G6
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
G1
GRADING PLAN
9
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
LEGEND:
ST
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT
THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS.
9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK
ALONG DITCH LATERAL.
10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT.
36.25
(36.25)
2.0%
NOTES:
PROPOSED SLOPES
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPERTY BOUNDARY
PROPOSED CURB AND GUTTER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM INLET
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED RIGHT OF WAY
NATURAL HABITAT BUFFER ZONE (NHBZ)
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
MATCHLINE-SEE SHEET G2
G1
G2
G3
G4
G5 G6
SS SS
SS SS
LID
VAULT
F.O.
W W W
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E
E
E
E
E
E
E
E
E
T
T
T T
T
T
T T
T
T
T
G
G
G
G
G
G
T
T
T
W
W
W
W
W W
W
STREET A
STREET B
STREET C
STREET D
STREET B2
STREET A
ZEPHYR RD
FALLEN BRANCH DR
STREET F
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
BLOCK 6
BLOCK 1
BLOCK 16
BLOCK 5
BLOCK 4
BLOCK 12
BLOCK 12
BLOCK 10
BLOCK 10
BLOCK 11
BLOCK 7
BLOCK 9
BLOCK 8
BLOCK 6
BLOCK 9
BLOCK 9
BLOCK 13
BLOCK 14
BLOCK 15
BLOCK 2
BLOCK 3
TRACT S
DUA&EAE
TRACT D
DUA&EAE
TRACT R
DUA&EAE
TRACT B
DGE TRACT N
DU&PAE
TRACT K
DUA&EAE
TRACT O
DU&PAE
TRACT V
TRACT T
DUE
TRACT F
TRACT P TRACT Q
TRACT G
TRACT L
DU&PAE
TRACT M
TRACT A
DRAINAGE
EASEMENT
TRACT I
TRACT H
TRACT J
TRACT C
FUTURE PARK
BLOCK 8
12" W
12" W
X
SS
VAULT
ELEC
X
X
X
X
X
IRR
UD
UD
UD
PLANNED HANSEN
FARM
PLANNED HANSEN
FARM
PROPOSED
STORM DRAIN
DETENTION
POND
DETENTION
POND
RED WILLOW
DRIVE
TRACT U
OPEN SPACE
TRACT E
DGE
X
X
X
X
EXISTING FENCE
TO REMAIN
UNION PACIFIC RAILROAD
DITCH LATERAL
PROPERTY
BOUNDARY
(TYP.)
X
X
X
PLANNED HANSEN
FARM
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
OG1
GRADING PLAN
OVERALL
8
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
MATCHLINE-THIS SHEET
MATCHLINE-THIS SHEET
LEGEND:
ST
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING
NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING
ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL
UNKNOWN UNDERGROUND UTILITIES.
2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY
INFORMATION.
3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE
FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED.
4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS
REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM.
5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES
SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE.
6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88
(UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES.
7. CONSTRUCTION ON DITCH LATERAL WILL BE LIMITED FROM OCTOBER 1 TO MAY 1
WHEN NOT IN USE.
8. NO CUTTING OF EARTHWORK WITHIN 5 FEET OF DITCH LATERAL BANK EXCEPT AT
THE LOCATIONS OF THE 2 STREET CROSSINGS AND 2 WEIRS.
9. NO DISTURBANCE OF VEGETATED ROOT SYSTEM WITHIN 5 FEET OF TOP OF BANK
ALONG DITCH LATERAL.
10. EXISTING CONTOURS ON HANSEN FARM IS AS PLANNED WITH DEVELOPMENT.
36.25
(36.25)
2.0%
NOTES:
PROPOSED SLOPES
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPERTY BOUNDARY
PROPOSED CURB AND GUTTER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM INLET
PROPOSED STORM SEWER
EXISTING STORM SEWER
LIMITS OF DEVELOPMENT LOD
PROPOSED RIGHT OF WAY
NATURAL HABITAT BUFFER ZONE (NHBZ)
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
FO
FO
FO
FO
FO
E
E
E
T
T
T
T
T
T
T
T
T
T
T T
T T T T T
T
T
T
T
T
G
G
G
G
G
G
G
G
G
G G
T
T
T
T
T
T
W
W
W
W
W
W
W W W
W
W
W
W
W
T
E
12" W
X
X
SS SS
V
AULT
ELEC
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
STREET B2
ZEPHYR RD
STREET A
NATURAL
HABITAT
BUFFER
ZONE
PLANNED
PEDESTRIAN
BRIDGE
PLANNED TEMP. FH
ASSEMBLY AND
REDUCER
PROPOSED
STORM DRAIN
9' UTILITY EASEMENT
9' UTILITY EASEMENT
6' UTILITY
EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
6' UTILITY
EASEMENT
53' ROW
53' ROW
76' ROW
54' FL-FL
30' FL-FL
30' FL-FL
LOT 9
LOT 1
LOT 2
LOT 6
LOT 3
LOT 7
LOT 4
LOT 5
LOT 4
LOT 3
LOT 1
LOT 19
LOT 18
LOT 17
LOT 16
LOT 15
LOT 14
LOT 13
LOT 12
LOT 16
LOT 84
LOT 22
LOT 21
LOT 20
LOT 19
LOT 18
LOT 17
LOT 3
LOT 15
LOT 14
LOT 12 LOT 13
LOT 10
LOT 11
LOT 9
LOT 8
LOT 7
TRACT V
LOT 5
LOT 4
LOT 1
LOT 2
LOT 1
LOT 2
LOT 3
LOT 1
LOT 10
LOT 11
LOT 4
LOT 6
LOT 12
LOT 7
LOT 9
LOT 11
LOT 15
LOT 16
LOT 8
LOT 10
LOT 13
LOT 14
TRACT L
DU&PAE
LOT 10
LOT 9
LOT 3
LOT 5
LOT 4
LOT 6
LOT 8
LOT 1
LOT 2
LOT 5
LOT 2
LOT 7
LOT 2
LOT 1
LOT 3
TRACT T
DUE
TRACT N
DU&PAE
TRACT K
DUA&EAE
TRACT O
DU&PAE
TRACT V
TRACT M
TRACT R
DUA&EAE
TRACT J
TRACT C
FUTURE PARK
BLOCK 12
BLOCK 16
BLOCK 5 BLOCK 4
BLOCK 6
BLOCK 1
BLOCK 2
BLOCK 3
EXISTING 10"
PVC SANITARY
SSMH 6
INV. IN=4937.49 (NW)
INV. OUT=4937.29 (SE)
FG=4965.95
SSMH 5
INV. IN=4936.10 (NW)
INV. OUT=4935.90 (SE)
FG=4960.45
SSMH 2-2C
INV. OUT=4936.82 (SW)
FG=4960.00
SSMH 4
INV. IN=4934.83 (NW)
INV. IN=4934.83 (E)
INV. OUT=4934.63 (SW)
FG=4956.42
EX. SSMH 1
INV. IN=4933.00 (N)
INV. OUT=4932.80 (S)
FG=4955.41
SSMH 2-2B
INV. IN=4936.46 (NE)
INV. OUT=4936.26 (S)
FG=4954.87
SSMH 3
INV. IN=4934.18 (NE)
INV. IN=4934.28 (SE)
INV. OUT=4934.08 (SW)
FG=4954.61
SSMH 2
INV. IN=4933.81 (NE)
INV. IN=4933.81 (NW)
INV. OUT=4933.71 (S)
FG=4954.48
SSMH 2-1
INV. IN=4934.43 (W)
INV. OUT=4934.23 (SE)
FG=4951.98
268.02 LF 8" PVC @ 0.40%
297.44 LF 8" PVC @ 0.40%
177.73 LF 8" PVC @ 0.40%
66.84 LF 8" PVC @ 0.40%
112.51 LF 8" PVC @ 0.40%
104.31 LF 8" PVC @ 0.40%
135.55 LF 8" PVC @ 0.40%
88.70 LF 8" PVC @ 0.40% 132.50 LF 8" PVC @ 0.40%
90.24 LF 8" PVC @ 0.40%
90.24 LF 8" PVC @ 0.40%
5' UTILITY EASEMENT
8' UTILITY EASEMENT
8' UTILITY EASEMENT
9' UTILITY
EASEMENT
LOT 6
5' UTILITY EASEMENT
PROPOSED FIRE
HYDRANT
184.14 LF 8" PVC @ 0.40%
SSMH 4-1
INV. IN=4935.77 (E)
INV. OUT=4935.57 (W)
FG=4962.49
196.90 LF 8" PVC @ 0.40%
SSMH 4-2
INV. OUT=4936.56 (W)
FG=4968.42
115.30 LF 8" PVC @ 0.40%
SSMH 3-1
INV. IN=4934.94 (S)
INV. OUT=4934.74 (NW)
FG=4954.63
70.72 LF 8" PVC @ 0.40%
SSMH 3-2
INV. IN=4935.42 (E)
INV. OUT=4935.22 (N)
FG=4955.72
239.60 LF 8" PVC @ 0.40%
SSMH 3-3
INV. IN=4936.58 (N)
INV. OUT=4936.38 (W)
FG=4957.77
75.27 LF 8" PVC @ 0.40%
SSMH 3-4
INV. IN=4937.08 (N)
INV. OUT=4936.88 (S)
FG=4959.68
47.21 LF 8" PVC @ 0.40%
SSMH 3-5
INV. OUT=4937.27 (S)
FG=4961.02
PROPOSED
STORM DRAINS
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
15' EASEMENT
REC. NO. 20140004033
30' EASEMENT
REC. NO. 20140004033
15' EASEMENT
REC. NO. 20110070565
15' EASEMENT
REC. NO. 20140004033
PLANNED 20'
GRAVEL ROAD
TO REMAIN
PLANNED 30'
SFCSD
EASEMENT
8" PVC WATER
PROPOSED
STORM DRAINS
8" PVC WATER
8" PVC WATER
8" PVC WATER
8" PVC WATER
TIE TO EXISTING
WATERLINE
EXISTING 10"
PVC SANITARY
DITCH LATERAL
PLANNED
HANSEN FARM
ZEPHYR RD (PLANNED)
ROSEN DRIVE
RED WILLOW
DRIVE
PROPOSED
AIR VAC
DETENTION
POND
PROPOSED 8"
WATER STUB
TRACT V
6' TRAIL
6' TRAIL
6' TRAIL
5' WALK
5' WALK
5' WALK
TRACT E
DGE
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
U3
UTILITY PLAN
7
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORMLINE
LEGEND:
NOTES:
W
G
T
E
EXISTING STORM SEWER
ST
PROPOSED ELECTRIC
EXISTING TELEPHONE
EXISTING GAS
PROPOSED UNDERDRAIN
EXISTING SANITARY SEWER SS
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
PROPOSED LOTLINE
RIGHT OF WAY
PROPERTY BOUNDARY
S
PROPOSED SEWER SERVICE
W
PROPOSED RESIDENTIAL WATER SERVICE
PROPOSED SUBDRAIN
UD
SD
EXISTING FIRE HYDRANT
PROPOSED STORMLINE
LIMITS OF DEVELOPMENT LOD
EASEMENT LINE
1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND
WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE
DATE OF CONSTRUCTION.
2. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT
COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS
CURRENT AT THE DATE OF CONSTRUCTION.
3. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL
SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND
WATER LINES.
4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM
COVER SHALL BE 6.0 FEET.
5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN BICYCLE OR VEHICLE WHEEL PATHS.
6. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
8. ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS.
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
MATCHLINE-SEE SHEET U2
U1
U1
U2 U3
53' ROW
53' ROW
53' ROW
53' ROW 30' FL-FL
30' FL-FL
30' FL-FL
30' FL-FL
LOT 8
LOT 9
LOT 12
LOT 11
LOT 10
LOT 9
LOT 8
LOT 7
LOT 1
LOT 2
LOT 3
LOT 12
LOT 13
LOT 10
LOT 11
LOT 1
LOT 2
LOT 3
LOT 4
LOT 5
LOT 6
LOT 7
LOT 15
LOT 11
LOT 9
LOT 10
LOT 12
LOT 74
LOT 13
LOT 14
LOT 17
LOT 16
LOT 3
LOT 6
LOT 7
LOT 82
LOT 5
LOT 4
LOT 1
LOT 2
LOT 8
LOT 12
LOT 10
LOT 11
LOT 15
LOT 13
LOT 14
LOT 1
LOT 2
LOT 4
LOT 3
LOT 5
LOT 9
LOT 6
LOT 7
LOT 8
LOT 12
LOT 10
LOT 11
LOT 13
LOT 3
LOT 6
LOT 5
LOT 4
LOT 2
LOT 10
LOT 7
LOT 7
LOT 6
TRACT S
DUA&EAE
TRACT D
DUA&EAE
LOT 1
LOT 10
LOT 4
LOT 8
LOT 9
LOT 6 LOT 5
LOT 11 LOT 10 LOT 9 LOT 8 LOT 7 LOT 5 LOT 4 LOT 3 LOT 2 LOT 1
LOT 13
LOT 14
LOT 12
LOT 11 LOT 9 LOT 8
LOT 2
LOT 10
LOT 9
LOT 8
LOT 2
LOT 3
LOT 1
LOT 5
LOT 4
LOT 3
LOT 1
LOT 4
LOT 7 LOT 6 LOT 3
LOT 4
LOT 9
LOT 8
LOT 7
LOT 6
LOT 5
TRACT F
TRACT P TRACT Q
TRACT G
TRACT S
DUA&EAE
TRACT D
DUA&EAE
TRACT B
DGE
TRACT I
TRACT H
BLOCK 9
BLOCK 13
BLOCK 14
BLOCK 15 BLOCK 16
BLOCK 13 BLOCK 14
BLOCK 8
BLOCK 8
BLOCK 7
BLOCK 7
BLOCK 15 BLOCK 16
BLOCK 6
SSMH 6
INV. IN=4937.49 (NW)
INV. OUT=4937.29 (SE)
FG=4965.95
SSMH 7
INV. IN=4938.88 (NW)
INV. OUT=4938.68 (SE)
FG=4963.96
SSMH 2-4C
INV. OUT=4939.58 (SW)
FG=4962.74
SSMH 2-5D
INV. OUT=4941.25 (SW)
FG=4959.51
SSMH 2-4B
INV. IN=4938.87 (NE)
INV. OUT=4938.67 (S)
FG=4953.02
SSMH 2-5C
INV. IN=4940.54 (NE)
INV. OUT=4940.44 (S)
FG=4952.39
SSMH 2-2A
INV. IN=4935.90 (N)
INV. OUT=4935.70 (S)
FG=4951.42
SSMH 2-2
INV. IN=4935.17 (S)
INV. IN=4935.17 (N)
INV. OUT=4934.97 (E)
FG=4950.68
SSMH 2-4A
INV. IN=4937.96 (N)
INV. OUT=4937.76 (S)
FG=4950.56
SSMH 2-3
INV. IN=4935.72 (W)
INV. OUT=4935.52 (N)
FG=4949.91
SSMH 2-4
INV. IN=4936.78 (W)
INV. IN=4936.88 (N)
INV. OUT=4936.68 (E)
FG=4949.11
SSMH 2-6B
INV. OUT=4940.20 (SW)
FG=4948.60
SSMH 2-5
INV. IN=4937.84 (W)
INV. IN=4937.94 (N)
INV. OUT=4937.74 (E)
FG=4947.55
SSMH 2-6A
INV. IN=4939.85 (NE)
INV. OUT=4939.65 (S)
FG=4947.48
SSMH 2-6
INV. IN=4939.18 (W)
INV. IN=4939.28 (N)
INV. OUT=4939.08 (E)
FG=4947.05
SSMH 2-5B
INV. IN=4939.73 (N)
INV. OUT=4939.63 (S)
FG=4947.03
SSMH 2-5A
INV. IN=4938.92 (N)
INV. OUT=4938.82 (S)
FG=4946.16
SSMH 2-7
INV. IN=4940.12 (NW)
INV. OUT=4940.02 (E)
FG=4946.03
SSMH 2-8
INV. OUT=4940.47 (SE)
FG=4944.90
297.44 LF 8" PVC @ 0.40%
88.70 LF 8" PVC @ 0.40%
209.78 LF 8" PVC @ 0.40% 309.03 LF 8" PVC @ 0.40% 241.00 LF 8" PVC @ 0.40% 241.00 LF 8" PVC @ 0.40%
86.95 LF 8" PVC @ 0.40%
132.50 LF 8" PVC @ 0.40%
90.24 LF 8" PVC @ 0.40%
90.24 LF 8" PVC @ 0.40%
221.20 LF 8" PVC @ 0.40%
177.93 LF 8" PVC @ 0.40%
177.93 LF 8" PVC @ 0.40%
221.20 LF 8" PVC @ 0.40%
177.63 LF 8" PVC @ 0.40%
177.63 LF 8" PVC @ 0.40%
177.63 LF 8" PVC @ 0.40%
93.35 LF 8" PVC @ 0.40%
87.27 LF 8" PVC @ 0.40%
9' UTILITY EASEMENT
20'
20'
20'
20'
8' UTILITY
EASEMENT
6' UTILITY EASEMENT
8' UTILITY
EASEMENT
8' UTILITY
EASEMENT
8' UTILITY
EASEMENT
5' UTILITY
EASEMENT
5' UTILITY
EASEMENT
5' UTILITY
EASEMENT
PROPOSED TEMP.
FIRE HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
PROPOSED FIRE
HYDRANT
TRACT A
DRAINAGE
EASEMENT
PROPOSED
AIR VAC
8" PVC WATER
8" PVC WATER
8" PVC WATER
8" PVC WATER
8" PVC WATER 8" PVC WATER
8" PVC WATER
8" PVC WATER
DETENTION POND
EDGE OF
WETLAND
PROPOSED
FOREBAY
PROPOSED
FOREBAY
PROPOSED
FOREBAY
5' WALK
5' WALK
5' WALK
5' WALK
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
U2
UTILITY PLAN
6
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORMLINE
LEGEND:
NOTES:
W
G
T
E
EXISTING STORM SEWER
ST
PROPOSED ELECTRIC
EXISTING TELEPHONE
EXISTING GAS
PROPOSED UNDERDRAIN
EXISTING SANITARY SEWER SS
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
PROPOSED LOTLINE
RIGHT OF WAY
PROPERTY BOUNDARY
S
PROPOSED SEWER SERVICE
W
PROPOSED RESIDENTIAL WATER SERVICE
PROPOSED SUBDRAIN
UD
SD
EXISTING FIRE HYDRANT
PROPOSED STORMLINE
LIMITS OF DEVELOPMENT LOD
EASEMENT LINE
1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND
WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE
DATE OF CONSTRUCTION.
2. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT
COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS
CURRENT AT THE DATE OF CONSTRUCTION.
3. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL
SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND
WATER LINES.
4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM
COVER SHALL BE 6.0 FEET.
5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN BICYCLE OR VEHICLE WHEEL PATHS.
6. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
8. ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS.
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
MATCHLINE-SEE SHEET U1
MATCHLINE-SEE SHEET U3
U1
U1
U2 U3
X
X
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E
E
E
E
E E
E
E
E
E
E
E
E
E
E
E
E
E
W
M
WM
WM WM
WM WM
WM
WM
WM
WM
WM
WM WM
WM
WM
WM
WM
WM
WM
WM
WM WM
WM WM
WM
WM
WM
WM WM
WM
WM
WM
WM
WM WM WM
WM WM
WM
WM
WM
WM
WM
UD
STREET A
FALLEN BRANCH DR
PROPOSED
FIRE HYDRANT
NATURAL
HABITAT
BUFFER
ZONE
PLANNED
PEDESTRIAN
BRIDGE
PROPOSED
STORM
DRAIN
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
6' UTILITY
EASEMENT
6' UTILITY
EASEMENT
30' FL-FL
53' ROW
59' ROW
36' FL-FL
LOT 6
LOT 8
LOT 7
LOT 3
LOT 5
LOT 4
LOT 1
LOT 2
LOT 3
LOT 8
LOT 6
LOT 5
LOT 7
LOT 12
LOT 17
LOT 18
LOT 19
LOT 16
LOT 15
LOT 14
LOT 13
LOT 10
LOT 11
LOT 9
LOT 14
LOT 13
LOT 11
LOT 12
LOT 10
LOT 9
LOT 7
LOT 8
LOT 6
LOT 5
LOT 2 LOT 3
LOT 1 LOT 4
LOT 4
BLOCK 11
BLOCK 10
BLOCK 12
BLOCK 10
8" PVC WATER
CONNECT TO
EXISTING 8" PVC
WATER
EXISTING 8"
PVC WATER
EXISTING 8"
PVC SANITARY
SSMH 8
INV. IN=4940.35 (NW)
INV. OUT=4940.15 (SE)
FG=4970.03
SSMH 9
INV. IN=4941.82 (NW)
INV. OUT=4941.62 (SE)
FG=4967.43
SSMH 10
INV. IN=4943.32 (W)
INV. OUT=4943.12 (SE)
FG=4965.57
SSMH 11
INV. OUT=4943.68 (E)
FG=4964.21
316.86 LF 8" PVC @ 0.40% 316.86 LF 8" PVC @ 0.40%
324.37 LF 8" PVC @ 0.40%
89.50 LF 8" PVC @ 0.40%
5' UTILITY EASEMENT
PROPOSED FIRE
HYDRANT
30' EASEMENT
REC. NO. 20110070565
67' EASEMENT
REC. NO. 20140004033
TRACT A
DRAINAGE
EASEMENT
DITCH LATERAL
PROPOSED
AIR VAC
15' EASEMENT
REC. NO. 20110070565
EXISTING
ANTENNA
8" PVC WATER
DITCH LATERAL
30' EASEMENT
REC. NO. 20140004033
8" PVC WATER
PLANNED
HANSEN FARM
PLANNED
HANSEN FARM
30' EASEMENT
REC. NO. 20140004033
15' EASEMENT
REC. NO. 20110070565
BLOCK 10
5' TRAIL
5' TRAIL
5' TRAIL
TRACT U
OPEN SPACE
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
U1
UTILITY PLAN
5
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORMLINE
LEGEND:
NOTES:
W
G
T
E
EXISTING STORM SEWER
ST
PROPOSED ELECTRIC
EXISTING TELEPHONE
EXISTING GAS
PROPOSED UNDERDRAIN
EXISTING SANITARY SEWER SS
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
PROPOSED LOTLINE
RIGHT OF WAY
PROPERTY BOUNDARY
S
PROPOSED SEWER SERVICE
W
PROPOSED RESIDENTIAL WATER SERVICE
PROPOSED SUBDRAIN
UD
SD
EXISTING FIRE HYDRANT
PROPOSED STORMLINE
LIMITS OF DEVELOPMENT LOD
EASEMENT LINE
1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND
WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE
DATE OF CONSTRUCTION.
2. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT
COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS
CURRENT AT THE DATE OF CONSTRUCTION.
3. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL
SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND
WATER LINES.
4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM
COVER SHALL BE 6.0 FEET.
5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN BICYCLE OR VEHICLE WHEEL PATHS.
6. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
8. ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS.
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
MATCHLINE-THIS SHEET
MATCHLINE-THIS SHEET
MATCHLINE-SEE SHEET U2
U1
U1
U2 U3
200.00' PUBLIC
ACCESS TRAIL
EASEMENT
ELEC
VAULT
ELEC
VAULT
ELEC
H
Y
D
S S
S
ELEC
E
ELEC
BRKR
X
X
X X X X X X X
X
X X
X
X
X
X
X
X X
X
X X X X
X
X
X
X
X
X
X
X X
X
X
X
X X X X X
X
X
X
SS
SS
SS SS
SS SS
LID
VAULT
F.O.
W W W
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E
E
E
E
E
E
E
E
E
T
T
T T
T
T
T T
T
T
T
G
G
G
G
G
G
T
T
T
W
W
W
W
W W
W
STREET A
STREET B
STREET C
STREET D
STREET B2
STREET A
ZEPHYR RD
FALLEN BRANCH DR
STREET F
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
NATURAL
HABITAT
BUFFER ZONE
PROPOSED
STORM DRAINS
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
DITCH LATERAL
PLANNED
PEDESTRIAN
BRIDGE
PEDESTRIAN BRIDGE
UNION-PACIFIC RAILROAD
BLOCK 2
BLOCK 1
BLOCK 3
BLOCK 7
BLOCK 8
BLOCK 6
BLOCK 9
BLOCK 13
BLOCK 14
BLOCK 15
BLOCK 16
BLOCK 5
BLOCK 12
BLOCK 12
BLOCK 10
BLOCK 11
TRACT S
DUA&EAE
TRACT D
DUA&EAE
TRACT N
DU&PAE
TRACT V
TRACT L
DU&PAE
TRACT M
TRACT A
DRAINAGE
EASEMENT
TRACT I
TRACT H
TRACT J
TRACT C
FUTURE PARK
TRACT B
DGE
TRACT F
TRACT P TRACT Q
TRACT G
PROPOSED
FIRE HYDRANT
PROPOSED 8" PVC
SANITARY SEWER
PROPOSED 8" PVC
SANITARY SEWER
PROPOSED 8" PVC
SANITARY SEWER
PROPOSED 8" PVC
SANITARY SEWER
PROPOSED 8" PVC
SANITARY SEWER
PROPOSED 8" PVC
SANITARY SEWER
PROPOSED 8" PVC
SANITARY SEWER
PROPOSED 8"
PVC WATER
PROPOSED 8"
PVC WATER
PROPOSED 8"
PVC WATER
PROPOSED 8"
PVC WATER PROPOSED 8"
PVC WATER
PROPOSED 8"
PVC WATER
PROPOSED 8"
PVC WATER
PROPOSED 8"
PVC WATER
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED TEMP.
FIRE HYDRANT
PLANNED
HANSEN FARM
KNOBBY PINE DR
FALLEN BRANCH DR
FLOATING LEAF DR
KNOBBY PINE DR
PROPOSED 8" PVC
SANITARY SEWER
TIE TO EXISTING 8"
WATERLINE
PLANNED
HANSEN FARM
DETENTION POND
PROPOSED
FIRE HYDRANT
PROPOSED 8"
WATER STUB
TIE TO EXISTING 8"
WATERLINE
TIE TO EXISTING
12" WATERLINE
TIE TO EXISTING 8"
SANITARY SEWER
PROPOSED
FIRE HYDRANT
PROPOSED
FIRE HYDRANT
PROPOSED
STORM DRAIN
DETENTION
POND
PROPOSED 8" PVC
SANITARY SEWER
PROPOSED 8"
PVC WATER
RED WILLOW
DRIVE
TRACT E
DGE
TRACT K
DUA&EAE
TRACT U
OPEN SPACE
TRACT T
DUE
TRACT R
DUA&EAE
X
X
X
X
X
X
X
DITCH LATERAL
UNION PACIFIC RAILROAD
PROPERTY
BOUNDARY (TYP.)
MAIL CREEK DITCH
KNOBBY PINE DR
FUTURE
PEDESTRIAN
BRIDGE
PLANNED
HANSEN FARM
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
OU1
UTILITY PLAN
OVERALL
4
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORMLINE
LEGEND:
NOTES:
W
G
T
E
EXISTING STORM SEWER
ST
PROPOSED ELECTRIC
EXISTING TELEPHONE
EXISTING GAS
PROPOSED UNDERDRAIN
EXISTING SANITARY SEWER SS
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
PROPOSED LOTLINE
RIGHT OF WAY
PROPERTY BOUNDARY
S
PROPOSED SEWER SERVICE
W
PROPOSED RESIDENTIAL WATER SERVICE
PROPOSED SUBDRAIN
UD
SD
EXISTING FIRE HYDRANT
PROPOSED STORMLINE
LIMITS OF DEVELOPMENT LOD
EASEMENT LINE
1. ALL WATERLINE CONSTRUCTION SHALL CONFORM TO THE FORT COLLINS-LOVELAND
WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS CURRENT AT THE
DATE OF CONSTRUCTION.
2. ALL SANITARY SEWER CONSTRUCTION SHALL CONFORM TO THE SOUTH FORT
COLLINS SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS
CURRENT AT THE DATE OF CONSTRUCTION.
3. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 10 FEET OF HORIZONTAL
SEPARATION AND 18 INCHES OF VERTICAL SEPARATION BETWEEN ALL SEWER AND
WATER LINES.
4. MINIMUM DEPTH OF COVER OVER WATER MAINS SHALL BE 5.0 FEET AND MAXIMUM
COVER SHALL BE 6.0 FEET.
5. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN BICYCLE OR VEHICLE WHEEL PATHS.
6. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
7. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE
NOT TO SCALE.
8. ALL WATER FITTINGS TO BE MECHANICALLY RESTRAINED PER FCLWD STANDARDS.
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
NORTH
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
MATCHLINE-THIS SHEET
MATCHLINE-THIS SHEET
Y
D
H
Y
D
W
TELE
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
H
Y
D
S S
S
ELEC
E
ELEC
BRKR
OHU
OHU
OHU
OHU
OHU OHU OHU OHU OHU
OHU OHU
OHU
X
X
X X X X X X X
X
X X
X
X
X
X X
X
X
X
X
X
X X
X
X X X X
X
X
X
X
X X
X
X X
X
X X X
X
X X
X
X X
X
X
X
X
X
X
X
X X
X
X
X
X X X
X X
X
X
X
X
X
X
X
SS
SS
SS SS
SS SS
LID
VAULT
F.O.
W W W
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
FO
E
E
E
E
E
E
E
E
E
T
T
T T
T
T
T T
T
T
T
G
G
G
G
G
G
T
T
T
W
W
W
W
W W
W
PLANNED TEMP.
FH ASSEMBLY TO
BE REMOVED
EXISTING
BUILDING TO BE
REMOVED
EXISTING WALL
TO BE REMOVED
EXISTING F/O
TO REMAIN
EXISTING ELECTRIC
TO REMAIN
15' EASEMENT
REC. NO. 20140004033
30' EASEMENT
REC. NO. 20140004033
EXISTING FENCE
TO BE REMOVED 15' EASEMENT
REC. NO. 20110070565
EXISTING
TELEPHONE LINE
TO REMAIN
EXISTING FENCE
TO BE REMOVED
EXISTING FENCE
TO REMAIN
EXISTING ELECTRIC
BREAKER TO REMAIN
30' EASEMENT
REC. NO. 20110070565
67' EASEMENT
REC. NO. 20140004033
EXISTING FENCE
TO REMAIN
60' EASEMENT
REC. NO. 20100010642
15' EASEMENT
REC. NO. 20110070565
EXISTING 24" CMP
STORM TO BE
REMOVED
PLANNED FIRE
HYDRANT TO
REMAIN
EXISTING SANITARY
MANHOLE TO REMAIN
TEMP. CONSTRUCTION
AND GRADING EASEMENT
REC. NO. 20140026007
EXISTING 12" PVC
SANITARY
EXISTING FIRE
HYDRANT TO
REMAIN
EXISTING 12" PVC
WATER
EDGE OF
WETLAND
EXISTING GRAVEL
ROAD TO BE
REMOVED
PLANNED 8"
PVC WATER
NATURAL
HABITAT
BUFFER
ZONE
PLANNED 10"
PVC SANITARY
PLANNED 20'
GRAVEL ROAD
TO REMAIN
PLANNED 30'
SFCSD
EASEMENT
PLANNED
TEMP. FIRE
HYDRANT TO
REMAIN
PLANNED
HANSEN FARM
PLANNED
24"x36" RCBC
BURLEY TREE DR
KNOBBY PINE DR
FALLEN BRANCH DR
FLOATING LEAF DR
ROSEN DRIVE
DITCH LATERAL
59'
ROW
36'
FL-FL
PLANNED PEDESTRIAN
BRIDGE CROSSING
50' DITCH BUFFER
(FROM TOP OF BANK)
54'
FL-FL
76'
ROW
PLANNED END OF ROAD
SIGNS TO BE REMOVED
PLANNED
HANSEN FARM
EXISTING TEMPORARY
FIRE HYDRANT TO BE
REMOVED
15' EASEMENT
REC. NO. 20140004033
EXISTING OVERHEAD
ELECTRIC TO BE
UNDERGROUND OR
REMOVED PER UTILITY
PROVIDER
UNION PACIFIC RAILROAD
17' UTILITY AND
ACCESS EASEMENT
REC. NO. 20110070565
REC. NO. 20140004033
TO BE VACATED
EXISTING EDGE OF
WATER AT TIME OF
SURVEY
PLANNED
PEDESTRIAN BRIDGE
EXISTING 36" IRON
PIPE TO REMAIN
PROJECT
BOUNDARY (TYP.)
RED WILLOW
DRIVE
X
X
X
X
X
X
X
EXISTING FENCE
TO REMAIN
EXISTING CONCRETE
IRRIGATION STRUCTURE
UNION PACIFIC RAILROAD
MAIL CREEK DITCH
DITCH LATERAL
PROPERTY
BOUNDARY
(TYP.)
FUTURE
HANSEN FARM
FO
FO
FO
FO
E
E
E
PLANNED
24"X36"
RCBC AND
CONCRETE
HEADWALL
EXISTING
GRAVEL ROAD
TO BE
REMOVED
PLANNED TEMPORARY
FIRE HYDRANT TO BE
REMOVED
PLANNED 8"
WATERLINE TO
REMAIN
59'
ROW
36'
FL-FL
EXISTING FIBER OPTIC
AND ELECTRIC LINES
TO REMAIN
30' EASEMENT
REC. NO. 20140004033
15' EASEMENT
REC. NO. 20110070565
OHU OHU
OHU
OHU
OHU
FO
FO
FO
FO
FO
T
T T
T
T
15' EASEMENT
REC. NO. 20140004033
PLANNED
24"X36"
RCBC AND
CONCRETE
HEADWALL
76'
ROW
54'
FL-FL
EXISTING
GRAVEL ROAD
TO BE
REMOVED
EXISTING FIBER OPTIC
AND ELECTRIC LINES
TO REMAIN
EXISTING OVERHEAD
ELECTRIC TO BE
UNDERGROUND OR
REMOVED PER UTILITY
PROVIDER
PLANNED
TEMPORARY
CONSTRUCTION
EASEMENT
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
EX1
AND DEMOLITION PLAN
EXISTING CONDITIONS
3
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
NORTH
EXISTING ELECTRIC E
LEGEND:
G
T
EXISTING STORM SEWER ST
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION,
REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF
FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT
WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS
RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL
ROAD AND CAN BE REACHED AT (970) 482-1249.
4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED
IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
7. ALL IMPROVEMENTS LABELED AS "PLANNED" ARE A PART OF THE HANSEN
PROJECT. DESIGN DETAILS FOR THESE IMPROVEMENTS CAN BE FOUND IN THE
HANSEN FARM UTILITY PLANS.
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROJECT BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
VAULT
ELEC
CONTROL
IRR
EXISTING TREES (TO BE REMOVED)
APPROXIMATE LIMITS OF CONCRETE/
ASPHALT REMOVAL OR MILL & OVERLAY
1. THE NATURAL HABITAT BUFFER ZONES ARE INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE
USES WITHIN THE NATURAL HABITAT BUFFER ZONES.
NATURAL HABITAT BUFFER ZONES
KEYMAP
B M
T
ELEC
ELEC
GAS
VAULT
ELEC
VAULT
ELEC
TRAFFIC
VAULT
C
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
VAULT
ELEC
ELEC
ELEC
B M
TELE
M
GAS
F.O.
MM
M F.O.
T S
T S
T S
T S
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
WM
MATCHLINE-THIS SHEET
MATCHLINE-THIS SHEET
Permit is obtained, if applicable.
23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction.
The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control
Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all
public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the
Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the
improvement if subsequent testing reveals an improper installation.
24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench
work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not
correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement
section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final
soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a
minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur
until the City of Fort Collins Engineer approves the final report.
25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter
flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must
certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be
noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets.
26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction.
For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be
stubbed to the property lines and marked so as to reduce the excavation necessary for building connections.
27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional
criteria for roads within these districts.
28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as
established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval.
29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any
tree removal requiring a permit.
30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and
security. Refer to OSHA Publication 2226, Excavating and Trenching.
31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The
the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way.
The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities.
32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins
Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor
moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed.
33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the
Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing
traffic access to and from the Development.
34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site
construction activities on Sundays or holidays, unless there is prior written approval by Larimer County.
35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on
these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise.
36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer
for clarification, and annotate the dimension on the as-built record drawings.
37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and
specifications, and a copy of any permits and extension agreements needed for the job.
38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or
specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately.
39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available
to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort
Collins Engineer.
40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as
well as the basis of bearings. The information shall be as follows:
PROJECT DATUM: NAVD88
BENCHMARK 2-02 EAST SIDE OF TIMBERLAND ROAD, 1/2 MILE NORTH OF TRILBY ROAD, ON THE MIDDLE CONCRETE PAD TO
AN ELECTRIC BOX.
ELEVATION: 4964.37
BENCHMARK 16-01 SOUTH SIDE OF WILLOW SPRINGS WAY APPROX. 50 FT. WEST OF THE INTERSECTION OF WILLOW
SPRINGS WAY AND TIMBERLINE ROAD ON THE SOUTHWEST CORNER OF A STORM INLET.
ELEVATION: 4956.98
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED
NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING
EQUATION SHOULD BE USED: NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19'
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE EAST LINE OF THE NORTHEAST QUARTER OF SECTION 7, AS BEARING SOUTH 00'00'53"
EAST (ASSUMED BEARING) AS MONUMENTED ON PLAT.
41. All stationing is based on centerline of roadways unless otherwise noted.
42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters,
landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored
in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements
and/or prior to the issuance of the first Certificate of Occupancy.
43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The
existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be
done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing
surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the
entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the
Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made.
44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before
construction, or to the grades and condition as required by these plans.
45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and
workmanship defects for a minimum period of two years from the date of acceptance.
47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage
structures and pipes, for the following private streets: N.A.
48. Approved Variances are listed as follows: N/A
CONSTRUCTION NOTES
A. Grading and Erosion Control Notes
1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc).
All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the
approved project schedule, construction plans, and erosion control report.
4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the
property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining
all erosion control facilities shown herein.
5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be
limited to the area(s) required for immediate construction operations, and for the shortest practical period of time.
6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened
condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils
in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required
temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County.
7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as
necessary in order to ensure the continued performance of their intended function.
b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control
inspector.
c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment
and debris from all drainage infrastructure and other public facilities.
9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public
rights of way, and make sure streets and walkways are cleaned at the end of each working day.
10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not
to cause their release into any waters of the United States.
11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening,
watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project
and before turning the maintenance over to the City/County or Homeowners Association (HOA).
13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any
pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete
truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are
necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and
federal regulations.
14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout
material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the
concrete washout material will be removed and properly disposed of prior to the area being restored.
15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement
whatever measures are determined necessary, as directed by the City.
B. Street Improvement Notes
1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed
here.
2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for
approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt).
The job mix shall be submitted for approval prior to placement of any asphalt.
3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing
edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean
construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the
subgrade has been inspected and approved by the City of Fort Collins Engineer.
5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting
rings are not allowed.
6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The
existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in
conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The
determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with
adjacent landowners such that future projects do not cut the new asphalt overlay work.
7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement)
and as per the Right-of-Way Work Permit traffic control plan.
8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of
asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain
properly.
9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a
full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will
be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than
50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall
not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as
determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface.
The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence
of an Inspector.
C. Traffic Signing and Pavement Marking Construction Notes
1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking
Construction Notes listed here.
2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5. All lane lines for concrete pavement should be epoxy paint.
6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and
placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of
striping and symbols.
7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10. All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies
identified during the field inspection must be corrected before the 2-year warranty period will begin.
12. The Developer installing signs shall be responsible for locating and protecting all underground utilities.
13. Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of
Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer
determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and
striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings).
15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
D. Storm Drainage Notes
1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of
onsite drainage facilities shall be the responsibility of the property owner(s).
2. All recommendations of the Preliminary Drainage and Erosion Control Report for Rennat Subdivision dated July 31, 2019 by Northern
Engineering Services, Inc., shall be followed and implemented.
3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by
submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at
least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by
submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed
prior to certification per the Development Agreement.
E. Utility Notes
1. All waterline construction shall conform to the Fort Collins-Loveland Water District Standard Construction Specifications current at the date
of construction.
2. All sanitary sewer construction shall conform to the South Fort Collins Sanitation District Standard Construction Specifications current at the
date of construction.
3. The contractor shall maintain a minimum of 10 feet of horizontal separation and 18 inches of vertical separation between all sewer and
water lines.
4. Minimum depth of cover over water mains shall be 5.0 feet and maximum cover shall be 6.0 feet.
5. Manhole rim elevations are to be adjusted to 1/4" below finished grade. If necessary, cone sections shall be rotated to prevent lids being
located within bicycle or vehicle wheel paths.
6. The size, type and location of all known underground utilities are approximate when shown on these drawings. It shall be the responsibility
of the contractor to verify the existence of all underground utilities in the area of the work. Before commencing new construction, the
contractor shall be responsible for locating all underground utilities and shall be responsible for all unknown underground utilities.
7. All water fittings and valves are only graphically represented and are not to scale.
CS2
CONSTRUCTION NOTES
GENERAL AND
2
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26
FROM FACE OF WALK
6.5' MIN FENCE SETBACK
FROM FACE OF WALK
3' MIN FENCE SETBACK
FROM CURB FLOWLINE
3' MIN FENCE SETBACK
FROM EDGE OF ALLEY
· ZEPHYR RD · STREET A
· STREET B
· STREET C
· STREET D
· FALLEN BRANCH DR
· STREET F
CONCRETE PAVEMNET CS1
COVER SHEET
1
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
JULY 2019
PROJECT
LOCATION
VICINITY MAP
NORTH
I hereby affirm that these final
construction plans were prepared
under my direct supervision, in
accordance with all applicable City
of Fort Collins and State of
Colorado standards and statutes,
respectively; and that I am fully
responsible for the accuracy of all
design. revisions, and record
conditions that I have noted on
these plans.
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CERTIFICATION STATEMENT:
Northern Engineering Services, Inc.
Project No. 1204-003
Date: February 19, 2019
ORIGINAL FIELD SURVEY BY:
CONTACT INFORMATION
PROJECT TEAM:
Danny Weber, PE
Northern Engineering Services, Inc.
301 North Howes Street, Sutie 100
Fort Collins, Colorado 80521
(970) 221-4158
Bob Tessely, PLS
Northern Engineering Services, Inc.
301 North Howes Street, Sutie 100
Fort Collins, Colorado 80521
(970) 221-4158
CONTACT INFORMATION
PROJECT TEAM:
JD Padillla
Post Modern Development
144 North Mason St., Suite 4
Fort Collins, Colorado 80524
(970) 407-7808
SHEET INDEX
ENGINEER ING
N O R T H E RN
ENGINEER ING
N O R T H E RN
UTILITY CONTACT LIST: *
UTILITY COMPANY PHONE NUMBER
1 CS1 COVER SHEET
2 CS2 GENERAL AND CONSTRUCTION NOTES
3 EX1 EXISTING CONDITIONS AND DEMOLITION PLAN
4 OU1 OVERALL UTILITY PLAN
5-7 U1-U3 UTILITY PLAN
8 OG1 OVERALL GRADING PLAN
9-14 G1-G6 GRADING PLAN
15-17 R1-R3 STREET A PLAN & PROFILE
18-19 R4-R5 STREET B PLAN & PROFILE
20-21 R6-R7 STREET C PLAN & PROFILE
22 R8 STREET D PLAN & PROFILE
## ## FALLEN BRANCH DR & STREET F PLAN & PROFILE
24-25 R10-R11 ZEPHYR RD PLAN & PROFILE
26 DR1 DRAINAGE EXHIBIT
A TRACT OF LAND LOCATED IN THE EAST HALF OF SECTION 7, TOWNSHIP 6 NORTH, RANGE 68 WEST OF
THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
RENNAT SUBDIVISION
PRELIMINARY UTILITY PLANS
OWNER/APPLICANT
SITE ENGINEER
SURVEYOR
GAS----------------- Xcel Energy-----------------------------------Stephanie Rich (970) 225-7857
ELECTRIC-------- City of Fort Collins Light & Power------- Austin Kreager (970) 224-6152
CABLE------------- Comcast--------------------------------------- Don Kapperman (970) 567-0245
TELECOM-------- CenturyLink Local Network--------------- William Johnson (970) 377-6401
WATER------------ Fort Collins-Loveland Water District---- Jay East (970) 226-3104
WASTEWATER- South Fort Collins Sanitation District--- Jay East (970) 226-3104
STORMWATER- City of Fort Collins Utilities---------------- Wes Lamarque (970) 416-2418
* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for
the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for
locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of
Colorado (UNCC) at 811 for additional information.
Cathy Mathis
TB Group
444 Mountain Avenue
Berthoud, Colorado 80513
(970) 532-5891
PLANNER/
LANDSCAPE ARCHITECT
PROJECT DATUM: NAVD88
BENCHMARK 2-02 EAST SIDE OF TIMBERLAND ROAD, 1/2 MILE NORTH OF TRILBY
ROAD, ON THE MIDDLE CONCRETE PAD TO AN ELECTRIC BOX.
ELEVATION: 4964.37
BENCHMARK 16-01 SOUTH SIDE OF WILLOW SPRINGS WAY APPROX. 50 FT. WEST OF
THE INTERSECTION OF WILLOW SPRINGS WAY AND TIMBERLINE ROAD ON THE
SOUTHWEST CORNER OF A STORM INLET.
ELEVATION: 4956.98
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM.
SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED DATUM (PRIOR
CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED
FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29
UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19'
BASIS OF BEARINGS
THE BASIS OF BEARINGS IS THE EAST LINE OF THE NORTHEAST QUARTER OF
SECTION 7, AS BEARING SOUTH 00°00'53" EAST (ASSUMED BEARING) AS
MONUMENTED ON PLAT.
PROJECT BENCHMARKS:
All changes, addendums, additions, deletions and
modifications to these drawings must be approved,
in writing, by the Fort Collins-Loveland
Water District and the South Fort Collins Sanitation District.
District Engineer Date
FORT COLLINS - LOVELAND
WATER DISTRICT
SOUTH FORT COLLINS
SANITATION DISTRICT
Sheet
RENNAT SUBDIVISION These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
REVIEW SET
E NGINEER ING
N O R T H E RN
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
of 26