Loading...
HomeMy WebLinkAboutDUTCH BROS - FDP190017 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE, LANDSCAPE & ELEVATIONS PLANS (3)Included N/A Titleblock Nameofprojectand/orsubdivision Legendwithsymbols,abbreviations,etc. VicinitymaporKeymap Typcialdrawingscales:1”=20’,30’,40’or50’ NorthArrowonallsheets Dateofpreparation Citysignatureblock Ditchcompanysignatureblock(ifapplicable) FP Onfinalplans:StampandsignatureofColoradolicensedProfessionalCivilEngineerinaccordance withColoradoStateStatutesandBoardRules Existingprominentfeatures(waterways,irrigationditches,vegetation,etc) Existingsiteinformation(buildingfootprints,parkinglots,roadways,streetnames) Existingboundarylinesoftheproperty,including:rightofwaylines,lotlinesandexisting easements Existingutilitieslocations Existingtopography(contoursshouldextend50'outsideofpropertyboundaryorshow relationshiptoadjacentproperties) Demolitioninformationshownandcalledoutonthisplan Existingprominentfeatures(waterways,ponds,majorutilities,irrigationditches,vegetationlines, trees,naturalhabitatbufferzones,etc) Existingandproposedsiteplaninformation(buildingfootprints,parkinglots,roadways,street names) Existingandproposedboundarylinesofthesubdivisionorproject,rightofwaylines,lotlines, easements Existingutilitieslocationswheredrainagedesignaffectstheexistingutility Existingandproposedcontours(contoursshouldextend50'outsideofpropertyboundaryorshow relationshiptoadjacentproperties) Easements:Proposeddrainageeasementsshownforpublicstormlines,detentionponds,outfall pipesfromponds,volumeͲbasedLIDsystems LID:TypeofLIDandlocationofLIDsystemsclearlyshownandcalledoutonthisplan. verifysubgradematerialdepthsmeetFCUminimumrequirements maxrunͲonratioforbioswales10:1;maxrunͲonratioforpavers3:1 forpavers:includeimperviousmembraneadjacenttobuildings underdrainincludedinthedesignandshownintheplans;minunderdrainsizeis4" inflowforebayorlevelspreaderincludedforraingardensandsandfilters reviewlandscapeplanforappropriateplantingsinraingardens,bioswales,sandfilters notreesinraingardens FP ErosioncontrolaroundperimeterofraingardensorotherLID'sͲNoteongradingplans:Please refertotheerosioncontrolplansheetsandreportfortemporarycontrolmeasuresand constructionsequencingthatshallbeusedinordertopreventloadingofthisLIDdrainagefacility withsedimentduringconstruction. Date: ProjectName: PDPandFPDrawingChecklist GeneralPlanRequirements ExistingConditionsand/orDemolitionPlan(ifapplicable) OverallGradingPlan Page1of3 Date: Included N/A ProjectName: PDPandFPDrawingChecklist Underdrains:horizontallocationsareshownandmakesenserelativetothesurfaceorsubsurface grading cleanoutsatbendsandtees FP invertelevationsshownatjunctions minimumpipesizeis4" Stormwateroutfallidentifiedontheplans Proposedflowarrowsandslopelabels Proposedspotelevations Proposedstormsewers,culverts,manholes,crossͲpans,other DetentionBasins:maxslopeindetentionbasins4:1 pipeoutlets(FES's)andoutletstructurestuckedintoembankmentsandnotstickingout reviewlandscapeplanforappropriateplantingsindetentionbasins notreesinswalecenterlines FGatleast6"belowFFelevation(variesdependingonsiteplans) maxslopeawayfrombuildings3:1 FP individuallotgradingdetails:FF's,MO's,lotlineswales,frontandbacklotgrades,gradebreaks FP typicallotgradingdetails ROWlines,propertylinesandeasementswithdimensionsshown Curbandgutter,crossͲpans,sidewalks(attachedordetached)andmediansshown Water,WastewaterandStormSewer:showtheexistingandproposedsystemlayoutsincluding sizesofallmains;aminimumhorizontalseparationof10'shallbemaintainedbetweenallutility mains DryUtilities:Existingandproposedgas,electric,telephone,cable,etc. Proposedprivatesubdrains(ifapplicable) Existingirrigationditchesshown Matchlineswithcorrespondingsheetnumbersreferenced Phasinglines(ifapplicable) FP size,typeandclassofallportionsofstormsewerwithlengthsmeasuredfrommanholecenters FP manholetype,diameters FP longitudinalstationing FP matchlineswithstationingandsheetnumbers FP phaselines(ifnecessary) FP existinggroundandproposedgroundshowninprofile FP Manholerimandinflow/outflowinvertelevations FP include100ͲyrHGL'sintheprofile FP includeallwetutilitycrossingsanddryutilitycrossingsintheprofile FP identifyeachsegmentofeachstormseweras"private"or"public" FP Aminimumverticalclearanceof18"shallbemaintainedwhencrossingallotherutilities. DetailedGradingPlan OverallUtilityPlan StormSewerPlanandProfileSheets Page2of3 Date: Included N/A ProjectName: PDPandFPDrawingChecklist FP ApplicableFCUstandardstormsewerdetails FP ApplicableFCUstandardLIDdetails FP Otherstormwaterdetailssuchas:emergencyspillway,concretepan,softpan,others? FP Detailsofspecialconnections,crossingsorconstructionspecifictothisproject FP Anymodifieddetailsareclearlylabeledordistinguishedfromthestandarddetails Notreesshallbeplantedwithin10'ofstormsewermains Noshrubsshallbeplantedwithin4'ofstormsewermains Verifythatthenotelistingtheseminimumseparationdistancesisincludedonthelandscapeplan. Allexistingeasementsshown Allproposeddrainageeasementsshown SiteandLandscapePlans Plat ConstructionDetailSheets Page3of3