Loading...
HomeMy WebLinkAboutFTC RAMS CROSSING WTE VERIZON - BDR180027 - SUBMITTAL DOCUMENTS - ROUND 4 - PLANSFTC RAMS CROSSING 808 W PROSPECT RD FORT COLLINS, COLORADO 80525 NEW ROOFTOP MACRO CONSTRUCTION DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS FROM SOUTH VAUGHN WAY MERGE ONTO 1-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W, KEEP RIGHT AT THE FORK TO CONTINUE ON I-270W, TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FT. COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W, TURN LEFT ONTO S COLLEGE AVE, TURN RIGHT ONTO W LAKE ST, TURN LEFT ONTO CENTRE AVE , TURN RIGHT ONTO W PROSPECT RD, SITE WILL BE ON YOUR RIGHT. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 ROBIN & CHRISTIAN BACHELET PHONE: 970-566-2586 EMAIL: RBACHELET@MAC.COM VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: KENT McDERMOTT EMAIL: KENT.McDERMOTT@VERIZONWIRELESS.COM AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2018 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2015) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: GENERAL NOTES GN-1 LEGEND W W W W W SS SS SS SS SS SS F F F F F F GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS OE OE OE OE OE UT UT UT UT UT X X X X X SS SS S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD SD SD SD SD SD SD SD SD E E E E E E UE UE UE UE UE UE OT OT OT OT OT OT EV D O O O O O O O U/G U/G U/G U/G U/G OHW OHW OHW OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER GENERAL NOTES (CONTINUED) GN-2 3 DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 3-4 5-9 10-14 15-19 OVER 19 1 2 5 10 12 15 STREET TREE NOTES: 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. 3. STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE. PHOTOSIMULATION VIEWS PH-1 4 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING SOUTHEAST) 1 N.T.S. PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTHEAST) N.T.S. DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs POINT OF EMERGENCY ACCESS PHOTOSIMULATION VIEWS (CONTINUED) PH-2 5 2 PH-2 PHOTOSIMULATION VIEW (AFTER, LOOKING NORTH) N.T.S. 1 PH-2 PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTH) N.T.S. DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs 808 W. PROSPECT RD E Y GM EM SB S ET D D W WM WV WV ICV ICV ICV ICV ICV ICV ICV ICV ICV ICV VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP 3'-0" 3'-0" 3'-0" 14'-6" 1'-1" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. SOUTH EQUIPMENT PLAN C-1 7 N SECTOR B VZW ANTENNA AZ= 170° 1 C-1 SOUTH EQUIPMENT PLAN SCALE: 3/8"=1'-0" PROPOSED SLEEEPERS (SEE SHEET C-8 FOR MORE DETAIL) PROPOSED 3' WIDE TRAFFIC PAD NOTE: 1. NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. 2. ALL CABLES ASSOCIATED WITH THE INSTALLATION OF WIRELESS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW USING THE MOST DISCREET CAMOUFLAGE TECHNIQUES POSSIBLE. PROPOSED HYBRID RUN FROM EQUIPMENT CABINETS TO ROOFTOP OVP'S PROPOSED OVP MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (PAINT TO MATCH, SECTOR B ONLY) (2) PROPOSED RRH(S) MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (PAINT TO MATCH, SECTOR B ONLY) PROPOSED VERIZON 8' ANTENNA MOUNTED TO FACADE OF EXISTING BUILDING (TYP OF 3) (SEE SHEET A-1 FOR MORE DETAIL) PROPOSED COAX RUN FROM RRH(S) TO ANTENNA(S) PROPOSED COAX CHASE FROM UPPER ROOF LEVEL TO MEZZANINE LEVEL (FULLY SCREEN ALL CABLES) DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SB GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP E E E E E E F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F 10'-0" 1'-3" 10" 10'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 C-2 WEST SIDE EQUIPMENT PLAN SCALE: 1/4"=1'-0" WEST EQUIPMENT PLAN C-2 8 N A SECTOR CABLE TABLE 350° AZIMUTH LENGTH 1 NO. TYPE NOTES: F F F F F F F F F F E E E E E E E 39'-5" 44'-8" 34'-8" 47'-0" F F F F F F F F F F E E E E E E E 34'-8" 47'-0" 2 C-3 PROPOSED NORTH ELEVATION SCALE: 1/8"=1'-0" 1 C-3 EXISTING NORTH ELEVATION SCALE: 1/8"=1'-0" NORTH ELEVATIONS C-3 9 PROPOSED VERIZON RAD CENTER 39'-5" AGL TOP OF PROPOSED PENTHOUSE 44'-8" AGL GRADE 0'-0" AGL PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 6) (SEE SHEET A-1 FOR MORE DETAIL) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 2) (SEE DETAIL 6/C-8) PROPOSED ANTENNA PENTHOUSE (SEE SHEET C-6 FOR MORE DETAIL) (2) PROPOSED RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP) DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 37'-0" 45'-2" 47'-0" 41'-0" 45'-2" 47'-0" 2 C-4 PROPOSED SOUTH ELEVATION SCALE: 1/8"=1'-0" 1 C-4 EXISTING SOUTH ELEVATION SCALE: 1/8"=1'-0" SOUTH ELEVATIONS C-4 10 TOP OF EXISTING STRUCTURE 47'-0" AGL GRADE 0'-0" AGL TOP OF PROPOSED ANTENNAS 41'-0" AGL PROPOSED OVP MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (PAINT TO MATCH, SECTOR B ONLY) (2) PROPOSED RRH(S) MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (PAINT TO MATCH, SECTOR B ONLY) PROPOSED VERIZON 8' ANTENNA MOUNTED TO FACADE OF EXISTING BUILDING (TYP OF 3) (SEE SHEET A-1 FOR MORE DETAIL) PROPOSED COAX CHASE FROM UPPER ROOF LEVEL TO MEZZANINE LEVEL DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. 39'-5" 47'-0" 44'-8" 47'-0" 2 C-5 PROPOSED WEST ELEVATION SCALE: 1/8"=1'-0" 1 C-5 EXISTING WEST ELEVATION SCALE: 1/8"=1'-0" WEST ELEVATIONS C-5 11 GRADE 0'-0" AGL DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs PROPOSED VERIZON RAD CENTER 39'-5" AGL TOP OF PROPOSED PENTHOUSE 44'-8" AGL PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 6) (SEE SHEET A-1 FOR MORE DETAIL) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 2) (SEE DETAIL 6/C-8) PROPOSED ANTENNA PENTHOUSE (SEE SHEET C-6 FOR MORE DETAIL) (2) PROPOSED RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 4) 12'-0" 10'-0" 12'-0" 10'-0" 1'-6" (TYP) 8'-11" (TYP) CONCEALMENT DETAILS C-6 12 PROPOSED ANTENNA WITHIN PENTHOUSE PROPOSED PENTHOUSE (PENTHOUSE TO MATCH EXISTING BUILDING SIDING) RF TRANSPARENT MATERIAL SPECIFICATIONS FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES: 1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES. 2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING. 3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL. 4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPE. 5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION. 6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN DRAWINGS. 7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS FOLLOWS: 1/2" DIAMETER NUTS 8 FT-LBS TORQUE 5/8" DIAMETER NUTS 16 FT-LBS TORQUE 3/4" DIAMETER NUTS 24 FT-LBS TORQUE FIBERGLASS PANEL NOTES: - FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN. - PANELS TO BE MINIMUM 1/4" THICKNESS. 1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF TRANSPARENT MATERIALS. 2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED APPEARANCE. 3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT. 4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT. 5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS: STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS. 6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE ULTRAVIOLET PROTECTION. 7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN. 8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS. PROPOSED RRH WITHIN PENTHOUSE PROPOSED OVP WITHIN PENTHOUSE 1 C-6 PENTHOUSE CONCEALMENT DETAILS SCALE: 1/2"=1'-0" NOTE: PROPOSED FRAMING AND ATTACHMENT DETAILS NOT SHOWN FOR CLARITY. 3'-0" 6'-0" 2" 2'-10" 3'-0" 2'-10" FRONT VIEW LEFT SIDE VIEW TOP VIEW FRONT VIEW LEFT SIDE VIEW TOP VIEW 6'-0" 2" 2'-6" 2'-10" 2'-6" 2'-10" 2'-0" 5" 1'-1" 6'-8" 6" 4'-8" 5'-8" 7'-8" 6'-8" 6" 4'-2" DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 1 C-7 RBA72 CABINET DETAIL SCALE: 3/4"=1'-0" 4" 2'-6" 1'-6" 6" MIN. (TYP) 4" MIN. TO SECONDARY ELECTRIC 12" MIN. TO PRIMARY ELECTRIC NOTES: 1. CONTRACTOR TO ORDER HANDHOLE BOX WITH THE CORRECT NUMBER AND SIZE OF KNOCKOUTS NEEDED. 2. VERIFY DIMENSIONS OF UNIT. 24" 26" 30" BOX COVER 37 5/8" 35 3/8" 6" MIN. 8" (V.I.F.) 3M FIRESTOP SEALANT CP25WB + CAULK OR EQUAL 1" THICK MINIMUM, APPLY FLUSH WITH WALL (BOTH SIDES) APPROVED FIRE SAFE INSULATION, TIGHTLY PACKED (PRE-MOLDED CALCIUM SILICATE OR ROCK WOOL) STEEL SLEEVE GROUTED SOLID IN CORE, FLUSH WITH WALL (1" OR GREATER DIAMETER THAN CONDUIT) NEW EMT CONDUIT (TYP FOR ELECTRIC) EXISTING CONCRETE WALL CORE DRILL OPENINGS THROUGH MASONRY WALL. DIAMETER TO BE VERIFIED IN FIELD. DO NOT CUT THRU STEEL REINFORCING. DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 F F F F F F F F F F F F F F F F F F F F F F F F F F F 6" MIN. E E E E E E E E E E E E E E E DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs POWER & FIBER ROUTING DETAILS C-9 15 PROPOSED CONCEALMENT CHASE FOR FIBER ROUTING UP SIDE OF BUILDING (MATCH EXISTING DOWNSPOUT) EXISTING BUILDING PROPOSED FIBER IN 2" EMT CONDUIT FROM BASE OF BUILDING TO EQUIPMENT CABINET PROPOSED FIBER IN 2" PVC CONDUIT FROM VAULT TO BASE OF BUILDING 2 C-9 PROPOSED FIBER ROUTING ELEVATION SCALE: N.T.S. NOTE: 1. ALL SUPPORT/ANCHOR HARDWARE TO BE HOT DIPPED GALVANIZED OR STAINLESS STEEL. 2. VERIFY PLACEMENT DOES NOT BLOCK EXISTING WINDOWS ON BUILDING. 3 C-9 POWER CONDUIT DETAIL N.T.S. F F F F F F F F F F F 12'-0" 12'-0" 2'-4" (TYP) 2'-4" (TYP) 1'-6" (TYP) 3'-0" (TYP) DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs SCREEN DETAILS C-10 16 1 C-10 ANTENNA SCREEN - SECTOR A & C N.T.S. PROPOSED ANTENNA CONCEALMENT WALL (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) (FINAL DESIGN TBD) PROPOSED OVP MOUNTED TO CUSTOM MOUNT (TYP) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM MOUNT (TYP OF 6) PROPOSED VERIZON RRH MOUNTED TO CUSTOM MOUNT (TYP OF 4) 2 C-10 ANTENNA SCREEN - SECTOR B N.T.S. F F F F F F F F F F F F F F F DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs ANTENNA PLAN A-1 17 A-1 350° 39'-5" TBD 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS - - HYBRID 6x12 90 FT. A-2 A-3 B-1 B-2 B-3 G-1 G-2 G-3 ANTENNA & CABLE SCHEDULE SECTOR AZIMUTH MOUNTING HEIGHT ANTENNA MODEL TECHNOLOGY ANTENNA SPECIFICATIONS MECHANICAL DOWNTILT ELECTRICAL DOWNTILT CABLE SIZE CABLE LENGTH GAMMA BETA ALPHA COMMSCOPE NHH-45C-R2B (SHARED HYBRID) - 16.5" 29.5" 12.6" DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs OVP & MOUNTING DETAILS A-2 18 FRONT VIEW SIDE VIEW NOTE: FOR HYBRID CABLE RUNS OVER 262', THE CONTRACTOR IS TO ADD BRIDGE KIT MODEL# RM-3315-WB-KIT & 3315-WB-KIT. MOUNTING BRACKET 1 A-2 OVP DETAIL N.T.S. BOTTOM VIEW DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs M LOAD CENTER PROPOSED 200A LOAD CENTER EXISTING 120/208 V 3Ø 500kVA TRANSFORMER (FAULT = TBD) PROPOSED 3" PVC CONDUIT WITH (4) 3/0 CU CONDUCTORS (LENGTH = ±80'-0") PROPOSED 200A METER MAIN PROPOSED (4) 3/0 CU CONDUCTORS & (1) #6 CU GROUND IN TBD EMT CONDUIT (LENGTH = ±200-0") 1 E-1 ONE-LINE DIAGRAM N.T.S 2 E-1 ILC PANEL SCHEDULE N.T.S ONE-LINE DIAGRAM & PANEL SCHEDULE E-1 19 GROUND ROD BLDG STEEL WATER ET E E E E E E E E E E E E E E E E E E E E E E E E E F F F F F F F F F F F F F F F F F F E SS SS SS SS SS SS SS SS SS SS E E E E E E E E E E E E E E E SD SD SD SD SD SD SD SD SD SD SD SD SD DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs 1 U-1 UTILITY PLAN SCALE: 1/16"=1'-0" UTILITY PLAN U-1 20 1/16 inch = 1 ft. ( IN FEET ) F F F F F F F F F F F E E E E E E F F F F F F F F DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs N 1 G-1 GROUNDING PLAN SCALE: 1/2"=1'-0" 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) GROUNDING PLAN G-1 21 GROUND ROD W/ ACCESS XIT GROUND ROD 5/8" GALVANIZED GROUND ROD MECHANICAL TYPE CONNECTION CADWELD TYPE CONNECTION GROUND SYMBOLS: GROUNDING WIRE PROPOSED CADWELD (TYP) PROPOSED BATTERY CABINET PROPOSED MASTER GROUND BAR TYPE NC TYPE GT TYPE GL LUG TYPE HA TYPE GR TYPE VS TYPE HS TYPE SS TYPE XA TYPE PT (2) (3) (5) (4) (1) MGB 2 EM SGC424-VZW OR EQUAL GALVANIZED STEEL GROUND BAR, BY ELECTRIC MOTION COMPANY (SEE SCHEDULE BELOW). INSULATORS, BY HARGER CAT. #5263-A5. 5/8 " LOCKWASHERS, STAINLESS STEEL. WALL MOUNTING BRACKET, HARGER CAT. #WBKT-2. 5/8-11x3" H.H.C.S. BOLTS, STAINLESS STEEL. (2) (3) (4) (5) (1) LEGEND OR EQUAL REMARKS EM SGC412-VZW CAT. NO. ELECTRIC MOTION COMPANY MANUFACTURER CGB 3 TYPE QTY. GROUND BAR SCHEDULE ELECTRIC MOTION COMPANY "GALV STEEL" STEEL STAMPED ON EITHER END CADWELD AT TWO LOCATIONS 3'-6" FINISHED GRADE 1'-0" 36" THREADED PVC PIPE CAP 2" SLOTTED HOLE (TYP) 5/8"X10'-0" GALVANIZED GROUND ROD.TOTAL DEPTH IN SOIL TO BE 8'-0" MIN. EXOTHERMIC CAD WELD (2) #2 AWG BARE SOLID GROUND WIRE 6" Ø PVC PIPE DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 SB ICV VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP SB ICV VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 L-1 LANDSCAPING PLAN - EXISTING SCALE: 1"=10'-0" S ET D VP VP VP D S ET D VP VP VP D THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 L-2 LANDSCAPING PLAN - EXISTING SCALE: 1"=10'-0" LANDSCAPING PLAN (CONTINUED) L-2 24 2 L-2 LANDSCAPING PLAN - PROPOSED SCALE: 1"=10'-0" EXISTING WALKWAY NOTE: 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. ALL EXISTING TREES TO REMAIN AND BE PROTECTED. DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED UNDERGROUND POWER ROUTE TO EXTERIOR OF BUILDING IN 3" CONDUIT (LENGTH = 80'-0") EXISTING 500kVA, 120/208V, 3ɸ TRANSFORMER PROVIDED BY FTC L&P PROPOSED 5'-0" WIDE UTILITY EASEMENT - PROPERTY OWNER TO VERIZON EXISTING TREE EXISTING BUILDING EXISTING BUILDING EXISTING PARKING LOT EXISTING PARKING LOT EXISTING TREE EXISTING WALKWAY LANDSCAPING PLAN L-1 23 ANY DISTURBED ORNAMENTAL GRASS, IRRIGATION, AND LANDSCAPE ROCK TO BE REPLACED AFTER CONSTRUCTION 2 L-1 LANDSCAPING PLAN - PROPOSED SCALE: 1"=10'-0" EXISTING ORNIMENTAL GRASS (TYP) EXISTING WALKWAY EXISTING BUILDING EXISTING SIDEWALK EXISTING ORNIMENTAL GRASS (TYP) EXISTING WALKWAY EXISTING SIDEWALK EXISTING ORNAMENTAL GRASS TO BE REMOVED AND REPLACED FOR FIBER CONDUIT INSTALLATION (TYP) EXISTING BUILDING NOTE: 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. ALL EXISTING TREES TO REMAIN AND BE PROTECTED. DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs UNDERGROUND MEET POINT TO BE COORDINATED WITH FIBER PROVIDER 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING ORNAMENTAL GRASS TO BE RELOCATED TO THE SOUTH FOR FIBER BOX INSTALLATION N APPROXIMATE LOCATION FOR RELOCATED ORNAMENTAL GRASS ANY DISTURBED ORNAMENTAL GRASS, IRRIGATION, AND LANDSCAPE ROCK TO BE REPLACED AFTER CONSTRUCTION JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs CABLE TO ANTENNA CABLE GROUNDING CLAMP KIT #6 AWG GREEN INSULATED COPPER GROUNDING CONDUCTOR CABLE TO EQUIPMENT 3M SCOTCH SUPER 33+ VINYL ELECTRICAL TAPE (OR APPROVED EQUAL) PROPOSED COAX VAPOR WRAP SEALANT COAX TO JUMPER CONNECTION PROPOSED JUMPER 2 G-2 TYPICAL CABLE GROUNDING SCALE: N.T.S. 4 G-2 WEATHERPROOFING DETAIL SCALE: N.T.S. 5 G-2 TYPICAL CADWELD TYPE CONNECTIONS SCALE: N.T.S. 6 G-2 GROUND BAR DETAIL SCALE: N.T.S. EACH ANTENNA SECTOR (TYP) COAX TYP. #6 THWN GREEN INSULATED (TYP) SECTOR AGB #2 AWG SOLID BTCW #2 AWG SOLID BTCW #2 AWG SOLID BTCW HYBRIFLEX AND COAX GROUND KIT #6 THWN GREEN INSULATED MGB AT EQUIPMENT PLATFORM (2) #2 AWG SOLID BTCW EXISTING GROUND ROD AT GRADE ANTENNA RRH MOUNTING ANTENNA MOUNTING MOUNTING ANTENNA MOUNTING OVP RRH RRH 3 G-2 GROUND ROD DETAIL SCALE: N.T.S. 1 G-2 GROUNDING RISER DIAGRAM SCALE: N.T.S. GROUNDING DETAILS G-2 22 RRH ANTENNA PROPOSED EQUIPMENT CABINET PROPOSED (2)-#2 BARE TINNED SOLID COPPER GROUND WIRE ROUTED DOWN TO PROPOSED GROUND ROD AT GRADE PROPOSED 5/8"Øx10'-0" GROUND ROD BURIED 36" BELOW GRADE (SEE DETAIL 3/G-2) PROPOSED GROUND WIRE FROM EQUIPMENT CABINET TO MASTER GROUND BAR (TYP) PROPOSED (2)-#2 GREEN THHN GROUND WIRE TO MASTER GROUND BAR AT EQUIPMENT PLATFORM (TYP PER SECTOR) PROPOSED SECTOR GROUND BAR (TYP) PROPOSED #6 AWG GROUND WIRE TO OVP (TYP) PROPOSED #6 AWG GROUND WIRE TO RRH'S (TYP) PROPOSED #6 AWG GROUND WIRE TO ANTENNA (TYP) PROPOSED VERIZON ANTENNA MOUNTED BEHIND SCREEN WALL (TYP OF 3) PROPOSED VERIZON ENCLOSURE PROPOSED (2)-#2 GREEN THHN GROUND WIRE TO MASTER GROUND BAR AT EQUIPMENT PLATFORM PROPOSED VERIZON RRH MOUNTED TO BACKSIDE OF PARAPET WALL (TYP OF 2) PROPOSED VERIZON OVP MOUNTED TO BACKSIDE OF PARAPET WALL PROPOSED VERIZON RRH MOUNTED TO CUSTOM MOUNT BEHIND SCREEN WALL (TYP OF 4) PROPOSED VERIZON OVP MOUNTED TO CUSTOM MOUNT BEHIND SCREEN WALL (TYP OF 2) NOTE: 1. ALL CABLES ASSOCIATED WITH THEINSTALLATION OF WIRELESS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW USING THE MOST DISCREET CAMOUFLAGE TECHNIQUES POSSIBLE. PROPOSED 200A,3ɸ NEMA 3R DISCONNECT (MOUNTED TO WALL BELOW METER) PROPOSED 200A METER MAIN MOUNTED TO WALL GRAPHIC SCALE 16 0 8 16 32 64 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING BUILDING UTILITY PLAN SCHEDULE QUANTITY 1 POWER NOTES: 1. SERVICE SHALL BE 120/208V, 3ɸ, 3W, 200A 2. CONTRACTOR TO COORDINATE INSPECTION AND PLACEMENT OF METER WITH THE LOCAL UTILITY COMPANY: FTC L&P CONTACT: PHONE: W.O. NUMBER: TBD ITEM LENGTH PROVIDED BY INSTALLED BY TRANSFORMER - FTC L&P FTC L&P DESCRIPTION EXISTING 120/208V, 3ɸ, 3W, 500kVA 1 CONDUITS - LINE TO METER 3" PVC 80'± CONTRACTOR 3 CONDUCTORS - LINE TO METER (4) - 3/0 CU CONDUCTORS 85'± CONTRACTOR CONTRACTOR CONTRACTOR 1 METER SOCKET TYP - CONTRACTOR CONTRACTOR 1 METER TYP - FTC L&P FTC L&P PROPOSED (4) - 3/0 AWG CU CONDUCTORS IN 3" CONDUIT (LENGTH = 80'-0") PROPOSED 200A METER MAIN FAULT: X,XXXA (L-L) POWER FROM EXISTING 500kVA, 120/208V, 3ɸ TRANSFORMER PROVIDED BY FTC L&P PROPOSED 200A, 3ɸ, NEMA 3R DISCONNECT FAULT: X,XXXA (L-L) 2 200A, 3ɸ DISCONNECT TYP - CONTRACTOR CONTRACTOR PROPOSED ELECTRICAL RUN ACROSS BUILDING ROOFTOP FROM DISCONNECT TO EQUIPMENT CABINET (LENGTH = 270'-0") Know what's below. Call before you dig. POTHOLE TO VERIFY STORM & SEWER LOCATIONS & DEPTH PRIOR TO CONSTRUCTION PROPOSED ROOF PENETRATION (SEE DETAIL 6/C-8) PROPOSED WALL PENETRATION (SEE DETAIL 7/C-8) MAIN PROPOSED #6 CU SERVICE ENTRY GROUND PROPOSED 200A METER DISCONNECT PANEL CIRCUIT AND LOAD SCHEDULE LOAD LOAD PER PHASE (VA) PHASE A B C DESCRIPTION QTY. UNIT V.A. LOADS CONTINUOUS LOADS N0N-CONTINUOUS TRIP POLES WIRE SIZE A.I.C. 10,000 THHN WIRE TYPE - - 10,000 THHN 10,000 THHN 10,000 THHN SUBTOTAL CONTINUOUS 4222 - - - VOLTAGE: 120/208 CYCLE: 60 PHASE: 3 WIRE: 4 NEUTRAL: 200 AMPS MAIN BREAKER: 200 AMP FRAME MAIN LUGS: AMPS MAINS: TOP BOTTOM A.I.C.: 22000 TRIP: 200 AMPS MAIN COPPER BUS: 200 AMPS X SERVICE: DESIGNATION: LOCATION: LOAD PER PHASE (VA) LOAD PHASE A B C DESCRIPTION QTY. UNIT V.A. LOADS CONTINUOUS LOADS N0N-CONTINUOUS TRIP POLES WIRE SIZE A.I.C. THHN 10,000 WIRE TYPE - - SUBTOTAL CONTINUOUS 9580 8180 TOTAL 5200 9422 120/208 VAC N/A N/A NO EQUAL: APPROVED EQUAL: MOUNTING: SURFACE: X FLUSH: TOTAL KVA CONTINUOUS x 1.25 TOTAL KVA NON-CONTINUOUS TOTAL KVA TOTAL AMPS BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU 200A S G S N #4 TEMP. BOND #TBD #TBD 120/208 VAC 3Ø 200 AMP SERVICE SUPPLIED & INSTALLED BY SITE ELECTRICAL CONTRACTOR 4380 2980 X 1400 1400 1400 HVAC #1 RECTIFIER #5 RECTIFIER #6 RECTIFIER #7 RECTIFIER #8 SPARE SPARE SPARE HVAC #2 1400 1 1400 1400 1400 - - - - - - 1 1 1 1 1 1400 1400 1400 1400 1000 1000 1000 1000 1400 1400 1400 1400 1400 1000 1000 1000 1000 1400 1400 1 1 1 RECTIFIER #1 1400 1400 RECTIFIER #2 RECTIFIER #3 1400 1400 RECTIFIER #4 - 1 1400 1400 GFCI RECEPTACLES SPARE - 180 SPARE TELCO BOX RECEP. LIGHT SPARE SPARE - 180 22 - - 1 1 1 1400 1400 1400 1400 1400 1400 1400 1400 180 180 22 - - - - - - - - - - - - - - - - - 5200 5200 33.98 0 33.98 94.2 X 30A 2 10 X X 30A 2 10 10,000 THHN X 30A 2 10 10,000 THHN X 30A 2 10 10,000 THHN - - - - - - X X X - - - - 10 2 30A THHN 10,000 10 2 30A X THHN 10,000 10 2 30A X THHN 10,000 10 2 30A X THHN 10,000 12 2 20A X THHN 10,000 12 2 20A X 20A 1 12 20A 1 12 20A 1 12 TBD - - TBD - - (SHARED HYBRID) - 170° TBD - - HYBRID 6x12 80 FT. (SHARED HYBRID) - TBD - - TBD - - (SHARED HYBRID) - 230° TBD - - (SHARED HYBRID) - TBD - - TBD - - (SHARED HYBRID) - HYBRID 6x12 90 FT. 37'-0" 1 A-1 ANTENNA PLAN SCALE: 1/2"=1'-0" 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED VERIZON OVP MOUNTED TO CUSTOM MOUNT BEHIND SCREEN WALL (TYP OF 1 PER SECTOR, 4 TOTAL) N PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM MOUNT BEHIND SCREEN WALL (TYP OF 6) SECTOR A VZW ANTENNA AZ= 350° SECTOR B VZW ANTENNA AZ= 170° SECTOR C VZW ANTENNA AZ= 230° 350° 350° COMMSCOPE NHH-45C-R2B COMMSCOPE NHH-45C-R2B 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS 39'-5" 39'-5" 39'-5" 170° 170° 37'-0" 37'-0" COMMSCOPE NHH-45C-R2B COMMSCOPE NHH-45C-R2B COMMSCOPE NHH-45C-R2B 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS COMMSCOPE NHH-45C-R2B COMMSCOPE NHH-45C-R2B COMMSCOPE NHH-45C-R2B 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS 95.9"(L) x 18.0"(W) x 7.0"(D) 87.1 LBS 230° 39'-5" 230° 39'-5" (2) PROPOSED RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP PER SECTOR) PROPOSED CUSTOM MOUNT BEHIND PENTHOUSE (FINAL DESIGN TBD) PROPOSED CUSTOM CONCEALMENT (FINAL DESIGN TBD) PROPOSED ANTENNA CONCEALMENT (CONCEALMENT TO MATCH EXISTING BUILDING STUCCO) PROPOSED PENTHOUSE (PENTHOUSE TO MATCH EXISTING BUILDING SIDING) PROPOSED VERIZON ANTENNA MOUNTED TO EXTERIOR WALL BEHIND CONCEALMENT (TYP OF 3) NOTE: 1. ALL CABLES ASSOCIATED WITH THE INSTALLATION OF WIRELESS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW USING THE MOST DISCREET CAMOUFLAGE TECHNIQUES POSSIBLE. PROPOSED OVP MOUNTED TO PARAPET WALL PROPOSED VERIZON RRH MOUNTED TO PARAPET WALL (TYP OF 2) PROPOSED VERIZON ANTENNA MOUNTED TO BACK OF PARAPET WALL (TYP OF 3) NOTE: 1. ALL CABLES ASSOCIATED WITH THE INSTALLATION OF WIRELESS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW USING THE MOST DISCREET CAMOUFLAGE TECHNIQUES POSSIBLE. ANCHOR TO WALL WITH (2) HILTI 3/8"X3-1/2" (EMBEDMENT) HIT THREADED ROD WITH HIT HY-150 INJECTION ADHESIVE EMT CONDUIT FOR POWER CONDUIT CLAMP P1000 UNISTRUT (6'-0" O.C.) PROPOSED 200A METER MAIN MOUNTED TO EXTERIOR WALL PROPOSED 200A METER DISCONNECT MOUNTED TO EXTERIOR WALL PROPOSED POWER IN 2" PVC CONDUIT ROUTED UP THROUGH STAIRWELL FROM METER MAIN TO EQUIPMENT CABINET (SEE DETAIL 3/C-9) PROPOSED POWER IN 3" EMT CONDUIT FROM XFMR TO DISCONNECT 1 C-9 PROPOSED POWER ROUTING ELEVATION SCALE: N.T.S. PROPOSED ROOF PENETRATION (SEE DETAIL 6/C-8) PROPOSED WALL PENETRATION (SEE DETAIL 7/C-8) EXISTING WALL MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs CONSTRUCTION DETAILS (CONTINUED) C-8 14 NOTES: 1. FOR EMT CONDUIT, MAX PROPOSED SPACING BETWEEN SLEEPERS IS 10' O.C. 2. FOR COAX, MAX PROPOSED SPACING BETWEEN SLEEPERS IS 3' O.C. PROPOSED 4" CONDUIT CLAMP PROPOSED 4" EMT CONDUIT FOR HYBRIFLEX CABLE PROPOSED COOPER DURA BLOK DB10-36 ROOFTOP SUPPORT 2 C-8 HYBRIFLEX CONDUIT DETAIL N.T.S. 3 C-8 FIBER & POWER CONDUIT DETAIL N.T.S. NOTES: 1. FOR EMT CONDUIT, MAX PROPOSED SPACING BETWEEN SLEEPERS IS 10' O.C. 2. FOR COAX, MAX PROPOSED SPACING BETWEEN SLEEPERS IS 3' O.C. PROPOSED COOPER DURA BLOK DB10 ROOFTOP SUPPORT PROPOSED 2" CONDUIT FOR FIBER PROPOSED 2" CONDUIT CLAMP PROPOSED 2" CONDUIT FOR POWER PROPOSED 2" CONDUIT CLAMP NOTE: SEPARATION DIMENSIONS TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS. 4 C-8 UTILITY TRENCH DETAIL N.T.S. 5 C-8 PULLBOX DETAIL N.T.S. FINISHED GRADE OR PAVING. MATCH SLOPE AND THICKNESS OF EXISTING CONDITIONS 3"Ø SCH 40 PVC POWER CONDUIT (AS REQUIRED) BACKFILL (SAND OR NATIVE SOIL) PER ASTM STANDARDS UNDISTURBED SOIL UTILITY WARNING TAPE 2"Ø SCH 40 PVC FIBER CONDUIT (AS REQUIRED) 0.5 CDF SKID RESISTANT SURFACE 5/8"x4" PULL SLOT MAKE: HUBBELL 24"X36" FRP STRAIGHT WALL MODEL: B16243630A LIFTING INSERTS (4) NOTE: 1. ALL SUPPORT/ANCHOR HARDWARE TO BE HOT DIPPED GALVANIZED OR STAINLESS STEEL. 2. VERIFY PLACEMENT DOES NOT BLOCK EXISTING WINDOWS ON BUILDING. 1 C-8 FIBER CONDUIT DETAIL N.T.S. ANCHOR TO WALL WITH (2) HILTI 3/8"X3-1/2" (EMBEDMENT) HIT THREADED ROD WITH HIT HY-150 INJECTION ADHESIVE PROPOSED CHASE CONCEALMENT (TO MATCH EXISTING DOWNSPOUT) EMT CONDUIT FOR FIBER CONDUIT CLAMP P1000 UNISTRUT (6'-0" O.C.) 6 C-8 ROOF PENETRATION DETAIL N.T.S. 7 C-8 WALL PENETRATION DETAIL N.T.S. 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 C-7 RBA72 BATTERY CABINET DETAIL SCALE: 3/4"=1'-0" 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 3 C-7 CABINET PLINTH DETAIL SCALE: 3/4"=1'-0" 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) CONSTRUCTION DETAILS C-7 13 NOTE: 1. VERIFY INTEGRITY OF EXISTING ROOF MEMBRANE PRIOR TO PLACING PROPOSED EQUIPMENT NOTE: DEKA FAHRENHEIT HT200ET BATTERY (OR APPROVED EQUAL) WEIGHT: 151 LBS 4 C-7 BATTERY DETAIL N.T.S. NOTE: MAXIMUM (240) DEKA FAHRENHEIT HT200ET BATTERIES TO BE INSTALLED (UP TO 62.16 GALLONS OF ELECTROLYTE) (2) PROPOSED 1/2" THICK RUBBER MATS BENEATH STEEL PLINTH TO PROTECT ROOF SURFACE (CUT TO MATCH DIMENSION OF PLATE) DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 C-6 SECTOR B CONCEALMENT DETAILS SCALE: 1/2"=1'-0" PROPOSED ANTENNA WITHIN CONCEALMENT PROPOSED ANTENNA CONCEALMENT (CONCEALMENT TO MATCH EXISTING BUILDING STUCCO) 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) NOTE: 1. ALL CABLES ASSOCIATED WITH THE INSTALLATION OF WIRELESS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW USING THE MOST DISCREET CAMOUFLAGE TECHNIQUES POSSIBLE. TOP OF STRUCTURE 47'-0" AGL GRADE 0'-0" AGL TOP OF STRUCTURE 47'-0" AGL 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs TOP OF EXISTING STRUCTURE 45'-2" AGL PROPOSED VERIZON RAD CL 37'-0" AGL TOP OF EXISTING STRUCTURE 47'-0" AGL GRADE 0'-0" AGL TOP OF EXISTING STRUCTURE 45'-2" AGL 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED ANTENNA CONCEALMENT (TYP OF 3 , PAINT TO MATCH) NOTE: 1. ALL CABLES ASSOCIATED WITH THE INSTALLATION OF WIRELESS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW USING THE MOST DISCREET CAMOUFLAGE TECHNIQUES POSSIBLE. PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs GRADE 0'-0" AGL TOP OF PARAPET 34'-8" AGL TOP OF STRUCTURE 47'-0" AGL TOP OF PARAPET 34'-8" AGL TOP OF STRUCTURE 47'-0" AGL 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED 200A METER MAIN MOUNTED TO EXTERIOR WALL PROPOSED 200A METER DISCONNECT MOUNTED TO EXTERIOR WALL PROPOSED POWER IN 2" PVC CONDUIT ROUTED UP THROUGH STAIRWELL FROM METER MAIN TO EQUIPMENT CABINET (SEE DETAIL 3/C-9) 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 6x12 HYBRIFLEX B 170° C 230° COAX HYBRIFLEX 1/2" 6x12 1 1 90' SECTOR A VZW ANTENNA AZ= 350° SECTOR C VZW ANTENNA AZ= 230° PROPOSED SLEEPERS (TYP) (SEE SHEET C-8 FOR MORE DETAIL) (2) PROPOSED HYBRID CABLES FROM EQUIPMENT CABINET TO ROOFTOP OVP'S (SEE SHEET C-8 FOR MORE DETAIL) PROPOSED 10'X10' LEASE AREA BY VERIZON PROPOSED EQUIPMENT CABINET (TYP OF 2) (SEE SHEET C-7 FOR MORE DETAIL) PROPOSED TRAFFIC PAD (TYP) PROPOSED FIBER IN CONDUIT ACROSS ROOF TO CABLE TRAY PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 6, SECTOR A & C ONLY) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP) (2) PROPOSED RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 4) EXISTING ACCESS HATCH PROPOSED ANTENNA PENTHOUSE (SEE SHEET C-6 FOR MORE DETAIL) 50' 90' PROPOSED ACCESS HATCH (FINAL DESIGN TBD) B 170° 80' 1 6x12 HYBRIFLEX DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs 1/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 4 0 2 4 8 16 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED POWER IN 2" EMT CONDUIT FROM BASE OF BUILDING TO EQUIPMENT CABINET NOTE: 1. ALL CABLES ASSOCIATED WITH THE INSTALLATION OF WIRELESS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW USING THE MOST DISCREET CAMOUFLAGE TECHNIQUES POSSIBLE. SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 6 8 10 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED ANTENNA CONCEALMENT (TYP) (PAINT TO MATCH) VP VP VP VP VP D THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 Z-1 SITE PLAN SCALE: 1"=20'-0" SITE PLAN Z-1 6 PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 3 PER SECTOR, SECTOR A & C ONLY) PROPOSED ANTENNA PENTHOUSE SHROUD (SEE SHEET C-6 FOR MORE DETAIL) PROPOSED OVP (TYP OF 1 PER SECTOR) PROPOSED 10'X10' LEASE AREA BY VERIZON PROPOSED EQUIPMENT CABINET (TYP OF 2) (SEE SHEET C-7 FOR MORE DETAIL) PROPOSED FIBER VAULT (SEE DETAIL 5/C-8) 10' UTILITY AND ACCESS EASEMENT - PROPERTY OWNER TO VERIZON" PROPOSED FIBER RUN (UNDERGROUND TO SIDE OF BUILDING) 2 PH-2 2 PH-1 (2) PROPOSED, (2) FUTURE RRH(S) (TYP PER SECTOR) 5' UTILITY EASEMENT - PROPERTY OWNER TO VERIZON" EXISTING 30'-0" WIDE EMERGENCY ACCESS, PUBLIC ACCESS, UTILITY AND DRAINAGE EASEMENT. RECEPTION # 20160069113 EXISTING 8'-0" WIDE UTILITY AND DRAINAGE EASEMENT. RECEPTION # 20160069113 EXISTING PUBLIC ACCESS EASEMENT. RECEPTION # 20160069113 EXISTING 15'-0" WIDE UTILITY AND DRAINAGE EASEMENT. RECEPTION # 20160069113 EXISTING 5'-0" WIDE NON-VEHICULAR PUBLIC ACCESS EASEMENT. RECEPTION # 20160069113 EXISTING 5'-0" WIDE UTILITY AND DRAINAGE EASEMENT. RECEPTION # 20160069113 EXISTING STORM DRAIN PIPE (TYP) EXISTING GAS LINE (TYP) DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs EXISTING ROOFTOP ACCESS HATCH EMERGENCY POINT OF EXIT EXISTING ADDRESS MOUNTED TO WALL 2 C-3 2 C-5 2 C-4 1 inch = 20ft. ( IN FEET ) GRAPHIC SCALE 20 0 10 20 40 80 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) NOTE: 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. ALL EXISTING TREES TO REMAIN AND BE PROTECTED. 3. ALL CABLES ASSOCIATED WITH THE INSTALLATION OF OF WIRELESS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW USING THE MOST DISCREET CAMOUFLAGE TECHNIQUES POSSIBLE. 4. UTILITIES REFRENCED FROM THE SLAB PROPERTY DRAWINGS BY NORTHERN ENGINEERING RECORDED ON 6-6-17. CONTRACTOR TO VERIFY PRIOR TO BEGINNING CONSTRUCTION. 5. SEWER MAIN REFRENCED FROM CITY OF FORT COLLINS STORMWATER ENGINEERING & DEVELOPMENT REVIEW DIVISION MAPPING SYSTEM. CONTRACTOR TO VERIFY PRIOR TO BEGINNING CONSTRUCTION. PROPOSED UNDERGROUND POWER RUN FROM EXISTING TRANSFORMER TO NEW ELECTRICAL METER MAIN ON SIDE OF BUILDING (SEE DETAIL 3/C-8) 5' UTILITY EASEMENT - PROPERTY OWNER TO VERIZON" PROPOSED ELECTRICAL RUN ACROSS BUILDING ROOFTOP FROM METER MAIN TO EQUIPMENT CABINET FIBER RUN TO BE PLACED 2' (MIN) FROM STORM LATERAL POTHOLE TO VERIFY STORM & SEWER LOCATIONS & DEPTH PRIOR TO CONSTRUCTION APPROXIMATE LOCATION OF STORM DRAIN (SEE NOTE 4/SHEET Z-1) APPROXIMATE LOCATION OF STORM DRAIN (SEE NOTE 4/SHEET Z-1) APPROXIMATE LOCATION OF WATER SERVICES (SEE NOTE 4/SHEET Z-1) POTHOLE TO VERIFY STORM LOCATION & DEPTH PRIOR TO CONSTRUCTION APPROXIMATE LOCATION OF STORM DRAIN (SEE NOTE 4) APPROXIMATE LOCATION OF SEWER MAIN (SEE NOTE 5/SHEET Z-1) STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR. 4. THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE. 5. SUBJECT TO APPROVAL BY THE CITY FORESTER - STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS. TREE PROTECTION NOTES: 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTRUBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUISNESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (1/2) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RAHTER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. GENERAL LANDSCAPE NOTES: 1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP EQUIVALENT. 2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. IRRIGATION SYSTEMS TO BE TURNED OVER TO THE CITY PARKS DEPARTMENT FOR MAINTENANCE MUST BE APPROVED BY THE PARKS MANAGER AND MEET PARKS IRRIGATION STANDARDS. DESIGN REVIEW SHALL OCCUR DURING UTILITIES DEPARTMENT IRRIGATION REVIEW PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AND CONSTRUCTION OBSERVATION AND INSPECTION BY PARKS SHALL BE INCORPORATED INTO THE CONSTRUCTION PROCESS. 3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING. 4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE TOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT (8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX (6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132. 5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE. 6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION. 7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. 8. THE FOLLOWING SEPERATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES: 40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS. 15 FEET BETWEEN ORNAMENTAL TREES AND STREET LIGHTS. 10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES. 6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES. 4 FEET BETWEEN SHRUBS AND PUBLIC WATER, AND SANITARY AND STORM SEWER LINES. 4 FEET BETWEEN TREES AND GAS LINES. 9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a). TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING SKYLIGHT HVAC UNIT AC SECURITY CAMERA VENT PIPE VP BOLLARD COMM DISH 2 GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 03/22/19. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. 18. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 19. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988) 20. THE PROPOSED DEVELEPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 21. THE PROPOSED DEVELEPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN SOUTH EQUIPMENT PLAN NORTH ELEVATIONS PROJECT DESCRIPTION 1. INSTALL (1) NEW ANTENNA PENTHOUSE & (3) ANTENNA CONCELAMENT SCREENS. 2. INSTALL (9) NEW 8' ANTENNAS AND (6) RRHS. 3. INSTALL CABLE TRAYS TO RUN HYBRIFLEX TO PROPOSED EQUIPMENT. 4. INSTALL (2) NEW EQUIPMENT CABINETS. 5. INSTALL (3) NEW OVPS. 6. INSTALL NEW FIBER VAULT AND RUN FIBER THROUGH EXTERIOR CONDUIT TO PROPOSED EQUIPMENT. 7. INSTALL NEW TRAFFIC MATS ON THE ROOF 8. RUN NEW POWER TO PROPOSED EQUIPMENT. 9. INSTALL NEW COAX CABLES. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: HIGH DENSITY MIXED-USE NEIGHBORHOOD DISTRICT APN: 9714321001 PARCEL SIZE: 62,564 S.F. ELEVATION: 5028.7' (NAVD 88) STRUCTURE TYPE: EXISTING STRUCTURE STRUCTURE HEIGHT: 47'-0"± AGL ANTENNA RAD CENTER: SECTOR A & C: 39'-5"± AGL SECTOR B: 37'-0"± AGL APPLICANT: VERIZON WIRELESS REAL ESTATE APPLICANT CONTACT: BRANDON KISER 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 PH: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 LEGAL DESCRIPTION LOT 1, THE SLAB PROPERTY, COUNTY OF LARIMER, STATE OF COLORADO PH-1 PHOTOSIMULATION VIEWS PH-2 PHOTOSIMULATION VIEWS (CONTINUED) C-2 WEST EQUIPMENT PLAN SOUTH ELEVATIONS WEST ELEVATIONS CONCEALMENT DETAILS PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION GN-1 GENERAL NOTES LANDSCAPING PLAN DRAWING SHEET: SITE INFORMATION: OF 24 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: 0 07-08-19 RPH 90% CDs REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 08-23-19 GAC REVISED 90% CDs GN-2 GENERAL NOTES (CONTINUED) UTILITY PLAN ONE-LINE DIAGRAM AND PANEL SCHEDULE LANDSCAPING PLAN (CONTINUED) C-1 C-3 C-4 C-5 C-6 C-7 CONSTRUCTION DETAILS L-1 L-2 G-1 G-2 GROUNDING PLAN GROUNDING DETAILS ANTENNA PLAN U-1 E-1 A-1 C-10 SCREEN DETAILS CONSTRUCTION DETAILS (CONTINUED) POWER & FIBER ROUTING DETAILS C-8 C-9 A-2 OVP & MOUNTING DETAILS