HomeMy WebLinkAboutSANCTUARY ON THE GREEN - PDP190003 - SUBMITTAL DOCUMENTS - ROUND 3 - PHOTOMETRIC PLANUP
UP
UP
UP
UP
C
B
B
B
A A
A
A
A
A
A
A
A
A
A
A A
A
A
A
A
A
B
B
A
1 SCALE:
SITE LIGHTING PHOTOMETRIC
1" = 50'-0"
PHOTOMETRY PLAN GENERAL NOTES:
1. VALUES SHOWN ARE MAINTAINED HORIZONTAL
ILLUMINANCE VALUES MEASURED AT GRADE.
2. SITE LIGHTING DESIGN HAS BEEN COMPLETED TO
PRODUCE EVEN ILLUMINATION OF PARKING AND
PAVED AREAS WITH MINIMAL GLARE ONTO
ADJACENT PROPERTIES.
3. ALL LIGHT FIXTURES SHALL BE FULLY SHIELDED
AND DIRECT LIGHT DOWNWARDS.
4. THERE WILL BE NO OFF-SITE GLARE ALLOWED.
5. PROVIDE HOUSE SIDE SHIELDS FOR ALL FULL
CUT-OFF LIGHT FIXTURES THAT ARE INSTALLED
WITHIN A DISTANCE OF 2.5 TIMES THE MOUNTING
HEIGHT OF THE PROPERTY LINE.
SITE LIGHTING DESIGN HAS BEEN COMPLETED TO
CONFORM TO CITY OF FORT COLLINS EXTERIOR
LIGHTING STANDARDS
SP
LUMINAIRE SCHEDULE
Symbol Label General Description Mounting Height Color Catalog Number Lamp LLF Watts SHIELDING
SITE POLE 1.00
PARKING & DRIVES
20'-0" AFG BLACK MCGRAW-EDISON
GLEON-AF-02-LED-
E1-SL3-BK-8030-DIM
LED 113W
SP
FULL CUT-OFF
WALL SCONCE 1.00
ENTRIES
7'-0" AFG BLACK SEAGULL LIGHTING
8537401-12
LED 13W
SW MAX
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW SW
SW
SW
SW
SW
SW
SW SW
SW
SW
SW SW SW SW SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW SW
SW
SW
SW
SW
SW
SW
SW
SW SW
SW
SW
SW SW
SW
SW
SW
SWSW
SW
SW
SW SW
SW
SW
SW
SW
SW
SW
SW
SW SW
SW SW
SW
SW
SW
SW
SW
SW
SW
SW SW
SP
SP
SP
SP SP
SP
SP
SW
FULL CUT-OFF
PROPOSED NATURAL HABITAT BUFFER ZONE
STUDIO LIGHTNING
63 SUNSET DR.
BAILEY, CO 80421
NOT FOR
CONSTRUCTION
FEBRUARY 13, 2019
DATE:
SHEET TITLE:
SANCTUARY ON THE GREEN
PROJECT DEVELOPMENT PLAN
FORT COLLINS, COLORADO
SOLITAIRE HOMES
BILL VEIO & DAVID PRETZLER
6645 E. HERITAGE PL. SOUTH
CENTENNIAL, CO 80111
303.721.9054
OWNER:
MAY 8, 2019
JULY 24, 2019
AUGUST 7, 2019
LP101
SITE LIGHTING
PHOTOMETRIC
AND LIGHTING
DETAILS