Loading...
HomeMy WebLinkAboutFTC RAMS CROSSING WTE VERIZON - BDR180027 - SUBMITTAL DOCUMENTS - ROUND 3 - PLANSFTC RAMS CROSSING 808 W PROSPECT RD FORT COLLINS, COLORADO 80525 NEW ROOFTOP MACRO ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS FROM SOUTH VAUGHN WAY MERGE ONTO 1-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W, KEEP RIGHT AT THE FORK TO CONTINUE ON I-270W, TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FT. COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W, TURN LEFT ONTO S COLLEGE AVE, TURN RIGHT ONTO W LAKE ST, TURN LEFT ONTO CENTRE AVE , TURN RIGHT ONTO W PROSPECT RD, SITE WILL BE ON YOUR RIGHT. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 ROBIN & CHRISTIAN BACHELET PHONE: 970-566-2586 EMAIL: RBACHELET@MAC.COM VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: KENT McDERMOTT EMAIL: KENT.McDERMOTT@VERIZONWIRELESS.COM AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2018 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2015) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: GENERAL NOTES GN-1 LEGEND W W W W W SS SS SS SS SS SS F F F F F F GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS OE OE OE OE OE UT UT UT UT UT X X X X X SS SS S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD SD SD SD SD SD SD SD SD E E E E E E UE UE UE UE UE UE OT OT OT OT OT OT EV D O O O O O O O U/G U/G U/G U/G U/G OHW OHW OHW OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER GENERAL NOTES (CONTINUED) GN-2 3 DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 3-4 5-9 10-14 15-19 OVER 19 1 2 5 10 12 15 STREET TREE NOTES: 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. PHOTOSIMULATION VIEWS PH-1 4 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING SOUTHEAST) 1 N.T.S. PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTHEAST) N.T.S. DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING POINT OF EMERGENCY ACCESS PHOTOSIMULATION VIEWS (CONTINUED) PH-2 5 2 PH-2 PHOTOSIMULATION VIEW (AFTER, LOOKING NORTH) N.T.S. 1 PH-2 PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTH) N.T.S. DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING 808 W. PROSPECT RD E Y GM EM SB S ET D D W WM WV WV ICV ICV ICV ICV ICV ICV ICV ICV ICV ICV VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP 3'-0" 3'-0" 3'-0" 14'-6" 1'-1" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. EQUIPMENT PLAN Z-2 7 N SECTOR B VZW ANTENNA AZ= 170° 1 Z-2 SOUTH EQUIPMENT PLAN SCALE: 3/8"=1'-0" PROPOSED CABLE TRAY PROPOSED TRAFFIC PAD NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. PROPOSED HYBRID RUN FROM EQUIPMENT CABINETS TO ROOFTOP OVP'S PROPOSED OVP MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (PAINT TO MATCH, SECTOR B ONLY) (2) PROPOSED RRH(S) MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (PAINT TO MATCH, SECTOR B ONLY) PROPOSED VERIZON 8' ANTENNA MOUNTED TO FACADE OF EXISTING BUILDING (TYP) PROPOSED COAX RUN FROM RRH(S) TO ANTENNA(S) PROPOSED COAX CHASE FROM UPPER ROOF LEVEL TO MEZZANINE LEVEL DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING SB GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP E E E E E E F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F 10'-0" 1'-3" 10" 10'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-3 WEST SIDE EQUIPMENT PLAN SCALE: 1/4"=1'-0" EQUIPMENT PLAN (CONTINUED) Z-3 8 N A SECTOR CABLE TABLE 350° AZIMUTH LENGTH 1 NO. TYPE NOTES: 39'-5" 44'-8" 34'-8" 47'-0" 34'-8" 47'-0" 2 Z-4 PROPOSED NORTH ELEVATION SCALE: 1/8"=1'-0" 1 Z-4 EXISTING NORTH ELEVATION SCALE: 1/8"=1'-0" ELEVATIONS Z-4 9 PROPOSED VERIZON RAD CENTER 39'-5" AGL TOP OF PROPOSED PENTHOUSE 44'-8" AGL GRADE 0'-0" AGL PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP) PROPOSED ANTENNA PENTHOUSE (SEE SHEET Z-7) (2) PROPOSED RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP) DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING 37'-0" 45'-2" 47'-0" 41'-0" 45'-2" 47'-0" 2 Z-5 PROPOSED SOUTH ELEVATION SCALE: 1/8"=1'-0" 1 Z-5 EXISTING SOUTH ELEVATION SCALE: 1/8"=1'-0" ELEVATIONS (CONTINUED) Z-5 10 TOP OF EXISTING STRUCTURE 47'-0" AGL GRADE 0'-0" AGL TOP OF PROPOSED ANTENNAS 41'-0" AGL PROPOSED OVP MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (PAINT TO MATCH, SECTOR B ONLY) (2) PROPOSED RRH(S) MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (PAINT TO MATCH, SECTOR B ONLY) PROPOSED VERIZON 8' ANTENNA MOUNTED TO FACADE OF EXISTING BUILDING (TYP) PROPOSED COAX CHASE FROM UPPER ROOF LEVEL TO MEZZANINE LEVEL DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 39'-5" 47'-0" 44'-8" 47'-0" 2 Z-6 PROPOSED WEST ELEVATION SCALE: 1/8"=1'-0" 1 Z-6 EXISTING WEST ELEVATION SCALE: 1/8"=1'-0" ELEVATIONS (CONTINUED) Z-6 11 GRADE 0'-0" AGL DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING PROPOSED VERIZON RAD CENTER 39'-5" AGL TOP OF PROPOSED PENTHOUSE 44'-8" AGL PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE PROPOSED ANTENNA PENTHOUSE (SEE SHEET Z-7) 12'-0" 10'-0" 12'-0" 10'-0" 1'-6" (TYP) 8'-11" (TYP) CONCEALMENT DETAILS Z-7 12 PROPOSED ANTENNA WITHIN PENTHOUSE PROPOSED PENTHOUSE (PENTHOUSE TO MATCH EXISTING BUILDING SIDING) RF TRANSPARENT MATERIAL SPECIFICATIONS FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES: 1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES. 2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING. 3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL. 4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPE. 5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION. 6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN DRAWINGS. 7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS FOLLOWS: 1/2" DIAMETER NUTS 8 FT-LBS TORQUE 5/8" DIAMETER NUTS 16 FT-LBS TORQUE 3/4" DIAMETER NUTS 24 FT-LBS TORQUE FIBERGLASS PANEL NOTES: - FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN. - PANELS TO BE MINIMUM 1/4" THICKNESS. 1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF TRANSPARENT MATERIALS. 2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED APPEARANCE. 3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT. 4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT. 5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS: STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS. 6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE ULTRAVIOLET PROTECTION. 7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN. 8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS. PROPOSED RRH WITHIN PENTHOUSE PROPOSED OVP WITHIN PENTHOUSE 1 Z-7 PENTHOUSE CONCEALMENT DETAILS SCALE: 1/2"=1'-0" NOTE: PROPOSED FRAMING AND ATTACHMENT DETAILS NOT SHOWN FOR CLARITY. SB ICV VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP SB ICV VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP VP THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-8 LANDSCAPING PLAN - EXISTING SCALE: 1"=10'-0" S ET D VP VP VP S ET D VP VP VP THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 Z-9 LANDSCAPING PLAN - EXISTING SCALE: 1"=10'-0" LANDSCAPING PLAN (CONTINUED) Z-9 14 2 Z-9 LANDSCAPING PLAN - PROPOSED SCALE: 1"=10'-0" EXISTING WALKWAY NOTE: - A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. - ALL EXISTING TREES TO REMAIN AND BE PROTECTED. DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: 3'-0" 6'-0" 2'-10" 3'-0" 2'-10" FRONT VIEW LEFT SIDE VIEW TOP VIEW FRONT VIEW LEFT SIDE VIEW TOP VIEW 6'-0" 2'-6" 2'-10" 2'-6" 2'-10" 2'-0" 5" 1'-1" EQUIPMENT DETAILS Z-10 15 DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING 1 Z-10 RBA72 CABINET DETAIL SCALE: 1"=1'-0" 2 Z-10 RBA72-36 CABINET DETAIL SCALE: 1"=1'-0" NOTE: DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING M LOAD CENTER PROPOSED 200A LOAD CENTER EXISTING 120/208 V 3Ø 500kVA TRANSFORMER (FAULT = TBD) PROPOSED 3" PVC CONDUIT WITH (4) TBD CU CONDUCTORS (LENGTH = ±80'-0") PROPOSED 200A METER PROPOSED 200A, 3ɸ NEMA 3R DISCONNECT PROPOSED (4) TBD CU CONDUCTORS & (1) #6 CU GROUND IN TBD EMT CONDUIT (LENGTH = ±200-0") 1 Z-11 ONE-LINE DIAGRAM N.T.S 2 Z-11 ILC PANEL SCHEDULE N.T.S ONE-LINE DIAGRAM & PANEL SCHEDULE Z-11 16 ET E E E E E E E E E E E E E E E E E E E E E E E E E F F F F F F F F F F F F F F F F F F E SS SS SS SS SS SS SS SS SS SS E E E E E E E E E E E E E E DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING 1 Z-12 UTILITY PLAN SCALE: 1/16"=1'-0" UTILITY PLAN Z-12 17 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 16 0 8 16 32 64 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING BUILDING UTILITY PLAN SCHEDULE QUANTITY 1 POWER NOTES: 1. SERVICE SHALL BE 120/208V, 3ɸ, 4W, 200A 2. CONTRACTOR TO COORDINATE INSPECTION AND PLACEMENT OF METER WITH THE LOCAL UTILITY COMPANY: FTC L&P CONTACT: PHONE: W.O. NUMBER: TBD ITEM LENGTH PROVIDED BY INSTALLED BY TRANSFORMER - FTC L&P FTC L&P DESCRIPTION EXISTING 120/240V, 1ɸ, 3W, 50kVA 1 CONDUITS - LINE TO METER 3" PVC 80'± CONTRACTOR 3 CONDUCTORS - LINE TO METER (4) - TBD CU CONDUCTORS 85'± CONTRACTOR CONTRACTOR CONTRACTOR 1 METER SOCKET TYP - CONTRACTOR CONTRACTOR 1 METER TYP - FTC L&P FTC L&P PROPOSED (4) - TBD AWG CU CONDUCTORS IN 3" CONDUIT (LENGTH = 80'-0") PROPOSED 200A METER FAULT: X,XXXA (L-L) POWER FROM EXISTING 500kVA, 120/208V, 3ɸ TRANSFORMER PROVIDED BY FTC L&P PROPOSED 200A, 3ɸ, NEMA 3R DISCONNECT FAULT: X,XXXA (L-L) PROPOSED 200A, METER DISCONNECT FAULT: X,XXXA (L-L) 2 200A, 3ɸ DISCONNECT TYP - CONTRACTOR CONTRACTOR PROPOSED ELECTRICAL RUN ACROSS BUILDING ROOFTOP FROM DISCONNECT TO EQUIPMENT CABINET (LENGTH = 270'-0") Know what's below. Call before you dig. GROUND ROD BLDG STEEL WATER MAIN PROPOSED #6 CU SERVICE ENTRY GROUND PROPOSED 200A METER DISCONNECT PANEL CIRCUIT AND LOAD SCHEDULE LOAD LOAD PER PHASE (VA) PHASE A B C DESCRIPTION QTY. UNIT V.A. LOADS CONTINUOUS LOADS N0N-CONTINUOUS TRIP POLES WIRE SIZE A.I.C. 10,000 THHN WIRE TYPE - - 10,000 THHN 10,000 THHN 10,000 THHN SUBTOTAL CONTINUOUS 4222 - - - VOLTAGE: 120/208 CYCLE: 60 PHASE: 3 WIRE: 4 NEUTRAL: 200 AMPS MAIN BREAKER: 200 AMP FRAME MAIN LUGS: AMPS MAINS: TOP BOTTOM A.I.C.: 22000 TRIP: 200 AMPS MAIN COPPER BUS: 200 AMPS X SERVICE: DESIGNATION: LOCATION: LOAD PER PHASE (VA) LOAD PHASE A B C DESCRIPTION QTY. UNIT V.A. LOADS CONTINUOUS LOADS N0N-CONTINUOUS TRIP POLES WIRE SIZE A.I.C. THHN 10,000 WIRE TYPE - - SUBTOTAL CONTINUOUS 9580 8180 TOTAL 5200 9422 120/208 VAC N/A N/A NO EQUAL: APPROVED EQUAL: MOUNTING: SURFACE: X FLUSH: TOTAL KVA CONTINUOUS x 1.25 TOTAL KVA NON-CONTINUOUS TOTAL KVA TOTAL AMPS BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU BLK RED BLU 200A S G S N #4 TEMP. BOND #TBD #TBD 120/208 VAC 3Ø 200 AMP SERVICE SUPPLIED & INSTALLED BY SITE ELECTRICAL CONTRACTOR 4380 2980 X 1400 1400 1400 HVAC #1 RECTIFIER #5 RECTIFIER #6 RECTIFIER #7 RECTIFIER #8 SPARE SPARE SPARE HVAC #2 1400 1 1400 1400 1400 - - - - - - 1 1 1 1 1 1400 1400 1400 1400 1000 1000 1000 1000 1400 1400 1400 1400 1400 1000 1000 1000 1000 1400 1400 1 1 1 RECTIFIER #1 1400 1400 RECTIFIER #2 RECTIFIER #3 1400 1400 RECTIFIER #4 - 1 1400 1400 GFCI RECEPTACLES SPARE - 180 SPARE TELCO BOX RECEP. LIGHT SPARE SPARE - 180 22 - - 1 1 1 1400 1400 1400 1400 1400 1400 1400 1400 180 180 22 - - - - - - - - - - - - - - - - - 5200 5200 33.98 0 33.98 94.2 X 30A 2 10 X X 30A 2 10 10,000 THHN X 30A 2 10 10,000 THHN X 30A 2 10 10,000 THHN - - - - - - X X X - - - - 10 2 30A THHN 10,000 10 2 30A X THHN 10,000 10 2 30A X THHN 10,000 10 2 30A X THHN 10,000 12 2 20A X THHN 10,000 12 2 20A X 20A 1 12 20A 1 12 20A 1 12 MAXIMUM (240) DEKA FAHRENHEIT HT200ET BATTERIES TO BE INSTALLED (UP TO 62.16 GALLONS OF ELECTROLYTE) NOTE: DEKA FAHRENHEIT HT200ET BATTERY (OR APPROVED EQUAL) WEIGHT: 151 LBS 3 Z-10 BATTERY DETAIL N.T.S. CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED UNDERGROUND POWER ROUTE TO EXTERIOR OF BUILDING IN 3" CONDUIT (LENGTH = 80'-0") EXISTING 500kVA, 120/208V, 3ɸ TRANSFORMER PROVIDED BY FTC L&P PROPOSED 5'-0" WIDE UTILITY EASEMENT - PROPERTY OWNER TO VERIZON EXISTING TREE EXISTING BUILDING EXISTING BUILDING EXISTING PARKING LOT EXISTING PARKING LOT EXISTING TREE EXISTING WALKWAY LANDSCAPING PLAN Z-8 13 ANY DISTURBED ORNAMENTAL GRASS, IRRIGATION, AND LANDSCAPE ROCK TO BE REPLACED AFTER CONSTRUCTION 2 Z-8 LANDSCAPING PLAN - PROPOSED SCALE: 1"=10'-0" EXISTING ORNIMENTAL GRASS (TYP) EXISTING WALKWAY EXISTING BUILDING EXISTING SIDEWALK EXISTING ORNIMENTAL GRASS (TYP) EXISTING WALKWAY EXISTING SIDEWALK EXISTING ORNAMENTAL GRASS TO BE REMOVED AND REPLACED FOR FIBER CONDUIT INSTALLATION EXISTING BUILDING NOTE: - A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. - ALL EXISTING TREES TO REMAIN AND BE PROTECTED. DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING UNDERGROUND MEET POINT TO BE COORDINATED WITH FIBER PROVIDER 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING ORNAMENTAL GRASS TO BE RELOCATED TO THE SOUTH FOR FIBER BOX INSTALLATION N APPROXIMATE LOCATION FOR RELOCATED ORNAMENTAL GRASS DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 Z-7 SECTOR B CONCEALMENT DETAILS SCALE: 1/2"=1'-0" PROPOSED ANTENNA WITHIN CONCEALMENT PROPOSED ANTENNA CONCEALMENT (CONCEALMENT TO MATCH EXISTING BUILDING STUCCO) 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) (2) PROPOSED RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP PER SECTOR) TOP OF STRUCTURE 47'-0" AGL GRADE 0'-0" AGL TOP OF STRUCTURE 47'-0" AGL 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING TOP OF EXISTING STRUCTURE 45'-2" AGL PROPOSED VERIZON RAD CL 37'-0" AGL TOP OF EXISTING STRUCTURE 47'-0" AGL GRADE 0'-0" AGL TOP OF EXISTING STRUCTURE 45'-2" AGL 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED ANTENNA CONCEALMENT (TYP ,PAINT TO MATCH) K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING GRADE 0'-0" AGL TOP OF PARAPET 34'-8" AGL TOP OF STRUCTURE 47'-0" AGL TOP OF PARAPET 34'-8" AGL TOP OF STRUCTURE 47'-0" AGL 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 6x12 HYBRIFLEX B 170° C 230° COAX HYBRIFLEX 1/2" 6x12 1 1 90' SECTOR A VZW ANTENNA AZ= 350° SECTOR C VZW ANTENNA AZ= 230° PROPOSED CABLE TRAY (TYP) PROPOSED HYBRID RUN FROM EQUIPMENT CABINET TO ROOFTOP OVP'S PROPOSED 10'X10' LEASE AREA BY VERIZON PROPOSED EQUIPMENT CABINET (TYP OF 2) PROPOSED TRAFFIC PAD (TYP) PROPOSED FIBER IN CONDUIT ACROSS ROOF TO CABLE TRAY PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 3, SECTOR A & C ONLY) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP) (2) PROPOSED RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP) EXISTING ACCESS HATCH PROPOSED ANTENNA PENTHOUSE (SEE SHEET Z-7) 50' 90' PROPOSED ACCESS HATCH B 170° 80' 1 6x12 HYBRIFLEX DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING 1/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 4 0 2 4 8 16 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED NEW POWER RUN UNDERGROUND FROM EXISTING TRANSFORMER TO NEW ELECTRICAL METER ON SIDE OF BUILDING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 6 8 10 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED ANTENNA CONCEALMENT (TYP) (PAINT TO MATCH) VP VP VP VP VP THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 Z-1 SITE PLAN SCALE: 1"=20'-0" SITE PLAN Z-1 6 PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 3 PER SECTOR, SECTOR A & C ONLY) PROPOSED ANTENNA PENTHOUSE SHROUD (SEE SHEET Z-7) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 1 PER SECTOR) PROPOSED 10'X10' LEASE AREA BY VERIZON PROPOSED EQUIPMENT CABINET (TYP OF 2) PROPOSED FIBER VAULT "10' UTILITY AND ACCESS EASEMENT - PROPERTY OWNER TO VERIZON" PROPOSED FIBER RUN (UNDERGROUND TO SIDE OF BUILDING) 2 PH-2 2 PH-1 (2) PROPOSED, (2) FUTURE RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP PER SECTOR) "5' UTILITY EASEMENT - PROPERTY OWNER TO VERIZON" EXISTING 30'-0" WIDE EMERGENCY ACCESS, PUBLIC ACCESS, UTILITY AND DRAINAGE EASEMENT. RECEPTION # 20160069113 EXISTING 8'-0" WIDE UTILITY AND DRAINAGE EASEMENT. RECEPTION # 20160069113 EXISTING PUBLIC ACCESS EASEMENT. RECEPTION # 20160069113 EXISTING 15'-0" WIDE UTILITY AND DRAINAGE EASEMENT. RECEPTION # 20160069113 EXISTING 5'-0" WIDE NON-VEHICULAR PUBLIC ACCESS EASEMENT. RECEPTION # 20160069113 EXISTING 5'-0" WIDE UTILITY AND DRAINAGE EASEMENT. RECEPTION # 20160069113 EXISTING STORM DRAIN PIPE (TYP) EXISTING GAS LINE (TYP) DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING EXISTING ROOFTOP ACCESS HATCH EMERGENCY POINT OF EXIT EXISTING ADDRESS MOUNTED TO WALL 2 Z-4 2 Z-6 2 Z-5 1 inch = 20ft. ( IN FEET ) GRAPHIC SCALE 20 0 10 20 40 80 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) NOTE: - A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. - ALL EXISTING TREES TO REMAIN AND BE PROTECTED. PROPOSED NEW POWER RUN UNDERGROUND FROM EXISTING TRANSFORMER TO NEW ELECTRICAL METER ON SIDE OF BUILDING "5' UTILITY EASEMENT - PROPERTY OWNER TO VERIZON" PROPOSED ELECTRICAL RUN ACROSS BUILDING ROOFTOP FROM DISCONNECT TO EQUIPMENT CABINET 3. STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE. STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR. 4. THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE. 5. SUBJECT TO APPROVAL BY THE CITY FORESTER - STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS. TREE PROTECTION NOTES: 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTRUBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUISNESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (1/2) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RAHTER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. GENERAL LANDSCAPE NOTES: 1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP EQUIVALENT. 2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. IRRIGATION SYSTEMS TO BE TURNED OVER TO THE CITY PARKS DEPARTMENT FOR MAINTENANCE MUST BE APPROVED BY THE PARKS MANAGER AND MEET PARKS IRRIGATION STANDARDS. DESIGN REVIEW SHALL OCCUR DURING UTILITIES DEPARTMENT IRRIGATION REVIEW PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AND CONSTRUCTION OBSERVATION AND INSPECTION BY PARKS SHALL BE INCORPORATED INTO THE CONSTRUCTION PROCESS. 3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING. 4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE TOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT (8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX (6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132. 5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE. 6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION. 7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. 8. THE FOLLOWING SEPERATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES: 40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS. 15 FEET BETWEEN ORNAMENTAL TREES AND STREET LIGHTS. 10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES. 6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES. 4 FEET BETWEEN SHRUBS AND PUBLIC WATER, AND SANITARY AND STORM SEWER LINES. 4 FEET BETWEEN TREES AND GAS LINES. 9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a). TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING SKYLIGHT HVAC UNIT AC SECURITY CAMERA VENT PIPE VP BOLLARD COMM DISH 2 GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 03/22/19. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. 18. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 19. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988) 20. THE PROPOSED DEVELEPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 21. THE PROPOSED DEVELEPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 EQUIPMENT PLAN Z-4 ELEVATIONS PROJECT DESCRIPTION 1. INSTALL (1) NEW ANTENNA PENTHOUSE & (3) ANTENNA CONCELAMENT SCREENS. 2. INSTALL (9) NEW 8' ANTENNAS AND (6) RRHS. 3. INSTALL CABLE TRAYS TO RUN HYBRIFLEX TO PROPOSED EQUIPMENT. 4. INSTALL (2) NEW EQUIPMENT CABINETS. 5. INSTALL (3) NEW OVPS. 6. INSTALL NEW FIBER VAULT AND RUN FIBER THROUGH EXTERIOR CONDUIT TO PROPOSED EQUIPMENT. 7. INSTALL NEW TRAFFIC MATS ON THE ROOF 8. RUN NEW POWER TO PROPOSED EQUIPMENT. 9. INSTALL NEW COAX CABLES. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: HIGH DENSITY MIXED-USE NEIGHBORHOOD DISTRICT APN: 9714321001 PARCEL SIZE: 62,564 S.F. ELEVATION: 5028.7' (NAVD 88) STRUCTURE TYPE: EXISTING STRUCTURE STRUCTURE HEIGHT: 47'-0"± AGL ANTENNA RAD CENTER: SECTOR A & C: 39'-5"± AGL SECTOR B: 37'-0"± AGL APPLICANT: VERIZON WIRELESS REAL ESTATE APPLICANT CONTACT: BRANDON KISER 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 PH: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 LEGAL DESCRIPTION LOT 1, THE SLAB PROPERTY, COUNTY OF LARIMER, STATE OF COLORADO Z-5 PH-1 PHOTOSIMULATION VIEWS PH-2 PHOTOSIMULATION VIEWS (CONTINUED) Z-3 EQUIPMENT PLAN (CONTINUED) Z-6 ELEVATIONS (CONTINUED) ELEVATIONS (CONTINUED) Z-7 CONCEALMENT DETAILS PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION GN-1 GENERAL NOTES Z-8 LANDSCAPING PLAN DRAWING SHEET: SITE INFORMATION: OF 17 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING H 03-27-19 RPH REVISED ZONING I 04-11-19 LCW REVISED ZONING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0093 J 04-15-19 GAC REVISED ZONING K 05-03-19 GAC REVISED ZONING L 05-29-19 RPH REVISED ZONING M 06-06-19 RPH REVISED ZONING Z-10 EQUIPMENT DETAILS GN-2 GENERAL NOTES (CONTINUED) Z-12 UTILITY PLAN Z-11 ONE-LINE DIAGRAM AND PANEL SCHEDULE Z-9 LANDSCAPING PLAN (CONTINUED)