Loading...
HomeMy WebLinkAboutGROWTH LEASING COLORADO - BDR190008 - SUBMITTAL DOCUMENTS - ROUND 2 - LANDSCAPE PLANVAULT ELEC E VAULT F.O. S C S OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU X CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E E E E FO VAULT ELEC E VAULT F.O. S C OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU X CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV E E E E E E USE OF THE INFORMATION CONTAINED IN THIS INSTRUMENT FOR OTHER THAN THE SPECIFIC PURPOSE FOR WHICH IT WAS INTENDED AND FOR OTHER THAN THE CLIENT FOR WHOM IT WAS PREPARED IS FORBIDDEN UNLESS EXPRESSLY PERMITTED IN WRITING IN ADVANCE TO LOGAN SIMPSON DESIGN INC., AND LOGAN SIMPSON DESIGN INC. SHALL HAVE NO LIABILITY TO ANY USE OF THIS INFORMATION WITHOUT THEIR WRITTEN CONSENT. NOTE TO CONTRACTOR LOGAN SIMPSON DESIGN INC. HAS ENDEAVORED TO PROVIDE ACCURATE UTILITY INFORMATION BASED ON THE MOST CURRENT DATA AVAILABLE. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF UNDERGROUND UTILITIES SHOWN OR NOT SHOWN ON THESE PLANS WITH RESPECT TO LINE AND GRADE PRIOR TO CONSTRUCTION. Lot 17, Block 3 Replat of Evergreen Park 1237 Red Cedar Circle Fort Collins, CO GROWTH LEASING COLORADO LANDSCAPE ARCHITECT DATE: CHECKED BY: DRAWN BY: DESIGNED BY: 04.02.19 JG/AC AC JG/SS SEAL: CLIENT: GROWTH LEASING 3019 Duportail Street, #177 Richland, WA 99352 p. 505-570-7745 CIVIL ENGINEER: NORTHERN ENGINEERING 301 N. Howes Street, Suite 100 Fort Collins, CO 80521 p. 970-372-7809 REVISION DATE PER ROUND 1 CITY COMMENTS 5/15/19 L1.1 LANDSCAPE NOTES SHEET 2 OF 2 1. All plants shall conform to all applicable standards of the latest edition of the "American Association of Nurserymen" standards (AAN) as well as local codes and regulations. All plant stock shall be individually tagged as to name and size in accordance with standard practice. 2. Nursery stock shall be healthy, well branched and rooted, formed true to variety and species, full foliaged, free of disease, injury, defects, insects, weeds and weed roots. Trees shall have straight trunks, symmetrical tips, and have an intact single leader. 3. Quality Assurance: Use adequate numbers of skilled workers who are thoroughly trained and experienced in the necessary horticultural practices and who are completely familiar with the specified requirements and methods needed for the proper performance of the work of this section. 4. Discrepancies: The Contractor shall review the drawings prior to installation and notify the Owner's Representative and the Landscape Architect of any discrepancies prior to proceeding with any work. 5. Substitutions: Only as approved by the Landscape Architect. Substitutions not approved by the Landscape Architect will not be accepted at the time of final walk through. 6. Guarantee and Acceptance: All plant material shall be guaranteed by the Contractor for one full year from final acceptance. During this period the contractor shall replace any plant material that is not in good condition and producing new growth. 7. Landscape Contractor shall keep on site for Owner's Representative's inspection, all receipts for soil amendment and topsoil delivery. 8. Existing Tree Protection: Prior to construction, barriers shall be erected around all existing trees within the limit of work that are to remain. Such barriers shall be orange fencing a minimum of four (4) feet in height, secured with metal t-posts, no closer than six (6) feet from the trunk or one-half (1 2) of the drip line, whichever is greater. The spacing of stakes shall be ten (10) feet. 01 - First Floor Plan 100' - 0" T.O. CMU - East 114' - 8" P5 P2 P2 P1 P4 P5 P5 W2 W3 R1 W1 01 - First Floor Plan 100' - 0" T.O. Parapet 120' - 0" T.O. CMU - West 110' - 0" P9 P3 P4 W3 W1 R1 Beyond P1 01 - First Floor Plan 100' - 0" T.O. Parapet 120' - 0" T.O. CMU - West 110' - 0" T.O. CMU - East 114' - 8" P3 P5 P2 P5 P5 P7 P6 P6 P7 P7 P9 P4 P4 P4 P8 W2 W1 W3 W2 W3 01 - First Floor Plan 100' - 0" T.O. Parapet 120' - 0" T.O. CMU - West 110' - 0" T.O. CMU - East 114' - 8" P1 P4 P1 P2 P2 P3 P3 P3 P9 P4 A2.0A 2 A2.0A 5 A2.0A 3 A2.0A 4 3 yard dumpster Generator 16' - 0" 10' - 0" 11' - 4" 9' - 4" 10' - 0" 6' - 0" 4' - 0" Hazmat Utility Ethanol Storage housing w/ 2ndary containment on foundation. Butane Storage Rack Propane Storage Rack CO2 Storage on foundation 4' - 8" Perimeter galvanized 3x3x1/4 angle anchored to slab for wall protection 6" concrete filled steel bollards at 42" AFF set in concrete steel handle w/ padlock hasp Man gate Fencing. See landscape drawings Fencing. See landscape drawings 01 - First Floor Plan 100' - 0" P10 P10 P3 P3 W5 P3 W5 W5 Concrete filled steel bollards set in concrete. Painted traffic yellow 6' - 8" 3' - 4" 6' - 0" 4' - 0" 5' - 4 3/8" 10' - 7 5/8" 11' - 4" 37' - 4" P10 P3 P3 P3 VAULT ELEC E VAULT F.O. S C X ST ST DS DS 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Photometric Red Cedar Circle Fort Collins, Colorado Leasing Industrial Growth No. Description Date APS CMP APS 215-19 1 Photometric Plan 4-02-2019 Site P2.0 PHOTOMETRIC CUT-SHEETS 0.1 0.2 0.3 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.4 0.4 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.8 1.6 2.0 2.1 2.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 0.8 2.0 3.8 4. .8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.0 0.0 1. 2.6 3.4 3.8 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 1.2 1.7 2.2 2.3 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.4 0.4 0.4 0.4 0.4 0. 0.4 0.0 1.0 1.0 1.1 1.0 0.0 0.0 0.0 0.1 0.2 0.3 0.6 1.0 1.4 1.3 1.3 1.3 1.2 0.8 0. 0.9 0.7 0.7 0.7 0.1 0.0 0.0 0.1 0.2 0. 0.8 1.4 2.1 2.6 2.6 2.4 1.6 1.4 1.4 1.0 0.6 0. 0.4 0.1 0.0 0.0 0.1 0.2 0. 0.9 1.7 2. 4.2 4.7 3.1 1.8 2.7 2.2 1.3 0.7 0.4 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 3.2 2. 1.6 0.8 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 . 3.1 1. 0.7 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 .6 3.2 1. 0.7 0.3 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 3. 2.7 1.6 0.8 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.0 2.7 1.9 1.1 0.6 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.2 0.1 3.0 1.3 0.8 0. 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.3 1.7 .1 1. 0.9 0. 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.4 2.6 7.4 2.1 1.3 0.7 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.7 6.1 .2 2.8 1.9 0.7 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.7 4.3 7.1 3.6 1.7 0.6 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.4 2.3 6.9 3.7 1.7 0.6 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.3 1.2 4.8 2.7 1.8 0.7 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.0 1.7 1.7 1.4 0.8 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.0 1.3 1.4 1.2 0.7 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 1.7 1.9 1. 0.9 0. 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 4.6 3.1 2.1 1.2 0.6 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 6.0 4.1 2.3 1.1 0. 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.9 2.8 6.1 6.9 4.0 6.3 4.1 2.2 1.0 0. 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.3 1.0 1.8 3.2 3.9 1.9 4.0 3. 2.0 1.1 0. 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.1 1.6 1.7 1.3 0.7 0.4 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.4 0. 0. 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 AA-RCO BB3 BB4 BB3 BB4 CC2 CC2 CC2 CC2 Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Photometric Red Cedar Circle Fort Collins, Colorado Leasing Industrial Growth No. Description Date APS CMP APS 215-19 1 Photometric Plan 4-02-2019 Site 1 PHOTOMETRIC SITE PLAN P1.0 PHOTOMETRIC PLAN REQUIRES REVIEW AND APPROVAL BY STRUCTURAL ENGINEER 2 POLE BASE DETAIL Statistics Description Symbol Ag Ma Min MaMin AgMin Calc one #3 0.7 c 7.4 c 0.0 c NA NA Schedule Symbol Label Quantity Manuacturer Catalog Number Description Lamp Number Lamps Filename Lumens Per Lamp Light Loss Factor Wattage AA- RCO 1 Lithonia Lighting DSX0 LED P 30 RCCO MVOLT DSX0 LED P 30 RCCO MVOLT LED 1 DSX0LEDP3 0RCCOMVOL T.ies 6614 1 89 BB3 2 Lithonia Lighting DSXW2 LED 30C 700 30 T3M MVOLT DSXW2 LED WITH 3 LIGHT ENGINES, 30 LEDs, 700mA DRIVER, 3000 LED, TYPE 3 MEDIUM OPTIC LED 1 DSXW2LED30 C70030T3M MVOLT.ies 763 1 71 BB4 2 Lithonia Lighting DSXW2 LED 30C 700 30 TFTM MVOLT DSXW2 LED WITH 3 LIGHT ENGINES, 30 LEDs, 700mA DRIVER, 3000 LED, TYPE FORWARD THROW MEDIUM OPTIC LED 1 DSXW2LED30 C70030TFT MMVOLT.ies 727 1 71 CC2 4 Lithonia Lighting DSXW1 LED 20C 30 30 T2M MVOLT DSXW1 LED WITH (2) 10 LED LIGHT ENGINES, TYPE T2M OPTIC, 3000, @ 30mA. LED 1 DSXW1LED20 C3030T2M MVOLT.ies 3887 1 34.9 Luminaire Locations No. Label X Y Location MH Orientation Tilt X Y Aim 3 AA-RCO 29.97 301.08 20.00 20.00 180.33 0.00 29.96 300.00 0.00 1 BB4 30.80 242.20 13.00 13.00 0.00 0.00 30.80 242.33 0.00 2 BB4 01.80 246.90 13.00 13.00 0.00 0.00 01.80 247.03 0.00 14 BB3 431.39 247.70 13.00 13.00 0.00 0.00 431.39 247.82 0.00 16 BB3 332.32 217.67 13.00 13.00 270.00 0.00 332.20 217.67 0.00 4 CC2 46.61 241.76 8.00 8.00 0.36 0.00 46.61 241.76 0.00 CC2 402.91 242.06 8.00 8.00 0.36 0.00 402.91 242.06 0.00 6 CC2 04.26 227.40 8.00 8.00 89.02 0.00 04.26 227.40 0.00 7 CC2 418.69 188.94 8.00 8.00 180.74 0.00 418.69 188.94 0.00 W5 W5 W5 Butane and propane storage lockers. Secured and locked. 19' - 4" 4' - 8" H3 Hazmat Storage Building on skid w/ foundation Concrete filled steel pip bollard, typical per plan. Propane and Butane storage lockers secured to concrete 10' - 0" 6' - 8" W5 W5 P3 P3 6' - 8" 3' - 4" 10' - 0" 9' - 4" 19' - 4" W5 W5 P3 P3 Concrete filled steel pip bollard. Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Contact: Blake Larsen Email: blake@larsensd.com Larsen Structural Design Phone: (970) 568-3355 Fort Collins, CO 80524 19 Old Town Square, Suite 238 Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80524 223 Linden St. Suite 204 Mech/Plumbing Engineer Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Contact: Jennifer Gardner Email: jgardner@logansimpson.com Logan Simpson Phone: 970-449-4100 #4827 Fort Collins, CO 80524 213 Linden Street, Ste. 300 Planning & Entitlement Contact: Danny Weber Email: danny@northernengineering.com Northern Engineering Phone: 970-568-5418 Fort Collins, CO 80521 301 N Howes Street Civil Engineer Contact: Tom Orfanos Email: torfanos@growthleasing.com Growth Leaseing, LLC Phone: 505-570-7745 City, State, Zip Address Owner Contact: - Email: - TBD Phone: # City, State, Zip Address General Contractor Author Checker A2.0A Enclosure Plans and Elevations Planning Resubmittal 2019-01 Growth Leasing No. Description Date 2 Planning Resubmittal 5/15/2019 1/4" = 1'-0" 1 Enlarged Trash Enclosure Plan 1/4" = 1'-0" 2 Trash Enclosure - North Elevation 1/4" = 1'-0" 3 Trash Enclosure - South Elevation 1/4" = 1'-0" 4 Trash Enclosure - East Elevation 1/4" = 1'-0" 5 Trash Enclosure - West Elevation Asphalt drive Sloped concrete pad R1 W1W2 W3W2 W1 W3 W3 CMU Splitface Block Manuf: Colorado Best Block Product: 8 x 12 x 16 Splitface CMU Color: TBD Notes: provide precast concrete cap at top of CMU Hard Coat Stucco Manuf: Sto Product: PowerWall Main Color: TBD Accent Color: TBD Metal Panel Manuf: Berridge Product: S-Deck Color: TBD Standing Seam Metal Roof Manuf: Berridge Product: "Cee-lock" standing seam Color: TBD Exterior Material Legend W1 W2 W3 R1 Issued Drawing Number Scale Accordingly if Reduced Project No.: Drawn by: Reviewed by: In Association with: ARCHITECTS r4 architects.com 226 Remington Unit #3 Fort Collins, CO 80524 phone 970/224-0630 www.r4architects.com Contact: Blake Larsen Email: blake@larsensd.com Larsen Structural Design Phone: (970) 568-3355 Fort Collins, CO 80524 19 Old Town Square, Suite 238 Structural Engineer Contact: Tom Segelhorst Email: Thomas-s@int-mech.com Integrated Mechanical Phone: (970)556-0570 Fort Collins, CO 80524 223 Linden St. Suite 204 Mech/Plumbing Engineer Contact: Chuck Polson Email: chuck@apsinc.biz APS, Inc. Phone: (970) 381-7462 Highlands Ranch, CO 80129 9249 S. Broadway, #200-836 Electrical Engineer Contact: Jennifer Gardner Email: jgardner@logansimpson.com Logan Simpson Phone: 970-449-4100 #4827 Fort Collins, CO 80524 213 Linden Street, Ste. 300 Planning & Entitlement Contact: Danny Weber Email: danny@northernengineering.com Northern Engineering Phone: 970-568-5418 Fort Collins, CO 80521 301 N Howes Street Civil Engineer Contact: Tom Orfanos Email: torfanos@growthleasing.com Growth Leaseing, LLC Phone: 505-570-7745 City, State, Zip Address Owner Contact: - Email: - TBD Phone: # City, State, Zip Address General Contractor Author Checker A2.0 Exterior Elevations Planning Resubmittal 2019-01 Growth Leasing 1/8" = 1'-0" 1 East Building Elevation 1/8" = 1'-0" 2 West Building Elevation 1/8" = 1'-0" 3 North Building Elevation 1/8" = 1'-0" 4 South Building Elevation Keynote Legend Keynote Keynote Text P1 Gutters and open face downspouts to concrete splash block. Color: Dark Bronze P2 Painted steel columns and canopy beams, Color: Dark Bronze P3 Prefinished cap flashing P4 Ground face CMU block at top of wall and at all headers P5 Storefront entry and windows, color: Dark Bronze P6 Insulated overhead coiling doors, color: TBD P7 Insulated hollow metal doors and frames, color: Dark Bronze P8 Mechanical louver, Color: Dark Bronze P9 Mechanical screen for roof top equipment P10 Trash enclosure gates, color: Dark Bronze No. Description Date 1 Planning Submittal 04/02/2019 2 Planning Resubmittal 5/15/2019 5 Perspective Looking SW There shall be no storage or movement of equipment, material, debris, or fill within the fenced tree protection zone. 9. Topsoil and Final Grades: Landscape Contractor is to verify that the topsoil is or is not conducive to proper plant growth. Landscape Contractor is to supply and place 8" of topsoil in planting area if topsoil on site is not conducive to proper plant growth, unless otherwise notified by General Contractor. 10. Herbicides: Prior to soil preparation, all areas showing undesirable weed or grass growth shall be treated with Round-up in strict accordance with the manufacturer's instructions. 11. Soil Amendment: All shrub planting beds and turf areas shall be amended uniformly with Type 1 organic compost at a rate of 3 CY / 1000 SF. 12. Soil Preparation: Work all planting areas by rototilling to a minimum depth of 8 inches. Remove all stones over 1-1/2"size, sticks, mortar, large clumps of vegetation, roots, debris or extraneous matter turned up in working. Soil shall be of a homogeneous fine texture. Level, smooth and lightly compact area to within 0.10 of required grades. 13. Notification: The Contractor shall notify the Owner's Representative 48 hours in advance of installation of the plants for final approval of plant locations. 14. Planting Hole: Lay out plant locations and excavate all soils from planting holes twice the width of the root ball. Loosen soil inside bottom of plant hole. Dispose of any topsoil or debris from excavation. 15. Planting: Place the plant on a layer of lightly compacted planting mix at the center of the planting hole. Plant trees and shrubs upright and orient for best appearance. a. For plants grown in containers, remove container and slice root ball top to bottom in five places equidistant around the circumference to a depth of three inches. b. For balled and burlapped plants, place plant in hole then remove all burlap, cage, plastic or any other items used to secure rootball. c. Stagger plants in rows. Backfill planting hole with 1 part organic compost, 2 parts native topsoil while working each layer to eliminate voids. When hole is approximately two thirds full, water thoroughly, then allow water to soak away. Place remaining backfill and dish surface around plant to hold water. Final grade should keep root ball slightly above surrounding grade, not to exceed one inch. Water again until no more water is absorbed. 16. Steel Edging: Edging between manicured lawn and shrub/perennial planting areas shall be 14 GA x 4" heavy duty roll top steel edger and shall be set level with top of sod. 17. Mulching: Mulch all shrub planting areas with shredded cedar mulch per plan to a min. depth of 3". 18. Manicured Lawn Area: Sod shall be drought tolerant Kentucky Bluegrass mix sod to match existing and consist of healthy, thick turf having undergone a program of regular fertilization, mowing and weed control.Sod shall be free of weeds; uniform in green color, leaf texture and density; healthy; have a vigorous root system; and free of disease, nematodes, pests and pest larvae. Thatch layer shall not exceed one half inch (1 2"), uncompressed. Sod shall be delivered and installed within twenty four (24) hours of being cut. a. Subgrade on which sod is laid shall be slightly moist during installation. b. Lay sod with longest dimension parallel to contours and in continuous rows. c. Tightly butt ends and sides of sod together. Stagger and compact vertical joints between sod strips d. Sod shall not be overlapped or stretched during placement, Exposed joints due to shrinkage will require replacement of sod in affected areas. e. Topsoil: Where new sod abuts an existing turf area, topsoil shall be placed along seams and or joints to provide a smooth transition. f. Rolling: Sod shall be rolled after installation to ensure proper contact with the subgrade, and to ensure tight joints between adjacent pieces, Sod shall be moist prior to rolling. Once rolling is complete, additional watering shall occur. Roller shall weigh one-hundred (100) pounds. g. Water thoroughly with a fine spray as laying progresses and immediately after planting. Saturate sod with fine water spray within two hours of planting. During first week after planting, water daily or more frequently as necessarily to maintain moist soil to a minimum depth of one and one half inches (1-1/2") below sod. GENERAL PLANTING SPECIFICATIONS 19. Native Seed: Deliver seed and packaged materials in original unopened containers bearing weight, analysis and name of supplier. Store in a manner to prevent the materials from becoming wet and deteriorating Seed mix per the varieties and quantities specified on sheet L1.0. a. Do not drill or sow seed during windy, rainy weather or when ground is frozen or otherwise unable to be tilled. b. Seeded area shall be accepted on the basis of having a uniform plant growth over the entire seeded area. Two (2) months after seeding, the seeded area shall be reviewed by the Project Manager and the Contractor. Any area where the seed has failed to germinate shall be re-seeded and raked to cover the seed. 20. Maintenance: All seeded and sodded areas shall be maintained by watering and mowing for a minimum of 60 days after seed is sown or sod is laid. All other areas shall be maintained per the agreed upon contract between the Owner and Contractor. 21. Installation and Final Inspection. The planting of the required landscaping may be delayed for a period up to twelve months after issuance of the certificate of occupancy. Unless all such landscaping is installed, inspected and approved prior to issuance of the certificate of occupancy, a financial security for one hundred twenty-five percent of the landscaping materials and labor costs shall be required to be posted by the developer to ensure the placement of the required landscaping 22. Clean Up: At completion of work, all extra material, supplies, equipment, etc. shall be removed from the site. All areas of the project shall be clean, orderly and complete. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS, AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. STREET TREE NOTES: 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. 3. STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE.STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR. 4. THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE. 5. SUBJECT TO APPROVAL BY THE CITY FORESTER -- STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS. TREE PROTECTION NOTES: 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. GENERAL LANDSCAPE NOTES 1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP OR EQUIVALENT. 2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. IRRIGATION SYSTEMS TO BE TURNED OVER TO THE CITY PARKS DEPARTMENT FOR MAINTENANCE MUST BE APPROVED BY THE PARKS MANAGER AND MEET PARKS IRRIGATION STANDARDS. DESIGN REVIEW SHALL OCCUR DURING UTILITIES DEPARTMENT IRRIGATION REVIEW PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AND CONSTRUCTION OBSERVATION AND INSPECTION BY PARKS SHALL BE INCORPORATED INTO THE CONSTRUCTION PROCESS. 3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING. 4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE THOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT(8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX(6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132. 5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE. 6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION. 7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. 8. THE FOLLOWING SEPARATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES: 40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS 15 FEET BETWEEN ORNAMENTAL TREES AND STREETLIGHTS 10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES 6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES. 4 FEET BETWEEN SHRUBS AND PUBLIC WATER AND SANITARY AND STORM SEWER LINES 4 FEET BETWEEN TREES AND GAS LINES 9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a). 10.PLACEMENT OF ALL LANDSCAPING SHALL BE IN ACCORDANCE WITH THE SIGHT DISTANCE CRITERIA AS SPECIFIED BY THE CITY OF FORT COLLINS. NO STRUCTURES OR LANDSCAPE ELEMENTS GREATER THAN 24" SHALL BE ALLOWED WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENTS WITH THE EXCEPTION OF DECIDUOUS TREES PROVIDED THAT THE LOWEST BRANCH IS AT LEAST 6' FROM GRADE. ANY FENCES WITHIN THE SIGHT DISTANCE TRIANGLE OR EASEMENT MUST BE NOT MORE THAN 42" IN HEIGHT AND OF AN OPEN DESIGN. 11.THE FINAL LANDSCAPE PLAN SHALL BE COORDINATED WITH ALL OTHER FINAL PLAN ELEMENTS SO THAT THE PROPOSED GRADING, STORM DRAINAGE, AND OTHER DEVELOPMENT IMPROVEMENTS DO NOT CONFLICT WITH NOR PRECLUDE INSTALLATION AND MAINTENANCE OF LANDSCAPE ELEMENTS ON THIS PLAN. 12.MINOR CHANGES IN SPECIES AND PLANT LOCATIONS MAY BE MADE DURING CONSTRUCTION -- AS REQUIRED BY SITE CONDITIONS OR PLANT AVAILABILITY. OVERALL QUANTITY, QUALITY, AND DESIGN CONCEPT MUST BE CONSISTENT WITH THE APPROVED PLANS. IN THE EVENT OF CONFLICT WITH THE QUANTITIES INCLUDED IN THE PLANT LIST, SPECIES AND QUANTITIES ILLUSTRATED SHALL BE PROVIDED. ALL CHANGES OF PLANT SPECIES AND LOCATION MUST HAVE WRITTEN APPROVAL BY THE CITY PRIOR TO INSTALLATION. 13.ALL PLANTING BEDS SHALL BE MULCHED TO A MINIMUM DEPTH OF THREE INCHES. REQUIRED MEETINGS AND WARRANTEE: 1. CONTRACTOR SHALL HOLD A PRE-CONSTRUCTION MEETING WITH REPRESENTATIVES OF THE CITY OF FORT COLLINS. 2. CONTRACTOR SHALL ARRANGE FOR OWNER TO INSPECT PLANT MATERIAL BEFORE PLANTING AT EITHER THE NURSERY OR ON SITE. 3. CONTRACTOR SHALL ARRANGE FOR A MINIMUM OF TWO INSPECTIONS DURING INSTALLATION WITH THE OWNERS REPRESENTATIVE. 4. SUBSTANTIAL COMPLETION INSPECTIONS SHALL BE SCHEDULED BY THE LANDSCAPE CONTRACTOR. PUNCH LIST ITEMS SHALL BE IDENTIFIED AND PROVIDED TO THE LANDSCAPE CONTRACTOR BY OWNER PUNCH LIST ITEMS TO BE CORRECTED WITHIN TWO WEEKS OF IDENTIFICATION. 5. LANDSCAPE CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTEE ON PLANT MATERIAL, INCLUDING TREES AND IRRIGATION. LANDSCAPE CONTRACTOR SHALL SCHEDULE TWO INSPECTIONS WITH THE OWNER’S REPRESENTATIVES OF ALL TREES, LANDSCAPE PLANTS AND IRRIGATION, ONE IN JUNE AND ONE IN SEPTEMBER, DURING THE ONE YEAR WARRANTEE PERIOD. THE LANDSCAPE CONTRACTOR SHALL SCHEDULE A FINAL INSPECTION WITH THE OWNER’S REPRESENTATIVES AT THE END OF THE ONE YEAR WARRANTEE PERIOD. LANDSCAPE CONTRACTOR SHALL REPLACE TREES AND LANDSCAPE PLANTS FOUND TO HAVE DIED OR IN POOR CONDITION AT ANY OF THE SITE INSPECTIONS AS DIRECTED BY THE OWNER’S REPRESENTATIVE. PLANT REPLACEMENTS SHALL BE MADE WITHIN TWO WEEKS OF IDENTIFICATION UNLESS DIRECTED OTHERWISE BY THE OWNER’S REPRESENTATIVE. 6. ANY TREE OR LANDSCAPE PLANT THAT IS REPLACED AFTER THE FINAL INSTALLATION INSPECTION SHALL HAVE A FULL WARRANTEE PROVIDED BY THE LANDSCAPE CONTRACTOR FOR ONE YEAR OR THE MAINTENANCE/WARRANTEE PERIOD WHICHEVER IS LONGER. THIS MAY INVOLVE PROVIDING A WARRANTEE ON INDIVIDUALLY IDENTIFIED PLANTS THAT HAVE BEEN REPLACED DURING THE ONE YEAR WARRANTEE PERIOD THAT EXTENDS PAST THE COMPLETION OF THE MAINTENANCE/WARRANTEE PERIOD. LANDSCAPE PLAN NOTES: TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FORM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 Over 19 15 N STAKING: INSTALL 6' METAL T-POST STAKES OUTSIDE PLANTING PIT IN UNDISTURBED MULCHED SOIL. USE #12 GAUGE GALVANIZED WIRE. ALLOW FOR SOME TRUNK MOVEMENT ATTACH TO 2" NYLON STRAPS THROUGH METAL GROMMETS, WITH 1/2" x 15" WHITE PVC SLEEVE ON EACH WIRE. NYLON STRAPS SHALL BE LONG ENOUGH TO ACCOMMODATE 1-1/2" OF TRUNK GROWTH. ADD PROTECTOR CAP TO TOP OF POST. WRAP TREES TO FIRST BRANCH IF PLANTED IN THE FALL. DO NOT WRAP IF PLANTED IN SPRING. INSTALL TRUNK PROTECTOR, DESIGNED TO EXPAND WITH TRUNK GROWTH (DECIDUOUS ONLY). PLANT TREE SUCH THAT FIRST ORDER MAJOR ROOT IS 1" TO 2" ABOVE GRADE AND TRUNK FLARE IS VISIBLE. 4' ABOVE GRADE SIDE SLOPES OF PLANTING HOLE SHALL BE 1:1. ROUGHEN SIDES OF PLANTING PIT PRIOR TO SETTING. PLACE ROOTBALL ON UNDISTURBED SOIL TO PREVENT SETTLEMENT. REMOVE ENTIRE WIRE BASKET, ALL ROPE, TWINE AND BURLAP FROM ROOTBALL AND TRUNK. TREE PLANTING DETAIL 1" = 1" SPECIFIED MULCH (4" DEPTH X 6' DIAMETER) PULLED BACK 6" FROM BASE OF TRUNK. 2X ROOTBALL DIAMETER TREE STAKING PLAN VIEW 3" OR LESS CALIPER MORE THAN 3" CALIPER & ON ALL EVERGREENS BACKFILL PIT WITH MIXTURE OF 2/3 EXISTING SOIL AND 1/3 APPROVED AMENDMENT. WATER THOROUGHLY WHILE BACKFILLING. DO NOT COMPACT OR TAMP. 1 P-CI-LVC-81 SHRUB PLANTING DETAIL NTS BACKFILL PIT WITH MIXTURE OF 2/3 EXISTING SOIL AND 1/3 APPROVED AMENDMENT. WATER THOROUGHLY WHILE BACKFILLING, DO NOT COMPACT OR TAMP. SET ROOTBALL ON NATIVE UNDISTURBED SOIL MULCH PER PLANS 2" DEEP WATERING BASIN SHALL BE GENTLE AND UNIFORM THROUGHOUT WITH NO OBTRUSIVE EDGES. BASIN TO BE 3' IN DIAMETER. 2x WIDTH OF ROOTBALL 2 NOTE: 1. WHEN BACKFILLING AROUND PLANTS, DO NOT ALLOW AIR POCKETS TO FORM 2. AFTER PLANTING, WATER THOROUGHLY SECTION PLAN THOROUGHLY AMEND SOIL TO DEPTH PER SPECIFICATIONS TYPICAL PLANT LAYOUT SEE PLANT LIST NOTES FOR SPACING PERENNIAL/ GRASS PLANTING NTS EQUAL EQUAL MULCH PER PLANS AMENDED SOIL MIX TO DEPTH PER SPECIFICATIONS PLANT MATERIAL 3 NATIVE GRASS SEEDING NOTES: 1. PREPARE SOIL AS NECESSARY AND APPROPRIATE FOR NATIVE SEED MIX SPECIES AND AS OUTLINED IN MUNICIPAL CODE 12_130 THROUGH 12_132. IN NATIVE AREAS THESE REQUIREMENTS ARE TYPICALLY SATISFIED THROUGH SOIL SAMPLES SHOWING QUALITY OF SOIL MEETS THE DEFINITION OF TOP SOIL IN CODE 12_131. THROUGH LOOSENING THE TOP 8 INCHES OF SOIL AND APPLYING 4 INCHES OF TOP SOIL THEN SOIL AMENDMENT REQUIREMENTS CAN BE FULFILLED. 2. AFTER SOIL HAS BEEN PROPERLY PREPARED THEN SEED EVENLY IN TWO DIRECTIONS TO DISTRIBUTE SEED OVER ENTIRE AREA. SEED ALL INDICATED AREAS AS SOON AS POSSIBLE AFTER COMPLETION OF GRADING OPERATIONS. 3. IF CHANGES ARE TO BE MADE TO SEED MIX BASED ON SITE CONDITIONS THEN APPROVAL MUST BE PROVIDED BY CITY ENVIRONMENTAL PLANNER. 4. APPROPRIATE NATIVE SEEDING EQUIPMENT WILL BE USED (STANDARD TURF SEEDING EQUIPMENT OR AGRICULTURE EQUIPMENT SHALL NOT BE USED). 5. GENERALLY DRILL SEED APPLICATION RECOMMENDED PER SPECIFIED APPLICATION RATE TO NO MORE THAN ½ INCH DEPTH (OR APPROPRIATE DEPTH FOR SELECTED SPECIES). WHEN USING BROADCAST SEEDING INSTEAD OF DRILL SEEDING METHOD DOUBLE SPECIFIED APPLICATION RATE. REFER TO NATIVE SEED MIX TABLE FOR SPECIES, PERCENTAGES AND APPLICATION RATES. 6. PREPARE A WEED MANAGEMENT PLAN TO ENSURE THAT WEEDS ARE PROPERLY MANAGED BEFORE, DURING AND AFTER SEEDING ACTIVITIES. 7. AFTER SEEDING THE AREA SHALL BE COVERED WITH CRIMPED STRAW, JUTE MESH, OR OTHER APPROPRIATE METHODS. 8. WHERE NEEDED, TEMPORARY IRRIGATION SHOULD BE PROVIDED UNTIL SEED IS ESTABLISHED. IF IRRIGATION IS USED, THE IRRIGATION SYSTEM FOR SEEDED AREAS SHALL BE FULLY OPERATIONAL AT THE TIME OF SEEDING AND SHALL ENSURE 100% HEAD TO HEAD COVERAGE OVER ALL SEEDED AREAS. ALL METHODS AND REQUIREMENTS IN THE APPROVED IRRIGATION PLAN SHALL BE FOLLOWED.CONTRACTOR SHALL MONITOR SEEDED AREA FOR PROPER IRRIGATION, EROSION CONTROL, GERMINATION AND RESEEDING AS NEEDED TO ESTABLISH COVER. 9. THE APPROVED SEED MIX AREA IS INTENDED TO BE MAINTAINED IN A NATURAL LIKE LANDSCAPE AESTHETIC. IF AND WHEN MOWING OCCURS IN NATIVE GRASS SEED MIX AREAS, DO NOT MOW LOWER THAN 6 TO 8 INCHES IN HEIGHT TO AVOID INHIBITING NATIVE PLANT GENERALLY, MOW NO MORE THAN 3 TO 4 TIMES PER YEAR DURING ESTABLISHMENT PERIOD FOR WEED MANAGEMENT WHEN NECESSARY. 10. NATIVE SEED AREA WILL BE CONSIDERED ESTABLISHED WHEN SEVENTY PERCENT VEGETATIVE COVER IS REACHED WITH NO LARGER THAN ONE FOOT SQUARE BARE SPOTS AND/OR UNTIL DEEMED ESTABLISHED BY CITY PLANNING SERVICES AND EROSION CONTROL. 11. THE DEVELOPER AND/OR LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR ADEQUATE SEEDLING COVERAGE AND GROWTH AT THE TIME OF FINAL STABILIZATION, AS DEFINED BY STATE AND LOCAL AGENCIES. IF FINAL STABILIZATION IS NOT ACHIEVED TO THE SATISFACTION OF THE AGENCY, THE DEVELOPER AND/OR LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL CORRECTIVE MEASURES TO SATISFY FINAL VEGETATIVE REQUIREMENTS FOR CLOSEOUT. E E E E E E FO FO FO FO FO FO FO FO FO FO CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV G G G G G G G G G G G E E E E E E E E E E W W FO FO FO FO FO FO FO FO FO FO 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS ST ST 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W UD UD A eccDbGeneralLabel (AeccLand120) AeccDbGeneralLabel (AeccLand120) AeccDbGeneralLabel (AeccLand120) E E E E E E E VAULT ELEC E C CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV G G G G G G G G G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E W W W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO ST ST ST ST ST 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W U D UD UD UD UD A eccDbGeneralLabel (AeccLand120) E E E E E E E E E E E E E USE OF THE INFORMATION CONTAINED IN THIS INSTRUMENT FOR OTHER THAN THE SPECIFIC PURPOSE FOR WHICH IT WAS INTENDED AND FOR OTHER THAN THE CLIENT FOR WHOM IT WAS PREPARED IS FORBIDDEN UNLESS EXPRESSLY PERMITTED IN WRITING IN ADVANCE TO LOGAN SIMPSON DESIGN INC., AND LOGAN SIMPSON DESIGN INC. SHALL HAVE NO LIABILITY TO ANY USE OF THIS INFORMATION WITHOUT THEIR WRITTEN CONSENT. NOTE TO CONTRACTOR LOGAN SIMPSON DESIGN INC. HAS ENDEAVORED TO PROVIDE ACCURATE UTILITY INFORMATION BASED ON THE MOST CURRENT DATA AVAILABLE. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF UNDERGROUND UTILITIES SHOWN OR NOT SHOWN ON THESE PLANS WITH RESPECT TO LINE AND GRADE PRIOR TO CONSTRUCTION. Lot 17, Block 3 Replat of Evergreen Park 1237 Red Cedar Circle Fort Collins, CO GROWTH LEASING COLORADO LANDSCAPE ARCHITECT DATE: CHECKED BY: DRAWN BY: DESIGNED BY: 04.02.19 JG/AC AC JG/SS SEAL: CLIENT: GROWTH LEASING 3019 Duportail Street, #177 Richland, WA 99352 p. 505-570-7745 CIVIL ENGINEER: NORTHERN ENGINEERING 301 N. Howes Street, Suite 100 Fort Collins, CO 80521 p. 970-372-7809 REVISION DATE PER ROUND 1 CITY COMMENTS 5/15/19 L1.0 LANDSCAPE PLAN SHEET 2 OF 5 0 SCALE: 20 40 60 feet 1" = 20' NORTH EMPLOYEE PARKING DETENTION/LANDSCAPE BUFFER POTENTIAL FUTURE EXPANSION AREA RED CEDAR CIRCLE SYMBOL DESCRIPTION QTY SHREDDED CEDAR MULCH 4,865 SF 3/4" COBBLE MULCH 1,879 SF MULCH SCHEDULE SYMBOL DESCRIPTION QTY SOD 1,692 SF NATIVE SEED 16,186 SF PLANTING SCHEDULE TREES CODE QTY BOTANICAL NAME COMMON NAME CONT CO 3 CELTIS OCCIDENTALIS COMMON HACKBERRY 2" CAL. CA 8 CRATAEGUS AMBIGUA RUSSIAN HAWTHORN 2" CAL. GD 4 GYMNOCLADUS DIOICA `ESPRESSO` KENTUCKY COFFEETREE 2" CAL. PB 12 PICEA PUNGENS `BABY BLUE-EYES` BABY BLUE EYES SPRUCE 6` HT SHRUBS CODE QTY BOTANICAL NAME COMMON NAME CONT AA 8 AMELANCHIER CANADENSIS `AUTUMN BRILLIANCE` AUTUMN BRILLIANCE SERVICEBERRY 5 GAL CK 66 CALAMAGROSTIS X ACUTIFLORA `KARL FOERSTER` FEATHER REED GRASS 5 GAL CN 28 CAREX NEBRASKENSIS NEBRASKA SAGE 1 GAL JB 27 JUNCUS BALTICUS BALTIC RUSH 1 GAL JT 57 JUNCUS TORREYI TORREY`S RUSH 1 GAL PC 30 PHYSOCARPUS OPULIFOLIUS `CENTER GLOW` CENTER GLOW NINEBARK 5 GAL PS 12 PINUS MUGO `SLOWMOUND` MUGO PINE 2" CAL. PLANT SCHEDULE 8874.67 SF BUILDING RAIN GARDEN GARBAGE, GENERATOR & STORAGE TRANFORMER 6' TALL BLACK COATED CHAIN LINK FENCE EXISTING TREES OFF-SITE (TYP) 0 SCALE: 8 16 24 feet 1" = 8' NORTH PLAN ENLARGEMENT OF RAIN GARDEN HYDROZONE WATER USE AREA ANNUAL WATER USE Moderate 10 Gal/SF 6,557 SF 65,570 Gal. Low 3 Gal/SF 18,065 SF 18,132 Gal. TOTAL LANDSCAPE AREA 24,622 SF 83,702 Gal. WATER BUDGET CHART 30% Ephraim Crested Wheatgrass 25% Sheep Fescue 20% Perennial Ryegrass 15% Chewings Fescue 10% Kentucky Bluegrass NATIVE GRASS SEED: Sow at 40 lbs per acre. Over seed with 1lb per 1000 SF of Annual Rye Grass for establishment SPECIES MIX 11% 27% 15% 44% EMPLOYEE PARKING ROLLING SECUTIRY GATE WITH KEY PAD ISLANDS FO FO FO FO FO FO FO CTV CTV CTV CTV CTV CTV CTV CTV CTV G G G G G G G G G G E E E E E E E E E W W FO FO FO FO FO FO FO FO 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS 8" SS ST 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W W W UD A eccDbGeneralLabel (AeccLand120) AeccDbGeneralLabel (AeccLand120) AeccDbGeneralLabel (AeccLand120) E E E E E USE OF THE INFORMATION CONTAINED IN THIS INSTRUMENT FOR OTHER THAN THE SPECIFIC PURPOSE FOR WHICH IT WAS INTENDED AND FOR OTHER THAN THE CLIENT FOR WHOM IT WAS PREPARED IS FORBIDDEN UNLESS EXPRESSLY PERMITTED IN WRITING IN ADVANCE TO LOGAN SIMPSON DESIGN INC., AND LOGAN SIMPSON DESIGN INC. SHALL HAVE NO LIABILITY TO ANY USE OF THIS INFORMATION WITHOUT THEIR WRITTEN CONSENT. NOTE TO CONTRACTOR LOGAN SIMPSON DESIGN INC. HAS ENDEAVORED TO PROVIDE ACCURATE UTILITY INFORMATION BASED ON THE MOST CURRENT DATA AVAILABLE. THE CONTRACTOR SHALL FIELD VERIFY THE LOCATION OF UNDERGROUND UTILITIES SHOWN OR NOT SHOWN ON THESE PLANS WITH RESPECT TO LINE AND GRADE PRIOR TO CONSTRUCTION. Lot 17, Block 3 Replat of Evergreen Park 1237 Red Cedar Circle Fort Collins, CO GROWTH LEASING COLORADO LANDSCAPE ARCHITECT DATE: CHECKED BY: DRAWN BY: DESIGNED BY: 04.02.19 JG/AC AC JG/SS SEAL: CLIENT: GROWTH LEASING 3019 Duportail Street, #177 Richland, WA 99352 p. 505-570-7745 CIVIL ENGINEER: NORTHERN ENGINEERING 301 N. Howes Street, Suite 100 Fort Collins, CO 80521 p. 970-372-7809 REVISION DATE PER ROUND 1 CITY COMMENTS 5/15/19 S1.0 SITE PLAN SHEET 1 OF 3 0 SCALE: 20 40 60 feet 1" = 20' NORTH 8874.67 SF BUILDING EMPLOYEE PARKING (11 SPACES) DETENTION/LANDSCAPE BUFFER 75' TRANSMISSION LINE EASEMENT LOADING DOCK RED CEDAR CIRCLE 9'-0" TYP. 17'-0", TYP. TRASH ENCLOSURE GENERATOR AND STORAGE TRANSFORMER ALLEY RAIN GARDEN BIKE PARKING (4 SPACES) ROLLING SECURITY GATE ROLLING SECURITY GATE 6' TALL BLACK COATED CHAIN LINK FENCE 1. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 2. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 3. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. [IF APPLICABLE -- INCLUDE LANGUAGE FOR ANY MODIFICATIONS AND CONDITIONS APPROVED WITH PDP/ODP]. 7. [IF APPLICABLE] ALL SINGLE FAMILY DETACHED HOMES SHALL MEET OR EXCEED THE GARAGE DOOR STANDARDS AS OUTLINED IN 3.5.2(E) OF THE LAND USE CODE. 8. [IF APPLICABLE] A MINIMUM OF (NUMBER TBD) HOUSING MODELS FOR THE SINGLE FAMILY HOMES SHALL BE REQUIRED. THESE HOUSING MODELS SHALL MEET OR EXCEED THE STANDARDS AS OUTLINED IN 3.5.2(C) OF THE LAND USE CODE. 9. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 10. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 11. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 12. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 13. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSIBLE PARKING SPACES. ACCESSIBLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 14. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY THE PROPERTY OWNER OF THE COMMON AREA. THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 15. DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINAL PLANS, ALL ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER. 16. THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT. 17. PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODOR-CONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 18. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 19. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 20. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. SITE PLAN NOTES: OWNER'S CERTIFICATION: The undersigned does/do hereby certify that I/we are the lawful owner's of the real property described on this site plan and do hereby certify that I/we accept the conditions and restrictions set forth on said site plan. OWNER (SIGNED) DATE (STATE OF ) ( )SS (COUNTY OF ) Subscribed and sworn to be before this Day of 20 , by witness my hand and official seal. NOTARY PUBLIC . ADDRESS . MY COMMISSION EXPIRES . Approved by the Director of Community Development & Neighborhood Services (CDNS) of the City of Fort Collins, Colorado, this of ,20 . DIRECTOR OF CDNS . PLANNING CERTIFICATION: LOT 1, GROWTH LEASING COLORADO, LOCATED IN THE NORTHWEST QUARTER OF SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO GROWTH LEASING COLORADO BASIC DEVELOPMENT REVIEW PLANS FOR: RED CEDAR CIRCLE CONIFER STREET HWY 287 E WILLOX LANE BRISTLECONE DRIVE ALLEY * SITE LOCATION LAND USE TABLE: EXISTING ZONING I - INDUSTRIAL TOTAL PROJECT SIZE 1.09 AC +/-47,480 SF MAX BUILDING HEIGHT 30' PARKING REQUIREMENT 0.5-0.75 SPACES PER EMPLOYEE REQUIRED 20 EMPLOYEES = 10-15 SPACES PROVIDED BIKE PARKING 4 SPACES REQUIRED BY INDUSTRIAL USE 4 SPACES PROVIDED USES Medical marijuana optional premises cultivation operations; Medical marijuana infused product manufacturers; Medical marijuana research and development facility; Facility for medical marijuana research and development cultivation; Medical marijuana testing facility; Retail Marijuana Cultivation Facility; Retail Marijuana Product Manufacturing Facility; and Retail marijuana testing facility. NORTH 24' DRIVE AISLE & EMERGENCY ACCESS EASEMENT 20' ALLEY 8' UTILITY EASEMENT FIRE LANE SIGNS FIRE LANE SIGNS EXISTING OVERHEAD POWERLINES 8' POTENTIAL FUTURE PARALLEL PARKING 6.5' SIDE YARD SETBACK CARD READER FOR MECHANICAL GATE 5' WIDE SIDEWALK 7' WIDE PARKSTRIP PROPOSED 3' RIGHT OF WAY DEDICATION PROPOSED 9' UTILITY EASEMENT LANDSCAPE WALL RETAINING CURB PROPOSED PEDESTRIAN ACCESS EASEMENT ADA RAMP 5' WIDE SIDEWALK EXISTING OFF-SITE TREES