HomeMy WebLinkAboutFOX GROVE PHASE 2 - PDP190002 - DOCUMENT MARKUPS - ROUND 2 - UTILITY PLANSPROSPECT RD.
I-25
MULBERRY ST.
CARRIAGE PKWY
SUNCHASE DR.
KITCHELL WAY
LOCAL RESIDENTIAL
(53' ROW )
FOX GROVE DRIVE
VIXEN DRIVE
BROOK COURT
ROLLINS DEN DRIVE
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
R
FEBRUARY, 2019
UTILITY PLANS FOR
CONTACT INFORMATION
PROJECT TEAM:
UTILITY CONTACT LIST: *
UTILITY COMPANY
* This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for
the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for
locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of
Colorado (UNCC) at 811 for additional information.
PHONE NUMBER
Northern Engineering Services, Inc.
Stephanie Thomas, PE
301 N. Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
NRN O R T H E
I hereby affirm that these final
construction plans were prepared
under my direct supervision, in
accordance with all applicable City
of Fort Collins and State of
Colorado standards and statutes,
respectively; and that I am fully
responsible for the accuracy of all
design. revisions, and record
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
A. GENERAL NOTES
1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County
Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any
applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins.
2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise.
3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of
these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in
these plans.
4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of
said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve
the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless
and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors
and omissions contained in these plans.
5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current
at the date of approval of the plans by the City of Fort Collins Engineer.
6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the
Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer
shall be responsible for unknown underground utilities.
7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or
grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the
respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer
to relocate all existing utilities that conflict with the proposed improvements shown on these plans.
8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility
crossings required.
9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify
the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction.
10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a
timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption
of any utility service as well as the utility companies.
11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification
shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be
required prior to commencement of any work.
12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer
should be constructed prior to installation of the water lines and dry utilities.
13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility.
14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a
storm sewer, channel, irrigation ditch or any waters of the United States.
15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water
Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan.
16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage
facilities shall be the responsibility of the property owner(s).
17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
Boxelder Sanitation District Construction Notes
The following information is condensed from the current “Standard Construction
Specification for Sewer Mains” as adopted by the Boxelder Sanitation District (District)
and is to be considered as such. In the event of any question the full document shall
take precedence.
1. Existing Utility Locates: It shall be the responsibility of the Contractor to
coordinate field locates of all existing utilities prior to commencement of any
construction. Contractor shall also notify all affected utility companies prior to
commencing construction. In the event of damage to any existing utility, the
contractor shall immediately notify the owner of the utility involved and unless
authorized in writing by the owner of the subject utility, shall not attempt to
make repairs. The cost of repairs shall be the responsibility of the Contractor.
2. District Owned Easement Pictures: Contractor to provide sequential digital
pictures spaced at no more than 300 feet detailing conditions of the off-site
Boxelder Owned Easement Conditions and any structures that could be
affected, to the District and the property owner prior to the start of any off-site
These pictures shall include all existing fence, ditches, ditch structures,
out buildings, water troughs, trees and all other landscaping. Pictures are to
be placed at no more than four (4) pictures on a 11x8 sheet of photo paper
inserted into transparent sleeves and delivered with the drawings of record in
a three (3) ring binder.
3. Protection of Property: Contractor shall continuously maintain adequate
protection from damage of all public and private property through which the
work is done.
4. Safety: All sewer main installation within the District shall be subject to
current (Occupational Safety and Heath Association (OSHA) and the
Colorado Safety Association, (CSA) safety requirements. Contractor shall
also comply with any and all requirements and regulations as set forth by
City, County, State and Federal agencies having applicable authority.
5. Start of Construction: No construction shall begin without prior design review
of the District. The District shall be notified 48 hours in advance of starting
construction or testing to allow for scheduling.
6. Road Excavation Permits: In event that State, County or City road excavation
permit(s) are required, the Contractor is responsible for obtaining all road
permits which may be required.
7. Other Permits: The Contractor shall be responsible for obtaining all permits
required for construction.
8. Revisions: No verbal authorization for field revision shall be given. All
requests for field revision shall be made in writing accompanied by proposed
change indicated on copy of the approved design drawings. Any field
revision approved and installed shall also be accurately documented on the
Drawings of Record.
X X X
X
X X X X X
X
X X
X
X
X
" W 8" W
8" W 8" W 8" W
8" W
8" W
8" W
8" W
X
X
G
8" W 8" W 8" W 8" W
8" W
8" W
8" W
8" W 8" W
S S
S
S
S
W
S S
S
S
S
W
W
S S S S
W
W
W
W W
W W
S
S S S S
S
W
W
W
W
W
W
W
W
W
W
HUNTSMAN DR
SUNFLOWER SUBDIVISION
(SINGLE FAMILY)
CW SUBTRUST C/O AGUR FOUNDATION
INDUSTRIAL DISTRICT
(UNDEVELOPED)
LOT 1
LEE MLD
X X X
X
X X X X X
X
X X
X
X
X
" W 8" W
8" W 8" W 8" W
8" W
8" W
8" W
8" W
X
X
G
S S
S
S
S
W
S S
S
S
S
W
W
S S S S
W
W
W
W W
W W
S
S S S S
S
W
W
W
W
W
W
W
W
W
W
53'
ROW
30'
-
53'
ROW
30'
-
53'
ROW
30'
-
53'
53'
ROW
30'
-
53'
ROW
30'
-
53'
ROW
30'
-
53'
ROW
30'
-
6' U.E.
(TYP.)
6' U.E.
(TYP.)
6' U.E.
(TYP.)
6' U.E.
(TYP.)
6' U.E.
(TYP.)
5'
D.G.E.
(TYP.)
5' D.G.E.
(TYP.)
6' UE
5'
D.G.E.
(TYP.)
5'
D.G.E.
(TYP.)
5' D.G.E.
(TYP.)
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
PROPOSED
STORM DRAIN
PROPOSED
INLETS
CONNECT TO
EXISTING STORM
DRAIN
PROPOSED
STORM DRAIN
PROPOSED
INLETS
4915
4920
4925
4930
4935
4915
4920
4925
4930
4935
9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+50
-0.60%
1.50%
-0.59%
0.60%
-0.60%
-0.80%
PVI STA = 10+00.00
PVI ELEV = 4926.69
PVI STA = 13+57.08
PVI ELEV = 4925.52
PVI STA = 17+00.81
PVI ELEV = 4926.06
PVI STA = 14+57.08
PVI ELEV = 4924.92
75.0' VC
HP ELEV = 4926.87
HP STA = 11+12.96
PVI STA = 11+13.06
PVI ELEV = 4926.99
BVCS: 10+75.56
BVCE: 4926.76
EVCS: 11+50.56
EVCE: 4926.76
A.D. = 1.20
K = 62.67
75.0' VC
HP ELEV = 4926.11
HP STA = 16+80.68
PVI STA = 16+63.31
PVI ELEV = 4926.26
BVCS: 16+25.81
BVCE: 4925.70
EVCS: 17+00.81
EVCE: 4926.06
A.D. = 2.05
K = 36.59
60.0' VC
LP ELEV = 4926.59
LP STA = 10+31.65
PVI STA = 10+31.77
PVI ELEV = 4926.50
BCVS: 10+01.77
BVCE: 4926.68
ECVS: 10+61.77
EVCE: 4926.68
A.D. = 1.19
K = 50.47
85.0' VC
LP ELEV = 4924.53
4915
4920
4925
4930
4935
4915
4920
4925
4930
4935
9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 18+50
-2.20%
0.60%
0.55% 0.55%
-1.80%
-1.40%
-1.20%
-0.82%
PVI STA = 10+00.00
PVI ELEV = 4926.58
PVI STA = 10+13.83
PVI ELEV = 4926.28
PVI STA = 10+38.83
PVI ELEV = 4925.83
PVI STA = 10+63.83
PVI ELEV = 4925.48
PVI STA = 17+60.59
PVI ELEV = 4923.67
PVI STA = 17+97.11
PVI ELEV = 4923.87
75.0' VC
HP ELEV = 4925.38
HP STA = 12+90.47
PVI STA = 12+96.22
PVI ELEV = 4925.51
BVCS: 12+58.72
BVCE: 4925.29
EVCS: 13+33.72
EVCE: 4925.21
A.D. = 1.42
K = 52.91
75.0' VC
LP ELEV = 4924.72
LP STA = 11+51.73
PVI STA = 11+39.23
PVI ELEV = 4924.57
BCVS: 11+01.73
BVCE: 4925.02
ECVS: 11+76.73
EVCE: 4924.80
A.D. = 1.80
K = 41.67
75.0' VC
LP ELEV = 4923.01
LP STA = 16+24.95
PVI STA = 16+17.61
PVI ELEV = 4922.89
BCVS: 15+80.11
BVCE: 4923.19
ECVS: 16+55.11
X
X X
X
X X X X X
X
X
X
X X
X
X
" W 8" W
8" W 8" W 8" W
8" W
8" W 8" W
8" W
X
X
G
S
S
S
S
S
W
S
S S
S
S
W
W
S S S S
W
W
W
W W W
W
S S S
S S
S
W
W
W
W
W
W
W
W
W
W
BROOK COURT
ROLLINS DEN DRIVE
VIXEN DR
RAIN GARDEN
DETENTION POND 1
SUNFLOWER SUBDIVISION
(SINGLE FAMILY)
CW SUBTRUST C/O AGUR FOUNDATION
INDUSTRIAL DISTRICT
(UNDEVELOPED)
LOT 1
LEE MLD
(UNDEVELOPED)
FOX GROVE
(SINGLE FAMILY)
EXISTING DETENTION
POND 2
FEMA 100-YR HIGH RISK FRINGE
FOX GROVE DR
BFE: 4926
BFE: 4922
1
1
2
3 2
3
4 4
5
5
6
6
OS1
PROPOSED 7
STORM DRAIN
PROPOSED
INLETS
CONNECT TO
EXISTING STORM
DRAIN
PROPOSED
STORM DRAIN
PROPOSED
INLETS
PROPOSED
UTILITY INLETS
EASEMENT
UTILITY
EASEMENT
3' GRAVEL
SHOULDERS
3' GRAVEL
SHOULDERS
6' GRAVEL
SHOULDER
2' CONCRETE
PAN
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
EXISTING 2'
CONCRETE PAN
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
EXISTING OUTLET
STRUCTURE
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
X
X
KEYMAP
I-25
FOX GROVE DR
VIXEN DR
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
XXXXXXX
FOX OX GROVE DR
VIXEN DR R
DR1
9
NORTH
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
DR1
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's
R
LEGEND:
PROPOSED EASEMENT
EXISTING RIGHT OF WAY
PROPOSED LOT LINE
PROPERTY BOUNDARY
PROPOSED CURB AND GUTTER
PROPOSED SWALE
EXISTING CONTOUR
PROPOSED CONTOUR
PROPOSED STORM INLET
PROPOSED STORM SEWER
EXISTING STORM SEWER
PROPOSED RIGHT OF WAY
A
DRAINAGE BASIN LABEL
DRAINAGE BASIN BOUNDARY
B2
1.45 ac
DESIGN POINT
FLOW ARROWS
1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE
UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST
INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT
GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY
MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED
ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO
CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY
CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS.
2. REFER TO THE "PRELIMINARY DRAINAGE REPORT FOR FOX GROVE
SUBDIVISION SECOND FILING" BY NORTHERN ENGINEERING, DATED
FEBRUARY 13, 2019 FOR ADDITIONAL INFORMATION.
3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM;
NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES.
4. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT
DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER
SURVEY INFORMATION.
NOTES:
BASIN
DESIGNATION
BASIN
AREA (AC)
PROPOSED SWALE 1 1
FLOODPLAIN NOTES:
1. FLOOD ZONE DESIGNATION: ACCORDING TO FEMA MAP NUMBER
08069C1003G, DATED MAY 2, 2012, A PORTION OF THIS TRACT OF LAND IS
WITHIN A FEMA DESIGNATED SPECIAL FLOOD HAZARD AREA (SFHA), AND IS
SUBJECT TO INUNDATION BY THE 1% ANNUAL CHANCE (100-YEAR) FLOOD.
THIS AREA IS ALSO INCLUDED IN A LETTER OF MAP REVISION (LOMR) CASE
NUMBER 17-08-1354P EFFECTIVE FEBRUARY 21, 2019.
2. REFER TO Preliminary Drainage Report for Fox Grove Subdivision Second Filing
DATED FEBRUARY 13, 2019 FOR MORE INFORMATION REGARDING THE
DRAINAGE PLAN.
3. PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY
100-YR BOXELDER CREEK HIGH-RISK FLOOD FRINGE, AND MUST COMPLY
WITH THE FLOODPLAIN REQUIREMENTS OF CHAPTER 10 OF THE CITY OF
FORT COLLINS MUNICIPAL CODE.
4. RESIDENTIAL STRUCTURES ARE ALLOWED IN THE FLOOD FRINGE, PROVIDED
THAT ALL DUCT WORK, HEATING, VENTILATION AND AIR CONDITIONING
SYSTEMS, HOT WATER HEATER, ELECTRICAL AND THE LOWEST FLOOR OF
THE BUILDING ARE A MINIMUM OF 18-INCHES ABOVE THE BASE FLOOD
ELEVATION (BFE). THAT MINIMUM ELEVATION IS KNOWN AS THE
REGULATORY FLOOD PROTECTION ELEVATION (RFPE). RFPE=BFE+18".
5. THE FLOOD FRINGE IS AN AE ZONE, MEANING THAT THE BFE'S HAVE BEEN
DETERMINED.
6. BASEMENTS MAY NOT BE CONSTRUCTED BELOW THE RFPE IN THE FLOOD
FRINGE. CRAWL SPACES (IF USED RATHER THAN SLAB_ON_GRADE) MUST BE
BUILT IN CONFORMANCE WITH SECTION 10_40 OF CITY OF FORT COLLINS
MUNICIPAL CODE (THIS WILL INCLUDE VENTING, SUMP PUMPS, ETC.).
7. ANY AND ALL CONSTRUCTION ACTIVITIES IN THE FLOOD FRINGE MUST BE
PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT.
8. FEMA CROSS-SECTIONS (CSL) ELEVATIONS ARE SHOWN BASED ON THE
NAVD88 DATUM.
9. STORAGE OF EQUIPMENT AND MATERIALS (TEMPORARY OR PERMANENT) IS
NOT ALLOWED IN THE FLOODWAY.
FOR DRAINAGE REVIEW ONLY
NOT FOR CONSTRUCTION
Project Datum: NGVD88
Benchmark #1
Fort Collins Benchmark 25-01: East side of the East frontage road of I-25
approx. 0.5 miles North of Prospect Road on the North end of a head
wall to an irrigation canal.
Elevation: 4921.60
Benchmark #2
Fort Collins Benchmark 26-01: South side of Highway 14 (East Mulberry
St.), approx. 0.4 miles East of the centerline of I-25, on the bridge
parapet wall, on a brass cap stamped "Colo. Dept of Highways". (City of
Fort Collins designation not stamped on cap).
Elevation: 4940.45
Note:If NGVD29 Datum is required for any purpose, the following
equation should be used: NGVD29 = NAVD88 Unadjusted - 3.19'
Basis of Bearings
The Basis of Bearings is the South line of the Northwest Quarter, Section
15, Township 7 North, Range 68 West of the 6th P.M. as bearing North
89°38'50" West.
PROJECT BENCHMARKS:
Pond ID Vol. (Ac-Ft)
100-Yr
WSEL (Ft)
WQ Capture
Vol. (Ac-Ft)
WQ WSEL
(Ft)
Total Req'd
Vol. (Ac-Ft)
100-Yr
Release (cfs)
1 3.70 4921.50 0.12 TBD 3.82 5.10
DESIGN
POINT
BASIN
ID
TOTAL
AREA
(acres)
C2 C100
2-yr
Tc
(min)
100-yr
Tc
(min)
Q2
(cfs)
Q100
(cfs)
1 1 1.12 0.58 0.73 12.2 11.4 1.3 6.1
223.12 0.58 0.73 17.5 16.5 3.2 14.1
3 3 1.09 0.58 0.73 11.8 11.0 1.3 5.9
440.05 0.58 0.73 5.6 5.2 0.1 0.3
5 5 2.82 0.58 0.73 14.1 13.1 3.1 14.2
6 6 2.79 0.58 0.73 17.7 16.7 2.8 12.6
OS1 OS1 1.69 0.33 0.41 16.9 16.1 1.0 4.4
EVCE: 4923.09
A.D. = 1.37
K = 54.85
4926.17
4925.97
4925.80
4925.65
4925.49
4925.33
4925.18
4925.02
4924.86
4924.74
4924.69
4924.63
4924.57
4924.47
4924.38
4924.28
4924.20
4924.11
4924.02
4923.95
4923.92
4923.89
4923.86
4923.82
4920.00
4919.08
4919.14
4919.11
4919.24
4919.40
4919.54
4921.01
4923.89
4924.03
4924.17
30" RCP STORM
STA.=11+51.73
INV.=4918.57 24" RCP STORM
STA.=16+19.32
INV.=4916.88
STA.=18+04.11
TIE TO EXISTING
ASPHALT
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
EXISTING EDGE OF ASPHALT
PROPOSED STORM MANHOLE
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1
4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING
OF 50 FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
X
X
KEYMAP
I-25
FOX GROVE DR
VIXEN DR
R2
8
( IN FEET )
0
1 INCH = 40 FEET
40 40 80 120
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's
R
CENTERLINE
ROLLINS DEN DRIVE
SCALE : 1" = 40' (H) 1" = 5' (V)
NORTH NORTH
R2
CENTERLINE
FOX GROVE DR
SCALE : 1" = 40' (H) 1" = 5' (V)
PROPOSED
STORM DRAIN
PROPOSED
STORM DRAIN
LP STA = 15+20.31
PVI STA = 15+33.24
PVI ELEV = 4924.31
BCVS: 14+90.74
BVCE: 4924.65
ECVS: 15+75.74
EVCE: 4924.95
A.D. = 2.30
K = 36.96
4925.76
4926.01
4926.21
4926.29
4926.28
4926.15
4925.71
4926.02
4925.82
4925.88
4925.94
4926.06
4926.11
4926.16
4926.25
4926.29
4926.30
4926.28
4926.27
4926.25
4926.36
4926.36
4926.26
4926.04
4925.91
4925.81
4925.62
4925.56
4925.49
4925.88
18" RCP STORM
STA.=10+46.80
INV.=4921.21
18" RCP STORM
STA.=15+14.05
INV.=4919.23
STA.=17+00.81
TIE TO EXISTING
ASPHALT
X X X X X
X
BROOK COURT
9' UTILITY EASEMENT
4.5' SIDEWALK
4.5' SIDEWALK
9' UTILITY EASEMENT
9' UTILITY EASEMENT
4.5' SIDEWALK
53'
ROW
30'
-
53'
ROW
30'
-
ROLLINS DEN DRIVE
(SEE SHEET R6)
STA. = 11+80.27
(STREET A)
STA. = 10+00.00
(STREET B)
ROLL OVER CURB
& GUTTER (TYP.)
VIXEN DR
R20' R20' R20'
LOT 7
LOT 14 LOT 15 LOT 16
LOT 17
LOT 24
LOT 20
LOT 21
LOT 22
LOT 8 LOT 38 LOT 39 LOT 40
LOT 23
LOT 5
LOT 18
LOT 41
LOT 12
LOT 10
LOT 9
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
X
X
KEYMAP
I-25
FOX GROVE DR
VIXEN DR
R1
7
( IN FEET )
0
1 INCH = 40 FEET
40 40 80 120
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's
R
CENTERLINE
BROOK COURT
SCALE : 1" = 40' (H) 1" = 5' (V)
EXISTING RIGHT-OF-WAY
LEGEND:
PROPOSED STORM SEWER
EXISTING STORM SEWER
EXISTING EDGE OF ASPHALT
PROPOSED STORM MANHOLE
PROPOSED CURB & GUTTER
PROPOSED CENTERLINE
PEDESTRIAN ACCESS RAMPS
PROPOSED CONCRETE
CROSSPAN (TYP.)
PROPOSED RIGHT-OF-WAY
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND
RECOMMENDATIONS.
3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1
4" BELOW FINISHED GRADE. IF
NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED
WITHIN VEHICLE OR BICYCLE WHEEL PATHS.
4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING
OF 50 FEET.
5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN
THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN
ACCORDANCE WITH CITY STREET REPAIR STANDARDS.
PROPOSED STORM INLET
PROPERTY BOUNDARY
PROPOSED LOT LINE
EASEMENT LINE
SAWCUT LINE
EXISTING LOT LINE
NORTH NORTH
R1
CENTERLINE
VIXEN DR
SCALE : 1" = 40' (H) 1" = 5' (V)
PROPOSED
INLETS
BROOK COURT
PROPOSED
INLETS
30' ELCO
WATERLINE
EASEMENT
6' U.E.
(TYP.)
6' U.E.
(TYP.)
UTILITY
EASEMENT
UTILITY
EASEMENT
ACCESS EASEMENT
REC. NO. 20160050584
30' WATERLINE EASEMENT
TO EAST LARIMER
COUNTY WATER DISTRICT
REC. NO. 20160031252
10' DRY UTILITY EASEMENT
TO CITY OF FORT COLLINS
REC. NO. 20160050584
20' DRAINAGE EASEMENT
TO CITY OF FORT COLLINS
REC. NO. 20160050583
30' UTILITY
EASEMENT
ROLLINS DEN DRIVE
FOX GROVE DR
VIXEN DR
2' GRAVEL
SHOULDERS
3' GRAVEL
SHOULDERS
3' GRAVEL
SHOULDERS
6' GRAVEL
SHOULDER
RAIN GARDEN
FIRE HYDRANT
FIRE HYDRANT
HUNTSMAN DR
10' DRY UTILITY EASEMENT
REC. NO. 20170029883
PROPOSED 8"
SANITARY
PROPOSED 8"
SANITARY
PROPOSED 8"
SANITARY
CONNECT TO EXISTING
SANITARY MANHOLE
CONNECT TO EXISTING
SANITARY MANHOLE
PROPOSED 8"
WATERLINE
PROPOSED 8"
WATERLINE
PROPOSED 8"
WATERLINE
PROPOSED 8"
WATERLINE
TIE TO EXISTING
WATERLINE
X X X
X
X X X X X
X
X X
X
X
X
" W 8" W
8" W 8" W 8" W
8" W
8" W
8" W
8" W
X
X
G
S S
S
S
S
W
S S
S
S
S
W
W
S S S S
W
W
W
W W
W W
S
S S S S
S
W
W
W
W
W
W
W
W
W
W
2' CONCRETE
PAN
EXISTING DETENTION
POND 1
EXISTING DETENTION
POND 2
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
EXISTING STORM DRAIN &
OUTLET STRUCTURE
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
SUNFLOWER SUBDIVISION
(SINGLE FAMILY)
CW SUBTRUST C/O AGUR FOUNDATION
INDUSTRIAL DISTRICT
(UNDEVELOPED)
LOT 1
LEE MLD
(UNDEVELOPED)
FOX GROVE
(SINGLE FAMILY)
PROPOSED 8"
SANITARY
FEMA 100-YR HIGH RISK FRINGE
FEMA 100-YR HIGH RISK FRINGE
OUTLOT A
DRAINAGE AND
ACCESS EASEMENT
LOT 5
LOT 5
LOT 18
LOT 41
OUTLOT C
LOT 3
LOT 7
LOT 14 LOT 15 LOT 16 LOT 17
LOT 24
LOT 20
LOT 21
LOT 22
LOT 27
LOT 25
LOT 38 LOT 39
LOT 36
LOT 35
LOT 37 LOT 42
LOT 43
LOT 44
LOT 32
LOT 28
LOT 31
LOT 33
LOT 47
LOT 34 LOT 45
LOT 29
LOT 4
LOT 6
LOT 8 LOT 40
LOT 30
LOT 2 LOT 1
LOT 23
LOT 26
LOT 46
OUTLOT B
ACCESS EASEMENT
LOT 12
LOT 10
LOT 9
LOT 13
LOT 11
NATURAL HABITAT
BUFFER ZONE
NATURAL HABITAT
BUFFER ZONE
NATURAL HABITAT
BUFFER ZONE
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
OU
6
NORTH
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's
R
EXISTING WATER MAIN
PROPOSED WATER MAIN
PROPOSED STORM SEWER
LEGEND:
W
EXISTING STORM SEWER
EXISTING ELECTRIC METER
EXISTING WATER METER
EXISTING ELECTRIC VAULT
EXISTING POWER POLE
EXISTING GAS METER
EXISTING SANITARY SEWER SS
PROPOSED STORM INLET
PROPOSED CURB & GUTTER
PROPOSED SANITARY SEWER
PROPOSED FIRE HYDRANT
EXISTING FIRE HYDRANT
PROPOSED LOTLINE
EASEMENT LINE
PROPERTY BOUNDARY
1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS
SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO
THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF
SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE
STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR
SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE)
PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS.
2. ALL WATER CONSTRUCTION SHALL BE PER EAST LARIMER COUNTY WATER
DISTRICT'S CONSTRUCTION STANDARDS, LATEST EDITION.
3. ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT'S
CONSTRUCTION STANDARDS, LATEST EDITION.
4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER & WATER MAINS & SERVICES.
5. ALL WATER FITTINGS AND VALVES, EXCLUDING WATER METERS, ARE ONLY
GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
6. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH.
7. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO
STREET CONSTRUCTION.
8. ABBREVIATIONS:
ACC. = ACCESS EASEMENT
E.A.E= EMERGENCY ACCESS EASEMENT
U.E. = UTILITY EASEMENT
D.G.E. = DRAINAGE & GRADING EASEMENT
* = PRIVATE STORM PIPE OR STRUCTURE
9. NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
LANDSCAPING SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE
FLOODWAY.
10. A FLOODPLAIN USE PERMIT IS REQUIRED PRIOR TO PERFORMING ANY WORK
WITHIN THE FEMA 100-YEAR FLOODPLAIN.
11. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONE.
12. THE NATURAL HABITAT BUFFER ZONE IS MEANT TO BE MAINTAINED IN A NATIVE
LANDSCAPE.
NOTES:
S
X
X
KEYMAP
I-25
FOX GROVE DR
VIXEN DR
XXXX
FOX OX GROVE DR
VIXEN DR R
OU
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
ROW
30'
-
6' U.E.
6' U.E. (TYP.)
(TYP.)
6' U.E.
(TYP.)
6' U.E.
(TYP.)
6' U.E.
(TYP.)
5'
D.G.E.
(TYP.)
5' D.G.E.
(TYP.)
6' UE
5'
D.G.E.
(TYP.)
5'
D.G.E.
(TYP.)
5' D.G.E.
(TYP.)
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
9' UTILITY EASEMENT
PROPOSED
STORM DRAIN
PROPOSED
INLETS
CONNECT TO
EXISTING STORM
DRAIN
PROPOSED
STORM DRAIN
PROPOSED
INLETS
BROOK COURT
PROPOSED
INLETS
30' ELCO
WATERLINE
EASEMENT
6' U.E.
(TYP.)
6' U.E.
(TYP.)
UTILITY
EASEMENT
UTILITY
EASEMENT
EXISTING 10' DRY UTILITY EASEMENT
ACCESS EASEMENT
REC. NO. 20160050584
30' WATERLINE EASEMENT
TO EAST LARIMER
COUNTY WATER DISTRICT
REC. NO. 20160031252
10' DRY UTILITY EASEMENT
TO CITY OF FORT COLLINS
REC. NO. 20160050584
20' DRAINAGE EASEMENT
TO CITY OF FORT COLLINS
REC. NO. 20160050583
30' UTILITY
EASEMENT
ROLLINS DEN DRIVE
VIXEN DR
2' GRAVEL
SHOULDERS
3' GRAVEL
SHOULDERS
3' GRAVEL
SHOULDERS
6' GRAVEL
SHOULDER
RAIN GARDEN
EXISTING DETENTION
POND 1
2' CONCRETE
PAN
SUNFLOWER SUBDIVISION
(SINGLE FAMILY)
CW SUBTRUST C/O AGUR FOUNDATION
INDUSTRIAL DISTRICT
(UNDEVELOPED)
LOT 1
LEE MLD
(UNDEVELOPED)
FOX GROVE
(SINGLE FAMILY)
EXISTING DETENTION
POND 1
EXISTING DETENTION
POND 2
OUTLOT B
ACCESS EASEMENT
LOT 5
LOT 5
LOT 18
LOT 41
OUTLOT C
LOT 3
LOT 7
LOT 14
LOT 15 LOT 16
LOT 17
LOT 24
LOT 20 LOT 21
LOT 22
LOT 27
LOT 25
LOT 38 LOT 39
LOT 36
LOT 35
LOT 37 LOT 42
LOT 43
LOT 44
LOT 32
LOT 31 LOT 28
LOT 33
LOT 47
LOT 34 LOT 45
LOT 29
LOT 4
LOT 6
LOT 8 LOT 40
LOT 30
LOT 2 LOT 1
LOT 23
LOT 26
OUTLOT A
DRAINAGE AND
ACCESS EASEMENT
LOT 46
BLOCK 1
4' CONCRETE
TRAIL
FEMA 100-YR HIGH RISK FRINGE
4' CONCRETE
TRAIL
EXISTING 2'
CONCRETE PAN
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
FOX GROVE DR
EXISTING OUTLET
STRUCTURE
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
4' CONCRETE
TRAIL
LOT 12
LOT 10
LOT 9
LOT 13
LOT 11
NATURAL HABITAT
BUFFER ZONE
NATURAL HABITAT
BUFFER ZONE
NATURAL HABITAT
BUFFER ZONE
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
OG
5
NORTH
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's
R
LEGEND:
1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS
SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO
THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF
SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE
STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR
SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE)
PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS.
2. ALL WATER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS
CONSTRUCTION STANDARDS, LATEST EDITION.
3. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN
ALL SANITARY SEWER & WATER MAINS & SERVICES.
4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND
ARE NOT TO SCALE.
5. ROTATE ALL SANITARY MANHOLE LIDS TO LIE OUTSIDE OF THE WHEEL PATH.
6. DRY UTILITY CONDUIT TO BE COORDINATED WITH UTILITY PROVIDERS PRIOR TO
STREET CONSTRUCTION.
7. ABBREVIATIONS:
ACC.= ACCESS EASEMENT
E.A.E= EMERGENCY ACCESS EASEMENT
U.E.= UTILITY EASEMENT
D.G.E.= DRAINAGE & GRADING EASEMENT
8. NO STORAGE OF MATERIALS OR EQUIPMENT SHALL BE ALLOWED IN THE
FLOODWAY, WHETHER TEMPORARY (DURING CONSTRUCTION) OR PERMANENT.
LANDSCAPING SHALL ALSO MEET THE REQUIREMENTS FOR NO RISE IN THE
FLOODWAY.
9. A FLOODPLAIN USE PERMIT AND NO RISE CERTIFICATION IS REQUIRED PRIOR TO
PERFORMING ANY WORK WITHIN THE FLOODWAY (I.E., CURB CUT REMOVAL,
LANDSCAPING).
10. A FLOODPLAIN USE PERMIT IS REQUIRED PRIOR TO PERFORMING ANY WORK
WITHIN THE FEMA 100-YEAR FLOODPLAIN.
11. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONE.
12. THE NATURAL HABITAT BUFFER ZONE IS MEANT TO BE MAINTAINED IN A NATIVE
LANDSCAPE.
NOTES:
EXISTING DECID. TREE
EXISTING CONIF. TREE
EXISTING LIGHT POLE
EXISTING STUMP
EXISTING STORM SEWER LINE ST
EXISTING CURB/GUTTER FLOWLINE
BANK SLOPE
PROPOSED ASPHALT CROSS SLOPE
CONCENTRATED FLOW DIRECTION
PROPOSED SWALE FLOWLINE
PROPOSED OUTFALL CURB/GUTTER FLOWLINE
PROPOSED STORM DRAIN WITH INLET
PROPOSED CONTOUR
EXISTING CONTOUR
PROPOSED FINISH GROUND ELEVATION
EXISTING GROUND ELEVATION
PROPOSED INFLOW CURB/GUTTER FLOWLINE
4950
X
X
KEYMAP
I-25
FOX GROVE DR
VIXEN DR
OG
(UNDEVELOPED)
FEMA 100-YR HIGH RISK FRINGE
FOX GROVE
(SINGLE FAMILY)
EXISTING 8"
CONCRETE WALLS
20' SEWER
EASEMENT PER LEE
MLD NO. 04-S2309
EXISTING 24"
ADS STORM DRAIN
EXISTING 24"
ADS STORM DRAIN
ELEV=4909.76
EXISTING
IRRIGATION DITCH
10' DRY UTILITY EASEMENT
TO CITY OF FORT COLLINS
REC. NO. 20160050584
20' DRAINAGE EASEMENT
TO CITY OF FORT COLLINS
REC. NO. 20160050583
30' WATERLINE EASEMENT TO EAST LARIMER COUNTY
WATER DISTRICT REC. NO. 20160031251 TO BE VACATED
BY THE FOX GROVE SUBDIVISION 2ND FILING PLAT
30' ACCESS EASEMENT REC. NO.
20170029883 TO BE VACATED BY THE FOX
GROVE SUBDIVISION 2ND FILING PLAT
TRAIL TO BE REMOVED
10' DRY UTILITY EASEMENT
REC. NO. 20170029883
DRAINAGE AND UTILITY EASEMENT REC. NO.
20170029883 TO BE VACATED BY THE FOX
GROVE SUBDIVISION 2ND FILING PLAT
UTILITY EASEMENT REC. NO.
20170029883 TO BE VACATED BY THE FOX
GROVE SUBDIVISION 2ND FILING PLAT
UTILITY EASEMENT REC. NO.
20170029883 TO BE VACATED BY THE FOX
GROVE SUBDIVISION 2ND FILING PLAT
TRAIL TO BE REMOVED
±152 LF WATERLINE TO BE RELOCATED
EXISTING TRAIL
ACCESS EASEMENT
NO. 20160050584
EXISTING BARRICADE
TO BE REMOVED
EXISTING BARRICADE
TO BE REMOVED
REMOVE
RIPRAP & FES
EXISTING DETENTION
POND 1
TRAIL TO BE REMOVED
REMOVE EXISTING
FIRE HYDRANT &
REDUCER
EXISTING DETENTION
POND 2
EXISTING STORM PIPE & OUTLET
STRUCTURE TO REMAIN
SAWCUT 103 LF
465 SF STREET
CUT
MILL & OVERLAY
±1286 SQUARE
FEET OF ASPHALT
/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
/ / / / / / / / / / / / / /
REMOVE ±7 LF OF
CURB & GUTTER
REMOVE ±7 LF OF
CURB & GUTTER
/
/ / / / / / / / / / / / / / / / / /
/
/ / / / / / / / /
/
/ / / / / / / / / / / / / / / / / /
/
/ / / / / / / / / / / / / / / / / / / / / / / / / / / /
/
/ / / / / / / / / / / / / / / / / /
/
/ / / / / / / / /
/
/ / / / / / / / / / / / / / / / / /
/
/ / / / / / / / / / / / / / / / / / / / / / / / /
/
/
/
±427 LF WATERLINE TO BE RELOCATED
These drawings are
instruments of service
provided by Northern
Engineering Services, Inc.
and are not to be used for
any type of construction
unless signed and sealed by
a Professional Engineer in
the employ of Northern
Engineering Services, Inc.
NOT FOR CONSTRUCTION
NRN O R T H E
FORT COLLINS: 301 North Howes Street, Suite 100, 80521
GREELEY: 820 8th Street, 80631
970.221.4158
northernengineering.com
EX
4
NORTH
( IN FEET )
0
1 INCH = 50 FEET
50 50 100 150
City Engineer Date
Date
Date
Date
Date
Stormwater Utility
Parks & Recreation
Traffic Engineer
Date
Water & Wastewater Utility
City of Fort Collins, Colorado
UTILITY PLAN APPROVAL
Environmental Planner
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what's
R
EXISTING ELECTRIC E
LEGEND:
G
T
EXISTING STORM SEWER ST
EXISTING TELEPHONE
EXISTING GAS
EXISTING IRRIGATION BOX
EXISTING GAS METER
EXISTING TELEPHONE PEDESTAL
EXISTING TREES (TO REMAIN)
FIELD SURVEY BY:
SUBSURFACE EXPLORATION BY:
NOTES:
1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE
APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL
UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW
CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL
UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN
UNDERGROUND UTILITIES.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL,
REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL.
3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT
MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES
APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE,
ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT
COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL
ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS
RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD
AND CAN BE REACHED AT (970) 482-1249.
4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE.
5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING
SITE SURVEY.
Northern Engineering Services, Inc.
301 N. Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
EXISTING SANITARY SEWER SS
EXISTING WATER W
EXISTING FENCE X
EXISTING WATER METER
EXISTING FIRE HYDRANT
EXISTING ELECTRIC VAULT
PROPERTY BOUNDARY
EXISTING RIGHT-OF-WAY
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
VAULT
ELEC
CONTROL
IRR
EXISTING TREES (TO BE REMOVED)
Earth Engineering Consultants, LLC
Lester L. Litton, PE
4396 Greenfield Drive
Windsor, CO 80550
(970) 545-3908
EEC Project No. 1132018
DATE: April 18, 2013
SAW CUT LINE
MILL & OVERLAY ASPHALT
DEMO LINE / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
X
X
KEYMAP
I-25
FOX GROVE DR
VIXEN DR
XXXX
FOX OX GROVE DR
VIXEN DR R
EX
9. Materials: Plastic Pipe –All gravity sanitary sewer piping shall be Polyvinyl
Chloride (PVC) unless otherwise noted on the approved drawings. Pipe 15”
and smaller shall conform to ASTM D3034, Type PSM, and SDR 35. Pipe 18”
and larger shall conform to ASTM F679. All fittings shall be (PVC) unless
otherwise noted.
10. Pipe Cover: A minimum cover of 3-1/2 feet of cover shall be maintained
throughout the sewer line and service line installation.
11. Bedding: All sewer main installation shall include bedding. Bedding shall be 3
4"
washed rock uniformly graded and compacted. Refer to force main desgin
for force main bedding requirements. Trench shall be excavated to a depth
below established grade equal to ¼ of pipe diameter (min. 4”). Bell
depressions shall be provided for all joints. In event that unstable trench
conditions are encountered at pipeline grade 1-1/2” uniformly graded washed
rock shall be used for stabilization. Bedding material shall be placed and
compacted under and around sides of the pipe. Place bedding in such a
manner as to provide solid, uniform bearing surface for full length of barrel.
Minimum 30” initial lift above pipe before other than hand compaction
equipment is to be used. Note maximum trench width detail.
12. Backfill: Backfilling of trench shall be performed as soon as practical,
subsequent to inspection and approval. Backfilling of acceptable material
shall not be placed in lifts of greater than one (1) foot. Backfill shall be
compacted to 95% of optimum density in roadway and residential areas and
90% in all off-site easement areas unless otherwise noted. Compaction
testing of bedding and back fill shall be at least five tests per 1,000 feet and
at varying depths and locations in accordance with the requirements of the
applicable authority or as required in project specific specifications.
13. Concrete: All concrete construction shall be completed utilizing 3,000 psi at
twenty-eight (28) days or equal concrete.
14. Pavement or Other Repairs: In event that asphalt or concrete pavement,
sidewalks, storm sewers, waterline or any other public or privately owned
property is damaged or requires reconstruction due to the work, repairs or
replacement will be made in accordance with the requirements of the
appropriate governing authority. Private property will be returned to its
original condition or as close to original condition as reasonably possible,
unless otherwise noted on the drawings.
15. Service Taps on Existing Lines: All taps made on existing lines shall be
completed at developer’s expense by District personnel or the District’s
authorized contractor with no exception.
16. Inspection: Construction shall conform to District Standards and
Specifications or project specific specifications at all times. The District shall
inspect the construction as necessary and shall observe all line testing. The
District shall have the authority to ascertain that all construction of facilities is
equal to or better than minimum construction requirements as set forth in
17. Testing: All lines shall be pressure tested and flushed by the Contractor in
accordance with District Standards and Specifications and under the District’s
supervision. Upon passing, copies of all passing test results including soils
compaction in the area of sewer main construction shall be provided to the
District.
18. Acceptance: Upon completion of all utility construction (sewer and other) and
fulfillment of all District requirements, preliminary acceptance of new sewer
system improvements will occur in accordance with District’s acceptance
procedure.
19. Warranty: The Contractor shall warrant the materials, installation,
workmanship and surface restoration for a period of two years from date of
preliminary acceptance. During this warranty period the Developer shall
promptly repair any defects in the work and maintain the work area. At the
close of the two-year warranty period the District will make a field inspection.
Upon satisfactory correction of any deficiencies noted the District would make
final acceptance of the lines and work. The lines and the appurtenances
shall then become the sole property and responsibility of Boxelder Sanitation
District.
20. Drawings of Record and Total Costs: Within 90 days of preliminary
acceptance of the new facilities, the District shall be provided with acceptable
Drawings of Record of the complete system consisting of two sets of fill size
reproduced prints, two sets of ½-size reproduced prints, one set of 6 mil
double matted reproducible mylars and one complete digital file equivalent
(software and version to be confirmed at time of delivery). Written
confirmation of the total cost of all sewer system improvements shall also be
submitted with the Drawings of Record. CS3
3
EAST LARIMER COUNTY WATER DISTRICT
GENERAL NOTES FOR CONSTRUCTION
Version: 10/10/2017
The following information is condensed from the current "Standard Construction
Specifications for Water Mains" (Specification) as adopted by the East Larimer County
Water District (‘ELCO’ or ‘District’) and is to be considered as such. In the event of any
conflict the full District Specification document shall take precedence over these general
notes.
1. Standards and Specifications: Construction shall be per the District
Specifications in effect at the start of construction. Material or equipment shall be
manufactured per the most recent version of applicable industry standards.
2. Locates: Contractor shall coordinate field locates of all existing utilities prior to
commencement of any construction and as required notify all affected utility companies
prior to commencing construction. Cost of repairs to any other utility damaged during
District waterline installation shall be the responsibility of the Contractor.
3. Damage to Property: Contractor shall continuously maintain adequate protection
from damage of all public and private property through which the work is done and shall
be fully responsible for all costs associated with damage to any and all other public and
private property.
4. Safety: Contractor shall comply with any and all requirements and regulations as
set forth by City, County, State and Federal agencies having applicable authority.
5. Landscaping Adjacent to District Waterlines: No landscaping (bushes, shrubs,
trees or other plantings) that has a mature height of over 3 feet (3-ft) shall be placed
within ten feet (10-ft) of any District waterline or appurtenance (distribution main, service
line, fire hydrant, meter, etc.). Bushes or shrubs with a mature height of less than 3-ft
shall be placed a minimum 4-ft from any District waterline or appurtenance. The District
shall have the right to remove any landscaping that violates this standard, at any time
such landscaping is discovered, and shall not be required to replace the removed
landscaping.
6. Design Approval and Construction Start: No construction shall begin without prior
design approval from ELCO. District shall be notified 48 hours in advance of starting
construction or testing to allow for scheduling.
7. Permits: Contractor is responsible for obtaining all County road permits which
may be required. For any permitting where the District must apply for a permit the
Contractor shall coordinate, cover the cost and schedule the permit acquisition with the
District.
8. Changes During Construction: No verbal authorization for field revision shall be
given. All requests for such field revision shall be made in writing accompanied by
proposed change indicated on copy of the approved design drawings. Any field revision
approved and installed shall also be accurately documented on the Contrctor’s As-Built
drawings.
9. Materials of Construction:
a. Pipe: All water piping shall be Polyvinyl Chloride (PVC). All PVC piping 6-inch
through 12-inch shall be DR 18 (pressure class 235 psi) and manufactured in
accordance with AWWA Standard C900, "Polyvinyl Chloride (PVC) Pressure
Pipe, 4-inch through 12-inch, For Water Distribution". All PVC piping 14-inch
through 24-inch shall be DR 18 (pressure class 235 psi) and manufactured in
accordance with AWWA Standard C905, "Polyvinyl Chloride (PVC) Water
Transmission Pipe, Nominal Diameters 14-inch through 36". Pipe with a diameter
greater than 24 inches shall be specified based on engineered design.
b. Tracer Wire: All water piping shall be installed with a twelve (12) gauge solid
copper wire, plastic coated, six hundred (600) volt taped to top of pipe and
surfaced at each valve as a tracer wire.
c. Pipe Joints: Pipe joints shall be made using an integral bell with an elastomeric
gasket push-on type joint or using machined couplings of a sleeve type with
rubber ring gaskets and machined pipe ends to form a push-on type joint.
d. Materials and Installation: All materials installed shall be free of manufacturer
defects. Any defective or damaged materials noted on the construction site shall
be so marked and removed from the site. Under no circumstances shall any PVC
piping be installed utilizing mechanical equipment to seat the joints.
e. Pipe Fittings: All fittings shall be mechanical joint, ductile iron, manufactured in
accordance with AWWA Standard C153. Fittings shall be furnished with a
cement-mortar lining of standard thickness class with a 250 psi pressure rating.
f. Gate Valves: Gate valves shall conform to AWWA Standard C509 with
mechanical joint, 2" open left operating nut and resilient seat.
g. Butterfly Valves: Butterfly valves shall be used for all valves 12-inches and larger
and conform to AWWA Standard C504 with mechanical joint, 2" open left
operating nut, resilient seat and shall be equipped with sand bonnet.
h. Fire Hydrants: Hydrants shall conform to AWWA Standard C502, 1" square
open-right operating nut. Allowable manufacturers and models are Mueller Super
Centurion with epoxy coated shoe or American Flo Control Waterous Pacer WB67-250X
with epoxy coated shoe. All fittings shall be swing assemblies with anchor couplings.
i. Pipe, Valve and Fitting Wrap: All fittings, valves, fire hydrant shoes and plugs
shall be poly-wrapped with 8-mil thick polyethylene plastic wrap, double layered,
and ends securely taped prior to backfill.
10. Bedding: All pipe shall be bedded in 3/4" washed rock uniformly graded and
compacted. Trench shall be excavated to a depth below established grade equal to 1/4
of pipe diameter (min. 4"). Bell depressions shall be provided for all joints. In event that
unstable trench conditions are encountered at pipeline grade 1-1/2" uniformly graded
washed rock shall be used for stabilization. Bedding material shall be placed and
compacted under and around sides of the pipe. Minimum 30" backfill above pipe before
other than hand compaction equipment is to be used. Note maximum trench width detail.
11. Backfill: Backfill of acceptable material shall be placed in lifts not greater than
one (1) foot. Backfill shall be compacted to 95% of optimum density in roadway areas or
per road authority’s requirements, and 90% in all other locations. Compaction testing of
bedding and backfill shall be at least five tests per 1,000 feet and at varying depths and
locations in accordance with the requirements of the applicable authority.
12. Joint Restraint: All fittings, tees, plugs and fire hydrants shall be provided with
anchor couplings and/or joint restraint in accordance with District Specifications or as
required per engineer’s design. Thrust blocks shall be used only as required per field
conditions and as approved or directed by the District field inspector.
13. Concrete: All concrete construction, including thrust blocks, shall be completed
utilizing Type 5 or equal cement only.
14. Asphalt Replacement: For asphalt pavement that is cut and has been in place
less than two years (according to City or County Engineer's record), the cut shall be a
minimum of 20 feet in width and will be replaced to the specified depth by a paving
machine.
15. Pipe Cover: A minimum cover of 4-1/2 feet of cover over top of pipe shall be
maintained throughout the waterline and service line installation, particularly in areas of
new grading and drainage swales. Extra bury depth may be required to maintain
minimum cover at drainage culvert crossings and/or fire hydrant runs. Maximum
allowable cover shall be 6 feet, unless specifically approved by the District.
16. Connection to Existing System: All connections to existing waterlines shall be
completed at developer's expense by District personnel or the District's authorized
contractor with no exception.
17. Inspection: The District shall have the authority to inspect and verify that all
construction of facilities is equal to or better than minimum construction requirements as
set forth in the District’s Specifications. The District shall also have the authority to
assign an inspector to check any and all work, including all materials to be incorporated
in the work, excavation, bedding, backfill, testing and all construction methods and
practices.
18. Testing and Acceptance: All lines shall be pressure tested, chlorinated and
flushed by the Contractor in accordance with District Specifications and under the
District's supervision. Upon passing chlorination testing, bacteriological testing will be
completed by a State certified water quality control laboratory. Copies of all passing test
results, including soils compaction in the area of water main construction, shall be
provided to the District.
19. Project As-Built and Record Drawing Requirements:
a. As-built drawings are prepared by the contractor. They confirm, in red ink, on-site
changes to the original construction documents. The As-built drawings shall be
delivered to the project’s design engineer for conversion to Record Drawings. A
PDF version shall be delivered to the District.
b. Record Drawings are prepared by the project’s design engineer and reflect onsite
changes the contractor noted in the As-built drawings. The Record Drawings
shall be approved by the District prior to Preliminary Acceptance of the project.
Record Drawings are to be delivered to the District in hard copy (11 x 17 format)
and electronic format. Hard copy drawing text font size shall be large enough to
be legible with font size approved by the District. Electronic format shall be
delivered in Adobe (PDF), AutoCAD and ArcView shape files (release version to
be confirmed with District at time of submittal). These documents shall accurately
reflect any change made in the field which varies from the approved construction
plan and including, at a minimum, field dimensions and elevations, horizontal and
vertical locations of underground utilities and appurtenances. Include with the
Record Drawings a complete copy of the recorded Filing Plat and a written
confirmation of total costs of all water system improvements involved.
20. Warranty: The Contractor shall warrant all work associated with the waterline
installation including, but not limited to the materials, installation workmanship and
surface restoration for a period of two years from date of Preliminary Acceptance. During
this warranty period the Contractor shall repair any defects in the work and maintain the
work area. At the close of the two-year warranty period and upon satisfactory correction
of any deficiencies noted, the District shall accept the constructed lines and
appurtenances as the sole property and responsibility of the District.
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release
of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least
two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement.
18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether
resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins
failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development.
19. All recommendations of the Preliminary Drainage Report for Fox Grove Subdivision Second Filing dated FEBRUARY 13, 2019, by Northern Engineering
Services, Inc., shall be followed and implemented.
20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in
good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping.
21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be
removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of
Fort Collins street inspector.
22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is
obtained, if applicable.
23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer
shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at
least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is
not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City
of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation.
24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and
prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original
geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins'
default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional
Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb,
gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report.
25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all
intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort
Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of
Fort Collins before installation of base course or asphalt will be allowed on the streets.
26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes
of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and
marked so as to reduce the excavation necessary for building connections.
27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within
these districts.
28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire
Hazard Area Mitigation Regulations in force at the time of final plat approval.
29. Prior to the commencement of any construction, the contractor shall contact the City of Fort Collins Forester to schedule a site inspection for any tree removal
requiring a permit.
30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to
OSHA Publication 2226, Excavating and Trenching.
31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort
Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible
for providing any and all traffic control devices as may be required by the construction activities.
32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations
Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor
will be charged for the labor, materials and equipment to reinstall the sign as needed.
33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street
operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development.
34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities
on Sundays or holidays, unless there is prior written approval by Larimer County.
35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or
designated to be provided, installed, or constructed, unless specifically noted otherwise.
36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification,
and annotate the dimension on the as-built record drawings.
37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a
copy of any permits and extension agreements needed for the job.
38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the
Developer shall contact the Designer and the City of Fort Collins Engineer immediately.
39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer
County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer.
40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis
of bearings. The information shall be as follows:
Project Datum: NGVD88
Benchmark #1
Fort Collins Benchmark 25-01: East side of the East frontage road of I-25 approx. 0.5 miles North of Prospect Road on the North end of a head wall to an irrigation
canal.
Elevation: 4921.60
Benchmark #2
Fort Collins Benchmark 26-01: South side of Highway 14 (East Mulberry St.), approx. 0.4 miles East of the centerline of I-25, on the bridge parapet wall, on a
brass cap stamped "Colo. Dept of Highways". (City of Fort Collins designation not stamped on cap).
Elevation: 4940.45
Note:If NGVD29 Datum is required for any purpose, the following equation should be used: NGVD29 = NAVD88 Unadjusted - 3.19'
Basis of Bearings
The Basis of Bearings is the South line of the Northwest Quarter, Section 15, Township 7 North, Range 68 West of the 6th P.M. as bearing North 89°38'50" West.
41. All stationing is based on centerline of roadways unless otherwise noted.
42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping,
structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's
expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of
Occupancy.
43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the
City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an
asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required.
The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts
are made.
44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the
grades and condition as required by these plans.
45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections.
46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship
defects for a minimum period of two years from the date of acceptance.
47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and
pipes, for the following private streets: N.A.
48. Approved Variances are listed as follows: N.A.
CONSTRUCTION NOTES
A. Grading and Erosion Control Notes
1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site.
2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required
erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction
plans, and erosion control report.
4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently
watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown
herein.
5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s)
required for immediate construction operations, and for the shortest practical period of time.
6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping
or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street
rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g.
seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County.
7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall:
a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to
ensure the continued performance of their intended function.
b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector.
c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector.
8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all
drainage infrastructure and other public facilities.
9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and
make sure streets and walkways are cleaned at the end of each working day.
10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their
release into any waters of the United States.
11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and
perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched.
12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning
the maintenance over to the City/County or Homeowners Association (HOA).
13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or
contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and
gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and
disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations.
14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located
at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed
and properly disposed of prior to the area being restored.
15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever
measures are determined necessary, as directed by the City.
B. Street Improvement Notes
1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here.
2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to
any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for
approval prior to placement of any asphalt.
3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a
clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel
cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins.
4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has
been inspected and approved by the City of Fort Collins Engineer.
5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not
allowed.
6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street
condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25,
Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made
by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt
overlay work.
7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the
Right-of-Way Work Permit traffic control plan.
8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters
that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly.
9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth
section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire
subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at
least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the
subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced
or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All
"proof rolls" shall be preformed in the presence of an Inspector.
C. Traffic Signing and Pavement Marking Construction Notes
1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes
listed here.
2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic.
3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD.
4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads.
5. All lane lines for concrete pavement should be epoxy paint.
6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the
same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols.
7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards.
8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction.
9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings.
10. All sign posts shall utilize break-away assemblies and fasteners per the Standards.
11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the
field inspection must be corrected before the 2-year warranty period will begin.
12. The Developer installing signs shall be responsible for locating and protecting all underground utilities.
13. Special care shall be taken in sign location to ensure an unobstructed view of each sign.
14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins
Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen
condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the
2-year warranty period for new construction (except fair wear on traffic markings).
15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail.
D. Storm Drainage Notes
1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage
facilities shall be the responsibility of the property owner(s).
2. All recommendations of the Preliminary Drainage Report for Fox Grove Subdivision Second Filing dated FEBRUARY 13, 2019 by Northern Engineering
Services, Inc., shall be followed and implemented.
3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and
approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release
of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least
two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement.
CS2
2
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT
conditions that I have noted on
these plans.
These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility
by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness
of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities
required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort
Collins for additional quantities of items shown that may be required during the construction phase.
DISCLAIMER STATEMENT:
CERTIFICATION STATEMENT:
VICINITY MAP
NORTH
Project Datum: NGVD88
Benchmark #1
Fort Collins Benchmark 25-01: East side of the East frontage road of I-25 approx. 0.5 miles
North of Prospect Road on the North end of a head wall to an irrigation canal.
Elevation: 4921.60
Benchmark #2
Fort Collins Benchmark 26-01: South side of Highway 14 (East Mulberry St.), approx. 0.4 miles
East of the centerline of I-25, on the bridge parapet wall, on a brass cap stamped "Colo. Dept
of Highways". (City of Fort Collins designation not stamped on cap).
Elevation: 4940.45
Note:If NGVD29 Datum is required for any purpose, the following equation should be used:
NGVD29 = NAVD88 Unadjusted - 3.19'
Basis of Bearings
The Basis of Bearings is the South line of the Northwest Quarter, Section 15, Township 7 North,
Range 68 West of the 6th P.M. as bearing North 89°38'50" West.
Northern Engineering Services, Inc.
301 N. Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
ORIGINAL FIELD SURVEY BY:
Earth Engineering Consultants, LLC
Lester L. Litton, PE
4396 Greenfield Drive
Windsor, CO 80550
(970) 545-3908
SUBSURFACE EXPLORATION BY:
PROJECT BENCHMARKS:
BEING A REPLAT OF TRACT A, FOX GROVE SUBDIVISION, LOCATED IN THE NORTHWEST 1
4 OF SECTION
15, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS,
COUNTY OF LARIMER, STATE OF COLORADO
SHEET INDEX
GAS-----------------Xcel Energy-------------------------------Stephanie Rich (970) 225-7828
ELECTRIC-------- City of Fort Collins Light & Power---Jim Spaulding (970) 416-2772
CABLE------------- Comcast-----------------------------------Don Kapperman (970) 567-0425
TELECOM.--------CenturyLink-------------------------------Robert Rulli (970) 490-7503
WATER------------ East Larimer County Water District-Randy Siddens (970) 493-2044
WASTEWATER--Boxelder Sanitation District-----------Brian Zick (970) 498-0604
STORMWATER- City of Fort Collins Utilities------------Shane Boyle (970) 221-6339
FOX GROVE SUBDIVISION SECOND FILING
Earth Engineering Consultants, LLC
Lester L. Litton, PE
4396 Greenfield Drive
Windsor, CO 80550
(970) 545-3908
Ripley Design Inc.
Klara Rossouw
419 Canyon Avenue Ste 200
Fort Collins, CO 80521
(970) 224-5824
Imago Enterprises Inc.
Lester Kaplan
140 Palmer Drive
Fort Collins, CO 80525
(970) 226-6819
ELB Engineering, LLC
Eric L. Bracke, P.E., P.T.O.E.
5401 Taylor Lane
Fort Collins, CO 80528
(970) 688-7551
Northern Engineering Services, Inc.
Bob Tessely, PLS
301 N. Howes Street, Suite 100
Fort Collins, Colorado 80521
(970) 221-4158
NRN O R T H E
UTILITY PLAN REVIEW
EAST LARIMER COUNTY WATER DISTRICT
1 CS1 COVER SHEET
2-3 CS2-CS3 GENERAL & CONSTRUCTION NOTES
4 EX EXISTING CONDITIONS & DEMOLITION PLAN
GRADING SHEETS
5 OG OVERALL GRADING PLAN
UTILITY SHEETS
6 OU OVERALL UTILITY PLAN
ROAD SHEETS
7 R1 BROOK COURT & VIXEN DR
PLAN & PROFILE
8 R2 ROLLINS DEN DRIVE & FOX GROVE DR
PLAN & PROFILE
DRAINAGE PLAN SHEETS
9 DR1 DRAINAGE EXHIBIT
CS1
1
PROJECT
LOCATION
UTILITY PLAN REVIEW
BOXELDER SANITATION DISTRICT