Loading...
HomeMy WebLinkAbout614 LESSER DRIVE CARRIAGE HOUSE - FDP190013 - SUBMITTAL DOCUMENTS - ROUND 1 - ARCHITECTURAL DETAILSEP EM REF GM DW REF. W D GM GM EM EP REF REF GM REF. DW W/D EP EM FLOOR PLAN NOTES DIMENSIONS ARE TO FACE OF STRUCTURAL ELEMENT (STUDS, CONCRETE WALLS, ETC.) EXCEPT TO CENTERLINE OF POSTS AND COLUMNS, U.N.O. DOOR AND WINDOW SIZES ARE UNIT DIMENSIONS. ROUGH OPENINGS WILL VARY DEPENDENT ON FINAL MANUFACTURER. VERIFY ROUGH OPENING SIZES WITH MANUFACTURER. WALL FRAMING TO BE @16" O/C HEM FIR #2 U.N.O. NEW WALL-2x6 NEW WALL-2x4 U.N.O. WALL TO REMAIN WALL TO BE REMOVED 2F AREA WITH CEILING HEIGHT ≥7'-6" ELECTRICAL PANEL ELECTRIC METER FRAMING: WINDOW TAG LEGEND: DOOR TAG LEGEND: E=EXIST. OPG. DOOR HARDWARE- SEE HARDWARE SCHEDULE FOR QTY'S DOOR STYLE- SEE STYLE LEGEND WIDTH x HEIGHT C-DB 2484 E EGRESS E=EXIST. OPG. (W+H) EW=EXIST. OPG. WIDTH UNIT MATERIAL: W=WOOD F=FIBERGLASS V=VINYL WIDTH x HEIGHT T=TEMPERED OPERATION: AW=AWNING SL=SLIDER SH=HUNG DH=DBL HUNG SC=CASEMENT DC=DBL CASEMENT FX=FIXED MU= MULLED UNIT W-SL EGR EW 2448T FAU BED 2 BATH V-SH 3036 V-SH 2654T V-SH 2654T EW V-SH 2436T V-SH 2654T V-SH 2654T EGR V-SH 3660 V-SH 2660 C 3080 B-KD 3080 V-SH 2660 5'-9" 4'-0" 22'-7 1/2" 8'-4 1/2" 14'-3" 3'-0" 2'-1" 8'-4 1/2" 14'-3" 5'-0" 3'-4 1/2" 2'-1" 2'-4" 19'-9" EQ 6'-8" 3'-1" 3'-1" 6'-8" EQ 8'-2 1/2" 8'-2 1/2" 2'-2" BED 1 4'-10" 2'-1" B-KD 3680 A-DM 4878 C 3680 A-PA 3280 A-PA 3080 A-PA 3080 A-DM 4880 A-DM 4880 EGR V-SH 3660 H@6'-10" H@6'-10" H@6'-10" H@MATCH(E) H@MATCH(E) H@6'-10" H@MATCH(E) H@MATCH(E) H@MATCH(E) H@6'-8" MUDROOM H@6'-10" H@6'-8" V-SH 2436T V-SH 2436T 4'-0" A-PR 3080 4'-0" C 3080 UP 2R UP 2R 10'-6" 15'-0" 1 A4.0 1 A4.0 25'-6" 6'-0" 20'-0" 26'-0" 2 A4.0 4'-4 1/2" 2'-4 1/2" 3'-4 1/2" 3'-5 1/2" 3'-6 1/2" 2'-10 1/2" 3'-10" 4'-0 1/2" 6'-5 1/2" 5'-4 1/2" 5'-5" 4'-2 1/2" 1'-9" 5'-3 1/2" 4'-6" 4'-6" 11'-8 1/2" 26'-0" 1'-9" 15'-0" 4.01 8.01 B-KD 3680 H@6'-10" H@6'-10" B-DM 3666 D-KY 3080 A-PA 2480 C 3080 C 3080 C 3680 C 2980 B-DM 2480 B-KD 3080 9690 V-SC 3042 V-SC 3042 V-AW 3030 V-AW 3030 V-AW 3030 V-AW 3236 B-KD 3080 V-FX 4227 H@5'-8" H@6'-10" H@6'-10" H@6'-10" H@6'-10" R @ T @ 2 4 1/2" 1 11" R @ T @ 14 7 5/8" 13 10" 4.01 (+1" NOSING) UP 1'-1" 7'-6" 7'-6" UP 2R UP UP 2R 4'-0" 3'-0" 8'-0" 8.18 9'-6" 13'-0" 3'-6" 1 A4.0 1 A4.0 2 A4.0 26'-0" 3'-9" 12'-0" 26'-0" 15'-9" 10'-3 1/2" 6'-0 1/2" 2'-4 1/2" 5'-3 1/2" 15'-0" EQ EQ 8'-8" 4'-4" 20'-3 1/2" 3'-10" 11'-2" 3'-1" 3'-8" 7'-6" A-PR 3080 A-PR 3080 A-PR 3080 A-PA 4880 A-PA 2480 EGR V-SC 3260 EGR V-SC 3260 V-AW 3018T V-AW 3018T V-FX 4218 H@5'-8" H@7'-0" H@7'-0" H@5'-4" H@5'-4" 10.01 10.01 DN 429 S. HOWES STREET FORT COLLINS, CO 80521 970.472.8100 DRAWN: INITIAL PREPARATION: 1" SCALE CURRENT PREPARATION: 614 LESSER DRIVE CARRIAGE HOUSE 614 LESSER DRIVE, FORT COLLINS, 80524 A2.0 05/16/2019 PDP/FDP FORMAL SUBMITTAL ROUND 1 EXISTING, DEMO, NEW PLANS MH 06/25/2019 KEYNOTES 4.01 CRAWL ACCESS HATCH LARGE ENOUGH TO REMOVE FAU. CREATE MIN. 30"Hx22"W PATHWAY TO EQUIPMENT @ CRAWL SPACE, W/30" DEEP x30" WIDE CLEAR SERVICE SPACE. 8.01 RAISE PLATFORM FOR WATER HEATER AS REQ'D SO THAT IGNITION SOURCE IS NOT LESS THAN 18 INCHES ABOVE GARAGE FLOOR. 8.18 FLOOR MOUNTED SUPPLY 10.01 SPRAY FOAM THIS WALL 1/4" = 1'-0" 1' 5' 10' EXISTING PLAN 1/4" = 1'-0" 1' 5' 10' NEW EXISTING HOUSE PLAN 1/4" = 1'-0" 1' 5' 10' DEMO PLAN 1/4" = 1'-0" 1' 5' 10' NEW CARRIAGE HOUSE 1F PLAN 1/4" = 1'-0" 1' 5' 10' NEW CARRIAGE HOUSE 2F PLAN