HomeMy WebLinkAboutCOUNTRY CLUB RESERVE - FDP180030 - SUBMITTAL DOCUMENTS - ROUND 3 - SITE PLAN4" W
4" W
4" W 4" W 4" W 4" W 4" W 4" W
4" W
4" W 4" W
V.P.
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
V.P.
V.P.
A.R.V.
GAS
GAS
V.P. V.P.
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
E
E
E
E
E E E
E
E
E E
E
E
4" W 4" W
4" W
4" W 4" W 4" W 4" W
4" W
4" W 4" W 4" W 4" W 4" W 4" W
4" W
W
W W
W
W
W W
W W W
W
W
W W
W W
W W W W
W
W W W
V
.P.
V.P.
V.P.
A.R.V.
GAS
X X
X
X
X X
G
G
G
G G
G
G
G G
E
E
E
E E
E
E E E E E
E E E
E
E E E E
WV
WV
X
X
X X
X
X X X X X X
X X
X
M
X
X
X
X X
X
4" W
4" W 4" W 4" W 4" W
4" W
4" W 4" W 4" W 4" W 4" W 4" W
4" W
4" W 4" W 4" W 4" W
4" W
W
W
W W
W
W W W
W
W
E E
E E E
E E E
E
E
X
X
X
X X
F
E
S
M
F
E
S
T
ELE
X
X
X
10" W 10" W
10" W
10" W
10" W
10" W 10" W
10" W
10" W
10" W
10" W 10" W
10" W
10" W
10" W
10" W 10" W
B
B
W
W
W
W
LOD LOD
LOD
LOD
LOD
LOD
LOD LOD
4" W
4" W 4" W 4" W 4" W 4" W 4" W
4" W
4" W 4" W 4" W 4" W
4" W
4" W
V.P.
WV
WV
WV
WV
WV
WV
F
E
S
M
F
E
S
X X X
X X X X X X X X
X
W
S
O
X
X
V.P.
VAULT
CABLE
BOX
CABLE
H2O
X
10" W
10" W
10" W
10" W
10" W 10" W
10" W
10" W
10" W
10" W 10" W
10" W
10" W
10" W
W W
W
W
W
OHE
OHE
OHE
OHE
OHE OHE OHE
ST
B
W
W
W
W
W
W
W
W
W W W
W W
W
W
W
W
W
W W
W W W
W
W
W W W W W
GAS
X
X
V.P.
V.P.
X X
X
X X
G
G G
G
G
G
G G G G
G
G
G
G
G
G G
G G
G
G G
G
G G G G G
E E E
E
E
E
E
E
E
E
E
E E
E E
E E
E
E E
E
E
E
W
W
W W W
W W
W W
W W
W W
W W
W
W W
W
W
G G G
G
G G
G G G G G G G
G G
G
G G G
E
E
E E
E
E
E
E
E
E
E E
E E
E E E
E
E
E
E
X
X X
B
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD
LOD
U
D
UD
UD UD UD
UD
SD
SD SD
W W
W
W W
W
W
W
W
X X
X X
X X X
G
G G
G G
G
G
G
G
G
E
E E
E
E E
E E E
X
X
X
X X
X
X
X
X
X X
X
X
X
V
.P.
X
X
X
X
X
OHE OHE OHE OHE OHE
B
ST
ST ST ST
W
W
W W W W W W
W
W
W
W W W W
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
UD
15" SS 15" SS 15" SS 15" SS 15" SS 15" SS
15" SS
15" SS
15" SS 15" SS
15" SS 15" SS
SD
SD
SD
SD
SD
SD
SD SD
SD
SD SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
14" W 14" W 14" W 14" W 14" W
14" W 14" W
14" W 14" W
14" W 14" W
4" W 4" W
4" W
4" W 4" W
V
.P.
W
W
W
W
W
W
W
W
W
W
V.P.
V.P.
A.R.V.
GAS
GAS
V.P.
X
G
G G
G
G
G
G
E
E
E
E
E
E
E
E
E
W
V
WV
WV
WV
WV
WV
X
V.P.
WV
WV
X
X
X X
M
X
F
E
S
M M
F
E
S
F
E
S
M
TELE
F.O.
TELE
F
E
S
MGAS
F
E
S
M
F
E
S
TELE
F
E
S
M
F
E
S
X
W
S
O
V.P.
VAULT
CABLE
BOX
CABLE
H2O
V.GAS P.
GAS
10" W
10" W 10" W
10" W
10" W
OHE
OHE
B
B
B
B
B
B
B
B
A.V.
AW
W W
W
E
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
12" W 12" W
12" W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
W
W
W
S
S
S
S
S
S S
S
S
S
S
S
S
W W
W
W
W
W
W
W
W
S
S
S
S S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S S
W
W
W
W
W W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S S
S
W W
W W W
W
W
W
W
W
S
S
S S
S
S SSS
S
S
S
S
S W W
W W W
W
W W
W
W
W W
W
W W
W
W
W W
W
W W W
W
W W W
W
W W
S S S
S S
S S
S S S S
S
S S S S
S S
S S S
S
W S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
S
S
14" W 14" W
W
A.V.
A.V.
W
W
LOD
LOD
OF:
SHEET NUMBER:
FORT COLLINS, CO 80524
COUNTRY CLUB
RESERVE
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Berthoud,CO 80513
T
B
970.532.5891
TBGroup.us
PREPARED FOR
REVISIONS
SHEET INFORMATION
DATE
SEAL
7
PROJECT TITLE
SHEET TITLE
ISSUE DATE
HILLSIDE COMMERCIAL
GROUP, LLC
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
MAY 29, 2019
FINAL
DEVELOPMENT
PLAN
1st Submittal 12/12/18
2nd Submittal 3/13/19
3rd Submittal 5/29/19
Site Plan
SCALE 1" = 50'-0" S 6.0
0 50' 75' 100' NORTH
MATCH LINE - SHEET 3
MATCH LINE - SHEET 5
350' SETBACK
OIL/GAS (TYP.)
OIL/GAS
WELL HEAD #4
LIMIT OF WORK
OIL/GAS
WELL HEAD #3
LIMIT OF WORK
350' SETBACK
OIL/GAS (TYP.)
TURNBERRY RD.
Site Plan
EXISTING CONTOURS
EASEMENT LINE
PROPERTY LINE
Legend
Site Plan Notes
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED
AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES,
UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS,
TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH
THESE PLANS.
5. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE
CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE
UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.
6. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY
PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE
CITY.
7. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE
EXTINGUISHING SYSTEM.
8. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND
DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO
MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND
WITH NO MORE THAN 1:48 CROSS SLOPE.
9. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO
COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS' ASSOCIATION. THE PROPERTY
OWNERS' ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON
OPEN SPACE AREAS.
10. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND
GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO
CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS
AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
11. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER
APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS
TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL
BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE
ADEQUATE VISIBILITY.
12. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE
AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT
SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR
APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR
OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.
PROPOSED CONTOURS
BUILDING ENVELOPE
2 3
5 6
1
4
Key Map
5' MOWN SOFT
SURFACE TRAIL
(TYP.)
5' MOWN SOFT
SURFACE TRAIL
(TYP.)
THE NATURAL HAIBTAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONE.
R350'
R350'
STREET LIGHT
(TYP.)
SD
SD
SD
SD SD
SD
SD SD
SD
SD
SD
SD SD
SD
SD SD
SD
SD SD SD
SD
SD
SD
SD
SD
SD
SD SD
SD SD SD
SD
SD
SD SD
SD
SD
SD
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
W
W
W
W
S
S
S
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
W
W
4" W 4" W
4" W
4" W 4" W
V.P.
W
W
W
W
W
W
W
W
W
W
V.P.
V.P.
A.R.V.
GAS
GAS
V.P.
X
G
G G
G
G
G
G
E
E
E
E
E
E
E
E
E
W
V
WV
WV
WV
WV
WV
X
V.P.
WV
WV
X
X
X X
M
X
F
E
S
M M
F
E
S
F
E
S
M
TELE
F.O.
TELE
F
E
S
MGAS
F
E
S
M
F
E
S
TELE
F
E
S
M
F
E
S
X
W
S
O
V.P.
VAULT
CABLE
BOX
CABLE
H2O
V.GAS P.
GAS
10" W
10" W 10" W
10" W
10" W
OHE
OHE
B
B
B
B
B
B
B
B
A.V.
AW
W W
W
E
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
12" W 12" W
12" W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
W
W
W
S
S
S
S
S
S S
S
S
S
S
S
S
W W
W
W
W
W
W
W
W
S
S
S
S S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S S
W
W
W
W
W W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S S
S
W W
W W W
W
W
W
W
W
S
S
S S
S
S SSS
S
S
S
S
S W W
W W W
W
W W
W
W
W W
W
W W
W
W
W W
W
W W W
W
W W W
W
W W
S S S
S S
S S
S S S S
S
S S S S
S S
S S S
S
W S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
S
S
14" W 14" W
W
A.V.
A.V.
W
W
LOD
LOD
OF:
SHEET NUMBER:
FORT COLLINS, CO 80524
COUNTRY CLUB
RESERVE
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Berthoud,CO 80513
T
B
970.532.5891
TBGroup.us
PREPARED FOR
REVISIONS
SHEET INFORMATION
DATE
SEAL
7
PROJECT TITLE
SHEET TITLE
ISSUE DATE
HILLSIDE COMMERCIAL
GROUP, LLC
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
MAY 29, 2019
FINAL
DEVELOPMENT
PLAN
1st Submittal 12/12/18
2nd Submittal 3/13/19
3rd Submittal 5/29/19
Site Plan
SCALE 1" = 50'-0" S 5.0
0 50' 75' 100' NORTH
MATCH LINE - SHEET 6
MATCH LINE - SHEET 2
MATCH LINE - SHEET 4
BALTUSROL DR.
CARNOUSTIE DR.
ROYAL TROON AVE.
LIMIT OF WORK
350' SETBACK
OIL/GAS (TYP.)
350' SETBACK
OIL/GAS (TYP.)
350' SETBACK
OIL/GAS (TYP.)
Site Plan
5' MOWN SOFT
SURFACE TRAIL
(TYP.)
EXISTING CONTOURS
EASEMENT LINE
PROPERTY LINE
Legend
Site Plan Notes
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED
AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES,
UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS,
TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH
THESE PLANS.
5. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE
CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE
UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.
6. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY
PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE
CITY.
7. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE
EXTINGUISHING SYSTEM.
8. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND
DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO
MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND
WITH NO MORE THAN 1:48 CROSS SLOPE.
9. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO
COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS' ASSOCIATION. THE PROPERTY
OWNERS' ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON
OPEN SPACE AREAS.
10. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND
GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO
CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS
AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
11. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER
APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS
TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL
BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE
ADEQUATE VISIBILITY.
12. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE
AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT
SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR
APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR
OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.
PROPOSED CONTOURS
BUILDING ENVELOPE
2 3
5 6
1
4
Key Map
THE NATURAL HAIBTAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONE.
STREET LIGHT
(TYP.)
E
E E
E
E
E
X X
X X
X
X X
X X
X
X
X
X
X X X X X X X X
X
X
X X
X X
X
X X
B
B
A.V.
W
W W
W
E
E E E E
E
E E
E
LOD
LOD LOD
LOD
LOD LOD LOD LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
S
S
S
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
W S
W
S
S
W
A.V.
4" W 4" W
4" W
4" W 4" W
V
.P.
W
W
W
W
W
W
W
W
W
W
V.P.
V.P.
A.R.V.
GAS
GAS
V.P.
X
G
G G
G
G
G
G
E
E
E
E
E
E
E
E
E
W
V
WV
WV
WV
WV
WV
X
V.P.
WV
WV
X
X
X X
M
X
F
E
S
M M
F
E
S
F
E
S
M
TELE
F.O.
TELE
F
E
S
MGAS
F
E
S
M
F
E
S
TELE
F
E
S
M
F
E
S
X
W
S
O
V.P.
VAULT
CABLE
BOX
CABLE
H2O
V.GAS P.
GAS
10" W
10" W 10" W
10" W
10" W
OHE
OHE
B
B
B
B
B
B
B
B
A.V.
AW
W W
W
E
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
12" W 12" W
12" W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
W
W
W
S
S
S
S
S
S S
S
S
S
S
S
S
W W
W
W
W
W
W
W
W
S
S
S
S S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S S
W
W
W
W
W W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S S
S
W W
W W W
W
W
W
W
W
S
S
S S
S
S SSS
S
S
S
S
S W W
W W W
W
W W
W
W
W W
W
W W
W
W
W W
W
W W W
W
W W W
W
W W
S S S
S S
S S
S S S S
S
S S S S
S S
S S S
S
W S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
S
S
14" W 14" W
W
A.V.
A.V.
W
W
LOD
LOD
OF:
SHEET NUMBER:
FORT COLLINS, CO 80524
COUNTRY CLUB
RESERVE
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Berthoud,CO 80513
T
B
970.532.5891
TBGroup.us
PREPARED FOR
REVISIONS
SHEET INFORMATION
DATE
SEAL
7
PROJECT TITLE
SHEET TITLE
ISSUE DATE
HILLSIDE COMMERCIAL
GROUP, LLC
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
MAY 29, 2019
FINAL
DEVELOPMENT
PLAN
1st Submittal 12/12/18
2nd Submittal 3/13/19
3rd Submittal 5/29/19
Site Plan
SCALE 1" = 50'-0" S 4.0
0 50' 75' 100' NORTH
MATCH LINE - SHEET 5
MATCH LINE - SHEET 1
BALTUSROL DR.
BALTUSROL CT.
350' SETBACK
OIL/GAS (TYP.)
OIL/GAS
WELL HEAD #2
350' SETBACK
OIL/GAS (TYP.)
LIMIT OF WORK
LIMIT OF WORK
Site Plan
5' MOWN SOFT
SURFACE TRAIL
(TYP.)
EXISTING CONTOURS
EASEMENT LINE
PROPERTY LINE
Legend
Site Plan Notes
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED
AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES,
UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS,
TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH
THESE PLANS.
5. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE
CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE
UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.
6. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY
PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE
CITY.
7. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE
EXTINGUISHING SYSTEM.
8. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND
DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO
MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND
WITH NO MORE THAN 1:48 CROSS SLOPE.
9. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO
COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS' ASSOCIATION. THE PROPERTY
OWNERS' ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON
OPEN SPACE AREAS.
10. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND
GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO
CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS
AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
11. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER
APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS
TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL
BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE
ADEQUATE VISIBILITY.
12. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE
AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT
SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR
APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR
OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.
PROPOSED CONTOURS
BUILDING ENVELOPE
2 3
5 6
1
4
Key Map
THE NATURAL HAIBTAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONE.
100' SETBACK
ABANDONED WELL
R350'
5' MOWN SOFT
SURFACE TRAIL
(TYP.)
5' MOWN SOFT
SURFACE TRAIL
(TYP.)
STREET LIGHT
(TYP.)
W
W W W W
W
W
W
W
W W
UD
UD
UD
15" SS 15" SS 15" SS 15" SS 15" SS 15" SS 15" SS 15" SS
15" SS
15" SS
12" W 12" W
12" W 12" W
12" W 12" W 12" W 12" W 12" W 12" W 12" W
12" W
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD SD
SD SD
SD
S
S
S
S
S
S
SS
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
14" W 14" W
14" W 14" W
14" W 14" W
14" W 14" W
14" W 14" W
A.V.
4" W 4" W
4" W
4" W 4" W
V
.P.
W
W
W
W
W
W
W
W
W
W
V.P.
V.P.
A.R.V.
GAS
GAS
V.P.
X
G
G G
G
G
G
G
E
E
E
E
E
E
E
E
E
W
V
WV
WV
WV
WV
WV
X
V.P.
WV
WV
X
X
X X
M
X
F
E
S
M M
F
E
S
F
E
S
M
TELE
F.O.
TELE
F
E
S
MGAS
F
E
S
M
F
E
S
TELE
F
E
S
M
F
E
S
X
W
S
O
V.P.
VAULT
CABLE
BOX
CABLE
H2O
V.GAS P.
GAS
10" W
10" W 10" W
10" W
10" W
OHE
OHE
B
B
B
B
B
B
B
B
A.V.
AW
W W
W
E
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
12" W 12" W
12" W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
W
W
W
S
S
S
S
S
S S
S
S
S
S
S
S
W W
W
W
W
W
W
W
W
S
S
S
S S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S S
W
W
W
W
W W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S S
S
W W
W W W
W
W
W
W
W
S
S
S S
S
S SSS
S
S
S
S
S W W
W W W
W
W W
W
W
W W
W
W W
W
W
W W
W
W W W
W
W W W
W
W W
S S S
S S
S S
S S S S
S
S S S S
S S
S S S
S
W S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
S
S
14" W 14" W
W
A.V.
A.V.
W
W
LOD
LOD
OF:
SHEET NUMBER:
FORT COLLINS, CO 80524
COUNTRY CLUB
RESERVE
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Berthoud,CO 80513
T
B
970.532.5891
TBGroup.us
PREPARED FOR
REVISIONS
SHEET INFORMATION
DATE
SEAL
7
PROJECT TITLE
SHEET TITLE
ISSUE DATE
HILLSIDE COMMERCIAL
GROUP, LLC
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
MAY 29, 2019
FINAL
DEVELOPMENT
PLAN
1st Submittal 12/12/18
2nd Submittal 3/13/19
3rd Submittal 5/29/19
Site Plan
S 3.0
Site Plan
SCALE 1" = 50'-0"
0 50' 75' 100' NORTH
MATCH LINE - SHEET 6
MATCH LINE - SHEET 2
WINGED
FOOT DR.
KIAWAH DR.
350' SETBACK
OIL/GAS (TYP.)
TURNBERRY RD.
E. DOUGLAS RD.
LIMIT OF WORK
LIMIT OF WORK
5' MOWN SOFT
SURFACE TRAIL
(TYP.)
EXISTING CONTOURS
EASEMENT LINE
PROPERTY LINE
Legend
Site Plan Notes
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED
AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES,
UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS,
TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH
THESE PLANS.
5. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE
CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE
UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.
6. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY
PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE
CITY.
7. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE
EXTINGUISHING SYSTEM.
8. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND
DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO
MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND
WITH NO MORE THAN 1:48 CROSS SLOPE.
9. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO
COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS' ASSOCIATION. THE PROPERTY
OWNERS' ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON
OPEN SPACE AREAS.
10. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND
GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO
CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS
AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
11. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER
APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS
TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL
BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE
ADEQUATE VISIBILITY.
12. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE
AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT
SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR
APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR
OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.
PROPOSED CONTOURS
BUILDING ENVELOPE
2 3
5 6
1
4
Key Map
NATURAL HABITAT
BUFFER ZONE
BOUNDARY (TYP.)
THE NATURAL HAIBTAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONE.
STREET LIGHT
(TYP.)
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
UD UD UD UD
12" W 12" W 12" W 12" W 12" W 12" W 12" W
12" W 12" W 12" W 12" W 12" W
12" W 12" W 12" W 12" W 12" W
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD SD
SD SD
SD SD
SD SD
SD
SD
SD
SD
SD SD SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD SD
W
W
W
W
S
S
S
S
W
W
W
W
W
S
S
S
S
S
S
S
SSS
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W S
S
LOD LOD
LOD
LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
4" W 4" W
4" W
4" W 4" W
V
.P.
W
W
W
W
W
W
W
W
W
W
V.P.
V.P.
A.R.V.
GAS
GAS
V.P.
X
G
G G
G
G
G
G
E
E
E
E
E
E
E
E
E
W
V
WV
WV
WV
WV
WV
X
V.P.
WV
WV
X
X
X X
M
X
F
E
S
M M
F
E
S
F
E
S
M
TELE
F.O.
TELE
F
E
S
MGAS
F
E
S
M
F
E
S
TELE
F
E
S
M
F
E
S
X
W
S
O
V.P.
VAULT
CABLE
BOX
CABLE
H2O
V.GAS P.
GAS
10" W
10" W 10" W
10" W
10" W
OHE
OHE
B
B
B
B
B
B
B
B
A.V.
AW
W W
W
E
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
12" W 12" W
12" W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
W
W
W
S
S
S
S
S
S S
S
S
S
S
S
S
W W
W
W
W
W
W
W
W
S
S
S
S S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S S
W
W
W
W
W W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S S
S
W W
W W W
W
W
W
W
W
S
S
S S
S
S SSS
S
S
S
S
S W W
W W W
W
W W
W
W
W W
W
W W
W
W
W W
W
W W W
W
W W W
W
W W
S S S
S S
S S
S S S S
S
S S S S
S S
S S S
S
W S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
S
S
14" W 14" W
W
A.V.
A.V.
W
W
LOD
LOD
OF:
SHEET NUMBER:
FORT COLLINS, CO 80524
COUNTRY CLUB
RESERVE
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Berthoud,CO 80513
T
B
970.532.5891
TBGroup.us
PREPARED FOR
REVISIONS
SHEET INFORMATION
DATE
SEAL
7
PROJECT TITLE
SHEET TITLE
ISSUE DATE
HILLSIDE COMMERCIAL
GROUP, LLC
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
MAY 29, 2019
FINAL
DEVELOPMENT
PLAN
1st Submittal 12/12/18
2nd Submittal 3/13/19
3rd Submittal 5/29/19
Site Plan
S 2.0
Site Plan
SCALE 1" = 50'-0"
0 50' 75' 100' NORTH
MATCH LINE - SHEET 3
MATCH LINE - SHEET 5
MATCH LINE - SHEET 1
WINGED FOOT DR.
ROYAL TROON AVE.
CARNOUSTIE DR.
50' WETLAND BUFFER
(145' AVERAGE DEPTH TO
REAR LOT LINES)
50' WETLAND BUFFER
(145' AVERAGE DEPTH TO
REAR LOT LINES)
EXISTING WETLAND
(PROTECT-IN-PLACE)
E. DOUGLAS RD.
LIMIT OF WORK
EXISTING CONTOURS
EASEMENT LINE
PROPERTY LINE
Legend
Site Plan Notes
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED
AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES,
UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS,
TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH
THESE PLANS.
5. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE
CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE
UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.
6. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY
PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE
CITY.
7. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE
EXTINGUISHING SYSTEM.
8. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND
DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO
MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND
WITH NO MORE THAN 1:48 CROSS SLOPE.
9. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO
COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS' ASSOCIATION. THE PROPERTY
OWNERS' ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON
OPEN SPACE AREAS.
10. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND
GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO
CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS
AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
11. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER
APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS
TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL
BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE
ADEQUATE VISIBILITY.
12. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE
AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT
SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR
APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR
OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.
PROPOSED CONTOURS
BUILDING ENVELOPE
2 3
5 6
1
4
Key Map
NATURAL HABITAT
BUFFER ZONE
BOUNDARY (TYP.)
NATURAL HABITAT
BUFFER ZONE
BOUNDARY (TYP.)
THE NATURAL HAIBTAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONE.
5' MOWN SOFT
SURFACE TRAIL
(TYP.)
STREET LIGHT
(TYP.)
X
X
X
X X
X
F
E
S
M M
F
E
S
F
E
S
M
M
X X
X
TELE
F.O.
TELE
F
E
S
10" W
10" W
10" W
10" W
10" W 10" W
10" W
10" W
10" W
10" W 10" W
10" W
10" W
10" W
B
AW
W
LOD
LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD
LOD LOD
LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD LOD
LOD LOD
LOD LOD
LOD
LOD LOD
LOD LOD
LOD
12" W 12" W
12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
S
S
S
S
S
W
W
W
W
W
W
W
W
W
S
S
S
S
S W
4" W 4" W
4" W
4" W 4" W
V
.P.
W
W
W
W
W
W
W
W
W
W
V.P.
V.P.
A.R.V.
GAS
GAS
V.P.
X
G
G G
G
G
G
G
E
E
E
E
E
E
E
E
E
W
V
WV
WV
WV
WV
WV
X
V.P.
WV
WV
X
X
X X
M
X
F
E
S
M M
F
E
S
F
E
S
M
TELE
F.O.
TELE
F
E
S
MGAS
F
E
S
M
F
E
S
TELE
F
E
S
M
F
E
S
X
W
S
O
V.P.
VAULT
CABLE
BOX
CABLE
H2O
V.GAS P.
GAS
10" W
10" W 10" W
10" W
10" W
OHE
OHE
B
B
B
B
B
B
B
B
A.V.
AW
W W
W
E
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
12" W 12" W
12" W
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
W
W
W
S
S
S
S
S
S S
S
S
S
S
S
S
W W
W
W
W
W
W
W
W
S
S
S
S S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S S
W
W
W
W
W W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
S
S
S
S S
S
S
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S S
S
W W
W W W
W
W
W
W
W
S
S
S S
S
S SSS
S
S
S
S
S W W
W W W
W
W W
W
W
W W
W
W W
W
W
W W
W
W W W
W
W W W
W
W W
S S S
S S
S S
S S S S
S
S S S S
S S
S S S
S
W S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
S
S
14" W 14" W
W
A.V.
A.V.
W
W
LOD
LOD
OF:
SHEET NUMBER:
FORT COLLINS, CO 80524
COUNTRY CLUB
RESERVE
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Berthoud,CO 80513
T
B
970.532.5891
TBGroup.us
PREPARED FOR
REVISIONS
SHEET INFORMATION
DATE
SEAL
7
PROJECT TITLE
SHEET TITLE
ISSUE DATE
HILLSIDE COMMERCIAL
GROUP, LLC
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
MAY 29, 2019
FINAL
DEVELOPMENT
PLAN
1st Submittal 12/12/18
2nd Submittal 3/13/19
3rd Submittal 5/29/19
Site Plan
Site Plan
SCALE 1" = 50'-0"
0 50' 75' 100' NORTH
MATCH LINE - SHEET 2
MATCH LINE - SHEET 4
BETHPAGE DR.
WINGED FOOT DR.
E. DOUGLAS RD.
350' SETBACK
OIL/GAS (TYP.)
OIL/GAS
WELL HEAD #1
350' SETBACK
OIL/GAS (TYP.)
LIMIT OF WORK
LIMIT OF WORK
S1.0
EXISTING CONTOURS
EASEMENT LINE
PROPERTY LINE
Legend
Site Plan Notes
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED
AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES,
UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS,
TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH
THESE PLANS.
5. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE
CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE
UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.
6. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY
PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE
CITY.
7. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE
EXTINGUISHING SYSTEM.
8. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND
DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO
MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND
WITH NO MORE THAN 1:48 CROSS SLOPE.
9. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO
COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS' ASSOCIATION. THE PROPERTY
OWNERS' ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON
OPEN SPACE AREAS.
10. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND
GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO
CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS
AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
11. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER
APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS
TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL
BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE
ADEQUATE VISIBILITY.
12. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE
AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT
SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR
APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE
ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR
OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.
PROPOSED CONTOURS
BUILDING ENVELOPE
2 3
5 6
1
4
Key Map
NATURAL HABITAT
BUFFER ZONE
BOUNDARY (TYP.)
THE NATURAL HAIBTAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE
LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES
WITHIN THE NATURAL HABITAT BUFFER ZONE.
150' SETBACK
ABANDONED WELL
R350'
STREET LIGHT
(TYP.)
E E
E
E
E
E
E
E
W
V
WVWV
WV
WV
WV
V.P.
WV
WV
M
F
E
S
M M
F
E
S
F
E
S
M
M
TELE
F.O.
TELE
F
E
S
F
E
S
F
E
S
MM
MGAS
F
E
S
GAS
F
E
S
E
F
E
S
M
F
E
S
TELE
F
E
S
M
F
E
S
W
S
O
V.P.
VAULT
CABLE
BOX
CABLE
M
M
H2O
V.GAS P.
GAS
10" W
10" W 10" W
10" W
10" W
10" W
10" W 10" W
10" W
10" W
10" W
OHE OHE OHE
OHE
OHE
OHE OHE OHE
OHE
B
B
B
B
B
B
B
B
ST
ST
A.V.
AW
W
W W
W
W W W W
W
E
E
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD
LOD
LOD
UD
UD
15" SS 15" SS 15" SS
15" SS
12" W
12" W 12" W
12" W 12" W 12" W 12" W 12" W 12" W
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD SD
SD
SD
SD
SD
SD
SD
SD
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
S
S S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S S
S
S
W
W
W
W
W
W
W
W W
W
W
W
W
W
S
S
S
S
W
W
W
W W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S S
S S
S
S
W
W
W W
W
W
W
W
W
W
S
S
S
S
S
S SSS
S
S
S
S
S W
W W
W W
W
W W
W W
W W
W W
W W
W
W W
W W
W W
W
W
W
W W
W
W
S
S S
S S
S
S S
S S
S
S S
S S S
S S
S
S S
S
W
S
S
S
S
S
S
S
S
S
S
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
W
S
S
14" W
14" W
14" W 14" W
14" W
W
A.V.
A.V.
W
W
LOD
LOD
LOD
LOD
SD SD SD SD SD SD SD
SD SD SD SD SD
W S W S W S W S
S
6'
HOUSE
DRIVEWAY
WALKWAY
TREE LAWN
W
ROAD
TYPICAL
CORNER
LOT
20'
STOP SIGN
40' TYP.
STREET
LIGHT
8'
S
6'
HOUSE
40'
STREET
LIGHT
DRIVEWAY
WALKWAY
TREE LAWN
W
TYPICAL
NON-CORNER
LOT
ROAD
OF:
SHEET NUMBER:
FORT COLLINS, CO 80524
COUNTRY CLUB
RESERVE
GROUP
landscape architecture|planning|illustration
444 Mountain Ave.
Berthoud,CO 80513
T
B
970.532.5891
TBGroup.us
PREPARED FOR
REVISIONS
SHEET INFORMATION
DATE
SEAL
7
PROJECT TITLE
SHEET TITLE
ISSUE DATE
HILLSIDE COMMERCIAL
GROUP, LLC
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
CALL UTILITY NOTIFICATION CENTER OF
COLORADO
Know what'sbelow.
Call before you dig.
R
MAY 29, 2019
FINAL
DEVELOPMENT
PLAN
1st Submittal 12/12/18
2nd Submittal 3/13/19
3rd Submittal 5/29/19
Sheet Index
S 0.0 - OVERALL SITE PLAN / COVER SHEET & NOTES
S 1.0 - SITE PLAN
S 2.0 - SITE PLAN
S 3.0 - SITE PLAN
S 4.0 - SITE PLAN
S 5.0 - SITE PLAN
S 6.0 - SITE PLAN
Overall Site Plan
Cover Sheet & Notes
S 0.0
Legal Description
Owner's Certification of Approval:
THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL OWNERS
OF REAL PROPERTY DESCRIBED ON THIS SITE PLAN AND DO HEREBY CERTIFY THAT
I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID SITE PLAN.
IN WITNESS WHEREOF, WE HAVE HEREUNTO SET OUR HANDS AND SEALS THIS THE
_______ DAY OF _______________________, 20_____.
OWNER , PROSPECTS STATION. A COLORADO LIMITED LIABILITY COMPANY
BY:___________________________________
CONSTANCE DOHN , MANAGER
NOTARIAL CERTIFICATE
STATE OF COLORADO)
COUNTY OF ___________________)
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME
BY________________________________________________
THIS ______ DAY OF ________________________, 20_____.
MY COMMISSION EXPIRES:_____________ __________________
NOTARY PUBLIC
(SEAL)
A TRACT OF LAND BEING THE NORTH HALF OF THE NORTHEAST QUARTER SECTION 30, TOWNSHIP 8
NORTH, RANGE 68 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER,
STATE OF COLORADO.
Vicinity Map:
Site
SQUARE FEET ACRES % OF
RESIDENTIAL LOTS 945,402 21.70 27.1%
COMMON OPEN SPACE 2,039,550 46.82 58.3%*
INTERNAL ROW 325,828 7.48 9.3%
PERIMETER DEDICATED ROW 184,472 4.23 5.3%
TOTAL AREA: 3,492,994 80.19 100%
*PER LAND USE CODE SECTION 4.2(E)(2)(b), CLUSTER DEVELOPMENT SHALL SET ASIDE AT
LEAST 50% OF THE TOTAL LAND AREA OF THE PROPOSED DEVELOPMENT AS PRIVATE OR
PUBLIC OPEN SPACE THAT IS PERMANENTLY PRESERVED AS OPEN SPACE THROUGH
DEDICATION OF OWNERSHIP.
58% OF THE TOTAL PROJECT AREA HAS BEEN PRESERVED FOR OPEN SPACE TO BE
MAINTAINED BY THE HOA
*ANY FENCING INSTALLED AROUND OIL WELLS SHALL NOT REDUCE THE TOTAL OPEN SPACE
OF THE DEVELOPMENT TO LESS THAN 50%.
Area Coverage
Planning Approval:
BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OF THE
CITY OF FORT COLLINS, COLORADO THIS__________DAY OF _________________________ A.D.,
20_______.
_____________________________________________________________________________________
DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES
Land-Use Statistics
EXISTING ZONING: UE - URBAN ESTATE
LAND USE: DETACHED SINGLE FAMILY
DEVELOPMENT STANDARD: RESIDENTIAL CLUSTER DEVELOPMENT
EXISTING BUILDINGS: 0
PROPOSED RESIDENTIAL UNITS 160 UNITS - SINGLE FAMILY
TOTAL AREA 3,492,994 - 80.19 ACRES
PERIMETER DEDICATED ROW 184,472 SF - 4.23 ACRES
NET LAND AREA: 3,308,522 SF - 75.95 ACRES
UNITS PER ACRE 2.0 DU / ACRE
MINIMUM LOT SIZE N/A
SMALLEST LOT 4,950 SF
LARGEST LOT 10,620 SF
AVERAGE LOT SIZE 5,908 SF
Site Plan Notes
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE
CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND
SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS
AND OTHER SURVEY INFORMATION.
4. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS.
5. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A
CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY
DIFFUSION.
6. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO
CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY.
7. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM.
8. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND
AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE
ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE.
9. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE
AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS' ASSOCIATION. THE PROPERTY OWNERS' ASSOCIATION IS RESPONSIBLE FOR SNOW
REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS.
10. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED,
DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
11. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF
OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE
LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH
FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO
PROVIDE ADEQUATE VISIBILITY.
12. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY_FINDING.
ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY
LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX_INCH NUMERALS ON A CONTRASTING
BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR
OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE.
13. THE EXISTING PLUGGED AND ABANDONED OIL AND GAS WELL HEAD LOCATION SHALL REMAIN PERMANENTLY PLUGGED AND ABANDONED IN ACCORDANCE
WITH THE COLORADO OIL AND GAS CONSERVATION COMMISSION STANDARDS. PRIOR TO CITY AUTHORIZATION OF ANY RESIDENTIAL BUILDING PERMIT IN
CONJUNCTION WITH THESE FINAL PLANS, THE OWNER SHALL CONDUCT A SOIL GAS SURVEY OF ALL PLUGGED AND ABANDONED OIL AND GAS WELL HEAD
LOCATIONS ON THE PROPERTY AND PROVIDE THE CITY AND THE COGCC WITH THE RESULTS OF THE SURVEY. SHOULD THE RESULTS OF THE SURVEY
INDICATE THAT ANY WELL HEAD IS NOT PROPERLY PLUGGED AND ABANDONED IN ACCORDANCE WITH THE COGCC STANDARDS, THE OWNER OR COGCC SHALL
RE-PLUG THE WELL HEAD AND PROVIDE FURTHER DOCUMENTATION TO THE CITY AND COGCC THAT THE WELL IS PROPERTY PLUGGED IN ACCORDANCE WITH
ALL COGCC REGULATIONS. UPON COMPLETION AND COGCC INITIAL ACCEPTANCE OF ON-SITE WELL PLUGGING AND RECLAMATION, ANY CONTINUED
MAINTENANCE, REPAIRS, ALTERATIONS, AND/OR WELL HEAD MONITORING SHALL BE THE RESPONSIBILITY OF THE HOMEOWNERS ASSOCIATION OR OTHER
APPROVED CITY ENTITY.
Overall Site Plan
SCALE 1" = 200'
0 200' 300' 400' NORTH
1 2 3
4 5 6
E. DOUGLAS RD.
TURNBERRY RD.
WINGED FOOT DR.
KIAWAH DR.
BALTUSROL CT.
BALTUSROL DR.
CARNOUSTIE
DR.
ROYAL TROON AVE.
OIL/GAS
WELL HEAD
#4
OIL/GAS
WELL HEAD #3
OIL/GAS
WELL HEAD #2
OIL/GAS
WELL HEAD #1
350' SETBACK
OIL/GAS (TYP.)
350' SETBACK
OIL/GAS (TYP.)
350' SETBACK
OIL/GAS (TYP.)
350' SETBACK
OIL/GAS (TYP.)
EXISTING
WETLAND
(PROTECT-IN-PLACE)
50' WETLAND
BUFFER (TYP.)
Country Club Reserve
Site Plan
Fort Collins, Colorado 80524
Urban Estate Residential Cluster Plan Setback Requirements
SCALE 1" = 30'
0 30' 45' 60'
BUILDING ENVELOPE
(TYP.)
LOT LINE (TYP.)
8' MIN. REAR YARD
SETBACK
RIGHT OF WAY (TYP.)
TYPICAL
LOT
WETLAND BOUNDARY
(TYP.)
150' SETBACK
ABANDONED
WELL
NATURAL HABITAT
BUFFER ZONE
BOUNDARY (TYP.)
NATURAL HABITAT
BUFFER ZONE
BOUNDARY (TYP.)
Typical Non-Corner Lot Detail
Typical Corner Lot Detail
BETHPAGE DR.
15' MIN. FRONT
YARD SETBACK
5' MIN. SIDE YARD
SETBACK