HomeMy WebLinkAboutDUTCH BROS - PDP190008 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANSSITE
1218 W. Ash, Suite A
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJECT NAME
KENSINGTON COMMONS
DUTCH BROS COFFEE
COVER SHEET
4/22/2019
N/A
N/A
ES
MPO
1380-165-00
1 of 5
M SQUARED, LLC
1600 EAST MULBERRY ST., UNIT 1
FORT COLLINS, COLORADO 80525
CONTACT: NATE FRARY
vicinity map
Scale:: 1"=500'
UTILITY PLANS FOR:
KENSINGTON COMMONS
DUTCH BROS COFFEE
LOCATED IN THE SOUTHEAST QUARTER OF SECTION 35,
TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN
CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
APRIL 2019
AD ALGEBRAIC DIFFERENCE
AE ACCESS EASEMENT
ARV AIR RELEASE VALVE
ASSY ASSEMBLY
BLDG BUILDING
BOV BLOW OFF VALVE
BW BOTTOM OF WALL
C&G CURB AND GUTTER
CL CENTERLINE
CMP CORRUGATED METAL PIPE
DE DRAINAGE EASEMENT
EAE EMERGENCY ACCESS EASEMENT
EG EXISTING GRADE
EL ELEVATION
ENV ENVELOPE
ES EMERGENCY SPILLWAY
ESMT EASEMENT
EX EXISTING
FES FLARED END SECTION
FH FIRE HYDRANT
FL FLOWLINE
GB GRADE BREAK
GD GROUND
KENSINGTON DRIVE
MASON STREET
SOUTH COLLEGE AVENUE
LOT 1
LOT 2 THE GATEWAY AT HARMONY ROAD P.U.D.
THIRD FILING LOT 3
R
evisions
No. Date Description By
Revisions
No. Date Description By
0
SCALE: 1" = 20'
20 10 20 40
1218 W. Ash, Suite A
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJECT NAME
KENSINGTON COMMONS
DUTCH BROS COFFEE
DEMOLITION PLAN
4/22/2019
N/A
N/A
ES
MPO
1380-165-00
2 of 5
M SQUARED, LLC
1600 EAST MULBERRY ST., UNIT 1
FORT COLLINS, COLORADO 80525
CONTACT: NATE FRARY
PROP
BLDG
FFE=
37.30
KENSINGTON DRIVE
SOUTH COLLEGE AVENUE
LOT 1
BLANKET
UE, DE, AE
LOT 2
BLANKET
UE, DE, AE
MASON STREET
LOT 1
LOT 2 THE GATEWAY AT HARMONY ROAD P.U.D.
THIRD FILING LOT 3
R
evisions
No. Date Description By
Revisions
No. Date Description By
0
SCALE: 1" = 20'
20 10 20 40
1218 W. Ash, Suite A
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJECT NAME
KENSINGTON COMMONS
DUTCH BROS COFFEE
UTILITY PLAN
4/22/2019
N/A
N/A
ES
MPO
1380-165-00
3 of 5
M SQUARED, LLC
1600 EAST MULBERRY ST., UNIT 1
FORT COLLINS, COLORADO 80525
CONTACT: NATE FRARY
NOTES:
1. ALL STORM SEWER AND SANITARY SEWER, AS WELL AS POWER AND OTHER "DRY" UTILITY INSTALLATIONS, SHALL CONFORM TO
THE CITY OF FORT COLLINS STANDARDS AND SPECIFICATIONS CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE LOCAL
ENGINEER.
2. STORM SEWER PIPE SHALL BE RCP OR PVC WITH WATER TIGHT JOINTS AS SPECIFIED ON THE PLAN. ALL STORM SEWER SHALL BE
INSPECTED BY THE CITY OF FORT COLLINS (COFC).
3. LENGTH OF PIPE IS MEASURED FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE AND INCLUDES THE FLARED END
SECTION.
4. ALL WATER CONSTRUCTION SHALL CONFORM TO THE CITY OF FORT COLLINS-LOVELAND WATER STANDARDS AND
PROP
BLDG
FFE=
37.30
FF=37.45
LOT 1
BLANKET
UE, DE, AE
LOT 2
BLANKET
UE, DE, AE
KENSINGTON DRIVE
SOUTH COLLEGE AVENUE
MASON STREET
LOT 1
LOT 2 THE GATEWAY AT HARMONY ROAD P.U.D.
THIRD FILING LOT 3
PERVIOUS PAVER DETAIL SECTION
NTS
Revisions
No. Date Description By
Revisions
No. Date Description By
0
SCALE: 1" = 20'
20 10 20 40
1218 W. Ash, Suite A
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJECT NAME
KENSINGTON COMMONS
DUTCH BROS COFFEE
GRADING PLAN
4/22/2019
N/A
N/A
ES
MPO
1380-165-00
4 of 5
M SQUARED, LLC
1600 EAST MULBERRY ST., UNIT 1
FORT COLLINS, COLORADO 80525
CONTACT: NATE FRARY
NOTES:
1. ALL GRADING SHALL BE CONFINED TO THE PROPERTY BEING DEVELOPED OR ADJACENT PUBLIC RIGHT-OF-WAY. NO GRADING SHALL
BE DONE OUTSIDE OF PROPERTY LINES UNLESS OTHERWISE SHOWN.
PROP
BLDG
FF=
37.30
FF=37.45
LOT 1
BLANKET
UE, DE, AE
LOT 2
BLANKET
UE, DE, AE
Revisions
No. Date Description By
Revisions
No. Date Description By
0
SCALE: 1" = 20'
20 10 20 40
1218 W. Ash, Suite A
Windsor , Colorado 80550
Phone: (970) 674-3300
Fax: (970) 674-3303
I N T E R W E S T C O N S U L T I N G G R O U P
PREPARED FOR
PROJ. NO.
DATE:
SCALE (H):
SCALE (V):
CHECKED BY:
DESIGNED BY:
PROJECT NAME
KENSINGTON COMMONS
DUTCH BROS COFFEE
DRAINAGE PLAN
4/22/2019
N/A
N/A
ES
MPO
1380-165-00
5 of 5
M SQUARED, LLC
1600 EAST MULBERRY ST., UNIT 1
FORT COLLINS, COLORADO 80525
CONTACT: NATE FRARY
PROPOSED MINOR CONTOUR
PROPOSED MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
LEGEND
PROPOSED DIRECTION OF OVERLAND FLOW
MINOR STORM RUNOFF COEFFICIENT
DRAINAGE BASIN AREA, ACRES
PROPOSED DRAINAGE BASIN ID
DESIGN POINT
PROPOSED DRAINAGE
BASIN DIVIDE LINE
SPECIFICATIONS CURRENT AT THE DATE OF APPROVAL OF THE PLANS BY THE CITY OF FORT COLLINS.
5. WATER MAINS AND FIRE LINES SHALL BE PVC(C900) AS SPECIFIED BY THE COFC. THE MINIMUM COVER OVER WATER LINES IS 5.5
FEET AND THE MAXIMUM COVER IS 6.5 FEET UNLESS OTHERWISE APPROVED BY THE COFC.
6. ALL WATER SERVICES SHALL BE INSTALLED AT A MINIMUM OF 5 FEET BELOW FINISHED FLOOR ELEVATION AND SHALL BE TYPE K
COPPER AS SPECIFIED BY COFC.
7. ALL SANITARY SEWER PIPE SHALL BE PVC (SDR35) UNLESS OTHERWISE NOTED ON THE PLAN. SEWER PIPE
SHALL BE AS SPECIFIED BY THE CITY OF FORT COLLINS STANDARD PLANS AND SPECIFICATIONS.
8. 2" FORCE MAIN SHALL BE HDPE PIPE INSTALLED AT A MINIMUM OF 4' BELOW FINISH GRADE WITH TRACER WIRE.
9. EXISTING UTILITIES UNDER PAVERS MAY NEED TO BE LOWERED. CONTRACTOR TO VERIFY HORIZONTAL AND
VERTICAL LOCATIONS.
10. SEE ARCHITECTURAL DRAWINGS FOR WALL LOCATION DETAILS OF GAS METERS, ELECTRIC METERS, AND
TELEPHONE TERMINALS.
11. LIMITS OF STREET CUT SHOWN ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY CITY
ENGINEER INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH THE CITY STREET REPAIR STANDARDS.
12. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE IMPROVEMENTS
AND/OR PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE
FIRST CERTIFICATE OF OCCUPANCY.
GV GATE VALVE
HP HIGH POINT
IE IRRIGATION EASEMENT
INV INVERT
IRR IRRIGATION
LF LINEAR FEET
LP LOW POINT
LT LEFT
MH MANHOLE
PAE PUBLIC ACCESS EASEMENT
PE PEDESTRIAN EASEMENT
PERF PERFORATED
PC POINT OF CURVATURE
PCC POINT OF COMPOUND CURVATURE
PCR POINT OF CURB RETURN
PI POINT OF INTERSECTION
PRC POINT OF REVERSE CURVATURE
PT POINT OF TANGENCY
PVC POLYVINYL CHLORIDE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
RT RIGHT
SAN SANITARY SEWER
SDMH STORM DRAIN MANHOLE
STA STATION
STM STORM SEWER
TC TOP OF CONCRETE
TB THRUST BLOCK
TBW TOP BACK OF WALK
TOF TOP OF FOUNDATION
TW TOP OF WALL
TYP TYPICAL
UE UTILITY EASEMENT
VCP VITRIFIED CLAY PIPE
VPC VERTICAL POINT OF CURVATURE
VPI VERTICAL POINT OF INTERSECTION
VPT VERTICAL POINT OF TANGENCY
ABBREVIATION LIST
PROPOSED STREET LIGHT
PROPOSED STORM MANHOLE
PROPOSED STORM SEWER
PROPOSED WATER CURB STOP/ METER PIT
PROPOSED SANITARY SEWER CLEANOUT
EXISTING SANITARY SEWER MAIN
PROPOSED TELEPHONE
EXISTING GAS
EXISTING STORM SEWER
EXISTING WATER MAIN
EXISTING STORM SEWER MANHOLE
EXISTING SANITARY SEWER MANHOLE
PROPOSED STORM INLET
LEGEND
PROPOSED CONCRETE
PROPOSED MINOR CONTOUR
PROPOSED SPOT ELEVATION
EXISTING SPOT ELEVATION
PROPOSED MAJOR CONTOUR
EXISTING MINOR CONTOUR
EXISTING MAJOR CONTOUR
EXISTING UTILITY POLE
EXISTING GUY WIRE
PROPOSED GAS
EXISTING ELECTRIC LINE PROPOSED ELECTRIC
EXISTING TELEPHONE LINE
EXISTING FIRE HYDRANT PROPOSED FIRE HYDRANT
EXISTING WATER VALVE
PROPOSED SANITARY SEWER MAIN
PROPOSED WATER MAIN
EXISTING CONCRETE
RIGHT-OF-WAY LINE
EXISTING FLOWLINE, CURB & GUTTER
EASEMENT LINE
PROPOSED FLOWLINE, CURB & GUTTER
PROPOSED FENCE/RAILING
EXISTING OVERHEAD UTILITY
EXISTING STORM SEWER INLET
PROPOSED WATER VALVE
PROPOSED SANITARY SEWER MANHOLE
PROPOSED UTILITY POLE
EXISTING STREET LIGHT
EXISTING EDGE OF ASPHALT
III
III
III
III
III
III
PROPOSED FLARED END SECTION (FES)
ARCHITECT
r4 Architects
226 Remington STreet Unit 3
Fort Collins, CO 80524
PH. 970.224.0630
Contact: Matt Rankin
PLANNER
TB Group
444 Mountain Avenue
Berhoud, CO 80513
PH. 970.532.5891
Contact: Cathy Mathis
ENGINEER
Interwest Consulting Group
1218 W. Ash, Suite A
Windsor, Colorado 80550
PH. 970.674.3300
Contact: Mike Oberlander
SURVEYOR
King Surveyors
650 East Garden Drive
Windsor, Colorado 80550
PH. 970.686.5011
Contact: Paul Groves
INDEMNIFICATION STATEMENT:
THESE PLANS HAVE BEEN REVIEWED BY THE LOCAL ENTITY FOR
CONCEPT ONLY. THE REVIEW DOES NOT IMPLY RESPONSIBILITY BY THE
REVIEWING DEPARTMENT, THE LOCAL ENTITY ENGINEER, OR THE
LOCAL ENTITY FOR ACCURACY AND CORRECTNESS OF THE
CALCULATIONS. FURTHERMORE, THE REVIEW DOES NOT IMPLY THAT
QUANTITIES OF ITEMS ON THE PLANS ARE THE FINAL QUANTITIES
REQUIRED. THE REVIEW SHALL NOT BE CONSTRUED IN ANY REASON AS
ACCEPTANCE OF FINANCIAL RESPONSIBILITY BY THE LOCAL ENTITY
FOR ADDITIONAL QUANTITIES OF ITEMS SHOWN THAT MAY BE
REQUIRED DURING THE CONSTRUCTION PHASE.
INDEX OF SHEETS
Sheet No. Description of Sheets
PRELIMINARY
NOT FOR CONSTRUCTION
BENCHMARKS:
PROJECT DATUM: NAVD88
BENCHMARK #48-01
APPROXIMATELY 1/2 MILE SOUTH OF HORSETOOTH ROAD, WEST SIDE OF COLLEGE AVENUE AT THE
ENTRANCE TO BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING
LOT, ON A CONCRETE CURB.
ELEVATION=5036.76
BENCHMARK #7-13
NORTHWEST CORNER OF HORSETOOTH RD. AND STOVER ST., ON A CONCRETE TRAFFIC SIGNAL BASE.
ELEVATION=5005.69
PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING
DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR
VERTICAL DATUMS.
IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY
PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED:
NGVD29 UNADJUSTED (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.19'.
UTILITY CONTACTS:
City of Fort Collins
Fort Collins, Colorado 80522
700 Wood Street
TELEPHONE SERVICE
Century Link
3702 Automation Dr, Suite 106
Fort Collins, Colorado 80525
Contact: Engineering Office
NATURAL GAS
Xcel Energy
1901 E. Horsetooth Road
Contact: Stephanie Rich
UTILITIES ENGINEER Fort Collins, Colorado 80525
Dan Mogen
Ph. 970.224.6192
LIGHT & POWER
Ph. 970.225.7828
Ph. 970.490.7508
COVER SHEET
DEMOLITION PLAN
UTILITY PLAN
GRADING PLAN
DRAINAGE PLAN
1
2
3
4
5
................................
................................
................................
................................
................................
................................
................................
................................
................................
Austin Kreager
Ph. 970.224.6152