Loading...
HomeMy WebLinkAboutDUTCH BROS - PDP190008 - SUBMITTAL DOCUMENTS - ROUND 2 - DRAINAGE REPORTPRELIMINARY DRAINAGE REPORT Dutch Bros Coffee Kensington Commons Prepared for: M Squared, LLC 7303 S. Timberline Road Fort Collins, CO 80525 Prepared by: Interwest Consulting Group 1218 West Ash, Suite A Windsor, Colorado 80550 (970) 674-3300 June 26, 2019 Job Number 1380-165-00 TABLE OF CONTENTS 1. GENERAL LOCATION AND DESCRIPTION ................................................................. 1 1.1 Location ........................................................................................................................... 1 1.2 Description of Property ................................................................................................. 1 1.3 Floodplain Submittal Requirements ............................................................................. 1 2. DRAINAGE BASINS AND SUB-BASINS .......................................................................... 2 2.1 Major Basin Description ................................................................................................ 2 2.2 Sub-basin Description .................................................................................................... 2 3. DRAINAGE DESIGN CRITERIA ....................................................................................... 2 3.1 Regulations ...................................................................................................................... 2 3.2 Directly Connected Impervious Area (DCIA) Discussion .......................................... 3 3.3 Development Criteria Reference and Constraints ...................................................... 4 3.4 Hydrologic Criteria ........................................................................................................ 4 3.5 Hydraulic Criteria .......................................................................................................... 5 3.6 Floodplain Regulations Compliance ............................................................................. 5 3.7 Modifications of Criteria ............................................................................................... 5 4. DRAINAGE FACILITY DESIGN ....................................................................................... 5 4.1 General Concept ............................................................................................................. 5 4.2 Specific Details ................................................................................................................ 5 5. CONCLUSIONS .................................................................................................................... 7 5.1 Compliance with Standards .......................................................................................... 7 5.2 Drainage Concept ........................................................................................................... 7 6. REFERENCES ....................................................................................................................... 7 APPENDIX APPENDIX A – VIC MAP AND DRAINAGE PLANS AND EXHIBITS ........................... A APPENDIX B – HYDROLOGIC COMPUTATIONS ............................................................ B APPENDIX C – HYDRAULIC COMPUTATIONS (PROVIDED AT FINAL) .................... C APPENDIX D – WATER QUALITY AND LID INFORMATION ....................................... D APPENDIX E – DETENTION INFORMATION ................................................................... E APPENDIX F – SOILS INFO AND REFERENCE MATERIALS ......................................... F 1 1. GENERAL LOCATION AND DESCRIPTION 1.1 Location The Dutch Bros Coffee Kensington Commons Development is located in the Southeast Quarter of Section 35, Township 7 North, Range 69 West of the Sixth Principal Meridian, in the City of Fort Collins, Larimer County, Colorado. Please refer to the vicinity map in Appendix A. The project is Lot 1 and 2 of Kensington Commons and is located north of Jiffy Lube at 121 Kensington Drive. South College Avenue is located to the east and Kensington Drive is to the north of the property. The property was originally developed for the Jiffy Lube and a gas station as The Gateway at Harmony P.U.D. First Filing in 1994. 1.2 Description of Property The site is approximately 0.8 acres of land and will consist of a new building, parking and drive aisles, and associated sidewalks. The Jiffy Lube will remain on Lot 2. The site generally slopes in an easterly direction at approximately 3-5%. The land is currently developed with existing parking and buildings. There are no offsite flows contributing to the site. The existing flow drains to an existing onsite inlet (containing an orifice plate) with some parking lot detention (much less than the 1994 design). According to FEMA Panel 08069C1000F (effective 12/19/2006) there are no mapped FEMA Floodways on this property, and the property is within Zone X. Please refer to Appendix F for hydrologic soil and FEMA information. 1.3 Floodplain Submittal Requirements The project is not within any FEMA or City of Fort Collins mapped floodplain. Therefore, a Floodplain Submittal is not required and a “City of Fort Collins Floodplain Review Checklist for 50% Submittals” has not been included with this report. 2 2. DRAINAGE BASINS AND SUB-BASINS 2.1 Major Basin Description The proposed development lies within the Mail Creek and then Fossil Creek Drainage Basins. The site has been previously studied in two reports: “Final Drainage Report the Gateway to Harmony Road P.U.D” (March 9, 1989) and “Final Drainage Report for Lot 1, The Gateway at Harmony Road P.U.D., First Filing for Jiffy Lube, Inc.” (October 13, 1993) both by Stewart and Associates, Inc. 2.2 Sub-basin Description Historically, the site drains to the east where it is collected by an existing inlet and discharged into an existing storm system in College Avenue which outfalls to Mail Creek and then ultimately to the Fossil Creek channel. The site originally was designed to have parking lot detention (6,174 cf required) with a 100-year 0.4 cfs release rate via a restrictor plate on the existing inlet located in the parking lot adjacent to College Avenue. This inlet releases into the storm system in College Avenue. Currently, the parking lot only has 621 cf of storage before it overtops at an elevation of 5036.4 ft. to College Avenue. Currently, during the 100-year storm event, the site produces a total of 7.7 cfs. Of that total, 0.7 cfs is free released to College Avenue, Kensington or the alley to the west. The remainder is detained in the parking lot and released over the curb at 5.0 cfs. Please refer to the attached Existing Conditions Drainage Plan and calculations. 3. DRAINAGE DESIGN CRITERIA 3.1 Regulations This report was prepared to meet or exceed the “City of Fort Collins Storm Drainage Design Criteria Manual” specifications. Where applicable, the criteria established in the “Urban Storm Drainage Criteria Manual” (UDFCD), developed by the Denver Regional Council of Governments, has been used. 3 3.2 Directly Connected Impervious Area (DCIA) Discussion Urban Drainage and Flood Control District (UDFCD) recommends a Four Step Process for receiving water protection that focuses on reducing runoff volumes, treating the water quality capture volume (WQCV), stabilizing drainageways and implementing long-term source controls. The Four Step Process applies to the management of smaller, frequently occurring events. Step 1: Employ Runoff Reduction Practices To reduce runoff peaks, volumes, and pollutant loads from urbanizing areas, implement Low Impact Development (LID) strategies, including Minimizing Directly Connected Impervious Areas (MDCIA). Runoff from the site shall be conveyed to underground water quality and detention facilities which reduces the rate of runoff and promotes settlement of particles. The project will also lower the imperviousness of the site. Step 2: Implement BMPs that Provide a Water Quality Capture Volume with Slow Release Once runoff has been minimized, runoff from the site shall be conveyed to underground detention facilities which reduces the rate of runoff and promotes settlement of particles. Step 3: Stabilize Drainageways Natural Drainageways are subject to bed and bank erosion due to increases in frequency, duration, rate and volume of runoff during and following development. Because the site will drain to an existing storm system, bank stabilization is unnecessary with this project. Step 4: Implement Site Specific and Other Source Control BMPs The proposed project will control pollutants by encouraging them to settle out inside the isolator row of the underground detention facilities before being released from the site. The proposed project will proactively control pollutants at their source by preventing pollution rather than removing contaminants once they have entered the stormwater system as compared to historic conditions. 4 3.3 Development Criteria Reference and Constraints The runoff from this site has been routed to conform to the requirements of the City Stormwater Department. Water quality capture volume and detention will be provided on site. The release rate for the site is 0.5 cfs per acre. The site’s water quality will be met through the use of an underground water quality system (an isolator row of a proposed ADS Stormtec system). The effective impervious area for the site has been reduced from the current condition of 78 percent to a proposed condition of 76 percent. Runoff reduction practices (LID techniques) are also required. No less than seventy five percent of any newly developed or redeveloped area, and any modification on a previously developed area for which a construction permit is required under City codes and regulations, must be treated using one or a combination of LID techniques. The project has 26,579 sf of impervious area. Basins A and B contain the entire 26,579 sf of impervious area and will be treated by the underground water quality and detention facilities which exceeds the 75% requirement. ADS Stormtec Chambers are proposed to achieve LID, water quality and detention. Please refer to the attached Proposed Impervious Exhibit delineating the new/modified impervious areas and the non-modified existing impervious areas. Please refer to Appendix D for LID calculations and information. 3.4 Hydrologic Criteria Runoff computations were prepared for the 2-year minor storm and 100-year major storm frequency utilizing the rational method. All hydrologic calculations associated with the basins are included in Appendix B of this report. Standard Form 8 (SF-8) provides time of concentration calculations for all sub- basins. Standard Form 9 (SF-9) provides a summary of the design flows for all Sub- basins and Design Points associated with this site. 5 3.5 Hydraulic Criteria All hydraulic calculations will be presented in the final drainage report and prepared in accordance with the City of Fort Collins Drainage Criteria. 3.6 Floodplain Regulations Compliance The project is not within any FEMA or City of Fort Collins mapped floodway. Therefore, a Floodplain Submittal is not required and a “City of Fort Collins Floodplain Review Checklist for 50% Submittals” has not been included with this report. 3.7 Modifications of Criteria There are no Modifications of Criteria for this project. 4. DRAINAGE FACILITY DESIGN 4.1 General Concept The majority of the proposed development will be collected and conveyed to the underground storage system where it will be treated for water quality and detention before being released into the College storm drain that ultimately conveys water into Mail Creek and then ultimately to the Fossil Creek channel. 4.2 Specific Details A summary of the drainage patterns within each basin is provided in the following paragraphs. Please refer to Appendix A for the drainage plan. Basin A is 0.18 acres and consists of the north drive aisle area and the proposed building. The basin drains to the curb inlet at Design Point a that collects flow from this area and conveys flow to the underground water quality and storage system. Roof drains will be directly connected to this storm system. 6 Basin B is 0.51 acres and consists of the south parking area and the existing Jiffy Lube building. The basin drains to the curb inlet at Design Point b that collects flow from this area and conveys flow to the underground water quality and storage system. Basin C is 0.05 acres and consists of one half of the drive aisle to the west. The basin maintains existing conditions and drains to the north and south in the curb and gutter. Basin D is 0.05 acres and is located on the east side of the property. The basin maintains existing conditions and sheets to the curb and gutter of South College Avenue. The water quality capture volume for the site was sized based on a 12-hour drain time and is 775 cf. Please refer to Appendix D for water quality information. The allowable detention release rate of 0.4 cfs, the required 100-year storage volume for the site is 5,973 cf. The Stormtec system will provide 6,266 cf of total storage. The total is reduced by 437 cf of volume in the bottom 6 inches of isolator rows used for water quality. Therefore, the system provides a 5,829 cf of detention storage. There will be some parking lot detention that will pond to an elevation of 5036.2 with a volume of 110 cf. Therefore, the total volume provided for detention is 5,939 cf. Detained flow will be released via a restrictor plate into the existing inlet and existing storm system in College Avenue and ultimately to the Mail Creek and then the Fossil Creek channel. Please refer to Appendix E for detention information. The underground storage system will contain a structure with a design bypass to split flows for treatment and detention. Water quality will be achieved in the isolator rows. A second outlet pipe 6 inches above the invert of the isolator row will convey larger storms to the system. The remainder will be detained in the chambers and aggregate volume surrounding and under the chambers. The system proposed for treatment and detention is the Stormtech MC3500 Chamber System. Further design will be provided during final submittal. 7 5. CONCLUSIONS 5.1 Compliance with Standards All computations that have been completed within this report are in compliance with the City of Fort Collins Storm Drainage Design Criteria Manual. 5.2 Drainage Concept The proposed drainage concepts presented in this report and on the construction plans adequately provides for stormwater quantity and quality treatment of proposed impervious areas. Conveyance elements have been designed to pass required flows and to minimize future maintenance. If, at the time of construction, groundwater is encountered, a Colorado Department of Health Construction Dewatering Permit will be required. 6. REFERENCES 1. City of Fort Collins, “Fort Collins Stormwater Criteria Manual”, adopted December 2018. 2. Urban Drainage and Flood Control District, “Urban Storm Drainage Criteria Manual”, Volumes 1 and 2, updated January 2016, and Volume 3 updated November 2010. 3. Stewart and Associates, Inc., “Final Drainage Report for Lot 1, The Gateway at Harmony Road P.U.D., First Filing for Jiffy Lube, Inc.” dated October 13, 1993. A APPENDIX A VICINITY MAP AND DRAINAGE PLANS AND EXHIBITS SITE vicinity map Scale:: 1"=500' FF=37.45 KENSINGTON DRIVE SOUTH COLLEGE AVENUE MASON STREET LOT 1 LOT 2 THE GATEWAY AT HARMONY ROAD P.U.D. THIRD FILING LOT 3 R evisions No. Date Description By Revisions No. Date Description By 0 SCALE: 1" = 20' 20 10 20 40 1218 W. Ash, Suite A Windsor , Colorado 80550 Phone: (970) 674-3300 Fax: (970) 674-3303 I N T E R W E S T C O N S U L T I N G G R O U P PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME KENSINGTON COMMONS DUTCH BROS COFFEE EXISTING CONDITIONS DRAINAGE PLAN 6/26/2019 N/A N/A ES MPO 1380-165-00 1 M SQUARED, LLC 7303 S. TIMBERLINE ROAD FORT COLLINS, COLORADO 80525 CONTACT: NATE FRARY EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR LEGEND EXISTING DIRECTION OF OVERLAND FLOW MINOR STORM RUNOFF COEFFICIENT DRAINAGE BASIN AREA, ACRES EXISTING DRAINAGE BASIN ID EXISTING DESIGN POINT EXISTING DRAINAGE BASIN DIVIDE LINE KENSINGTON DRIVE SOUTH COLLEGE AVENUE MASON STREET LOT 1 BLANKET UE, DE, AE LOT 2 BLANKET UE, DE, AE LOT 1 LOT 2 THE GATEWAY AT HARMONY ROAD P.U.D. THIRD FILING LOT 3 R evisions No. Date Description By Revisions No. Date Description By 0 SCALE: 1" = 20' 20 10 20 40 1218 W. Ash, Suite A Windsor , Colorado 80550 Phone: (970) 674-3300 Fax: (970) 674-3303 I N T E R W E S T C O N S U L T I N G G R O U P PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME KENSINGTON COMMONS DUTCH BROS COFFEE PROPOSED IMPERVIOUS EXHIBIT 6/18/2019 N/A N/A ES MPO 1380-165-00 2 M SQUARED, LLC 7303 S. TIMBERLINE ROAD FORT COLLINS, COLORADO 80525 CONTACT: NATE FRARY PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR LEGEND PROPOSED/MODIFIED IMPERVIOUS AREA NON-MODIFIED IMPERVIOUS AREA KENSINGTON DRIVE SOUTH COLLEGE AVENUE MASON STREET PROP BLDG FF= 37.30 FF=37.45 LOT 1 BLANKET UE, DE, AE LOT 2 BLANKET UE, DE, AE LOT 1 LOT 2 THE GATEWAY AT HARMONY ROAD P.U.D. THIRD FILING LOT 3 R evisions No. Date Description By Revisions No. Date Description By 0 SCALE: 1" = 20' 20 10 20 40 1218 W. Ash, Suite A Windsor , Colorado 80550 Phone: (970) 674-3300 Fax: (970) 674-3303 I N T E R W E S T C O N S U L T I N G G R O U P PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME KENSINGTON COMMONS DUTCH BROS COFFEE DRAINAGE PLAN 6/26/2019 N/A N/A ES MPO 1380-165-00 5 of 5 M SQUARED, LLC 7303 S. TIMBERLINE ROAD FORT COLLINS, COLORADO 80525 CONTACT: NATE FRARY PROPOSED MINOR CONTOUR PROPOSED MAJOR CONTOUR EXISTING MINOR CONTOUR EXISTING MAJOR CONTOUR LEGEND PROPOSED DIRECTION OF OVERLAND FLOW MINOR STORM RUNOFF COEFFICIENT DRAINAGE BASIN AREA, ACRES B APPENDIX B HYDROLOGIC COMPUTATIOS Interwest Consulting Group EXISTING DRAINAGE SUMMARY TABLE Design Tributary Area C (2 & 10) C (100) tc (10) tc (100) Q(2)tot Q(10)tot Q(100)tot Sub-basin REMARKS Point (ac) (min) (min) (cfs) (cfs) (cfs) 1 EX1 0.71 0.79 0.99 5.0 5.0 7.0 2.7 7.0 PARKING LOT DETENTION 2 EX2 0.07 0.95 1.00 5.0 5.0 0.7 0.3 0.7 FREE RELEASE 3 EX3 0.02 0.20 0.25 5.0 5.0 0.0 0.0 0.0 FREE RELEASE 5-22-19 COFC FLOW.xls Interwest Consulting Group PROPOSED DRAINAGE SUMMARY TABLE Design Tributary Area C (2 & 10) C (100) tc (10) tc (100) Q(2)tot Q(10)tot Q(100)tot Sub-basin REMARKS Point (ac) (min) (min) (cfs) (cfs) (cfs) a A 0.18 0.88 1.00 5.0 5.0 0.4 0.8 1.8 UNDERGROUND DETENTION AND WQ b B 0.51 0.77 0.96 5.0 5.0 1.1 1.9 4.9 UNDERGROUND DETENTION AND WQ c C 0.05 0.92 1.00 5.0 5.0 0.1 0.2 0.5 FREE RELEASE d D 0.06 0.35 0.44 5.0 5.0 0.1 0.1 0.3 FREE RELEASE 5-22-19 COFC FLOW.xls Interwest Consulting Group RUNOFF COEFFICIENTS & % IMPERVIOUS LOCATION: Dutch Bros - Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 5/22/2019 Recommended Runoff Coefficients from Table 3.2-2 of City of Fort Collins Stormwater Criteria Manual Recommended % Impervious from Table 4.1-3 of City of Fort Collins Stormwater Criteria Manual Type B Soils Runoff % coefficient Impervious C Streets, parking lots (asphalt): 0.95 100 Sidewalks (concrete): 0.95 100 Roofs: 0.95 90 Gravel or Pavers: 0.50 40 Landscape Areas (Avg, sandy) : 0.15 2 Landscape Areas (Steep, sandy) : 0.20 2 SUBBASIN TOTAL TOTAL ROOF PAVED PAVERS SIDEWALK LANDSCAPE RUNOFF % DESIGNATION AREA AREA AREA AREA AREA AREA AREA COEFF. Impervious REMARKS (ac.) (sq.ft) (sq.ft) (sq.ft) (sq.ft) (sq.ft) (sq.ft) (C) EXISTING EX1 0.71 31,076 2,833 18,706 0 2,832 6,706 0.79 78 EX2 0.07 2,919 0 2,919 0 0 0 0.95 100 EX3 0.02 771 0 0 0 0 771 0.20 2 EX TOTAL 0.80 34,767 2,833 21,625 0 2,832 7,477 0.79 78 PROPOSED A 0.18 7,692 1,034 4,529 0 1,427 701 0.88 90 B 0.51 22,355 2,085 12,637 0 2,308 5,326 0.77 76 C 0.05 2,142 0 1,456 0 591 95 0.92 96 D 0.06 2,578 0 0 0 511 2,067 0.35 21 TOTAL 0.80 34,768 3,119 18,622 0 4,838 8,189 0.77 76 Equations A & B %I WEIGHTED= 79 A & B TOTAL AREA= 0.69 30,047 - Calculated C coefficients & % Impervious are area weighted A & B WEIGHTED C= 0.80 C = Σ (Ci Ai) / At Total Proposed Impervious Area= 26,579 Ci = runoff coefficient for specific area, Ai Total Existing Impervious Area= 27,290 Ai = areas of surface with runoff coefficient of Ci n = number of different surfaces to consider At = total area over which C is applicable; the sum of all Ai's 5-22-19 COFC FLOW.xls Interwest Consulting Group STANDARD FORM SF-2 TIME OF CONCENTRATION - 2 and 10 YR LOCATION: Dutch Bros - Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 5/22/2019 2 and 10-yr storm Cf = 1.00 from Table RO-12 of City of Fort Collins Stormwater Code, Volume I SUB-BASIN INITIAL /OVERLAND TRAVEL TIME / GUTTER OR CHANNEL FLOW tc CHECK FINAL REMARKS DATA TIME (ti) (tt) (URBANIZED BASIN) tc DESIGN SUBBASIN(s) Area C Length Slope ti Length Slope n Vel. tt tc = Total L tc=(l/180)+10 PONIT (ac) (ft) (%) (min) (ft) (%) Manning (ft/s) (min) ti + tt (ft) (min) (min) (1) (2) (3) (4) (5) (6) (7) (8) rough. (9) (10) (11) (12) (13) (14) 1 EX1 0.71 0.79 10 2.0 1.5 260 2.0 0.012 3.8 1.1 2.6 270 11.5 5.0 2 EX2 0.07 0.95 10 2.0 0.7 0 2.0 0.012 3.8 0.0 0.7 10 10.1 5.0 3 EX3 0.02 0.20 10 2.0 4.2 0 2.0 0.012 3.8 0.0 4.2 10 10.1 5.0 a A 0.18 0.88 10 2.0 1.0 190 2.0 0.012 3.8 0.8 1.9 200 11.1 5.0 b B 0.51 0.77 74 4.0 3.3 174 0.9 0.012 2.5 1.2 4.5 248 11.4 5.0 c C 0.05 0.92 10 2.0 0.9 0 0.9 0.012 2.5 0.0 0.9 10 10.1 5.0 d D 0.06 0.35 10 2.0 3.5 0 0.9 0.012 2.5 0.0 3.5 10 10.1 5.0 EQUATIONS: tc = ti + tt ti = [1.87 (1.1 - CCf ) L0.5 ] / S 1/3 tt = L/Vel. Velocity from Manning's Equation with R=0.1 (corresponds to Figure 3-3 of City of Fort Collins Design Manual) final tc = minimum of ti + tt and urbanized basin check min. tc = 5 min. due to limits of IDF curves 5-22-19 COFC FLOW.xls Interwest Consulting Group STANDARD FORM SF-2 TIME OF CONCENTRATION - 100 YR LOCATION: Dutch Bros - Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 5/22/2019 100-yr storm Cf = 1.25 from Table RO-12 of City of Fort Collins Stormwater Code, Volume I SUB-BASIN INITIAL /OVERLAND TRAVEL TIME / GUTTER OR CHANNEL FLOW tc CHECK FINAL REMARKS DATA TIME (ti) (tt) (URBANIZED BASIN) tc DESIGN SUBBASIN(s) Area C C*Cf Length Slope ti Length Slope n Vel. tt tc = Total L tc=(l/180)+10 PONIT (ac) (ft) (%) (min) (ft) (%) Manning (ft/s) (min) ti + tt (ft) (min) (min) (1) (2) (3) (4) (5) (6) (7) (8) rough. (9) (10) (11) (12) (13) (14) 1 EX1 0.71 0.79 0.99 10 2.0 0.5 260 2.0 0.012 3.8 1.1 1.7 270 11.5 5.0 2 EX2 0.07 0.95 1.00 10 2.0 0.5 0 2.0 0.012 3.8 0.0 0.5 10 10.1 5.0 3 EX3 0.02 0.20 0.25 10 2.0 4.0 0 2.0 0.012 3.8 0.0 4.0 10 10.1 5.0 a A 0.18 0.88 1.00 10 2.0 0.5 190 2.0 0.012 3.8 0.8 1.3 200 11.1 5.0 b B 0.51 0.77 0.96 74 4.0 1.4 174 0.9 0.012 2.5 1.2 2.5 248 11.4 5.0 c C 0.05 0.92 1.00 10 2.0 0.5 0 0.9 0.012 2.5 0.0 0.5 10 10.1 5.0 d D 0.06 0.35 0.44 10 2.0 3.1 0 0.9 0.012 2.5 0.0 3.1 10 10.1 5.0 EQUATIONS: tc = ti + tt ti = [1.87 (1.1 - CCf ) L0.5 ] / S 1/3 tt = L/Vel. Velocity from Manning's Equation with R=0.1 (corresponds to Figure 3-3 of City of Fort Collins Design Manual) final tc = minimum of ti + tt and urbanized basin check min. tc = 5 min. due to limits of IDF curves 5-22-19 COFC FLOW.xls Interwest Consulting Group RATIONAL METHOD PEAK RUNOFF (City of Fort Collins, 2-Yr Storm) LOCATION: Dutch Bros - Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 5/22/2019 2 yr storm, Cf = 1.00 DIRECT RUNOFF CARRY OVER TOTAL REMARKS Design Tributary A C Cf tc i Q (2) from Q (2) Q(2)tot Sub-basin Design Point (ac) (min) (in/hr) (cfs) Point (cfs) (cfs) 1 EX1 0.71 0.79 5.0 2.85 1.6 1.6 2 EX2 0.07 0.95 5.0 2.85 0.2 0.2 3 EX3 0.02 0.20 5.0 2.85 0.0 0.0 a A 0.18 0.88 5.0 2.85 0.4 0.4 b B 0.51 0.77 5.0 2.85 1.1 1.1 c C 0.05 0.92 5.0 2.85 0.1 0.1 d D 0.06 0.35 5.0 2.85 0.1 0.1 Q = Cf C iA Q = peak discharge (cfs) C = runoff coefficient Cf = frequency adjustment factor i = rainfall intensity (in/hr) from City of Fort Collins IDF curve A = drainage area (acres) i = 24.221 / (10+ tc) 0.7968 5-22-19 COFC FLOW.xls Interwest Consulting Group RATIONAL METHOD PEAK RUNOFF (City of Fort Collins, 10-Yr Storm) LOCATION: Dutch Bros - Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 5/22/2019 10 yr storm, Cf = 1.00 DIRECT RUNOFF CARRY OVER TOTAL REMARKS Design Tributary A C Cf tc i Q (10) from Q (10) Q(10)tot Sub-basin Design Point (ac) (min) (in/hr) (cfs) Point (cfs) (cfs) 1 EX1 0.71 0.79 5.0 4.87 2.7 2.7 2 EX2 0.07 0.95 5.0 4.87 0.3 0.3 3 EX3 0.02 0.20 5.0 4.87 0.0 0.0 a A 0.18 0.88 5.0 4.87 0.8 0.8 b B 0.51 0.77 5.0 4.87 1.9 1.9 c C 0.05 0.92 5.0 4.87 0.2 0.2 d D 0.06 0.35 5.0 4.87 0.1 0.1 Q = Cf C iA Q = peak discharge (cfs) C = runoff coefficient Cf = frequency adjustment factor i = rainfall intensity (in/hr) from City of Fort Collins IDF curve A = drainage area (acres) i = 41.44 / (10+ tc)0.7974 5-22-19 COFC FLOW.xls Interwest Consulting Group RATIONAL METHOD PEAK RUNOFF (City of Fort Collins, 100-Yr Storm) LOCATION: Dutch Bros - Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 5/22/2019 100 yr storm, Cf = 1.25 DIRECT RUNOFF CARRY OVER TOTAL REMARKS Des. Area A C Cf tc i Q (100) from Q (100) Q(100)tot Design Point Design. (ac) (min) (in/hr) (cfs) Point (cfs) (cfs) 1 EX1 0.71 0.99 5.0 9.95 7.0 7.0 2 EX2 0.07 1.00 5.0 9.95 0.7 0.7 3 EX3 0.02 0.25 5.0 9.95 0.0 0.0 a A 0.18 1.00 5.0 9.95 1.8 1.8 b B 0.51 0.96 5.0 9.95 4.9 4.9 c C 0.05 1.00 5.0 9.95 0.5 0.5 d D 0.06 0.44 5.0 9.95 0.3 0.3 Q = C iA Q = peak discharge (cfs) C = runoff coefficient i = rainfall intensity (in/hr) from City of Fort Collins IDF curve A = drainage area (acres) i = 84.682 / (10+ tc)0.7975 5-22-19 COFC FLOW.xls City of Fort Collins Stormwater Criteria Manual C APPENDIX C HYDRAULIC CALCULATIONS (PROVIDED AT FINAL) D APPENDIX D WATER QUALITY AND LID INFORMATION Project Name: Dutch Bros Coffee - Kensington Project Number: 1380-165-00 Company: INTERWEST CONSULTING GROUP Designer: ES Date: 6/4/2019 1. Basin Storage Volume A) Tributary Area's Imperviousness Ratio (i=Ia/100) Ia = 79 % i = 0.79 B) Contributing Watershed Area (Area) A = 0.69 acres C) Water Quality Capture Volume (WQCV) WQCV = 0.257749 watershed inches (WQCV = a * (0.91 * i3 - 1.19 * i2 + 0.78i) ) where a=0.80 for 12 hr drain time D) Design Volume: Vol = WQCV/12 * Area * 1.2 Vol. = 0.018 ac-ft 774.7013 cf LOCATION: Dutch Bros. Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 6/4/2019 A B C D E F G H I J K WQCV (12 Hr.) WQ Flow (1/2 Q2) Chamber Type Single Chamber Release Rate Through Fabric* Volume in bottom 6" of one Chamber Min Chambers for WQ Flow Through Fabric Chambers Provided Actual Release Rate Thru Fabric Required Storage Volume by FAA Method with Qin=B and Q out=H Min Number of Chambers (Bottom 6") for FAA Release Volume in Bottom 6" of Isolator Rows to be Removed from Detention Volume cf cfs cfs cf (B/D) (G*D) cfs CF (i/e) (G*H) 775 0.7 MC3500 0.036 23 19 19 0.684 33 2 437 * - Single Chamber = 77"x86" = 46 SF FABRIC Fabric Release @ 0.35 gal/min/SF = 16 gal/min/chamber 16 gal/min = 0.036 cfs Isolator Row Volume Check Interwest Consulting Group DETENTION VOLUME CALCULATIONS Rational Volumetric (FAA) Method ISOLATOR ROW LOCATION: Dutch Bros. Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 6/4/2019 Equations: Area trib. to pond = 0.69 acre Developed flow = QD = CIA C (2) = 0.80 Vol. In = Vi = T C I A = T QD Developed C A = 0.6 acre Vol. Out = Vo =K QPO T Release rate, QPO = 0.6800 cfs storage = S = Vi - Vo K = 1 (from fig 2.1) Rainfall intensity from City of Fort Collins IDF Curve with updated (3.67") rainfall Storm Rainfall QD Vol. In Vol. Out Storage Storage Duration, T Intensity, I (cfs) Vi Vo S S (min) (in/hr) (ft 3 ) (ft 3 ) (ft 3 ) (ac-ft) 5 1.43 0.8 237 204 33 0.00 10 1.11 0.6 368 408 -40 0.00 20 0.81 0.4 537 816 -279 -0.01 30 0.65 0.4 646 1224 -578 -0.01 40 0.54 0.3 715 1632 -917 -0.02 50 0.46 0.3 762 2040 -1278 -0.03 60 0.41 0.2 815 2448 -1633 -0.04 70 0.0 0 2856 -2856 -0.07 80 0.0 0 3264 -3264 -0.07 90 0.0 0 3672 -3672 -0.08 100 0.0 0 4080 -4080 -0.09 110 0.0 0 4488 -4488 -0.10 120 0.0 0 4896 -4896 -0.11 Provided Volume: 33 ft 3 0.001 acre-ft 6-4-19 Detention - isolator row.xls,FAA-100yr Impervious Area 26,579 sf Required Minimum Impervious Area to be Treated 19,934 sf Treatment - Underground WQ System 26,579 sf Total impervious Area Treated 26,579 sf Actual % of Impervious Area On-Site Treated by LID 100 % 75% On-Site Treatment by LID Requirement LID Table E APPENDIX E DETENTION INFORMATION EXISTING PARKING LOT - Stage/Storage - Surface Water LOCATION: Dutch Bros. Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es SUBMITTED BY: INTERWEST CONSULTING GROUP DATE: 5/23/2019 V = 1/3 d ( A + B + sqrt(A*B)) where V = volume between contours, ft3 d = depth between contours, ft A = surface area of contour EXISTING PARKING LOT DETENTION Surface Incremental Total Stage Area Storage Storage (ft) (ft2) (cft) (cft) 35.7 0 35.8 11 0 0 35.9 93 5 5 36.0 347 21 26 36.1 823 57 82 36.2 1367 108 191 36.3 2114 173 363 100-yr WSEL- 36.4 3077 258 621 SPILL 36.5 5-22-19 existing Detention.xls Interwest Consulting Group DETERMINE RELEASE RATE BASED ON PARKING LOT DETENTION VOLUME Rational Volumetric (FAA) Method 100-Year Event LOCATION: Dutch Bros. Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 5/23/2019 Equations: Area trib. to pond = 0.71 acre Developed flow = QD = CIA C (100) = 0.99 Vol. In = Vi = T C I A = T QD Developed C A = 0.7 acre Vol. Out = Vo =K QPO T EX Release rate, QPO = 5.00 cfs storage = S = Vi - Vo K = 1 (from fig 2.1) Rainfall intensity from City of Fort Collins IDF Curve with updated (3.67") rainfall Storm Rainfall QD Vol. In Vol. Out Storage Storage Duration, T Intensity, I (cfs) Vi Vo S S (min) (in/hr) (ft 3 ) (ft 3 ) (ft 3 ) (ac-ft) 5 9.95 7.0 2098 1500 598 0.01 10 7.77 5.5 3275 3000 275 0.01 20 5.62 4.0 4741 6000 -1259 -0.03 30 4.47 3.1 5653 9000 -3347 -0.08 40 3.74 2.6 6309 12000 -5691 -0.13 50 3.23 2.3 6819 15000 -8181 -0.19 60 2.86 2.0 7236 18000 -10764 -0.25 70 2.57 1.8 7590 21000 -13410 -0.31 80 2.34 1.6 7896 24000 -16104 -0.37 90 2.15 1.5 8167 27000 -18833 -0.43 100 1.99 1.4 8411 30000 -21589 -0.50 110 1.86 1.3 8631 33000 -24369 -0.56 120 1.75 1.2 8834 36000 -27166 -0.62 Available Storage Volume: 598 ft 3 0.014 acre-ft 5-22-19 existing Detention.xls,FAA-100yr Interwest Consulting Group DETENTION VOLUME CALCULATIONS Rational Volumetric (FAA) Method 100-Year Event LOCATION: Dutch Bros. Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: es DATE: 6/4/2019 Equations: Area trib. to pond = 0.69 acre Developed flow = QD = CIA C (100) = 1.00 Vol. In = Vi = T C I A = T QD Developed C A = 0.7 acre Vol. Out = Vo =K QPO T PROP Release rate, QPO = 0.4 cfs storage = S = Vi - Vo K = 1 (from fig 2.1) Rainfall intensity from City of Fort Collins IDF Curve with updated (3.67") rainfall Storm Rainfall QD Vol. In Vol. Out Storage Storage Duration, T Intensity, I (cfs) Vi Vo S S (min) (in/hr) (ft 3 ) (ft 3 ) (ft 3 ) (ac-ft) 5 9.95 6.9 2060 132 1928 0.04 10 7.72 5.3 3196 264 2932 0.07 20 5.60 3.9 4637 528 4109 0.09 30 4.52 3.1 5614 792 4822 0.11 40 3.74 2.6 6193 1056 5137 0.12 50 3.23 2.2 6686 1320 5366 0.12 60 2.86 2.0 7104 1584 5520 0.13 70 2.59 1.8 7506 1848 5658 0.13 80 2.38 1.6 7883 2112 5771 0.13 90 2.21 1.5 8234 2376 5858 0.13 100 2.06 1.4 8528 2640 5888 0.14 110 1.94 1.3 8835 2904 5931 0.14 120 1.84 1.3 9141 3168 5973 0.14 Required Storage Volume: 5973 ft 3 WQCV: 774.7 ft 3 0.137 acre-ft 0.018 acre-ft 6-4-19 Detention.xls,FAA-100yr Parking Lot Detention - Stage/Storage - Surface Water LOCATION: Dutch Bros. Kensington PROJECT NO: 1380-165-00 COMPUTATIONS BY: mpo SUBMITTED BY: INTERWEST CONSULTING GROUP DATE: 6/4/2019 V = 1/3 d ( A + B + sqrt(A*B)) where V = volume between contours, ft3 d = depth between contours, ft A = surface area of contour PARKING LOT DETENTION Surface Incremental Total Stage Area Storage Storage (ft) (ft2) (cft) (cft) 35.7 0 35.8 16 1 35.9 83 5 5 36.0 214 14 19 36.1 435 32 51 Spill Over Curb 36.2 774 60 110 6-4-19 Detention.xls Project: Chamber Model - MC-3500 Units - Imperial Number of Chambers - 28 Number of End Caps - 6 Voids in the stone (porosity) - 40 % Base of STONE Elevation - 28.80 ft Amount of Stone Above Chambers - 12 in Amount of Stone Below Chambers - 15 in Area of system - 1819 sf Min. Area - Height of System Incremental Single Chamber Incremental Single End Cap Incremental Chambers Incremental End Cap Incremental Stone Incremental Ch, EC and Stone Cumulative System Elevation (inches) (cubic feet) (cubic feet) (cubic feet) (cubic feet) (cubic feet) (cubic feet) (cubic feet) (feet) 72 0.00 0.00 0.00 0.00 60.63 60.63 6266.55 34.80 71 0.00 0.00 0.00 0.00 60.63 60.63 6205.92 34.72 70 0.00 0.00 0.00 0.00 60.63 60.63 6145.29 34.63 69 0.00 0.00 0.00 0.00 60.63 60.63 6084.65 34.55 68 0.00 0.00 0.00 0.00 60.63 60.63 6024.02 34.47 67 0.00 0.00 0.00 0.00 60.63 60.63 5963.39 34.38 66 0.00 0.00 0.00 0.00 60.63 60.63 5902.75 34.30 65 0.00 0.00 0.00 0.00 60.63 60.63 5842.12 34.22 64 0.00 0.00 0.00 0.00 60.63 60.63 5781.49 34.13 63 0.00 0.00 0.00 0.00 60.63 60.63 5720.85 34.05 62 0.00 0.00 0.00 0.00 60.63 60.63 5660.22 33.97 61 0.00 0.00 0.00 0.00 60.63 60.63 5599.59 33.88 60 0.06 0.00 1.63 0.00 59.98 61.61 5538.95 33.80 59 0.19 0.02 5.43 0.14 58.40 63.98 5477.35 33.72 58 0.29 0.04 8.23 0.23 57.25 65.71 5413.36 33.63 57 0.40 0.05 11.30 0.31 55.99 67.60 5347.66 33.55 56 0.69 0.07 19.24 0.41 52.77 72.42 5280.06 33.47 55 1.03 0.09 28.79 0.53 48.90 78.23 5207.64 33.38 54 1.25 0.11 34.99 0.64 46.38 82.01 5129.41 33.30 53 1.42 0.13 39.82 0.76 44.40 84.98 5047.40 33.22 52 1.57 0.14 44.05 0.87 42.67 87.58 4962.42 33.13 51 1.71 0.16 47.80 0.98 41.12 89.90 4874.84 33.05 50 1.83 0.18 51.20 1.09 39.72 92.01 4784.94 32.97 49 1.94 0.20 54.26 1.20 38.45 93.91 4692.93 32.88 48 2.04 0.22 57.14 1.31 37.25 95.70 4599.02 32.80 47 2.13 0.23 59.77 1.41 36.16 97.34 4503.31 32.72 46 2.22 0.25 62.28 1.50 35.12 98.90 4405.97 32.63 45 2.31 0.27 64.59 1.59 34.16 100.34 4307.07 32.55 44 2.38 0.28 66.77 1.68 33.25 101.71 4206.73 32.47 43 2.46 0.29 68.85 1.76 32.39 103.00 4105.02 32.38 42 2.53 0.31 70.79 1.85 31.58 104.21 4002.02 32.30 41 2.59 0.32 72.62 1.93 30.81 105.36 3897.80 32.22 40 2.66 0.33 74.37 2.01 30.08 106.46 3792.44 32.13 SHEET OF DATE: PROJECT #: DRAWN: CHECKED: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS. 4640 TRUEMAN BLVD HILLIARD, OH 43026 1-800-733-7473 ADVANCED DRAINAGE SYSTEMS, INC. R REV DRW CHK DESCRIPTION Tool --- 70 NIWOOD ROAD, SUTIE 3 | ROCKY HLIL | CT | 06067 860-529-8188 |888-892-2694 | WWW.STORMTECH.COM Detention Retention Water Quality ACCEPTABLE FILL MATERIALS: STORMTECH MC-3500 CHAMBER SYSTEMS PLEASE NOTE: 1. THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE". 2. STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 9" (230 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. 3. WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS. NOTES: 1. MC-3500 CHAMBERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F2418 "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 2. MC-3500 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 3. "ACCEPTABLE FILL MATERIALS" TABLE ABOVE PROVIDES MATERIAL LOCATIONS, DESCRIPTIONS, GRADATIONS, AND COMPACTION REQUIREMENTS FOR FOUNDATION, EMBEDMENT, AND FILL MATERIALS. 4. THE "SITE DESIGN ENGINEER" REFERS TO THE ENGINEER RESPONSIBLE FOR THE DESIGN AND LAYOUT OF THE STORMTECH CHAMBERS FOR THIS PROJECT. 5. THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. 6. PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. 7. ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION. MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT D FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. N/A PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PREPARATION REQUIREMENTS. C INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 24" (600 mm) ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT SUBBASE MAY BE A PART OF THE 'C' LAYER. SHEET OF DATE: PROJECT #: DRAWN: CHECKED: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS. 4640 TRUEMAN BLVD HILLIARD, OH 43026 1-800-733-7473 ADVANCED DRAINAGE SYSTEMS, INC. R REV DRW CHK DESCRIPTION Tool --- 70 NIWOOD ROAD, SUTIE 3 | ROCKY HLIL | CT | 06067 860-529-8188 |888-892-2694 | WWW.STORMTECH.COM Detention Retention Water Quality INSPECTION & MAINTENANCE STEP 1) INSPECT ISOLATOR ROW FOR SEDIMENT A. INSPECTION PORTS (IF PRESENT) A.1. REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN A.2. REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED A.3. USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG A.4. LOWER A CAMERA INTO ISOLATOR ROW FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL) A.5. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. B. ALL ISOLATOR ROWS B.1. REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW B.2. USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW THROUGH OUTLET PIPE i) MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY ii) FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE B.3. IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. STEP 2) CLEAN OUT ISOLATOR ROW USING THE JETVAC PROCESS A. A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED B. APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN C. VACUUM STRUCTURE SUMP AS REQUIRED STEP 3) REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS. STEP 4) INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM. NOTES 1. INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS. 2. CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY. MC-3500 CHAMBER 18" (450 mm) MIN WIDTH CONCRETE SLAB 8" (200 mm) MIN THICKNESS PAVEMENT FLEXSTORM CATCH IT PART# 6212NYFX WITH USE OF OPEN GRATE 12" (300 mm) NYLOPLAST INLINE DRAIN BODY W/SOLID HINGED COVER OR GRATE PART# 2712AG06N SOLID COVER: 1299CGC GRATE: 1299CGS CONCRETE COLLAR NOT REQUIRED FOR UNPAVED APPLICATIONS 6" (150 mm) INSERTA TEE SHEET OF DATE: PROJECT #: DRAWN: CHECKED: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS. 4640 TRUEMAN BLVD HILLIARD, OH 43026 1-800-733-7473 ADVANCED DRAINAGE SYSTEMS, INC. R REV DRW CHK DESCRIPTION Tool --- 70 NIWOOD ROAD, SUTIE 3 | ROCKY HLIL | CT | 06067 860-529-8188 |888-892-2694 | WWW.STORMTECH.COM Detention Retention Water Quality UNDERDRAIN DETAIL NTS A A B B SECTION A-A SECTION B-B NUMBER AND SIZE OF UNDERDRAINS PER SITE DESIGN ENGINEER 4" (100 mm) TYP FOR SC-310 SYSTEMS 6" (150 mm) TYP FOR SC-740, DC-780, MC-3500 & MC-4500 SYSTEMS OUTLET MANIFOLD STORMTECH END CAP STORMTECH CHAMBERS STORMTECH CHAMBER STORMTECH END CAP DUAL WALL PERFORATED HDPE UNDERDRAIN ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE FOUNDATION STONE BENEATH CHAMBERS FOUNDATION STONE BENEATH CHAMBERS PART # STUB B C MC3500IEPP06T 6" (150 mm) 33.21" (844 mm) --- MC3500IEPP06B --- 0.66" (17 mm) MC3500IEPP08T 8" (200 mm) 31.16" (791 mm) --- MC3500IEPP08B --- 0.81" (21 mm) MC3500IEPP10T 10" (250 mm) 29.04" (738 mm) --- MC3500IEPP10B --- 0.93" (24 mm) SHEET OF DATE: PROJECT #: DRAWN: CHECKED: THIS DRAWING HAS BEEN PREPARED BASED ON INFORMATION PROVIDED TO ADS UNDER THE DIRECTION OF THE SITE DESIGN ENGINEER OR OTHER PROJECT REPRESENTATIVE. THE SITE DESIGN ENGINEER SHALL REVIEW THIS DRAWING PRIOR TO CONSTRUCTION. IT IS THE ULTIMATE RESPONSIBILITY OF THE SITE DESIGN ENGINEER TO ENSURE THAT THE PRODUCT(S) DEPICTED AND ALL ASSOCIATED DETAILS MEET ALL APPLICABLE LAWS, REGULATIONS, AND PROJECT REQUIREMENTS. 4640 TRUEMAN BLVD HILLIARD, OH 43026 1-800-733-7473 ADVANCED DRAINAGE SYSTEMS, INC. R REV DRW CHK DESCRIPTION Tool --- 70 NIWOOD ROAD, SUTIE 3 | ROCKY HLIL | CT | 06067 860-529-8188 |888-892-2694 | WWW.STORMTECH.COM Detention Retention Water Quality MC-SERIES END CAP INSERTION DETAIL NTS NOTE: MANIFOLD STUB MUST BE LAID HORIZONTAL FOR A PROPER FIT IN END CAP OPENING. 12" (300 mm) MIN SEPARATION 12" (300 mm) MIN INSERTION MANIFOLD HEADER MANIFOLD STUB STORMTECH END CAP 12" (300 mm) MIN SEPARATION 12" (300 mm) MIN INSERTION MANIFOLD HEADER MANIFOLD STUB 6 6 Dutch Bro - MC3500 Option Denver 06/06/2019 EF F APPENDIX F SOILS INFO AND REFERENCE MATERIALS Hydrologic Soil Group—Larimer County Area, Colorado (Dutch Bros. Kensington) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 4/3/2019 Page 1 of 4 4485980 4485990 4486000 4486010 4486020 4486030 4486040 4485980 4485990 4486000 4486010 4486020 4486030 4486040 493360 493370 493380 493390 493400 493410 493420 493430 493440 493450 493460 493470 493360 493370 493380 493390 493400 493410 493420 493430 493440 493450 493460 493470 40° 31' 30'' N 105° 4' 42'' W 40° 31' 30'' N 105° 4' 37'' W 40° 31' 28'' N 105° 4' 42'' W 40° 31' 28'' N 105° 4' 37'' W N Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS84 0 25 50 100 150 Feet 0 5 10 20 30 Meters Map Scale: 1:515 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Rating Polygons A A/D B B/D C C/D D Not rated or not available Soil Rating Lines A A/D B B/D C C/D D Not rated or not available Soil Rating Points A A/D B B/D C C/D D Not rated or not available Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as Hydrologic Soil Group Map unit symbol Map unit name Rating Acres in AOI Percent of AOI 4 Altvan-Satanta loams, 3 to 9 percent slopes B 0.9 84.7% 74 Nunn clay loam, 1 to 3 percent slopes C 0.2 15.3% Totals for Area of Interest 1.1 100.0% Description Hydrologic soil groups are based on estimates of runoff potential. Soils are assigned to one of four groups according to the rate of water infiltration when the soils are not protected by vegetation, are thoroughly wet, and receive precipitation from long-duration storms. The soils in the United States are assigned to four groups (A, B, C, and D) and three dual classes (A/D, B/D, and C/D). The groups are defined as follows: Group A. Soils having a high infiltration rate (low runoff potential) when thoroughly wet. These consist mainly of deep, well drained to excessively drained sands or gravelly sands. These soils have a high rate of water transmission. Group B. Soils having a moderate infiltration rate when thoroughly wet. These consist chiefly of moderately deep or deep, moderately well drained or well drained soils that have moderately fine texture to moderately coarse texture. These soils have a moderate rate of water transmission. Group C. Soils having a slow infiltration rate when thoroughly wet. These consist chiefly of soils having a layer that impedes the downward movement of water or soils of moderately fine texture or fine texture. These soils have a slow rate of water transmission. Group D. Soils having a very slow infiltration rate (high runoff potential) when thoroughly wet. These consist chiefly of clays that have a high shrink-swell potential, soils that have a high water table, soils that have a claypan or clay layer at or near the surface, and soils that are shallow over nearly impervious material. These soils have a very slow rate of water transmission. If a soil is assigned to a dual hydrologic group (A/D, B/D, or C/D), the first letter is for drained areas and the second is for undrained areas. Only the soils that in their natural condition are in group D are assigned to dual classes. Rating Options Aggregation Method: Dominant Condition Hydrologic Soil Group—Larimer County Area, Colorado Dutch Bros. Kensington Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 4/3/2019 Page 3 of 4 Component Percent Cutoff: None Specified Tie-break Rule: Higher Hydrologic Soil Group—Larimer County Area, Colorado Dutch Bros. Kensington Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 4/3/2019 Page 4 of 4 USGS The National Map: Orthoimagery. Data refreshed October, 2017. National Flood Hazard Layer FIRMette 0 250 500 1,000 1,500 2,000 Feet Ü 105°4'55.92"W 40°31'38.66"N 105°4'18.47"W 40°31'11.31"N SEE FIS REPORT FOR DETAILED LEGEND AND INDEX MAP FOR FIRM PANEL LAYOUT HAZARD SPECIAL AREAS FLOOD Without Zone A, V, Base A99 Flood Elevation (BFE) With BFE or Depth Zone AE, AO, AH, VE, AR Regulatory Floodway 0.of 2% 1% Annual annual Chance chance Flood flood with Hazard, average Areas depth areasdrainage of less less than than one one foot square or with mile Zone X Future ChanceAnnual Conditions Flood Hazard 1% Zone X Area Levee.to with See Reduced Notes. Flood Risk due Zone X Area with Flood Risk due to LeveeZone D NO SCREEN Area of Minimal Flood Hazard Zone X Area of Undetermined Flood Hazard Zone D Channel, Culvert, or Storm Sewer Levee, Dike, or Floodwall Cross Sections with 1% Annual Chance 17.5 Water Surface Elevation Coastal Transect Coastal Transect Baseline Profile Baseline Hydrographic Feature Base Flood Elevation Line (BFE) Effective LOMRs Limit of Study Jurisdiction Boundary Digital Data Available No Digital Data Available Unmapped This digital map flood complies maps if with it is FEMA's not void standards as described for the below. use of The accuracy basemap standards shown complies with FEMA's basemap The authoritative flood hazard NFHL information web services is derived provided directly by FEMA. from This the map was reflectnot exported changes on or 4/amendments 3/2019 at 2:50:subsequent 46 PM and to this does date and time. becomeor The superseded NFHL and effective by new data information over time. may change This elementsmap map image do not is appear: void if basemap the one or imagery, more of flood the following zone labels, legend, FIRM panel scale number, bar, map and creation FIRM effective date, community date. Map identifiers,images for unmapped regulatoryfor purposes. and unmodernized areas cannot be used Legend OTHER FLOOD AREAS HAZARD OF OTHER AREAS STRGUECNTUERREASL FEATURES OTHER MAP PANELS 8 1:6,000 B 20.2 The point pin selected displayed by the on the user map and is does an approximate not represent an authoritative property location. ✁ ✂ ✄ ☎ ✆ ✝ ✄ ✞ ✞ ☎ ✆ ✟ ✠ ✆ ✡ ☎ ✟ ☛ ☞ ✌ ✍ ✂ ✄ ✟ ☎ ✎ ✆ ☞ ✝ ✂ ✠ ✏ ✍ ✠ ✆ ✑ ☛ ✑ ✍ ✂ ✒ ✠ ✖ ✕ ✓ ✔ ✔ ✔ ✓ ✓ ✓ ✓ ✓ ✓ ✙ ✘ ✗ ✔ ✔ ✔ ✓ ✓ ✓ ✓ ✓ ✓ ✜ ✛ ✚ ✔ ✔ ✔ ✓ ✓ ✓ ✓ ✓ ✓ ✕ ✓ ✢ ✔ ✔ ✓ ✓ ✓ ✓ ✓ ✔ ✓ ✓ ✕ ✓ ✔ ✓ ✓ ✖ ✓ ✔ ✓ ✓ ✣ ✤ ✥ ✦ ✧ ★ ✩ ✦ ✗ ✪ ✓ ✤ ✔ ✓ ✫ ✓ ✥ ✬ ✭ ✮ ✯ ✰ ✱ ✲ ✳ ✴ ✵ ✘ ✓ ✔ ✓ ✓ ✙ ✓ ✔ ✓ ✓ ✚ ✓ ✔ ✓ ✓ ✸✾✹✽✼✹✸✻✻✷✺✹✸✷✶ ❁❀✿✼ ❄ ❄❇ ❋ ❃❂ ❆❅ ❊❉❈ ✖ ● ❍ ■ ❏ ❑ ▲ ▼ ◆ ❑ ❖ ✕ ✓ ● ❍ ■ ❏ ❑ ▲ ▼ ◆ ❑ ❖ ✕ ✓ ✓ ● ❍ ■ ❏ ❑ ▲ ▼ ◆ ❑ ❖  )LJXUH5$±&LW\RI)RUW&ROOLQV 5DLQIDOO,QWHQVLW\±'XUDWLRQ±)UHTXHQF\&XUYHV & ❴ ❴ ✈ ❵ ❛ ❛  ❜ ✇ P ❝ ◗ ❞ r ❘ ❡ ♦ ❙ ❢ ① ❚ ❣ ❤ ❯ ❜ ✐ ❝ ❱ ❥ ❞ ❲ ❦ ❡ ❳ ❢ ❧ ❣ ♠ ❨ ❤ ♥ ❩ ❬ ✐ ♦ ❥ ♣ ❭ ✐ ♦ ❯ q ❪ ♦ ❧ ♠ ♥ ❫ ② ±5XQRII ❧ ♥ r ♥ ❧ ♦ q ♠ ♥ ③ ♦ q r ④ q ❧ s s ♦ ♦ ② q t ♥ ✉ ② ♠ ⑤ ④ ♣ ♣ ④ ① ♠ ⑥  ❴ ❽ ⑩ ❴ r 5XQRII0HWKRGRORJLHV ② ❹ ② q ♦ ❛ ④ ❛ q q ❧ s ④ ⑧ ⑩ ⑦ ⑦ ④ r ⑧ ⑧ ① ♥ ④ ♦ ♦ ④ ② ⑤ s ♣ q ❻ ♦ ④ q ♦ ⑧ ② ❶ s ② ♦ q t s ❧ ❼ ④ ♦ ② q ❷ r ④ ② q ❷ ② ① r ⑨ ♣ s ② ④ ④ ♠ ❼ ❶ ♦ ❷ ♦ s s ♦ ⑨ ⑩ ⑨ ❧ q ② r r ⑧ ♦ q ④ ♥ ④ ♦ r ⑤ ♦ ♥ q ⑤ s s ⑨ ⑩ ❼ ♥ ♥ r ♦ ❧ ② ④ ④ ⑤ q t ⑤ ⑤ ♦ ♥ ⑤ ♦ s ④ ♦ s ⑩ ⑩ ♣ ♦ r r ❧ ♣ ♦ ❴ r t q ❽ q ② ⑧ ❿ ❾ ❹ q ④ ❧ ❧ ♦ ④ s ♥ ❼ ❿ r ⑨ ④ ⑨ ♠ ♣ ❼ ⑩ ④ ⑩ ♦ ❶ ♥ ❛ ♠ ♦ t ✉ q q q ② ⑧ ④ q r ④ ④ ⑦ ♥ ❿ ♥ ⑧ ⑨ ♦ ♦ ④ ♦ ♠ q ♠ ♦ ♣ ✉ ♦ ④ s ❺ ✉ ❶ ⑩ ➀ ❧ ❧ q ② ❧ ♦ t r s ♠ ♣ ♦ t ❧ q ♠ ⑧ q ⑧ ❿ ② q ♦ ④ q ⑧ r ♦ s ② ⑨ q s ② ♥ r ♦ ❿ ♦ ④ q ② q ⑤ ♦ ① ❷ ⑤ s ❷ ⑤ ❧ ⑩ q s s ⑧ ④ ④ ❧ r ⑩ ❸ q ❧ ⑧ ♦ r ♥ ♦ ♥ ❶ s ❺ ❹ ② ② ❧ t ❧ ⑨ r q t q ② q ⑧ ⑧ ❶ ❧ ④ ♦ ♦ ♠ s ❧ ♦ ❹ ❺ q r t ② ❧ ❿ q ♠ t ❧ ① ④ r ③ ⑨ ❧ ♠ q q s ⑧ ⑧ ② q ⑧ ♦ ❶ ② s ♦ ♦ ❻ q ♥ ♠ ② ② ❷ ⑤ s q ♦ ④ ❧ ♦ ④ ❿ s ♣ r q ♦ q ② ⑧ ♠ q ♣ ④ ♠ ♦ ❼ q q q ⑧ ❧ ⑧ ⑩ ② ♦ ♦ r q ♦ ⑧ ② ♣ r ④ t ❷ ❧ ♥ r ❷ ♥ ♦ s ② ♦ ④ q r q t ❷ ♦ ♥ s s ❴ ❧ ⑩ ➂ q ② ⑧ ➃ q ❧ ♦ ♦ ❛ ➁ ❴ ➇ ❛ ② ❴ ❴ q ✇ ⑧ ➂ ❿ ❿ ♦ ❛ ➃ s r ♦ ❛ ❽ ♦ ♠ ✇ ① ② q ④ ❿ ❧ ♣ r ♣ s s ❜ ♦ ⑩ ❝ s ♠ ♠ ⑨ ❞ ❧ ➄ ➅ ④ r ❡ ❢ ♦ s ④ ❣ s ✉ ② ⑤ ❤ ⑩ ⑤ ❧ r ⑦ ➈ ④ ❿ ② ❥ ⑧ s ② ➉ ❶ ♦ ♦ ♣ ✉ ❿ ♦ ❧ ⑨ ❽ ♠ ❻ ♣ q ② ② ④ ♦ ♥ q s ❷ ❧ ♥ ⑩ ④ ④ ♦ r s ① ♥ q ♠ ③ ② ② ⑩ q q r ④ ♦ ♥ ② s s ♥ ② ♦ ❼ ♦ ♣ ② ♣ ♥ ② ❧ ♠ r r q ② ④ ② ♠ q ❶ s ⑧ ⑤ ⑩ ♦ ♦ ④ ⑩ ♣ ♥ ♥ ♣ ♦ ④ ♦ s r ② ① ♠ q ❧ ❧ ❶ ♠ r ❼ ⑥ r ② ❶ ④ ④ ♦ ♥ ⑤ ⑤ ♦ ❹ ② ♣ ❿ ④ ❴ ❧ q ❽ ♣ ⑧ ❧ ❾ q ❧ ✈ ♦ ➁ ❼ ♠ t ♥ ♦ ❼ ② ♦ s ♠ ❛ ❧ ② ❶ ⑩ r r ⑨ ♥ ♦ ♠ ♥ q ❵ ⑩ ➃ ❹ ➃ ♦ ⑨ ➁ ♠ t ⑨ q ♦ ♠ ❹ ♦ ② ♦ ♥ s ♠ ♥ q ⑧ ④ s ④ ② ⑩ ❧ ① r ④ r ② ❶ ♥ ④ ♦ ♦ r ♣ ♠ ❽ ♥ t s q ♠ ④ ② q ♦ ❧ s r ⑩ ⑩ ② ♠ ❶ ➅ ♦ ⑩ s ② ❹ ⑨ ❧ ② r ♠ ♠ q ② ❧ ❶ r ❹ ♦ ♦ ② ➆ s ❧ ♦ r ♣ ② ② ❿ r ♠ ♣ ⑨ ♠ ④ ♥ ✉ ⑤ ♦ ♥ r ❧ ① r ♦ ❧ q q t ⑧  ⑨ ❴ q s 5DWLRQDO0HWKRG5XQRII&❧ ② ⑨ ⑩ ④ ❛ r r ♦ ④ ♠ ♠ ⑦ ⑤ ⑤ ④ ⑧ ⑤ s ❿ ④ ♦ ④ s q ⑧ ♦ s ② ⑨ ♦ ⑤ r ⑤ r ❧ q ④ ❿ t ➋ ⑤ ❧ ❷ ♦ ⑤ ❸ ♦ r ♦ ❿ ♠ q s ④ ♠ ④ ② ♦ ⑤ ♣ ⑤ ⑤ ♣ ④ ⑤ ♠ s ❧ ➅ ⑨ ❿ ❿ s ❧ s ④ ⑤ ♦ ② ② r ⑩ ❧ ❿ r q ♦ ♠ ⑩ ② ♠ ❶ RHIILFLHQWV q ④ ♦ ④ ④ r r ➆ ❹ q t q ♦ ♣ ⑧ ② ❷ r ♦ ⑨ ♦ ♠ ♠ ♥ ❴ ♦ ➋ s ④ ♥ ② ⑤ ➅ ❧ ❧ r ➄ r ➆ ② ④ ❛ ❶ r q ⑧ ♦ ❧ ♠ ♦ r ⑨ ② ❶ ❹ ❻ s ⑩ ♦ ❿ ② ② ♣ ❧ q ② ✉ q ❧ ♠ q ④ ② ♠ ➊ r ♣ ❧ ④ ③ ② ⑤ ❧ ♣ r ❧ ❿ ⑤ ❧ ❼ ② r q q ❶ ❧ ⑧ ♦ ④ ♦ q ❿ r ⑧ ♣ ♠ q ④ ② t ♥ ♠ ❧ ❷ r ♠ ♦ ❧ ❿ q ⑤ ♠ ② ⑧ ❧ ❿ r ♦ ④ ② ⑤ ❿ ❹ q ❧ ❧ ♠ ♦ ④ q ⑨ t r ♥ s ♠ ⑤ ④ ♦ ② ⑤ q ⑩ ❿ ♦ ➍ ♦ s ② ⑩ ④ ♠ t s ❧ ② q ❹ r s ❺ ♦ ♦ ♦ ♥ ④ ⑨ r ♣ ♠ ❹ ♣ ④ ♦ ❧ ② q r ♥ ♠ ♠ ➌ ♦ q ✉ r ④ ♥ ④ ♦ ④ ① ♠ r q r ❧ ✉ ⑩ ♦ ❧ ② q ⑦ ⑧ q ♦ ♦ ② ❹ s ⑤ ♣ ♣ ➄ ♦ ④ ④ ① ❻ r ❧ ➋ s r ② ❶ ➁ q ♦ ❵ ❿ ➃ ♠ ♣ ② ② ♣ ♠ ❧ r ♠ ♠ ♥ q ❧ ♠ ⑤ ❸ ❧ ❿ q ④ ⑧ ② ♣ ♦ ➁ ➁ of the version date(s) listed below. Soil Survey Area: Larimer County Area, Colorado Survey Area Data: Version 13, Sep 10, 2018 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Sep 20, 2015—Oct 21, 2017 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Hydrologic Soil Group—Larimer County Area, Colorado (Dutch Bros. Kensington) Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 4/3/2019 Page 2 of 4 MC3500IEPP12T 12" (300 mm) 26.36" (670 mm) --- MC3500IEPP12B --- 1.35" (34 mm) MC3500IEPP15T 15" (375 mm) 23.39" (594 mm) --- MC3500IEPP15B --- 1.50" (38 mm) MC3500IEPP18TC 18" (450 mm) 20.03" (509 mm) --- MC3500IEPP18BC --- 1.77" (45 mm) MC3500IEPP24TC 24" (600 mm) 14.48" (368 mm) --- MC3500IEPP24BC --- 2.06" (52 mm) MC3500IEPP30BC 30" (750 mm) --- NOMINAL CHAMBER SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH) 77.0" X 45.0" X 86.0" (1956 mm X 1143 mm X 2184 mm) CHAMBER STORAGE 109.9 CUBIC FEET (3.11 m³) MINIMUM INSTALLED STORAGE* 178.9 CUBIC FEET (5.06 m³) WEIGHT 135.0 lbs. (61.2 kg) NOMINAL END CAP SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH) 77.0" X 45.0" X 22.5" (1956 mm X 1143 mm X 571 mm) END CAP STORAGE 14.9 CUBIC FEET (0.42 m³) MINIMUM INSTALLED STORAGE* 46.0 CUBIC FEET (1.30 m³) WEIGHT 50.0 lbs. (22.7 kg) *ASSUMES 12" (305 mm) STONE ABOVE, 9" (229 mm) STONE FOUNDATION AND BETWEEN CHAMBERS, 12" (305 mm) STONE PERIMETER IN FRONT OF END CAPS AND 40% STONE POROSITY MC-3500 TECHNICAL SPECIFICATION NTS 90.0" (2286 mm) ACTUAL LENGTH 86.0" (2184 mm) INSTALLED BUILD ROW IN THIS DIRECTION NOTE: ALL DIMENSIONS ARE NOMINAL CUSTOM PRECORED INVERTS ARE AVAILABLE UPON REQUEST. INVENTORIED MANIFOLDS INCLUDE 12-24" (300-600 mm) SIZE ON SIZE AND 15-48" (375-1200 mm) ECCENTRIC MANIFOLDS. CUSTOM INVERT LOCATIONS ON THE MC-3500 END CAP CUT IN THE FIELD ARE NOT RECOMMENDED FOR PIPE SIZES GREATER THAN 10" (250 mm) THE INVERT LOCATION IN COLUMN 'B' ARE THE HIGHTEST POSSIBLE FOR THE PIPE SIZE. LOWER JOINT CORRUGATION WEB CREST CREST STIFFENING RIB VALLEY STIFFENING RIB B C 77.0" (1956 mm) 45.0" (1143 mm) 25.7" (653 mm) FOOT 77.0" (1956 mm) 45.0" (1143 mm) STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" UPPER JOINT CORRUGATION 22.5" (571 mm) INSTALLED INSERTA TEE DETAIL NTS INSERTA TEE CONNECTION CONVEYANCE PIPE MATERIAL MAY VARY (PVC, HDPE, ETC.) PLACE ADS GEOSYNTHETICS 315 WOVEN GEOTEXTILE (CENTERED ON INSERTA-TEE INLET) OVER BEDDING STONE FOR SCOUR PROTECTION AT SIDE INLET CONNECTIONS. GEOTEXTILE MUST EXTEND 6" (150 mm) PAST CHAMBER FOOT INSERTA TEE TO BE INSTALLED, CENTERED OVER CORRUGATION SECTION A-A SIDE VIEW A A DO NOT INSTALL INSERTA-TEE AT CHAMBER JOINTS NOTE: PART NUMBERS WILL VARY BASED ON INLET PIPE MATERIALS. CONTACT STORMTECH FOR MORE INFORMATION. CHAMBER MAX DIAMETER OF INSERTA TEE HEIGHT FROM BASE OF CHAMBER (X) SC-310 6" (150 mm) 4" (100 mm) SC-740 10" (250 mm) 4" (100 mm) DC-780 10" (250 mm) 4" (100 mm) MC-3500 12" (300 mm) 6" (150 mm) MC-4500 12" (300 mm) 8" (200 mm) INSERTA TEE FITTINGS AVAILABLE FOR SDR 26, SDR 35, SCH 40 IPS GASKETED & SOLVENT WELD, N-12, HP STORM, C-900 OR DUCTILE IRON (X) 5 6 Dutch Bro - MC3500 Option Denver 06/06/2019 EF PART#06N12ST35IP INSERTA TEE TO BE CENTERED ON CORRUGATION CREST MC-3500 6" INSPECTION PORT DETAIL NTS 6" (150 mm) ADS N-12 HDPE PIPE CONCRETE COLLAR SUMP DEPTH TBD BY SITE DESIGN ENGINEER (24" [600 mm] MIN RECOMMENDED) 24" (600 mm) HDPE ACCESS PIPE REQUIRED USE FACTORY PRE-CORED END CAP PART #: MC3500IEPP24BC TWO LAYERS OF ADS GEOSYNTHETICS 315WTM WOVEN GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS 8.25' (2.51 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS CATCH BASIN OR MANHOLE COVER PIPE CONNECTION TO END CAP WITH ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE MC-3500 CHAMBER MC-3500 END CAP MC-3500 ISOLATOR ROW DETAIL NTS OPTIONAL INSPECTION PORT STORMTECH HIGHLY RECOMMENDS FLEXSTORM PURE INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES 4 6 Dutch Bro - MC3500 Option Denver 06/06/2019 EF GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR PROCESSED AGGREGATE. MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS LAYER. AASHTO M145¹ A-1, A-2-4, A-3 OR AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 BEGIN COMPACTIONS AFTER 24" (600 mm) OF MATERIAL OVER THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN 12" (300 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR PROCESSED AGGREGATE MATERIALS. B EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS FROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER ABOVE. CLEAN, CRUSHED, ANGULAR STONE, NOMINAL SIZE DISTRIBUTION BETWEEN 3/4-2 INCH (20-50 mm) AASHTO M43¹ 3, 4 A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. CLEAN, CRUSHED, ANGULAR STONE, NOMINAL SIZE DISTRIBUTION BETWEEN 3/4-2 INCH (20-50 mm) AASHTO M43¹ 3, 4 PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE. ² ³ 6" (150 mm) MIN 45" (1140 mm) 24" (600 mm) MIN* 8' (2.4 m) MAX 77" (1950 mm) 12" (300 mm) TYP ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS SUBGRADE SOILS (SEE NOTE 5) PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) MC-3500 END CAP 12" (300 mm) MIN 9" (230 mm) MIN DEPTH OF STONE TO BE DETERMINED BY DESIGN ENGINEER 9" (230 mm) MIN D C B A *TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, PERIMETER STONE INCREASE COVER TO 30" (750 mm). (SEE NOTE 6) EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) NO COMPACTION REQUIRED. 3 6 Dutch Bro - MC3500 Option Denver 06/06/2019 EF 39 2.72 0.35 76.02 2.08 29.39 107.50 3685.98 32.05 38 2.77 0.36 77.60 2.16 28.73 108.49 3578.48 31.97 37 2.82 0.37 79.09 2.23 28.10 109.43 3470.00 31.88 36 2.88 0.38 80.51 2.31 27.51 110.32 3360.57 31.80 35 2.92 0.40 81.88 2.38 26.93 111.18 3250.24 31.72 34 2.97 0.41 83.16 2.45 26.39 111.99 3139.06 31.63 33 3.01 0.42 84.35 2.51 25.89 112.75 3027.06 31.55 32 3.05 0.43 85.49 2.58 25.41 113.47 2914.31 31.47 31 3.09 0.44 86.64 2.64 24.92 114.20 2800.84 31.38 30 3.13 0.45 87.66 2.70 24.49 114.85 2686.64 31.30 29 3.17 0.46 88.64 2.77 24.07 115.48 2571.79 31.22 28 3.20 0.47 89.58 2.82 23.67 116.08 2456.31 31.13 27 3.23 0.48 90.47 2.88 23.29 116.64 2340.23 31.05 26 3.26 0.49 91.32 2.94 22.93 117.19 2223.59 30.97 25 3.29 0.50 92.13 2.99 22.59 117.70 2106.40 30.88 24 3.32 0.51 92.90 3.04 22.26 118.20 1988.70 30.80 23 3.34 0.51 93.64 3.09 21.94 118.67 1870.50 30.72 22 3.37 0.52 94.32 3.13 21.65 119.11 1751.84 30.63 21 3.39 0.53 94.99 3.18 21.37 119.53 1632.73 30.55 20 3.41 0.54 95.61 3.22 21.10 119.93 1513.20 30.47 19 3.44 0.54 96.24 3.26 20.84 120.33 1393.27 30.38 18 3.46 0.55 96.82 3.30 20.59 120.70 1272.94 30.30 17 3.48 0.56 97.40 3.33 20.34 121.07 1152.23 30.22 16 3.51 0.59 98.14 3.57 19.95 121.66 1031.16 30.13 15 0.00 0.00 0.00 0.00 60.63 60.63 909.50 30.05 14 0.00 0.00 0.00 0.00 60.63 60.63 848.87 29.97 13 0.00 0.00 0.00 0.00 60.63 60.63 788.23 29.88 12 0.00 0.00 0.00 0.00 60.63 60.63 727.60 29.80 11 0.00 0.00 0.00 0.00 60.63 60.63 666.97 29.72 10 0.00 0.00 0.00 0.00 60.63 60.63 606.33 29.63 9 0.00 0.00 0.00 0.00 60.63 60.63 545.70 29.55 8 0.00 0.00 0.00 0.00 60.63 60.63 485.07 29.47 7 0.00 0.00 0.00 0.00 60.63 60.63 424.43 29.38 StormTech MC-3500 Cumulative Storage Volumes 1539 sf min. area Include Perimeter Stone in Calculations Click Here for Metric PROPOSED DRAINAGE BASIN ID DESIGN POINT PROPOSED DRAINAGE BASIN DIVIDE LINE