HomeMy WebLinkAboutLANDMARK APARTMENTS EXPANSION - FDP190002 - SUBMITTAL DOCUMENTS - ROUND 2 - REDLINED PLANS AND REPORTS (12)PROSPECT ROAD SHIELDS STREET LAKE STREET PITKIN STREET STUART STREET HOBBIT ST. SHEELY DR. HILL POND RD. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R JANUARY 2019 UTILITY PLANS FOR CONTACT INFORMATION PROJECT TEAM: The Birdsall Group 444 Mountain Avenue Berthoud, Colorado 80513 (970) 532-5891 Redwood Construction, Inc. Contact: Daniel Peress 2082 Michelson Drive, 4th Floor Irive, CA 92612 (949) 299-0875 UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER Northern Engineering Services, Inc. Danny Weber, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 ENGINEER ING N O R T H E RN ENGINEER ING N O R T H E RN PLANNER/ LANDSCAPE ARCHITECT ** The underground utility locates provided by United States Infrastructure Corporation, LLC. are based upon the best available information at the time of locating. Contractor acknowledges that it is common for underground facility owner maps to have errors and omissions of data shown. Consequently, it is the Contractor's sole responsibility to field verify the location of all utilities prior to construction, and notify the Engineer of any discrepancies found. I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All sanitary sewer, storm sewer and water line construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X T T T T T T W S S W FO FO FO 6" SS 6" SS DC DC DC DC 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 8" SS S HOBBIT STREET RIGHT OF WAY 51' RIGHT OF WAY (TO BE VACATED) X E E E E 8" W 8" W X X X X X X X X X X X X X X X X X X X X X E E W I W W W W WW WW EB FO FO FO FO FO 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS CC CC CC CC CC 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 6" SS 6" W 6" W 6" W 8" SS 8" SS 8" SS 8" SS 8" SS 8" W 8" W 8" W 8" W 8" W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X T T T T T T W W FO FO FO 6" SS 6" SS DC DC S W. PROSPECT ROAD 102' RIGHT OF WAY LOT 1 LANDMARK SUBDIVISION PUD OWNER: LANDMARK HOUSING LLC LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HUFBAURER, RUTH LOT 2 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: FONTE, STEVEN J & SARAH C LOT 1 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HOGESTAD, PER M & VEDA V LOT 6 SEAMAN SUBDIVISION OWNER: EWAN, JOHN L & YVONNE S NORTHWEST CORNER SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST X E E E E X X X X X X X X X X X X X X X X E E W W W W W WW WW FO FO FO FO FO 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS CC X X X X S S S D D WALLENBERG DRIVE STUART STREET 54' RIGHT OF WAY OWNER: LANDMARK HOUSING LLC LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: DEVORE, JANICE S. LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HANSCH, EDWARD C & DEBRA J LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X T T T T T T W W FO FO FO 6" SS 6" SS DC DC 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 8" SS S S S F F FDC FDC UD UD UD UD UD UD X E E E E 8" W 8" W X X X X X X X X X X X X X X X X E E W W W W W WW WW FO FO FO FO FO 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS CC 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 6" SS 6" W 6" W 6" W 8" SS 8" SS 8" SS 8" SS 8" SS 8" W 8" W 8" W 8" W 8" W X X X X S S S D D UD UD UD UD UD UD UD UD UD UD X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X T T T T T T W W FO FO FO 6" SS 6" SS DC DC 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W 8" SS S UD UD UD UD UD UD W. PROSPECT ROAD 102' RIGHT OF WAY LOT 1 LANDMARK SUBDIVISION PUD OWNER: LANDMARK HOUSING LLC LOT 3 ARTHER X E E E E 8" W 8" W X X X X X X X X X X X X X X X X E E W W W W W WW WW FO FO FO FO FO 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS 6" SS CC 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 6" SS 6" W 6" W 6" W 8" SS 8" SS 8" SS 8" SS 8" SS 8" W 8" W 8" W 8" W 8" W X X X X S S S D D UD UD UD UD UD UD UD UD UD UD S S FDC FDC F UD UD UD UD UD C.O. X W 8" W 8" W 8" W 8" W CONNECT TO EXISTING 8" TEE w/ TB & 8" GV (N) N:1449715.56 E:3113674.70 2" WATER METER N:1449738.81 E:3113725.25 45° BEND w/ TB N:1449724.78 E:3113674.70 45° BEND w/ TB N:1449726.90 E:3113676.82 45° BEND w/ TB N:1449726.89 45° BEND w/ TB E:3113776.78 N:1449748.05 E:3113797.95 9.22 LF 8" PVC N00°00'35"E 3.00 LF 8" PVC N45°00'35"E 99.96 LF 8" PVC S89°59'25"E 29.93 LF 8" PVC N45°00'35"E 5000 5005 5010 5015 5020 5025 5030 5035 5040 5045 5000 5005 5010 5015 5020 5025 5030 5035 5040 5045 4990 4995 5000 5005 5010 5015 5020 5025 5030 5035 4990 4995 5000 5005 5010 5015 5020 5025 5030 5035 16+25 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 178.10 LF 8" PVC @ 0.40% 94.78 LF 8" PVC @ 0.40% 37.72 LF 8" PVC @ 0.40% 16.26 LF 8" PVC @ 5.00% 46.22 LF 8" PVC @ 0.40% SSMH A7 STA 15+44.09 RIM 5024.1± INV. OUT 5016.14 (S) SSMH A5 STA 13+56.82 RIM 5015.1± INV. IN 5006.78 (N) INV. OUT 5006.58 (SW) SSMH A3 STA 12+24.32 RIM 5015.1± INV. IN 5005.85 (E) INV. OUT 5005.65 (S) SSMH A4 STA 13+19.10 RIM 5014.2± INV. IN 5006.43 (NE) INV. OUT 5006.23 (W) SSMH A2 STA 10+46.22 RIM 5013.9± INV. IN 5004.94 (N) INV. OUT 5004.74 (S) SSMH A1 STA 10+00.00 RIM 5012.4± INV. IN 5004.56 (N) INV. OUT 5004.36 (W) PROPOSED GRADE EXISTING GROUND STA. 11+29.5 START 16" CASING PIPE X X X X X X X X W S S F F FDC FDC FDC UD UD UD UD UD STMH 3-2 STA 10+71.62 N: 1449877.71 E: 3113829.31 INLET 3-2 STA 11+71.07 N: 1449877.57 E: 3113729.86 INLET 3-4 STA 12+13.98 N: 1449920.07 E: 3113727.86 RDC 3-2A INV. OUT=5018.01 (NW) FG=5022.00 BEND 3-3 STA 11+76.24 N: 1449882.33 E: 3113727.86 CONCRETE FES 3-1 STA 10+00.00 N: 1449812.35 E: 3113858.59 71.62 LF 12" HDPE @ 0.50% 99.45 LF 12" HDPE @ 0.50% 9.18 LF 6" PVC @ 2.00% 5.16 LF 8" PVC @ 1.00% 37.74 LF 8" PVC @ 1.00% 5005 5010 5015 5020 5025 5030 5035 5005 5010 5015 5020 5025 5030 5035 12+50 12+00 11+00 10+00 9+75 Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 D9 PED BRIDGE DETAILS 28 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NOTES: · BRIDGE DETAILS ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO OBTAIN STAMPED STRUCTURAL PLAN SET FROM CONTECH DIRECTLY. 2/19/19 Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 D10 PED BRIDGE DETAILS 29 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NOTES: · BRIDGE DETAILS ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR TO OBTAIN STAMPED STRUCTURAL PLAN SET FROM CONTECH DIRECTLY. 2/19/19 UD UD UD T T E E E 8" SS 8" SS 8" SS 8" SS E E X X X X X X X X X X X X X X X X X X X T T E W W W W W W WW WW ET FO FO 6" SS 6" SS 6" SS 6" SS 6" SS DC DC CC VAULT ELEC S S S S S S S S CONTROL IRR CONTROL IRR CONTROL IRR WV WV H Y D WV WV WV S WV WV WV E E E E T T T T G G G G X X X S S S S S S D D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD TRACT B YOUNG'S CREEK OWNER: CITY OF FORT COLLINS OS4 OS2 OS1 UD2 B1 OS5 OS7 A1 A2 A4 A3 A1 A2 A4 A3 B1 BFE: 5012.3 UD1 OS3 OS1 OS2 A5 A5 OS8 OS6 OS3 OS4 A6 A6 OS5 OS6 OS7 OS8 S N T BFE: 5011.53 BFE: 5012.93 INLET 1-2 CONCRETE FES 1-1 INLET 2-2A INLET 3-2 STMH 3-2 INLET 3-4 CONCRETE FES 3-1 INLET 4-2 CONCRETE FES 4-1 OUTLET 5-1 CONCRETE FES 6-1 CITY OF FORT COLLINS 100-YR FLOODWAY CITY OF FORT COLLINS 100-YR FLOODPLAIN RAIN GARDEN 1 RAIN GARDEN 3 RAIN GARDEN 4 RAIN GARDEN 2 HOBBIT STREET 54' RIGHT OF WAY W. PROSPECT ROAD 102' RIGHT OF WAY WALLENBERG DRIVE STUART STREET 54' RIGHT OF WAY LOT 1 LANDMARK SUBDIVISION PUD OWNER: LANDMARK HOUSING LLC LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: DEVORE, JANICE S. LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HANSCH, EDWARD C & DEBRA J LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HUFBAURER, RUTH LOT 2 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: FONTE, STEVEN J & SARAH C LOT 1 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HOGESTAD, PER M & VEDA V TRACT B PULSE PUD 1ST OWNER: NORTH SPRING CREEK PROPERTIES LLC LOT 6 SEAMAN SUBDIVISION OWNER: EWAN, JOHN L & YVONNE S INLET 6-2 Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC LEGEND: 5013 PROPOSED CONTOUR 93 EXISTING CONTOUR PROPERTY BOUNDARY EXISTING STORM SEWER 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE "FINAL DRAINAGE AND EROSION CONTROL REPORT FOR LANDMARK APARTMENTS EXPANSION" BY NORTHERN ENGINEERING, DATED JANUARY 25, 2019 FOR ADDITIONAL INFORMATION. NOTES: FLOW PATH DRAINAGE BASIN BUBBLE A DESIGN POINT A BASIN BOUNDARY PROPOSED STORM SEWER FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 DR1 DRAINAGE PLAN 30 NORTH DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C10 C100 2-yr Tc (min) 10-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q10 (cfs) Q100 (cfs) A1 A1 0.55 0.68 0.68 0.84 5.1 5.1 5.0 1.07 1.82 4.66 A2 A2 0.25 0.63 0.63 0.78 5.0 5.0 5.0 0.45 0.77 1.96 A3 A3 1.04 0.66 0.66 0.82 8.5 8.5 8.2 1.63 2.79 7.13 A4 A4 0.31 0.92 0.92 1.00 5.0 5.0 5.0 0.82 1.41 3.13 A5 A5 0.23 0.75 0.75 0.94 5.0 5.0 5.0 0.49 0.83 2.13 A6 A6 0.10 0.80 0.80 1.00 5.0 5.0 5.0 0.23 0.40 1.01 N UD1 0.11 0.25 0.25 0.31 5.0 5.0 5.0 0.08 0.13 0.34 B1 B1 0.32 0.79 0.79 0.99 5.0 5.0 5.0 0.71 1.21 3.10 S UD2 0.15 0.48 0.48 0.60 8.5 8.5 7.8 0.18 0.30 0.79 OS1 OS1 0.46 0.30 0.30 0.38 11.2 11.2 10.4 0.29 0.50 1.34 OS2 OS2 1.31 0.35 0.35 0.44 12.4 12.4 11.5 0.94 1.60 4.23 OS3 OS3 0.29 0.36 0.36 0.45 10.7 10.7 10.0 0.23 0.39 1.04 OS4 OS4 4.14 0.57 0.57 0.72 19.6 19.6 18.8 3.86 6.59 17.28 OS5 OS5 0.24 0.84 0.84 1.00 5.0 5.0 5.0 0.58 0.99 2.40 OS6 OS6 1.07 0.71 0.71 0.89 10.1 10.1 9.6 1.68 2.87 7.48 OS7 OS7 0.28 0.94 0.94 1.00 5.0 5.0 5.0 0.74 1.26 2.74 OS8 OS8 0.12 0.31 0.31 0.39 6.6 6.6 6.3 0.10 0.17 0.45 Incorrect Plat Title Line Over Text Spelling Spelling Spelling Spelling Spelling 2/19/19 CONCRETE FES 3-1 STA 10+00.00 INV. 5015.00 (NW) 71.62 LF 12" HDPE @ 0.50% STMH 3-2 STA 10+71.62 RIM 5021.4± INV. IN 5017.33 (W) INV. OUT 5015.36 (SE) 99.45 LF 12" HDPE @ 0.50% INLET 3-2 STA 11+71.07 RIM 5020.8± INV. IN 5017.83 (SE) INV. IN 5017.83 (NW) INV. OUT 5017.83 (E) 5.16 LF 8" PVC @ 1.00% BEND 3-3 STA 11+76.24 INV. 5017.88 (N) INV. 5017.88 (SE) 37.74 LF 8" PVC @ 1.00% INLET 3-4 STA 12+13.98 RIM 5020.1± INV. OUT 5018.26 (S) PROPOSED GRADE EXISTING GROUND 8" WATER STA.=10+91.70 TOP=5015.83 18" MIN. 100-yr HGL UD UD UD UD UD WYE 4-3 INV. IN=5009.24 (SW) INV. IN=5009.24 (NW) INV. OUT=5009.24 (NE) FG=5011.25 INLET 4-2 STA 10+40.70 N: 1449491.34 E: 3113895.92 CONCRETE FES 4-1 STA 10+00.00 N: 1449515.56 E: 3113928.63 CLEANOUT 4-3A INV. OUT=5009.28 (SE) FG=5012.01 CLEANOUT 4-4 INV. OUT=5009.28 (NE) FG=5012.00 40.70 LF 15" HDPE @ 0.50% 11.28 LF 4" PERF PVC @ 0.25% 15.91 LF 4" PERF PVC @ 0.25% 17.61 LF 4" PERF PVC @ 0.25% 4995 5000 5005 5010 5015 5020 5025 4995 5000 5005 5010 5015 5020 5025 11+00 10+00 9+50 CONCRETE FES 4-1 STA 10+00.00 INV. 5009.01 (SW) 40.70 LF 15" HDPE @ 0.50% INLET 4-2 STA 10+40.70 FL. EL 5012.0± INV. IN 5009.21 (SW) INV. OUT 5009.21 (NE) PROPOSED GRADE EXISTING GROUND 100-yr HGL 8" W UD UD UD UD UD UD UD UD UD UD FDC F S RDC 5-4A INV. OUT=5011.81 (NE) FG=5014.25 RDC 5-5 STA 11+21.92 N: 1449566.88 E: 3113785.80 WYE 5-4 STA 10+90.64 N: 1449552.70 E: 3113813.68 CLEANOUT 5-3 STA 10+35.85 N: 1449527.85 E: 3113862.51 BEND 5-2 STA 10+19.06 N: 1449515.09 E: 3113873.43 OUTLET 5-1 STA 10+00.00 N: 1449496.96 E: 3113879.33 19.06 LF 8" PVC @ 0.50% 54.79 LF 8" PVC @ 0.50% 31.28 LF 6" PVC @ 1.00% 10.76 LF 6" PVC @ 1.00% 16.79 LF 8" PVC @ 0.50% 5000 5005 5010 5015 5020 5025 5030 5000 5005 5010 5015 5020 5025 5030 11+50 11+00 10+00 9+75 OUTLET 5-1 STA 10+00.00 INV. 5011.25 (N) 19.06 LF 8" PVC @ 0.50% BEND 5-2 STA 10+19.06 INV. 5011.35 (NW) INV. 5011.35 (S) 16.79 LF 8" PVC @ 0.50% CLEANOUT 5-3 STA 10+35.85 RIM 5013.4± INV. IN 5011.43 (NW) INV. OUT 5011.43 (SE) 54.79 LF 8" PVC @ 0.50% WYE 5-4 STA 10+90.64 INV. 5011.71 (NW) INV. 5011.71 (SW) INV. 5011.71 (SE) 31.28 LF 6" PVC @ 1.00% RDC 5-5 STA 11+21.92 RIM 5013.6± INV. OUT 5012.02 (SE) PROPOSED GRADE EXISTING GROUND 100-yr HGL Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. MINIMUM COVER OF 4.5' SHALL BE MAINTAINED THROUGHOUT THE WATERLINE AND SERVICE LINE INSTALLATION. MAXIMUM ALLOWED COVER SHALL BE 6' UNLESS SPECIFICALLY APPROVED BY THE CITY. 9. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 10. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. 11. SEE SHEET D8 FOR INLET SCHEDULE AND SHEET EC3 FOR SCOURSTOP SCHEDULE. EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING TELEPHONE PEDESTAL EXISTING TREES EXISTING SANITARY SEWER PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY S PROPOSED SEWER SERVICE PROPOSED RESIDENTIAL WATER SERVICE EXISTING GAS METER W CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner KEYMAP DC DC CC ST2 PLAN AND PROFILE STORM DRAIN LINES 3-1, 4-1, & 5-1 15 PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' STORM DRAIN LINE 3-1 PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' STORM DRAIN LINE 4-1 STORM DRAIN LINE 5-1 NORTH NORTH NORTH PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 14 15 15 14 14 15 2/19/19 Line Over Text Line Over Text STA. 11+80.5 END 16" CASING PIPE STA. 11+64.2 - 5'-2" x 14'-0" ARCHED CMP. STA. 11+46.0 - 5'-2" x 14'-0" ARCHED CMP. ELEV.=5009.5 ELEV.=5009.4 STA. 10+95.34 1-1/2" WATER SERVICE STA. 13+83.12 6" FIRE LINE STA. 13+86.12 1-1/2" WATER SERVICE STA. 13+98.99 6" FIRE HYDRANT 51.0' 16" STEEL CASING PIPE 2.8'± 12" HDPE STA.=14+91.47 INV.=5017.38 8" PVC STA.=13+33.26 INV.=5012.65 TEE A6 STA 13+73.07 RIM 5008.3± INV. IN 5007.59 (N) INV. IN 5008.26 (E) INV. OUT 5007.59 (S) 171.02 LF 8" PVC @ 5.00% X E 8" W X X X X X X X X X X X X X X X X W W 8" W 8" W 8" W 8" W 8" W 8" W 8" SS 8" W S D D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD SSMH A7 STA 15+44.09 N: 1449930.12 E: 3113823.83 SSMH A5 STA 13+56.82 N: 1449743.55 E: 3113807.59 SSMH A3 STA 12+24.32 N: 1449716.90 E: 3113686.14 SSMH A4 STA 13+19.10 N: 1449716.89 E: 3113780.92 SSMH A2 STA 10+46.22 N: 1449538.81 E: 3113685.07 SSMH A1 STA 10+00.00 N: 1449493.63 E: 3113694.83 178.10 LF 8" PVC @ 0.40% 94.78 LF 8" PVC @ 0.40% 37.72 LF 8" PVC @ 0.40% 16.26 LF 8" PVC @ 5.00% 46.22 LF 8" PVC @ 0.40% S S S F F FDC FDC FDC FDC FDC F S F F UD UD UD UD UD UD C.O. C.O. 171.02 LF 8" PVC @ 5.00% TEE A6 INV. IN=5007.59 (N) INV. IN=5008.26 (E) INV. OUT=5007.59 (S) FG=5015.75 N: 1449759.75 E: 3113809.00 60.00 LF 6" PVC @ 1.00% CLEANOUT A6-1 INV. IN=5008.86 (E) INV. OUT=5008.86 (W) FG=5015.50 N: 1449757.49 E: 3113868.96 57.87 LF 6" PVC @ 1.00% CLEANOUT A6-2 INV. IN=5009.44 (S) INV. OUT=5009.44 (W) FG=5015.22 N: 1449755.31 E: 3113926.79 30.08 LF 6" PVC @ 1.00% TEMP. PLUG INV. OUT=5009.74 (N) FG=5016.02 N: 1449725.25 E: 3113925.66 Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. MINIMUM COVER OF 4.5' SHALL BE MAINTAINED THROUGHOUT THE WATERLINE AND SERVICE LINE INSTALLATION. MAXIMUM ALLOWED COVER SHALL BE 6' UNLESS SPECIFICALLY APPROVED BY THE CITY. 9. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 10. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. 11. SEE SHEET D8 FOR INLET SCHEDULE AND SHEET EC3 FOR SCOURSTOP SCHEDULE. EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING TELEPHONE PEDESTAL EXISTING TREES EXISTING SANITARY SEWER PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY S PROPOSED SEWER SERVICE PROPOSED RESIDENTIAL WATER SERVICE EXISTING GAS METER W CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=30' SS1 PLAN AND PROFILE SANITARY LINE A1 13 ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH SANITARY LINE A1 Line Over Text 2/19/19 15+25 15+00 14+00 13+00 12+00 11+00 10+00 9+50 8" PVC 8" PVC 8" PVC 8" PVC STA. 10+00.0 CONNECT TO EXISTING 8" TEE w/ TB & 8" GV (N) T.O.P.=5010.44 STA. 14+82.7 CONNECT TO EXISTING 6"x6" TAPPING SADDLE & 6"x8" REDUCER & 8" GV (S) T.O.P.=5029.10 STA. 12+72.2 0.5° DEFLECTION T.O.P.=5015.83 STA. 10+09.22 45° BEND w/ TB T.O.P.=5010.19 STA. 10+12.22 45° BEND w/ TB T.O.P.=5010.10 STA. 11+12.18 45° BEND w/ TB T.O.P.=5009.07 STA. 11+42.11 45° BEND w/ TB T.O.P.=5010.05 STA. 11+64.61 8"x6" TEE w/ TB & 6" GV (E) T.O.P.=5011.05 STA. 11+80.64 8"x6" SWIVEL TEE w/ TB & 6" GV (E) T.O.P.=5011.76 STA. 12+16.81 8"x6" TEE w/ TB & 6" GV (W) T.O.P.=5013.37 STA. 13+42.23 8"x6" TEE w/ TB & 6" GV (W) T.O.P.=5019.58 STA. 14+09.05 BEGIN HORZ. DEFL. T.O.P.=5023.16 STA. 14+33.29 END HORZ. DEFL. T.O.P.=5024.50 50.0' DEF. STA. 14+24.82 T.O.P.=5024.00 STA. 14+74.82 T.O.P.=5028.20 (R821') 100.0' DEF. STA. 10+43.20 T.O.P.=5009.25 STA. 11+43.20 T.O.P.=5010.10 (R1391') 12" HDPE STORM STA.=12+72.24 INV.=5017.43 8" PVC STORM STA.=11+22.34 INV.=5012.71 PROPOSED GROUND EXISTING GROUND STA.=10+90.77 INV.= 5010.26 6" PVC SANITARY STA.=13+25.74 INV.= 5020.20 6" PVC SANITARY S S S F F FDC FDC FDC F UD UD UD UD UD C.O. X X X X X X X X X X X X X X X X X T T T T W W DC DC 6" W 6" W 6" W 6" W 6" W 6" W 6" W 6" W CONNECT TO EXISTING 6"x6" TAPPING SADDLE & 6"x8" REDUCER & 8" GV (S) N:1450087.60 E:3113822.51 2" WATER METER N:1450060.18 E:3113787.50 23.56 LF 6" PVC N85°01'37"W 16.14 LF 6" PVC N85°01'37"W 23.00 LF 6" PVC S85°01'37"E 8"x6" TEE w/ TB & 6" GV (E) N:1449770.46 E:3113799.90 8"x6" SWIVEL TEE w/ TB & 6" GV (E) N:1449786.43 E:3113801.29 FH ASSEMBLY N:1449784.44 E:3113824.20 8"x6" TEE w/ TB & 6" GV (W) N:1449822.46 E:3113804.42 8"x6" TEE w/ TB & 6" GV (W) N:1449947.42 E:3113815.30 22.50 LF 8" PVC N04°58'23"E 16.03 LF 8" PVC N04°58'23"E 36.17 LF 8" PVC N04°58'23"E 125.43 LF 8" PVC N04°58'23"E 66.82 LF 8" PVC N04°58'23"E 49.40 LF 8" PVC N00°20'36"E 24.24 LF 8" PVC R=300.00' BEGIN HORZ. DEFL. N:1450013.99 E:3113821.09 END HORZ. DEFL. N:1450038.20 E:3113822.21 PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=30' ( IN FEET ) 0 1 INCH = 30 FEET 30 30 60 90 NORTH WATER LINE A CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. MINIMUM COVER OF 4.5' SHALL BE MAINTAINED THROUGHOUT THE WATERLINE AND SERVICE LINE INSTALLATION. MAXIMUM ALLOWED COVER SHALL BE 6' UNLESS SPECIFICALLY APPROVED BY THE CITY. 9. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 10. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. 11. SEE SHEET D8 FOR INLET SCHEDULE AND SHEET EC3 FOR SCOURSTOP SCHEDULE. EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING TELEPHONE PEDESTAL EXISTING TREES EXISTING SANITARY SEWER PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY S PROPOSED SEWER SERVICE PROPOSED RESIDENTIAL WATER SERVICE EXISTING GAS METER W W1 PLAN AND PROFILE WATER LINE A 11 LINE MATCH STA 11+50 LINE MATCH STA 11+50 NORTH Line Over Text Line Over Text Line Over Text Line Over Text 2/19/19 UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD WALLENBERG DRIVE STUART STREET 54' RIGHT OF WAY LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: DEVORE, JANICE S. LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HANSCH, EDWARD C & DEBRA J LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HUFBAURER, RUTH TRACT B PULSE PUD 1ST OWNER: NORTH SPRING CREEK PROPERTIES LLC TRACT C YOUNG'S CREEK OWNER: CITY OF FORT COLLINS TRACT B YOUNG'S CREEK OWNER: CITY OF FORT COLLINS BUILDING C BUILDING D BUILDING E PEDESTRIAN BRIDGE RAIN GARDEN 3 CITY OF FORT COLLINS 100-YR FLOODWAY CITY OF FORT COLLINS 100-YR FLOODPLAIN CITY OF FORT COLLINS 100-YR FLOODPLAIN 8' CURB CUT 2' REVERSE SIDEWALK CHASE 4' CURB CUT RAIN GARDEN 2 RAIN GARDEN 4 (2) 2' REVERSE SIDEWALK CHASES 5' SIDEWALK HOBBIT STREET 54' RIGHT OF WAY EXISTING WETLANDS NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE N:1449442.67 E:3113711.08 SET 24" #4 REBAR WITH 2" ALUMINUM CAP "KS" NATURAL HABITAT BUFFER ZONE FEMA 100-YR HIGH-RISK FLOOD FRINGE FEMA 100-YR HIGH-RISK FLOOD FRINGE EX. 10' SEWER EASEMENT BOOK 1204, PAGE 344 EX. 90' STORM DRAINAGE EASEMENT REC. NO. 86072551 26' EAE 24' EAE 24' EAE 24' EMERGENCY ACCESS EASEMENT BY SEPARATE DOCUMENT UTILITY AND ACCESS EASEMENT BY SEPARATE DOCUMENT PUBLIC ACCESS TRAIL EASEMENT BY SEPARATE DOCUMENT DRAINAGE EASEMENT BY SEPARATE DOCUMENT OFF-SITE RIGHT OF WAY DEDICATION BY SEPARATE DOCUMENT OFF-SITE RIGHT OF WAY DEDICATION BY SEPARATE DOCUMENT RIGHT OF WAY DEDICATION OFF-SITE 9' UTILITY EASEMENT BY SEPARATE DOCUMENT OFF-SITE 9' UTILITY EASEMENT BY SEPARATE DOCUMENT 9' UTILITY EASEMENT 13.27 12.54 13.18 12.65 12.91 12.91 13.05 12.77 12.74 12.13 12.48 13.07 12.63 13.00 13.18 14.85 13.15 13.93 13.29 12.93 13.75 14.74 14.75 15.65 14.82 15.53 14.86 13.42 14.19 14.20 14.83 15.70 FFE=15.70 FFE=14.50 FFE=14.75 FFE=15.50 15.53 15.17 15.00 16.58 13.29 11.10 12.85 15.44 13.61 13.51 13.00 12.79 13.16 13.22 12.37 12.20 12.62 12.39 12.79 12.18 12.63 12.11 12.64 12.72 12.90 15.12 15.15.22 25 14.87 13.60 13.72 13.72 13.51 13.35 13.82 13.90 15.20 15.25 14.87 14.76 14.68 14.70 14.10 13.85 13.76 14.01 12.99 12.86 13.34 13.45 13.39 14.48 14.45 14.47 14.56 15.45 15.45 15.56 15.50 15.61 16.05 11.24 10.00 13.72 15.27 15.19 15.52 15.70 15.89 15.98 16.30 17.39 17.38 15.70 15.70 15.07 14.94 15.17 15.00 14.92 15.09 14.86 15.25 16.25 16.25 16.25 16.19 16.19 16.75 14.29 14.19 14.22 14.27 15.75 16.13 16.75 16.75 16.75 16.75 16.75 16.75 16.75 16.50 16.50 15.75 15.00 15.00 14.75 14.75 14.08 14.75 13.94 14.75 14.08 15.00 15.21 14.92 15.25 15.25 15.25 14.83 14.83 14.83 14.83 14.83 14.83 15.50 15.50 15.50 14.87 15.24 15.50 15.50 15.50 16.50 16.50 16.50 16.50 16.50 16.50 16.50 15.75 15.75 15.21 15.13 15.25 15.97 15.94 16.07 16.15 16.16 16.03 16.00 15.16 14.44 14.66 14.75 14.78 14.86 15.24 15.46 15.81 16.21 16.08 15.96 15.46 15.07 14.38 14.13 14.43 14.43 14.39 14.06 14.08 14.25 14.25 14.50 13.76 14.25 14.25 13.60 13.87 13.85 14.25 14.25 13.58 13.58 13.58 13.58 13.68 13.61 15.25 13.83 14.25 13.26 15.29 15.08 15.16 15.03 13.30 13.46 15.25 13.36 13.47 13.20 13.02 12.91 12.78 12.76 12.78 12.92 12.78 12.91 12.91 12.78 12.10 12.23 11.40 11.53 11.40 11.53 11.01 11.14 10.95 10.82 9.80 9.60 9.56 9.63 9.70 11.47 12.89 14.06 14.16 14.16 14.06 14.17 14.06 14.29 14.69 14.69 14.29 14.44 14.69 15.45 15.27 15.11 13.85 14.25 13.58 13.58 13.61 12.10 11.99 15.08 13.62 13.45 10.17 11.10 14.08 14.33 14.90 14.44 14.83 15.20 12.99 13.00 13.36 13.79 12.95 11.11 11.11 13.65 15.11 15.98 13.97 14.92 14.68 16.69 11.85 0.5% 2.5% 2.0% 1.0% 1.0% 0.5% 2.0% FFE=14.50 15.03 15.03 13.17 13.13 TOC 14.50 14.50 14.50 14.75 14.75 14.75 14.75 15.25 15.25 15.25 13.58 14.25 14.25 12.50 12.50 12.50 12.50 12.50 13.47 14.15 14.21 14.25 FFE=15.50 15.50 15.50 15.50 15.50 15.50 14.51 15.19 BFE: 5012.3 BFE: 5011.53 BFE: 5012.93 9.95 12.50 12.50 12.50 12.50 12.81 12.81 12.70 12.71 9.01 9.02 11.25 13.50 13.50 13.50 10.27 2' SIDEWALK CHASE 2' CURB CUT 11.25 11.25 11.25 12.00 12.00 12.00 11.25 11.25 12.00 12.00 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 12.67 12.25 2' SIDEWALK CHASE 11.85 1' SIDEWALK CHASE 13.30 13.38 13.42 13.61 14.24 14.39 14.25 13.27 13.63 13.60 13.25 13.58 13.58 13.25 13.25 13.25 13.45 13.16 13.35 13.18 13.28 13.35 13.25 13.00 13.10 13.11 13.00 13.10 13.00 12.59 11.43 11.43 12.25 12.25 12.25 12.25 12.25 12.25 12.25 11.25 11.25 11.26 11.25 11.25 11.25 11.25 11.26 13.50 13.50 13.50 12.50 13.50 13.50 2.0% 12.25 12.25 14.30 13.96 GB BEGIN CURB CUT END CURB CUT SCOURSTOP - SEE DETAIL, SHEET EC3 SCOURSTOP - SEE DETAIL, SHEET EC3 SCOURSTOP - SEE DETAIL, SHEET EC3 13.30 13.24 13.50 13.78 13.02 13.72 TRANSITION TO 6" CURB HEIGHT 11.97 TRANSITION TO 6" CURB HEIGHT Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC LEGEND: PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. FLOOD ZONE DESIGNATION: ACCORDING TO FEMA MAP NUMBER 08069C0979H, DATED MAY 2, 2012, A PORTION OF THE TRACT ABUTTING THIS LAND IS WITHIN A FEMA DESIGNATED SPECIAL FLOOD HAZARD AREA (SFHA), AND IS SUBJECT TO INUNDATION BY THE 1% ANNUAL CHANCE (100-YEAR) FLOOD. 5. PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY 100-YR HIGH-RISK FLOOD FRINGE, AND MUST COMPLY WITH THE FLOODPLAIN REQUIREMENTS OF CHAPTER 10 OF THE CITY OF FORT COLLINS MUNICIPAL CODE. 6. CONSTRUCTION OF NEW RESIDENTIAL STRUCTURES IS NOT ALLOWED IN THE FLOODWAY. RESIDENTIAL STRUCTURES ARE ALLOWED IN THE FLOOD FRINGE, PROVIDED THAT ALL DUCT WORK, HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS, HOT WATER HEATER, ELECTRICAL AND THE LOWEST FLOOR OF THE BUILDING ARE A MINIMUM OF 18-INCHES ABOVE THE BASE FLOOD ELEVATION (BFE). THAT MINIMUM ELEVATION IS KNOWN AS THE REGULATORY FLOOD PROTECTION ELEVATION (RFPE). RFPE=BFE+18". 7. THE FLOOD FRINGE IS AN AE ZONE, MEANING THAT THE BFE'S HAVE BEEN DETERMINED, SO THE BFE FOR EACH STRUCTURE WILL BE 1.5 FEET ABOVE THE BFE, AND THE RFPE WILL BE BFE + 1.5 FEET. 8. BASEMENTS MAY NOT BE CONSTRUCTED BELOW THE RFPE IN THE FLOOD FRINGE. CRAWL SPACES (IF USED RATHER THAN SLAB_ON_GRADE) MUST BE BUILT IN CONFORMANCE WITH SECTION 10_40 OF CITY OF FORT COLLINS MUNICIPAL CODE (THIS WILL INCLUDE VENTING, SUMP PUMPS, ETC.). 9. NONSTRUCTURAL DEVELOPMENT (FENCES, DETENTION PONDS, HARD SURFACE PATHS, FILL, DRIVEWAYS, PARKING AREAS, VEGETATION, ETC.) IS ALLOWED WITHIN THE 100_YEAR FLOODWAY AS LONG AS IT CAN BE PROVEN THAT THE DEVELOPMENT WILL NOT CAUSE A RISE IN THE BASE FLOOD ELEVATION (BFE) OR A CHANGE TO THE FLOODWAY OR FLOOD FRINGE BOUNDARIES. NONSTRUCTURAL DEVELOPMENT IS NOT RESTRICTED WITHIN THE FLOOD FRINGE. 10. ANY AND ALL CONSTRUCTION ACTIVITIES IN THE FLOODWAY OR FLOOD FRINGE MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT. IF THE CONSTRUCTION IS IN THE FLOODWAY A NO-RISE CERTIFICATION MUST BE APPROVED PRIOR TO CONSTRUCTION. 11. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 12. A FLOODPLAIN USE PERMIT WILL BE REQUIRED FOR STORM OUTFALL LOCATIONS, BRIDGE ABUTMENTS, AND PEDESTRIAN TRAIL LOCATED WITHIN THE FLOODPLAIN. THOUGH STORM OUTFALLS AND BRIDGE ABUTMENTS ARE NOT LOCATED WITHIN THE FLOODWAY, ANY DISTURBANCE OF THE FLOODWAY WILL TRIGGER A NO-RISE CERTIFICATION. 13. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. NOTES: PROPOSED STORM INLET EXISTING SPOT ELEVATION PROPOSED FIRE HYDRANT PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY FLOODPLAIN AND FLOODWAY POROUS LANDSCAPE DETENTION MATCHLINE-SEE SHEET G1 G2 G2 GRADING PLAN 10 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Incorrect Plat Title 2/19/19 Spelling Spelling Spelling Text Over Text C. SHEELY FIRST SUBDIVISION OWNER: HUFBAURER, RUTH LOT 2 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: FONTE, STEVEN J & SARAH C LOT 1 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HOGESTAD, PER M & VEDA V LOT 6 SEAMAN SUBDIVISION OWNER: EWAN, JOHN L & YVONNE S BUILDING A BUILDING B NORTHWEST CORNER SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST FOUND 3 1 4" ALUMINUM CAP ON 2 1 2" PIPE, LS 20123 IN MONUMENT BOX NORTH QUARTER CORNER SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST FOUND 2 1 2" ALUMINUM CAP ON 3 4" REBAR, LS 17497, 1999 IN MONUMENT BOX RAIN GARDEN 1 6' CURB CUT EMERGENCY ACCESS ROAD. ALL-WEATHER, SOLID SURFACE DESIGNED TO WITHSTAND 40 TONS. N:1450087.73 E:3113834.34 SET 24" #4 REBAR WITH 2" ALUMINUM CAP "KS" EX. 15' UTILITY EASEMENT REC. NO. 20040037611 20' EAE 24' EAE 26' EAE 22' EAE 15.65 15.81 15.81 15.86 14.82 15.53 14.86 14.83 15.70 16.31 21.65 21.36 21.85 27.04 29.20 28.68 FFE=26.25 FFE=30.25 FFE=20.00 FFE=15.70 15.00 16.58 21.12 20.79 23.08 22.99 27.48 15.20 15.25 14.87 14.76 14.68 15.45 15.45 15.56 15.50 15.61 16.03 16.05 16.84 21.60 21.96 22.10 27.34 22.78 22.76 22.80 21.66 21.29 15.27 15.19 15.52 15.70 15.89 15.98 16.30 17.39 17.38 17.95 17.96 19.14 19.12 19.85 20.00 20.55 20.56 22.50 22.50 22.50 22.00 22.00 22.00 18.00 17.75 19.69 19.69 16.74 16.20 16.20 16.20 15.70 15.70 15.70 15.07 14.94 15.17 15.00 14.92 15.09 14.86 16.19 14.19 15.75 16.13 16.75 16.08 15.96 15.46 25.25 26.34 26.24 26.02 26.18 26.19 25.87 26.12 26.31 26.75 26.99 27.12 27.92 27.79 28.50 28.25 29.03 29.10 29.50 29.77 29.93 29.89 29.77 30.08 30.48 30.48 31.13 31.23 32.25 32.75 32.75 32.75 32.75 32.25 29.58 29.58 29.58 29.58 28.02 28.13 25.58 25.58 25.58 25.58 25.58 24.28 24.53 23.25 23.75 23.75 24.25 24.25 24.75 20.12 31.68 32.17 32.18 32.34 33.88 33.11 32.95 33.33 33.17 34.77 34.61 34.70 34.58 14.08 14.33 14.90 14.44 14.83 16.78 15.98 16.29 21.13 21.63 22.07 22.97 22.63 21.53 16.69 27.48 18.01 17.64 17.45 17.26 15.97 18.12 0.5% 7.4% 6.0% 29.97 33.76 32.57 28.96 29.97 FFE=30.25 FFE=26.25 21.37 8.1% 21.49 21.94 19.70 19.69 15.03 15.03 21.26 18.34 20.18.66 18 20.99 21.49 20.62 18.59 19.63 20.62 LANDSCAPE WALL 26.25 26.25 26.25 26.25 20.00 20.00 20.00 20.00 14.15 14.21 FFE=20.00 15.19 27.40 31.62 31.80 32.09 31.89 31.49 31.07 30.84 30.19 29.70 10.0% 4.7% 9.2% 15.15 2' SIDEWALK CHASE 16.14 17.31 16.00 15.00 16.00 16.00 15.00 16.00 15.00 16.01 15.01 15.00 16.00 16.00 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC LEGEND: PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB AND GUTTER PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 4. FLOOD ZONE DESIGNATION: ACCORDING TO FEMA MAP NUMBER 08069C0979H, DATED MAY 2, 2012, A PORTION OF THE TRACT ABUTTING THIS LAND IS WITHIN A FEMA DESIGNATED SPECIAL FLOOD HAZARD AREA (SFHA), AND IS SUBJECT TO INUNDATION BY THE 1% ANNUAL CHANCE (100-YEAR) FLOOD. 5. PORTIONS OF THIS PROPERTY ARE LOCATED IN THE FEMA-REGULATORY 100-YR HIGH-RISK FLOOD FRINGE, AND MUST COMPLY WITH THE FLOODPLAIN REQUIREMENTS OF CHAPTER 10 OF THE CITY OF FORT COLLINS MUNICIPAL CODE. 6. CONSTRUCTION OF NEW RESIDENTIAL STRUCTURES IS NOT ALLOWED IN THE FLOODWAY. RESIDENTIAL STRUCTURES ARE ALLOWED IN THE FLOOD FRINGE, PROVIDED THAT ALL DUCT WORK, HEATING, VENTILATION AND AIR CONDITIONING SYSTEMS, HOT WATER HEATER, ELECTRICAL AND THE LOWEST FLOOR OF THE BUILDING ARE A MINIMUM OF 18-INCHES ABOVE THE BASE FLOOD ELEVATION (BFE). THAT MINIMUM ELEVATION IS KNOWN AS THE REGULATORY FLOOD PROTECTION ELEVATION (RFPE). RFPE=BFE+18". 7. THE FLOOD FRINGE IS AN AE ZONE, MEANING THAT THE BFE'S HAVE BEEN DETERMINED, SO THE BFE FOR EACH STRUCTURE WILL BE 1.5 FEET ABOVE THE BFE, AND THE RFPE WILL BE BFE + 1.5 FEET. 8. BASEMENTS MAY NOT BE CONSTRUCTED BELOW THE RFPE IN THE FLOOD FRINGE. CRAWL SPACES (IF USED RATHER THAN SLAB_ON_GRADE) MUST BE BUILT IN CONFORMANCE WITH SECTION 10_40 OF CITY OF FORT COLLINS MUNICIPAL CODE (THIS WILL INCLUDE VENTING, SUMP PUMPS, ETC.). 9. NONSTRUCTURAL DEVELOPMENT (FENCES, DETENTION PONDS, HARD SURFACE PATHS, FILL, DRIVEWAYS, PARKING AREAS, VEGETATION, ETC.) IS ALLOWED WITHIN THE 100_YEAR FLOODWAY AS LONG AS IT CAN BE PROVEN THAT THE DEVELOPMENT WILL NOT CAUSE A RISE IN THE BASE FLOOD ELEVATION (BFE) OR A CHANGE TO THE FLOODWAY OR FLOOD FRINGE BOUNDARIES. NONSTRUCTURAL DEVELOPMENT IS NOT RESTRICTED WITHIN THE FLOOD FRINGE. 10. ANY AND ALL CONSTRUCTION ACTIVITIES IN THE FLOODWAY OR FLOOD FRINGE MUST BE PRECEDED BY AN APPROVED FLOODPLAIN USE PERMIT. IF THE CONSTRUCTION IS IN THE FLOODWAY A NO-RISE CERTIFICATION MUST BE APPROVED PRIOR TO CONSTRUCTION. 11. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 12. A FLOODPLAIN USE PERMIT WILL BE REQUIRED FOR STORM OUTFALL LOCATIONS, BRIDGE ABUTMENTS, AND PEDESTRIAN TRAIL LOCATED WITHIN THE FLOODPLAIN. THOUGH STORM OUTFALLS AND BRIDGE ABUTMENTS ARE NOT LOCATED WITHIN THE FLOODWAY, ANY DISTURBANCE OF THE FLOODWAY WILL TRIGGER A NO-RISE CERTIFICATION. 13. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. NOTES: PROPOSED STORM INLET EXISTING SPOT ELEVATION PROPOSED FIRE HYDRANT PROPOSED LOT LINE PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY FLOODPLAIN AND FLOODWAY POROUS LANDSCAPE DETENTION MATCHLINE-SEE SHEET G2 G1 G1 GRADING PLAN 09 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 2/19/19 Spelling Spelling Spelling Text Over Text UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD S S FDC FDC FDC F S F F UD UD UD UD UD UD C.O. C.O. UD UD UD UD WALLENBERG DRIVE STUART STREET 54' RIGHT OF WAY TRACT C YOUNG'S CREEK OWNER: CITY OF FORT COLLINS TRACT B YOUNG'S CREEK OWNER: CITY OF FORT COLLINS EX. 10' SEWER EASEMENT BOOK 1204, PAGE 344 LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: DEVORE, JANICE S. LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HANSCH, EDWARD C & DEBRA J LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HUFBAURER, RUTH TRACT B PULSE PUD 1ST OWNER: NORTH SPRING CREEK PROPERTIES LLC EX. 90' STORM DRAINAGE EASEMENT REC. NO. 86072551 24' EAE BUILDING C BUILDING D BUILDING E RAIN GARDEN 3 RAIN GARDEN 4 CITY OF FORT COLLINS 100-YR FLOODWAY CITY OF FORT COLLINS 100-YR FLOODPLAIN CITY OF FORT COLLINS 100-YR FLOODPLAIN EXISTING BUILDING EXISTING BUILDING 26' EAE 24' EMERGENCY ACCESS EASEMENT BY SEPARATE DOCUMENT UTILITY AND ACCESS EASEMENT BY SEPARATE DOCUMENT PROPOSED TRANSFORMER PROPOSED TRANSFORMER PEDESTRIAN BRIDGE EXISTING WETLANDS NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE <EDIT> N:1449442.67 E:3113711.08 DRAINAGE EASEMENT BY SEPARATE DOCUMENT PROPOSED TRANSFORMER OFF-SITE RIGHT OF WAY DEDICATION BY SEPARATE DOCUMENT OFF-SITE RIGHT OF WAY DEDICATION BY SEPARATE DOCUMENT RIGHT OF WAY DEDICATION OFF-SITE 9' UTILITY EASEMENT BY SEPARATE DOCUMENT OFF-SITE 9' UTILITY EASEMENT BY SEPARATE DOCUMENT 9' UTILITY EASEMENT SSMH A5 SSMH A3 SSMH A4 SSMH A2 SSMH A1 RAIN GARDEN 2 SANITARY LINE A1 SEE SHEET SS1 INLET 1-2 CONCRETE FES 1-1 STORM DRAIN LINE 1-1 SEE SHEET ST1 INLET 2-2A OUTLET 2-1 STORM DRAIN LINE 2-1 SEE SHEET ST1 INLET 4-2 CONCRETE FES 4-1 STORM DRAIN LINE 4-1 SEE SHEET ST2 OUTLET 5-1 STORM DRAIN LINE 5-1 SEE SHEET ST2 CONCRETE FES 6-1 STORM DRAIN LINE 6-1 SEE SHEET ST3 WATERLINE SEE SHEET W1 RELOCATED FIRE HYDRANT STORM DRAIN LINE 2-2 SEE SHEET ST1 Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. MINIMUM COVER OF 4.5' SHALL BE MAINTAINED THROUGHOUT THE WATERLINE AND SERVICE LINE INSTALLATION. MAXIMUM ALLOWED COVER SHALL BE 6' UNLESS SPECIFICALLY APPROVED BY THE CITY. 9. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 10. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. 11. SEE SHEET D8 FOR INLET SCHEDULE AND SHEET EC3 FOR SCOURSTOP SCHEDULE. EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING TELEPHONE PEDESTAL EXISTING TREES EXISTING SANITARY SEWER PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY S PROPOSED SEWER SERVICE PROPOSED RESIDENTIAL WATER SERVICE EXISTING GAS METER W MATCHLINE-SEE SHEET U1 U2 U2 UTILITY PLAN 08 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH Incorrect Plat Title Spelling Spelling Spelling Text Over Text 2/19/19 C.O. C.O. W. PROSPECT ROAD 102' RIGHT OF WAY LOT 1 LANDMARK SUBDIVISION PUD OWNER: LANDMARK HOUSING LLC LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HUFBAURER, RUTH LOT 2 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: FONTE, STEVEN J & SARAH C LOT 1 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HOGESTAD, PER M & VEDA V EX. 15' UTILITY EASEMENT REC. NO. 20040037611 LOT 6 SEAMAN SUBDIVISION OWNER: EWAN, JOHN L & YVONNE S NORTHWEST CORNER SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST FOUND 3 1 4" ALUMINUM CAP ON 2 1 2" PIPE, LS 20123 IN MONUMENT BOX NORTH QUARTER CORNER SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST FOUND 2 1 2" ALUMINUM CAP ON 3 4" REBAR, LS 17497, 1999 IN MONUMENT BOX 26' EAE 24' EAE 20' EAE BUILDING A BUILDING B RAIN GARDEN 1 EXISTING BUILDING 26' EAE PROPOSED TRANSFORMER PROPOSED TRANSFORMER 22' EAE EMERGENCY ACCESS ROAD. ALL-WEATHER, SOLID SURFACE DESIGNED TO WITHSTAND 40 TONS. <EDIT> N:1450087.73 E:3113834.34 PROPOSED TRANSFORMER SSMH A7 SSMH A5 SANITARY LINE A1 SEE SHEET SS1 STORM DRAIN LINE 2-1 SEE SHEET ST1 INLET 3-2 STMH 3-2 INLET 3-4 CONCRETE FES 3-1 STORM DRAIN LINE 3-1 SEE SHEET ST2 STORM DRAIN LINE 6-1 SEE SHEET ST3 WATERLINE SEE SHEET W1 Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS UTILITIES SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. MINIMUM COVER OF 4.5' SHALL BE MAINTAINED THROUGHOUT THE WATERLINE AND SERVICE LINE INSTALLATION. MAXIMUM ALLOWED COVER SHALL BE 6' UNLESS SPECIFICALLY APPROVED BY THE CITY. 9. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 10. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. 11. SEE SHEET D8 FOR INLET SCHEDULE AND SHEET EC3 FOR SCOURSTOP SCHEDULE. EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING TELEPHONE PEDESTAL EXISTING TREES EXISTING SANITARY SEWER PROPOSED STORM INLET EXISTING LIGHT POLE PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED LOTLINE EASEMENT LINE PROPERTY BOUNDARY S PROPOSED SEWER SERVICE PROPOSED RESIDENTIAL WATER SERVICE EXISTING GAS METER W MATCHLINE-SEE SHEET U2 U1 U1 UTILITY PLAN 07 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH Spelling Spelling Spelling 2/19/19 Text Over Text OWNER: HUFBAURER, RUTH TRACT B PULSE PUD 1ST OWNER: NORTH SPRING CREEK PROPERTIES LLC RAIN GARDEN 2 CITY OF FORT COLLINS 100-YR FLOODWAY CITY OF FORT COLLINS 100-YR FLOODPLAIN CITY OF FORT COLLINS 100-YR FLOODPLAIN RAIN GARDEN 4 RAIN GARDEN 3 TRASH ENCLOSURE OFF-SITE RIGHT OF WAY DEDICATION BY SEPARATE DOCUMENT PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED TRANSFORMER EXISTING WETLANDS NATURAL HABITAT BUFFER ZONE NATURAL HABITAT BUFFER ZONE <EDIT> N:1449442.67 E:3113711.08 TRACT C YOUNG'S CREEK OWNER: CITY OF FORT COLLINS TRACT B YOUNG'S CREEK OWNER: CITY OF FORT COLLINS BUILDING C BUILDING D BUILDING E EXISTING BUILDING 4' SIDEWALK 5' SIDEWALK 5' SIDEWALK 6' SIDEWALK 6' SIDEWALK 5' SIDEWALK 6.5' CONCRETE TRAIL 4' SIDEWALK 10' SIDEWALK 5' SIDEWALK 5' SIDEWALK 5' SIDEWALK PEDESTRIAN BRIDGE EX. 10' SEWER EASEMENT BOOK 1204, PAGE 344 EX. 90' STORM DRAINAGE EASEMENT REC. NO. 86072551 26' EAE 24' EAE 24' EAE 24' 24' 24' EAE 24' EMERGENCY ACCESS EASEMENT BY SEPARATE DOCUMENT UTILITY AND ACCESS EASEMENT BY SEPARATE DOCUMENT DRAINAGE EASEMENT BY SEPARATE DOCUMENT PUBLIC ACCESS TRAIL EASEMENT BY SEPARATE DOCUMENT 9' 17' 8' 13' 17' 17' 9' 8' 9' 17' 9' 19' 8' 17' 8' 17' 9' 8' 17' 17' 9' 17' FEMA 100-YR HIGH-RISK FLOOD FRINGE FEMA 100-YR HIGH-RISK FLOOD FRINGE PROPOSED TRANSFORMER 6' SIDEWALK OFF-SITE RIGHT OF WAY DEDICATION BY SEPARATE DOCUMENT RIGHT OF WAY DEDICATION OFF-SITE 9' UTILITY EASEMENT BY SEPARATE DOCUMENT OFF-SITE 9' UTILITY EASEMENT BY SEPARATE DOCUMENT 9' UTILITY EASEMENT P2 1 9' P2 P2 P2 P2 1 1 1 1 1 1 1 1 2 1 2 2 2 2 2 2 2 2 2 2 ADA RAMP ADA RAMP PAVERS - SEE LANDSCAPE PLANS ADA RAMP 2' CURB CUT N:1449525.79 E:3113709.99 2' SIDEWALK CHASE N:1449495.54 E:3113703.13 (2) 2' REVERSE SIDEWALK CHASES N:1449437.69 E:3113733.95 BEGIN CURB CUT N:1449709.17 E:3113713.95 2' REVERSE SIDEWALK CHASE N:1449693.89 E:3113773.15 4' CURB CUT N:1449484.19 E:3113871.11 2' SIDEWALK CHASE N:1449747.25 E:3113720.39 ADA RAMPS 5 5 8' CURB CUT N:1449553.80 E:3114002.04 STAIRS "VAN-ACCESSIBLE ADA" SIGN N:1449724.00 E:3113934.20 "VAN-ACCESSIBLE ADA" SIGN N:1449538.27 E:3113713.21 ADA RAMP "ADA" SIGN N:1449724.62 E:3113917.79 8' 9' 9' 8' 2'x6' CROSSWALKS @ 4' O.C. ADA RAMP ADA RAMP N:1449573.72 E:3113729.14 N:1449516.88 E:3113804.79 N:1449700.20 E:3113973.82 N:1449644.98 E:3113897.73 PAVERS - SEE LANDSCAPE PLANS N:1449715.95 E:3113806.53 N:1449696.09 E:3113898.14 N:1449747.57 E:3113727.83 HOBBIT STREET 54' RIGHT OF WAY 2' CONCRETE CHASE P12 END CURB CUT N:1449692.90 E:3113727.65 5 P1 TIE TO EXISTING CURB & GUTTER N:1449553.50 E:3113651.16 TIE TO EXISTING CURB & GUTTER N:1449612.12 E:3113694.92 TIE TO EXISTING CURB & GUTTER N:1449685.05 E:3113694.95 "FIRE LANE" SIGN N:1449510.74 E:3113779.79 "FIRE LANE" SIGN N:1449735.39 E:3113742.83 "FIRE LANE" SIGN N:1449734.58 E:3113818.22 "FIRE LANE" SIGN N:1449743.60 E:3113865.74 "FIRE LANE" SIGN N:1449776.78 E:3113792.92 N:1449481.98 E:3113596.95 N:1449481.50 E:3113731.24 N:1449608.39 E:3113729.28 2'x2' CONCRETE PAD 2'x2' CONCRETE PAD 2' SIDEWALK CHASE N:1449448.18 E:3113955.58 Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 7. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE X' PAN PX 18" INFALL VERTICAL CURB AND GUTTER 31" DRIVE-OVER CURB AND GUTTER 1 3 18" OUTFALL VERTICAL CURB AND GUTTER 2 24" INFALL VERTICAL CURB AND GUTTER 4 12" RIBBON CURB 5 MATCHLINE-SEE SHEET HC1 HC2 HC2 HORIZONTAL CONTROL PLAN 06 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH Incorrect Plat Title 2/19/19 Spelling Spelling Spelling FOUND 3 1 4" ALUMINUM CAP ON 2 1 2" PIPE, LS 20123 IN MONUMENT BOX NORTH QUARTER CORNER SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST FOUND 2 1 2" ALUMINUM CAP ON 3 4" REBAR, LS 17497, 1999 IN MONUMENT BOX SIDEWALK BUMP OUT WITH 5' WALK RAIN GARDEN 1 TRASH ENCLOSURE TRASH ENCLOSURE EMERGENCY ACCESS ROAD. ALL-WEATHER, SOLID SURFACE DESIGNED TO WITHSTAND 40 TONS. PROPOSED TRANSFORMER PROPOSED TRANSFORMER <EDIT> N:1450087.73 E:3113834.34 BUILDING A BUILDING B EXISTING BUILDING EXISTING BUILDING 4' SIDEWALK 4' SIDEWALK 5' SIDEWALK EX. 15' UTILITY EASEMENT REC. NO. 20040037611 24' EAE 26' EAE 26' EAE 22' EAE 24' 26' 26' 20' EAE 17' 8' 15' 8' 17' 9' 17' 8' 8' 13' 17' 9' 9' PROPOSED TRANSFORMER SIDEWALK WIDTH VARIES SIDEWALK WIDTH VARIES P2 1 1 5 1 2 2 2 2 2 2 1 3 4 ADA RAMP ADA RAMP w/ HANDRAILS LANDSCAPE WALL PAVERS - SEE LANDSCAPE PLANS 30' RAMP LANDING RAMP LANDING 2' SIDEWALK CHASE N:1449747.25 E:3113720.39 6' CURB CUT N:1449790.15 E:3113905.08 WHEEL STOP (TYP.) - SEE DETAILS WHEEL STOP (TYP.) - SEE DETAILS 5 5 5 5 5 5 STAIRS 8' 9' 9' "VAN-ACCESSIBLE ADA" SIGN N:1449916.71 E:3113771.23 "ADA" SIGN N:1449916.70 E:3113785.23 5' STAIRS 9' 9' 2'x6' CROSSWALKS @ 4' O.C. N:1449747.57 E:3113727.83 N:1449869.56 E:3113786.35 N:1450053.78 E:3113749.89 N:1449920.06 E:3113787.86 TIE TO EXISTING CURB & GUTTER N:1450097.51 E:3113832.86 TIE TO EXISTING CURB & GUTTER N:1450097.86 E:3113788.91 "FIRE LANE" SIGN N:1449735.39 E:3113742.83 "FIRE LANE" SIGN N:1449776.78 E:3113792.92 "FIRE LANE" SIGN N:1449851.49 E:3113799.42 "FIRE LANE" SIGN N:1449874.07 E:3113744.86 "FIRE LANE" SIGN N:1449917.20 E:3113803.13 "FIRE LANE" SIGN N:1449991.92 E:3113809.63 "FIRE LANE" SIGN N:1450050.51 E:3113830.75 N:1449785.66 E:3114023.99 N:1449875.57 E:3113729.86 N:1450023.63 E:3113840.00 2'x2' CONCRETE PAD LINE TABLE LINE L1 L3 L4 L5 L7 L8 L9 L11 L12 L14 L15 L16 L17 L18 L19 L20 L21 L22 L23 L24 L25 L26 L34 L36 L37 L38 L40 L41 LENGTH 15.23' 16.00' 32.00' 18.76' 14.00' 81.00' 13.59' 1.75' 15.33' 53.64' 5.59' 14.00' 118.00' 15.00' 4.00' 26.00' 3.00' 14.00' 36.00' 14.00' 87.59' 41.92' 23.95' 15.00' 104.00' 12.00' 12.00' 96.00' BEARING N00°20'35.54"E N89°39'24.46"W N00°20'35.54"E N00°20'35.54"E S89°39'24.46"E N00°20'35.54"E N89°39'24.46"W N00°20'35.54"E N89°39'24.46"W N00°20'35.54"E S89°39'24.46"E S00°20'35.54"W S89°39'24.46"E N00°20'35.54"E S89°39'24.46"E N00°20'35.54"E N89°39'24.46"W N00°20'35.54"E N89°39'24.46"W S00°20'35.54"W N89°39'24.46"W S69°59'22.46"E S04°58'22.54"W S85°01'37.46"E S04°58'22.54"W N85°01'37.46"W S85°01'37.46"E S04°58'22.54"W LINE TABLE LINE L42 L44 L46 L48 L49 L50 L52 L53 L54 L56 L57 L58 L60 L61 L62 L64 L65 L66 L68 L69 L70 L72 L73 L74 L77 L79 L80 L81 LENGTH 13.00' 1.71' 12.61' 14.00' 90.00' 12.50' 12.50' 80.00' 17.90' 10.00' 96.00' 8.50' 12.50' 99.00' 15.01' 5.00' 24.00' 7.06' 15.00' 72.00' 12.50' 12.50' 90.00' 15.00' 12.44' 15.00' 71.00' 14.00' BEARING N85°01'37.46"W S04°58'22.54"W S87°50'25.46"E N02°09'34.54"E S87°50'25.46"E S02°09'34.54"W N02°09'34.54"E S87°50'25.46"E S02°09'34.54"W S89°39'24.46"E S00°20'35.54"W N89°39'24.46"W S89°39'24.46"E S00°20'35.54"W N89°39'24.46"W S00°16'28.43"W N89°39'24.46"W N00°20'35.54"E N89°39'24.46"W N00°20'35.54"E S89°39'24.46"E N89°39'24.46"W N00°20'35.54"E S89°39'24.46"E N87°50'25.46"W S02°09'34.54"W N87°50'25.46"W N02°09'34.54"E LINE TABLE LINE L83 L87 L88 L89 L91 L92 L93 L94 L96 L98 L99 L100 L102 L103 L104 L106 L108 L110 L112 L114 L116 L117 L118 L119 L120 L122 L123 LENGTH 65.79' 15.54' 45.50' 15.00' 6.20' 24.50' 5.98' 47.82' 108.38' 62.26' 22.00' 16.87' 15.00' 41.00' 14.00' 5.61' 124.22' 26.02' 38.41' 34.83' 1.02' 19.32' 21.10' 3.54' 11.94' 8.62' 12.28' BEARING N87°50'25.46"W S00°00'35.37"W N89°59'24.63"W N00°00'35.37"E N89°59'24.63"W N00°00'35.37"E S89°59'24.63"E S89°59'24.63"E N04°58'22.54"E N89°59'24.63"W N00°00'35.37"E S89°59'24.63"E N00°00'35.37"E S89°59'24.63"E S00°00'35.37"W S89°59'24.63"E N04°58'22.54"E N26°55'25.46"W N84°47'30.68"W N81°52'26.74"E N00°20'35.37"E S89°45'29.69"E S89°21'22.84"E S89°28'23.21"E N59°59'24.63"W N89°39'24.46"W N90°00'00.00"W CURVE TABLE CURVE C1 C2 C3 C4 C5 C6 C7 C8 C10 C14 C18 C22 C24 C25 C26 C27 C28 C29 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 DELTA 19°58'11" 257°59'44" 60°24'18" 90°00'00" 90°00'00" 90°00'00" 90°00'00" 31°13'00" 90°00'00" 90°00'00" 90°00'00" 90°00'00" 43°01'06" 27°03'03" 50°32'44" 61°12'34" 31°02'08" 34°45'27" 24°38'43" 58°49'09" 89°40'00" 90°00'00" 180°00'00" 90°00'00" 92°48'48" 90°00'00" 180°00'00" 91°48'59" RADIUS 209.52' 50.00' 50.00' 3.00' 3.00' 3.00' 4.50' 14.00' 3.00' 2.00' 3.00' 3.00' 40.00' 38.25' 36.76' 62.92' 80.86' 130.15' 50.00' 20.00' 25.00' 2.00' 5.00' 2.00' 8.00' 3.00' 4.50' 3.00' LENGTH 73.02' 225.14' 52.71' 4.71' 4.71' 4.71' 7.07' 7.63' 4.71' 3.14' 4.71' 4.71' 30.03' 18.06' 32.43' 67.22' 43.80' 78.96' 21.51' 20.53' 39.12' 3.14' 15.71' 3.14' 12.96' 4.71' 14.14' 4.81' BEARING N78°56'33"E S19°10'20"W N62°01'57"W N44°39'24"W N45°20'36"E N44°39'24"W N44°39'24"W N74°44'07"E S44°39'24"E N45°20'36"E N44°39'24"W S45°20'36"W S68°50'02"W S56°27'51"E S68°12'41"E S62°52'46"E S47°47'34"E S45°55'54"E S16°13'49"E S33°19'02"E N45°10'35"E S40°01'37"E S04°58'23"W S49°58'23"W S41°26'01"E N47°09'35"E S87°50'25"E S43°44'55"E CHORD 72.66' 77.72' 50.30' 4.24' 4.24' 4.24' 6.36' 7.53' 4.24' 2.83' 4.24' 4.24' 29.33' 17.89' 31.39' 64.06' 43.27' 77.75' 21.34' 19.64' 35.25' 2.83' 10.00' 2.83' 11.59' 4.24' 9.00' 4.31' CURVE TABLE CURVE C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C50 C51 C52 C53 C54 C55 C56 C57 C58 C59 C60 C61 C62 C63 C64 DELTA 180°00'00" 90°08'14" 90°00'00" 180°00'00" 90°00'00" 88°11'01" 90°00'00" 90°00'00" 66°25'55" 55°57'35" 81°40'39" 90°00'00" 85°02'13" 94°57'47" 90°00'00" 90°00'00" 85°02'13" 31°53'48" 55°45'22" 166°39'57" 81°31'51" 29°40'00" 32°54'00" 107°46'59" 74°31'29" RADIUS 4.50' 2.00' 2.00' 4.50' 2.00' 10.00' 2.00' 3.00' 25.00' 49.00' 2.00' 1.50' 25.00' 10.00' 2.00' 3.00' 5.00' 25.00' 19.27' 1.00' 9.00' 27.00' 9.79' 15.42' 11.84' LENGTH 14.14' 3.14' 3.14' 14.14' 3.14' 15.39' 3.14' 4.71' 28.99' 47.86' 2.85' 2.36' 37.10' 16.57' 3.14' 4.71' 7.42' 13.92' 18.75' 2.91' 12.81' 13.98' 5.62' 29.00' 15.40' BEARING S00°20'36"W S45°20'36"W N44°39'24"W N00°20'36"E N45°20'36"E N43°44'55"W S47°09'35"W N42°50'25"W S58°56'37"W S53°42'27"W S40°50'55"W N44°59'25"W N47°29'29"E N42°30'31"W N45°00'35"E S44°59'25"E N47°29'29"E N10°58'31"W N54°48'06"W N01°27'32"W N41°06'31"E N74°49'25"W N73°33'00"W S69°00'31"W S52°22'46"W CHORD 9.00' 2.83' 2.83' 9.00' 2.83' 13.92' 2.83' 4.24' 27.39' 45.98' 2.62' 2.12' 33.79' 14.74' 2.83' 4.24' 6.76' 13.74' 18.02' 1.99' 11.75' 13.82' 5.54' 24.91' 14.34' Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER EXISTING STORM SEWER EXISTING EDGE OF ASPHALT PROPOSED STORM MANHOLE PROPOSED CURB & GUTTER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. 7. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. PROPOSED STORM INLET PROPERTY BOUNDARY PROPOSED LOT LINE EASEMENT LINE SAWCUT LINE EXISTING LOT LINE X' PAN PX 18" INFALL VERTICAL CURB AND GUTTER 31" DRIVE-OVER CURB AND GUTTER 1 3 18" OUTFALL VERTICAL CURB AND GUTTER 2 24" INFALL VERTICAL CURB AND GUTTER 4 12" RIBBON CURB 5 MATCHLINE-SEE SHEET HC2 HC1 HC1 HORIZONTAL CONTROL PLAN 05 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH Spelling Spelling 2/19/19 S S S D D UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD UD S TRACT E YOUNG'S CREEK (TO BE VACATED) TRACT C YOUNG'S CREEK OWNER: CITY OF FORT COLLINS TRACT B YOUNG'S CREEK OWNER: CITY OF FORT COLLINS TRACT D YOUNG'S CREEK (TO BE VACATED) LOT 1 YOUNG'S CREEK (TO BE VACATED) LOT 2 YOUNG'S CREEK (TO BE VACATED) LOT 3 YOUNG'S CREEK (TO BE VACATED) LOT 4 YOUNG'S CREEK (TO BE VACATED) TRACT F YOUNG'S CREEK (TO BE VACATED) HOBBIT STREET RIGHT OF WAY 51' RIGHT OF WAY (TO BE VACATED) EX. 10' SEWER EASEMENT EX. 5' MAINTENANCE EASEMENT BOOK 1204, PAGE 344 REC. NO. 20040037611 TO BE VACATED EX. 20' ACCESS & UTILITY EASEMENT REC. NO. 20040037611 TO BE VACATED EX. 9' UTILITY EASEMENT REC. NO. 20040037611 TO BE VACATED EX. 5' MAINTENANCE EASEMENT REC. NO. 20040037611 TO BE VACATED EX. 5' MAINTENANCE EASEMENT REC. NO. 20040037611 TO BE VACATED EX. 90' STORM DRAINAGE EASEMENT REC. NO. 86072551 EX. 20' ACCESS AND UTILITY EASEMENT REC. NO. 20040037611 TO BE VACATED EXISTING SIDEWALK TO REMAIN RELOCATE EXISTING ELECTRICAL BOX AND LIGHTPOLE EX. FIRE HYDRANT TO BE RELOCATED RELOCATE EXISTING IRRIGATION CONTROL SAWCUT SAWCUT CITY OF FORT COLLINS 100-YR FLOODWAY CITY OF FORT COLLINS 100-YR FLOODPLAIN CITY OF FORT COLLINS 100-YR FLOODPLAIN EXISTING FIRE HYDRANT EX. FIRE HYDRANT TO REMAIN EXISTING WETLANDS WALLENBERG DRIVE STUART STREET 54' RIGHT OF WAY LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: DEVORE, JANICE S. LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HANSCH, EDWARD C & DEBRA J LOT 3 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HUFBAURER, RUTH TRACT B PULSE PUD 1ST OWNER: NORTH SPRING CREEK PROPERTIES LLC N:1449442.67 E:3113711.08 SET 24" #4 REBAR WITH 2" ALUMINUM CAP "KS" FEMA 100-YR HIGH-RISK FLOOD FRINGE FEMA 100-YR HIGH-RISK FLOOD FRINGE HOBBIT STREET RIGHT OF WAY 54' RIGHT OF WAY SAWCUT REMOVE EXISTING BARRICADES / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / REMOVE FIRE HYDRANT LINE REMOVE PORTION OF WATERLINE REMOVE PORTION OF SANITARY DEMO ASPHALT AS NECESSARY DEMO ASPHALT AS NECESSARY ADJUST WATER VALVE RIMS TO FINISHED GRADE Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 KEYMAP DC DC CC LEGEND: EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 VAULT ELEC H Y D CONTROL IRR H2O G EXISTING TREES (TO BE REMOVED) FORT COLLINS 100-YR FLOODWAY FORT COLLINS 100-YR FLOODPLAIN FEMA 100-YR HIGH-RISK FLOOD FRINGE REMOVE EXISTING ASPHALT / CONCRETE / GRAVEL MATCHLINE-SEE SHEET EX1 EX2 EX2 AND DEMOLITION PLAN EXISTING CONDITIONS 04 CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 NORTH Spelling Spelling Spelling 2/19/19 Incorrect Plat Title TRACT A YOUNG'S CREEK (TO BE VACATED) EX. 15' UTILITY EASEMENT REC. NO. 20040037611 EX. 20' UTILITY & EMERGENCY ACCESS EASEMENT REC. NO. 20040037611 TO BE VACATED TRACT A YOUNG'S CREEK (TO BE VACATED) NORTHWEST CORNER SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST FOUND 3 1 4" ALUMINUM CAP ON 2 1 2" PIPE, LS 20123 IN MONUMENT BOX NORTH QUARTER CORNER SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST FOUND 2 1 2" ALUMINUM CAP ON 3 4" REBAR, LS 17497, 1999 IN MONUMENT BOX REMOVE EXISTING ELECTRICAL BOX REMOVE EXISTING SANITARY SEWER MARKERS AND REMOVE/ABANDON SEWER AS NECESSARY REMOVE EXISTING FENCE REMOVE EXISTING FENCE SAWCUT W. PROSPECT ROAD 102' RIGHT OF WAY LOT 1 LANDMARK SUBDIVISION PUD OWNER: LANDMARK HOUSING LLC LOT 2 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: FONTE, STEVEN J & SARAH C LOT 1 ARTHER C. SHEELY FIRST SUBDIVISION OWNER: HOGESTAD, PER M & VEDA V LOT 6 SEAMAN SUBDIVISION OWNER: EWAN, JOHN L & YVONNE S N:1450087.73 E:3113834.34 SET 24" #4 REBAR WITH 2" ALUMINUM CAP "KS" CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 ( IN FEET ) 0 1 INCH = 20 FEET 20 20 40 60 KEYMAP DC DC CC LEGEND: EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. THE EXISTING WETLANDS SHALL NOT BE DISTURBED BY ANY CONSTRUCTION OR DEVELOPMENT ACTIVITIES, EXCEPT AS APPROVED BY THE CITY ENVIRONMENTAL PLANNER AND IN ACCORDANCE WITH SECTION 3.4.1 OF THE LAND USE CODE. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 VAULT ELEC H Y D CONTROL IRR H2O G EXISTING TREES (TO BE REMOVED) FORT COLLINS 100-YR FLOODWAY FORT COLLINS 100-YR FLOODPLAIN FEMA 100-YR HIGH-RISK FLOOD FRINGE REMOVE EXISTING ASPHALT / CONCRETE / GRAVEL MATCHLINE-SEE SHEET EX2 EX1 EX1 AND DEMOLITION PLAN EXISTING CONDITIONS 03 NORTH 2/19/19 Spelling Spelling provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the FINAL DRAINAGE AND EROSION CONTROL REPORT FOR LANDMARK APARTMENTS EXPANSION by Northern Engineering Services, Inc. dated JANUARY 25, 2019, shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by the City of Fort collins. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 29-92 Approximate 300 feet south of West Prospect Road and Shields Street, on the north end of the west bridge parapet wall. Elevation= 5025.67 City of Fort Collins Benchmark 28-92 Southwest corner of West Prospect Road and Center Avenue, on a water valve pit. Elevation= 5010.65 Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.17 BASIS OF BEARING The West line of Young's Creek as bearing North 00°00'35" East (assumed bearing). 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Portions of the property are within FEMA Floodplain Zone AE, Fort Collins designated Floodplain and Fort Collins designated floodway. A Floodplain Use Permit is required for any development within the floodplain. See Grading Plan for detailed notes concerning construction within the floodplain and floodway. 49. Approved Variances are listed as follows: a. Parking Setback Variance for proposed parking off Hobbit Street b. Sidewalk around cul-de-sac at Hobbit termination is attached CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner CS2 CONSTRUCTION NOTES GENERAL AND 2/19/19 02 BASIS OF BEARINGS See sheet CS1. respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: PROJECT LOCATION VICINITY MAP NORTH DEVELOPER/APPLICANT SITE ENGINEER SURVEYOR ORIGINAL FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: PROJECT BENCHMARKS: SHEET INDEX LANDMARK APARTMENTS EXPANSION LOTS 1 & 2, LANDMARK APARTMENTS, LOCATED IN THE NORTHWEST QUARTER OF SECTION 23, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Sheet LANDMARK APARTMENTS EXPANSION These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 E NGINEER ING N O R T H E RN PHONE: 970.221.4158 www.northernengineering.com of 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner GAS----------------- Xcel Energy----------------------------- Al Ermer (970) 225-7869 ELECTRIC-------- City of Fort Collins Light & Power-- Luke Unruh (970) 416-2724 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0245 TELECOM.--------Qwest Local Network------------------ Bill Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 WASTEWATER--City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 STORMWATER- City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 King Surveyors King Surveyors Project No. 2012606 Date: February 15, 2016 Soilogic, Inc. "GEOTECHNICAL SUBSURFACE EXPLORATION REPORT LANDMARK APARTMENTS EXPANSION" Soilogic Project No. 16-1024 Date: February 24, 2016 PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 29-92 Approximate 300 feet south of West Prospect Road and Shields Street, on the north end of the west bridge parapet wall. Elevation= 5025.67 City of Fort Collins Benchmark 28-92 Southwest corner of West Prospect Road and Center Avenue, on a water valve pit. Elevation= 5010.65 Please note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.17 BASIS OF BEARING The West line of Young's Creek as bearing North 00°00'35" East (assumed bearing). 01 CS1 COVER SHEET 02 CS2 GENERAL AND CONSTRUCTION NOTES 03-04 EX1-EX2 EXISTING CONDITIONS AND DEMOLITION PLAN 05-06 HC1-HC2 HORIZONTAL CONTROL PLAN 07-08 U1-U2 UTILITY PLAN 09-10 G1-G2 GRADING PLAN 11 W1 WATER LINE A PLAN AND PROFILE 12 W2 WATER LINES B & C PLAN AND PROFILE 13 SS1 SANITARY LINE A1 PLAN AND PROFILE 14 ST1 STORM DRAIN LINES 1-1, 2-1, & 2-2 PLAN AND PROFILE 15 ST2 STORM DRAIN LINES 3-1, 4-1, & 5-1 PLAN AND PROFILE 16 ST3 STORM DRAIN LINE 6-1 PLAN AND PROFILE 17-18 EC1-EC2 EROSION CONTROL PLAN 19 EC3 EROSION CONTROL DETAILS 20 D1 SANITARY DETAILS 21-22 D2-D3 WATER DETAILS 23-24 D4-D5 SITE DETAILS 25-27 D6-D8 DRAINAGE DETAILS 28-29 D8-D9 PEDESTRIAN BRIDGE DETAILS 30 DR1 DRAINAGE PLAN CS1 COVER SHEET 01 ABC = AGGREGATE BASE COURSE ACP = ASBESTOS-CEMENT PIPE BLDG = BUILDING BP = BEGINNING POINT CL = CENTERLINE CMP = CORRUGATED METAL PIPE C.O. = CLEAN OUT DIP = DUCTILE IRON PIPE EAE = EMERGENCY ACCESS EASEMENT EL or ELEV = ELEVATION EOA = EDGE OF ASPHALT EP = ENDING POINT FES = FLARED END SECTION FFE = FINISHED FLOOR ELEVATION FL = FLOWLINE FH = FIRE HYDRANT GB = GRADE BREAK GV = GATE VALVE HC = HANDICAP HP = HIGH POINT INV = INVERT LF = LINEAR FEET LP = LOW POINT MAX = MAXIMUM MH or M.H. = MANHOLE MIN = MINIMUM PC = POINT OF CURVATURE PCR = POINT OF CURVE RETURN PERF = PERFORATED PRC = POINT OF REVERSE CURVE PT = POINT OF TANGENCY PVC = POLYVINYL CHLORIDE PVI = POINT OF VERTICAL INTERSECTION PVMT = PAVEMENT RCP = REINFORCED CONCRETE PIPE RD = ROOF DRAIN RDC = ROOF DRAIN CONNECTION ROW = RIGHT OF WAY STA = STATION STD = STANDARD SQ FT = SQUARE FOOT / FEET SW = STEEL WATERLINE TB = THRUST BLOCK TBC = TOP BACK OF CURB TH = THORNBURG-HAMILTON TYP = TYPICAL WSEL = WATER SURFACE ELEVATION ABBREVIATIONS: BASIS OF BEARINGS The City's Benchmark Statement format has been revised. This does not match the revised format. See written comments. 2/19/19 These do not match these sheets.