HomeMy WebLinkAboutFTC EAST DALE WTE VERIZON - BDR180016 - SUBMITTAL DOCUMENTS - ROUND 4 - RESPONSE TO STAFF REVIEW COMMENTS16035 Table Mountain Pkwy
Golden, CO 80403
P: 303-993-3293 / F: 303-993-3019
Re:
FTC EAST DALE
Dated: 03/07/2019
Project: Cell site Rooftop Cupola
Job Address: 901 Riverside Ave., Ft. Collins, CO. 80524
To: Brandy Bethurem Harras
Development Review Coordinator
City of Fort Collins Community Development & Neighborhood Services
281 N. College Ave. Fort Collins, CO 80524
Hello Brandy,
We are sending you this narrative pertaining to the Drawing Revisions you requested below:
As Noted:
RE: FTC EAST DALE, BDR180016, Round Number 3
Please see the following summary of comments from City staff and outside reviewing agencies for your
submittal of the above referenced project. If you have any questions regarding these comments or the next
steps in the review process, you may contact the individual commenter or direct your questions through
your Development Review Coordinator, Brandy Bethurem Harras, at 970.416.2744 or
bbethuremharras@fcgov.com.
Comment Summary:
Department: Planning Services
Contact: Kai Kleer, 970-416-4284, kkleer@fcgov.com
Topic: General
Comment Number: 9
01/29/2019 FOR APPROVAL:
Update project data with the following information:
Parcel Number: 9713131002
Zoning Designation: Limited Commercial (C-L)
Governing Codes if Applicable: Update list of applicable code to show 2018 International Codes
that were adopted on 1/14/2019.
[RESPONSE] The Project Information has been updated on the T1 Sheet
Comment Number: 10
01/29/2019 FOR APPROVAL:
Change color of new louvered screen wall to gray.
[RESPONSE] The callouts for the Louver Screen have been updated to specify the
COLOR TO BE GRAY
16035 Table Mountain Pkwy
Golden, CO 80403
P: 303-993-3293 / F: 303-993-3019
Department: Forestry
Contact: Nils Saha, nsaha@fcgov.com
Topic: General
Comment Number: 3
01/28/2019: FOR APPROVAL - UNRESOLVED
While the response letter indicates that there are no construction activities planned near existing
trees, the plans show underground fiber run inside the utility easement, which appears to be
approximately 12’ from one of the crabapples and adjacent to the serviceberry. Please clarify
whether any excavation is proposed in this easement. If so, please note “existing trees to remain”
on the site plan. Additionally, please add tree protection notes to the site plan. This is available
from City Forestry or the project planner.
[RESPONSE] Tree identification table added to SITE PLAN and Tree Protection Notes
added to Notes Page FCN1
Topic: Landscape Plans
Comment Number: 2
01/28/2019: FOR APPROVAL-UPDATED
Please include the following tree inventory information in table format with the next round of
submittals:
Tree #1: Crabapple – 9” in diameter in good condition (1.5 mitigation tree, if damaged or removed)
Tree #2: Crabapple – 9” in diameter in good condition (1.5 mitigation tree, if damaged or removed)
Tree #3: Serviceberry – 3” in diameter in good condition (1 for 1 replacement no upsized, if
damaged or removed)
Please label trees according to the inventory (see redlines).
[RESPONSE] Tree Identification Table (TABLE Z1-A) added to SITE PLAN
Department: Light And Power
Contact: Luke Unruh, 9704162724, lunruh@fcgov.com
Topic: General
Comment Number: 1
10/29/2018: INFORMATION ONLY:
The transformer that feeds 901 Riverside sits on the neighboring property. The new service from
the existing transformer will be the owners responsibility. I recommend that the new electric service
be placed in an easement.
Comment Number: 2
10/29/2018: INFORMATION ONLY:
Electric capacity fees, development fees, building site charges and any system modification
charges necessary to feed the site will apply to this development. Please contact me or visit the
following website for an estimate of development charges and fees:
Comment Number: 3
10/29/2018: INFORMATION ONLY:
The existing transformer may need to be upgraded depending on power requirements. Please provide a
commercial service information form (C-1 form) and a one-line diagram will need to be completed and
submitted to Light & Power Engineering for review. A link to the C-1 form is below:
http://www.fcgov.com/utilities/business/builders-and-developers/development-forms-guidelines-regulations
16035 Table Mountain Pkwy
Golden, CO 80403
P: 303-993-3293 / F: 303-993-3019
Comment Number: 4
10/30/2018: FOR APPROVAL:
Please contact me to further discuss this project at 970-416-2724
Department: Stormwater Engineering
Contact: Dan Mogen, 970-305-5989, dmogen@fcgov.com
Topic: General
Comment Number: 5
01/25/2019: FOR APPROVAL:
While the plans have changed, it still appears there will be work done adjacent to the drainage
area. Please add a note to the plans (both site plan Z1 and utility coordination plan UC1) that
indicates to the contractor that they are to stay out of the drainage area, meaning no driving across
or compacting the drainage/water quality swale area (where your plans show riprap).
[RESPONSE] Drainage Swale protection note added to sheets Z1 and UC1
Department: Water-Wastewater Engineering
Contact: Dan Mogen, 970-305-5989, dmogen@fcgov.com
Topic: General
Comment Number: 2
01/25/2019: FOR APPROVAL:
While the design for this project has changed, the water service per the original utility plans still
appears to be cross the area of the NEW VZW U/G FIBER RUN.
It's been requested previously that the water service and meter be shown on these plans, and I
understand that a waterline is shown on the plans. This waterline differs in location from the
original utility plans for this site/building. Has it been verified that this line as shown is indeed the
water service? Or is it possible this is an irrigation line?
It does not appear the water meter location is currently shown; please add to the plans (Z1 and
UC1). Please call out the waterline ("UW") as private with notes to provide separation as indicated
below.
From prior comments: this water meter and service needs to be located and the proposed design
needs to show that the equipment and conduits are a minimum of 6’ away from the existing water
service and if crossing the existing water service perpendicularly, then the conduits must be shown
to cross over or above the water service with a minimum of 18” clearance.
[RESPONSE] Water Line Shown as indicated on original Utility Plans, Water Meter
added. New Fiber Entrance shifted to the East to provide MIN. 6’ Separation.
Comment Number: 3
01/25/2019: FOR APPROVAL:
My phone number has been changed. Please update to 970-305-5989 on the Utility Coordination
Plan (Sheet UC1).
16035 Table Mountain Pkwy
Golden, CO 80403
P: 303-993-3293 / F: 303-993-3019
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
Topic: General
Comment Number: 2
01/24/2019: FOR APPROVAL:
Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See
redlines.
[RESPONSE] Sheet Index and Sheet Titles updated
10/29/2018: FOR APPROVAL:
Some of the sheet titles in the sheet index do not match the sheet titles on the noted sheets. See
redlines.
07/10/2018: Some of the sheet titles in the sheet index do not match the sheet titles on the noted
sheets. See redlines.
Comment Number: 4
01/24/2019: FOR APPROVAL:
There is text that needs to be masked. Mask all text in hatched areas. See redlines.
[RESPONSE] Text Masking Updated
10/29/2018: FOR APPROVAL:
There is text that needs to be masked. Mask all text in hatched areas. See redlines.
Comment Number: 5
01/24/2019: FOR APPROVAL:
There are line over text issues. See redlines.
[RESPONSE] Text Masking Updated
Department: PFA
Contact: Andrew Rosen, 970-416-2599, arosen@poudre-fire.org
Topic: General
Comment Number: 5
01/23/2019: INFORMATION ONLY:
All PFA comments have been resolved. No further action required
Brad Bryant
A & E PROJECT MANAGER
CENTERLINE SOLUTIONS
16035 Table Mountain Parkway
Golden, CO 80403
Phone: 303.993.3293 x1383
Mobile: 720.284.8628