Loading...
HomeMy WebLinkAboutAFFORDABLE SELF STORAGE - FDP180020 - SUBMITTAL DOCUMENTS - ROUND 2 - SITE PLANSITE PLAN NOTES PROJECT DATA NAME OF PROJECT: ADDRESS: ZIP CODE PROPOSED USE LEGAL DESCRIPTION AFFORDABLE SELF STORAGE CORNER OF CONIFER AND RED CEDAR CIRCLE 80524 SELF STORAGE LOT 1, AFFORDABLE STORAGE OF FORT COLLINS APPLICABLE ZONING CODE ZONE DISTRICT: GROSS BUILDING AREA: TOTAL LOT SIZE: TOTAL BUILDING COVERAGE FOOTPRINT: FLOOR AREA RATIO: PARKING & DRIVE AREA: LANDSCAPE AREA: STORMWATER DETENTION AREA: SIDEWALK AREA: GROSS/NET DENSITY: (I) INDUSTRIAL DISTRICT S1 STORAGE 95,748 SQUARE FEET B BUSINESS (OFFICE) 1,025 SQUARE FEET TOTAL BUILDING AREA 96,773 SQUARE FEET 140,903 SQUARE FEET (3.23 ACRES) ZONING RESTRICTIONS ALLOWED PROPOSED NUMBER OF STORIES - 2 APPLICABLE CODE 2012 IBC BUILDING CODE 2012 IECC ENERGY CONSERVATION 2012 IFGC FUEL GAS 2012 IPC PLUMBING 2012 IMC MECHANICAL 2012 IFC FIRE CODE 2014 NEC ELECTRICAL BUILDING DATA CONSTRUCTION TYPE II-B OCCUPANCY S-1 SPRINKLERS YES NFPA-13 (2-STORY ONLY) STANDPIPES -- FIRE DISTRICT POUDRE FIRE AUTHORITY FLOOD HAZARD AREA NO BUILDING HEIGHT 27'-0" PARKING TOTAL NUMBER OF SPACES NUMBER OF LOADING SPACES NUMBER OF ACCESSIBLE SPACES PROVIDED: 6 PROVIDED: 2 PROVIDED: 2 REQUIRED: 1 REQUIREMENTS .5 PER EACH EMPLOYEE MINIMUM AND .75 PER EMPLOYEE MAXIMUM 2 EMPLOYEES X .75 = 1.5 SPACES = 2 REQUIRED APPLICABLE NOTES FROM THE DEVELOPMENT FINAL PLAN 1. ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF ALL BUILDINGS WILL BE LOCATED WITHIN 150' OF ACCESS ROADWAY IN WHICH EMERGENCY FIRE EQUIPMENT CAN BE MANEUVERED OR THE BUILDINGS WILL BE PROVIDED WITH AN APPROVED FIRE EXTINGUISHING SYSTEM. 2. REFER TO UTILITIES PLAN FOR LOCATION OF UTILITIES AND DRAINAGE. 3. SIDEWALKS AND RAMPS WILL CONFORM TO CITY STANDARDS. 4. PROPOSED EXTERIOR LIGHTING WILL BE POLE-MOUNTED LUMINARIES AT DRIVES AND PARKING AREAS. BOTH POLE AND BUILDING MOUNTED FIXTURES WILL FEATURE DOWN-DIRECTIONAL AND SHARP CUTOFF LUMINARIES. ALL WALL DN 10' 13' 168' 10' 85' 14' 10' 65' 62' 12' 40' 17' 43' 27' 52' 17' 52' 40' 11' 32' 21' 16' 21' 16' BUILDING D 7,680 TOTAL SQ' BLDG HEIGHT: 16'-0" BUILDING C 6,600 TOTAL SQ' BLDG HEIGHT: 11'-6" BUILDING B 4,400 TOTAL SQ' BLDG HEIGHT: 12'-0" BUILDING A 28,809 SQ' EA. FLOOR TOTAL= 57,618 SQ' BLDG HEIGHT: 27'-0" 5' DETACHED SW NEW 5' DETACHED SW 20' WIDE WROUGHT IRON LIFT SECURITY GATE W/INTEGRATED KNOX KEYSWITCH BIKE RACK (4) RED CEDAR CIRCLE CONIFER STREET EX. STREET TREES (5 TOTAL) 24' WIDE EMER. FIRE ACCESS GATE W/ KNOX BOX 10' WIDE LANDSCAPE BUFFER YARD R=15.00' H.C. SIGN R=5.00' 24' WIDE WROUGHT IRON LIFT SECURITY GATE W/INTEGRATED KNOX KEYSWITCH SITE DATA 140,903 S.F. 2-3/8" OD SCHEDULE 40 STEEL PIPE COLOR: CHARCOAL GRAY FINISH GRADE 4 TOTAL SPACES 5' - 0 1/2" 3' - 0" 1' - 5 1/2" EXPANSION JOINT & SEALANT CONCRETE PIER 6" DIAMETER STEEL BOLLARD FILLED WITH CONCRETE PAINTED "HIGH- VISIBILITY YELLOW" SLOPE T.O. CONCRETE 9" 2' - 6" 5' - 0" 6" 6" 6" 1' - 6" STALL SURFACE CENTER SIGN WITHIN PARKING STALL AT INTERIOR END R7-8 2" DIAMETER METAL PIPE WHERE WALL- MOUNTING IS NOT PRACTICAL R7-201 R78b AT VAN STALLS ABOVE STALL SURFACE 7' - 0" 6" 1" 1' - 6" 1' - 0" 3" WIDE PAINTED STRIPES AT 3'-0" O.C. INTERNATIONAL ACCESSIBLE SYMBOL PER ICC/ANSI 117.1-2003 SECTION 703.6.3.1 STANDARDAISLE PARKING STALL ACCESSIBLE STALL WITH ACCESS 4" WIDE PAINTED STRIPE (TYP.) 1. Paved with asphalt, concrete or pavers 2. Designed so that slope, measured in any direction, and does not exceed a one (I) foot rise to a fifty (50) foot run; 3. Designed so that whenever there is more than a one-half (1/2) inch change in the elevation of the surface between a handicapped accessible route and the handicapped parking space, a ramp shall be provided to connect the route and the parking space. 8'-0" MIN AT VAN 9' - 0" 18' - 0" 9' - 0" 9' - 0" 18' - 0" 18' - 0" SURFACE NO PARKING - FIRE LANE BIDIRECTIONAL SIGN COMPLYING WITH D103.6 2" DIAMETER METAL PIPE WHERE WALL-MOUNTING IS NOT PRACTICAL 7' - 7" 1' - 6" 1' - 0" CONTRACTOR TO CORDINATE DIRECTIONAL ARROW WITH FIRE DEPARTMENT 6' - 0" 6' - 0" FINISHED GRADE POST TYPICAL SQUARE PICKET CHANNEL RAIL 22' CLEAR 24'-0" DOUBLE LEAF ORNAMENTAL SWING GATE 6' - 0" POST TOP RAIL BRACKET SQUARE POST SQUARE PICKET U-CHANNEL RAIL INDUSTRIAL DRIVE RIVET 6' - 0" FENCE LINE LATCH POST FINISHED GRADE ORNAMENTAL VERTICAL PIVOT GATE 6'-0" ORNAMENTAL FENCE DETAIL ORNAMENTAL FENCE DETAILS ARE TYPICAL AND WILL VARY BASED ON FENCE MANUFACTURER ORNAMENTAL VERTICAL PIVOT GATE PLAN BARRIER SCREEN CONCRETE OPERATOR PAD OPERATOR PROPERTY LINE 30' LANDSCAPE BUFFER LEVEL 1 100' - 0" 7' - 0" 6' - 0" METAL PANEL STK2000 STRUKTUROC TEXTURED STUCCO FINISH COLOR: LIGHT STONE CMU SPLITFACE BLOCK BASALITE 5608 CHARCOAL PRECAST SILL 22 GA. PRE-FINISHED METAL PARAPET CAP 3780 East 15th Street, Suite 201 Loveland, Colorado 80538 970.669.8220 E-mail: info@hauserarchitectspc.com HauserArchitectspc.com SHEET Hauser Architects, P.C. 3/15/2019 10:25:06 AM CONIFER AND RED CEDAR CIRCLE AFFORDABLE STORAGE OF FORT COLLINS ARCHITECTURAL SITE DETAILS A3 1/2" = 1'-0" 1 BIKE RACK DETAIL - PDP 1/2" = 1'-0" 7 PIPE BOLLARD TYP. - PDP 1/2" = 1'-0" 5 ACCESSIBLE PARKING SIGNAGE - PDP 1/8" = 1'-0" 4 PARKING STALL STRIPING - PDP 1/2" = 1'-0" 6 NO PARKING - FIRE LANE SIGNAGE - PDP 1/4" = 1'-0" 3 FENCE SPEC - PDP 3/16" = 1'-0" 2 FENCE / GATE DETAIL - PDP 1/4" = 1'-0" 8 SCREEN FENCE PLAN - PDP 1/4" = 1'-0" 9 SCREEN FENCE ELEVATION - PDP REVISIONS PDP Submittal 01.31.2017 PDP Submittal #5 08.10.2018 FDP Submittal #2 03.15.2019 1 PDP Submittal #2 03.28.2017 2 PDP Submittal #3 12.13.2017 3 PDP Submittal #4 02.16.2018 3.23 ACRES LOADING ZONE 3HR FIRE BARRIER ENTRY / EXIT STORAGE EXIT STORAGE OVERHEAD ENTRY CANOPY 6 PARKING SPACES EXISTING HYD. 5'-0" BIKE LANE STRIPED AREA-VAN ACCESSIBLE RAMP EXISTING CONCRETE TO REMAIN EXISTING SIDE WALK TO REMAIN EXISTING SIDE WALK TO REMAIN BUILDING F 18,275 TOTAL SQ' BLDG HEIGHT: 14'-11" 3HR FIRE BARRIER EXISTING TREES, 4" CAL. @ 48" A.F.G. EX. STREET TREES (5 TOTAL) UTILITY EASEMENT EXISTING SIDE WALK TO REMAIN MAN GATE W/ PANIC HARDWARE BOLLARD, TYP. BOLLARD, TYP. BOLLARD, TYP. BOLLARD, TYP. BOLLARD, TYP. GATE CONTROLLER BOLLARD, TYP. BOLLARD, TYP. WATER SEWER SIGHT TRIANGLE SIGHT TRIANGLE FUTURE JEROME ROW 60' - 0" 3HR FIREWALL (8" CMU) FIRE AREA 1 3,300 SF FIRE AREA 2 3,300 SF FIRE AREA 2 4,550 SF FIRE AREA 3 5,000 SF NO PARKING - FIRE LANE RE: SITE DETAILS TYPICAL NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. FIRE ACCESS GATE DO NOT ENTER "EXIT ONLY" SIGNAGE DO NOT ENTER "EXIT ONLY" SIGNAGE NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. PROPOSED TYPE II BUS STOP TRANSFORT BUS STOP SIGN 5' WIDE X 8' DEEP ADA PAD 3'x6' HITCHING POST BIKE RACK 6' BENCH POWDER COATED REFER TO TRANSFORT BUS STOP DESIGN STANDARDS AND GUIDELINES FOR TYPE II BUS STOPS NEW ROADWAY LIGHT NEW ROADWAY LIGHT x x x x 6' METAL FENCE - POWDER COAT BLACK 6' METAL FENCE - POWDER COAT BLACK 6' METAL FENCE - POWDER COAT BLACK 6' METAL FENCE - POWDER COAT BLACK x 6' METAL FENCE - POWDER COAT BLACK FDC TRUNCATED DOMES SIGHT TRIANGLE SITE TRIANGLE FIRE AREA 2 4,800 SF FIRE AREA 1 2,880 SF 3HR FIRE BARRIER NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. KNOX BOX 9' WIDE UTILITY EASEMENT NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. BUILDING E 2,200 TOTAL SQ' BLDG HEIGHT: 16'-0" NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. 30.00 ft 219.50 ft 20.00 ft 10.14 ft 5.00 ft 129.00 ft LANDSCAPE YARD 30.00 ft 29.50 ft 30.00 ft 29.50 ft 10.56 ft 276.44 ft 20.00 ft 110.00 ft 10.05 ft 220.00 ft 20.00 ft 18.00 ft 9.00 ft 15.00 ft 2.00 ft 5.00 ft 7.45 ft 8.10 ft 5.00 ft 3HR FIRE BARRIER 85.00 ft PROPERTY LINE FIRE AREA 1 975 SF FIRE AREA 4 3,500 SF FIRE AREA 5 4,250 SF 3HR FIRE BARRIER 3HR FIRE BARRIER 3HR FIRE BARRIER NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. 24.00 ft PROPOSED SCREEN FENCE, RE: SHEET A3 FOR ELEVATION AND PLAN A3 8 ENTRY / EXIT STORAGE ENTRY / EXIT STORAGE 24.00 ft 7.05 ft NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. NO PARKING FIRE LANE SIGN, RE: SITE DETAILS, TYPICAL 100' O.C. B40 TURNING TEMPLATE DRAINAGE EASEMENT OFFICE ENTRY / EXIT ANY TREE WITHIN THE SIGHT TRIANGLES NEEDS TO BE PRUNED A MINIMUM OF 8'-0". LOT 4, A MINOR SUBDIVISION PLAT OF CONIFER INDUSTRIAL PARK LOT 1, UNITED WAY HOUSING SERVICES DAY CENTER BOLLARD, TYP. Fire Hydrant FDC EAE/DE 20.00 ft 9' UTILITY EASEMENT EAE UE/EAE DRAINAGE EASEMENT DRAINAGE EASEMENT UTILITY EASEMENT EASTERLY TERMINUS OF UTILITY EASEMENT WESTERLY TERMINUS OF UTILITY EASEMENT 9' UTILITY EASEMENT 13' DRAINAGE EASEMENT DRAINAGE EASEMENT DRAINAGE EASEMENT DRAINAGE EASEMENT 104 ft X X X X X X X X X SOLID COMPOSITE FENCE X X X 3780 East 15th Street, Suite 201 Loveland, Colorado 80538 970.669.8220 E-mail: info@hauserarchitectspc.com HauserArchitectspc.com SHEET Hauser Architects, P.C. 3/15/2019 10:25:04 AM CONIFER AND RED CEDAR CIRCLE AFFORDABLE STORAGE OF FORT COLLINS ARCHITECTURAL SITE PLAN A2 1" = 20'-0" 1 ARCHITECTURAL SITE PLAN - PDP REVISIONS PDP Submittal 01.31.2017 PDP Submittal #5 08.10.2018 FDP Submittal #2 03.15.2019 1 PDP Submittal #2 03.28.2017 2 PDP Submittal #3 12.13.2017 3 PDP Submittal #4 02.16.2018 MOUNTED LIGHT FIXTURES SHALL BE FULLY SHIELDED TO CONCEAL LIGHT SOURCE. 5. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT IS TO BE FULLY SCREENED FROM PUBLIC VIEW WITH ROOFTOP PARAPET WALLS AND LANDSCAPING. CONDUITS, METERS, VENTS AND OTHER EQUIPMENT ATTACHED TO THE BUILDING OR PROTRUDING FROM THE ROOF SHALL BE PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 6. ALL SIGNAGE TO COMPLY WITH LOCAL SIGN CODE. SIGNS ARE NOT APPROVED WITH THIS PLAN. ALL SIGNS WILL BE APPROVED THROUGH A SEPARATE SIGN PERMIT. 7. THE TRASH ENCLOSURES WILL BE MOUNTED ON CONCRETE AND BE CONSTRUCTED OF MATERIALS TO MATCH THE BUILDINGS. ANY GATES CONSTRUCTED WILL BE OF SOLID MATERIAL. 8. BIKE RACKS ARE TO BE PERMANENTLY ANCHORED TO CONCRETE AND WILL NOT INTERFERE WITH PEDESTRIAN WALKWAYS. 9. ALL HANDICAP PARKING SPACES AND RAMPS ARE TO BE VERIFIED WITH CIVIL ENGINEER FOR GRADING, DRAINAGE, AND ACCESSIBLE ROUTE CONSIDERATIONS. HANDICAP PARKING SPACES SHOULD SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES SHOULD SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND NO MORE THAN 1:48 CROSS SLOPE. 10. ALL INTERNAL PEDESTRIAN WALKWAYS SHALL BE DISTINGUISHED FROM DRIVING SURFACES THROUGH THE USE OF DURABLE LOW-MAINTENANCE SURFACE MATERIALS SUCH AS SCORED CONCRETE TO ENHANCE PEDESTRIAN SAFETY AND COMFORT AS WELL AS THE ATTRACTIVENESS OF THE WALKWAYS. 11. ELECTRICAL TRANSFORMERS AND NATURAL GAS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW BY A SOLID HEDGE OF PLANT MATERIAL OR AN ENCLOSURE MEETING THE CLEARANCE SPECIFICATIONS OF LIGHT AND POWER. SUCH ENCLOSURE MUST MATCH THE PREDOMINATE MATERIALS OF THE BUILDING BEING SERVED. TRANSFORMERS MUST BE WITHIN TEN FEET OF HARD SURFACE. 12. IN ORDER TO COMPLY WITH OPERATIONAL AND PHYSICAL COMPATIBILITY STANDARDS, THE OUTDOOR STORAGE OF PRODUCTS OR MATERIALS, INCLUDING TIRE DISPLAY RACKS OR USED TIRES SHALL BE SCREENED FROM PUBLIC VIEW. IN ADDITION, VENDING MACHINES SHALL BE PLACED INSIDE BUILDINGS OR BEHIND SCREEN WALLS. 13. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 14. ANY TREE WITHIN THE SIGHT TRIANGLES NEEDS TO BE PRUNED A MINIMUM OF 8'-0". 15. NO TRASH OR RECYCLING DUMPSTER WILL BE ON SITE. TRASH AND RECYCLING WILL STORED INDOORS FOR THE USE OF THE OFFICE ONLY. THE TRASH AND RECYCLING WILL BE ROLLED OUT TO THE CURB DURING THE SCHEDULED DELIVERY TIMES FOR CURBSIDE COLLECTION USING A 96 GALLON CART. .68 F.A.R. 54,201 SQUARE FEET (1.2 ACRES) - 38% OF LOT 67,964 SQUARE FEET (1.56 ACRES) - 47% OF LOT 27,124 SQUARE FEET (0.49 ACRES) - 19% OF LOT UNDERGROUND SYSTEM 6,021 SQUARE FEET (0.14 ACRES) - 4% OF LOT NA 3780 East 15th Street, Suite 201 Loveland, Colorado 80538 970.669.8220 E-mail: info@hauserarchitectspc.com HauserArchitectspc.com SHEET Hauser Architects, P.C. 3/15/2019 10:24:57 AM CONIFER AND RED CEDAR CIRCLE AFFORDABLE STORAGE OF FORT COLLINS COVER SHEET A1 Project Development Plan (PDP) SHEET NUMBER SHEET NAME A1 COVER SHEET A2 ARCHITECTURAL SITE PLAN A3 ARCHITECTURAL SITE DETAILS A4 BUILDING A ELEVATIONS A5 BUILDING B & C ELEVATIONS A6 BUILDING D & E ELEVATIONS A7 BUILDINGS F ELEVATIONS A8 PERSPECTIVES A9 DIGITAL MATERIAL BOARD L-1 LANDSCAPE PLAN L-2 LANDSCAPE NOTES AND DETAILS L-3 MITIGATION NOTES L-4 IRRIGATION PLAN L-5 IRRIGATION NOTES AND DETAILS E-1 PHOTOMETRIC PLAN E-2 PHOTOMETRIC DETAILS CONTACT: CONTACT NAME: PH: ARCHITECT: HAUSER ARCHITECTS PC 3780 EAST 15TH STREET LOVELAND, CO 80538 970.669.8220 AL HAUSER al@hauserarchitectspc.com CONTACT: CONTACT NAME: PH: CIVIL ENGINEER: NORTH STAR DESIGN, INC. 700 AUTOMATION DRIVE, UNIT 1 WINDSOR, CO 80550 970.686.6939 PATRICIA KROETCH tricia@northstardesigninc.com PH: CONTACT: OWNER: RANDY AND DEB MILAN 1402 CATALPA COURT FORT COLLINS, CO 80521 970-566-0708 debmilan@aol.com AFFORDABLE STORAGE OF FORT COLLINS PROJECT DEVELOPMENT PLAN (PDP) BEING A REPLAT OF A PORTION OF LOTS 7 & 8 AND ALL OF LOT 9, BLOCK 4, REPLAT NO. 1 OF EVERGREEN PARK AND LOT 1, A MINOR SUBDIVISION PLAT OF CONIFER INDUSTRIAL PARK, ALL SITUATE IN SECTION 1, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO CONTACT: CONTACT NAME: PH: ELECTRICAL ENGINEER: BRET'S ELECTRIC, LLC 9250 BRUIN BLVD., UNIT C FREDERICK, CO 80530 720.494.8944 JUSTIN MARTIN JUSTIN@BRETSELECTRIC.COM OWNER'S CERTIFICATION The undersigned does/do herby certify that I/we are the lawful owners of real property described on this site plan and do hereby certify that I/we accept the conditions and restrictions set forth on said site plan. _____________________ Owner (signed) Date (State of _________________) (County of ________________) Subscribed and sworn to before me this ________day of _____________, 20__A.D. by WITNESS my hand and official seal. _______________________ Notary Public _________________________________________________________ Address _______________________ My Commission Expires DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES Approved by the Director of Planning of the City of Fort Collins, Colorado, this ________________ day of _____________, 20___ A.D. _________________________________________________ Director of Community Development and Neighborhood Services VICINITY MAP SHEET NOTE HEADING SITE PH: CONTACT: LANDSCAPE ARCHITECT: SITE DESIGN, LLC P.O Box 51 LOVELAND, CO 80539 970-217-9169 info@sitedesign-llc.com CONTACT: FAX: PH: GENERAL CONTRACTOR: MCCAULEY CONSTRUCTORS 650 INNOVATION CIRCLE WINDSOR, CO 80550 970-686-6300 970-686-6320 LEON@MCCAULEYCONSTRUCTORS.COM AFFORDABLE STORAGE OF FORT COLLINS UNIT SCHEDULE 2 STORY VS. SINGLE STORY TYPE COUNT UNIT AREA TOTAL UNIT AREA PERCENTAGE MIX 2 STORY 5 x 5 37 25 SF 925 SF 5.9% 5 x 10 87 50 SF 4350 SF 13.8% 5 x 12 1 60 SF 60 SF 0.2% 10 x 10 153 100 SF 15300 SF 24.2% 10 x 15 76 150 SF 11400 SF 12.0% 10 x 20 51 200 SF 10200 SF 8.1% 10 x 25 2 250 SF 500 SF 0.3% 2 STORY: 407 407 42735 SF 5 x 4 1 20 SF 20 SF 0.2% 5 x 5 5 25 SF 125 SF 0.8% 5 x 10 12 50 SF 600 SF 1.9% 9 x 20 1 180 SF 180 SF 0.2% 10 x 4 1 40 SF 40 SF 0.2% 10 x 10 47 100 SF 4700 SF 7.4% 10 x 13 4 130 SF 520 SF 0.6% 10 x 15 55 150 SF 8250 SF 8.7% 10 x 18 4 180 SF 720 SF 0.6% 10 x 20 65 200 SF 13000 SF 10.3% 10 x 21 5 210 SF 1050 SF 0.8% 10 x 25 19 250 SF 4750 SF 3.0% 10 x 30 3 300 SF 900 SF 0.5% 15 x 15 1 225 SF 225 SF 0.2% 15 x 25 1 375 SF 375 SF 0.2% 35 x 20 1 700 SF 700 SF 0.2% : 225 225 36155 SF Grand total: 632 632 78890 SF REVISIONS PDP Submittal 01.31.2017 PDP Submittal #5 08.10.2018 FDP Submittal #2 03.15.2019 1 PDP Submittal #2 03.28.2017 2 PDP Submittal #3 12.13.2017 3 PDP Submittal #4 02.16.2018