Loading...
HomeMy WebLinkAboutMASON PLACE - FDP190005 - SUBMITTAL DOCUMENTS - ROUND 2 - PHOTOMETRIC PLANST ST S S S M STAIR 2 ELEV. STAIR 3 FIRE ACCESS EASEMENT, 150' MAX SOUTH MASON STREET CREGER DRIVE 60' EASEMENT 30' EASE,EMT 5'-0" SIDE SETBACK FIRE ACCESS EASEMENT, 150' MAX PROPRTY LINE NEW WATER LINES, RE: CIVIL EXISTING WATER LINE EXISTING SANITARY SEWER EXISTING STORM SEWER OVERHEAD ELECTRIC LINES FORMER EASEMENT EXISTING STORM SEWER EXISTING SANITARY SEWER EXISTING GAS LINE EXISTING GAS LINE EXISTING STORM SEWER NEW STORM SEWER PIPE EASEMENT 21'-0" NEW STORM SEWER PIPE PROPRTY LINE LOT 6 LOT 5B LOT 5A FIRE LANE KEEP CLEAR FIRE LANE KEEP CLEAR WATER ENTRY STAIR 1 9 3 12'-0" EASEMENT DUMPSTER ROOM FIRE ACCESS EASEMENT 26'-0" 26'-0" FIRE ACCESS EASEMENT 7 4 5 PLANTINGS 1 FIXTURE TYPE SE1/SE1HS N.T.S. 4 FIXTURE TYPE SE4 2 FIXTURE TYPE SE2 N.T.S. N.T.S. 3 FIXTURE TYPE SE3/SE3A N.T.S. Luminaire Schedule Symbol Label Manufacturer Catalog Number Description Lamp Number Lamps Lumens Per Lamp Light Loss Factor Wattage SE1 LSI INDUSTRIES, INC XALM-3-LED-SS-30 1 17558.06 0.8 154.1 SE1HS LSI INDUSTRIES, INC XALM-3-LED-SS-30-IL 1 14555.72 0.8 154.1 SE2 LSI INDUSTRIES XBVR-ID-LED-24-400-WW- UE 1 855.903 0.9 38 SE3 Kenall FN15L-4-7-DB-47L40K8- DCC-DV L-4192-V1 48 126.8795 0.8 53.7 SE3A Kenall FN15L-2-7-DB-36L40K8- DCC-DV L-4192-V1 24 166.0168 0.8 40.71 SE4 LSI INDUSTRIES, INC LCD6-20-LED-30-52-TR6R- HZ 1 2025.47 0.9 23 ARCHITECTURAL AREA LIGHT, LED, TYPE 3 OPTICS, POLE MOUNTED 20'-0" AFG. BOLLARD, LED GROUND MOUNTED 42" AFG. WALL MOUNT LED TYPE 4 OPTICS WALL MOUNTED 13'-0" AFG RECESSED DOWNLIGHT LED 6" APERTURE ARCHITECTURAL AREA LIGHT, LED, TYPE 3 OPTICS, POLE MOUNTED 20'-0" AFG. HOUSE SIDE SHIELD WALL MOUNT LED TYPE 2 OPTICS WALL MOUNTED 10'-0" AFG J:\2018\2018-035-00\Cad\Elec\PH-SITE LIGHTING DETAILS.dwg jonk 04.03.19 7:08 am DRAWING NUMBER: 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE Plotted By: Jonk Layout: Layout1 Printed On: 4/3/2019 7:08 AM File Name: PH-SITE LIGHTING DETAILS.dwg ORIGINAL SIZE 24X36 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION RIPLEY DESIGN INC. 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 HOUSING CATALYST 1715 W. Mountain Avenue Fort Collins, CO 80521 p. 970.416.2910 ENGINEER ARCHITECT APPLICANT JVA INC. CONSULTING ENGINEERS 213 Linden Street, Suite 200 Fort Collins, CO 80524 p. 970.225.9099 SHOPWORKS 2882 Wyandot Street. Denver, CO 80211 p. 303.433.4094 OWNER J:\2018\2018-035-00\Cad\Elec\PH-SITE LIGHTING DETAILS.dwg jonk 04.03.19 7:08 am MAJOR AMENDMENT MASON PLACE PSH 1 MAJOR AMENDMENT 04.25.2018 FORT COLLINS, CO MV JK 2018-035-00 2 MAJOR AMENDMENT 2 05.15.2018 3 P&Z REVISIONS 05.31.2019 4 FDP 1 02.20.2019 5 FDP 2 4.3.2019 11 OF 11 SITE LIGHTING DETAILS CANOPY ABOVE 150' HOSE PULL 150' HOSE PULL BIKE ROOM HOT ROOM GENERAL NOTES 1. ANY PROPOSED LIGHT FIXTURES INSTALLED ON PRIVATE PROPERTY, ADJACENT TO THE PUBLIC ROW, SHALL BE ORIENTED IN SUCH A MANNER OR LIMITED IN LUMEN OUTPUT TO PREVENT GLARE PROBLEMS AND SHALL NOT EXCEED NATIONAL I.E.S. LIGHTING STANDARDS FOR DISABILITY GLARE. SINGLE OR DOUBLE HEAD LUMINAIRE GROUNDING STUD WITH #8 CU GROUNDING WIRE TO REBAR 8'-0" 2'-6" 24" #3 TIES 3" FROM TOP TOP OF FINISH GRADE. CONDUIT RISER, QUANTITY AS REQ'D. #3 HORIZ. BARS @ 12" O.C. 8#7, or 6#8 VERT BARS 1 #10 STRANDED TO LIGHTING FIXTURE 4" X 8" HANDHOLE IN LINE FUSE HOLDER 17'-6" BASE DEPTH SHALL BE FIELD VERIFIED WITH STRUCTURAL/CIVIL ENGINEER BASE ON ONSITE SOIL CONDITIONS AND FIXTURE ASSEMBLY EPA RATING. 2 SE1 PARKING POLE BASE DETAIL N.T.S. 1 SITE PHOTOMETRIC PLAN SCALE: 1" = 20'-0" SE1HS SE1 SE1 SE3 SE3 SE3A SE3A SE3A SE3 SE3 SE2 SE2 SE2 SE2 SE2 SE2 SE2 SE2 SE2 SE4 SE4 SE4 SE4 SE4 SE4 SE4 SE4 EXISTING SITE POLE SHOWN FOR REFERENCE LUMEN OUTPUT NOT INCLUDED IN CALCULATION. 0.0 0.1 0.3 0.4 0.0 0.1 0.5 0.9 0.9 0.6 0.2 0.0 0.0 0.0 0.0 0.0 0.1 0.7 1.7 1.6 1.3 0.6 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.0 2.4 2.2 1.7 0.9 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 1.4 3.6 2.9 2.2 1.1 0.5 0.3 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.2 1.8 4.2 3.8 3.6 1.8 1.1 0.6 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 2.1 4.1 3.6 2.2 3.3 2.1 0.9 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 2.4 4.1 3.8 2.3 3.3 2.3 1.9 1.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 2.4 4.2 3.8 3.2 1.7 1.2 1.7 1.2 0.3 0.2 0.1 0.1 0.1 0.4 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.3 2.1 3.2 2.5 1.9 0.8 0.6 0.4 0.3 0.4 1.6 0.2 0.2 0.2 8.1 0.7 1.0 0.5 0.1 0.1 0.0 0.0 0.1 0.1 0.1 0.3 0.4 0.2 0.2 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 1.6 2.5 2.2 1.8 0.8 0.5 1.2 1.0 0.5 3.0 1.5 3.9 0.2 0.3 0.3 2.4 0.9 9.4 0.6 0.1 0.0 0.1 0.1 0.2 0.6 0.9 0.8 0.6 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.4 1.4 1.9 2.3 2.2 1.2 0.2 1.3 1.1 7.5 1.1 0.5 4.9 0.3 4.5 1.7 0.1 0.2 0.5 0.3 0.1 0.1 0.3 0.3 0.4 0.9 1.7 1.6 1.4 0.6 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.2 0.5 1.3 1.7 2.2 3.2 4.6 0.1 0.1 0.2 0.4 0.3 0.3 1.7 0.3 1.1 3.5 0.6 5.8 0.7 2.4 0.6 1.7 2.1 2.9 2.0 4.7 3.4 5.6 3.5 3.0 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.2 0.6 1.7 2.1 2.9 4.1 8.2 3.9 0.7 6.5 1.4 6.0 1.8 7.5 5.9 6.7 2.8 5.4 4.5 6.8 4.2 3.7 1.0 0.9 0.5 0.3 0.1 0.1 0.0 0.0 0.0 0.0 0.3 1.0 1.9 2.6 3.9 5.0 6.5 7.6 6.1 2.4 2.0 4.4 4.1 4.0 2.6 2.2 2.0 1.4 0.9 0.3 0.1 0.1 0.0 0.0 0.0 0.6 1.2 2.4 3.3 4.9 5.1 8.7 7.3 5.6 3.3 2.5 4.8 4.2 3.3 3.8 3.8 3.4 2.4 1.9 0.7 0.2 0.1 0.1 0.0 0.0 1.4 2.1 3.9 4.3 5.7 5.3 8.7 8.5 7.5 4.3 4.4 7.0 6.7 5.7 6.0 6.0 5.4 3.6 2.6 1.1 0.3 0.1 0.1 0.0 0.0 2.5 3.4 2.5 4.2 5.8 5.6 6.6 8.2 8.1 5.4 5.7 9.1 8.6 8.4 7.1 7.0 7.3 5.3 3.6 1.2 0.3 0.1 0.0 0.0 0.0 2.3 3.2 2.9 4.3 5.6 5.2 8.6 7.1 7.0 5.3 5.0 8.3 8.3 7.5 6.3 5.8 6.8 5.6 4.1 1.3 0.4 0.1 0.1 0.0 0.0 1.2 2.0 3.8 4.3 5.7 5.2 6.5 8.7 8.1 4.9 4.3 7.3 7.6 7.2 6.3 5.1 6.1 5.1 2.6 1.3 0.5 0.1 0.1 0.0 0.0 0.5 1.2 2.3 3.3 4.8 4.9 8.7 8.6 7.3 4.9 4.1 6.4 7.5 7.6 5.7 5.1 6.4 5.3 3.6 1.4 0.5 0.2 0.1 0.0 0.0 0.3 1.0 1.9 2.6 3.7 4.6 8.6 9.7 5.9 5.0 5.3 7.6 8.6 8.8 7.9 7.5 8.4 6.7 4.7 1.9 0.7 0.3 0.1 0.0 0.0 0.1 0.5 1.4 1.9 3.0 4.5 6.4 7.9 6.2 5.4 6.3 7.9 8.7 8.9 8.8 9.3 9.5 6.9 4.8 2.3 0.7 0.2 0.1 0.0 0.0 0.1 0.2 0.6 1.1 1.9 3.6 8.1 9.0 5.4 4.2 4.8 5.5 6.8 7.4 7.1 7.6 7.5 5.3 4.1 1.9 0.5 0.1 0.0 0.0 0.0 0.0 0.1 0.3 0.6 1.3 2.9 4.6 9.2 4.0 2.3 2.4 2.3 3.1 3.8 2.9 4.0 4.4 3.1 2.7 1.2 0.3 0.1 0.0 0.0 0.0 0.0 0.1 0.2 0.5 1.3 2.6 4.9 8.2 7.1 8.8 9.7 7.6 9.5 7.6 9.0 9.8 7.7 9.4 7.6 8.9 9.6 7.4 8.4 7.1 3.8 1.7 1.0 0.9 0.9 1.3 1.4 1.6 1.3 1.0 0.7 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.3 0.7 0.9 1.5 2.0 2.1 2.6 2.6 2.3 2.4 2.5 2.7 2.6 2.3 2.4 2.4 2.6 2.5 2.0 1.9 2.1 1.3 1.0 0.5 0.3 0.3 0.4 0.5 0.5 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.2 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 SE3 SE3 SE3 SE3A SE3A SE3A SE3A SE3 SE3 SE3 SE1 SE1HS SE1 SE1 Statistics Description Symbol Avg Max Min Max/Min Avg/Min Avg/Max Calc Zone #1 2.0 fc 9.8 fc 0.0 fc N/A N/A 0.2:1 SE2 DRAWING NUMBER: 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE Plotted By: Jonk Layout: Layout1 Printed On: 4/3/2019 7:08 AM File Name: PH-PHOTOMETRIC.dwg ORIGINAL SIZE 24X36 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION RIPLEY DESIGN INC. 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 HOUSING CATALYST 1715 W. Mountain Avenue Fort Collins, CO 80521 p. 970.416.2910 ENGINEER ARCHITECT APPLICANT JVA INC. CONSULTING ENGINEERS 213 Linden Street, Suite 200 Fort Collins, CO 80524 p. 970.225.9099 SHOPWORKS 2882 Wyandot Street. Denver, CO 80211 p. 303.433.4094 OWNER C:\Users\jonk\appdata\local\temp\AcPublish_22820\PH-PHOTOMETRIC.dwg jonk 04.03.19 7:08 am MAJOR AMENDMENT MASON PLACE PSH 1 MAJOR AMENDMENT 04.25.2018 FORT COLLINS, CO MV JK 2018-035-00 2 MAJOR AMENDMENT 2 05.15.2018 3 P&Z REVISIONS 05.31.2019 4 FDP 1 02.20.2019 5 FDP 2 4.3.2019 10 OF 11 NORTH 0 10 20 40 SCALE: 1"=20'-0" SITE PHOTOMETRIC