Loading...
HomeMy WebLinkAboutFTC MO JEAUX WTE VERIZON - BDR180026 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC MO JEAUX SC 1409 W ELIZABETH ST FORT COLLINS, COLORADO 80521 NEW ROOFTOP MACRO ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: HEAD SOUTH TOWARD S VAUGHN WAY. MERGE ONTO I-225 N. TAKE EXIT 12A TO MERGE ONTO I-70 W. KEEP RIGHT AT THE FORK TO CONTINUE ON I-270 W. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FORT COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W/E MULBERRY ST TOWARD FORT COLLINS. MERGE ONTO CO-14 W/E MULBERRY ST. CONTINUE STRAIGHT ONTO W MULBERRY ST. TURN LEFT ONTO CITY PARK AVE. TURN RIGHT ONTO W ELIZABETH ST. DESTINATION WILL BE ON THE LEFT IN 328 FT. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 1409 ELIZEBETH LLC CONTACT: PHILIP SCHUMAN PHONE: 970-219-9965 3977 CAMINO RANCHERO CAMARILLO, CA 93012 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: KENT McDERMOTT EMAIL: KENT.MCDERMOTT@VERIZONWIRELESS.COM AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT STREET, UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB GENERAL NOTES GN-1 2 GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 05/04/18. 2. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 4. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 6. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 7. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 13. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. 14. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 15. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 16. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 17. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 18. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 19. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 20. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: GENERAL NOTES (CONTINUED) GN-2 3 REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 3-4 5-9 10-14 15-19 OVER 19 1 2 5 10 12 15 STREET TREE NOTES: 1. A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. 2. CONTACT THE CITY FORESTER TO INSPECT ALL STREET TREE PLANTINGS AT THE COMPLETION OF EACH PHASE OF THE DEVELOPMENT. ALL MUST BE INSTALLED AS SHOWN ON THE LANDSCAPE PLAN. APPROVAL OF STREET TREE PLANTING IS REQUIRED BEFORE FINAL APPROVAL OF EACH PHASE. REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTHWEST) SCALE: N.T.S. 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING SOUTHWEST) SCALE: N.T.S. 3 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTH) SCALE: N.T.S. 3 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING SOUTH) SCALE: N.T.S. PHOTOSIMULATIONS PH-1 4 REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING 1 PH-2 PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST) SCALE: N.T.S. 2 PH-2 PHOTOSIMULATION VIEW (AFTER, LOOKING EAST) SCALE: N.T.S. PHOTOSIMULATIONS (CONTINUED) PH-2 5 D S Y WV WV WM S WV WM ET GM SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W SS SS W W W W SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD TV TV TV TV TV TV TV TV TV TV UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE U E UE UE UE UE SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD W W W W W W W E F F F F F F F F F F F F F EXISTING 10'-0" DRAINAGE EASEMENT EXISTING 12'-0" UTILITY EASEMENT EXISTING 10'-0" UTILITY EASEMENT PROPOSED 20'-0" EAE WM W W W W RD F F F F F F F F F F F F F F F F F F F F F F F F F F F R D SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD R D RD F F F REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING PROPOSED CHASE TO ROOFTOP (PAINT TO MATCH EXISTING DOWNSPOUTS) PROPOSED VERIZON ANTENNA MOUNTED TO NEW ANTENNA FRAME (3 PER SECTOR, 12 TOTAL) PROPOSED HYBRID RUN FROM EQUIPMENT CABINET TO ROOFTOP OVP'S PROPOSED ROOFTOP CABLE TRAY FOR HYBRID AND FIBER RUN PROPOSED VERIZON RRH MOUNTED TO BOTTOM OF ANTENNA MOUNT 33'-0" 36'-7" 39'-0" 47'-0" 46'-0" 43'-0" 36'-7" 39'-0" 33'-0" 47'-0" 42'-0" 46'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING PROPOSED VERIZON ANTENNA MOUNTED TO BACK OF PARAPET WALL (3 PER SECTOR, 12 TOTAL) TOP OF PARAPET 36'-7" AGL TOP OF ROOF 33'-0" AGL 97'-9" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING PROPOSED LINE OF SIGHT FROM 5'8" PERSON IN THE MIDDLE OF THE SIDEWALK ACROSS W ELIZABETH AVENUE L.O.S. NOTE: THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS A VISUAL REPRESENTATION OF HOW THE SITE WOULD APPEAR TO A 5' 8" PERSON STANDING ON THE SIDEWALK ACROSS WEST ELIZABETH AVE WEST ELIZABETH AVENUE PROPOSED ANTENNA CONCEALMENT SCREEN (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) PROPOSED ANTENNA CONCEALMENT SCREEN (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) PROPOSED VERIZON ANTENNA MOUNTED TO BACK OF PARAPET WALL (3 PER SECTOR, 12 TOTAL) 2 Z-4 PERSPECTIVE ELEVATION SCALE: N.T.S. 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 241'-3" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING PROPOSED LINE OF SIGHT FROM 5'8" PERSON STANDING IN THE PARKING LOT IN FRONT OF THE 7-ELEVEN EAST OF THE PROPOSED BUILDING L.O.S. NOTE: THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS A VISUAL REPRESENTATION OF HOW THE SITE WOULD APPEAR TO A 5' 8" PERSON STANDING IN THE PARKING LOT IN FRONT OF THE 7-ELEVEN EAST OF THE PROPOSED BUILDING LOCATION. PROPOSED ANTENNA CONCEALMENT SCREEN (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) (TYP) (2) PROPOSED EQUIPMENT CABINETS MOUNTED ON ROOF 2 Z-5 PERSPECTIVE ELEVATION SCALE: N.T.S. 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 Z-5 LINE OF SIGHT ELEVATION 12'-1" 10'-1" 10'-2" 9'-0" 11'-0" 12'-2" 10'-2" 9'-10" RD F F F F F F F F F F F F F F 3'-3" 17'-8" 10'-2" 3'-3" SD SD SD 3'-3" 10'-2" 17'-8" 3'-3" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING SCREEN DETAILS Z-6 11 1 Z-6 ANTENNA SCREEN - SECTOR A & D N.T.S. REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING 1 Z-7 ANTENNA SCREEN COLOR SAMPLE N.T.S. MAIN FIBERGLASS SCREEN: SMOOTH STUCCO PAINTED TO MATCH LIGHT TAN OF EXISTING BUILDING WALLS FASCIA TRIM OF NEW SCREEN TO MATCH LIGHT SILVER COLOR OF EXISTING GUTTER/BUILDING TRIM MATERIAL REFERENCES Z-7 12 REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING M LOAD CENTER PROPOSED 200A LOAD CENTER PANEL CIRCUIT AND LOAD SCHEDULE LOAD LOAD PER PHASE (VA) PHASE A B DESCRIPTION 1 3 5 QTY. UNIT V.A. 1400 LOADS CONTINUOUS LOADS N0N-CONTINUOUS WIRE SIZE 7 9 11 1400 SUBTOTAL CONTINUOUS S Y WV WV WV WM GM SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W SS SS SS SS W W W W W W W W X X R D SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD W W W W W F F F F F F F F F F F ET SD SD SD SD SD SD SD TV TV UE UE UE UE UE UE UE UE UE UE SD SD SD SD SD SD SD SD S SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD D SD SD SD SD SD SD SD SD SD SD X X X X X X X X X X X X E E REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: RD D S Y WV WV WM S WV WM ET GM SS SS SS SS SS SS SS SS SS SS SS SS W W SS W W SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD TV TV TV TV TV TV U E UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD X X X X X X X X X X X X X X X X X X X X R D RD RD RD SD SD SD SD SD SD SD SD SD SD W W W W F F F F F F F RD D S Y WV WV WM S WV WM ET GM SS SS SS SS SS SS SS SS SS SS SS SS W W SS W W SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD TV TV TV TV TV TV UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD X X X X X X X X X X X X X X X X X X X X R D RD RD RD SD SD SD SD SD SD SD SD SD SD W W W W REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING 1 Z-10 LANDSCAPING PLAN - EXISTING SCALE: 1/16"=1'-0" 2 Z-10 LANDSCAPING PLAN - PROPOSED SCALE: 1/16"=1'-0" LANDSCAPE PLAN Z-10 15 EXISTING LANDSCAPING EXISTING 51'-0"± HONEYLOCUST 16", FAIR PLUS CONDITION, MITIGATION VALUE: 1.5; REMAIN EXISTING 10'-0"± HONEYLOCUST 2", DEAD, MITIGATION VALUE: 0; REMAIN EXISTING 28'-0"± HONEYLOCUST 10", FAIR CONDITION, MITIGATION VALUE: 1; REMAIN EXISTING 30'-0"± BLUE SPRUCE 13", GOOD CONDITION, MITIGATION VALUE: 1.5; REMAIN EXISTING OFF SITE TREES; TO REMAIN NOTE: - A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. - ALL EXISTING TREES TO REMAIN AND BE PROTECTED. EXISTING PROPETY LINE EXISTING CURB EXISTING BUILDING EXISTING PARKING LOT 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 16 0 8 16 32 64 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 16 0 8 16 32 64 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING LANDSCAPING EXISTING 51'-0"± HONEYLOCUST 16", FAIR PLUS CONDITION, MITIGATION VALUE: 1.5; REMAIN EXISTING 10'-0"± HONEYLOCUST 2", DEAD, MITIGATION VALUE: 0; REMAIN EXISTING 28'-0"± HONEYLOCUST 10", FAIR CONDITION, MITIGATION VALUE: 1; REMAIN EXISTING 30'-0"± BLUE SPRUCE 13", GOOD CONDITION, MITIGATION VALUE: 1.5; REMAIN EXISTING PROPETY LINE EXISTING CURB EXISTING BUILDING EXISTING PARKING LOT CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING EXISTING 15" RCP STORM MAIN. TOP OF PIPE BURIED APROX. 45" B.F.G (CONTRACTOR TO VERIFY) 1 Z-9 UTILITY PLAN SCALE: 3/32"=1'-0" UTILITY COORDINATION Z-9 14 UTILITY PLAN SCHEDULE QUANTITY 1 POWER NOTES: 1. SERVICE SHALL BE 120/208V, 1Ø, 3W, 100A 2. CONTRACTOR TO COORDINATE INSPECTION AND PLACEMENT OF METER WITH THE LOCAL UTILITY COMPANY: FTC L&P CONTACT: AUSTIN KREAGER PHONE: 790-224-6152 W.O. NUMBER: TBD ITEM LENGTH PROVIDED BY INSTALLED BY TRANSFORMER - FTC L&P FTC L&P DESCRIPTION EXISTING 120/208V, 3Ø, 3W, 75kVA 1 CONDUITS - LINE TO METER 3" EMT 100'± CONTRACTOR 3 CONDUCTORS - LINE TO METER (3) 3/0 CU CONDUCTORS 100'± CONTRACTOR CONTRACTOR CONTRACTOR 1 DISCONNECT - CONTRACTOR LEVER-TYPE 100A FUSED CONTRACTOR 1 METER SOCKET TYP - CONTRACTOR CONTRACTOR 1 METER TYP - FTC L&P FTC L&P 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 8 16 24 32 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED NEW POWER SERVICE ROUTED IN 3" EMT CONDUIT FROM EXISTING TRANSFORMER TO NEW METER MOUNTED TO EXTERIOR OF WALL EXISTING BUILDING EXISTING TRANSFORMER PROPOSED 200A METER MOUNTED TO EXTERIOR WALL EXISTING BUILDING PROPOSED 2'-0"x3'-0" FIBER VAULT PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED 10' WIDE UTILITY EASEMENT PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT TO MMP IN R.O.W. PROPOSED 10' WIDE UTILITY EASEMENT SUBTOTAL NON-CONTINUOUS - VOLTAGE: 120/240 CYCLE: 60 PHASE: 1 WIRE: 3 NEUTRAL: 200 AMPS MAIN BREAKER: 200 AMP FRAME MAIN LUGS: N/A MAINS: TOP BOTTOM A.I.C.: 22,000 TRIP: 200 AMPS MAIN COPPER BUS: 200 AMPS X SERVICE: DESIGNATION: LOCATION: 2 4 6 8 10 12 SUBTOTAL CONTINUOUS SUBTOTAL NON-CONTINUOUS - MANUFACTURER: SQUARE D 120/240 VAC PANEL SCHEDULE PANEL 1400 MODEL NUMBER: UNKNOWN NO EQUAL: APPROVED EQUAL: MOUNTING: SURFACE: FLUSH: X X TOTAL KVA CONTINUOUS x 1.25 TOTAL KVA NON-CONTINUOUS TOTAL KVA TOTAL AMPS 33.68 0 33.68 140.31 BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED 200A S G S N 3/0 #6 120/240 VAC 1Ø 200 AMP SERVICE SUPPLIED & INSTALLED BY SITE ELECTRICAL CONTRACTOR 1400 13 15 17 19 21 23 14 16 18 20 22 1 24 2 BLK RED BLK RED BLK RED BLK RED BLK RED BLK RED 1 7,600 - RECTIFIER #1 1400 1400 1400 1400 5,660 5,780 - 25 27 29 26 28 30 BLK RED BLK RED BLK BLK RECTIFIER #2 X LOADS SUB-PANEL GROUNDING WIRE SIZE TRIP LOAD PER PHASE (VA) LOAD PHASE A B DESCRIPTION QTY. UNIT V.A. 1400 LOADS CONTINUOUS LOADS N0N-CONTINUOUS WIRE SIZE 1400 1400 1400 1400 1000 1000 1000 1000 HVAC #1 1400 1 RECTIFIER #5 1400 LOADS SUB-PANEL GROUNDING WIRE SIZE TRIP RECTIFIER #3 1400 1400 1400 1400 RECTIFIER #4 - - 1400 1400 1400 1400 - 360 10 (10) 30 X 10 (10) 30 X 10 (10) 30 X 10 (10) 30 30 (10) 10 1400 1400 1400 1400 1400 30 (10) 10 GFCI RECEPTACLES X X 30 (10) 10 X 30 (10) 10 X RECTIFIER #6 RECTIFIER #7 RECTIFIER #8 - - - - - - - - - SPARE SPARE SPARE SPARE - 180 X X X 12 (12) 20 12 20 7,600 SPARE TELCO BOX RECEP. - SPARE SPARE - 180 - - - - 180 - - - 1 1 1 20 (12) 12 X 20 (12) 12 X HVAC #2 1 1 1 1 1 (12) 1400 1400 1400 1400 1000 1000 1000 1000 X X X X 12 (12) 20 EXISTING 120/208 V 3Ø 75kVA TRANSFORMER (FAULT = TBD) PROPOSED 3" PVC CONDUIT WITH (3) 3/0 CU CONDUCTORS PROPOSED 200A LEVER-TYPE DISCONNECT (FAULT = TBD) PROPOSED 200A METER PROPOSED 200A LEVER-TYPE DISCONNECT PROPOSED 3" EMT CONDUIT WITH (3) 3/0 CU CONDUCTORS & (1) #6 CU GROUND 1 Z-8 ONE-LINE DIAGRAM N.T.S 2 Z-8 PANEL SCHEDULE N.T.S ONE-LINE DIAGRAM & PANEL SCHEDULE Z-8 13 PROPOSED NEW POWER SERVICE FROM EXISTING TRANSFORMER 4 Z-6 ANTENNA SCREEN - SECTOR B & C N.T.S. Z-6 3 3 Z-6 ANTENNA SCREEN - SECTOR A & D N.T.S. 2 Z-6 ANTENNA SCREEN - SECTOR B & C N.T.S. Z-6 4 PROPOSED ANTENNA CONCEALMENT WALL (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) PROPOSED OVP MOUNTED TO BACK OF PARAPET WALL (4 TOTAL) EXISTING ELEVATOR SHAFT PROPOSED VERIZON ANTENNA MOUNTED TO BACK OF PARAPET WALL (3 PER SECTOR, 12 TOTAL) PROPOSED VERIZON RRH MOUNTED TO BOTTOM OF ANTENNA MOUNT (12 TOTAL) SCALE: 1/8"=1'-0" LOS ELEVATION II Z-5 10 (2) PROPOSED EQUIPMENT CABINETS MOUNTED ON ROOF 1 Z-4 LINE OF SIGHT ELEVATION SCALE: 1/8"=1'-0" LOS ELEVATION I Z-4 9 PROPOSED VERIZON RRH MOUNTED TO BOTTOM OF ANTENNA MOUNT (3 PER SECTOR, 12 TOTAL) TOP OF PROPOSED VERIZON ANTENNA 46'-0" AGL PROPOSED VERIZON RAD CENTER (B&C) 43'-0" AGL GRADE 0'-0"± AGL PROPOSED OVP MOUNTED TO BACK OF PARAPET WALL (4 TOTAL) TOP OF PROPOSED ANTENNA CONCEALMENT 47'-0" AGL PROPOSED FIBER RUN UP SIDE OF BUILDING IN CHASE (PAINT TO MATCH EXISTING DOWNSPOUTS) PROPOSED ANTENNA CONCEALMENT SCREEN (TYP) (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) GRADE 0'-0"± AGL TOP OF STURCTURE 39'-0" AGL TOP OF STURCTURE 39'-0" AGL TOP OF PARAPET 36'-7" AGL TOP OF ROOF 33'-0" AGL 2 Z-3 PROPOSED EAST ELEVATION SCALE: 1/8"=1'-0" 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1 Z-3 EXISTING EAST ELEVATION SCALE: 1/8"=1'-0" ELEVATIONS Z-3 8 TOP OF PROPOSED VERIZON ANTENNA (A&D) 46'-0" AGL PROPOSED VERIZON RAD CENTER 42'-0" AGL TOP OF PROPOSED ANTENNA CONCEALMENT 47'-0" AGL PROPOSED 8' PANEL ANTENNA (TYP, 3 PER SECTOR - A & D SECTORS) (6) PROPOSED 6' PANEL ANTENNAS (SECTOR B & C ONLY) (2) PROPOSED EQUIPMENT CABINETS MOUNTED ON ROOF (PAINT TO MATCH PRIMARY BUILDING COLOR) (12 TOTAL) SECTOR D VZW ANTENNA AZ= 330° SECTOR A VZW ANTENNA AZ= 60° SECTOR B VZW ANTENNA AZ=150° SECTOR C VZW ANTENNA AZ= 240° PROPOSED OVP MOUNTED TO ANTENNA FRAME (4 TOTAL) PROPOSED EQUIPMENT CABINET (TYP OF 2) PROPOSED ELECTRIC TO BE PULLED FROM EXISTING ELECTRIC ROOM IN BUILDING PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT ON ROOFTOP A SECTOR CABLE TABLE 60° AZIMUTH 75' LENGTH 1 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 6x12 HYBRIFLEX C D 240° 330° HYBRIFLEX HYBRIFLEX 6x12 6x12 1 1 70' 135' 150' N 1 Z-2 EQUIPMENT PLAN SCALE: 3/16"=1'-0" 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 6 8 10 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 Z-3 EXISTING BUILDING EXISTING ELEVATOR SHAFT EXISTING ACCESS HATCH EQUIPMENT PLAN Z-2 7 B 150° 1 6x12 HYBRIFLEX EXISTING BUILDING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING W ELIZEBETH ST PROPOSED 2'-0"x3'-0" FIBER VAULT PROPOSED VERIZON ANTENNA MOUNTED NEW ANTENNA FRAME BEHIND SCREEN (TYP 3 PER SECTOR, 12 TOTAL) PROPOSED EQUIPMENT CABINET (TYP OF 2) PROPOSED ANTENNA CONCEALMENT WALL (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED OVP MOUNTED TONEW ANTENNA FRAME (4 TOTAL) PROPOSED FIBER ROUTED UP SIDE OF BUILDING IN CHASE TO MATCH EXISTING DOWNSPOUT EXISTING ELEVATOR SHAFT EXISTING ACCESS HATCH 2 Z-4 PROPOSED ELECTRIC TO BE PULLED FROM EXISTING ELECTRIC ROOM IN BUILDING PROPOSED 10' WIDE UTILITY EASEMENT PROPOSED 10' WIDE ACCESS EASEMENT PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT TO MMP IN R.O.W. N 1 Z-1 SITE PLAN SCALE: 1"=20'-0" NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. 1 inch = 20ft. ( IN FEET ) GRAPHIC SCALE 20 0 10 20 40 80 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) SITE PLAN Z-1 6 2 Z-3 PROPOSED 20'-0" WIDE EMERGENCY ACCESS EASEMENT EXISTING TRANSFORMER PROPOSED 10' WIDE UTILITY EASEMENT PROPOSED 200A METER MOUNTED TO EXTERIOR WALL PROPOSED NEW POWER RUN FROM EXISTING TRANSFORMER TO NEW METER MOUNTED TO EXTERIOR OF WALL 3. STREET LANDSCAPING, INCLUDING STREET TREES, SHALL BE SELECTED IN ACCORDANCE WITH ALL CITY CODES AND POLICIES. ALL TREE PRUNING AND REMOVAL WORKS SHALL BE PERFORMED BY A CITY OF FORT COLLINS LICENSED ARBORS WHERE REQUIRED BY CODE. STREET TREES SHALL BE SUPPLIED AND PLANTED BY THE DEVELOPER USING A QUALIFIED LANDSCAPE CONTRACTOR. 4. THE DEVELOPER SHALL REPLACE DEAD OR DYING STREET TREES AFTER PLANTING UNTIL FINAL MAINTENANCE INSPECTION AND ACCEPTANCE BY THE CITY OF FORT COLLINS FORESTRY DIVISION. ALL STREET TREES IN THE PROJECT MUST BE ESTABLISHED, WITH AN APPROVED SPECIES AND OF ACCEPTABLE CONDITION PRIOR TO ACCEPTANCE. 5. SUBJECT TO APPROVAL BY THE CITY FORESTER - STREET TREE LOCATIONS MAY BE ADJUSTED TO ACCOMMODATE DRIVEWAY LOCATIONS, UTILITY SEPARATIONS BETWEEN TREES, STREET SIGNS AND STREET LIGHTS. STREET TREES TO BE CENTERED IN THE MIDDLE OF THE LOT TO THE EXTENT FEASIBLE. QUANTITIES SHOWN ON PLAN MUST BE INSTALLED UNLESS A REDUCTION IS APPROVED BY THE CITY TO MEET SEPARATION STANDARDS. TREE PROTECTION NOTES: 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTRUBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUISNESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (1/2) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RAHTER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. GENERAL LANDSCAPE NOTES: 1. PLANT QUALITY: ALL PLANT MATERIAL SHALL BE A-GRADE OR NO. 1 GRADE - FREE OF ANY DEFECTS, OF NORMAL HEALTH, HEIGHT, LEAF DENSITY AND SPREAD APPROPRIATE TO THE SPECIES AS DEFINED BY THE AMERICAN ASSOCIATION OF NURSERYMEN (AAN) STANDARDS. ALL TREES SHALL BE BALL AND BURLAP EQUIVALENT. 2. IRRIGATION: ALL LANDSCAPE AREAS WITHIN THE SITE INCLUDING TURF, SHRUB BEDS AND TREE AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC IRRIGATION SYSTEM. THE IRRIGATION PLAN MUST BE REVIEWED AND APPROVED BY THE CITY OF FORT COLLINS WATER UTILITIES DEPARTMENT PRIOR TO THE ISSUANCE OF A BUILDING PERMIT. ALL TURF AREAS SHALL BE IRRIGATED WITH AN AUTOMATIC POP-UP IRRIGATION SYSTEM. ALL SHRUB BEDS AND TREES, INCLUDING IN NATIVE SEED AREAS, SHALL BE IRRIGATED WITH AN AUTOMATIC DRIP (TRICKLE) IRRIGATION SYSTEM, OR WITH AN ACCEPTABLE ALTERNATIVE APPROVED BY THE CITY WITH THE IRRIGATION IRRIGATION PLANS. THE IRRIGATION SYSTEM SHALL BE ADJUSTED TO MEET THE WATER REQUIREMENTS OF THE INDIVIDUAL PLANT MATERIAL. IRRIGATION SYSTEMS TO BE TURNED OVER TO THE CITY PARKS DEPARTMENT FOR MAINTENANCE MUST BE APPROVED BY THE PARKS MANAGER AND MEET PARKS IRRIGATION STANDARDS. DESIGN REVIEW SHALL OCCUR DURING UTILITIES DEPARTMENT IRRIGATION REVIEW PRIOR TO THE ISSUANCE OF A BUILDING PERMIT AND CONSTRUCTION OBSERVATION AND INSPECTION BY PARKS SHALL BE INCORPORATED INTO THE CONSTRUCTION PROCESS. 3. TOPSOIL: TO THE MAXIMUM EXTENT FEASIBLE, TOPSOIL THAT IS REMOVED DURING CONSTRUCTION ACTIVITY SHALL BE CONSERVED FOR LATER USE ON AREAS REQUIRING REVEGETATION AND LANDSCAPING. 4. SOIL AMENDMENTS: SOIL AMENDMENTS SHALL BE PROVIDED AND DOCUMENTED IN ACCORDANCE WITH CITY CODE SECTION 12-132. THE SOIL IN ALL LANDSCAPE AREAS, INCLUDING PARKWAYS AND MEDIANS, SHALL BE TOUGHLY LOOSENED TO A DEPTH OF NOT LESS THAN EIGHT (8) INCHES AND SOIL AMENDMENT SHALL BE THOROUGHLY INCORPORATED INTO THE SOIL OF ALL LANDSCAPE AREAS TO A DEPTH OF AT LEAST SIX (6) INCHES BY TILLING, DISCING OR OTHER SUITABLE METHOD, AT A RATE OF AT LEAST THREE (3) CUBIC YARDS OF SOIL AMENDMENT PER ONE THOUSAND (1,000) SQUARE FEET OF LANDSCAPE AREA. PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY, A WRITTEN CERTIFICATION MUST BE SUBMITTED TO THE CITY THAT ALL PLANTED AREAS, OR AREAS TO BE PLANTED, HAVE BEEN THOROUGHLY LOOSENED AND THE SOIL AMENDED, CONSISTENT WITH THE REQUIREMENTS SET FORTH IN SECTION 12-132. 5. INSTALLATION AND GUARANTEE: ALL LANDSCAPING SHALL BE INSTALLED ACCORDING TO SOUND HORTICULTURAL PRACTICES IN A MANNER DESIGNED TO ENCOURAGE QUICK ESTABLISHMENT AND HEALTHY GROWTH. ALL LANDSCAPING FOR EACH PHASE MUST BE EITHER INSTALLED OR THE INSTALLATION MUST BE SECURED WITH AN IRREVOCABLE LETTER OF CREDIT, PERFORMANCE BOND, OR ESCROW ACCOUNT FOR 125% OF THE VALUATION OF THE MATERIALS AND LABOR PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY FOR ANY BUILDING IN SUCH PHASE. 6. MAINTENANCE: TREES AND VEGETATION, IRRIGATION SYSTEMS, FENCES, WALLS AND OTHER LANDSCAPE ELEMENTS WITH THESE FINAL PLANS SHALL BE CONSIDERED AS ELEMENTS OF THE PROJECT IN THE SAME MANNER AS PARKING, BUILDING MATERIALS AND OTHER SITE DETAILS. THE APPLICANT, LANDOWNER OR SUCCESSORS IN INTEREST SHALL BE JOINTLY AND SEVERALLY RESPONSIBLE FOR THE REGULAR MAINTENANCE OF ALL LANDSCAPING ELEMENTS IN GOOD CONDITION. ALL LANDSCAPING SHALL BE MAINTAINED FREE FROM DISEASE, PESTS, WEEDS AND LITTER, AND ALL LANDSCAPE STRUCTURES SUCH AS FENCES AND WALLS SHALL BE REPAIRED AND REPLACED PERIODICALLY TO MAINTAIN A STRUCTURALLY SOUND CONDITION. 7. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. 8. THE FOLLOWING SEPERATIONS SHALL BE PROVIDED BETWEEN TREES/SHRUBS AND UTILITIES: 40 FEET BETWEEN CANOPY TREES AND STREET LIGHTS. 15 FEET BETWEEN ORNAMENTAL TREES AND STREET LIGHTS. 10 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER MAIN LINES. 6 FEET BETWEEN TREES AND PUBLIC WATER, SANITARY AND STORM SEWER SERVICE LINES. 4 FEET BETWEEN SHRUBS AND PUBLIC WATER, AND SANITARY AND STORM SEWER LINES. 4 FEET BETWEEN TREES AND GAS LINES. 9. ALL STREET TREES SHALL BE PLACED A MINIMUM EIGHT (8) FEET AWAY FROM THE EDGES OF DRIVEWAYS AND ALLEYS PER LUC 3.2.1(D)(2)(a). 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING LEGEND W W SS SS SS F F F GAS GAS GAS GAS GAS OE OE UT UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD SD SD SD E E E UE UE UE OT OT OT EV D O O O U/G U/G OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING SKYLIGHT HVAC UNIT AC SECURITY CAMERA VENT PIPE VP BOLLARD COMM DISH GROUNDING NOTES: 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. 2. ALL GROUNDING DEVICES SHALL BE U.L. APPROVED OR LISTED FOR THEIR INTENDED USE. 3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE. 4. GROUND WIRES SHALL BE #2 AWG BARE SOLID COPPER UNLESS NOTED OTHERWISE. 5. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC ("CADWELDS") TO GROUND RODS, GROUND RING WIRE, AND FENCE POSTS UNLESS NOTED OTHERWISE. CLEAN SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED TO GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZED PAINT. 6. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO-HOLE BRASS MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING SCREW SET.) CLEAN GROUND BAR TO SHINY METAL AFTER MECHANICAL CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING. 7. GROUND CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING KITS. 8. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 8" RADIUS. 9. PRIOR TO INSTALLING LUGS ON GROUND WIRES, APPLY THOMAS & BETTS KOPR-SHIELD (TM OF JET LUBE, INC.) PRIOR TO BOLTING GROUND WIRE LUGS TO GROUND BARS, APPLY KOPR-SHIELD OR EQUAL. 10. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY REMOVING ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING CONNECTION, APPLY APPROPRIATE ANTI-OXIDIZATION PAINT. ELECTRICAL NOTES: 1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. ANY QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTORS FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. 2. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO ROUGH-IN. 3. THE CONDUIT RUNS AS SHOWN ON THE PLANS ARE APPROXIMATE. EXACT LOCATION AND ROUTING SHALL BE PER EXISTING FIELD CONDITIONS. 4. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY NEC. 5. ALL CONDUITS SHALL BE MET WITH BENDS MADE IN ACCORDANCE WITH NEC CHAPTER 9, TABLE #2. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER. 6. ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PLASTIC THROAT INSULATING GROUNDING BUSHINGS. 7. ALL WIRE SHALL BE TYPE THHN/THWN, SOLID, ANNEALED COPPER UP TO SIZE #10 AWG (#8 AND LARGER SHALL BE CONCENTRIC STRANDED) 75° C (167° F), 98% CONDUCTIVITY, MINIMUM #12. 8. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J-BOXES, EQUIPMENT BOXES AND CABINETS WITH APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY, OR APPROVED EQUAL. 9. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL. 10. CONDUIT ROUGH-IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTRACTOR AND COMPLY AS REQUIRED. 11. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN NOT HAND WRITTEN. 12. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL DISCONNECT SWITCHES, STARTERS, AND EQUIPMENT CABINETS. 13. THE CONTRACTOR SHALL PREPARE AS-BUILT DRAWINGS, DOCUMENT ANY AND ALL WIRING AND EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS CONTRACT. SUBMIT AT SUBSTANTIAL COMPLETION. 14. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED LAMICOID NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM (NO EXCEPTIONS.) 15. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) AS ADOPTED BY THE APPLICABLE STATE. 16. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR RISERS THROUGH BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS WITHOUT CONSTRUCTION MANAGER'S APPROVAL. SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE PACKED WITH FIRE RATED MATERIAL WHICH SHALL MAINTAIN THE FIRE RATING OF THE WALL OR STRUCTURE. FILL FOR FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. 17. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND EXISTING) SHALL BE FIELD VERIFIED WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN OF CONDUIT AND WIRE. ALL EQUIPMENT SHALL BE PROPERLY CONNECTED ACCORDING TO THE NAMEPLATE DATA FURNISHED ON THE EQUIPMENT (THE DESIGN OF THESE PLANS ARE BASED UPON BEST AVAILABLE INFORMATION AT THE TIME OF DESIGN AND SOME EQUIPMENT CHARACTERISTICS MAY VARY FROM DESIGN AS SHOWN ON THESE DRAWINGS). LOCATION OF ALL OUTLET, BOXES, ETC., AND THE TYPE OF CONNECTION (PLUG OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR TO ROUGH-IN. BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-3 EQUIPMENT PLAN PROJECT DESCRIPTION 1. INSTALL (2) NEW EQUIPMENT CABINETS ON ROOF. 2. INSTALL (12) NEW ANTENNAS ON BACK OF ROOF. 3. INSTALL (12) NEW REMOTE RADIO HEADS ON ROOF. 4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN. 5. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT. 6. INSTALL (4) HYBRID CABLES. 7. INSTALL (4) OVP'S AT ROOF LEVEL. 8. INSTALL RF TRANSPARENT SCREEN WALLS. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 JURISDICTION: CITY OF FT. COLLINS ZONING: COMMUNITY COMMERCIAL DISTRICT APN: 9715431004 PARCEL SIZE: 20,474 S.F. ELEVATION: 5043' (NAVD 88) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 39'-0"± (TOP OF STRUCTURE) ANTENNA RAD CENTER: A, B, D: 43'-0" & C: 42'-0"AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-18-0084 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 15 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W. ELIZABETH ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS SHEET NUMBER: H 07-16-18 RPH REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING I 11-06-18 GAC REVISED FINAL ZONING J 12-10-18 GAC REVISED FINAL ZONING K 01-04-19 LCW REVISED FINAL ZONING L 01-23-19 LCW REVISED FINAL ZONING M 01-31-19 GAC REVISED FINAL ZONING Z-4 ELEVATIONS LOS ELEVATION I LEGAL DESCRIPTION Z-2 LOT 2, FAIRVIEW SHOPPING CENTER FILING FOUR, COUNTY OF LARIMER, STATE OF COLORADO, CITY OF FORT COLLINS PH-1 PHOTOSIMULATIONS Z-6 MATERIAL REFERENCES PHOTOSIM LOCATION #1 PHOTOSIM LOCATION #2 PH-2 PHOTOSIMULATIONS (CONTINUED) PHOTOSIM LOCATION #3 Z-7 ONE-LINE DIAGRAM & PANEL SCHEDULE 1 PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION GN-1 GENERAL NOTES Z-8 Z-9 UTILITY COORDINATION LANDSCAPE PLAN GN-2 GENERAL NOTES (CONTINUED) Z-10 SCREEN DETAILS Z-5 LOS ELEVATION II