January 23, 2019
Josh Horner
S&J Construction Inc
6011 Maidenhead Dr
Windsor, CO 80550
RE: 622 W Laurel, BDR180040, Round Number 1
Please see the following summary of comments from City staff and outside reviewing
agencies for your submittal of the above referenced project. If you have questions about
any comments, you may contact the individual commenter or direct your questions through
the Development Review Coordinator, Tenae Beane, at 970-224-6119 or tbeane@fcgov.com.
UComment Summary:
Department: Planning Services
Contact: Clay Frickey, 970-224-6045, Ucfrickey@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 01/11/2019
01/11/2019: For approval:
It looks like the existing tree shown in the front yard is actually the street tree
located in the tree lawn between the street and the sidewalk. Please show this
tree in the correct location.
Changed on plan Comment Number: 2 Comment Originated: 01/11/2019
01/11/2019: For approval:
We'll need a different signature block on the final version of your site plan. I can
provide you with a signature block to copy so we have all of the correct
information.
Changed on plan Comment Number: 3 Comment Originated: 01/11/2019
01/11/2019: For approval:
Please add a table indicating the minimum parking required for the project and
the parking you are providing. The minimum number of parking spaces is
2
dependent on the number of bedrooms in each unit. The requirements are as
follows:
1 bedroom or less - 1.5 spaces
2 bedroom - 1.75 spaces
3 bedroom - 2 spaces
4 bedroom or more - 3 spaces
Comment Number: 4 Comment Originated: 01/11/2019
01/11/2019: For approval:
You will also need to provide documentation on the site plan indicating the
number of bedrooms in each unit. This will allow us to ensure that you can meet
Added to plan your parking requirements.
Comment Number: 5 Comment Originated: 01/11/2019
01/11/2019: Information only:
We will send you an example of site plan for a similar project so you know what
all of the elements I am requesting should look like on your final site plan.
Department: Forestry
Contact: Molly Roche, 224-616-1992, Umroche@fcgov.com
Topic: Landscape Plans
Comment Number: 1 Comment Originated: 01/14/2019
1/14/2019: FOR APPROVAL
Thank you for showing approximate locations of trees on-site. Please confirm if
there will be any planned changes to the existing landscaping or trees on the
property. If there are no plans to remove or add landscaping, please include the
no changes to the following note on the site plans: EXISTING TREES TO REMAIN.
Landscaping Comment Number: 2 Comment Originated: 01/15/2019
1/15/2019: FOR APPROVAL
It looks like one of the tree symbols is missing or incorrectly shown on the plan.
corrected There should be a tree shown in the tree lawn between the sidewalk and curb.
Comment Number: 3 Comment Originated: 01/15/2019
1/15/2019: FOR APPROVAL
Please include the City of Fort Collins Tree Protection Notes to the plans, which
Added to plans are available from City Forestry (mroche@fcgov.com).
Department: Engineering Development Review
Contact: Morgan Uhlman, 970-416-4344, Umuhlman@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 01/14/2019
01/14/2019 For Approval:
Laurel Street is identified as a 4-lane arterial on the Master Street Plan, this
requires a 15' utility easement behind the right-of-way. Please work with me and
technical services on dedicating that easement by separate document. For
more information on the process of the easement dedication process the link
3
following will have more information:
https://www.fcgov.com/engineering/devrev.php
Comment Number: 2 Comment Originated: 01/16/2019
01/05/2018: For Approval:
The Engineering department has started doing field visits to evaluate the
existing sidewalks and their conditions. It was determined that a few stones in
added to plans front of this property will need to be replaced. Please show this on your plan.
Department: Light And Power
Contact: Luke Unruh, 9704162724, Ulunruh@fcgov.com
Topic: General
Comment Number: 2 Comment Originated: 01/14/2019
01/14/2019: The current service to the existing single family is only capable of
handling 150 amps without an upgrade charge and a new service conductor
installed.
Comment Number: 1 Comment Originated: 01/14/2019
01/14/2019: The new dwelling must be metered separately from the existing
spoke to luke dwelling.
There are 2 services Comment Number: 3 Comment Originated: 01/14/2019
Currently. 01/14/2019: Please contact Luke Unruh at 970-416-2724 to discuss power
requirements so I can provide an estimate if needed.
Department: PFA
Contact: Andrew Rosen, 970-416-2599, Uarosen@poudre-fire.org
Topic: General
Comment Number: 1 Comment Originated: 01/09/2019
01/09/2019: FOR INFORMATION
2018 IFC CODE ADOPTION
Poudre Fire Authority and the City of Fort Collins (Town of Timnath, Larimer
County) are in the process of adopting the 2018 International Fire Code. Code
adoption is anticipated in early 2019. Building plan reviews shall be subject to
the adopted version of the fire code in place at the time of plan review submittal
and permit application.
Comment Number: 2 Comment Originated: 01/09/2019
01/09/2019: FOR NEXT ROUND
ACCESS
Fire access is required to within 150' of all exterior portions of any building as
measured by an approved route around the perimeter. Access is typically
measured from the public road but for the purposes of this section, fire access
cannot be measured from an arterial road (Laurel). As such, a dedicated fire
lane will be needed on the property, designed to standard fire lane
specifications outlined in the comment below.
Comment Number: 3 Comment Originated: 01/09/2019
01/09/2019: FOR INFORMATION
FIRE LANE SPECIFICATIONS
If the existing drive on the east side of the property is to be dedicated as a fire
4
lane, the following specifications shall apply, unless otherwise approved by the
fire marshal. A fire lane plan shall be submitted for approval prior to installation.
In addition to the design criteria already contained in relevant standards and
policies, any new fire lane must meet the following general requirements:
> Shall be designated on the plat as an Emergency Access Easement.
> Maintain the required 20 foot minimum unobstructed width & 14 foot minimum
overhead clearance.
> Be designed as a flat, hard, all-weather driving surface capable of supporting
40 tons.
> The required turning radii of a fire apparatus access road shall be a minimum
of 25 feet inside and 50 feet outside.
> Be visible by painting and/or signage, and maintained unobstructed at all
times.
Comment Number: 4 Comment Originated: 01/09/2019
01/09/2019: FOR NEXT ROUND
RESIDENTIAL FIRE SPRINKLER SYSTEM
Duplex residences require an approved residential fire sprinkler system. Please
contact the Building department for further information.
Comment Number: 5 Comment Originated: 01/09/2019
01/09/2019: FOR APPROVAL
ADDRESSING/WAYFINDING
The address shall be clearly visible from the street in no less than 6" tall
numerals on a contrasting background. Each unit will be allocated a unit
identifier such as A or B with clear wayfinding signage indicating the best
access for each.
Comment Number: 6 Comment Originated: 01/09/2019
01/09/2019: FOR APPROVAL
HYDRANT
Spoke to Andrew A fire hydrant is required within 400' of the building as measured along an
All good. approved path of vehicle travel. The hydrant at the NW corner of Laurel and
Loomis meets this distance requirement however it is the applicant's
responsibility to verify the flow. Please contact the water department for
information.
Department: Stormwater Engineering
Contact: Dan Mogen, 970-305-5989, Udmogen@fcgov.com
Topic: General
Comment Number: 2 Comment Originated: 01/04/2019
01/04/2019: INFORMATION ONLY:
No proposed site changes were shown in this submittal; therefore, no
requirements apply at this time. If future submittals include site changes that are
not shown on these plans, please contact Dan Mogen in Water Utilities
Engineering at (970)305-5989 or dmogen@fcgov.com to coordinate and
determine what requirements, if any, will apply.
Department: Water-Wastewater Engineering
Contact: Dan Mogen, 970-305-5989, Udmogen@fcgov.com
Topic: General
5
Comment Number: 1 Comment Originated: 01/04/2019
01/04/2019: No changes proposed; therefore, no requirements. Please
contact me to discuss if any changes are needed to water or sewer services.
Department: Technical Services
Contact: Jeff County, 970-221-6588, Ujcounty@fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 01/14/2019
01/14/2019: FOR APPROVAL:
We have no comments, but will need to see any future submittals.