HomeMy WebLinkAboutMASON PLACE - FDP190005 - SUBMITTAL DOCUMENTS - ROUND 1 - (3)MEETING MINUTES 2/15/19 2882 Wyandot St. Denver, CO 80211 303 433-4094 Project Name: Mason Place Project Number: 17036 Meeting: Building Code Pre-Submittal Meeting 2/14/2018 Location: 281 N. College Ave., Fort Collins Attendees: Housing Catalyst Kristin F Josh S Michele C Nick B Dan G Shopworks Chad H Aleka P Emily A Stacey T Fort Collins Sarah C Tenae B Number Description Resp. Due 1.01 Fort Collins Amendments to 2018 IBC Local amendments are available online. Design team will reference them. Record Only --- 1.02 Demo Permit Process: First obtain a demo permit from the State, then bring this permit to Fort Collins to get a permit from the City. Record Only --- 1.03 Schedule We are scheduled to finish CD’s 5/31/19 and log in for permit on this day. Record Only --- 1.04 Atrium Currently included in design: • NFPA 13 sprinkler system • 1 hour rating on all walls surrounding atrium • Mechanical smoke exhaust system with make up air louvers on ground level • Class A rating on all interior materials in atrium This appears to be acceptable. Record Only --- 1.05 Elevator Shaft 1 hour rating on shaft walls required. 60 minute rating on doors likely required. SWARC to verify and follow up with Fort Collins if there is a different approach. SWARC 3/1 1.06 STC 39 Rating @ Wall Assembly + Windows Required within 1000 ft of train tracks. Site is not within 250 feet of College Ave. It’s possible that rating may only be required on façade facing the tracks with a variance. SWARC and HC will get window cost information from IKota and determine if we would like to pursue a variance. SWARC HC 3/1 1.07 East Wall @ 5’-0” F.S.D. SWARC will site sections of the code used to justify water washing this wall, MEETING MINUTES 2/15/19 2882 Wyandot St. Denver, CO 80211 303 433-4094 1.10 Accessible Entrances Insure accessible thresholds on 60% of entrance doors. (To be provided @ main entry, staff office entry, and courtyard entry.) Record Only --- 1.11 Prescriptive IECC Requirements Because electric heating will be used, building enclosure elements must meet prescriptive IECC requirements. The Team may want to pursue a variance for the exterior rigid wall insulation requirement. SWARC to coordinate with Group14. SWARC Group14 3/1 1.12 Electric Vehicle Ready ¾” min, conduit required at 10% of parking spaces. 28 parking spaces are provided, so conduit will be provided at 3 spaces. SWARC and MV to review requirements in Fort Collins Amendments to insure everything is met. SWARC MV 3/1 End of Minutes and write up a letter for a variance. SWARC 3/1 1.08 Courtyard Egress Doors SWARC and HC will decide if delayed egress is desired on these doors (IBC 10.10.1.9.8), or if they will unlock in the case of a fire alarm. Team to meet with door hardware consultant next Tuesday. SWARC HC 3/1 1.09 Unit Ventilation Mechanical ventilation through PTAC units is required. Therefore, natural ventilation from windows is not a requirement. Record Only ---