Loading...
HomeMy WebLinkAboutFTC ADVANCED AUTO PARTS - BDR190002 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSREVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) B 01-23-19 RPH 90% ZONING FTC ADVANCE AUTOPARTS SC 1023 N. COLLEGE AVE FORT COLLINS, CO 80524 SMALL CELL ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS FROM 3131 SOUTH VAUGHN WAY:HEAD WEST ON S VAUGHN WAY. TURN LEFT ONTO THE I-225/S PARKER RD RAMP. USE THE RIGHT 3 LANES TO TAKE THE INTERSTATE 225 N EXIT. MERGE ONTO I-225 N. USE THE LEFT 3 LANES TO TAKE EXIT 12A TO MERGE ONTO I-70 W TOWARD DENVER. USE THE RIGHT 2 LANES TO TAKE EXIT 279 A FOR I-270 W TOWARD FORT COLLINS/BOULDER. CONTINUE ONTO I-270 W. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARD FT COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W/E MULBERRY ST TOWARD FT COLLINS. MERGE ONTO CO-14 W/E MULBERRY ST. TURN RIGHT ONTO RIVERSIDE AVE. CONTINUE ONTO JEFFERSON ST. TURN RIGHT ONTO N COLLEGE AVE. THE SITE WILL BE ON THE LEFT. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER CONTACT: KENT McDERMOTT KENT.MCDERMOTT@VERIZONWIRELESS.COM AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 12/03/18. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES.ANY WORK ASSOCIATED WITH THE ROOFING MEMBRANE SUCH AS ANCHORAGE, CONDUIT PLACEMENT, ADDED ISOLATION PADS, ETC. MUST BE INSTALLED BY A ROOFER THAT IS APPROVED BY THE MANUFACTURER OF THE INSTALLED ROOF MEMBRANE. 9. FINAL WORK SHALL BE PROPERLY SEALED AND WATERTIGHT. ALL DEBRIS SHALL BE REMOVED FROM THE ROOF AND PHOTOGRAPHIC RECORD OF FINAL CONDITION OF THE ROOF SHALL BE SENT TO THE OWNER'S REPRESENTATIVE. NOTIFICATION OF COMPLETION OF WORK SHALL BE DONE VIA THE AGREED UPON CHANNELS OF COMMUNICATION. 10. RF SIGNAGE TO BE INSTALLED AT ANY/ALL ROOF ACCESS POINTS ON THE BUILDING. GENERAL NOTES GN-1 2 REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) B 01-23-19 RPH 90% ZONING PHOTOSIMULATION VIEWS PH-1 3 1 PH-1 PHOTOSIMULATION VIEW (BEFORE) SCALE: N.T.S. 2 PH-1 PHOTOSIMULATION VIEW (AFTER) SCALE: N.T.S. UT UT UT UT UT U/G U/G U/G U/G U/G U/G U/G U/G W W W UE UE W W W UE UE UE UE UE UE UE UE UE UE UE GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS SD SD SD SD SD SD SD SD SD SD UE UE UE UE UE UE UE UE UE UE SS SS SS SS SS UT UT UT U/G U/G U/G U/G U/G U/G U/G UE UE UE U E UE UE UE UE UE UE UE UE UE OHE OHE OHE OHE OHE X RD RD RD RD 15'-0" 15'-0" N UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 HEMLOCK ST. EXISTING BUILDING PROPOSED 2'-0"X3'-0" FIBER VAULT PROPOSED 10'-0" VERIZON ACCESS & UTILITY EASEMENT PROPOSED VERIZON UTILITY METER MOUNTED TO CMU WALL (PAINT TO MATCH WALL) PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO CMU WALL (PAINT TO MATCH WALL) PROPOSED QUASI-OMNI INSIDE FAUX CHIMNEY CONCEALMENT SHROUD MOUNTED TO NON-PENETRATING SLED MOUNT (TO BE PAINTED GRAY TO MATCH BUILDING) (2) PROPOSED RRH'S, (1) OVP, AND (1) DIPLEXER MOUNTED TO NON-PENETRATING SLED MOUNT U/G U/G U/G U/G U/G U/G UE UE UE UE UE UE UE UE UE UE UE GAS GAS GAS GAS GAS GAS GAS GAS GAS SD SD UE UE UE UE SS SS SS SS SS UT UT UT UT U/G U/G U/G U/G X X RD RD RD RD 15'-0" 15'-0" N UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 OVP DESIGNATION CABLE TABLE ±200' LENGTH 1 NO. TYPE CONDUIT 1/2" COAX ±10' 4 HYBRIFLEX 2x4 LOW INDUCTANCE SIZE WITH 3-CELL PLENUM FIBER IN CONDUIT FIBER RUN ±20' 1 2" MAXCELL INNERDUCT COAX REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 21'-0" 17'-8" 21'-0" 17'-8" 28'-0" 30'-0" 15'-0" 5'-0" PROPOSED VERIZON OMNI ANTENNA RAD CL 28'-0" AGL TOP OF ROOF 17'-8" AGL TOP OF PARAPET 21'-0" AGL PROPOSED QUASI-OMNI ANTENNA MOUNTED TO NON-PENETRATING SLED MOUNT (PAINT GRAY TO MATCH BUILDING) (2) PROPOSED RRH'S, (1) OVP AND (1) DIPLEXER MOUNTED TO NON-PENETRATING SLED MOUNT EXISTING BUILDING REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) B 01-23-19 RPH 90% ZONING 1 Z-3 EXISTING NORTH ELEVATION SCALE: 1/8"=1'-0" 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED QUASI-OMNI ANTENNA MOUNTED TO NON-PENETRATING SLED MOUNT (PAINT GRAY TO MATCH BUILDING) REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) B 01-23-19 RPH 90% ZONING 1 Z-4 LINE OF SIGHT ELEVATION SCALE: N.T.S. LINE OF SIGHT ELEVATION Z-4 7 EXISTING BUILDING NOTE: THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS A VISUAL REPRESENTATION OF HOW THE SITE WOULD APPEAR TO A 5'-8" PERSON STANDING ON THE OPPOSITE SIDE OF N. COLLEGE AVE. 2'-8" 1'-11" 1'-0" 2'-1" 1'-11" 1'-8" CHARLES CUBE SMALL CELL CABINET MODEL: RL11411AN1 CABINET WEIGHT: 82LBS. (AS SHIPPED) 2'-2" 8.27" 2.76" 3.19" 7.28" FRONT VIEW SIDE VIEW 13" 18" 13" TOP VIEW 10" 19.1" 15.7" MOUNTING BRACKET FRONT VIEW SIDE VIEW 10.3" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) B 01-23-19 RPH 90% ZONING 1 Z-5 RRH DETAIL N.T.S. 2 UT UT UT UT UT UT U/G U/G U/G U/G U/G U/G W W UE W W UE UE UE UE UE UE UE GAS GAS GAS GAS GAS UE UE UE UE UE UE UE UE UE UE UE SS SS SS SS SS SS SS SS SS SS SS UT U/G U/G U/G UE UE UE U E UE UE UE UE OHE OHE OHE OHE X RD RD RD RD UT UT UT UT UT U/G U/G U/G U/G U/G U/G W W UE W W UE UE UE UE UE UE UE GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS U E UE UE UE UE UE UE UE UE UE UE SS SS SS UT U/G U/G U/G UE UE UE UE UE UE UE UE OHE OHE OHE OHE X R D RD RD RD REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) B 01-23-19 RPH 90% ZONING 1 Z-6 LANDSCAPING PLAN - EXISTING SCALE: 1/16"=1'-0" 2 Z-6 LANDSCAPING PLAN - PROPOSED SCALE: 1/16"=1'-0" LANDSCAPE PLAN Z-6 9 EXISTING OFF SITE TREES; TO REMAIN (TYP) NOTE: - A PERMIT MUST BE OBTAINED FROM THE CITY FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES BETWEEN THE SIDEWALK AND CURB, MEDIANS AND OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE THE LOCATION AND SPECIES TO BE PLANTED. FAILURE TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF FORT COLLINS CODE SUBJECT TO CITATION (SECTION 27-31) AND MAY ALSO RESULT IN REPLACING OR RELOCATING TREES AND A HOLD ON CERTIFICATE OF OCCUPANCY. - ALL EXISTING TREES TO REMAIN AND BE PROTECTED. - CONTRACTOR IS RESPONSIBLE FOR REPLACING ANY DAMAGED LANDSCAPING DURING CONSTRUCTION NOT OUTLINED IN THIS PLAN TO BE REMOVED. EXISTING PROPERTY LINE EXISTING CURB EXISTING PARKING LOT 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 16 0 8 16 32 64 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 16 0 8 16 32 64 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING BUILDING EXISTING OFF SITE TREES; TO REMAIN (TYP) EXISTING PROPERTY LINE EXISTING CURB EXISTING BUSH; TO BE REMOVED EXISTING BUSHES; TO REMAIN (TYP OF 2) EXISTING PARKING LOT EXISTING BUILDING EXISTING BUSH; TO BE REPLANTED AFTER CONSTRUCTION EXISTING BUSH; TO BE REMOVED EXISTING BUSH; TO BE REPLANTED AFTER CONSTRUCTION Z-5 OVP DETAIL N.T.S. 3 Z-5 CHARLES SMALL CELL CABINET N.T.S. CONSTRUCTION DETAILS Z-5 8 4 Z-3 DIPLEXER DETAIL N.T.S. GRADE 0'-0" AGL 2 Z-3 PROPOSED NORTH ELEVATION SCALE: 1/8"=1'-0" 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS Z-3 6 EXISTING CMU ENCLOSURE TOP OF ROOF 17'-8" AGL TOP OF PARAPET 21'-0" AGL GRADE 0'-0" AGL PROPOSED VERIZON EQUIPMENT CABINET, METER, DISCONNECT AND PANEL MOUNTED TO CMU WALL (PAINT TO MATCH CMU WALL) PROPOSED PERMANENT CAGED ACCESS LADDER (PAINT TO MATCH BUILDING) EXISTING CMU ENCLOSURE EXISTING BUILDING PROPOSED HYBRID CABLE ROUTED ALONG BACK OF PARAPET FROM EQUIPMENT CABINET TO OVP PROPOSED HYBRID CABLE ROUTED UP EXTERIOR WALL IN CONDUIT (PAINT TO MATCH) TOP OF PROPOSED VERIZON ANTENNA 30'-0" AGL PROPOSED LINE OF SIHT FROM A PERSON STANDING ACROSS COLLEGE DRIVE (SEE SHEET Z-4) SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) B 01-23-19 RPH 90% ZONING ENLARGED SITE PLAN Z-2 5 1 Z-2 ENLARGED SITE PLAN SCALE: 1/8"=1'-0" 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 4" PROPOSED 2'-0"X3'-0" FIBER VAULT PROPOSED 10'-0" VERIZON ACCESS & UTILITY EASEMENT PROPOSED VERIZON UTILITY METER MOUNTED TO CMU WALL (PAINT TO MATCH WALL) PROPOSED VERIZON EQUIPMENT CABINET MOUNTED TO CMU WALL (PAINT TO MATCH WALL) PROPOSED QUASI-OMNI INSIDE FAUX CHIMNEY CONCEALMENT SHROUD MOUNTED TO NON-PENETRATING SLED MOUNT (TO BE PAINTED GRAY TO MATCH BUILDING) (1) PROPOSED RRH, (1) OVP, AND (1) DIPLEXER MOUNTED TO NON-PENETRATING SLED MOUNT PROPOSED HYBRID CABLE ROUTED ON SLEEPERS FROM EQUIPMENT CABINET TO OVP EXISTING 75kVA TRANSFORMER EXISTING CMU ENCLOSURE PROPOSED CAGED ACCESS LADDER (PAINT TO MATCH BUILDING) EXISTING BUILDING PROPOSED HYBRID CABLE TRENCHED FROM EQUIPMENT CABINET TO BUILDING PROPOSED HYBRID CABLE ROUTED UP EXTERIOR WALL IN CONDUIT (PAINT TO MATCH BUILDING) EXISTING 8'-0" WIDE UTILITY EASEMENT EXISTING DRAINAGE EASEMENT PROPOSED 3'-0" TRAFFICMAT FROM ROOF ACCESS LOCATION TO PROPOSED EQUIPMENT PROPOSED EME BARRIER (FINAL DESIGN TBD) (TO BE PAINTED GRAY TO MATCH BUILDING) PROPOSED HYBRID CABLE ROUTED IN ROOFTOP CABLE TRAY FROM EQUIPMENT CABINET TO OVP REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0098 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC ADVANCE AUTOPARTS SC SITE ADDRESS: 1023 N. COLLEGE AVE FT. COLLINS, CO 80524 JURISDICTION: CITY OF FT COLLINS A 12-18-18 RPH 80% ZONING SHEET NUMBER: JOSHUA D. ROZINA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #53217 (EXP. 10/31/2019) B 01-23-19 RPH 90% ZONING 1 Z-1 SITE PLAN SCALE: 1"=10'-0" SITE PLAN Z-1 4 LONG LAT SITE COORDINATES 105° 04' 37.57" WEST (NAD 83) 40° 36' 02.69" NORTH (NAD 83) NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ANTENNA(S) EQUIPMENT CABINET, RADIO(S), POWER PANEL ASSOCIATED EQUIPMENT DISCONNECT, METER, FIBER DEMARC BOX UTILITY VOLUME (FT³) 4.27 FT³ 11.66 FT³ 2.41 FT³ DESCRIPTION INCLUDES: EQUIPMENT VOLUME TABLE 14"Ø x 48" H OMNI ANTENNA N COLLEGE AVE. EXISTING SIDEWALK EXISTING 75kVA TRANSFORMER LONG LAT SITE COORDINATES -105.077103 40.600747 PROPOSED HYBRID CABLE TRENCHED FROM EQUIPMENT CABINET TO BUILDING PROPOSED HYBRID CABLE ROUTED UP EXTERIOR WALL IN CONDUIT (PAINT TO MATCH BUILDING) EXISTING GRASS AREA EXISTING PARKING LOT EXISTING 15'-0" WIDE UTILITY EASEMENT EXISTING DRAINAGE EASEMENT EXISTING ACCESS EASEMENT EXISTING DRAINAGE EASEMENT EXISTING 8'-0" WIDE UTILITY EASEMENT PROPOSED 3'-0" TRAFFICMAT FROM ROOF ACCESS LOCATION TO PROPOSED EQUIPMENT PROPOSED CAGED ACCESS LADDER (PAINT TO MATCH BUILDING) B 01-23-19 RPH 90% ZONING LEGEND W W W SS SS SS F F F GAS GAS GAS GAS GAS OE OE UT UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD SD SD SD E E E UE UE UE OT OT OT EV D O O O O U/G U/G OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING SKYLIGHT HVAC UNIT AC SECURITY CAMERA VENT PIPE VP BOLLARD COMM DISH GROUNDING NOTES: 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. 2. ALL GROUNDING DEVICES SHALL BE U.L. APPROVED OR LISTED FOR THEIR INTENDED USE. 3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE. 4. GROUND WIRES SHALL BE #2 AWG BARE SOLID COPPER UNLESS NOTED OTHERWISE. 5. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC ("CADWELDS") TO GROUND RODS, GROUND RING WIRE, AND FENCE POSTS UNLESS NOTED OTHERWISE. CLEAN SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED TO GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZED PAINT. 6. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO-HOLE BRASS MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING SCREW SET.) CLEAN GROUND BAR TO SHINY METAL AFTER MECHANICAL CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING. 7. GROUND CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING KITS. 8. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 8" RADIUS. 9. PRIOR TO INSTALLING LUGS ON GROUND WIRES, APPLY THOMAS & BETTS KOPR-SHIELD (TM OF JET LUBE, INC.) PRIOR TO BOLTING GROUND WIRE LUGS TO GROUND BARS, APPLY KOPR-SHIELD OR EQUAL. 10. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY REMOVING ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING CONNECTION, APPLY APPROPRIATE ANTI-OXIDIZATION PAINT. ELECTRICAL NOTES: 1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. ANY QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTORS FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. 2. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO ROUGH-IN. 3. THE CONDUIT RUNS AS SHOWN ON THE PLANS ARE APPROXIMATE. EXACT LOCATION AND ROUTING SHALL BE PER EXISTING FIELD CONDITIONS. 4. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY NEC. 5. ALL CONDUITS SHALL BE MET WITH BENDS MADE IN ACCORDANCE WITH NEC CHAPTER 9, TABLE #2. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER. 6. ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PLASTIC THROAT INSULATING GROUNDING BUSHINGS. 7. ALL WIRE SHALL BE TYPE THHN/THWN, SOLID, ANNEALED COPPER UP TO SIZE #10 AWG (#8 AND LARGER SHALL BE CONCENTRIC STRANDED) 75° C (167° F), 98% CONDUCTIVITY, MINIMUM #12. 8. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J-BOXES, EQUIPMENT BOXES AND CABINETS WITH APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY, OR APPROVED EQUAL. 9. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL. 10. CONDUIT ROUGH-IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTRACTOR AND COMPLY AS REQUIRED. 11. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN NOT HAND WRITTEN. 12. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL DISCONNECT SWITCHES, STARTERS, AND EQUIPMENT CABINETS. 13. THE CONTRACTOR SHALL PREPARE AS-BUILT DRAWINGS, DOCUMENT ANY AND ALL WIRING AND EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS CONTRACT. SUBMIT AT SUBSTANTIAL COMPLETION. 14. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED LAMICOID NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM (NO EXCEPTIONS.) 15. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) AS ADOPTED BY THE APPLICABLE STATE. 16. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR RISERS THROUGH BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS WITHOUT CONSTRUCTION MANAGER'S APPROVAL. SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE PACKED WITH FIRE RATED MATERIAL WHICH SHALL MAINTAIN THE FIRE RATING OF THE WALL OR STRUCTURE. FILL FOR FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. 17. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND EXISTING) SHALL BE FIELD VERIFIED WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN OF CONDUIT AND WIRE. ALL EQUIPMENT SHALL BE PROPERLY CONNECTED ACCORDING TO THE NAMEPLATE DATA FURNISHED ON THE EQUIPMENT (THE DESIGN OF THESE PLANS ARE BASED UPON BEST AVAILABLE INFORMATION AT THE TIME OF DESIGN AND SOME EQUIPMENT CHARACTERISTICS MAY VARY FROM DESIGN AS SHOWN ON THESE DRAWINGS). LOCATION OF ALL OUTLET, BOXES, ETC., AND THE TYPE OF CONNECTION (PLUG OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR TO ROUGH-IN. CONTACT: RYAN SAGAR MRSAGAR45@GMAIL.COM PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 Z-2 Z-3 PROJECT DESCRIPTION 1. INSTALL NEW VERIZON EQUIPMENT CABINET AT GRADE 2. INSTALL (2) RRHS AND ASSOCIATED EQUIPMENT ON NON-PENETRATING SLED MOUNT. 3. INSTALL NEW FIBER VAULT AND FIBER RUN AT GROUND LEVEL. 4. INSTALL ELECTRICAL EQUIPMENT ON EXTERIOR WALL. 5. INSTALL PROPOSED SMALL CELL ANTENNA ON NON-PENETRATING SLED MOUNT. 6. INSTALL COAX FROM RRHS TO ANTENNA. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS JURISDICTION: CITY OF FORT COLLINS, CO ZONING: SERVICE COMMERCIAL DISTRICT APN: 9702450001 PARCEL SIZE: 0.09 AC ELEVATION: 4,973.0 (NAVD 88) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 21'-0" (TOP OF PARAPET) ANTENNA RAD CL: 24'-0" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: BRANDON KISER 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 PH: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, CO 80301 PH: 720 279-8973 LEGAL DESCRIPTION LOT 1; ADVANCE AUTO PARTS; CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO PH-1 GN-1 VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 GENERAL NOTES PHOTOSIMULATION VIEWS SITE PLAN ELEVATIONS ENLARGED SITE PLAN TITLE SHEET T-1 1 RUSH FAMILY LLC JOHN RUSH 1023 N. COLLEGE AVE FORT COLLINS, CO 80524 PHONE: 303-961-5459 EMAIL: JOHNRUSH1@ME.COM PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION Z-4 LINE OF SIGHT ELEVATION Z-5 CONSTRUCTION DETAILS Z-6 LANDSCAPE PLAN