HomeMy WebLinkAboutFTC ADVANCED AUTO PARTS - BDR190002 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSREVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
B 01-23-19 RPH 90% ZONING
FTC ADVANCE AUTOPARTS SC
1023 N. COLLEGE AVE
FORT COLLINS, CO 80524
SMALL CELL
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
FROM 3131 SOUTH VAUGHN WAY:HEAD WEST ON S VAUGHN WAY. TURN LEFT ONTO THE I-225/S
PARKER RD RAMP. USE THE RIGHT 3 LANES TO TAKE THE INTERSTATE 225 N EXIT. MERGE ONTO
I-225 N. USE THE LEFT 3 LANES TO TAKE EXIT 12A TO MERGE ONTO I-70 W TOWARD DENVER. USE
THE RIGHT 2 LANES TO TAKE EXIT 279 A FOR I-270 W TOWARD FORT COLLINS/BOULDER. CONTINUE
ONTO I-270 W. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARD FT COLLINS. TAKE EXIT 269B TO
MERGE ONTO CO-14 W/E MULBERRY ST TOWARD FT COLLINS. MERGE ONTO CO-14 W/E MULBERRY
ST. TURN RIGHT ONTO RIVERSIDE AVE. CONTINUE ONTO JEFFERSON ST. TURN RIGHT ONTO N
COLLEGE AVE. THE SITE WILL BE ON THE LEFT.
FORT COLLINS, COLORADO
CLIENT
PROPERTY OWNER
CONTACT: KENT McDERMOTT
KENT.MCDERMOTT@VERIZONWIRELESS.COM
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
GENERAL NOTES:
1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN
ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 12/03/18.
2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN
STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE
PROPOSED.
3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE
IS NO HANDICAP ACCESS REQUIRED).
5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER
OR SANITARY SERVICE.
6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF
1988 (NAVD 1988).
7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF
ANY TYPE.
8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR
STORAGE OR ANY SOLID WASTE RECEPTACLES.ANY WORK ASSOCIATED
WITH THE ROOFING MEMBRANE SUCH AS ANCHORAGE, CONDUIT
PLACEMENT, ADDED ISOLATION PADS, ETC. MUST BE INSTALLED BY A
ROOFER THAT IS APPROVED BY THE MANUFACTURER OF THE
INSTALLED ROOF MEMBRANE.
9. FINAL WORK SHALL BE PROPERLY SEALED AND WATERTIGHT. ALL
DEBRIS SHALL BE REMOVED FROM THE ROOF AND PHOTOGRAPHIC
RECORD OF FINAL CONDITION OF THE ROOF SHALL BE SENT TO THE
OWNER'S REPRESENTATIVE. NOTIFICATION OF COMPLETION OF WORK
SHALL BE DONE VIA THE AGREED UPON CHANNELS OF COMMUNICATION.
10. RF SIGNAGE TO BE INSTALLED AT ANY/ALL ROOF ACCESS POINTS ON
THE BUILDING.
GENERAL
NOTES
GN-1
2
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
B 01-23-19 RPH 90% ZONING
PHOTOSIMULATION
VIEWS
PH-1
3
1
PH-1
PHOTOSIMULATION VIEW (BEFORE)
SCALE: N.T.S.
2
PH-1
PHOTOSIMULATION VIEW (AFTER)
SCALE: N.T.S.
UT UT UT UT UT
U/G U/G U/G
U/G U/G U/G U/G U/G
W W W
UE UE
W W W
UE UE UE UE
UE
UE UE UE UE UE UE
GAS GAS
GAS GAS GAS GAS
GAS GAS
GAS GAS
GAS GAS GAS GAS GAS GAS GAS GAS GAS
GAS GAS GAS GAS GAS
SD SD SD SD SD SD SD SD SD SD
UE UE UE UE
UE UE UE
UE
UE UE
SS SS SS SS SS
UT UT
UT
U/G
U/G U/G
U/G
U/G U/G U/G
UE UE UE U
E UE UE UE UE UE UE UE UE UE
OHE OHE OHE OHE OHE
X
RD
RD
RD
RD
15'-0"
15'-0"
N
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
HEMLOCK ST.
EXISTING
BUILDING
PROPOSED 2'-0"X3'-0" FIBER VAULT
PROPOSED 10'-0" VERIZON
ACCESS & UTILITY EASEMENT
PROPOSED VERIZON UTILITY METER
MOUNTED TO CMU WALL
(PAINT TO MATCH WALL)
PROPOSED VERIZON EQUIPMENT
CABINET MOUNTED TO CMU WALL
(PAINT TO MATCH WALL)
PROPOSED QUASI-OMNI INSIDE FAUX
CHIMNEY CONCEALMENT SHROUD MOUNTED
TO NON-PENETRATING SLED MOUNT
(TO BE PAINTED GRAY TO MATCH BUILDING)
(2) PROPOSED RRH'S, (1) OVP, AND (1) DIPLEXER
MOUNTED TO NON-PENETRATING SLED MOUNT
U/G U/G U/G U/G U/G U/G
UE
UE UE UE
UE UE UE UE UE UE UE
GAS GAS
GAS GAS GAS GAS GAS
GAS GAS
SD SD
UE
UE UE UE
SS SS SS SS SS
UT UT UT
UT
U/G
U/G U/G U/G
X
X
RD
RD
RD
RD
15'-0"
15'-0"
N
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
OVP
DESIGNATION
CABLE TABLE
±200'
LENGTH
1
NO. TYPE
CONDUIT
1/2" COAX ±10' 4
HYBRIFLEX
2x4 LOW INDUCTANCE
SIZE
WITH 3-CELL PLENUM
FIBER IN CONDUIT
FIBER RUN ±20' 1 2"
MAXCELL INNERDUCT
COAX
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
21'-0"
17'-8"
21'-0"
17'-8"
28'-0"
30'-0"
15'-0"
5'-0"
PROPOSED VERIZON OMNI ANTENNA RAD CL
28'-0" AGL
TOP OF ROOF
17'-8" AGL
TOP OF PARAPET
21'-0" AGL
PROPOSED QUASI-OMNI ANTENNA MOUNTED
TO NON-PENETRATING SLED MOUNT
(PAINT GRAY TO MATCH BUILDING)
(2) PROPOSED RRH'S, (1) OVP AND (1)
DIPLEXER MOUNTED TO
NON-PENETRATING SLED MOUNT
EXISTING BUILDING
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
B 01-23-19 RPH 90% ZONING
1
Z-3
EXISTING NORTH ELEVATION
SCALE: 1/8"=1'-0"
1/8 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
8 0 4 8 16 32
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROPOSED QUASI-OMNI ANTENNA MOUNTED
TO NON-PENETRATING SLED MOUNT
(PAINT GRAY TO MATCH BUILDING)
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
B 01-23-19 RPH 90% ZONING
1
Z-4
LINE OF SIGHT ELEVATION
SCALE: N.T.S.
LINE OF SIGHT
ELEVATION
Z-4
7
EXISTING BUILDING
NOTE:
THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS
A VISUAL REPRESENTATION OF HOW THE SITE
WOULD APPEAR TO A 5'-8" PERSON STANDING ON
THE OPPOSITE SIDE OF N. COLLEGE AVE.
2'-8"
1'-11"
1'-0"
2'-1"
1'-11"
1'-8"
CHARLES CUBE SMALL CELL CABINET
MODEL: RL11411AN1
CABINET WEIGHT:
82LBS. (AS SHIPPED)
2'-2"
8.27"
2.76"
3.19"
7.28"
FRONT VIEW SIDE VIEW
13"
18"
13"
TOP VIEW
10" 19.1"
15.7"
MOUNTING
BRACKET
FRONT VIEW SIDE VIEW
10.3"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
B 01-23-19 RPH 90% ZONING
1
Z-5
RRH DETAIL
N.T.S.
2
UT
UT UT
UT UT UT
U/G
U/G U/G
U/G U/G U/G
W W
UE
W W
UE
UE UE
UE
UE UE UE
GAS
GAS GAS
GAS
GAS
UE UE
UE UE UE UE
UE
UE
UE UE
UE
SS SS SS
SS SS SS SS SS SS SS SS
UT
U/G
U/G U/G
UE UE UE U
E UE UE UE UE
OHE OHE OHE OHE
X
RD
RD
RD
RD
UT UT UT
UT UT
U/G
U/G U/G
U/G U/G U/G
W W
UE
W W
UE
UE UE
UE
UE UE UE
GAS
GAS GAS
GAS
GAS
GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS
U
E UE
UE UE UE UE
UE
UE
UE UE
UE
SS SS SS
UT
U/G
U/G U/G
UE UE UE UE UE UE UE UE
OHE OHE OHE OHE
X
R
D
RD
RD
RD
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
B 01-23-19 RPH 90% ZONING
1
Z-6
LANDSCAPING PLAN - EXISTING
SCALE: 1/16"=1'-0"
2
Z-6
LANDSCAPING PLAN - PROPOSED
SCALE: 1/16"=1'-0"
LANDSCAPE PLAN
Z-6
9
EXISTING OFF SITE
TREES; TO REMAIN
(TYP)
NOTE:
- A PERMIT MUST BE OBTAINED FROM THE CITY
FORESTER BEFORE ANY TREES OR SHRUBS AS NOTED
ON THIS PLAN ARE PLANTED, PRUNED OR REMOVED IN
THE PUBLIC RIGHT-OF-WAY. THIS INCLUDES ZONES
BETWEEN THE SIDEWALK AND CURB, MEDIANS AND
OTHER CITY PROPERTY. THIS PERMIT SHALL APPROVE
THE LOCATION AND SPECIES TO BE PLANTED. FAILURE
TO OBTAIN THIS PERMIT IS A VIOLATION OF THE CITY OF
FORT COLLINS CODE SUBJECT TO CITATION (SECTION
27-31) AND MAY ALSO RESULT IN REPLACING OR
RELOCATING TREES AND A HOLD ON CERTIFICATE OF
OCCUPANCY.
- ALL EXISTING TREES TO REMAIN AND BE PROTECTED.
- CONTRACTOR IS RESPONSIBLE FOR REPLACING ANY
DAMAGED LANDSCAPING DURING CONSTRUCTION NOT
OUTLINED IN THIS PLAN TO BE REMOVED.
EXISTING PROPERTY
LINE
EXISTING CURB
EXISTING
PARKING
LOT
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
16 0 8 16 32 64
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
16 0 8 16 32 64
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
EXISTING
BUILDING
EXISTING OFF SITE
TREES; TO REMAIN
(TYP)
EXISTING PROPERTY
LINE
EXISTING CURB
EXISTING BUSH;
TO BE REMOVED
EXISTING BUSHES; TO
REMAIN (TYP OF 2)
EXISTING
PARKING
LOT
EXISTING
BUILDING
EXISTING BUSH; TO BE
REPLANTED AFTER
CONSTRUCTION
EXISTING BUSH;
TO BE REMOVED
EXISTING BUSH; TO BE
REPLANTED AFTER
CONSTRUCTION
Z-5
OVP DETAIL
N.T.S.
3
Z-5
CHARLES SMALL CELL CABINET
N.T.S.
CONSTRUCTION
DETAILS
Z-5
8
4
Z-3
DIPLEXER DETAIL
N.T.S.
GRADE
0'-0" AGL
2
Z-3
PROPOSED NORTH ELEVATION
SCALE: 1/8"=1'-0"
1/8 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
8 0 4 8 16 32
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ELEVATIONS
Z-3
6
EXISTING CMU
ENCLOSURE
TOP OF ROOF
17'-8" AGL
TOP OF PARAPET
21'-0" AGL
GRADE
0'-0" AGL
PROPOSED VERIZON EQUIPMENT
CABINET, METER, DISCONNECT AND
PANEL MOUNTED TO CMU WALL
(PAINT TO MATCH CMU WALL)
PROPOSED PERMANENT CAGED
ACCESS LADDER
(PAINT TO MATCH BUILDING)
EXISTING CMU
ENCLOSURE
EXISTING BUILDING
PROPOSED HYBRID CABLE ROUTED
ALONG BACK OF PARAPET FROM
EQUIPMENT CABINET TO OVP
PROPOSED HYBRID CABLE ROUTED UP
EXTERIOR WALL IN CONDUIT
(PAINT TO MATCH)
TOP OF PROPOSED VERIZON ANTENNA
30'-0" AGL
PROPOSED LINE OF SIHT FROM A
PERSON STANDING ACROSS
COLLEGE DRIVE
(SEE SHEET Z-4)
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
B 01-23-19 RPH 90% ZONING
ENLARGED SITE PLAN
Z-2
5
1
Z-2
ENLARGED SITE PLAN
SCALE: 1/8"=1'-0"
1/8 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
8 0 4 8 16 32
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
4"
PROPOSED 2'-0"X3'-0"
FIBER VAULT
PROPOSED 10'-0" VERIZON
ACCESS & UTILITY EASEMENT
PROPOSED VERIZON UTILITY METER
MOUNTED TO CMU WALL
(PAINT TO MATCH WALL)
PROPOSED VERIZON EQUIPMENT
CABINET MOUNTED TO CMU WALL
(PAINT TO MATCH WALL)
PROPOSED QUASI-OMNI INSIDE FAUX
CHIMNEY CONCEALMENT SHROUD MOUNTED
TO NON-PENETRATING SLED MOUNT
(TO BE PAINTED GRAY TO MATCH BUILDING)
(1) PROPOSED RRH, (1) OVP, AND (1) DIPLEXER
MOUNTED TO NON-PENETRATING SLED MOUNT
PROPOSED HYBRID CABLE ROUTED
ON SLEEPERS FROM EQUIPMENT
CABINET TO OVP
EXISTING 75kVA
TRANSFORMER
EXISTING CMU
ENCLOSURE
PROPOSED CAGED ACCESS LADDER
(PAINT TO MATCH BUILDING)
EXISTING
BUILDING
PROPOSED HYBRID CABLE TRENCHED
FROM EQUIPMENT CABINET TO BUILDING
PROPOSED HYBRID CABLE ROUTED UP
EXTERIOR WALL IN CONDUIT
(PAINT TO MATCH BUILDING)
EXISTING 8'-0" WIDE
UTILITY EASEMENT
EXISTING DRAINAGE
EASEMENT
PROPOSED 3'-0" TRAFFICMAT FROM ROOF
ACCESS LOCATION TO PROPOSED EQUIPMENT
PROPOSED EME BARRIER
(FINAL DESIGN TBD)
(TO BE PAINTED GRAY TO MATCH BUILDING)
PROPOSED HYBRID CABLE ROUTED IN
ROOFTOP CABLE TRAY FROM
EQUIPMENT CABINET TO OVP
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0098
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 9
SITE NAME:
FTC ADVANCE
AUTOPARTS SC
SITE ADDRESS:
1023 N. COLLEGE AVE
FT. COLLINS, CO 80524
JURISDICTION:
CITY OF FT COLLINS
A 12-18-18 RPH 80% ZONING
SHEET NUMBER:
JOSHUA D. ROZINA, P.E.
COLORADO PROFESSIONAL ENGINEER
LICENSE #53217 (EXP. 10/31/2019)
B 01-23-19 RPH 90% ZONING
1
Z-1
SITE PLAN
SCALE: 1"=10'-0"
SITE PLAN
Z-1
4
LONG
LAT
SITE COORDINATES
105° 04' 37.57" WEST (NAD 83)
40° 36' 02.69" NORTH (NAD 83)
NOTE:
NO WIRELESS TELECOMMUNICATION FACILITY OR
EQUIPMENT OWNER OR LESSEE OR EMPLOYEE
THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO
EXCLUDE ANY OTHER WIRELESS
TELECOMMUNICATION PROVIDER FROM USING THIS
BUILDING, STRUCTURE OR LOCATION.
1 inch = 10ft.
( IN FEET )
GRAPHIC SCALE
10 0 5 10 20 40
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ANTENNA(S)
EQUIPMENT CABINET,
RADIO(S), POWER PANEL
ASSOCIATED
EQUIPMENT
DISCONNECT, METER,
FIBER DEMARC BOX
UTILITY
VOLUME (FT³)
4.27 FT³
11.66 FT³
2.41 FT³
DESCRIPTION INCLUDES:
EQUIPMENT VOLUME TABLE
14"Ø x 48" H OMNI
ANTENNA
N COLLEGE AVE.
EXISTING SIDEWALK
EXISTING 75kVA TRANSFORMER
LONG
LAT
SITE COORDINATES
-105.077103
40.600747
PROPOSED HYBRID CABLE TRENCHED
FROM EQUIPMENT CABINET TO BUILDING
PROPOSED HYBRID CABLE ROUTED UP
EXTERIOR WALL IN CONDUIT
(PAINT TO MATCH BUILDING)
EXISTING
GRASS AREA
EXISTING
PARKING LOT
EXISTING 15'-0" WIDE UTILITY EASEMENT
EXISTING DRAINAGE EASEMENT
EXISTING ACCESS EASEMENT
EXISTING DRAINAGE EASEMENT
EXISTING 8'-0" WIDE
UTILITY EASEMENT
PROPOSED 3'-0" TRAFFICMAT
FROM ROOF ACCESS LOCATION
TO PROPOSED EQUIPMENT
PROPOSED CAGED ACCESS LADDER
(PAINT TO MATCH BUILDING)
B 01-23-19 RPH 90% ZONING
LEGEND
W W W
SS SS SS
F F F
GAS GAS GAS GAS GAS
OE OE
UT UT
X X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD SD SD SD
E E E
UE UE UE
OT OT OT
EV
D
O O O O
U/G U/G
OHW OHW
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
VERIZON COLOR STANDARDS
GRAY-EXISTING EASEMENT ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
SKYLIGHT HVAC UNIT
AC
SECURITY CAMERA VENT PIPE
VP
BOLLARD COMM DISH
GROUNDING NOTES:
1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC
CODE.
2. ALL GROUNDING DEVICES SHALL BE U.L. APPROVED OR LISTED FOR THEIR
INTENDED USE.
3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE.
4. GROUND WIRES SHALL BE #2 AWG BARE SOLID COPPER UNLESS NOTED
OTHERWISE.
5. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC ("CADWELDS") TO GROUND
RODS, GROUND RING WIRE, AND FENCE POSTS UNLESS NOTED OTHERWISE.
CLEAN SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED
TO GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZED PAINT.
6. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO-HOLE BRASS
MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING
SCREW SET.) CLEAN GROUND BAR TO SHINY METAL AFTER MECHANICAL
CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING.
7. GROUND CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING
KITS.
8. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST
PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 8" RADIUS.
9. PRIOR TO INSTALLING LUGS ON GROUND WIRES, APPLY THOMAS & BETTS
KOPR-SHIELD (TM OF JET LUBE, INC.) PRIOR TO BOLTING GROUND WIRE LUGS TO
GROUND BARS, APPLY KOPR-SHIELD OR EQUAL.
10. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY
REMOVING ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING
CONNECTION, APPLY APPROPRIATE ANTI-OXIDIZATION PAINT.
ELECTRICAL NOTES:
1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. ANY
QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTORS FUNCTIONS, THE
SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING
THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS
BEEN AWARDED.
2. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE
AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO ROUGH-IN.
3. THE CONDUIT RUNS AS SHOWN ON THE PLANS ARE APPROXIMATE. EXACT LOCATION AND ROUTING
SHALL BE PER EXISTING FIELD CONDITIONS.
4. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY NEC.
5. ALL CONDUITS SHALL BE MET WITH BENDS MADE IN ACCORDANCE WITH NEC CHAPTER 9, TABLE #2.
NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM INSIDE
SWEEPS FOR ALL CONDUITS 2" OR LARGER.
6. ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PLASTIC THROAT INSULATING GROUNDING
BUSHINGS.
7. ALL WIRE SHALL BE TYPE THHN/THWN, SOLID, ANNEALED COPPER UP TO SIZE #10 AWG (#8 AND
LARGER SHALL BE CONCENTRIC STRANDED) 75° C (167° F), 98% CONDUCTIVITY, MINIMUM #12.
8. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J-BOXES, EQUIPMENT BOXES AND CABINETS WITH
APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY, OR APPROVED EQUAL.
9. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL.
10. CONDUIT ROUGH-IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID
LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTRACTOR AND COMPLY AS REQUIRED.
11. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN NOT HAND WRITTEN.
12. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND
NEC. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL
BOXES, AND ALL DISCONNECT SWITCHES, STARTERS, AND EQUIPMENT CABINETS.
13. THE CONTRACTOR SHALL PREPARE AS-BUILT DRAWINGS, DOCUMENT ANY AND ALL WIRING AND
EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS CONTRACT. SUBMIT AT
SUBSTANTIAL COMPLETION.
14. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE PROVIDED WITH
ENGRAVED LAMICOID NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS
INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM (NO EXCEPTIONS.)
15. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY WITH AMERICANS
WITH DISABILITIES ACT (ADA) AS ADOPTED BY THE APPLICABLE STATE.
16. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR RISERS THROUGH BUILDING. DO
NOT PENETRATE STRUCTURAL MEMBERS WITHOUT CONSTRUCTION MANAGER'S APPROVAL.
SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE PACKED WITH FIRE
RATED MATERIAL WHICH SHALL MAINTAIN THE FIRE RATING OF THE WALL OR STRUCTURE. FILL FOR
FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. ALL
MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE.
17. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND EXISTING) SHALL BE FIELD VERIFIED
WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN OF CONDUIT
AND WIRE. ALL EQUIPMENT SHALL BE PROPERLY CONNECTED ACCORDING TO THE NAMEPLATE DATA
FURNISHED ON THE EQUIPMENT (THE DESIGN OF THESE PLANS ARE BASED UPON BEST AVAILABLE
INFORMATION AT THE TIME OF DESIGN AND SOME EQUIPMENT CHARACTERISTICS MAY VARY FROM
DESIGN AS SHOWN ON THESE DRAWINGS). LOCATION OF ALL OUTLET, BOXES, ETC., AND THE TYPE
OF CONNECTION (PLUG OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE
PRIOR TO ROUGH-IN.
CONTACT: RYAN SAGAR
MRSAGAR45@GMAIL.COM
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2015 (W/LOCAL AMENDMENTS)
NEC 2017
NFPA-1 (2006)
U - UTILITY
IIB
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1
Z-2
Z-3
PROJECT DESCRIPTION
1. INSTALL NEW VERIZON EQUIPMENT CABINET AT GRADE
2. INSTALL (2) RRHS AND ASSOCIATED EQUIPMENT ON NON-PENETRATING SLED MOUNT.
3. INSTALL NEW FIBER VAULT AND FIBER RUN AT GROUND LEVEL.
4. INSTALL ELECTRICAL EQUIPMENT ON EXTERIOR WALL.
5. INSTALL PROPOSED SMALL CELL ANTENNA ON NON-PENETRATING SLED MOUNT.
6. INSTALL COAX FROM RRHS TO ANTENNA.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
JURISDICTION: CITY OF FORT COLLINS, CO
ZONING: SERVICE COMMERCIAL DISTRICT
APN: 9702450001
PARCEL SIZE: 0.09 AC
ELEVATION: 4,973.0 (NAVD 88)
STRUCTURE TYPE: BUILDING
STRUCTURE HEIGHT: 21'-0" (TOP OF PARAPET)
ANTENNA RAD CL: 24'-0" AGL
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: BRANDON KISER
9656 S. PROSPERITY RD.
WEST JORDAN, UT 84088
PH: 801-260-8700
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, CO 80301
PH: 720 279-8973
LEGAL DESCRIPTION
LOT 1; ADVANCE AUTO PARTS; CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
PH-1
GN-1
VERIZON WIRELESS REAL ESTATE
9656 S. PROSPERITY RD.
WEST JORDAN, UT 84088
CONTACT: BRANDON KISER
PHONE: 801-260-8700
GENERAL NOTES
PHOTOSIMULATION VIEWS
SITE PLAN
ELEVATIONS
ENLARGED SITE PLAN
TITLE SHEET
T-1
1
RUSH FAMILY LLC
JOHN RUSH
1023 N. COLLEGE AVE
FORT COLLINS, CO 80524
PHONE: 303-961-5459
EMAIL: JOHNRUSH1@ME.COM
PLANNING CERTIFICATION
APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF
THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF
___________________________, A.D.,20____.
___________________________
DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES
OWNERSHIP CERTIFICATION
_________________________________
BY _________________________________
STATE OF COLORADO )
) SS.
COUNTY OF LARIMER )
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF
___________________________, A.D.,20____,
BY __________________________.
WITNESS MY HAND AND OFFICIAL SEAL.
MY COMMISSION EXPIRES:_______________________
______________________________
NOTARY PUBLIC
SITE PLAN CERTIFICATION
Z-4 LINE OF SIGHT ELEVATION
Z-5 CONSTRUCTION DETAILS
Z-6 LANDSCAPE PLAN