Loading...
HomeMy WebLinkAboutFTC RAMS CROSSING WTE VERIZON - BDR180027 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC RAMS CROSSING 808 W PROSPECT RD FORT COLLINS, COLORADO 80525 NEW ROOFTOP MACRO ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS FROM SOUTH VAUGHN WAY MERGE ONTO 1-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W, KEEP RIGHT AT THE FORK TO CONTINUE ON I-270W, TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FT. COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W, TURN LEFT ONTO S COLLEGE AVE, TURN RIGHT ONTO W LAKE ST, TURN LEFT ONTO CENTRE AVE , TURN RIGHT ONTO W PROSPECT RD, SITE WILL BE ON YOUR RIGHT. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 ROBIN & CHRISTIAN BACHELET PHONE: 970-566-2586 EMAIL: RBACHELET@MAC.COM VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: KENT McDERMOTT EMAIL: KENT.McDERMOTT@VERIZONWIRELESS.COM AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT ST. UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: GENERAL NOTES GN-1 REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING LEGEND W W SS SS SS F F F GAS GAS GAS GAS GAS OE OE UT UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING PHOTOSIMULATION VIEWS PH-1 2 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING SOUTHEAST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTHEAST) N.T.S. REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING PHOTOSIMULATION VIEWS PH-2 4 2 PH-2 PHOTOSIMULATION VIEW (AFTER, LOOKING NORTH) N.T.S. 1 PH-2 PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTH) N.T.S. E Y GM EM SB 5 THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 Z-1 SITE PLAN SCALE: 1"=30'-0" 1 inch = 30ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING SITE PLAN Z-1 5 PROPOSED VERIZON 8' ANTENNA MOUNTED 3'-0" 3'-0" 3'-0" 14'-6" 1'-1" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING EQUIPMENT PLAN Z-2 6 N SECTOR B VZW ANTENNA AZ= 170° 1 Z-2 SOUTH EQUIPMENT PLAN SCALE: 3/16"=1'-0" 0 1 2 4 8 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 3/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 PROPOSED CABLE TRAY SB E E F F F F F F F F F F F F F F F F F E E E E E E E E E 10'-0" 1'-3" 10" 10'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-3 WEST SIDE EQUIPMENT PLAN SCALE: 1/8"=1'-0" REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING 1/8 inch = 1 ft. ( IN FEET ) 49'-8" 45'-9" 40'-7" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 2 Z-4 PROPOSED NORTH ELEVATION SCALE: 1/16"=1'-0" 1 Z-4 EXISTING NORTH ELEVATION SCALE: 1/16"=1'-0" REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS Z-4 8 49'-8" 39'-8" 43'-8" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 2 Z-5 PROPOSED SOUTH ELEVATION SCALE: 1/16"=1'-0" 1 Z-5 EXISTING SOUTH ELEVATION SCALE: 1/16"=1'-0" REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS (CONTINUED) Z-5 49'-8" 45'-9" 40'-7" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 2 Z-6 PROPOSED WEST ELEVATION SCALE: 1/16"=1'-0" 1 Z-6 EXISTING WEST ELEVATION SCALE: 1/16"=1'-0" REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS (CONTINUED) Z-6 12'-0" ± 10'-0" ± 12'-0" ± 10'-0" ± REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING CONCEALMENT DETAILS Z-7 11 2 0 1 2 4 8 1/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED ANTENNA WITHIN PENTHOUSE PROPOSED PENTHOUSE (PENTHOUSE TO MATCH EXISTING BUILDING BRICK) RF TRANSPARENT MATERIAL SPECIFICATIONS FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES: 1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES. 2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING. 3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL. 4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN MATRIX USED IN THE STRUCTURAL SHAPE. 5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION. 6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN DRAWINGS. 7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS FOLLOWS: 1/2" DIAMETER NUTS 8 FT-LBS TORQUE 5/8" DIAMETER NUTS 16 FT-LBS TORQUE 3/4" DIAMETER NUTS 24 FT-LBS TORQUE FIBERGLASS PANEL NOTES: - FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN. - PANELS TO BE MINIMUM 1/4" THICKNESS. 1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF TRANSPARENT MATERIALS. 2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED APPEARANCE. 3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT. 4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT. 5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS: STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS. 6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE ULTRAVIOLET PROTECTION. 7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN. 8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS. PROPOSED RRH WITHIN PENTHOUSE PROPOSED OVP WITHIN PENTHOUSE 1 Z-7 PENTHOUSE CONCEALMENT DETAILS SCALE: 1/4"=1'-0" NOTE: PROPOSED FRAMING AND ATTACHMENT DETAILS NOT SHOWN FOR CLARITY. 10 PROPOSED VERIZON RAD CENTER 40'-7" AGL TOP OF PROPOSED PENTHOUSE 45'-9" AGL TOP OF EXISTING STRUCTURE 49'-8" AGL GRADE 0'-0" AGL GRADE 0'-0" AGL PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 3 PER SECTOR, SECTOR A & C ONLY) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 1 PER SECTOR) PROPOSED ANTENNA PENTHOUSE SHROUD (SEE SHEET Z-9) (2) PROPOSED, (2) FUTURE RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP PER SECTOR) 9 PROPOSED VERIZON RAD CENTER 39'-8" AGL TOP OF EXISTING STRUCTURE 49'-8" AGL GRADE 0'-0" AGL GRADE 0'-0" AGL TOP OF PROPOSED ANTENNAS 43'-8" AGL PROPOSED OVP MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (TYP OF 1 PER SECTOR) (PAINT TO MATCH, SECTOR B ONLY) (2) PROPOSED, (2) FUTURE RRH(S) MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (TYP PER SECTOR) (PAINT TO MATCH, SECTOR B ONLY) PROPOSED VERIZON 8' ANTENNA MOUNTED TO FACADE OF EXISTING BUILDING (TYP OF 3 PER SECTOR, SECTOR B ONLY, PAINT TO MATCH) PROPOSED COAX CHASE FROM UPPER ROOF LEVEL TO MEZZANINE LEVEL TOP OF EXISTING STRUCTURE 49'-8" AGL PROPOSED VERIZON RAD CENTER 40'-7" AGL TOP OF PROPOSED PENTHOUSE 45'-9" AGL GRADE 0'-0" AGL GRADE 0'-0" AGL PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 3 PER SECTOR, SECTOR A & C ONLY) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 1 PER SECTOR) PROPOSED ANTENNA PENTHOUSE (SEE SHEET Z-9) (2) PROPOSED, (2) FUTURE RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 4 PER SECTOR) GRAPHIC SCALE 4 0 2 4 8 16 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EQUIPMENT PLAN (CONTINUED) Z-3 7 N A SECTOR CABLE TABLE 350 AZIMUTH LENGTH 1 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 6x12 HYBRIFLEX B 170 C 230 COAX HYBRIFLEX 1/2" 6x12 1 1 90' SECTOR A VZW ANTENNA AZ= 350° SECTOR C VZW ANTENNA AZ= 230° PROPOSED CABLE TRAY (TYP) PROPOSED HYBRID RUN FROM EQUIPMENT CABINET TO ROOFTOP OVP'S PROPOSED ELECTRIC TO BE PULLED FROM EXISTING ELECTRICAL ROOM IN BUILDING (LOCATION TBD) PROPOSED 10'X10' LEASE AREA BY VERIZON PROPOSED EQUIPMENT CABINET (TYP OF 2) PROPOSED TRAFFIC PAD (TYP) PROPOSED FIBER IN CONDUIT ACROSS ROOF TO CABLE TRAY PROPOSED VERIZON 8' ANTENNA MOUNTED WITHIN PENTHOUSE (TYP OF 3 PER SECTOR, SECTOR A & C ONLY) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 1 PER SECTOR) (2) PROPOSED, (2) FUTURE RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP PER SECTOR) EXISTING ACCESS HACTH PROPOSED ANTENNA PENTHOUSE (SEE SHEET Z-9) 50' 90' PROPOSED ACCESS HATCH B 170 80' 1 6x12 HYBRIFLEX PROPOSED TRAFFIC PAD NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. PROPOSED HYBRID RUN FROM EQUIPMENT CABINETS TO ROOFTOP OVP'S PROPOSED OVP MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (TYP OF 1 PER SECTOR) (PAINT TO MATCH, SECTOR B ONLY) (2) PROPOSED, (2) FUTURE RRH(S) MOUNTED TO FACADE OF EXISTING BUILDING UNDER THE EAVE (TYP PER SECTOR) (PAINT TO MATCH, SECTOR B ONLY) PROPOSED VERIZON 8' ANTENNA MOUNTED TO FACADE OF EXISTING BUILDING (TYP OF 3 PER SECTOR, SECTOR B ONLY, PAINT TO MATCH) PROPOSED COAX RUN FROM RRH(S) TO ANTENNA(S) PROPOSED COAX CHASE FROM UPPER ROOF LEVEL TO MEZZANINE LEVEL WITHIN PENTHOUSE (TYP OF 3 PER SECTOR, SECTOR A & C ONLY) PROPOSED ELECTRIC TO BE PULLED FROM EXISTING ELECTRICAL ROOM IN BUILDING (LOCATION TBD) PROPOSED ANTENNA PENTHOUSE SHROUD (SEE SHEET Z-8) PROPOSED OVP MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP OF 1 PER SECTOR) PROPOSED CABLE TRAY (TYP) PROPOSED 10'X10' LEASE AREA BY VERIZON PROPOSED EQUIPMENT CABINET (TYP OF 2) PROPOSED FIBER VAULT PROPOSED 10' WIDE UTILITY AND ACCESS EASEMENT PROPOSED EXTERIOR FIBER CONDUIT, PAINTED TO MATCH BUILDING EXTERIOR PROPOSED FIBER RUN (UNDERGROUND TO SIDE OF BUILDING) EXISTING ACCESS HACTH PROPOSED FIBER ACROSS ROOF IN CONDUIT TO CABLE TRAY PROPOSED TRAFFIC PAD (TYP) 2 PH-2 2 PH-1 (2) PROPOSED, (2) FUTURE RRH(S) MOUNTED TO BASE OF ANTENNA MOUNT PIPE (TYP PER SECTOR) ELEC PULL BOX SD SD SD SD SD E E E UE UE UE OT OT OT EV D O O O U/G U/G OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICALET XFMR VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING SKYLIGHT HVAC UNIT AC SECURITY CAMERA VENT PIPE VP BOLLARD COMM DISH 2 GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 07/19/17. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. 18. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 19. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988) 20. THE PROPOSED DEVELEPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 21. THE PROPOSED DEVELEPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 EQUIPMENT PLAN Z-4 ELEVATIONS PROJECT DESCRIPTION 1. INSTALL (1) NEW ANTENNA PENTHOUSE. 2. INSTALL(1) NEW NON-PENETRATING SLED MOUNT WITH CONCEALMENT SCREEN. 2. INSTALL (9) NEW 8' ANTENNAS AND (9) RRHS. 3. INSTALL CABLE TRAYS TO RUN HYBRIFLEX TO PROPOSED EQUIPMENT. 4. INSTALL (2) NEW EQUIPMENT CABINETS. 5. INSTALL (3) NEW OVPS. 6. INSTALL NEW FIBER VAULT AND RUN FIBER THROUGH EXTERIOR CONDUIT TO PROPOSED EQUIPMENT. 7. INSTALL NEW TRAFFIC MATS ON THE ROOF 8. RUN NEW POWER TO PROPOSED EQUIPMENT THROUGH EXISTING ELECTRICAL ROOM. 9. INSTALL NEW COAX CABLES. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: HIGH DENSITY MIXED-USE NEIGHBORHOOD DISTRICT APN: 9714321001 PARCEL SIZE: 62,564 S.F. ELEVATION: 5028.7' (NAVD 88) STRUCTURE TYPE: EXISTING STRUCTURE STRUCTURE HEIGHT: 49'-8"± AGL ANTENNA RAD CENTER: SECTOR A & C: 40'-7"± AGL SECTOR B: 39'-8"± AGL APPLICANT: VERIZON WIRELESS REAL ESTATE APPLICANT CONTACT: BRANDON KISER 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 PH: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV DATE BY DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 11 SITE NAME: FTC RAMS CROSSING SITE ADDRESS: 808 W PROSPECT RD FORT COLLINS, CO 80525 JURISDICTION: CITY OF FORT COLLINS AERO PROJECT # : 097-17-0093 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 A 06-16-17 EGW ZONING B 07-17-17 KRC FINAL ZONING C 01-24-18 GAC REVISED ZONING SHEET NUMBER: D 03-07-18 GAC FINAL ZONING E 11-21-18 GAC REVISED ZONING F 12-10-18 GAC REVISED ZONING G 01-29-19 GAC REVISED ZONING LEGAL DESCRIPTION LOT 1, THE SLAB PROPERTY, COUNTY OF LARIMER, STATE OF COLORADO Z-5 PH-1 PHOTOSIMULATION VIEWS PH-2 PHOTOSIMULATION VIEWS Z-3 EQUIPMENT PLAN (CONTINUED) Z-6 ELEVATIONS (CONTINUED) ELEVATIONS (CONTINUED) Z-8 CONCEALMENT DETAILS PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION GN-1 GENERAL NOTES