Loading...
HomeMy WebLinkAboutSW PROSPECT AND I 25 ROADWAY PROJECT - RP180001 - SUBMITTAL DOCUMENTS - ROUND 3 -Erosion Control Review : Comments & Redlines Project Information Project Name: ______________________________ Project Number: ____________________ Prior Name(s): ______________________________ Prior Number(s): ______________________ Round _____ Date Submitted: _____________ Comment Due Date: _____________ Total Disturbance __________ SF GPS Lat _______________ GPS Long _______________ Sensitive Area _____ Steep Slopes (3H:1V) _____ This review or prior reviews showed this to be well under the threshold for needing erosion control. _____ Project Review Check Sheets & Comments Comments: __________ Staff Dev Review Coordinator ______________ Zoning ______________ Planner ______________ Engineer______________ Water Utilities Reviewer ______________ Developing Party Owner ______________ Owner’s Company ____________ Developer ______________ Developer’s Company ____________ EC Design Engineer ______________ EC Design Firm ______________ Review Information Reviewer: _____________________ Received: _____________ Completed Review: __________ Cursory Review Time (hr.): __________ Full Review (hr.): __________ Phone Correspondence (hr.): __________ Email Correspondence (hr.): __________ Internal Staff Coordination (hr.): __________ Applicant Meeting (hr.): __________ Enter all hours round to the nearest 0.25 (15 min) Northern Engineering responses by: Benjamin Ruch Project Engineer 1 Jesse Schlam From: Development Review Coordinators Sent: Friday, October 19, 2018 4:36 PM To: Development Review Group Subject: Development Review Weekly Project Summary 10.19.2018 Attachments: Street Park - Comments Due; FTC Foxstone - Comments Due; Northfield Filing 1 Expanded PDP180011 Round 2 - COMMENTS DUE; Gulley Duran Single-Family Residence FDP180021 Round 2 - COMMENTS DUE; 1032 W Prospect Extra Occupancy - COMMENTS DUE; SW Prospect & I-25 - COMMENTS DUE ; Long Pond Wireless Telecommunications Facility (Round 2) - COMMENTS DUE; Century Wireless Telecommunications Facility FDP - COMMENTS DUE Development Review Weekly Project Summary Projects Submitted This Week (10/11‐10/17) Project Name Project Number Previous Project Number(s) Planner/Coordinator Status Comments Due Date 1 Street Park BDR180010 CDR170075 Pete Wray / NA Routed 11/06/2018 2 FTC Foxstone PDP180007 Pete Wray / Brandy BH Routed 11/06/2018 3 Northfield Filing 1 Expanded (Round 2) PDP180011 PDR170010, PDP170041 Ted Shepard / Todd Sullivan Routed 11/06/2018 4 Gulley Duran Single Family Residence (Round 2) FDP180021 CDR180012 Kai Kleer / Todd Sullivan Routed / COMMENTS ONLY 10/30/2018 5 1032 W Prospect Extra Occupancy BDR180033 NA Shawna VanZee / Todd Sullivan Routed / COMMENTS ONLY 11/06/2018 6 SW Prospect & I‐25 RP180001 NA Marc Virata / Brandy BH Routed 11/06/2018 7 Long Pond Wireless Telecommunication FDP180016 PDP160018 Clay Frickey / Tenae Beane Routed 10/30/2018 8 Century Wireless Telecommunication FDP180022 PDP170017 2 Upcoming Projects To Be Submitted *Routed Project Information: 1. Street Park – BDR180010 Round: 3 Development Review Coordinator: NA Development Review Planner: Pete Wray PWray@fcgov.com Project Location: Located at 607 9th St Project Description: This is a request a Basic Development Review to develop the existing stormwater detention area for the City Streets Facility into a 5.3 acre neighborhood park. The site will include a recreating field, playground, basketball court, covered picnic shelter and restroom. PDT USE ONLY: S:\CDNS\Planning\Project Submittal Documents\Streets Park ‐ BDR180010\Round 3 2. FTC Foxstone – PDP180007 Round: 2 Development Review Coordinator: Brandy Bethurem Harras BBethuremHarras@fcgov.com Development Review Planner: Pete Wray PWray@fcgov.com Project Location: Located at 1961 Caribou Dr Project Description: This is a request for a Project Development Plan without subdivision plat for an unmanned telecommunications site consisting of (3) antenna arrays on a new self‐supporting tower and associated equipment concealed on the ground. PDT USE ONLY: S:\CDNS\Planning\Project Submittal Documents\FTC Foxstone\PDP\Round 2 3. NORTHFIELD FILING 1 EXPANDED – PDP180011 AT&T Prospect & Lemay MA180073 Missy Nelson 10/17/2018 10/31/2018 Ed Carroll Motors MA180031 Missy Nelson 10/17/2018 10/31/2018 Brownes on Howes MA180074 Arlo Schumann 10/18/2018 11/01/2018 Project Name/Type Planner/Coordinator Tentative Submittal Date Breeze Thru Headquarters (Round 2) Kai Kleer / Todd 10/24/2018 3 Round: 2 Development Review Coordinator: Todd Sullivan tsullivan@fcgov.com Development Review Planner: Ted Shepard tshepard@fcgov.com Project Location: Located at the northwest corner of Suniga and Lemay Avenue (Lindenmeier) Project Description: This is a request for a Project Development Plan to construct a single and multi‐family development on a 55.3 acre site. The project consists of multiple buildings types with a total of 440 dwelling units, and commercial unit(s) of 2,650 sq. ft. Buildings will be between one and three stories. The site is located in the LMN( Low Density Mixed‐Use Neighborhood) zone district. PDT USE ONLY: S:\CDNS\Planning\Project Submittal Documents\Northfield PDP\Northfield Filing 1 Extended\PDP180011\1_Submittal\Round_2\YYYY_MMDD_Submittal_Documents 4. GULLEY DURAN SINGLE‐FAMILY RESIDENCE – FDP180021 Round: 2 THIS HAS BEEN APPROVED FOR A 2 WEEK ROUND OF REVIEW COMMENTS ONLY Development Review Coordinator: Todd Sullivan tsullivan@fcgov.com Development Review Planner: Kai Kleer kkleer@fcgov.com Project Location: Located approximately 1/4 mile north of W Trilby Road and 1/4 mile west of S Shields Street Project Description: This is a combination Project Development Plan and Final Plan request to construct a single‐ family dwelling and barn at parcel #961040006. The site would be accessed from S Shields Street from the existing driveway that runs along the north side of the adjacent greenhouse. The property is within the Urban Estate (UE) zone district and is subject to an Administrative (Type 1) review. PDT USE ONLY: S:\CDNS\Planning\Project Submittal Documents\Gulley Duran Single‐Family Residence\FDP000000\0_Submittal\Round_2\YYYY_MMDD_Submittal_Documents 5. 1032 W PROSPECT ROAD EXTRA OCCUPANCY – BDR180033 Round: 1 COMMENTS ONLY Development Review Coordinator: Todd Sullivan tsullivan@fcgov.com Development Review Planner: Shawna VanZee svanzee@fcgov.com Project Location: Located at the northeast corner of W Prospect Road and S Shields Avenue. Project Description: This is a request for a Basic Development Review to allow for Extra Occupancy for five (5) occupants in a single‐family house at 1032 W Prospect Road. This is located in the High Density Mixed‐Use Neighborhood (HMN) zone district. PDT USE ONLY: S:\CDNS\Planning\Project Submittal Documents\Gulley Duran Single‐Family Residence\FDP000000\0_Submittal\Round_2\YYYY_MMDD_Submittal_Documents 4 6. SW PROSPECT & I‐25– Road Project – RP180001 Round: 1 Development Review Coordinator: Brandy Bethurem Harras bbethuremharras@fcgov.com Development Review Engineer: Marc Virata MVirata@fcgov.com Project Location: Located at SW Prospect & I‐25 / East Half of Section 21, Township 7 North Rage 68 West of the 6th P.M. Project Description: The project is proposing an interim roadway section with an asphalt width of 28 feet, which allows for two 12’ travel lanes with a 2’ asphalt shoulder on either side. This interim cross‐section is proposed to match the existing cross‐section currently located on the site. A drainage swale is designed on the high gradient side that will travel along the roadway and collects at a natural low point in the property, where it is diverted under the roadway to the low gradient side. The low gradient side will tie into existing grade at a 4:1 slope. The project will also include public infrastructure require for future development within the relocation of the SW Frontage Road, which include public water and wastewater. PDT USE ONLY: S:\CDNS\Planning\Project Submittal Documents\SW Prospect & I‐ 25\0_Submittal\Round_1\Submittal_Documents 7. Long Pond Wireless Telecommunications Facility – FDP180016 Round: 3 THIS HAS BEEN APPROVED FOR A 2 WEEK ROUND OF REVIEW Development Review Coordinator: Tenae Beane tbeane@fcgov.com Development Review Engineer: Clay Frickey cfrickey@fcgov.com Project Location: Located at 2008 Turnberry Rd Project Description: This is a request for a Final Plan to construct a wireless telecommunications tower at 2008 Turnberry Rd (parcel 883200502). The proposed facility will house a 45' silo communications tower. The site is located in the Low Density Mixed‐Use Neighborhood (LMN) district. PDT USE ONLY: S:\CDNS\Planning\Project Submittal Documents\Long Pond Wireless Telecommunications Facility and Addition of Permitted Use\FDP\Round 3 8. Century Wireless Telecommunications Facility – FDP180022 Round: 2 THIS HAS BEEN APPROVED FOR A 2 WEEK ROUND OF REVIEW Development Review Coordinator: Tenae Beane tbeane@fcgov.com Development Review Engineer: Clay Frickey cfrickey@fcgov.com Project Location: 620 W Horsetooth Rd Project Description: This is a request for a Final Development Plan to build a 55 foot telecommunications tower disguised as a bell tower and accompanying a 40 foot by 40 foot fenced facility . This site is located in the Low Density Residential (RL) zone district. 5 PDT USE ONLY: S:\CDNS\Planning\Project Submittal Documents\Century Addition of Permitted Use ‐ 620 W Horsetooth WTE\FDP\Round 2 NOTE: For additional rounds of review, please ensure your prior workflow tasks in Accela have been completed Document Download. Paper copies will not be distributed. Digital copies are available for download at the links under the individual project. FOR OUTSIDE AGENCIES: Go to http://citydocs.fcgov.com/ Enter project number in the search bar to find submittal materials. Please allow 1‐2 business days for the records to be updated. The Staff Review Meetings are scheduled for November 7th (unless otherwise noted). The Staff Review Agenda will indicate the time of the meeting. Please provide any comments you may have in Accela by the due date. Please save any redlines to the “Redlines” folder in the Project Submittal Documents file or email directly to the Development Review Coordinator. If you do not have access to the Accela program, please send your comments via email to the Development Review Coordinator for the project. Should you need assistance with entering comments in Accela or have any other questions, please contact the Development Review Coordinator prior to the meeting. If additional submittal documents were requested and are not provided or if there are other issues with the electronic document routing, please notify the Development Review Coordinator as soon as possible. Thanks, Development Review Coordination Tenae Beane / Brandy Bethurem Harras / Todd Sullivan City of Fort Collins Community Development & Neighborhood Services 281 N. College Ave. Fort Collins, CO 80524 970.221.6689 DRCoord@fcgov.com Project Name Project Location Project Description: Applicant Name/Company/Phone #: Proposed Staff Review Meeting Date: Wednesday, November 07, 2018 Proposed Comments Due Date: Tuesday, November 06, 2018 Development Review Engineer: Marc Virata Development Review Coordinator: Brandy Bethurem Harras In the grid below, each department will complete: * ASSIGNED REVIEWER - Enter the name of the department reviewer. * DATE - Enter the date the submittal was reviewed for completeness. * SUBMITTAL STATUS - Select from the drop-down list either Complete, Incomplete, or N/A DEPARTMENT ASSIGNED REVIEWER DATE SUBMITTAL STATUS NOTES/ITEMS MISSING File: Project Planner Building Inspection Development Review Engineering Marc Virata 10/18/2018 Complete Economic Development Environmental Planner Stephanie Blochowiak 10/17/2018 Complete FYI: OK to proceed with this small portion and road project but Ecological Characterization Study (ECS) needed - full ECS including USACE wetlands delineation needed for a larger PUD if that PUD extends south all way to Running Dear NA/Archery Range; area wetlands may be jurisdictional (e.g. federal). Steph B and Molly R met onsite with ecological consultant March 2018. Environmental Services Jonathon Nagel # 10/17/2018 n/a Forestry Molly Roche 10/18/2018 Complete GIS Historic Preservation CFC Light & Power Neighborhood Services Park Planning Pavement Management - Poudre Fire Authority Real Estate Planning Technical Services Jeff County 10/19/2018 Complete Traffic Operations Martina Wilkinson 10/18/2018 Complete Ok to move forward without a TIS. We'll need that for any land use proposal in the future. Transfort Transportation Capital Expansion Transportation Planning Water Conservation Zoning City Water Utilities Eng. (Stormwater) Dan Mogen 10/18/2018 Incomplete Drainage report required. City Erosion Control (SWMP Review) Jesse Schlam 10/18/2018 Complete Materials are acceptable for PDP will need to be received for FDP rounds Floodplain Other Other SW Prospect & I-25 SW Prospect & I-25 Bo Brown, CSURF, 970.492.4503 SUBMITTAL REVIEW FOR COMPLETENESS AND DEPARTMENT ASSIGNMENT FORM The project is proposing an interim roadway section with an asphalt width of 28 feet, which allows for two 12’ travel lanes with a 2’ asphalt shoulder on either side. This interim cross-section is proposed to match the existing cross-section currently located on the site. A drainage swale is designed on the high gradient side that will travel along the roadway and collects at a natural low point in the property, where it is diverted under the roadway to the low gradient side. The low gradient side will tie into existing grade at a 4:1 slope. The project will also include public infrastructure require for future SW Prospect / I-25 Road Project Project Narrative Project Location: The project is located within the East Half of Section 21, Township 7 North, Range 68 West of the 6th P.M. More specifically the project is located on the southwest corner of the intersection of Interstate 25 and E. Prospect Road. The project is located within a 142-acre property currently owned by Colorado State University Research Foundation. The project will consist of relocating a portion of the Southwest Frontage Road currently owned and maintained by the Colorado Department of Transportation (CDOT). Project Process: The relocation of the frontage road is proposed as a Road Project (RP) and is accompanied with a Right- of-Way Dedication Application for the Right-of-Way required to encompass the new roadway alignment. While the Right-of-Way dedication will include the width of a proposed ultimate section, the fees have been calculated to include the Right-of-Way required for the interim section plus 4’ shoulders on both sides for a total width of 36 feet. Project Description: The project is proposing an interim roadway section with an asphalt width of 28 feet, which allows for two 12’ travel lanes with a 2’ asphalt shoulder on either side. This interim cross-section is proposed to match the existing cross-section currently located on the site. A drainage swale is designed on the high gradient side that will travel along the roadway and collects at a natural low point in the property, where it is diverted under the roadway to the low gradient side. The low gradient side will tie into existing grade at a 4:1 slope. The project will also include public infrastructure require for future development within the relocation of the SW Frontage Road, which include public water and wastewater. This Road Project (RP) is proposed to be followed by a Planned Unit Development (PUD) process and a Project Development Plan (PDP) for a portion of the overall PUD area, referred to Phase I hereon. The reason for processing the Road Project prior to the PUD and PDP is to have the realignment of the frontage road constructed prior to the improvements proposed by CDOT to the intersection of E. Prospect Road and Interstate 25. The proposed improvements by CDOT would require a portion of the SW Frontage Road to be relocated to allow for additional width within the CDOT Interstate 25 Corridor. The alignment that CDOT is currently proposing does not meet Larimer County Urban Area Street Standards (LCUASS) minimum radii for any street classification. This would require the realigned frontage road to be removed and replaced per LCUASS minimum standards at the time of the PDP for Phase I. The proposed interim section would remain until Phase I is approved and constructed, at which point, the approved ultimate section would be constructed. Without knowing the exact ultimate section that would be designed and approved, the interim section would result in the least amount of reconstruction and redesign. Along with the interim cross-section, an interim pavement section is proposed and would exclude the top lift of asphalt. This would allow for wearing to occur prior to the construction of the ultimate section, at which point, the entire street section would be constructed with the top lift allowing for the entire roadway to look and feel like a new street. Submittal Documents: The documents that will be submitted with the Road Project include the following items • Project Narrative • Utility Plans • Transportation Development Review Fee Form • Deed of Dedication The project is located within the Boxelder Sanitation District and the ELCO Water District. Plans required for water and sewer improvements will be sent directly to Boxelder and ELCO for their review and approval. We would look to the City to route and coordinate with CDOT for review of this project. With the project only including the relocation of the frontage road, many items required for a Project Development Plan (PDP) are not included for reasons described hereon. A Geotechnical Report has not been provided with Road Project, but a complete pavement design will be required at the time of construction. A Traffic Impact Study has not been provided with the understanding that traffic counts would stay consistent with existing conditions after the completion of the project. The functionality of the roadway would also improve by the new alignment and larger sweeping curves. A Drainage Report has not been included with the understanding that the overall impervious would stay the same with the realignment of this roadway by keeping the existing roadway cross-section. With the project being followed closely by a PUD and PDP application, we have not provided and Ecological Study. Through previous meetings with City Staff, it was discussed that there is currently a high-quality wetland located in the middle of the overall site. It is the overall project’s objective for the entire property to make all enhancements and wetland mitigations in that one location to enhance the existing wetland and make it a feature for the entire project to enjoy and use. Maintenance & Repairs: The standard Maintenance and Repair Agreements are proposed to start at the time the interim roadway section is completed. These agreements would restart at the time the final lift of the ultimate section is constructed for Phase 1 of the PDP to follow the project. It is proposed that after the Maintenance Agreement period of the interim road has expired, the City of Fort Collins would take the maintenance of the proposed frontage road, which would include snow clearing at the priority level of a local roadway. PROSPECT ROAD INTERSTATE 25 PROSPECT ROAD BOXELDER DR. CARRIAGE PKWY KITCHELL WAY SUMMIT VIEW DR. OCTOBER 2018 CONTACT INFORMATION Northern Engineering Services, Inc. Cody Snowdon, PE 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 PLANNER/ LANDSCAPE ARCHITECT I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: PROJECT LOCATION VICINITY MAP NORTH 1"=2000' OWNER DEVELOPER/APPLICANT SITE ENGINEER SURVEYOR PROJECT DATUM: NAVD88 City of Fort Collins benchmark 2-01 Located on the North side of Horsetooth Road on the concrete base of the West gate post to the large gravel pit approx. 1/2 mile East of Ziegler Road. Elevation=4861.39 City of Fort Collins benchmark 29-01 Located on the South side of Prospect Road, East of the intersection of the West frontage road of I-25 and Prospect Road, East of the Colorado Welcome Center, on a concrete headwall to an irrigation pipe. Elevation=4904.41 Basis of Bearings Assuming the North line of the Northeast Quarter of Section 21, T.7N., R.69W., as bearing North 88°38'29" West being a Grid Bearing of the Colorado State Plane Coordinate System, North Zone, North American Datum 1983/92, a distance of 2642.40 feet with all other bearings CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner A. GENERAL NOTES 1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. MODIFIED MINOR COLLECTOR \A1;84' ROW 2% MIN. (4% MAX.) 15' UTILITY EASEMENT 4:1 MAX 4:1 MAX \A1;6' 10' PKWY. 12' CENTER LANE 12' TRAVEL LANE 12' TRAVEL LANE 15' UTILITY EASEMENT 4:1 MAX 4:1 MAX \A1;6' 10' PKWY. 8' BIKE LANE 8' BIKE LANE \A1;84' ROW \A1;12' -EOA \A1;28' ROADWAY 2% MIN. (4% MAX.) \A1;12' -EOA 15' UTILITY EASEMENT 4:1 MAX 4:1 MAX 12' TRAVEL LANE 12' TRAVEL LANE 15' UTILITY EASEMENT 2' ASPHALT SHOULDER 4:1 MAX TEMPORARY FRONTAGE ROAD 2' ASPHALT SHOULDER CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: W W W W W W W W W W W W W W W W W W SS W W W E E E E G G FO FO FO E W W W W W W W W W W W W FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO E OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W W W W W W W o W W W W W W W W W W W W W G G W W W W W W W W W W W W W W FO G G G G G G G G G FO FO FO FO FO FO FO FO FO FO FO FO FO FO E E E E E E OHE OHE OHE OHE OHE OHE OHE OHE W W FO FO FO FO FO W W W W W W W W W W W W W W E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / M SS SS S / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 23+50 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 34+50 STA. 24+27.13 STUB w/ PLUG T.O.P.=4894.93 STA. 24+68.21 12"x8" TEE T.O.P.=4895.30 STA. 33+45.74 12"x8" CROSS T.O.P.=4895.05 STA. 34+05.52 12"x6" SWIVEL TEE T.O.P.=4894.76 STA. 25+11.10 22.5° BEND BEGIN HORZ. DEFL. T.O.P.=4896.96 STA. 32+86.15 END HORZ. DEFL. T.O.P.=4895.35 STA. 29+45.52 12"x6" SWIVEL TEE T.O.P.=4897.10 STA. 26+25.00 12"x6" SWIVEL TEE T.O.P.=4898.69 4903.86 4903.86 4903.35 4902.84 4902.34 4901.83 4901.32 4900.81 4900.30 4899.80 4900.24 4902.15 4904.01 4904.01 4903.96 4903.74 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 34+50 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 4899.31 4898.87 4899.08 4899.57 4900.07 4900.56 4901.05 4901.54 4901.95 4899.43 4899.18 4899.06 4898.94 4898.85 4898.88 4898.96 4899.21 4899.33 4899.45 4899.70 4899.82 4899.94 4900.19 4900.31 4900.43 4900.68 4900.80 4900.93 4901.17 4901.30 4901.42 4901.66 4901.77 4901.85 4901.93 4901.47 4898.57 12" PVC 12" PVC 12" PVC STA. 37+97.6 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 20+50 EXISTING GROUND 12" PVC 12" PVC 12" PVC 12" PVC 12" PVC 12" PVC 12" PVC STA. 10+00.0 8"x12" TEE T.O.P.=4898.97 STA. 10+57.4 1.7° DEFLECTION T.O.P.=4897.13 STA. 11+76.5 45.0° DEFLECTION T.O.P.=4896.96 STA. 11+80.0 45.0° DEFLECTION T.O.P.=4893.45 STA. 11+98.8 45.0° DEFLECTION T.O.P.=4893.45 STA. 12+01.7 45.0° DEFLECTION T.O.P.=4896.43 STA. 16+95.57 12"x12" TEE T.O.P.=4896.31 STA. 16+01.93 12"x6" SWIVEL TEE T.O.P.=4894.46 STA. 15+81.44 90° BEND T.O.P.=4893.36 STA. 15+66.25 22.5° BEND T.O.P.=4892.56 STA. 10+24.46 45° BEND 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 20+50 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 30+50 4903.86 4903.86 4903.35 4902.84 4902.34 4901.83 4900.24 4902.15 4904.01 4904.01 4903.96 4903.74 4903.61 4903.48 4903.23 4903.10 4902.97 4902.72 4902.59 4902.46 4902.21 4902.08 4901.95 4901.70 12" PVC 12" PVC 12" PVC STA. 26+73.5 44.9° DEFLECTION T.O.P.=4898.49 STA. 26+75.8 45.0° DEFLECTION T.O.P.=4896.15 STA. 26+85.8 45.0° DEFLECTION T.O.P.=4896.15 STA. 26+88.1 45.1° DEFLECTION T.O.P.=4898.41 STA. 24+27.13 12" STUB w/ PLUG 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 30+50 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00 41+50 4901.32 4900.81 4900.30 4899.80 4899.31 4898.87 4899.08 4899.57 4900.07 4900.56 4901.05 4901.45 4901.19 4901.07 4900.94 4900.68 4900.56 4900.43 4900.18 4900.05 4899.93 4899.68 4899.55 4899.43 4899.18 4899.06 4898.94 4898.85 4898.88 4898.96 4899.21 4899.33 4899.45 4899.70 4899.82 4899.94 4900.19 4900.31 4900.43 4900.68 4900.80 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 41+50 42+00 43+00 44+00 45+00 46+00 47+00 48+00 49+00 50+00 51+00 52+00 53+00 53+50 4901.54 4901.95 4901.42 4901.66 4901.77 4901.85 4901.93 4901.47 4898.57 12" PVC STA. 43+98.88 <edit>° BEND T.O.P.=4893.45 STA. 42+59.13 END HORZ. DEFL. T.O.P.=4896.31 STA. 42+49.13 12"x6" SWIVEL TEE T.O.P.=4896.37 100.0' DEF. STA. 42+27.34 T.O.P.=4896.37 STA. 43+27.35 T.O.P.=4894.89 (@ 0.4°) 71.5' DEF. STA. 43+27.35 T.O.P.=4894.89 STA. 43+98.88 T.O.P.=4893.45 (@ 0.5°) EXISTING GROUND TOP OF WATER PIPE PROPOSED GROUND PROPOSED GROUND 12" PVC 12" PVC 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 53+50 54+00 55+00 56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00 64+00 65+00 65+50 EXISTING GROUND 12" PVC 12" PVC STA. 56+52.9 0.1° DEFLECTION T.O.P.=4894.06 STA. 62+49.13 12"x6" SWIVEL TEE T.O.P.=4892.64 STA. 57+49.13 12"x6" SWIVEL TEE T.O.P.=4893.83 FUTURE SANITARY LINE B SEE SHEET C2.16-C2.18 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X / 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 65+50 66+00 67+00 68+00 69+00 70+00 71+00 72+00 73+00 74+00 75+00 76+00 77+00 77+50 EXISTING GROUND 12" PVC 12" PVC 12" PVC STA. 69+44.1 0.2° DEFLECTION T.O.P.=4890.98 STA. 75+85.6 0.5° DEFLECTION T.O.P.=4891.97 STA. 77+21.0 12"x2 1 2"TEE T.O.P.=4891.06 STA. 74+35.02 11.25° BEND T.O.P.=4891.74 STA. 72+53.15 90° BEND T.O.P.=4891.46 STA. 67+47.38 12"x6" SWIVEL TEE T.O.P.=4891.45 STA. 71+22.21 BEGIN HORZ. DEFL. T.O.P.=4891.26 STA. 72+34.91 END HORZ. DEFL. T.O.P.=4891.43 X X X X X X SS W W W W W 374.83 LF 12" PVC S09°52'53"E 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 19+00 20+00 21+00 22+00 23+00 24+00 EXISTING GROUND PROPOSED GROUND 4903.91 4902.42 4899.58 4901.74 4904.30 4904.42 4904.12 4900.42 4898.12 EXISTING GROUND PROPOSED GROUND SSMH A5 STA 22+76.97 RIM 4902.6± INV. IN 4891.47 (S) INV. OUT 4891.35 (N) 270.79 LF 12" PVC @ 0.22% SS STUB A4 STA 20+06.18 INV. 4890.75 (S) INV. 4890.75 (N) FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC SANITARY SEWER 12" PVC WATER STA.=21+14.38 TOP=4898.11 E E E E E E E E E 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 40+50 40+00 39+00 38+00 37+00 EXISTING GROUND 139.75 LF 12" PVC @ 0.22% SSMH B10 STA 40+02.67 RIM 4902.0± INV. OUT 4891.20 (S) PROPOSED GROUND SS STUB B9 STA 38+62.92 INV. 4890.89 (N) INV. 4890.89 (S) 4898.18 4901.24 4901.86 4902.01 4902.02 PROPOSED GROUND EXISTING GROUND FUTURE 12" PVC SANITARY SEWER W W W W W W W W W W W FO FO FO FO FO FO FO FO FO FO FO OHE OHE 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 20+50 SSMH A2 STA 12+79.68 RIM 4901.7± INV. IN 4888.75 (E) INV. IN 4888.75 (S) INV. OUT 4888.55 (W) 147.58 LF 12" PVC @ 0.22% 132.10 LF 12" PVC @ 0.22% SSMH A1 STA 11+47.58 RIM 4899.4± INV. IN 4888.26 (E) INV. OUT 4888.06 (NW) EXMH A STA 10+00.00 RIM 4899.0± INV. IN 4887.74 (N) INV. IN 4887.74 (SE) INV. OUT 4887.74 (W) 212.82 LF 12" PVC @ 0.22% 346.96 LF 12" PVC @ 0.22% SSMH A3 STA 14+92.50 RIM 4901.0± INV. IN 4889.42 (S) INV. OUT 4889.22 (N) 166.71 LF 12" PVC @ 0.22% SSMH A4 STA 18+39.46 RIM 4900.4± INV. IN 4890.38 (S) INV. OUT 4890.18 (N) 12" PVC WATER STA.=12+69.68 TOP=4896.28 EXISTING GROUND SS STUB A4 STA 20+06.18 INV. 4890.75 (S) INV. 4890.75 (N) EXISTING GROUND 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 20+50 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 292.79 LF 12" PVC @ 0.22% 292.79 LF 12" PVC @ 0.22% 277.31 LF 12" PVC @ 0.25% SSMH A9 STA 31+39.86 RIM 4897.0± INV. OUT 4893.85 (N) SSMH A8 STA 28+47.07 RIM 4898.6± INV. IN 4893.20 (S) INV. OUT 4893.00 (N) SSMH A7 STA 25+54.28 RIM 4899.9± INV. IN 4892.36 (S) INV. OUT 4892.16 (N) SSMH A5 STA 22+76.97 RIM 4902.6± INV. IN 4891.47 (S) INV. OUT 4891.35 (N) 12" PVC WATER STA.=21+14.38 TOP=4898.11 EXISTING GROUND PROPOSED GROUND 270.79 LF 12" PVC @ 0.22% 4901.74 4903.91 4904.30 4904.42 4904.12 4902.42 4900.42 4898.12 EXISTING GROUND PROPOSED GROUND 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 19+50 SSMH A2 STA 10+00.00 RIM 4901.7± INV. IN 4888.75 (E) INV. IN 4888.75 (S) INV. OUT 4888.55 (W) 338.59 LF 12" PVC @ 0.22% 186.94 LF 12" PVC @ 0.22% SSMH A2-1 STA 13+38.59 RIM 4902.0± INV. IN 4889.70 (S) INV. OUT 4889.50 (W) 362.67 LF 12" PVC @ 0.22% SSMH A2-2 STA 15+25.53 RIM 4901.8± INV. IN 4890.31 (S) INV. OUT 4890.11 (N) SSMH A2-3 STA 18+88.20 RIM 4901.0± INV. IN 4891.31 (S) INV. OUT 4891.11 (N) EXISTING GROUND EXISTING GROUND E E E E E E E E E FO FO FO FO FO FO 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 19+50 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 28+50 213.98 LF 12" PVC @ 0.22% 191.46 LF 12" PVC @ 0.22% 220.14 LF 12" PVC @ 0.22% SSMH A2-5 STA 22+93.64 RIM 4899.4± INV. IN 4892.60 (S) INV. OUT 4892.40 (N) SSMH A2-4 STA 21+02.18 RIM 4901.0± INV. IN 4891.98 (S) INV. OUT 4891.78 (N) 162.32 LF 12" PVC @ 0.22% SSMH A2-6 STA 25+13.78 RIM 4898.1± INV. IN 4893.28 (S) INV. OUT 4893.08 (N) 57.82 LF 12" PVC @ 0.22% SS STUB A2-9 STA 27+91.74 RIM 4895.2± INV. IN 4894.09 (S) INV. OUT 4894.09 (N) SSMH A2-8 STA 27+33.92 RIM 4900.9± INV. IN 4893.97 (S) INV. OUT 4893.77 (N) 12" PVC WATER STA.=27+23.78 TOP=4892.22 EXISTING GROUND PROPOSED GROUND 18" MIN. SS STUB A2-7 STA 26+76.10 INV. 4893.64 (S) INV. 4893.64 (N) 4875 4880 4885 4890 4895 4900 4905 4910 4915 4875 4880 4885 4890 4895 4900 4905 4910 4915 20+50 20+00 19+00 18+00 17+00 16+00 15+00 14+00 13+00 12+00 11+00 10+00 9+50 SSMH B STA 10+00.00 RIM 4902.4± INV. IN 4881.50 (E) INV. IN 4883.00 (N) INV. OUT 4881.50 (W) 400.00 LF 12" PVC @ 0.22% 138.41 LF 12" PVC @ 0.22% SSMH B1 STA 11+38.41 RIM 4896.3± INV. IN 4883.50 (N) INV. OUT 4883.30 (S) 400.00 LF 12" PVC @ 0.22% SSMH B2 STA 15+38.41 RIM 4897.0± INV. IN 4884.58 (N) INV. OUT 4884.38 (S) SSMH B3 STA 19+38.41 RIM 4897.8± INV. IN 4885.66 (N) INV. OUT 4885.46 (S) EXISTING GROUND APPROXIMATE DEPTH EXISTING 30" INVERT = 15' EXISTING GROUND W W W W W W W W W W W W W W W W W 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 31+50 31+00 30+00 29+00 28+00 27+00 26+00 25+00 24+00 23+00 22+00 21+00 20+50 400.00 LF 12" PVC @ 0.22% 400.00 LF 12" PVC @ 0.22% 297.21 LF 12" PVC @ 0.22% SSMH B5 STA 27+38.41 RIM 4899.7± INV. IN 4887.82 (N) INV. OUT 4887.62 (S) SSMH B6 STA 30+35.62 RIM 4900.0± INV. IN 4888.67 (N) INV. OUT 4888.47 (S) SSMH B4 STA 23+38.41 RIM 4899.0± INV. IN 4886.74 (N) INV. OUT 4886.54 (S) EXISTING GROUND EXISTING GROUND W W W W W W W W W W W W W W W W W W W W W W W W W W 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 40+50 40+00 39+00 38+00 37+00 36+00 35+00 34+00 33+00 32+00 31+50 247.11 LF 12" PVC @ 0.22% 400.00 LF 12" PVC @ 0.22% SSMH B7 STA 34+35.62 RIM 4900.0± INV. IN 4889.75 (N) INV. OUT 4889.55 (S) SSMH B8 STA 36+82.73 RIM 4899.6± INV. IN 4890.49 (N) INV. OUT 4890.30 (S) EXISTING GROUND 139.75 LF 12" PVC @ 0.22% SSMH B10 STA 40+02.67 RIM 4902.0± INV. OUT 4891.20 (S) PROPOSED GROUND 180.19 LF 12" PVC @ 0.22% SS STUB B9 STA 38+62.92 INV. 4890.89 (N) INV. 4890.89 (S) 4898.18 4901.24 4901.86 4902.01 4902.02 EXISTING GROUND PROPOSED GROUND W W W W W W W W 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) E E E E E E E E E E FO FO FO FO ST W FO FO FO FO FO FO E E E E ST ST / / / / / / / / / / / / / / / / X X X X X X / / / / / / / / / / / / / / / / M / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SW FRONTAGE ROAD SANITARY LINE A SEE SHEET C2.10 84' ROW (BY SEPARATE DOCUMENT REC. NO. ___________ ____) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 4885 4890 4895 4900 4905 4910 4915 4920 4925 4885 4890 4895 4900 4905 4910 4915 4920 4925 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+50 4903.13 4903.63 4904.13 4904.63 4905.08 4904.82 4904.12 4903.42 4903.26 4903.38 4903.51 4903.76 4903.88 4904.01 4904.26 4904.38 4904.51 4904.76 4904.88 4905.00 4905.10 4905.06 4904.97 4904.65 4904.47 4904.30 4903.95 4903.77 4903.60 4903.25 0.50% -0.70% PVI STA = 10+00.00 PVI ELEV = 4903.13 135.0' VC HP ELEV = 4905.10 HP STA = 14+21.30 PVI STA = 14+32.55 PVI ELEV = 4905.30 BVCS: 13+65.05 BVCE: 4904.96 4885 4890 4895 4900 4905 4910 4915 4920 4925 4885 4890 4895 4900 4905 4910 4915 4920 4925 17+50 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+50 4902.72 4902.02 4901.32 4900.62 4899.92 4899.24 4899.21 4899.71 4902.90 4902.55 4902.37 4902.20 4901.85 4901.67 4901.50 4901.15 4900.97 4900.80 4900.45 4900.27 4900.10 4899.75 4899.57 4899.40 4899.14 4899.10 4899.12 4899.33 4899.46 4899.58 4899.83 -0.70% 0.50% 120.0' VC LP ELEV = 4899.10 LP STA = 23+53.07 PVI STA = 23+43.07 PVI ELEV = 4898.92 BCVS: 22+83.07 BVCE: 4899.34 ECVS: 24+03.07 4885 4890 4895 4900 4905 4910 4915 4920 4925 4885 4890 4895 4900 4905 4910 4915 4920 4925 25+50 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 33+50 4900.08 4900.21 4900.33 4900.46 4900.58 4900.71 4900.83 4900.96 4901.08 4901.21 4901.33 4901.46 4901.58 4901.71 4901.83 4901.95 4902.03 4902.06 4902.03 4901.96 4901.84 4901.71 4901.59 4901.46 4901.34 4901.21 4901.09 4900.96 4900.84 0.50% -0.50% PVI STA = 32+92.76 PVI ELEV = 4900.75 120.0' VC HP ELEV = 4902.06 HP STA = 30+00.31 PVI STA = 30+00.31 PVI ELEV = 4902.21 BVCS: 29+40.31 BVCE: 4901.91 EVCS: 30+60.31 ELCO WATER DISTRICT DETAIL: DRAWN: DATE: 1/4 O.D. 4" MIN. TRENCH BACKFILL UNDISTURBED SOIL 3/4" WASHED ROCK COMPACTED PIPE SUBGRADE CLASS B BEDDING DETAIL PIPE O.D. PIPE SUBGRADE UNDISTURBED SOIL 1/4 O.D. 4" MIN. DO NOT USE MECHANICAL EQUIPMENT IN THIS ZONE CAREFULLY COMPACTED SELECT SOIL MODIFIED CLASS B BEDDING DETAIL CLASS B BEDDING DETAIL RKB 10/91 12" MIN. CAREFULLY COMPACTED SELECT SOIL DO NOT USE MECHANICAL EQUIPMENT IN THIS ZONE REQD WITH RCP, VCP, CIP & DIP 3/4" WASHED ROCK COMPACTED REQD WITH PVC, RPM, STL & CMP 12" MIN. TRENCH BACKFILL REVISED: 5/6/94 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C5.01 UTILITY DETAILS No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C5.02 DRAINAGE DETAILS No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C5.03 SITE DETAILS / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ST / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C6.01 EROSION CONTROL DETAILS B. Ruch M. Kuehnel N/A 35 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 9,028 1,504.7 FCMaps This map is a user generated static output from the City of Fort Collins FCMaps Internet mapping site and is for reference only. Data layers that appear on this map may or may not be accurate, current, or otherwise reliable. City of Fort Collins - GIS 1,143.0 1: WGS_1984_Web_Mercator_Auxiliary_Sphere 0 571.50 1,143.0 Feet Notes Legend 6,859 Parcels Growth Management Area Parks Schools Natural Areas City Limits 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 VEHICLE TRACKING CONTROL PAD SHALL BE LOCATED AT EVERY ACCESS POINT TO THE CONSTRUCTION SITE. A SIGN SHALL BE PLACED NEXT TO THE VEHICLE TRACKING CONTROL PAD TO DESIGNATE THE LOCATION AS THE CONSTRUCTION ENTRANCE/EXIT. VEHICLE TRACKING CONTROL PADS SHALL CONSIST OF HARD, DENSE, DURABLE STONE, ANGULAR IN SHAPE AND RESISTANT TO WEATHERING. ROUNDED STONE (i.e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x4'S, PIPES, DIRT, GRAVEL OR ASPHALT, SHALL BE PLACED IN GUTTER TO FACILITATE MOUNTING CURB; HOWEVER, CURB MAY BE CUT DOWN TO A HEIGHT OF 2" OR HIGHER FOR EASIER ACCESS AND REPLACED AT PROJECT COMPLETION. OTHER ACCESS DEVICES MAY BE USED AS ACCEPTED BY THE CITY. CURB CUT 50' MIN. 2" MIN. 6" MIN. 6" MIN. ALTHOUGH NOT NORMALLY USED, THE CITY RESERVES THE RIGHT TO REQUIRE VEHICLE TRACKING CONTROL WITH A TEMPORARY CATTLE GUARD AND/OR WHEEL WASH FACILITIES AT SITES WHERE TRACKING ONTO PAVED AREAS BECOMES A SIGNIFICANT PROBLEM AS DETERMINED BY THE CITY INSPECTOR. IF VEHICLE TRACKING CONTROL WITH WHEEL WASH FACILITIES ARE REQUIRED, ALL WHEELS ON EVERY VEHICLE LEAVING THE SITE SHALL BE CLEANED OF MUD USING A PRESSURE-WASHER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A WATER SOURCE AND CONSTRUCTING A WASHWATER SEDIMENT TRAP. 5. 6. IF VEHICLE WHEEL WASH FACILITIES ARE REQUIRED, CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL AND WHEEL WASH FACILITIES DAILY. ACCUMULATED SEDIMENTS SHALL BE REMOVED FROM THE PAD SURFACE. ACCUMULATED SEDIMENT IN THE WASHWATER/SEDIMENT TRAP SHALL BE REMOVED WHEN THE SEDIMENT REACHES AN AVERAGE DEPTH OF 12-INCHES. 4. 5. VTC NOT TO SCALE CONCRETE WASHOUT AREA VEHICLE TRACKING CONTROL PAD SILT FENCE/PERIMETER PROTECTION COMPACTED BACKFILL FLOW SILT TRENCH FENCE AND FABRIC ATTACHED (ASTM TO D6461) POST. ANCHORED IN 24" MIN 6' MAX FLOW TRENCH AND ATTACHED TO POST. 4"x4" TRENCH SILT FENCE FABRIC (ASTM D6461) ANCHORED IN 18" MIN 24" MIN 42" MIN POSTS PREASSEMBLED SILT FENCE JOIN FIRST ROTATE SECOND POSTS SHALL OVERLAP AT JOINTS SO THAT NO GAPS EXIST IN SILT FENCE. NOTE: THICKNESS OF GEOTEXTILE POST SHALL BE JOINED AS SHOWN, THEN HAS BEEN EXAGGERATED. ROTATED 180° IN DIRECTION SHOWN AND DRIVEN INTO THE GROUND. SILT FENCE JOINTS DRIVE POSTS VERTICALLY INTO THE GROUND TO A MINIMUM DEPTH OF 18". EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 4" DEEP ALONG THE LINE OF POSTS AND UPSLOPE FROM THE BARRIER. ANCHOR TRENCH SHALL BE EXCAVATED BY HAND, WITH TRENCHER, OR WITH SILT FENCE INSTALLATION MACHINE. NO ROAD GRADERS, BACKHOES, ETC. SHALL BE USED. NOT LESS THAN THE BOTTOM 1' OF THE SILT FENCE FABRIC SHALL BE BURIED IN THE TRENCH. THE TRENCH SHALL BE COMPACTED BY HAND, WITH "JUMPING JACK" OR BY WHEEL ROLLING. COMPACTION SHALL BE SUCH THAT THE SILT FENCE RESISTS BEING PULLED OUT OF ANCHOR TRENCH BY HAND. SILT FENCE INDICATED IN THE PLANS SHALL BE INSTALLED PRIOR TO ANY LAND-DISTURBING ACTIVITIES. USE WOOD POSTS OR OTHER MATERIAL AS ACCEPTED BY THE CITY. INSTALLATION NOTES: 1. 2. 3. 4. 5. 6. 7. THE CONTRACTOR SHALL INSPECT SILT FENCE EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT UPSTREAM SEDIMENT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM SEDIMENT REACHES A DEPTH OF 6". SILT FENCE SHALL BE REMOVED WHEN THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. IF ANY DISTURBED AREA EXISTS AFTER REMOVAL, IT SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. MAINTENANCE NOTES: 1. 2. 3. 4" MIN. 4" MIN. 1 1 2" x 1 1 2" WOODEN FENCE POSTS COMPACTED BACKFILL SF SF NOT TO SCALE SWALE WATTEL DIKE SOIL RIPRAP INSTALLATION NOTES 1. CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. 2. VEHICLE TRACKING CONTROL IS REQUIRED IF ACCESS TO CONCRETE WASHOUT AREA IS OFF PAVEMENT. 3. SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. 4. THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. 5. THE CONCRETE WASHOUT SHOULD BE EMPTIED WHEN HALF OF TOTAL HOLDING CAPACITY HAS BEEN REACHED. 6. AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT AN ACCEPTED WASTE SITE. 7. WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. 8. LOCATION OF CONCRETE WASHOUT AREA IS CONCEPTUAL ONLY. FINAL LOCATION TO BE DETERMINED IN THE FIELD AT CONTRACTOR'S DISCRETION. 3H:1V OR FLATTER SIDE SLOPES 12" MIN 8'x 8' MIN OR AS REQUIRED TO CONTAIN WASTE CONCRETE 12" 2'-0" MIN. COMPACTED EMBANKMENT MATERIAL, TYP. BERM AROUND PERIMETER GROUND SURFACE SIGN TO INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA CWA *IMPERMEABLE LINER MAY BE NEEDED IF GROUND WATER IS ENCOUNTERED. TYPE H TYPE M TABLE I CLASSIFICATION AND GRADATION OF ORDINARY RIPRAP RIPRAP DESIGNATION % SMALLER THAN GIVEN SIZE BY WEIGHT INTERMEDIATE ROCK DIMENSIONS (INCHES) d 50 (INCHES)* TYPE VH 50 * d = MEAN PARTICAL SIZE (INTERMEDIATE DIMENSION) BY WEIGHT. 35-50 2-10 50-70 70-100 12 4 18 21 12 24 18 50-70 24 35-50 2-10 50-70 2-10 70-100 35-50 24 9 33 6 42 18 70-100 30 TABLE II GRADATION FOR GRANULAR BEDDING U.S. STANDARD TYPE I CDOT SECT. 703.01 TYPE II CDOT SECT. 703.09 CLASS A SIEVE SIZE 3 INCHES 1 1/2 INCHES 3/4 INCHES 3/8 INCHES #4 #16 #50 #100 #200 PERCENT WEIGHT BY PASSING SQUARE-MESH SIEVES -- -- -- 100 95-100 45-80 10-30 2-10 0-2 90-100 -- 20-90 -- 0-20 -- -- -- 0-3 M (d = 12 IN.) H (d = 18 IN.) VH (d = 24 TABLE III THICKNESS REQUIREMENTS FOR GRANULAR BEDDING U.S. STANDARD SIEVE SIZE FINE-TYPE GRAINED I PERCENT TYPE SOILS* WEIGHT II BY PASSING SQUARE-MESH SIEVES COURSE-GRAINED SOILS** 4 6 6 6 8 8 50 50 50 TYPE II \A1;2'\\A1;SEE TABLE A1;50 2*d III \A1;SEE TABLE III STABILIZATION TOPSOIL FLARED END SECTION (TYP.) GRANULAR BEDDING STABILIZATION TOPSOIL TYPE II BEDDING TYPE I BEDDING GRANULAR BEDDING CONCRETE CUTOFF WALL SOIL RIPRAP AT PIPE OUTLET {WITH CUTOFF WALL} SOIL RIPRAP AT PIPE OUTLET {WITHOUT CUTOFF WALL} * MAY SUBSTITUTE ONE 12-INCH LAYER OF TYPE II BEDDING. THE SUBSTITUTE OF ONE LAYER OF TYPE II BEDDING SHALL NOT BE PERMITTED AT DROP STRUCTURES. THE USE OF A COMBINATION OF FILTER FABRIC AND TYPE II BEDDING AT DROP STRUCTURES IS ACCEPTABLE. ** FIFTY PERCENT OR MORE BY WEIGHT RETAINED ON THE #40 SIEVE. \A1;12" MIN. COMPACT BACKFILL TO 95% STANDARD PROCTOR STAPLES FABRIC SOIL STAPLES FABRIC STABILIZATION TOPSOIL {\LFILTER FABRIC PLACEMENT AND LAP DETAIL} {\LLAP DETAIL} MIX UNIFORMLY 65% FINISHED ORDINARY RIPRAP WITH 35% STABILIZATION TOPSOIL GRADE PRIOR TO PLACEMENT. STABILIZATION (PER TOPSOIL SHALL BE APPROVED CIVIL BY THE LANDSCAPE ARCHITECT. GRADING PLACE STONE-SOIL MIX TO RESULT IN SECURELY PLANS) INTERLOCKED ROCK AT THE DESIGN THICKNESS AND GRADE. PLACE TWO LIFTS (MINIMUM) WITH LARGER ROCK ON TOP. ROCK VOIDS TO BE COMPLETELY FILLED TO FORM A HOMOGENEOUS MASS FOR THE FORMATION OF A ROOT MAT INTERTWINED WITH THE RIPRAP. STABILIZATION SOIL IS TO FILL RIPRAP VOIDS, NOT DISPLACE RIPRAP. COMPACT AND LEVEL TO ELIMINATE ALL VOIDS AND ROCKS PROJECTING ABOVE DESIGN RIPRAP TOP GRADE. DESIGN RIPRAP GRADE PLACEMENT OF ROCK IN TOP LAYER WILL REQUIRE DISTURBANCE OF FIRST LAYER SOIL IS NOT TO BE PERCHED. STABILIZATION SOIL FILLS ALL VOIDS FROM FINISHED SURFACE TO SUBGRADE. \A1;D50% D MAXIMUM THICKNESS OF FIRST LIFT PLACEMENT OF TOP LIFT WILL \A1;D REQUIRE ADJUSTMENT OF FIRST LIFT 4" MIN 6" MAX 5" TYP MEASUREMENT ON SLOPE PERPENDICULAR TO SLOPE SEE TABLES II AND III BELOW. 1.GENERAL PLACEMENT TECHNIQUES SHOULD RESULT IN LARGER ROCK AT THE SURFACE WITH ROCK SECURELY INTERLOCKED AT THE DESIGN THICKNESS AND GRADE. COMPACTION AND LEVELING SHOULD RESULT IN MINIMAL VOIDS AND PROJECTIONS ABOVE GRADE. 2.FINAL SOIL RIPRAP TO BE COMPACTED BY FULL LOADING OF BACKHOE BUCKET. ANY SOFT, YIELDING OR PACKETS OF SMALL ROCK SHALL BE REWORKED. PLACE STABILIZATION TOPSOIL 4 TO 6 INCHES THICK OVER ROCK. NO MORE THAN 25 PERCENT OF ORDINARY RIPRAP ROCK SHALL REMAIN EXPOSED. COORDINATE ROCK PLACEMENT TO PROVIDE TREE OR SHRUB PLANTING PITS AS INDICATED ON LANDSCAPE PLANS, AS APPLICABLE. COORDINATE SCOPE OF WORK AND RESPONSIBILITIES WITH OWNER AND LANDSCAPE CONTRACTOR. 3.PROVIDE CRIMP OR TACKIFY MULCH, HYDROMULCH, AND OR TURF REINFORCEMENT MAT (TRM) / EROSION CONTROL BLANKET ALONG WITH PLANTING, PER APPROVED LANDSCAPE PLANS, TO ENSURE VEGETATION BECOMES ESTABLISHED AND SEED DOES NOT WASH AWAY. 4.PREPARE COMPACTED SUBGRADE PER GEOTECHNICAL ENGINEERING RECOMMENDATIONS, OR PLACE ON UNDISTURBED SUBGRADE. 5.TURF REINFORCEMENT MAT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS FOLLOWING PLACEMENT OF TOPSOIL AND SEEDING. {\LTYPICAL SOIL RIPRAP PLACEMENT} FILTER FABRIC MAY BE USED IN COMBINATION WITH TYPE II BEDDING AT DROP STRUCTURES AS AN ALTERNATIVE TO A TWO LAYER FILTER. FILTER FABRIC SHALL CONFORM TO CDOT SPECIFICATIONS FOR CHANNEL APPLICATIONS REFER TO THE MAJOR DRAINAGE CHAPTER OF THE URBAN STORM DRAINAGE CRITERIA MANUAL, VOLUME 1, FOR RIPRAP SIZING. FOR CULVERT/STORM SEWER OUTLET APPLICATIONS REFER TO THE HYDRAULIC STRUCTURES CHAPTER OF THE URBAN STORM DRAINAGE CRITERIA MANUAL, VOLUME 2, FOR RIPRAP SIZE, RIPRAP DEPTH, BASIN LENGTH, AND BASIN WIDTH. COORDINATE THE COLOR OF ALL EXPOSED RIPRAP WITH THE OWNER AND PROJECT LANDSCAPE ARCHITECT. NO MORE THAN 25% OF ORDINARY RIPRAP ROCK SHALL REMAIN EXPOSED. FINISHED GRADE DEPICTED ABOVE SHALL BE FINISHED GRADE SPECIFIED ON GRADING PLANS. {GENERAL NOTES:} 1. 2. 3. 4. {\LPLACEMENT NOTES:} {FILTER FABRIC NOTES:} 1. 2. RP OPTIONAL UNDERDRAIN SOIL RIPRAP SEE NOTE 4 BELOW. SLOPE VARIES (SEE PLANS) 50 \A1;2*d SOIL RIPRAP \A1;4" TO 6" SOIL RIPRAP SOIL RIPRAP (ROCK-SOIL MIX) GRANULAR BEDDING TOPSOIL TRM TURF REINFORCEMENT MAT (TRM) TRM (SEE NOTE 5) TRM ENTRENCH 3" POINT A %%USECTION A-A POINTS A MUST BE HIGHER THAN POINT B %%UPLAN VIEW POINT B POINT A WATTLE POINT A FLOW POINT B POINT A WATTLE DIKE {DITCH INSTALLATION} A A THE CONTRACTOR SHALL INSPECT DIKES EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT UPSTREAM SEDIMENT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF DIKES SHALL BE REMOVED WHEN THE UPSTREAM SEDIMENT REACHES 1/2 OF THE DESIGN DEPTH. DIKES ARE TO REMAIN IN PLACE UNTIL THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED BY THE CITY. WHEN REINFORCED ROCK BERMS ARE REMOVED, ANY DISTURBED AREA SHALL BE SEEDED, CRIMPED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. {MAINTENANCE NOTES: }1. 2. 3. 4. WD STAKES SHOULD BE DRIVEN ACROSS FROM EACH OTHER AND ON EACH SIDE OF THE WATTLE. LEAVING 4"-6" OF STAKE PROTRUDING ABOVE THE WATTLE. BAILING WIRE OR NYLON ROPE SHOULD BE TIED TO THE STAKES ACROSS THE WATTLE. STAKES SHOULD THEN BE DRIVEN UNTIL THE BAILING WIRE OR NYLON ROPE IS SUFFICIENTLY SNUG TO THE WATTLE. STA %%uOR%%u OR (10" MIN. DIA.) 005 C6.01 002 C6.01 001 C6.01 003 C6.01 004 C6.01 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / F E S CO VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SW FRONTAGE ROAD INTERSTATE 25 PROPOSED CULVERT PROPOSED CULVERT PROPOSED CULVERT SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF SF WD SF VTC CWA SF SF SF SF WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD WD RP RP RP WD WD WD WD WD WD WD WD WD WD WD WD CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 80 0 80 Feet 80 160 240 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN LEGEND: 4953 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPERTY BOUNDARY BENCHMARK/BASIS OF BEARING: SILT FENCE SF SF RIPRAP w/ TURF REINFORCEMENT MAT RP 1. CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2. SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone________________________________ 3. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 4. REFER TO THE DRAINAGE REPORT - N/A BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. GENERAL NOTES: WATTLE DIKE WD CONCRETE WASH AREA CWA VERTICAL TRACKING CONTROL VTC PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 2-01 LOCATED ON THE NORTH SIDE OF HORSETOOTH ROAD ON THE CONCRETE BASE OF THE WEST GATE POST TO THE LARGE GRAVEL PIT APPROX. 1/2 MILE EAST OF ZIEGLER ROAD. ELEVATION=4861.39 CITY OF FORT COLLINS BENCHMARK 29-01 LOCATED ON THE SOUTH SIDE OF PROSPECT ROAD, EAST OF THE INTERSECTION OF THE WEST FRONTAGE ROAD OF I-25 AND PROSPECT ROAD, EAST OF THE COLORADO WELCOME CENTER, ON A CONCRETE HEADWALL TO AN IRRIGATION PIPE. ELEVATION=4904.41 BASIS OF BEARINGS ASSUMING THE NORTH LINE OF THE NORTHEAST QUARTER OF SECTION 21, T.7N., R.69W., AS BEARING NORTH 88°38'29" WEST BEING A GRID BEARING OF THE COLORADO STATE PLANE COORDINATE SYSTEM, NORTH ZONE, NORTH AMERICAN DATUM 1983/92, A DISTANCE OF 2642.40 FEET WITH ALL OTHER BEARINGS CONTAINED HEREIN RELATIVE THERETO. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C6.00 EROSION CONTROL PLANS B. Ruch M. Kuehnel 1"=80' 34 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 1. IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL AUTHORITIES. 2. THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR EXACT LOCATION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND FOLLOWED. 4. CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE STABILIZATION. 5. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL STORM DRAINS, SWALES, PONDS AND RAIN GARDENS UNTIL SITE IS FULLY STABILIZED. 6. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS ESTABLISHED WITH DOWNSPOUT. 7. INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL, SAND BAGS OR GRAVEL SOCKS FOR PAVEMENT, ETC.) 8. CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS, TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE. 9. ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO INSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. AT NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS. 10. CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, SAND BAGS OR GRAVEL SOCKS FOR PAVEMENT, ETC.) 11. FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. 12. CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS (CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND CONSTRUCTION TOILETS SHALL BE STAKED DOWN. 13. THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE. 14. WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS) INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION CONTROL STAFF TO PREVENT EROSION. 15. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING, REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION METHODS. TABLE OF CONSTRUCTION SEQUENCE AND BMP EROSION CONTROL NOTES: APPLICATION CONSTRUCTION PHASE (DESCRIPTION) PHASE I (GRADING) PHASE II (INFRASTRUCTURE) PHASE III (VERTICAL CONSTRUCITON) PHASE IV (PERMANENT BMP'S) Grading (Include Offsite) Overlot Pipeline Installation Stormwater Concrete Installation Site Walls Building Structure Miscellaneous Hardscape Amenities BEST MANAGEMENT PRACTICES Temporary Inlet Protection (IP) Vehicle Tracking Control (VTC) Flow Barriers (Wattles, Rock Socks, etc.) (RS) Concrete Washout Area (CWA) Preventative Maintenance Activities/Meetings/etc. Silt Fence (SF) Permanent Mulching/Sealant Permanent Seed Planting Sewer Service Water Service Curb and Gutter Rip Rap (RP) Erosion Control Fabric (EF) C6.00 Northern Engineering responses by: Benjamin Ruch Project Engineer Utility construction shown on other sheet is conceptual. Only the roadway and associated crossings will be completed in this phase of construction. All slopes are 4:1 max. It is the up to the contractor's discretion what method is used for stabilization during vegetation. Riprap is now shown in correct orientation. We have replaced the Wattle Dikes with Rock Socks to deal with the potential water velocities. All slopes are 4:1 max. It is the up to the contractor's discretion what method is used for stabilization during vegetation. We have replaced the Wattle Dikes with Rock Socks to deal with the potential water velocities. B. Ruch B. Ruch N/A 33 NOT TO SCALE 400 C5.03 TRENCH DETAIL 12" (Water & Sewer) If this section is less than 4' of existing asphalt/concrete, it must be removed and replaced. Edge of Pavement or Lip of Existing Gutter Compacted Lifts of Suitable Materials Pavement Thickness Varies Varies 1" (min.) (See Note 9 below for Storm.) 4" (min.) 6" (max.) Trench Width Varies 2' (min.) Bedding Material Undisturbed Soil Utility Conduit New Asphalt/Concrete Clean Road Base Existing Road Base 6" Full Depth Asphalt or X/Y Composite Section NOTES: 1. All trenches shall be backfilled in accordance with the above detail unless otherwise specified by the Local Entity Engineer. 2. Prior to placement of asphalt/concrete, pavement edge shall be saw cut to a clean, vertical, and straight edge. 3. Where the surrounding soils are non-expansive, a sand/cement slurry (1 sack mix) may be substituted for backfill material. 4. Trench width shall not be more than 16" nor less than 12" wider than the outside diameter of the pipe. 5. Use a #4 rebar at centers along the perimeter of concrete replacement sections. 6. Refer to Chapter 22, Materials & Construction Specifications for compaction and testing requirements. 7. In unimproved areas, all disturbed areas shall be regraded, seeded & mulched. 8. In concrete roadways, a minimum of one entire concrete panel must be replaced. 9. Bedding material depth when installing storm sewer shall be up to spring line, except in areas of unsuitable backfill; then, bedding material shall be placed to a level 12" above pipe. LARIMER COUNTY URBAN AREA STREET STANDARDS CONSTRUCTION DRAWINGS REVISION NO: 1 DRAWING 2201 DATE: 08/07/00 TRENCH DETAIL NOT TO SCALE 401 C5.03 PRELIMINARY PAVEMENT DETAIL LOCAL STREETS COLLECTOR ROADS *PAVING DEPTHS SHOWN ARE TAKEN FROM THE "PRELIMINARY SUBSURFACE EXPLORATION REPORT CSURF 25-ACRE PARCEL SOUTHWEST OF EAST PROSPECT ROAD AND 1-25" PREPARED BY EARTH ENGINEERING CONSULTANTS (EEC # 1072151) \A1;6" SUBGRADE \A1;4" ASPHALT \A1;8" SUBGRADE \A1;5" ASPHALT B. Ruch B. Ruch N/A 32 NOT TO SCALE 300 C5.02 STORMWATER BEDDING CLASS B BEDDING LOWER LIMIT OF UNIFORM GRADED CLASS A BEDDING LOWER LIMIT OF LOWER LIMIT OF MATERIAL TRENCH WIDTHS SHALL BE AS SPECIFIED ON PLANS. REFER TO THE STORM SRAINAGE CONSTRUCTION STANDARDS, SECTION 6, "BEDDING MATERIALS" FOR GRADATIONS. SUBDRAIN DETAIL TRENCH WIDTH AS SPECIFIED TRENCH WIDTH AS SPECIFIED ROCK EXCAVATION TRENCH WIDTH AS SPECIFIED GRANULAR MATERIAL UNSTABLE SUBGRADE TRENCH WIDTH AS SPECIFIED ROCK 1 1/2 IN. COMPACTED GRANULAR OR TRENCH WALL SLOPE COMPACTED MATERIAL GRANULAR %%UNOTES: 2. 1. 6 IN. MIN. 4 IN. MIN. \A1;1/8 PIPE O.D. OR 4 IN. MIN. SLOTTED PIPE PERFORATED OR GRAVEL FILTER BACKFILL COMPACTED DENSELY TRENCH WIDTH AS SPECIFIED CLASS C BEDDING TRENCH WIDTH AS SPECIFIED \A1;1/4 PIPE O.D. SLOPE MATERIAL COMPACTED TRENCH DENSELY WALL \A1;PIPE O.D. + 8 IN. \A1;1/4 PIPE O.D. MATERIAL COMPACTED DENSELY SLOPE TRENCH WALL MATERIAL \A1;PIPE O.D. OR 6 IN. MIN. \A1;1/8 PIPE O.D. 3000 CONCRETE P.S.I. TRENCH WALL LOWER LIMIT OF UNIFORMLY SELECTED GRADED SLOPE GRADED COMPACTED ROCK OR MATERIAL GRANULAR COMPACTED \A1;PIPE O.D. TRENCH WALL LOWER LIMIT OF SLOPE COMPACTED DENSELY FILTER 6 IN. MIN. \A1;PIPE O.D. \OR A1;4 1/IN. 8 PIPE MIN. O.D. \A1;PIPE O.D. BROKEN LARGE (IF CONCRETE, REQUIRED) STONES, ETC. MATERIAL LOWER LIMIT OF TRENCH WALL SLOPE APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 STORMWATER BEDDING REQUIREMENTS 1/12/00 D-1 SKC APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 CONCRETE END SECTIONS 01/31/01 D-15 NBJ E C B E E E E F F PLAN C B D A RISE SPAN END VIEW PLAN E F M 206 SEE FOR FIGURE ACTUAL 1 OF AASHTO SIZES SECTION D F-FA RISSEPAN END VIEW F 3 IN. 5 IN. 5 IN. 3 IN. F 2 FT. 5 IN. 3/4 IN. GALVANIZED ANCHOR BOLTS, NUTS AND WASHERS, MILD STEEL, ASTM A 307. ROD LUG SHALL BE COATED WITH COAL-TAR EPOXY PAINT OR APPROVED EQUAL. 3/4 IN. "CANOPY" APPROVED, TYPE ROD EQUAL LUG, OR 2 FT. 7 IN. PIPE DIAMETER F 18 IN. - 30 IN. 36 IN. - 42 IN. 48 IN. - 60 IN. 72 IN. - 84 IN. 5 IN. 6 IN. 9 IN. CONCRETE JOINT FASTENER. LOCATION OF 1 IN. DIA. HOLES END SECTION FOR REINFORCED CONCRETE CIRCULAR PIPE END SECTION FOR REINFORCED CONCRETE ELLIPTICAL PIPE END SECTION FOR REINFORCED CONCRETE ARCH PIPE DIMENSIONS A B C D E PIPE I.D. IN. 12 15 18 24 30 36 42 48 54 60 72 5 1/2 11 1/2 12 17 18 24 28 27 36 34 1/2 23 26 26 43 53 60 61 70 65 58 75 49 47 48 54 43 37 36 28 35 40 21 72 73 74 97 96 97 97 98 100 98 96 24 29 36 48 60 71 78 84 90 96 108 IN. IN. IN. IN. IN. SECTION F-F 24 30 36 42 48 54 60 30 38 45 53 60 68 76 19 24 29 34 38 43 48 8 1/2 9 1/2 11 1/8 15 3/4 21 25 1/2 30 39 54 60 60 60 60 60 33 18 24 36 36 36 36 72 72 84 96 96 96 96 48 60 72 78 84 90 96 EQUIVALENT (INCHES) CIRCULAR DIAM. (IN.) NOMINAL (IN.) DIMENSIONS SPAN RISE A B C D E 24 30 36 48 54 DIAM. (IN.) CIRCULAR EQUIVALENT 42 60 72 96 96 96 96 96 (INCHES) 96 8 1/2 9 1/2 11 1/8 25 1/2 A DIMENSIONS 15 3/4 SPAN RISE 30 21 NOMINAL (IN.) B C 60 60 60 60 50 60 39 36 36 36 36 46 35 33 78 90 96 84 D 60 72 48 E 29 36 43 50 58 65 72 86 18 22 27 31 36 40 44 54 31 120 72 60 39 99 PLAN SECTION X-X GENERAL NOTES: 1. REVISED CDOH M-603-10 2. CONCRETE END SECTIONS ARE TO BE FURNISHED WITH TOUGE OR GROOVE AS REQUIRED. 3. INSIDE CONFIGURATION AND JOINT OF CONCRETE END SECTION AND PIPE SHALL MATCH. 4. CONCRETE PIPE JOINT FASTENERS, WHERE SHOWN ON PLANS, SHALL BE INSTALLED SO THAT A MINIMUM OF 15 LINEAR FEET OF THE OUTLET END OF THE ARE MECHANICALLY LOCKED TOGETHER. END SECTION LENGHTS, WHEN USED, WILL BE INCLUDED IN THE 15 L.F. REQUIRED. END VIEW + NOTE: NON-SHRINK BACKFILL SHALL BE USED IN ALL PAVED AREAS. NON-SHRINK BACKFILL SHALL BE POURED TO WITHIN 4 IN. OF THE ASPHALT SURFACING AND ALLOWED TO SET A MINIUM OF THREE HOURS PRIOR TO PLACING ASPHALT. IF THE ASPHALT IS NOT PLACED THE SAME DAY, SLURRY SHALL BE POURED TO THE TOP OF THE ASPHALT, AND A MIMNUM OF THREE HOURS CURING TIME PRIOR TO PERMITTING TRAFFIC ON THE SLURRY: PRIOR TO PLACING THE ASPHALT SURFACING 4 IN. OF SLURRY MIX SHALL BE REMOVED, AND THE EXISTING PAVEMENT SQUARE CUT TO A MINIMUM OF ONE FOOT BEYOND THE TRENCH LINE. ASPHALT EDGES SHALL BE TREATED WITH A TACK COAT PRIOR TO PLACING THE PERMANENT PATCH. A MINIMUM OF FOUR INCHES OF HOT ASPHALT SHALL BE USED FOR THE PERMANENT PATCH. COLD MIX ASPHALT MAY BE USED AS A TEMPORARY PATCH UNTIL HOT MIX ASPHALT IS AVAILABLE. NON-SHRINK BACKFILL NON-SHRINK BACKFILL MIX INGREDIENTS, CEMENT - 0.45 SACK WATER - 39 GALLONS AIR (ENTRAPPED) - 1.5% COURSE AGGREGATE (1 IN. MAX. - SIZE 57) SAND (ASTM C-33) WEIGHT/C.Y. 42 LBS. 325 LBS. 1700 LBS. 1845 LBS. 3912 LBS. NON-SHRINK BACKFILL TO BE USED IN ALL PAVED SECTIONS OF DEPT. OF HIGHWAY RIGHT OF WAY. APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 NBJ 11-29-2000 D-30 NON-SHRINK BACKFILL (SLURRY) NOT TO SCALE 301 C5.02 CONCRETE END SECTIONS NOT TO SCALE 302 C5.02 NON-SHRINK BACKFILL (SLURRY) B. Ruch B. Ruch N/A 31 MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT NOT TO SCALE 201 C5.01 TRENCH BEDDING NOT TO SCALE 202 C5.01 CLAY CUT-OFF WALL NOT TO SCALE 203 C5.01 MANHOLE ELCO WATER DISTRICT DETAIL: DRAWN: DATE: 3-PIECE VALVE BOX GATE VALVE (AWWA C500) WATER LINE MECHANICAL JOINT GATE VALVE DETAIL BUTTERFLY VALVE (AWWA C504) VALVE BOX WATER LINE BUTTERFLY VALVE DETAIL WATER LINE MECHANICAL JOINT A A A-A VALVE DETAIL DLS NOTE: ALL VALVES OPEN LEFT MECHANICAL JOINT VALVE BOX SHALL BE SCREWED DOWN 6" & BURIED BELOW GRADE IF INSTALLED IN A NON-PAVED ROADWAY TRACER WIRE TAPED TO TOP OF PIPE "WATER" CAST IN TOP OF VALVE BOX COVER 2" OPERATING NUT OPEN LEFT 4'-0" MIN. 4'-0" MIN. BACKFILL TO BE HANDPLACED AND COMPACTED TOP OF VALVE BOX SHALL BE SET 1/8"-1/2" BELOW SURROUNDING ASPHALT 6" 2/00 SPECIFICATION 02641 NOT TO SCALE 200 C5.01 VALVE DETAIL Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} 970.221.4158 northernengineering.com of 35 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C5.00 UTILITY DETAILS B. Ruch B. Ruch N/A 30 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} NOT TO SCALE 100 C5.00 BEDDING REQUIREMENTS ELCO WATER DISTRICT DETAIL: TYPICAL FIRE HYDRANT INSTALLATION DRAWN: DATE: 5/00 SPECIFICATION 02644 FIRE HYDRANT PIPING, VALVES, ETC. SHALL BE WRAPPED IN WALLS OR FENCES ALLOWED WITHIN 4 FEET OF FIRE HYDRANT. NO LANDSCAPING (TREES, SCRUBS, BOULDERS, ETC.), RETAINING GATE VALVE RESILIENT SEAT POLYETHYLENE 8 MIL SHEET OF MUST REMAIN CLEAR OF 24 INCH MIN. CONCRETE BLOCK THRUST BLOCK 12 IN. POLYETHYLENE. HYDRANT GRAVEL 6" C-900 PVC PIPE OBSTRUCTIONS NOTES 18 IN. 0.1 FT.-0.2 FT. FLOW-FILL 12 IN. OR BACK OF CURB EDGE OF SIDEWALK HYDRANT DRAIN OPENINGS MINIMUM 30 INCHES 66 INCHES 54 INCHES MAXIMUM MINIMUM TRACE WIRE TERMINAL BOX THRUST BLOCK SWIVEL TEE MAIN ONLY) (PVC WATER TRACER WIRE VALVE BOX HIGH DENSITY DEVELOPMENT AREAS BOX INSTALLATION TRACE WIRE TERMINAL PLAN VIEW Fire Hydrant TRACE WIRE TERMINAL BOX INSTALLED EITHER RIGHT OR LEFT OF EACH FIRE HYDRANT ASSEMBLY HYDRANT: AWWA C502 w/ 1" OPERATING NUT SQUARE OPEN RIGHT OFFSET TO SIDE - SEE PLAN VIEW PAVEMENT Color: #5009 Equipment Yellow Brand: Aervoe Supreme Rust Shield Approved Paint: REVISED: 09/09 ADAPTED FROM CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS. REM MEGALUG DETACHED WALK (ALTERNATE) PROPERTY LINE ELCO WATER DISTRICT DETAIL: TYPICAL THRUST RESTRAINT DRAWN: REM 8/DATE: 00 SPECIFICATION: 02713 Swivel tee Anchor coupling Valve Valve Concrete thrust block- See Typical Thrust Blocks Detail Water main NOTE: IN-LINE VALVES DO NOT REQUIRE ANCHOR COUPLING RESTRAINT ELCO WATER DISTRICT DETAIL: DRAWN: DATE: MIN. THRUST AREA CASE A MIN. THRUST AREA CASE B AREA MIN. THRUST MIN. THRUST AREA CASE C CASE D TYPICAL THRUST BLOCKS RKB 7/92 AREA MIN. THRUST BEARING AREAS FOR VARIOUS FITTINGS (FT 2 ) SIZE TEE & PLUG 90%%D BEND 45%%D BEND 22 1/2%%D BEND 11 1/4%%D BEND NOTE: 1: ALL CONCRETE SHALL BE POURED AGAINST UNDISTURBED EARTH. 2: THRUST BLOCKS SHALL BE USED FOR ALL _ BENDS > 11 1/4 ° & ALL PLUGS. 3: ALL FITTINGS & PLUGS MUST BE WRAPPED WITH POLYETHYLENE TO PREVENT CONCRETE FROM ADHERING TO THE BOLTS OR PIPE. SPECIFICATION: 02713 & 03300 ELCO WATER DISTRICT DETAIL: TRACE WIRE TERMINAL BOX DETAIL DRAWN: DLS DATE: 10/98 SPECIFICATION 02622 WATER DROP LID - TOP VIEW DROP LID - SIDE VIEW TOP - SIDE VIEW BOX AND LID DETAIL NOT TO SCALE Box installed to grade - to either rigt or left of all new fire hydrant assemblies \A1;18" Trace wire, 12-guage insulated stranded copper Clean 3/4 inch rock French drain well INSTALLATION DETAIL NOT TO SCALE Note: Box and lid assembly shall be cast iron Tyler Slip-Type model 6865 (top only) or approved equal. REVISED: 3/06 ELCO WATER DISTRICT DETAIL: DRAWN: DATE: TRENCH WIDTH TABLE PVC PIPE DUCTILE IRON PIPE AC PIPE PIPE DIAMETER (inches) MAXIMUM TRENCH WIDTH (inches) PIPE DIAMETER (inches) (inches) TRENCH WIDTH MAXIMUM PIPE DIAMETER (inches) (inches) TRENCH WIDTH MAXIMUM 4 28 6 30 8 32 10 34 12 36 14 38 16 40 18 42 24 46 4 28 6 30 8 32 10 34 12 36 4 28 6 32 8 32 10 36 12 36 14 42 16 42 18 44 24 48 SEE TRENCH WIDTH TABLE BELOW PIPE TRENCH DETAIL RKB 10/91 12" MIN. SPECIFICATION: 02221 NOT TO SCALE FIRE HYDRANT WATER MAIN LOWERING TYPICAL THRUST RESTRAINT TYPICAL THRUST BLOCKS TRACE WIRE TERMINAL BOX TRENCH DETAIL 101 C5.00 102 C5.00 103 C5.00 106 C5.00 105 C5.00 104 C5.00 1 2 3 4 D D Culvert 2 4898.49 4896.15 4896.15 4898.41 36" RCP Sanitary A2 4895.16 4892.22 4892.22 4895.08 12" PVC Culvert 3 4894.47 4890.81 4890.81 4894.58 2-36" RCP 1 2 3 4 EVCE: 4901.91 A.D. = 1.00 K = 120.00 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING FRONTAGE ROAD INTERSTATE 25 SW FRONTAGE ROAD 28' EOP-EOP CULVERT 3 SEE SHEET C2.20 FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT TEMPORARY FRONTAGE ROAD CONNECTION 4:1 4:1 4:1 4:1 4:1 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C4.00 C4.01 C4.02 ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 C4.02 PLAN & PROFILE SW FRONTAGE ROAD-INTERIM B. Ruch B. Ruch 1"=40' 29 CENTERLINE SW FRONTAGE ROAD-INTERIM SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 25+50 / / / / / / / / / / / / / / / / EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 4. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY EASEMENT LINE EXISTING LOT LINE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT EXISTING EDGE OF ASPHALT / / / / / / / / / / / / / / / / EXISTING STORM SEWER INTERSTATE ACCESS MATCH LINE SEE SHEET C4.01 STA 25+50 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) EVCE: 4899.22 A.D. = 1.20 K = 100.00 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE 36" RCP STORM STA.=25+23.50 INV.=4892.59 36" RCP STORM STA.=25+31.26 INV.=4892.63 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SW FRONTAGE ROAD 28' EOP-EOP CULVERT 3 SEE SHEET C2.20 FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT 4:1 4:1 4:1 4:1 4:1 FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C4.00 C4.01 C4.02 ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 C4.01 PLAN & PROFILE SW FRONTAGE ROAD-INTERIM B. Ruch B. Ruch 1"=40' 28 CENTERLINE SW FRONTAGE ROAD-INTERIM SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 17+50 MATCH LINE SEE SHEET C4.02 STA 25+50 / / / / / / / / / / / / / / / / EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 4. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY EASEMENT LINE EXISTING LOT LINE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT EXISTING EDGE OF ASPHALT / / / / / / / / / / / / / / / / EXISTING STORM SEWER INTERSTATE ACCESS MATCH LINE SEE SHEET C4.00 STA 17+50 LINE MATCH STA 25+50 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) EVCS: 15+00.05 EVCE: 4904.82 A.D. = 1.20 K = 112.50 PROPOSED GRADE EXISTING GROUND EXISTING GROUND PROPOSED GRADE 36" RCP STORM STA.=13+93.61 INV.=4897.93 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X M / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / REST AREA ACCESS RD SW FRONTAGE ROAD 28' EOP-EOP CULVERT 1 SEE SHEET C2.20 CULVERT 2 SEE SHEET C2.20 FUTURE 15' UTILITY EASEMENT EXISTING CONCRETE IRRIGATION STRUCTURE 6:1 6:1 4:1 4:1 FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C4.00 C4.01 C4.02 ( IN FEET ) 1 inch = ft. 40 0 40 Feet 40 80 120 C4.00 PLAN & PROFILE SW FRONTAGE ROAD-INTERIM B. Ruch B. Ruch 1"=40' 27 CENTERLINE SW FRONTAGE ROAD-INTERIM SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 17+50 MATCH LINE SEE SHEET C4.01 STA 17+50 / / / / / / / / / / / / / / / / EXISTING RIGHT-OF-WAY LEGEND: PROPOSED STORM SEWER PROPOSED CENTERLINE PEDESTRIAN ACCESS RAMPS PROPOSED CONCRETE CROSSPAN (TYP.) PROPOSED RIGHT-OF-WAY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 3. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 4. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. PROPERTY BOUNDARY EASEMENT LINE EXISTING LOT LINE EXISTING LIGHT POLE PROPOSED EDGE OF ASPHALT EXISTING EDGE OF ASPHALT / / / / / / / / / / / / / / / / EXISTING STORM SEWER INTERSTATE ACCESS 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X ST / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / F E S CO VAULT ELEC E T ST ST ST E ST ST 97.65 98.21 99.51 0.26 92.34 92.92 93.18 91.88 91.27 (89.14) (88.00) 89.70 90.99 0.5% 0.5% 2.0% 0.5% 0.5% 0.5% 0.5% 0.5% 96.28 SW FRONTAGE ROAD INTERSTATE 25 TIE TO EXISTING FRONTAGE ROAD TIE TO EXISTING FRONTAGE ROAD (3.40) (3.34) 2.75 0.78 TIE TO EXISTING ROAD 99.31 99.89 98.91 96.02 93.97 94.69 CULVERT 1 SEE SHEET C2.20 CULVERT 2 SEE SHEET C2.20 CULVERT 3 SEE SHEET C2.20 (3.05) (2.65) (0.44) (0.44) 7:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1 4:1 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH LEGEND: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL PROJECT DATA IS ON VERTICAL DATUM; NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5013 PROPOSED CONTOUR EXISTING STORM SEWER PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION PROPOSED SLOPES 2.0%%% EXISTING SPOT ELEVATION (47.45) EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS ( IN FEET ) 1 inch = ft. 80 0 80 Feet 80 160 240 C3.00 OVERALL GRADING PLAN B. Ruch M. Kuehnel 1"=80' 26 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 C3.00 FES 1-1 STA 10+59.33 N: 122348.48 E: 214408.90 FES 1 STA 10+00.00 N: 122289.15 E: 214408.84 59.33 LF 12" RCP @ 1.30% 12" WATER LINE SEE SHEET C2.01-C2.02 PROPOSED 8' x 8' x 1.5' DEEP TYPE L RIPRAP PAD 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 11+50 11+00 10+00 9+50 4899.51 4903.79 4902.71 4900.46 59.33 LF 12" RCP @ 1.30% FES 1 STA 10+00.00 INV. 4899.50 (N) FES 1-1 STA 10+59.33 INV. 4900.26 (S) PROPOSED GROUND EXISTING GROUND EXISTING GROUND PROPOSED GROUND 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 12+00 11+00 10+00 9+50 4897.64 4901.52 4904.91 4904.34 4900.36 4898.29 4898.47 FES 2-1 STA 11+13.99 INV. 4898.21 (W) FES 2 STA 10+00.00 INV. 4897.64 (E) 113.99 LF 36" RCP @ 0.50% PROPOSED GROUND EXISTING GROUND EXISTING GROUND PROPOSED GROUND 18" MIN. 12" PVC WATER STA.=10+66.99 TOP=4896.15 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 12+00 11+00 10+00 9+50 4892.34 4899.69 4899.12 4895.14 4893.05 4894.68 113.99 LF 36" RCP @ 0.50% FES 3A-1 STA 11+17.70 INV. 4892.88 (SW) FES 3A STA 10+00.00 INV. 4892.30 (NE) PROPOSED GROUND EXISTING GROUND EXISTING GROUND PROPOSED GROUND 18" MIN. 12" PVC WATER STA.=10+66.98 TOP=4890.82 E E ST / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / FES 2-1 STA 11+13.99 N: 122187.34 E: 214544.99 FES 2 STA 10+00.00 N: 122148.46 E: 214437.84 113.99 LF 36" RCP @ 0.50% 12" WATER LINE SEE SHEET C2.01-C2.02 28' EOP-EOP FUTURE 12" PVC SANITARY SEWER SANITARY LINE A SEE SHEET C2.10 PROPOSED 8' x 8' x 1.5' DEEP TYPE L RIPRAP PAD / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SW FRONTAGE ROAD FES 3B-1 STA 11+13.99 N: 121632.61 E: 215452.58 FES 3A-1 STA 11+17.70 N: 121637.99 E: 215446.97 FES 3B STA 9+99.35 N: 121550.32 E: 215373.71 FES 3A STA 10+00.00 N: 121555.69 E: 215368.10 113.99 LF 36" RCP @ 0.50% 113.99 LF 36" RCP @ 0.50% 12" WATER LINE SEE SHEET C2.01-C2.02 28' EOP-EOP PROPOSED 8' x 20' x 1.5' DEEP TYPE L RIPRAP PAD No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner CULVERT 1 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.20 PLAN & PROFILE CULVERTS 1, 2, & 3 B. Ruch B. Ruch 1"=50' 25 NORTH CULVERT 1 PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: NOTES: W EXISTING SANITARY SEWER SS PROPOSED STORM INLET PROPOSED CURB & GUTTER PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED LOT LINE EXISTING EASEMENT LINE PROJECT BOUNDARY EXISTING RIGHT OF WAY EXISTING STORM SEWER PROPOSED EASEMENT LINE 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL STORM DRAINS, SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 3. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 4. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE TOWN OF BERTHOUD. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). 5. CONTRACTOR SHALL SHALL CONFIRM THAT MANHOLE DIAMETERS ARE SUFFICIENT FOR THEIR PROPOSED METHODS OF INSTALLATION (i.e., WITHIN PRE-CASTER'S TOLERANCES, ETC.). PROPOSED RIGHT OF WAY PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' CULVERT 2 CULVERT 3 NORTH NORTH CULVERT 2 CULVERT 3 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) W W W W W FO FO FO FO FO FO FO FO FO FO FO FO FO OHE OHE OHE FO FO FO FO FO FO FO FO FO FO FO FO FO OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SSMH B8 STA 36+82.73 N: 120884.21 E: 215616.43 SSMH B6 STA 30+35.62 N: 120237.22 E: 215628.81 SSMH B7 STA 34+35.62 N: 120637.15 E: 215621.68 400.00 LF 12" PVC @ 0.22% 247.11 LF 12" PVC @ 0.22% FUTURE 84' ROW INTERSTATE 25 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) 139.75 LF 12" PVC @ 0.22% SSMH B10 STA 40+02.67 N: 121203.35 E: 215593.78 SW FRONTAGE ROAD 12" WATER LINE SEE SHEET C2.01-C2.02 SS STUB B9 STA 38+62.92 N: 121063.95 E: 215603.68 180.19 LF 12" PVC @ 0.22% EXISTING FRONTAGE ROAD No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C2.18 C2.17 C2.16 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.18 PLAN & PROFILE FUTURE SANITARY LINE B B. Ruch B. Ruch 1"=50' 24 FUTURE SANITARY LINE B PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT MATCH LINE SEE SHEET C2.17 STA 31+50 LINE MATCH STA 31+50 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SSMH B6 STA 30+35.62 N: 120237.22 E: 215628.81 SSMH B5 STA 27+38.41 N: 119944.42 E: 215679.81 297.21 LF 12" PVC @ 0.22% 400.00 LF 12" PVC @ 0.22% 400.00 LF 12" PVC @ 0.22% SSMH B4 STA 23+38.41 N: 119550.35 E: 215748.45 FUTURE 84' ROW INTERSTATE 25 APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 EXISTING FRONTAGE ROAD No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C2.18 C2.17 C2.16 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.17 PLAN & PROFILE FUTURE SANITARY LINE B B. Ruch B. Ruch 1"=50' 23 FUTURE SANITARY LINE B PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT MATCH LINE SEE SHEET C2.18 STA 31+50 LINE MATCH STA 20+50 MATCH LINE SEE SHEET C2.16 STA 20+50 LINE MATCH STA 31+50 W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SS SS SS SS SS SS SS SS S SSMH B STA 10+00.00 N: 118229.76 E: 215952.32 SSMH B3 STA 19+38.41 N: 119156.29 E: 215817.10 SSMH B2 STA 15+38.41 N: 118762.22 E: 215885.74 SSMH B1 STA 11+38.41 N: 118368.16 E: 215954.39 138.41 LF 12" PVC @ 0.22% 400.00 LF 12" PVC @ 0.22% 400.00 LF 12" PVC @ 0.22% APPROXIMATE LOCATION EXISTING 30" SANITARY SEWER (BOXELDER) 60'UTILITY & ACCESS EASEMENT #2 REC. NO. 95055231 FUTURE 84' ROW INTERSTATE 25 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) EXISTING FRONTAGE ROAD No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C2.18 C2.17 C2.16 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.16 PLAN & PROFILE FUTURE SANITARY LINE B B. Ruch B. Ruch 1"=50' 22 FUTURE SANITARY LINE B PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT MATCH LINE SEE SHEET ##### STA 20+50 LINE MATCH STA 20+50 57.82 LF 12" PVC @ 0.22% 4896.61 4900.74 4900.57 PROPOSED GROUND EXISTING GROUND E E E E E E E E E FO FO FO FO FO FO FO FO / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SSMH A2-3 STA 18+88.20 N: 122583.56 E: 215101.24 213.98 LF 12" PVC @ 0.22% SSMH A2-4 STA 21+02.18 N: 122377.13 E: 215157.61 191.46 LF 12" PVC @ 0.22% SSMH A2-5 STA 22+93.64 N: 122186.55 E: 215139.25 220.14 LF 12" PVC @ 0.22% SSMH A2-6 STA 25+13.78 N: 121980.99 E: 215060.48 162.32 LF 12" PVC @ 0.22% SSMH A2-8 STA 27+33.92 N: 121775.43 E: 214981.71 SS STUB A2-9 STA 27+91.74 N: 121721.43 E: 214961.02 SW FRONTAGE ROAD 12" WATER LINE SEE SHEET C2.01-C2.02 57.82 LF 12" PVC @ 0.22% 57.82 LF 12" PVC @ 0.22% SS STUB A2-7 STA 26+76.10 N: 121829.42 E: 215002.40 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C2.14 C2.15 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.15 PLAN & PROFILE FUTURE SANITARY LINE A2 B. Ruch B. Ruch 1"=50' 21 FUTURE SANITARY LINE A2 PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT LINE MATCH STA 19+50 MATCH LINE SEE SHEET C2.14 STA 19+50 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) FO FO FO E E E E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X SSMH A2 STA 10+00.00 N: 123116.25 E: 214655.28 338.59 LF 12" PVC @ 0.22% SSMH A2-1 STA 13+38.59 N: 123119.98 E: 214993.84 186.94 LF 12" PVC @ 0.22% SW FRONTAGE ROAD FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 SSMH A2-2 STA 15+25.53 N: 122933.41 E: 215005.70 362.67 LF 12" PVC @ 0.22% SSMH A2-3 STA 18+88.20 N: 122583.56 E: 215101.24 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C2.14 C2.15 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.14 PLAN & PROFILE FUTURE SANITARY LINE A2 B. Ruch B. Ruch 1"=50' 20 FUTURE SANITARY LINE A2 PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT MATCH LINE SEE SHEET C2.15 STA 19+50 LINE MATCH STA 14+50 LINE MATCH STA 14+50 LINE MATCH STA 19+50 NORTH E E E E E E E E E E E FO FO FO FO ST W FO FO FO FO FO E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SSMH A5 STA 22+76.97 N: 122156.06 E: 214419.26 277.31 LF 12" PVC @ 0.25% SSMH A7 STA 25+54.28 N: 121891.86 E: 214335.00 292.79 LF 12" PVC @ 0.22% SSMH A8 STA 28+47.07 N: 121599.19 E: 214326.53 292.79 LF 12" PVC @ 0.22% SSMH A9 STA 31+39.86 N: 121306.52 E: 214318.06 12" WATER LINE SEE SHEET C2.01-C2.02 SW FRONTAGE ROAD 270.79 LF 12" PVC @ 0.22% SANITARY LINE A SEE SHEET C2.10 CULVERT 1 SEE SHEET C2.20 CULVERT 2 SEE SHEET C2.20 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C2.12 C2.13 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.13 PLAN & PROFILE FUTURE SANITARY LINE A B. Ruch B. Ruch 1"=50' 19 FUTURE SANITARY LINE A PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT LINE MATCH STA 20+50 MATCH LINE SEE SHEET C2.12 STA 20+50 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) E E E E E E E E E FO FO FO FO FO FO FO FO FO E E E E E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X SS SS SS SS SS SS S S SW FRONTAGE ROAD EXMH A STA 10+00.00 N: 123177.56 E: 214389.62 SSMH A1 STA 11+47.58 N: 123114.79 E: 214523.18 147.58 LF 12" PVC @ 0.22% 132.10 LF 12" PVC @ 0.22% SSMH A2 STA 12+79.68 N: 123116.25 E: 214655.28 212.82 LF 12" PVC @ 0.22% FUTURE SANITARY LINE A2 SEE SHEET C2.14-C2.15 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 20' SEWER EASEMENT BK. 1958 PG. 541 1979 20' SEWER EASEMENT BK. 1958 PG. 535 1979 APPROXIMATE LOCATION EXISTING 27" SANITARY SEWER (BOXELDER) APPROXIMATE LOCATION 18" SANITARY SEWER (BOXELDER) E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO ST FO FO FO FO FO FO FO FO FO FO FO E E E E E E E E E E E E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X X M / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / REST AREA ACCESS RD SW FRONTAGE ROAD 212.82 LF 12" PVC @ 0.22% SSMH A3 STA 14+92.50 N: 122903.44 E: 214657.62 346.96 LF 12" PVC @ 0.22% SSMH A4 STA 18+39.46 N: 122572.88 E: 214552.20 166.71 LF 12" PVC @ 0.22% FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 SS STUB A4 STA 20+06.18 N: 122414.05 E: 214501.54 SANITARY LINE A SEE SHEET C2.10 CULVERT 1 SEE SHEET C2.20 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C2.12 C2.13 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.12 PLAN & PROFILE FUTURE SANITARY LINE A B. Ruch B. Ruch 1"=50' 18 FUTURE SANITARY LINE A PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT MATCH LINE SEE SHEET C2.13 STA 20+50 LINE MATCH STA 13+50 LINE MATCH STA 13+50 LINE MATCH STA 20+50 NORTH OHE FO FO FO FO FO FO FO FO FO FO FO OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE X X X X X X X X VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / INTERSTATE 25 12" WATER LINE SEE SHEET C2.01-C2.02 139.75 LF 12" PVC @ 0.22% SSMH B10 STA 40+02.67 N: 121203.35 E: 215593.78 SW FRONTAGE ROAD SS STUB B9 STA 38+62.92 N: 121063.95 E: 215603.68 FUTURE 12" PVC WATER FUTURE 12" PVC SANITARY SEWER FUTURE 15' UTILITY EASEMENT 28' EOP-EOP FUTURE SANITARY LINE B SEE SHEET C2.16-C2.18 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH SANITARY LINE B ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.11 PLAN & PROFILE SANITARY LINE B B. Ruch B. Ruch 1"=50' 17 SANITARY LINE B PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) E E E E E E FO FO FO FO FO FO FO FO ST W FO FO FO FO FO FO FO FO E E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / M / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SSMH A5 STA 22+76.97 N: 122156.06 E: 214419.26 12" WATER LINE SEE SHEET C2.01-C2.02 SW FRONTAGE ROAD SS STUB A4 STA 20+06.18 N: 122414.05 E: 214501.54 270.79 LF 12" PVC @ 0.22% FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC SANITARY SEWER CULVERT 2 SEE SHEET C2.20 FUTURE 12" PVC WATER CULVERT 1 SEE SHEET C2.20 28' EOP-EOP FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / SW FRONTAGE ROAD 12" WATER LINE SEE SHEET C2.01-C2.02 28' EOP-EOP SS STUB A2-7 STA 26+76.10 N: 121829.42 E: 215002.40 57.82 LF 12" PVC @ 0.22% SSMH A2-8 STA 27+33.92 N: 121775.43 E: 214981.71 57.82 LF 12" PVC @ 0.22% SS STUB A2-9 STA 27+91.74 N: 121721.43 E: 214961.02 FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC SANITARY SEWER PROPOSED 8" PVC WATER 15' UTILITY EASEMENT FUTURE SANITARY LINE A2 SEE SHEET C2.14-C2.15 FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT 4880 4885 4890 4895 4900 4905 4910 4915 4920 4880 4885 4890 4895 4900 4905 4910 4915 4920 26+00 27+00 28+00 28+50 EXISTING GROUND PROPOSED GROUND 4896.61 4900.74 4900.57 EXISTING GROUND PROPOSED GROUND SS STUB A2-7 STA 26+76.10 INV. 4893.64 (S) INV. 4893.64 (N) 57.82 LF 12" PVC @ 0.22% 57.82 LF 12" PVC @ 0.22% SS STUB A2-9 STA 27+91.74 INV. 4894.09 (S) INV. 4894.09 (N) SSMH A2-8 STA 27+33.92 RIM 4900.9± INV. IN 4893.97 (S) INV. OUT 4893.77 (N) FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC SANITARY SEWER No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner SANITARY LINE A SANITARY LINE A2 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 C2.10 PLAN & PROFILE SANITARY LINES A & A2 B. Ruch B. Ruch 1"=50' 16 SANITARY LINE A PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITATION DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS. 3. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND SUBDRAIN CLEANOUTS WITHIN THE RIGHT-OF-WAY PER TOWN STANDARDS. ALL MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1 4" BELOW FINISHED GRADE. CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, SERVICES AND UNDERDRAINS. 6. ALL SANITARY MANHOLES TO BE 4'Ø. 7. GROUNDWATER BARRIERS SHALL BE PLACED PER BOXELDER SANITATION DISTRICT STANDARDS. EXISTING LOT LINE EXISTING RIGHT OF WAY PROPOSED RIGHT OF WAY INTERSTATE ACCESS MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT NORTH SANITARY LINE A2 PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) FUTURE SANITARY LINE B SEE SHEET C2.16-C2.18 STA.=71+22.21 BEGIN HORZ. DEFL. N: 118369.87 E: 215964.24 12"x6" SWIVEL TEE w/ 12" BFV (S), 6" GV (E), & FH ASSEMBLY N:118739.14 E:215899.91 FUTURE 84' ROW FH ASSEMBLY N:118742.31 E:215918.14 FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT X X X X X X X X S SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W APPROXIMATE LOCATION 30" SANITARY SEWER (BOXELDER) APPROXIMATE LOCATION 2 1/2" WATER LINE (ELCO) 286.03 LF 12" PVC N79°01'47"E 181.87 LF 12" PVC S89°07'12"E 18.24 LF 12" PVC S00°52'48"W 112.70 LF 12" PVC R=600.00' STA.=71+22.21 BEGIN HORZ. DEFL. N: 118369.87 E: 215964.24 STA.=72+34.91 END HORZ. DEFL. N: 118257.69 E: 215973.07 STA. 74+35.02 11.25° BEND w/ TB & 12" BFV (W) N:118236.66 E:216154.64 STA.=77+21.05 CUT IN 2 1/2"x12" TEE w/ TB 12" BFV (W), & 2" GV (S) N: 118291.09 E: 216435.44 APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) INTERSTATE 25 STA. 72+53.15 90.00° BEND w/ TB N:118239.45 E:215972.79 60'UTILITY & ACCESS EASEMENT #2 REC. NO. 95055231 EXISTING FRONTAGE ROAD No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EXISTING LOTLINE EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 6. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS C2.08 PLAN & PROFILE FUTURE 12" WATER LINE B. Ruch B. Ruch 1"=50' 15 FUTURE 12" WATER LINE PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' LINE MATCH STA 65+50 MATCH LINE SEE SHEET C2.07 STA 65+50 LINE MATCH STA 71+50 LINE MATCH STA 71+50 NORTH C2.03 C2.04 C2.05 C2.06 C2.07 C2.08 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W INTERSTATE 25 498.25 LF 12" PVC S09°52'53"E 500.00 LF 12" PVC S09°52'53"E 477.65 LF 12" PVC S09°52'53"E APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) 12"x6" SWIVEL TEE w/ 12" BFV (S), 6" GV (W), & FH ASSEMBLY N:119722.58 E:215728.60 12"x6" SWIVEL TEE w/ 12" BFV (S), 6" GV (E), & FH ASSEMBLY N:119230.00 E:215814.41 FUTURE 84' ROW FH ASSEMBLY N:119715.97 E:215690.68 FH ASSEMBLY N:119233.17 E:215832.63 EXISTING FRONTAGE ROAD EXISTING FRONTAGE ROAD FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EXISTING LOTLINE EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 6. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS C2.07 PLAN & PROFILE FUTURE 12" WATER LINE B. Ruch B. Ruch 1"=50' 14 FUTURE 12" WATER LINE PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' MATCH LINE SEE SHEET C2.08 STA 65+50 LINE MATCH STA 53+50 MATCH LINE STA SEE SHEET C2.06 53+50 LINE MATCH STA 65+50 C2.03 C2.04 C2.05 C2.06 C2.07 C2.08 STA. 48+04.1 0.3° DEFLECTION T.O.P.=4895.00 STA. 47+49.13 12"x6" SWIVEL TEE T.O.P.=4894.77 STA. 43+98.88 12" STUB w/ PLUG T.O.P.=4893.45 STA. 45+79.08 BEGIN HORZ. DEFL. T.O.P.=4894.05 STA. 51+80.25 BEGIN HORZ. DEFL. T.O.P.=4894.58 STA. 46+11.42 END HORZ. DEFL. T.O.P.=4894.18 STA. 52+71.49 END HORZ. DEFL. T.O.P.=4894.48 STA. 52+49.13 12"x6" SWIVEL TEE T.O.P.=4894.51 28.5' DEF. STA. 43+98.88 T.O.P.=4893.45 STA. 44+27.35 T.O.P.=4893.41 (@ 0.4°) W W W W W W W W W W W W W W FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO OHE OHE OHE OHE FO FO FO FO FO FO FO FO FO FO FO FO FO FO OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / W W W W W W W W W W W W 431.11 LF 12" PVC S01°01'15"E 137.71 LF 12" PVC S01°01'15"E 32.35 LF 12" PVC R=610.00' 10.00 LF 12" PVC R=610.00' 68.89 LF 12" PVC R=590.00' 22.35 LF 12" PVC R=590.00' SW FRONTAGE ROAD FUTURE SANITARY LINE B SEE SHEET C2.16-C2.18 STA.=42+49.13 12"x6" SWIVEL TEE w/ 12" BFV (S), & 6" GV (E) N: 121214.03 E: 215602.97 STA.=42+59.13 END HORZ. DEFL. N: 121204.06 E: 215603.76 APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) STA.=45+79.08 BEGIN HORZ. DEFL. N: 120884.92 E: 215626.41 STA.=51+80.25 BEGIN HORZ. DEFL. N: 120283.88 E: 215637.98 INTERSTATE 25 STA.=52+71.49 END HORZ. DEFL. N: 120193.14 E: 215646.64 STA.=46+11.42 END HORZ. DEFL. N: 120852.61 E: 215627.84 FUTURE 84' ROW STA.=52+49.13 12"x6" SWIVEL TEE w/ 12" BFV (S), & 6" GV (E) N: 120215.23 E: 215643.22 SANITARY LINE B SEE SHEET C2.11 139.75 LF 12" PVC S04°03'34"E STA. 43+98.88 12" STUB w/ PLUG N:121064.66 E:215613.65 FH ASSEMBLY N:120715.25 E:215648.79 FH ASSEMBLY N:121210.68 E:215564.62 FH ASSEMBLY N:120217.71 E:215661.55 180.19 LF 12" PVC S04°03'34"E STA. 47+49.13 12"x6" SWIVEL TEE w/ 12" BFV (S) & 6" GV (E) N:120714.92 E:215630.29 EXISTING FRONTAGE ROAD FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EXISTING LOTLINE EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 6. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS C2.06 PLAN & PROFILE FUTURE 12" WATER LINE B. Ruch B. Ruch 1"=50' 13 FUTURE 12" WATER LINE PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' LINE MATCH STA 41+50 MATCH LINE SEE SHEET C2.07 STA 53+50 LINE MATCH STA 53+50 MATCH LINE SEE SHEET C2.05 STA 41+50 C2.03 C2.04 C2.05 C2.06 C2.07 C2.08 4900.93 4901.17 12" PVC 12" PVC 12" PVC 12" PVC STA. 33+24.5 44.9° DEFLECTION T.O.P.=4895.16 STA. 33+27.4 45.0° DEFLECTION T.O.P.=4892.22 STA. 33+37.4 45.0° DEFLECTION T.O.P.=4892.22 STA. 33+40.3 45.1° DEFLECTION T.O.P.=4895.08 STA. 37+97.6 45.1° DEFLECTION T.O.P.=4894.47 STA. 38+01.3 45.0° DEFLECTION T.O.P.=4890.81 STA. 38+19.0 45.0° DEFLECTION T.O.P.=4890.81 STA. 38+22.8 44.9° DEFLECTION T.O.P.=4894.58 STA. 33+45.74 12"x8" CROSS T.O.P.=4895.05 STA. 34+05.52 12"x6" SWIVEL TEE T.O.P.=4894.76 STA. 34+64.34 BEGIN HORZ. DEFL. T.O.P.=4894.47 STA. 32+86.15 END HORZ. DEFL. T.O.P.=4895.35 STA. 39+05.52 12"x6" SWIVEL TEE T.O.P.=4894.94 100.0' DEF. STA. 35+71.82 T.O.P.=4893.93 STA. 36+71.82 T.O.P.=4893.91 (@ 0.1°) EXISTING GROUND PROPOSED GROUND TOP OF WATER PIPE PROPOSED GROUND 18" MIN. \A1;18" MIN. 18" MIN. RESTRAIN ALL JOINTS STA.=32+99.5 STA.=33+65.3 RESTRAIN ALL JOINTS STA.=37+72.6 STA.=38+47.8 12" PVC SANITARY STA.=33+32.44 INV.=4893.74 36" RCP STORM STA.=38+06.28 INV.=4892.64 36" RCP STORM STA.=38+14.04 INV.=4892.68 W W W W W W W FO FO FO FO FO FO E E E E FO FO FO FO OHE OHE OHE OHE OHE OHE OHE OHE X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) 58.82 LF 12" PVC S78°42'43"E 4 4 1 . 1 8 L F 12 " P V C R = 6 1 0 . 0 0 ' 3 40 . 6 3 L F 1 2 " PV C R =5 9 0.00 ' 343 . 61 L F 1 2 " P V C R = 61 0 .0 0 ' SW FRONTAGE ROAD FUTURE SANITARY LINE A2 SEE SHEET C2.14-C2.15 STA.=32+86.15 END HORZ. DEFL. N: 121793.96 E: 214939.95 STA.=34+64.34 BEGIN HORZ. DEFL. N: 121759.08 E: 215114.69 28' EOP-EOP STA.=39+05.52 12"x6" SWIVEL TEE w/ 12" BFV (SE), & 6" GV (SW) N: 121530.31 E: 215480.70 INTERSTATE 25 SANITARY LINE A2 SEE SHEET C2.10 CULVERT 3 SEE SHEET C2.20 59.58 LF 12" PVC S78°42'43"E 59.79 LF 12" PVC S78°42'43"E STA. 33+45.74 12"x8" CROSS w/ 12" BFV (E) & 2-8" GV (N,S) N:121782.30 E:214998.38 FH ASSEMBLY N:121732.84 E:215049.47 FH ASSEMBLY N:121923.25 E:214615.95 FH ASSEMBLY N:121506.99 E:215450.06 STA. 34+05.52 12"x6" SWIVEL TEE w/ 6" GV (S) N:121770.59 E:215057.01 8" STUB w/ PLUG N:121827.43 E:215012.35 8" STUB w/ PLUG N:121717.96 E:214978.43 FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EXISTING LOTLINE EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 6. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS C2.05 PLAN & PROFILE FUTURE 12" WATER LINE B. Ruch B. Ruch 1"=50' 12 FUTURE 12" WATER LINE PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' LINE MATCH STA 30+50 MATCH LINE SEE SHEET C2.06 STA 41+50 LINE MATCH STA 41+50 MATCH LINE STA SEE SHEET C2.04 30+50 C2.03 C2.04 C2.05 C2.06 C2.07 C2.08 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) T.O.P.=4894.93 STA. 24+68.21 12"x8" TEE T.O.P.=4895.30 STA. 25+11.10 22.5° BEND BEGIN HORZ. DEFL. T.O.P.=4896.96 STA. 29+45.52 12"x6" SWIVEL TEE T.O.P.=4897.10 STA. 26+25.00 12"x6" SWIVEL TEE T.O.P.=4898.69 75.0' DEF. STA. 25+11.07 T.O.P.=4896.96 STA. 25+86.07 T.O.P.=4898.84 (@ 0.9°) 75.0' DEF. STA. 24+36.07 T.O.P.=4894.93 STA. 25+11.07 T.O.P.=4896.96 (@ 0.8°) EXISTING GROUND PROPOSED GROUND TOP OF WATER PIPE PROPOSED GROUND 12" PVC 12" PVC STA. 22+76.3 0.1° DEFLECTION T.O.P.=4894.93 STA. 21+50.00 12"x6" SWIVEL TEE T.O.P.=4895.23 18" MIN. RESTRAIN ALL JOINTS STA.=26+48.5 STA.=27+13.1 12" PVC SANITARY STA.=25+37.33 INV.=4890.99 36" RCP STORM STA.=26+80.97 INV.=4897.98 E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO ST W FO FO FO FO FO FO FO E E E E E E E E E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 80' PERMANENT EASEMENT CDOT PROJ. IR 025-3(89) REC. NO. 88026808 134.48 LF 12" PVC S17°41'21"W 3 2 0 .52 L F 1 2 " PV C R = 59 0 .0 0 ' 113.90 LF 12" PVC R=590.00' SW FRONTAGE ROAD FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 STA.=20+15.52 END HORZ. DEFL. N: 122809.24 E: 214617.08 STA. 21+50.00 12"x6" SWIVEL TEE w/ 12" BFV (S), 6" GV (W), & FH ASSEMBLY N:122681.11 E:214576.22 STA.=25+11.10 22.5° BEND w/ TB, BEGIN HORZ. DEFL. N: 122337.09 E: 214466.50 STA.=26+25.00 12"x6" SWIVEL TEE w/ 12" BFV (S), & 6" GV (W) N: 122224.76 E: 214484.24 STA.=29+45.52 12"x6" SWIVEL TEE w/ 12" BFV (SE), & 6" GV (SW) N: 121950.77 E: 214642.87 28' EOP-EOP SANITARY LINE A SEE SHEET C2.10 CULVERT 1 SEE SHEET C2.20 CULVERT 2 SEE SHEET C2.20 277.13 LF 12" PVC S17°41'21"W 41.08 LF 12" PVC S17°41'21"W STA. 24+27.13 12" STUB w/ PLUG N:122417.09 E:214492.01 STA. 24+68.21 12"x8" TEE w/ TB, 8" GV (W), & 12" BFV (S) N:122377.95 E:214479.53 42.89 LF 12" PVC S17°41'21"W FH ASSEMBLY N:122687.69 E:214555.59 FH ASSEMBLY N:122215.11 E:214446.97 FH ASSEMBLY N:121923.25 E:214615.95 FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EXISTING LOTLINE EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 6. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS C2.04 PLAN & PROFILE FUTURE 12" WATER LINE B. Ruch B. Ruch 1"=50' 11 FUTURE 12" WATER LINE PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' LINE MATCH STA 20+50 MATCH LINE SEE SHEET C2.05 STA 30+50 LINE MATCH STA 30+50 MATCH LINE SEE SHEET C2.03 STA 20+50 C2.03 C2.04 C2.05 C2.06 C2.07 C2.08 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) T.O.P.=4898.19 STA. 18+16.33 BEGIN HORZ. DEFL. T.O.P.=4896.02 STA. 11+31.97 BEGIN HORZ. DEFL. T.O.P.=4897.03 STA. 20+15.52 END HORZ. DEFL. T.O.P.=4895.55 STA. 13+93.39 END HORZ. DEFL. T.O.P.=4892.14 100.0' DEF. STA. 12+52.95 T.O.P.=4896.43 STA. 13+52.95 T.O.P.=4894.00 (@ 0.6°) 100.0' DEF. STA. 15+84.47 T.O.P.=4893.54 STA. 16+84.47 T.O.P.=4896.33 (@ 0.7°) 100.0' DEF. STA. 13+71.36 T.O.P.=4893.10 STA. 14+71.36 T.O.P.=4890.62 (@ 0.5°) 100.0' DEF. STA. 14+83.70 T.O.P.=4890.61 STA. 15+83.70 T.O.P.=4893.49 (@ 0.7°) 18" MIN. 27" PVC WATER STA.=11+84.97 TOP=4897.73 30" PVC WATER STA.=11+93.75 TOP=4897.59 12" PVC SANITARY STA.=17+05.57 INV.=4888.53 FO FO FO E E E E W W W W W W W W SS SS SS SS SS SS SS SS SS G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO ST ST W E E E E E E E E E E E E E E E E E E E E E W W 2 550001_2550001 1 SA G G G G W OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W G G G G E E E E E SA W W W W W W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SS SS SS SS S S W W W W W W OWNER CITY OF FORT COLLINS OWNER CONVENIENCE RETAILERS LLC E PROSPECT RD 80' PERMANENT EASEMENT CDOT PROJ. IR 025-3(89) REC. NO. 88026808 APPROXIMATE LOCATION EXISTING 8" WATER LINE (ELCO) APPROXIMATE LOCATION 27" SANITARY SEWER (BOXELDER) ±36' ASPHALT ROAD APPROXIMATE LOCATION EXISTING 27" WATER LINE (GREELEY) 134.48 LF 12" PVC S17°41'21"W 120.76 LF 12" PVC S00°37'53"E 93.64 LF 12" PVC N89°22'07"E 20.50 LF 12" PVC N89°22'07"E 15.19 LF 12" PVC S00°37'53"E 172.86 LF 12" PVC S22°23'59"E 107.52 LF 12" PVC S01°38'36"W 24.46 LF 12" PVC S42°22'05"E 1 99. 1 9 L F 12 " P V C R = 62 2 . 96 ' 261.4 1 L F 12 " PV C R = 6 22 . 9 6 ' SW FRONTAGE ROAD APPROXIMATE LOCATION EXISTING 8" SANITARY (BOXELDER) FUTURE SANITARY LINE A2 SEE SHEET C2.14-C2.15 STA. 10+24.46 45.00° BEND w/ TB N:123662.61 E:214421.34 STA.=10+00.00 CUT IN 8"x12" TEE w/ TB 12" BFV (SE), & 8" GV (SW) N: 123680.68 E: 214404.86 STA.=13+93.39 END HORZ. DEFL. N: 123299.88 E: 214465.00 APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) STA.=11+31.97 BEGIN HORZ. DEFL. N: 123555.14 E: 214418.25 FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 STA. 15+66.25 22.50° BEND w/ TB N:123140.07 E:214530.87 STA. 15+81.44 90.00° BEND w/ TB N:123124.88 E:214531.04 STA. 16+01.93 12"x6" SWIVEL TEE w/ 12" BFV (E), 6" GV (N), & FH ASSEMBLY N:123125.10 E:214551.54 STA. 16+95.57 12"x12" TEE w/ TB, 12" BFV (S), 8" GV (E), & 12"x8" REDUCER (E) N:123126.14 E:214645.17 8" STUB w/ PLUG N:123126.22 E:214653.17 8.00 LF 8" PVC S89°22'07"W STA.=18+16.33 BEGIN HORZ. DEFL. N: 123005.39 E: 214646.50 STA.=20+15.52 END HORZ. DEFL. N: 122809.24 E: 214617.08 FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 FH ASSEMBLY N:122687.69 E:214555.59 FH ASSEMBLY N:123134.42 E:214551.43 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH C2.03 C2.04 C2.05 C2.06 C2.07 C2.08 ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EXISTING LOTLINE EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 6. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS C2.03 PLAN & PROFILE FUTURE 12" WATER LINE B. Ruch B. Ruch 1"=50' 10 FUTURE 12" WATER LINE PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' LINE MATCH STA 20+50 MATCH LINE SEE SHEET C2.04 STA 20+50 45° BEND T.O.P.=4894.47 STA. 38+22.8 45° BEND T.O.P.=4894.58 STA. 38+01.3 45° BEND T.O.P.=4890.81 STA. 38+19.0 45° BEND T.O.P.=4890.81 STA. 43+98.88 12" STUB w/ PLUG T.O.P.=4893.45 STA. 34+64.34 BEGIN HORZ. DEFL. T.O.P.=4894.47 STA. 42+59.13 END HORZ. DEFL. T.O.P.=4896.31 STA. 39+05.52 12"x6" SWIVEL TEE T.O.P.=4894.94 STA. 42+49.13 12"x6" SWIVEL TEE T.O.P.=4896.37 100.0' DEF. STA. 42+27.34 T.O.P.=4896.37 STA. 43+27.35 T.O.P.=4894.89 (@ 0.4°) 100.0' DEF. STA. 35+71.82 T.O.P.=4893.93 STA. 36+71.82 T.O.P.=4893.91 (@ 0.1°) 71.5' DEF. STA. 43+27.35 T.O.P.=4894.89 STA. 43+98.88 T.O.P.=4893.45 (@ 0.5°) EXISTING GROUND PROPOSED GROUND TOP OF WATER PIPE PROPOSED GROUND FUTURE 12" PVC 36" RCP STORM STA.=38+14.04 INV.=4892.68 36" RCP STORM STA.=38+06.28 INV.=4892.64 18" MIN. RESTRAIN ALL JOINTS STA.=37+72.6 STA.=38+47.8 W W W W W W W W W W W W W W G FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E OHE OHE OHE OHE OHE OHE W W W W W FO FO FO FO FO FO FO FO FO FO FO FO FO OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE FO FO FO FO FO OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE / / / / / / / / / / / / / / / / X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / VAULT ELEC / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) 44 1 . 1 8 L F 1 2 " P V C R =6 1 0. 00 ' 3 4 3 . 61 L F 12 " P V C R = 61 0 . 0 0 ' 10.00 LF 12" PVC R=610.00' SW FRONTAGE ROAD SANITARY LINE B SEE SHEET C2.11 STA.=34+64.34 BEGIN HORZ. DEFL. N: 121759.08 E: 215114.69 84' ROW 28' EOP-EOP STA.=39+05.52 12"x6" SWIVEL TEE w/ 12" BFV (SE), & 6" GV (SW) N: 121530.31 E: 215480.70 STA.=42+49.13 12"x6" SWIVEL TEE w/ 12" BFV (S), & 6" GV (W) N: 121214.03 E: 215602.97 STA.=42+59.13 END HORZ. DEFL. N: 121204.06 E: 215603.76 INTERSTATE 25 SW FRONTAGE ROAD FUTURE 15' UTILITY EASEMENT CULVERT 3 SEE SHEET C2.20 STA. 43+98.88 12" STUB w/ PLUG N:121064.66 E:215613.65 FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC WATER FH ASSEMBLY N:121506.99 E:215450.06 FH ASSEMBLY N:121210.68 E:215564.62 FUTURE SANITARY LINE B SEE SHEET C2.16-C2.18 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 EXISTING SW FRONTAGE ROAD FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EXISTING LOTLINE EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 6. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS C2.02 PLAN & PROFILE 12" WATER LINE B. Ruch B. Ruch 1"=50' 9 12" WATER LINE PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' MATCH LINE SEE SHEET C2.01 STA 34+50 C2.01 C2.02 LINE MATCH STA 34+50 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) 4903.61 4903.48 4903.23 4903.10 4902.97 4902.72 4902.59 4902.46 4902.21 4902.08 4901.95 4901.70 4901.57 4901.45 4901.19 4901.07 4900.94 4900.68 4900.56 4900.43 4900.18 4900.05 4899.93 4899.68 12" PVC 12" PVC 12" PVC STA. 33+27.4 45° BEND T.O.P.=4892.22 STA. 33+37.4 45° BEND T.O.P.=4892.22 STA. 33+40.3 45° BEND T.O.P.=4895.08 STA. 26+73.5 45° BEND T.O.P.=4898.49 STA. 26+75.8 45° BEND T.O.P.=4896.15 STA. 26+85.8 45° BEND T.O.P.=4896.15 STA. 26+88.1 45° BEND T.O.P.=4898.41 STA. 33+24.5 45° BEND T.O.P.=4895.16 75.0' DEF. STA. 25+11.07 T.O.P.=4896.96 STA. 25+86.07 T.O.P.=4898.84 (@ 0.9°) 75.0' DEF. STA. 24+36.07 T.O.P.=4894.93 STA. 25+11.07 T.O.P.=4896.96 (@ 0.8°) EXISTING GROUND PROPOSED GROUND TOP OF WATER PIPE PROPOSED GROUND FUTURE 12" PVC 12" PVC SANITARY STA.=33+32.44 INV.=4893.74 12" PVC SANITARY STA.=25+37.33 INV.=4890.99 36" RCP STORM STA.=26+80.97 INV.=4897.98 18" MIN. 18" MIN. RESTRAIN ALL JOINTS STA.=26+48.5 STA.=27+13.1 RESTRAIN ALL JOINTS STA.=32+99.5 STA.=33+65.3 E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO ST W FO FO FO FO FO FO FO FO E E E E E E / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / M / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 58.82 LF 12" PVC S78°42'43"E 340.63 LF 12" PVC 320.52 LF 12" PVC R=590.00' R=590.00' 113.90 LF 12" PVC R=590.00' SW FRONTAGE ROAD SW FRONTAGE ROAD SANITARY LINE A SEE SHEET C2.10 SANITARY LINE A2 SEE SHEET C2.10 STA.=25+11.10 22.5° BEND w/ TB, BEGIN HORZ. DEFL. N: 122337.09 E: 214466.50 STA.=26+25.00 12"x6" SWIVEL TEE w/ 12" BFV (S), & 6" GV (W) N: 122224.76 E: 214484.24 STA.=29+45.52 12"x6" SWIVEL TEE w/ 12" BFV (SE), & 6" GV (SW) N: 121950.77 E: 214642.87 28' EOP-EOP STA.=32+86.15 END HORZ. DEFL. N: 121793.96 E: 214939.95 STA.=34+64.34 BEGIN HORZ. DEFL. N: 121759.08 E: 215114.69 CULVERT 1 SEE SHEET C2.20 CULVERT 2 SEE SHEET C2.20 STA. 24+27.13 12" STUB w/ PLUG N:122417.09 E:214492.01 FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC WATER 100.00 LF 8" PVC S72°18'39"E STA. 24+68.21 12"x8" TEE w/ TB, 12" BFV (S), & 8" GV (W) N:122377.95 E:214479.53 42.89 LF 12" PVC S17°41'21"W 8" STUB w/ PLUG N:122408.33 E:214384.26 FUTURE 15' UTILITY EASEMENT FUTURE 12" PVC SANITARY SEWER FH ASSEMBLY N:122215.11 E:214446.97 FH ASSEMBLY N:121923.25 E:214615.95 FH ASSEMBLY N:121732.84 E:215049.47 28.94 LF 8" PVC S20°57'59"W 18.47 LF 8" PVC S11°17'17"W 26.14 LF 8" PVC S11°17'17"W 41.45 LF 8" PVC S20°57'59"W 11.25° BEND w/ TB N:121756.66 E:214993.26 8" STUB w/ PLUG N:121717.96 E:214978.43 FUTURE 12" PVC SANITARY SEWER 11.25° BEND w/ TB N:121800.41 E:215001.99 8" STUB w/ PLUG N:121827.43 E:215012.35 STA. 33+45.74 12"x8" CROSS w/ 12" BFV (E), & 2-8" GV (N,S) N:121782.30 E:214998.38 59.79 LF 12" PVC S78°42'43"E STA.=34+05.52 12"x6" SWIVEL TEE w/ 6" GV (S) N: 121770.59 E: 215057.01 59.58 LF 12" PVC S78°42'43"E FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 FUTURE SANITARY LINE A2 SEE SHEET C2.14-C2.15 FUTURE 15' UTILITY EASEMENT No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 50 0 50 Feet 50 100 150 Reviewed EAST By: LARIMER General COUNTY Manager WATER DISTRICT Date UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D EXISTING LOTLINE EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND TOWN SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 6. PIPE LENGTH LABELS SHOWN IN PLAN VIEW DENOTE THE HORIZONTAL DISTANCE BETWEEN HORIZONTAL FITTINGS, AND DO NOT ACCOUNT FOR VERTICAL BENDS OR DEFLECTIONS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS C2.01 PLAN & PROFILE 12" WATER LINE B. Ruch B. Ruch 1"=50' 8 12" WATER LINE PROFILE SCALE: VERT. 1"=5' HORIZ. 1"=50' MATCH LINE SEE SHEET C2.02 STA 34+50 LINE MATCH STA 34+50 C2.01 C2.02 84' ROW (BY SEPARATE DOCUMENT REC. NO. _______________) X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / F E S LID LID LID M CO CO CO COCOCOCO CO CO CO COCO CO CO CO CO M SS SS SS SS SS SS S S S S S SS SS SS SS S S S VAULT ELEC E E E W W W W W W W W W FO E E E E E E E E E E E G G G FO FO FO FO FO FO E E OHE OHE OHE OHE OHE OHE W W W FO E E G G G W W W W W W W W W W W W W W W W SS 8" Concreted PVC Pipe SA SS G FO FO FO E E E E FO FO FO E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO T SA OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W W W FO FO E E E E E FO FO FO FO FO SA SA E E W 2550002_1 W W W W 2550001_1 2550002 2550001 SA G G SA SA SA FO ST OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W W W W W W G G G G G G G G G G G G G E E SA W W W W W W W W W W W G 8" Concreted PVC Pipe SA FO FO FO FO FO FO FO F F F F W W W W W W W W W W W W W W W W W W W W W W W o W W W W W W o o o W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G SS SS SS W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / FUTURE SANITARY LINE A2 SEE SHEET C2.14-C2.15 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 EXISTING 18" ADS CULVERT E PROSPECT RD APPROXIMATE LOCATION EXISTING 27" WATER LINE (GREELEY) APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) APPROXIMATE LOCATION EXISTING 8" WATER LINE (ELCO) APPROXIMATE LOCATION EXISTING 27" SANITARY SEWER (BOXELDER) APPROXIMATE LOCATION EXISTING HIGH PRESSURE GAS LINE APPROXIMATE LOCATION EXISTING 8" WATER LINE (ELCO) APPROXIMATE LOCATION EXISTING 2 1/2" WATER LINE (ELCO) EXISTING CDOT STORM DRAIN APPROXIMATE LOCATION EXISTING 8" SANITARY SEWER (BOXELDER) APPROXIMATE LOCATION 18" SANITARY SEWER (BOXELDER) EXISTING 48" CMP CULVERT EXISTING 18" CMP CULVERT APPROXIMATE LOCATION 30" WATER LINE (GREELEY) SW FRONTAGE ROAD E PROSPECT RD INTERSTATE 25 INTERSTATE 25 REST AREA ACCESS RD APPROXIMATE LOCATION EXISTING 2 1/2" WATER LINE (ELCO) APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) APPROXIMATE LOCATION EXISTING 30" SANITARY SEWER (BOXELDER) EXISTING WATER LINE SANITARY LINE A SEE SHEET C2.10 FUTURE SANITARY LINE B SEE SHEET C2.16-C2.18 FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC WATER FUTURE FH FUTURE FH FUTURE FH FUTURE FH FUTURE CONNECT TO 2 1/2" ELCO WATER LINE FUTURE FH FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC SANITARY SEWER SANITARY LINE A2 SEE SHEET C2.10 SANITARY LINE B SEE SHEET C2.11 PROPOSED FH PROPOSED FH PROPOSED FH PROPOSED FH PROPOSED FH PROPOSED 8" WATER STUB PROPOSED 12" WATER STUB FUTURE 12" PVC SANITARY SEWER FUTURE 12" PVC WATER PROPOSED 12" SANITARY STUB CULVERT 1 SEE SHEET C2.20 CULVERT 2 SEE SHEET C2.20 CULVERT 3 SEE SHEET C2.20 PROPOSED 8" WATER STUB PROPOSED 12" SANITARY STUB PROPOSED 12" SANITARY STUB PROPOSED 8" WATER STUB PROPOSED 12" WATER STUB PROPOSED 12" SANITARY STUB 12" WATER LINE SEE SHEET C2.01-C2.02 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 FUTURE SANITARY LINE A SEE SHEET C2.12-C2.13 FUTURE 12" WATER LINE SEE SHEET C2.03-C2.08 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 250 0 250 Feet 250 500 750 C2.00 OVERALL UTILITY PLAN B. Ruch M. Kuehnel 1"=250' 7 EXISTING WATER MAIN PROPOSED WATER MAIN PROPOSED STORM SEWER LEGEND: W G T E EXISTING STORM SEWER EXISTING ELECTRIC EXISTING TELEPHONE EXISTING GAS EXISTING ELECTRIC METER EXISTING WATER METER EXISTING IRRIGATION BOX EXISTING POWER POLE EXISTING GAS METER EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT H Y D PROPOSED ROW EASEMENT LINE W CONTROL IRR W S O E G PROPERTY BOUNDARY NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER CONSTRUCTION SHALL BE PER THE ELCO WATER DISTRICT SPECIFICATIONS LATEST EDITION. 3. ALL SEWER CONSTRUCTION SHALL BE PER THE BOXELDER SANITATION DISTRICT SPECIFICATIONS LATEST EDITION. 4. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS AND SERVICES. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH TOWN STREET REPAIR STANDARDS. 7. ALL WATERLINES SHALL HAVE A MINIMUM COVER OF 4.5' AND MAXIMUM COVER OF 5.5' FROM FINISHED GRADE TO TOP OF PIPE UNLESS OTHERWISE NOTED. INTERSTATE ACCESS EXISTING LOTLINE No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 SS SS SS SS SS SS SS SS SS SS S S S SS OWNER CITY OF FORT COLLINS OWNER BOXELDER SANITATION DISTRICT OWNER CITY OF FORT COLLINS OWNER BOXELDER SANITATION DISTRICT OWNER BOXELDER SANITATION DISTRICT OWNER CITY OF FORT COLLINS OWNER VAN DYK/VOS LLC EXISTING LARGE STORAGE STRUCTURE EXISTING 4.5' CONCRETE IRRIGATION DITCH EXISTING 16' DIRT DITCH EXISTING 18" RCP w/ FES EXISTING 2"x6" WOOD RETAINING WALL EXISTING FOOT BRIDGE 60'UTILITY & ACCESS EASEMENT #2 REC. NO. 95055231 EXISTING CATTLE GUARD 20' WATERLINE EASEMENT BK. 2188, PG. 685 1982 SIGN "CITY OF GREELEY BURIED PIPELINE" 5' Ø STEEL LID EXISTING FENCE INTERSTATE 25 APPROXIMATE LOCATION EXISTING 2 1/2" WATER LINE (ELCO) APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) ±23' GRAVEL ROAD APPROXIMATE LOCATION EXISTING 30" SANITARY SEWER (BOXELDER) EXISTING WATER LINE ±11' GRAVEL ROAD APPROXIMATE LOCATION EXISTING 2 1/2" WATER LINE (ELCO) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN LEGEND: FIELD SURVEY BY: NOTES: ORIGINAL FIELD SURVEY KIND SURVEYORS, INC. PROJECT NO. 2007390 DATE: OCTOBER 19, 2007 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, SIDEWALKS, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 3. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 5. ALL SURVEY INFORMATION TAKEN FROM THE ALTA/ACSM LAND TITLE SURVEY PRODUCED BY KING SURVEYORS, INC. DATED 11/01/07. EXISTING EDGE OF WATER EXISTING EDGE OF ASPHALT EXISTING EDGE OF GRAVEL EXISTING FLOWLINE EXISTING OVERHEAD ELECTRIC EXISTING ROAD CENTER LINE EXISTING FENCE X PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 / / / / / / / / / / / / / / / / EXISTING CLEAN OUT EXISTING REFLECTOR POST EXISTING TRAFFIC MAST EXISTING SIGN EXISTING SANITARY MANHOLE EXISTING FIRE HYDRANT ALIQUOT CORNER H Y EXISTING LIGHT POLE EXISTING EASEMENT EXISTING SECTION LINE CO INTERSTATE ACCESS C1.02 & DEMOLITION PLAN EXISTING CONDITIONS C. Snowdon M. Kuehnel 1"=100' 6 MATCH LINE-SEE SHEET C1.02 C1.00 C1.01 C1.02 ( IN FEET ) 1 inch = ft. 100 0 100 Feet 100 200 300 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 FO T ST ST ST OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE FO FO FO FO FO FO FO FO FO FO G G OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / CO CO COCOCOCO CO CO CO CO CO COCO CO CO CO VAULT ELEC OWNER VAN DYK/VOS LLC OWNER CITY OF FORT COLLINS OWNER CITY OF FORT COLLINS OWNER ABC LAND CORPORATION LLC OWNER J-B INVESTMENTS INC OWNER COMMERCIAL NET LEASE REALTY INC NATIONAL RETAIL PROPERTIES INC OWNER MAXEY-URBEN-MAXEY LLC EXISTING 3.5' CONCRETE IRRIGATION DITCH EXISTING 4.5' CONCRETE IRRIGATION DITCH EXISTING 3.5' CONCRETE IRRIGATION DITCH 20' WATERLINE EASEMENT BK. 2188, PG. 685 1982 EXISTING LARGE OVERHEAD ELECTRIC TRANSMISSION LINES EXISTING FOOT BRIDGE METAL SHED EXISTING GARAGE HOUSE HOUSE WOOD SHED 50' WATERLINE EASEMENT BK. 601 PG. 42 1929 CAT TAILS EXISTING 12" STEEL CULVERT EXISTING 30" CMP CULVERT 10' GRAVEL ROAD OFFICE BUILDING SILO SILO EXISTING FOOT BRIDGE EXISTING 4.5' CONCRETE IRRIGATION DITCH EXISTING 12' GRAVEL DRIVE EXISTING 48" CMP EXISTING 18" CMP EXISTING 16' DIRT DITCH 0.5' TIMBER WALL BRIDGE EXISTING GATE EXISTING GRAVEL DRIVEWAY EXISTING FENCE INTERSTATE 25 APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) APPROXIMATE LOCATION EXISTING 27" WATER LINE (GREELEY) APPROXIMATE LOCATION EXISTING 2 1/2" WATER LINE (ELCO) ±20' ASPHALT ROAD APPROXIMATE LOCATION EXISTING PRPA VAULT EXISTING 3.5' CONCRETE IRRIGATION DITCH TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING 4.5' CONCRETE IRRIGATION DITCH TO BE REMOVED EXISTING 4.5' CONCRETE IRRIGATION DITCH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN LEGEND: FIELD SURVEY BY: NOTES: ORIGINAL FIELD SURVEY KIND SURVEYORS, INC. PROJECT NO. 2007390 DATE: OCTOBER 19, 2007 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, SIDEWALKS, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 3. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 5. ALL SURVEY INFORMATION TAKEN FROM THE ALTA/ACSM LAND TITLE SURVEY PRODUCED BY KING SURVEYORS, INC. DATED 11/01/07. EXISTING EDGE OF WATER EXISTING EDGE OF ASPHALT EXISTING EDGE OF GRAVEL EXISTING FLOWLINE EXISTING OVERHEAD ELECTRIC EXISTING ROAD CENTER LINE EXISTING FENCE X PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 / / / / / / / / / / / / / / / / EXISTING CLEAN OUT EXISTING REFLECTOR POST EXISTING TRAFFIC MAST EXISTING SIGN EXISTING SANITARY MANHOLE EXISTING FIRE HYDRANT ALIQUOT CORNER H Y EXISTING LIGHT POLE EXISTING EASEMENT EXISTING SECTION LINE CO INTERSTATE ACCESS MATCH LINE-SEE SHEET C1.00 C1.01 & DEMOLITION PLAN EXISTING CONDITIONS C. Snowdon M. Kuehnel 1"=100' 5 MATCH LINE-SEE SHEET C1.02 C1.00 C1.01 C1.02 ( IN FEET ) 1 inch = ft. 100 0 100 Feet 100 200 300 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 W E E E E E E E E E W G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W SS SS ST 8" Concreted PVC Pipe SA SS SS SS G G G G G G FO FO FO FO FO FO E E E E E E E E E E E FO FO FO FO FO E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO E FO FO FO FO FO FO FO SA ST ST OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W W W FO FO FO FO FO E E E E E E E E E E E E FO FO FO FO SA SA E W W W W W W 2550002_1 W W W W W W W W W W W W W 2550001_1 2550002 2550001 SA SS SS SS SS E E G G G G G E E E E SA SA SA FO FO FO FO ST ST OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W W E G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G E E E E E SA W W W W W W W W W W W W W W W W W W W W W W W G G G 8" Concreted PVC Pipe SA SS FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO FO / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / F E S L ID LID LID M SS SS SS SS SS SS SS S S OWNER DEPARTMENT OF TRANSPORTATION STATE OF COLORADO OWNER BOARD OF AG FOR THE USE AND BENEFIT OF COLORADO OWNER CITY OF FORT COLLINS OWNER MAXEY-URBEN-MAXEY LLC OWNER PROSPECT PROPERTY LLC OWNER HFH LLC OWNER PARADIGM PROPERTIES LLC OWNER PARADIGM PROPERTIES LLC OWNER CW SUBTRUST (.348249) WHITE ERIC S (.175943) OWNER PROSPECT PROPERTY LLC (.50) DINGS ANN M LIVING TRUST (.50) OWNER CITY OF FORT COLLINS OWNER FORT COLLINS/I-25 INTERCHANGE CORNER LLC OWNER FORT COLLINS/I-25 INTERCHANGE CORNER LLC OWNER THE SMITH JOAN W TRUST CSB INVEST LLC / KZ SMITH FAMILY LLC OWNER CONVENIENCE RETAILERS LLC OWNER SMITH LEROY K EXISTING FENCE EXISTING SLUDGE PUMP EXISTING GATE TO BE REMOVED EXISTING ABANDONED GRAVEL ROAD EXISTING 4.5' CONCRETE IRRIGATION DITCH EXISTING GATE 20' SEWER EASEMENT BK. 1958 PG. 541 1979 20' SEWER EASEMENT BK. 1958 PG. 535 1979 80' PERMANENT EASEMENT CDOT PROJ. IR 025-3(89) REC. NO. 88026808 80' PERMANENT EASEMENT CDOT PROJ. IR 025-3(89) REC. NO. 88026808 EXISTING 8.0' CONCRETE IRRIGATION DITCH EXISTING 12' DIRT ROAD TO BE REMOVED EXISTING 5.5' CONCRETE IRRIGATION DITCH EXISTING 4.5' CONCRETE IRRIGATION DITCH EXISTING GATE TO BE REMOVED EXISTING GATE TO BE REMOVED EXISTING 3.5' CONCRETE IRRIGATION DITCH EXISTING 4.5' CONCRETE IRRIGATION DITCH EXISTING 18" ADS CULVERT EXISTING 4.5' CONCRETE IRRIGATION DITCH EXISTING 8" CONCRETE WINGWALL w/ METAL HANDRAIL 30' WATERLINE EASEMENT BK. 2188, PG. 685 1982 SW FRONTAGE RD E PROSPECT RD INTERSTATE 25 REST AREA ACCESS RD APPROXIMATE LOCATION EXISTING 27" WATER LINE (GREELEY) APPROXIMATE LOCATION EXISTING 30" WATER LINE (GREELEY) APPROXIMATE LOCATION EXISTING 8" WATER LINE (ELCO) APPROXIMATE LOCATION 27" SANITARY SEWER (BOXELDER) APPROXIMATE LOCATION EXISTING HIGH PRESSURE GAS LINE EXISTING FENCES TO BE REMOVED APPROXIMATE LOCATION EXISTING 8" WATER LINE (ELCO) APPROXIMATE LOCATION EXISTING 2 1/2" WATER LINE (ELCO) ±36' ASPHALT ROAD ±29' ASPHALT ROAD TO BE REMOVED CDOT STORM DRAIN APPROXIMATE LOCATION EXISTING 8" SANITARY SEWER (BOXELDER) APPROXIMATE LOCATION 18" SANITARY SEWER (BOXELDER) EXISTING CULVERT TO BE REMOVED EXISTING PIPE TO BE REMOVED / / / / / / / / / / / / / EXISTING 5.5' CONCRETE IRRIGATION DITCH TO BE REMOVED CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner NORTH ( IN FEET ) 1 inch = ft. 100 0 100 Feet 100 200 300 KEYMAP F E S M VAULT ELEC INTERSTATE 25 PROSPECT ROAD MCLAUGHLIN LN C1.00 & DEMOLITION PLAN EXISTING CONDITIONS C. Snowdon M. Kuehnel 1"=100' 4 MATCH LINE-SEE SHEET C1.01 C1.00 C1.01 C1.02 LEGEND: FIELD SURVEY BY: NOTES: ORIGINAL FIELD SURVEY KIND SURVEYORS, INC. PROJECT NO. 2007390 DATE: OCTOBER 19, 2007 1. EXISTING UNDERGROUND AND OVERHEAD PUBLIC AND PRIVATE UTILITIES AS SHOWN ARE INDICATED ACCORDING TO THE BEST INFORMATION AVAILABLE TO THE ENGINEER. THE ENGINEER DOES NOT GUARANTEE THE ACCURACY OF SUCH INFORMATION. EXISTING UTILITY MAINS AND SERVICES MAY NOT BE STRAIGHT LINES OR AS INDICATED ON THESE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CALL ALL UTILITY COMPANIES (PUBLIC AND PRIVATE) PRIOR TO ANY CONSTRUCTION TO VERIFY EXACT UTILITY LOCATIONS. 2. THE CONTRACTOR SHALL PROTECT ALL EXISTING FEATURES THAT ARE NOT TO BE REMOVED ADJACENT TO THE CONSTRUCTION AREA INCLUDING, BUT NOT LIMITED TO, SIDEWALKS, PRIVATE FENCES, ABOVE GROUND OR UNDERGROUND UTILITIES, STRUCTURES, AND UNDERGROUND FOUNDATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE THAT SHOULD OCCUR TO ANY ON-SITE, OFF-SITE, PUBLIC OR PRIVATE FACILITY OR FEATURE AS A RESULT OF THE CONSTRUCTION PROCESS FOR THIS PROJECT. 3. LIMITS OF STREET CUT AS REQUIRED FOR UTILITY CONSTRUCTION ARE TO BE DETERMINED IN THE FIELD BY THE TOWN ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONTRACTOR SHALL COORDINATE ALL CONSTRUCTION ITEMS IMPACTING ADJACENT PROPERTIES WITH THE PROPERTY OWNERS PRIOR TO BEGINNING ANY CONSTRUCTION ACTIVITIES. 3. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 5. ALL SURVEY INFORMATION TAKEN FROM THE ALTA/ACSM LAND TITLE SURVEY PRODUCED BY KING SURVEYORS, INC. DATED 11/01/07. EXISTING EDGE OF WATER EXISTING EDGE OF ASPHALT EXISTING EDGE OF GRAVEL EXISTING FLOWLINE EXISTING OVERHEAD ELECTRIC EXISTING ROAD CENTER LINE EXISTING FENCE X PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 / / / / / / / / / / / / / / / / EXISTING CLEAN OUT EXISTING REFLECTOR POST EXISTING TRAFFIC MAST EXISTING SIGN EXISTING SANITARY MANHOLE EXISTING FIRE HYDRANT ALIQUOT CORNER H Y EXISTING LIGHT POLE EXISTING EASEMENT EXISTING SECTION LINE CO INTERSTATE ACCESS No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C0.02 & TYPICAL ROADWAY SECTION ELCO & BOXELDER GENERAL NOTES B. Ruch M. Kuehnel N/A 3 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT General Manager Date EAST LARIMER COUNTY WATER DISTRICT UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} F. BOXELDER GENERAL NOTES 1. Existing Utility Locates: It shall be the responsibility of the Contractor to coordinate field locates of all existing utilities prior to commencement of any construction. Contractor shall also notify all affected utility companies prior to commencing construction. In the event of damage to any existing utility, the contractor shall immediately notify the owner of the utility involved and unless authorized in writing by the owner of the subject utility, shall not attempt to make repairs. The cost of repairs shall be the responsibility of the Contractor. 2. District Owned Easement Pictures: Contractor to provide sequential digital pictures spaced at no more than 300 feet detailing conditions of the off-site Boxelder Owned Easement Conditions and any structures that could be affected, to the District and the property owner prior to the start of any off-site work. These pictures shall include all existing fence, ditches, ditch structures, out buildings, water troughs, trees and all other landscaping. Pictures are to be placed at no more than four (4) pictures on a 11x8 sheet of photo paper inserted into transparent sleeves and delivered with the drawings of record in a three (3) ring binder. 3. Protection of Property: Contractor shall continuously maintain adequate protection from damage of all public and private property through which the work is done. 4. Safety: All sewer main installation within the District shall be subject to current (Occupational Safety and Heath Association (OSHA) and the Colorado Safety Association, (CSA) safety requirements. Contractor shall also comply with any and all requirements and regulations as set forth by City, County, State and Federal agencies having applicable authority. 5. Start of Construction: No construction shall begin without prior design review of the District. The District shall be notified 48 hours in advance of starting construction or testing to allow for scheduling. 6. Road Excavation Permits: In event that State, County or City road excavation permit(s) are required, the Contractor is responsible for obtaining all road permits which may be required. 7. Other Permits: The Contractor shall be responsible for obtaining all permits required for construction. 8. Revisions: No verbal authorization for field revision shall be given. All requests for field revision shall be made in writing accompanied by proposed change indicated on copy of the approved design drawings. Any field revision approved and installed shall also be accurately documented on the Drawings of Record. 9. Materials: Plastic Pipe -All gravity sanitary sewer piping shall be Polyvinyl Chloride (PVC) unless otherwise noted on the approved drawings. Pipe 15” and smaller shall conform to ASTM D3034, Type PSM, and SDR 35. Pipe 18” and larger shall conform to ASTM F679. All fittings shall be (PVC) unless otherwise noted. 10. Pipe Cover: A minimum cover of 3-1/2 feet of cover shall be maintained throughout the sewer line and service line installation. 11. Bedding: All sewer main installation shall include bedding. Bedding shall be ¾” washed rock uniformly graded and compacted. Refer to force main desgin for force main bedding requirements. Trench shall be excavated to a depth below established grade equal to ¼ of pipe diameter (min. 4”). Bell depressions shall be provided for all joints. In event that unstable trench conditions are encountered at pipeline grade 1-1/2” uniformly graded washed rock shall be used for stabilization. Bedding material shall be placed and compacted under and around sides of the pipe. Place bedding in such a manner as to provide solid, uniform bearing surface for full length of barrel. Minimum 30” initial lift above pipe before other than hand compaction equipment is to be used. Note maximum trench width detail. 12. Backfill: Backfilling of trench shall be performed as soon as practical, subsequent to inspection and approval. Backfilling of acceptable material shall not be placed in lifts of greater than one (1) foot. Backfill shall be compacted to 95% of optimum density in roadway and residential areas and 90% in all off-site easement areas unless otherwise noted. Compaction testing of bedding and back fill shall be at least five tests per 1,000 feet and at varying depths and locations in accordance with the requirements of the applicable authority or as required in project specific specifications. 13. Concrete: All concrete construction shall be completed utilizing 3,000 psi at twenty-eight (28) days or equal concrete. 14. Pavement or Other Repairs: In event that asphalt or concrete pavement, sidewalks, storm sewers, waterline or any other public or privately owned property is damaged or requires reconstruction due to the work, repairs or replacement will be made in accordance with the requirements of the appropriate governing authority. Private property will be returned to its original condition or as close to original condition as reasonably possible, unless otherwise noted on the drawings. 15. Service Taps on Existing Lines: All taps made on existing lines shall be completed at developer's expense by District personnel or the District's authorized contractor with no exception. 16. Inspection: Construction shall conform to District Standards and Specifications or project specific specifications at all times. The District shall inspect the construction as necessary and shall observe all line testing. The District shall have the authority to ascertain that all construction of facilities is equal to or better than minimum construction requirements as set forth in 17. Testing: All lines shall be pressure tested and flushed by the Contractor in accordance with District Standards and Specifications and under the District's supervision. Upon passing, copies of all passing test results including soils compaction in the area of sewer main construction shall be provided to the District. 18. Acceptance: Upon completion of all utility construction (sewer and other) and fulfillment of all District requirements, preliminary acceptance of new sewer system improvements will occur in accordance with District's acceptance procedure. 19. Warranty: The Contractor shall warrant the materials, installation, workmanship and surface restoration for a period of two years from date of preliminary acceptance. During this warranty period the Developer shall promptly repair any defects in the work and maintain the work area. At the close of the two-year warranty period the District will make a field inspection. Upon satisfactory correction of any deficiencies noted the District would make final acceptance of the lines and work. The lines and the appurtenances shall then become the sole property and responsibility of Boxelder Sanitation District. 20. Drawings of Record and Total Costs: Within 90 days of preliminary acceptance of the new facilities, the District shall be provided with acceptable Drawings of Record of the complete system consisting of two sets of fill size reproduced prints, two sets of ½-size reproduced prints, one set of 6 mil double matted reproducible mylars and one complete digital file equivalent (software and version to be confirmed at time of delivery). Written confirmation of the total cost of all sewer system improvements shall also be submitted with the Drawings of Record. E. EAST LARIMER COUNTY WATER DISTRICT TYPICAL SECTIONS GENERAL NOTES FOR CONSTRUCTION Version: 10/10/2017 The following information is condensed from the current "Standard Construction Specifications for Water Mains" (Specification) as adopted by the East Larimer County Water District (‘ELCO’ or ‘District’) and is to be considered as such. In the event of any conflict the full District Specification document shall take precedence over these general notes. 1. Standards and Specifications: Construction shall be per the District Specifications in effect at the start of construction. Material or equipment shall be manufactured per the most recent version of applicable industry standards 2. Locates: Contractor shall coordinate field locates of all existing utilities prior to commencement of any construction and as required notify all affected utility companies prior to commencing construction. Cost of repairs to any other utility damaged during District waterline installation shall be the responsibility of the Contractor. 3. Damage to Property: Contractor shall continuously maintain adequate protection from damage of all public and private property through which the work is done and shall be fully responsible for all costs associated with damage to any and all other public and private property. 4. Safety: Contractor shall comply with any and all requirements and regulations as set forth by City, County, State and Federal agencies having applicable authority. 5. Landscaping Adjacent to District Waterlines: No landscaping (bushes, shrubs, trees or other plantings) that has a mature height of over 3 feet (3-ft) shall be placed within ten feet (10-ft) of any District waterline or appurtenance (distribution main, service line, fire hydrant, meter, etc.). Bushes or shrubs with a mature height of less than 3-ft shall be placed a minimum 4-ft from any District waterline or appurtenance. The District shall have the right to remove any landscaping that violates this standard, at any time such landscaping is discovered, and shall not be required to replace the removed landscaping. 6. Design Approval and Construction Start: No construction shall begin without prior design approval from ELCO. District shall be notified 48 hours in advance of starting construction or testing to allow for scheduling. 7. Permits: Contractor is responsible for obtaining all County road permits which may be required. For any permitting where the District must apply for a permit the Contractor shall coordinate, cover the cost and schedule the permit acquisition with the District. 8. Changes During Construction: No verbal authorization for field revision shall be given. All requests for such field revision shall be made in writing accompanied by proposed change indicated on copy of the approved design drawings. Any field revision approved and installed shall also be accurately documented on the Contrctor’s As-Built drawings. 9. Materials of Construction: a. Pipe: All water piping shall be Polyvinyl Chloride (PVC). All PVC piping 6-inch through 12-inch shall be DR 18 (pressure class 235 psi) and manufactured in accordance with AWWA Standard C900, "Polyvinyl Chloride (PVC) Pressure Pipe, 4-inch through 12-inch, For Water Distribution". All PVC piping 14-inch through 24-inch shall be DR 18 (pressure class 235 psi) and manufactured in accordance with AWWA Standard C905, "Polyvinyl Chloride (PVC) Water Transmission Pipe, Nominal Diameters 14-inch through 36". Pipe with a diameter greater than 24 inches shall be specified based on engineered design. b. Tracer Wire: All water piping shall be installed with a twelve (12) gauge solid copper wire, plastic coated, six hundred (600) volt taped to top of pipe and surfaced at each valve as a tracer wire. c. Pipe Joints: Pipe joints shall be made using an integral bell with an elastomeric gasket push-on type joint or using machined couplings of a sleeve type with rubber ring gaskets and machined pipe ends to form a push-on type joint. d. Materials and Installation: All materials installed shall be free of manufacturer defects. Any defective or damaged materials noted on the construction site shall be so marked and removed from the site. Under no circumstances shall any PVC piping be installed utilizing mechanical equipment to seat the joints. e. Pipe Fittings: All fittings shall be mechanical joint, ductile iron, manufactured in accordance with AWWA Standard C153. Fittings shall be furnished with a cement-mortar lining of standard thickness class with a 250 psi pressure rating. f. Gate Valves: Gate valves shall conform to AWWA Standard C509 with mechanical joint, 2" open left operating nut and resilient seat. g. Butterfly Valves: Butterfly valves shall be used for all valves 12-inches and larger and conform to AWWA Standard C504 with mechanical joint, 2" open left operating nut, resilient seat and shall be equipped with sand bonnet. h. Fire Hydrants: Hydrants shall conform to AWWA Standard C502, 1" square open-right operating nut. Allowable manufacturers and models are Mueller Super Centurion with epoxy coated shoe or American Flo Control Waterous Pacer WB-67-250X with epoxy coated shoe. All fittings shall be swing assemblies with anchor couplings. i. Pipe, Valve and Fitting Wrap: All fittings, valves, fire hydrant shoes and plugs shall be poly-wrapped with 8-mil thick polyethylene plastic wrap, double layered, and ends securely taped prior to backfill. 10. Bedding: All pipe shall be bedded in 3/4" washed rock uniformly graded and compacted. Trench shall be excavated to a depth below established grade equal to 1 4 of pipe diameter (min. 4"). Bell depressions shall be provided for all joints. In event that unstable trench conditions are encountered at pipeline grade 1-1/2" uniformly graded washed rock shall be used for stabilization. Bedding material shall be placed and compacted under and around sides of the pipe. Minimum 30" backfill above pipe before other than hand compaction equipment is to be used. Note maximum trench width detail. 11. Backfill: Backfill of acceptable material shall be placed in lifts not greater than one (1) foot. Backfill shall be compacted to 95% of optimum density in roadway areas or per road authority’s requirements, and 90% in all other locations. Compaction testing of bedding and backfill shall be at least five tests per 1,000 feet and at varying depths and locations in accordance with the requirements of the applicable authority. 12. Joint Restraint: All fittings, tees, plugs and fire hydrants shall be provided with anchor couplings and/or joint restraint in accordance with District Specifications or as required per engineer’s design. Thrust blocks shall be used only as required per field conditions and as approved or directed by the District field inspector. 13. Concrete: All concrete construction, including thrust blocks, shall be completed utilizing Type 5 or equal cement only. 14. Asphalt Replacement: For asphalt pavement that is cut and has been in place less than two years (according to City or County Engineer's record), the cut shall be a minimum of 20 feet in width and will be replaced to the specified depth by a paving machine. 15. Pipe Cover: A minimum cover of 4-1/2 feet of cover over top of pipe shall be maintained throughout the waterline and service line installation, particularly in areas of new grading and drainage swales. Extra bury depth may be required to maintain minimum cover at drainage culvert crossings and/or fire hydrant runs. Maximum allowable cover shall be 6 feet, unless specifically approved by the District. 16. Connection to Existing System: All connections to existing waterlines shall be completed at developer's expense by District personnel or the District's authorized contractor with no exception. 17. Inspection: The District shall have the authority to inspect and verify that all construction of facilities is equal to or better than minimum construction requirements as set forth in the District’s Specifications. The District shall also have the authority to assign an inspector to check any and all work, including all materials to be incorporated in the work, excavation, bedding, backfill, testing and all construction methods and practices. 18. Testing and Acceptance: All lines shall be pressure tested, chlorinated and flushed by the Contractor in accordance with District Specifications and under the District's supervision. Upon passing chlorination testing, bacteriological testing will be completed by a State certified water quality control laboratory. Copies of all passing test results, including soils compaction in the area of water main construction, shall be provided to the District. 19. Project As-Built and Record Drawing Requirements: a. As-built drawings are prepared by the contractor. They confirm, in red ink, on-site changes to the original construction documents. The As-built drawings shall be delivered to the project’s design engineer for conversion to Record Drawings. A PDF version shall be delivered to the District. b. Record Drawings are prepared by the project’s design engineer and reflect on-site changes the contractor noted in the As-built drawings. The Record Drawings shall be approved by the District prior to Preliminary Acceptance of the project. Record Drawings are to be delivered to the District in hard copy (11 x 17 format) and electronic format. Hard copy drawing text font size shall be large enough to be legible with font size approved by the District. Electronic format shall be delivered in Adobe (PDF), AutoCAD and ArcView shape files (release version to be confirmed with District at time of submittal). These documents shall accurately reflect any change made in the field which varies from the approved construction plan and including, at a minimum, field dimensions and elevations, horizontal and vertical locations of underground utilities and appurtenances. Include with the Record Drawings a complete copy of the recorded Filing Plat and a written confirmation of total costs of all water system improvements involved. 20. Warranty: The Contractor shall warrant all work associated with the waterline installation including, but not limited to the materials, installation workmanship and surface restoration for a period of two years from date of Preliminary Acceptance. During this warranty period the Contractor shall repair any defects in the work and maintain the work area. At the close of the two-year warranty period and upon satisfactory correction of any deficiencies noted, the District shall accept the constructed lines and appurtenances as the sole property and responsibility of the District. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Drainage Report - N/A by Northern Engineering Services, Inc., shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: Project Datum: NAVD88 City of Fort Collins benchmark 2-01 Located on the North side of Horsetooth Road on the concrete base of the West gate post to the large gravel pit approx. 1 2 mile East of Ziegler Road. Elevation=4861.39 City of Fort Collins benchmark 29-01 Located on the South side of Prospect Road, East of the intersection of the West frontage road of I-25 and Prospect Road, East of the Colorado Welcome Center, on a concrete headwall to an irrigation pipe. Elevation=4904.41 Basis of Bearings Assuming the North line of the Northeast Quarter of Section 21, T.7N., R.69W., as bearing North 88°38'29" West being a Grid Bearing of the Colorado State Plane Coordinate System, North Zone, North American Datum 1983/92, a distance of 2642.40 feet with all other bearings contained herein relative thereto. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: N.A. CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. See separate SWMP - N/A for additional information. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Drainage Report - N/A by Northern Engineering Services, Inc., shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. C0.01 GENERAL & CONSTRUCTION NOTES B. Ruch M. Kuehnel N/A 2 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT General Manager Date EAST LARIMER COUNTY WATER DISTRICT UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} contained herein relative thereto. Northern Engineering Services, Inc NE Project No. 232-043 Date: March 03, 2013 ORIGINAL FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: PROJECT BENCHMARKS: SHEET INDEX C0.00 COVER SHEET C0.01 GENERAL & CONSTRUCTION NOTES C0.02 ELCO & BOXELDER GENERAL NOTES & TYPICAL ROADWAY SECTIONS C1.00-C1.02 EXISTING CONDITIONS & DEMOLITION PLAN C2.00 OVERALL UTILITY PLAN C2.01-C2.02 12" WATER LINE PLAN & PROFILE C2.03-C2.08 FUTURE 12" WATER LINE PLAN & PROFILE C2.10 SANITARY LINES A & A2 PLAN & PROFILE C2.11 SANITARY LINE B PLAN & PROFILE C2.12-C2.13 FUTURE SANITARY LINE A PLAN & PROFILE C2.14-C2.15 FUTURE SANITARY LINE A2 PLAN & PROFILE C2.16-C2.18 FUTURE SANITARY LINE B PLAN & PROFILE C2.20 CULVERTS 1, 2, & 3 PLAN & PROFILE C3.00 OVERALL GRADING PLAN C4.00-C4.02 SW FRONTAGE ROAD-INTERIM PLAN & PROFILE C5.00-C5.01 UTILITY DETAILS C5.02 DRAINAGE DETAILS C5.03 SITE DETAILS C6.00 EROSION CONTROL PLAN C6.01 EROSION CONTROL DETAILS PUBLIC IMPROVEMENT CONSTRUCTION PLANS FOR Being Part Of Section 21 And Section 22, Township 7 North, Range 68 West Of The 6th P.M., City Of Fort Collins, County Of Larimer, State Of Colorado SW PROSPECT & I-25 Colorado State University Research Foundation (CSURF) Michael 'Bo' Brown P.O. Box 483 Fort Collins, Colorado 80522 (970) 472-0491 The Birdsall Group Kristin Turner 444 Mountain Ave. Berthoud, Colorado 80513 (970) 532-5891 Colorado State University Research Foundation (CSURF) Michael 'Bo' Brown P.O. Box 483 Fort Collins, Colorado 80522 (970) 472-0491 Earth Engineering Company, Inc. David A. Richer, PE 4396 Greenfield Drive Windsor, Colorado 80550 (970) 545-3908 GEOTECHNICAL ENGINEER Matt Delich, PE Delich Associates 2272 Glen Haven Drive Loveland, Colorado 80538 (970) 669-2061 TRAFFIC & TRANSPORTATION ENGINEERING TRAFFIC ENGINEER Blue Mountain Environmental Consulting, LLC Matt Tobler, Natural Resource Specialist 937 Mallard Drive Fort Collins, Colorado 80521 (970) 224-0851 ENVIRONMENTAL ENGINEER E N G I N E E R I N G N O R T H E RN E N G I N E E R I N G N O R T H E RN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C0.00 COVER SHEET B. Ruch M. Kuehnel N/A 1 No. Revisions: By: Date: P. MANAGER: C. Snowdon DESIGNED BY: DRAWN BY: SCALE: DATE: 10/10/18 PROJECT: 232-043 Sheet SW PROSPECT & I-25 These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 10/10/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 35 MANAGER APPROVED: DATE: APPROVED: DATE: SYSTEMS ENGINEER UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT General Manager Date EAST LARIMER COUNTY WATER DISTRICT UTILITY PLAN REVIEW {Review does not constitute "approval" of plans. Plan Engineer is responsible for accuracy and completeness of design.} Earth Engineering, Inc. "Preliminary Subsurface Exploration Report CSURF 25-Acre Parcel Southwest of East Prospect Road and 1-25" Fort Collins, Colorado EEC Project no. 1072151 Date: November 9, 2007 Clay Frickey / Tenae Beane Routed 10/30/2018 *Scroll down for more information on the projects that have been routed this week Routed Minor Amendments and County Referrals Project Name Project Number Zoning Facilitator/Planner Routed Date Comments Due Date Lakeview on the Rise MA180067 Arlo Schumann 10/15/2018 10/29/2018 Dogtopia MA180068 Jamie Kimberlin 10/15/2018 10/29/2018