Loading...
HomeMy WebLinkAboutFTC OLD TOWN WTE (VERIZON) - BDR180018 - SUBMITTAL DOCUMENTS - ROUND 4 - PLANSFTC OLD TOWN LIBRARY 201 PETERSON ST. FORT COLLINS, CO 80524 MACRO CELL CONSTRUCTION DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS FROM SOUTH VAUGHN WAY MERGE ONTO ON I-225 N FROM SOUTH URSULA ST, S.VAUGHN WAY AND E. ILIFF AVE. FROM I-225 N TAKE E-470 N TO I-25 N. TAKE I-25 N TO CO-14 W/E MULBERRY ST IN LARIMER COUNTY. TAKE EXIT 269B FROM I-25 N. FOLLOW E. MULBERRY ST TO PETERSON ST IN FORT COLLINS. FORT COLLINS, COLORADO CLIENT PROJECT DATA CODE ANALYSIS IBC 2015 (W/LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET PROJECT DESCRIPTION 1. INSTALL (2) NEW EQUIPMENT CABINETS ON STEEL PLINTH ON ROOF OF BUILDING. 2. INSTALL (12) NEW ANTENNAS ON CUSTOM TRI SECTOR MOUNT. 3. (6) PROPOSED AND (6) FUTURE REMOTE RADIO HEADS ON CUSTOM TRI SECTOR MOUNT. 4. INSTALL (3) NEW OVP'S ON CUSTOM TRI SECTOR MOUNT. 5. INSTALL NEW LOAD CENTER, STEP-DOWN TRANSFORMER AND ASSOCIATED ELECTRICAL EQUIPMENT ON ROOFTOP OF EXISTING BUILDING. 6. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT. 7. INSTALL (3) HYBRID CABLES AND ASSOCIATED COAX CABLES. 8. INSTALL NEW RF TRANSPARENT SHROUD. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FORT COLLINS ZONING: DOWNTOWN DISTRICT APN: 9712321901 PARCEL SIZE: 2.92 AC ELEVATION: 4,977' (NAVD 88) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 41'-0"± (TOP OF STRUCTURE) ANTENNA RAD CENTER: 48'-0" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: BRANDON KISER 9656 S. PROSPERITY RD GENERAL NOTES GN-1 2 REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 09/22/17. 2. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 4. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 6. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 7. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs 1 PH-1 PHOTOSIMULATION (BEFORE, LOOKING SOUTHEAST) SCALE: N.T.S. 2 PH-1 PHOTOSIMULATION (AFTER, LOOKING SOUTHEAST) SCALE: N.T.S. PHOTOSIMULATIONS PH-1 3 E ET VP VP VP VP VP VP GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS T T SS SS SS SS UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE F F F F F F F F F F F G M F F F F F F F F F EM E ET E ET VP VP VP VP VP VP VP GAS GAS GAS GAS GAS GAS GAS GAS GAS GAS T T SS SS SS SS UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE F F F F F F F F F F F GM F F F F F F F F F F EM E E T VP VP EE F SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W EXISTING 66'-0" ET VP VP VP VP VP GAS GAS GAS GAS GAS GAS GAS UE UE UE UE UE UE GM EM E E E E E E E ET ET VP VP VP VP VP VP GAS GAS GAS GAS GAS GAS GAS UE UE UE UE UE UE GM F F F F F F EM E E E E E E E ET VP VP E E E E E E E E E E E E E E E E F F F F F F F 18'-0" 18'-0" 6'-0" 2'-0" 7'-0" 23'-0" 2'-6" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY LIBRARY 27'-0" 30'-0" 41'-0" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 1 C-1 EXISTING EAST ELEVATION SCALE: 3/16"=1'-0" 3/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 8 16 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) TOP OF ROOF 27'-0" AGL EXISTING ELEVATION C-1 6 EXISTING SKYLIGHT (TYP) EXISTING HVAC UNIT TOP OF PARAPET LIBRARY 27'-0" 30'-0" 41'-0" 48'-0" 52'-0" 55'-0" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 1 C-2 PROPOSED EAST ELEVATION SCALE: 3/16"=1'-0" 3/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 8 16 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) TOP OF ROOF 27'-0" AGL PROPOSED ELEVATION C-2 7 3'-0" 6'-0" 2" 2'-10" 3'-0" 2'-10" FRONT VIEW LEFT SIDE VIEW TOP VIEW FRONT VIEW LEFT SIDE VIEW TOP VIEW 6'-0" 2" 2'-6" 2'-10" 2'-6" 2'-10" 4'-8" 10'-0" 10'-0" 4'-8" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 1 C-3 RBA72 CABINET DETAIL SCALE: 3/4"=1'-0" 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1'-0" MIN. 4" 2'-6" 1'-6" 6" MIN. (TYP) 4" MIN. TO SECONDARY ELECTRIC 12" MIN. TO PRIMARY ELECTRIC NOTES: 1. CONTRACTOR TO ORDER HANDHOLE BOX WITH THE CORRECT NUMBER AND SIZE OF KNOCKOUTS NEEDED. 2. VERIFY DIMENSIONS OF UNIT. 24" 26" 30" BOX COVER 37 5/8" 35 3/8" 16.5" 29.5" 12.6" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs NOTE: 1. ALL SUPPORT/ANCHOR HARDWARE TO BE HOT DIPPED GALVANIZED OR STAINLESS STEEL. 2. VERIFY PLACEMENT DOES NOT BLOCK EXISTING WINDOWS ON BUILDING. CONSTRUCTION DETAILS (CONTINUED) C-4 1'-8" 2'-4" 7" MIN 7'-0" MIN 8'-0" MAX 3'-6" MIN. 6'-0" 14'-0"± REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs PROPOSED LADDER CAGE PROPOSED LADDER TOP OF PENTHOUSE (CONTRACTOR TO VERIFY EXACT HEIGHT PRIOR TO INSTALLATION) TOP OF PENTHOUSE TOP OF PENTHOUSE (CONTRACTOR TO VERIFY EXACT HEIGHT PRIOR TO INSTALLATION) 1 C-5 CAGED LADDER ELEVATION DETAILS SCALE: 3/4" = 1'-0" 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ET VP VP VP W W W VP GAS E UE UE GM EM ET VP VP VP VP W W W VP GAS E UE UE GM EM ET VP VP 2'-6" REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs EME DETAILS 11 4'-0" (TYP) 2'-0" (TYP) REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs ANTENNA PLAN A-1 12 A-1 0° 48'-0" TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - HYBRID 6x12 94 FT. A-2 A-3 B-1 B-2 B-3 G-1 G-2 G-3 ANTENNA & CABLE SCHEDULE SECTOR AZIMUTH MOUNTING HEIGHT ANTENNA MODEL TECHNOLOGY ANTENNA SPECIFICATIONS MECHANICAL DOWNTILT ELECTRICAL DOWNTILT CABLE SIZE CABLE 5'-0" ET VP VP VP VP VP GM EM ET ET VP VP VP VP VP VP GM EM ET VP VP EE THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. N 1 U-1 UTILITY PLAN SCALE: 1"=10'-0" UTILITY PLAN SCHEDULE QUANTITY 1 POWER NOTES: 1. SERVICE SHALL BE 480/277V, 3ɸ, 4W, 100A 2. CONTRACTOR TO COORDINATE INSPECTION AND PLACEMENT OF METER WITH THE LOCAL UTILITY COMPANY: FTC L&P CONTACT: PHONE: XXXXXXXX W.O. NUMBER: XXXXXXX ITEM LENGTH PROVIDED BY INSTALLED BY TRANSFORMER - FTC L&P N/A DESCRIPTION EXISTING 277/480V, 3ɸ, 4W, 300kVA 1 CONDUITS - LNE TO METER 2" PVC 20'± CONTRACTOR 3 CONDUCTORS - LINE TO METER 20'± CONTRACTOR (4)-#3 AWG AWG CU CONDUCTORS CONTRACTOR CONTRACTOR 1 DISCONNECT - CONTRACTOR LEVER-TYPE 480/277V 100A FUSED ET VP GAS GAS GAS UE UE UE UE UE UE UE UE UE UE GM EM E E E E E E E E E E E E E E E E E ET ET VP GAS GAS GAS UE UE UE UE UE UE UE UE UE UE GM EM E E E E E E E E E E E E E E E E E ET E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs ASCO ASCO REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs 1 E-2 ONE-LINE DIAGRAM SCALE: N.T.S ONE-LINE DIAGRAM & ELEVATION E-2 15 EXISTING 255KVA 3Ø, 277/480V TRANSFORMER FAULT: 16,040A PROPOSED 22K AIC RATED METER WITH COLD SEQUENCE SERVICE DISCONNECT FAULT: 14,261A (L-L) PROPOSED 100A LEVER-TYPE MAIN DISCONNECT PROPOSED 25KVA, 3ɸ 277/480V - 120/240V STEP-DOWN TRANSFORMER FAULT: 1,793A PROPOSED 200A, 2 POLE, 120/240V, 1-PHASE INTEGRATED LOAD CENTER (ILC) WITH MANUAL TRANSFER SWITCH (MTS) FAULT: 2,606A (L-N) 20' PROPOSED (4)-#3 AWG CU CONDUCTORS IN 2" PVC CONDUIT PANEL CIRCUIT AND LOAD SCHEDULE SERVICE: DESIGNATION: LOCATION: TOTAL KVA CONTINUOUS x 1.25 TOTAL KVA NON-CONTINUOUS TOTAL KVA TOTAL AMPS 33.68 0 33.68 140.31 REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs 1 E-3 PANEL SCHEDULE SCALE: N.T.S. PANEL SCHEDULE E-3 16 ET REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs N 1 G-2 GROUNDING PLAN SCALE: 1/2"=1'-0" 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) GROUNDING PLAN G-1 17 PROPOSED INTEGRATED LOAD CENTER MOUNTED ON UNISTRUT TO EXTERIOR OF PENTHOUSE PROPOSED CHASE ON SIDE OF BUILDING FOR FIBER AND POWER ROUTING TO EQUIPMENT (PAINT TO MATCH EXISTING BUILDING) PROPOSED (2)-#2 GREEN THIN GROUND WIRE FROM ANTENNA TYPE NC TYPE GT TYPE GL LUG TYPE HA TYPE GR TYPE VS TYPE HS TYPE SS TYPE XA TYPE PT (2) (3) (5) (4) (1) MGB 2 EM SGC424-VZW OR EQUAL GALVANIZED STEEL GROUND BAR, BY ELECTRIC MOTION COMPANY (SEE SCHEDULE BELOW). INSULATORS, BY HARGER CAT. #5263-A5. 5/8 " LOCKWASHERS, STAINLESS STEEL. WALL MOUNTING BRACKET, HARGER CAT. #WBKT-2. 5/8-11x3" H.H.C.S. BOLTS, STAINLESS STEEL. (2) (3) (4) (5) (1) LEGEND OR EQUAL REMARKS EM SGC412-VZW CAT. NO. ELECTRIC MOTION COMPANY MANUFACTURER CGB 3 TYPE QTY. GROUND BAR SCHEDULE ELECTRIC MOTION COMPANY "GALV STEEL" STEEL STAMPED ON EITHER END CADWELD AT TWO LOCATIONS 3'-6" FINISHED GRADE 1'-0" 36" THREADED PVC PIPE CAP 2" SLOTTED HOLE (TYP) 5/8"X10'-0" GALVANIZED GROUND ROD.TOTAL DEPTH IN SOIL TO BE 8'-0" MIN. EXOTHERMIC CAD WELD (2) #2 AWG BARE SOLID GROUND WIRE 6" Ø PVC PIPE REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 E ET VP VP GAS GAS UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE F F F F F F F F F F F G M F F F F F F F F F EM E ET E ET VP VP GAS GAS UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE F F F F F F F F F F F GM F F F F F F F F F F EM E ET EE F W W W W W W W W W W W EXISTING 66'-0" VACATED RIGHT OF WAY REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 N 1 TM-1 TREE MITIGATION PLAN SCALE: 1"=20'-0" 1 inch = 20ft. ( IN FEET ) GRAPHIC SCALE 20 0 10 20 40 80 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING NATURAL GROUND (TYP) EXISTING BUILDING TREE MITIGATION PLAN TM-1 19 PROPOSED 10'-0" ACCESS EASEMENT EXISTING WALKWAY EAST OLIVE ST. PETERSON ST. NOTE: FIBER LINE TO BE INSTALLED THROUGH BORING TECHNIQUES. BORING TO START NEAR THE RIGHT-OF-WAY ALONG EAST OLIVE STREET AND THEN WORK TOWARD THE BUILDING TO LIMIT THE IMPACT OF BORING EQUIPMENT AND DRILLING NEAR THE CLOSEST TREE TO THE BUILDING. BORE DEPTH TO BE A MINIMUM OF 48" TO AVOID ALL TREE ROOTS. TREE PROTECTION IN THE FROM OF CONCRETE BLANKETS AROUND TREE TRUNKS SHOULD BE INSTALLED PRIOR TO ON-SITE CONSTRUCTION. * ANY DAMAGE TO A TREE AS A DIRECT RESULT OF THIS ACTIVITY WILL RESULT UN FINES EQUAL TO $1,000 PER INCH OF DAMAGED AREA UP TO THE APPRAISED VALUE OF EACH TREE. IF A TREE IS GIRDLED 40% OR HIGHER, THEN THE FULL APPRAISED VALUE OF THE TREE WILL BE COLLECTED BY CITY FORESTRY. 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs CABLE TO ANTENNA CABLE GROUNDING CLAMP KIT #6 AWG GREEN INSULATED COPPER GROUNDING CONDUCTOR CABLE TO EQUIPMENT 3M SCOTCH SUPER 33+ VINYL ELECTRICAL TAPE (OR APPROVED EQUAL) PROPOSED COAX VAPOR WRAP SEALANT COAX TO JUMPER CONNECTION PROPOSED JUMPER 2 G-2 TYPICAL CABLE GROUNDING SCALE: N.T.S. 4 G-2 WEATHERPROOFING DETAIL SCALE: N.T.S. 5 G-2 TYPICAL CADWELD TYPE CONNECTIONS SCALE: N.T.S. 6 G-2 GROUND BAR DETAIL SCALE: N.T.S. EACH ANTENNA SECTOR (TYP) COAX TYP. #6 THWN GREEN INSULATED (TYP) SECTOR AGB #2 AWG SOLID BTCW #2 AWG SOLID BTCW #2 AWG SOLID BTCW HYBRIFLEX AND COAX GROUND KIT #6 THWN GREEN INSULATED MGB AT EQUIPMENT PLATFORM #2 AWG SOLID BTCW EXISTING GROUND ROD AT GRADE ANTENNA RRH MOUNTING ANTENNA MOUNTING MOUNTING ANTENNA MOUNTING OVP RRH RRH 3 G-2 GROUND ROD DETAIL SCALE: N.T.S. 1 G-2 GROUNDING RISER DIAGRAM SCALE: N.T.S. GROUNDING DETAILS G-2 18 RRH ANTENNA GROUND BAR TO MASTER GROUND BAR PROPOSED CADWELD (TYP) PROPOSED EQUIPMENT CABINET PROPOSED MASTER GROUND BAR PROPOSED BATTERY CABINET (SEE DETAIL 3/G-2) PROPOSED (2)-#2 BARE TINNED SOLID COPPER GROUND WIRE ROUTED DOWN TO PROPOSED GROUND ROD AT GRADE PROPOSED (2)-#2 BARE TINNED SOLID COPPER GROUND WIRE ROUTED DOWN TO PROPOSED GROUND ROD AT GRADE PROPOSED 5/8"Øx10'-0" GROUND ROD BURIED 36" BELOW GRADE (SEE DETAIL 3/G-2) PROPOSED GROUND WIRE FROM ILC TO MASTER GROUND BAR PROPOSED GROUND WIRE FROM EQUIPMENT CABINET TO MASTER GROUND BAR (TYP OF 2) PROPOSED (2)-#2 GREEN THHN GROUND WIRE TO MASTER GROUND BAR AT EQUIPMENT PLATFORM PROPOSED GROUND BAR PROPOSED #6 AWG GROUND WIRE TO OVP (TYP) PROPOSED #6 AWG GROUND WIRE TO RRH'S (TYP) PROPOSED #6 AWG GROUND WIRE TO ANTENNA (TYP) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) (2) PROPOSED AND (2) FUTURE VERIZON RRH'S MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) PROPOSED 16'-8"x 16'-8" VERIZON CONCEALMENT WALL PROPOSED VERIZON OVP MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 1 PER SECTOR, 3 TOTAL) PROPOSED 2'-6" WIDE ACCESS DOOR FOR CONCEALMENT WALL (FINAL DESIGN TBD) PROPOSED GROUND WIRE FROM TRANSFORMER TO MASTER GROUND BAR PROPOSED 25KVA, 1Ø 277/480V - 120/240V STEP-DOWN TRANSFORMER 100' PROPOSED (4)-#3 AWG CU CONDUCTORS (1)-#8 AWG CU GROUND IN 2" PVC CONDUIT NOTES: 1. ELECTRICAL SERVICE SHALL BE 100A. 2. SERVICE SHALL BE INSTALLED WITH A LEVER TYPE DISCONNECT. 3. FOR COMPLETE INTERNAL WIRING AND ARRANGEMENT, REFER TO VENDOR PRINTS PROVIDED BY EQUIPMENT CABINET MANUFACTURER. 4. METER BY FT. COLLINS L&P. SEE INTERNAL WIRING DIAGRAM PROVIDED BY MANUFACTURER FOR DETAILS. 5. VERIZON TO PULL 70.16A FROM ELECTRICAL SERVICE. 2 E-2 ONE-LINE ELEVATION SCALE: N.T.S EXISTING 255KVA 3Ø, 277/480V TRANSFORMER FAULT: 16,040A PROPOSED 25KVA, 3ɸ 277/480V - 120/240V STEP-DOWN TRANSFORMER FAULT: 1,793A (L-L) PROPOSED 22K AIC RATED METER WITH COLD SEQUENCE SERVICE DISCONNECT FAULT: 14,261A (L-L) PROPOSED (4)-#3 AWG CU CONDUCTORS (1)-#8 AWG CU GROUND IN 2" PVC CONDUIT PROPOSED VERIZON EQUIPMENT CABINETS PROPOSED 200A, 2 POLE, 120/240V, 1-PHASE INTEGRATED LOAD CENTER (ILC) WITH MANUAL TRANSFER SWITCH (MTS) FAULT: 2,606A (L-N) 100' PROPOSED (4)-#3 AWG CU CONDUCTORS (1)-#8 AWG CU GROUND IN 2" PVC CONDUIT PROPOSED SERVICE ENTRY GROUND LEAD 10' PROPOSED (3)-3/0 AWG CU CONDUCTORS (1)-#6 AWG CU GROUND IN 2" PVC CONDUIT PROPOSED LEVER TYPE CUSTOMER DISCONNECT 10' PROPOSED (3)-3/0 AWG CU CONDUCTORS (1)-#6 AWG CU GROUND IN 2" PVC CONDUIT 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 N 1 E-1 ELECTRICAL PLAN SCALE: 3/8"=1'-0" 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 6 8 10 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELECTRICAL PLAN E-1 14 10' PROPOSED (3)-3/0 AWG CU CONDUCTORS (1)-#6 AWG CU GND IN 2" PVC CONDUIT ROUTED ON SLEEPERS ALONG ROOFTOP TO EQUIPMENT CABINETS 20' PROPOSED (4)- #3 AWG CU CONDUCTORS (1)-#8 AWG CU GROUND IN 2" PVC CONDUIT EXISTING 300 KVA, 277/480V 3ɸ TRANSFORMER FAULT: 16,040A (L-L) PROPOSED CHASE ON SIDE OF BUILDING FOR FIBER AND POWER ROUTING TO EQUIPMENT (PAINT TO MATCH EXISTING BUILDING) 50' PROPOSED (4)- #3 AWG CU CONDUCTORS (1)-#8 AWG CU GROUND IN 2" PVC CONDUIT PROPOSED 200A LOAD CENTER WITH MTS MOUNTED TO UNISTRUT ON EXTERIOR OF PENTHOUSE PROPOSED EQUIPMENT CABINET (SEE DETAIL 1/C-3) PROPOSED BATTERY CABINET (SEE DETAIL 2/C-3) GENERATOR PLUG AT GRADE 42' PROPOSED (4) - #3 AWG CONDUCTORS (1) - #8 AWG GND IN 2" PVC FROM GENERATOR ROUTED ON SLEEPERS ALONG ROOFTOP TO EQUIPMENT CABINETS PROPOSED 25KVA, 3ɸ 277/480V - 120/240V STEP-DOWN TRANSFORMER FAULT: 1,793A (L-L) PROPOSED METER WITH SERVICE DISCONNECT MOUNTED ON WALL PROPOSED MANUAL TRANSFER SWITCH WITHIN LOAD CENTER FAULT: 2,285A (L-L) PROPOSED LEVER TYPE CUSTOMER DISCONNECT CONTRACTOR 1 METER SOCKET TYP - CONTRACTOR CONTRACTOR 1 METER TYP - FTC L&P FTC L&P REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs UTILITY PLAN U-1 13 PROPOSED 2'-0"X3'-0" FIBER VAULT (TYP OF 2) (SEE DETAIL 5/C-4) (VAULT TO BE PLACED AT EDGE OF PROPERTY LINE. FIBER TO BE BROUGHT TO VAULT FROM R.O.W. BY OTHERS) 1 inch = 10ft. ( IN FEET ) GRAPHIC SCALE 10 0 5 10 20 40 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 20' PROPOSED (4) - #3 AWG CU CONDUCTORS IN 2" PVC CONDUIT FROM EXISTING TRANSFORMER TO NEW UTILITY METER AND DISCONNECT MOUNTED TO EXTERIOR WALL PROPOSED METER & DISCONNECT MOUNTED ON EXTERIOR WALL (SEE E-3 FOR MORE DETAIL) PROPOSED 2'-0"x3'-0" FIBER VAULT (SEE DETAIL 5/C-4) 42' PROPOSED (3)-#3 AWG CU CONDUCTORS (1)-#8 AWG CU GND IN 2" PVC CONDUIT ROUTED ON SLEEPERS ALONG ROOFTOP TO EQUIPMENT CABINETS EXISTING 300 KVA, 277/480V 3ɸ TRANSFORMER FAULT: 16,040A (L-L) 50' PROPOSED (4)-#3 AWG CU CONDUCTORS (1)-#8 AWG CU GROUND IN 2" PVC CONDUIT PROPOSED 200A LOAD CENTER WITH MTS MOUNTED TO UNISTRUT ON EXTERIOR OF PENTHOUSE PROPOSED 25KVA, 3ɸ 480 - 120/240V STEP-DOWN TRANSFORMER FAULT: 11,770A (L-L) 10' PROPOSED (3)-3/0 AWG CU CONDUCTORS (1)-#6 AWG CU GND IN 2" PVC CONDUIT ROUTED ON SLEEPERS ALONG ROOFTOP TO EQUIPMENT CABINETS LENGTH COMMSCOPE JAHH-65C-R3B (SHARED HYBRID) - 0° TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B 0° TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B (SHARED HYBRID) - 120° TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - HYBRID 6x12 98 FT. COMMSCOPE JAHH-65C-R3B (SHARED HYBRID) - TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B (SHARED HYBRID) - 240° TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B (SHARED HYBRID) - TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B (SHARED HYBRID) - HYBRID 6x12 94 FT. 48'-0" 48'-0" A-4 0° TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - (SHARED HYBRID) - 48'-0" COMMSCOPE JAHH-65C-R3B B-4 TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B (SHARED HYBRID) - 120° 120° 120° 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 240° 240° G-4 240° TBD 95.7"(L) x 13.8"(W) x 8.2"(D) 80.2 LBS - - COMMSCOPE JAHH-65C-R3B (SHARED HYBRID) - SECTOR A VERIZON ANTENNA AZ= 0° SECTOR B VERIZON ANTENNA AZ= 120° SECTOR C VERIZON ANTENNA AZ= 240° 1 A-1 ANTENNA PLAN SCALE: 1/2"=1'-0" 1/2 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 2 0 1 2 4 8 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) (2) PROPOSED AND (2) FUTURE VERIZON RRH'S MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) PROPOSED 16'-8"x 16'-8" VERIZON CONCEALMENT WALL PROPOSED 2'-0"x 2'-0" BRICK PAVER ON ROOFTOP FOR ACCESS TO ALL EQUIPMENT LOCATIONS PROPOSED HYBRID CABLE ROUTED IN EMT CONDUIT ON 36" SLEEPERS FROM EQUIPMENT CABINETS TO OVP'S ON TRI-SECTOR MOUNT (SEE DETAIL 3/C-4) PROPOSED VERIZON OVP MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 1 PER SECTOR, 3 TOTAL) PROPOSED CUSTOM TRI-SECTOR MOUNT (SEE STRUCTURAL SHEETS FOR MORE DETAIL) PROPOSED 2'-6" WIDE ACCESS DOOR FOR CONCEALMENT WALL (FINAL DESIGN TBD) 2 A-1 ANTENNA MOUNTING ELEVATION SCALE: 3/8"=1'-0" N PROPOSED CUSTOM TRI-SECTOR MOUNT (SEE STRUCTURAL SHEETS FOR MORE DETAIL) PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) 3/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 6 8 10 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) (2) PROPOSED AND (2) FUTURE VERIZON RRH'S MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) PROPOSED VERIZON OVP MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 1 PER SECTOR, 3 TOTAL) C-6 NOTES: 1. FCC GUIDELINES AND NOC INFO SIGNS TO BE POSTED AT ALL PERMANENT ACCESS POINTS. 2. REFER TO FINAL EME DESIGN BY VERIZON PRIOR TO TURNING SITE ON. 1 C-6 EME PLAN SCALE: 1/8"=1'-0" 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) CAUTION AND GUIDELINES SIGNS SHOULD BE INSTALLED AT THE BACK OF THE ALPHA SECTOR EXISTING PENTHOUSE ROOF QUANTITY: 6 QUANTITY: 1 QUANTITY: 3 QUANTITY: 1 QUANTITY: 1 PROPOSED REFLECTIVE FIBERGLASS POST (TYP) (PAINTED TO MATCH BUILDING) PROPOSED RUBBER POST BASE (TYP) PROPOSED FIBERGLASS CHAIN (TYP) (PAINTED TO MATCH BUILDING) SECURE PROPOSED SIGNAGE TO FIBERGLASS CHAIN WITH STAINLESS STEEL HOSE CLAMPS (TYP) 2 C-6 EME BARRIER DETAIL SCALE: N.T.S. EXISTING LOWER ROOF LEFT ARROW FCC NOTICE & GUIDELINES SIGN SHOULD BE INSTALLED AT THE PROPOSED BARRIER PROPOSED 6'-0" WIDE EME BARRIER (PAINTED TO MATCH BUILDING) (SEE DETAIL 2/C-6) PROPOSED REFLECTIVE MARKER (TYP) CAUTION AND GUIDELINES SIGNS SHOULD BE INSTALLED AT THE FRONT OF THE BETA & GAMMA SECTOR FCC NOTICE AND GUIDELINES SIGNS SHOULD BE INSTALLED AT THE MARKER EXISTING ROOF ACCESS HATCH NOC & GUIDELINES SIGNS SHOULD BE INSTALLED AT THE ROOF ACCESS HATCH CONSTRUCTION DETAILS (CONTINUED) C-5 10 TOP OF ROOF TOP OF ROOF TOP OF PENTHOUSE PROPOSED LADDER CAGE PROPOSED LADDER 9 1 C-4 WALL MOUNTED CONDUIT DETAIL N.T.S. ANCHOR TO WALL WITH (2) HILTI 3/8"X3-1/2" (EMBEDMENT) HIT THREADED ROD WITH HIT HY-150 INJECTION ADHESIVE PROPOSED CHASE CONCEALMENT (PAINT TO MATCH EXISTING BUILDING) EMT CONDUIT FOR POWER EMT CONDUIT FOR FIBER EMT CONDUIT FOR GROUND CONDUIT CLAMP P1000 UNISTRUT (6'-0" O.C.) NOTES: 1. FOR EMT CONDUIT, MAX PROPOSED SPACING BETWEEN SLEEPERS IS 10' O.C. 2. FOR COAX, MAX PROPOSED SPACING BETWEEN SLEEPERS IS 3' O.C. PROPOSED 4" CONDUIT CLAMP PROPOSED 4" EMT CONDUIT FOR HYBRIFLEX CABLE PROPOSED COOPER DURA BLOK DB10-36 ROOFTOP SUPPORT 3 C-4 HYBRIFLEX CONDUIT DETAIL 2 N.T.S. C-4 FIBER & POWER CONDUIT DETAIL N.T.S. NOTES: 1. FOR EMT CONDUIT, MAX PROPOSED SPACING BETWEEN SLEEPERS IS 10' O.C. 2. FOR COAX, MAX PROPOSED SPACING BETWEEN SLEEPERS IS 3' O.C. PROPOSED COOPER DURA BLOK DB10 ROOFTOP SUPPORT PROPOSED 2" CONDUIT FOR FIBER PROPOSED 2" CONDUIT CLAMP PROPOSED 2" CONDUIT FOR POWER PROPOSED 2" CONDUIT CLAMP NOTE: SEPARATION DIMENSIONS TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS. 4 C-4 UTILITY TRENCH DETAIL N.T.S. 5 C-4 PULLBOX DETAIL N.T.S. FINISHED GRADE OR PAVING. MATCH SLOPE AND THICKNESS OF EXISTING CONDITIONS 3"Ø SCH 40 PVC POWER CONDUIT (AS REQUIRED) BACKFILL (SAND OR NATIVE SOIL) PER ASTM STANDARDS UNDISTURBED SOIL UTILITY WARNING TAPE 2"Ø SCH 40 PVC FIBER CONDUIT (AS REQUIRED) 0.5 CDF SKID RESISTANT SURFACE 5/8"x4" PULL SLOT MAKE: HUBBELL 24"X36" FRP STRAIGHT WALL MODEL: B16243630A LIFTING INSERTS (4) FRONT VIEW SIDE VIEW NOTE: FOR HYBRID CABLE RUNS OVER 262', THE CONTRACTOR IS TO ADD BRIDGE KIT MODEL# RM-3315-WB-KIT & 3315-WB-KIT. MOUNTING BRACKET 6 C-4 OVP DETAIL N.T.S. EMT CONDUIT FOR GENERATOR PLUG BOTTOM VIEW 1 0 1 2 3 4 5 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 C-3 RBA72 BATTERY CABINET DETAIL SCALE: 3/4"=1'-0" 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 3 C-3 CABINET PLINTH DETAIL SCALE: 3/4"=1'-0" 3/4 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 3 4 5 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) CONSTRUCTION DETAILS C-3 8 PROPOSED 16'-8"x 16'-8" VERIZON CONCEALMENT WALL PROPOSED CAGED ACCESS LADDER FROM LOWER ROOFTOP TO PENTHOUSE (SEE SHEET C-5 FOR MORE DETAIL) EXISTING SKYLIGHT (TYP) TOP OF PARAPET 30'-0" AGL TOP OF STRUCTURE 41'-0" AGL PROPOSED VERIZON RAD CENTER 48'-0" AGL TOP OF PROPOSED VERIZON ANTENNA 52'-0" AGL TOP OF PROPOSED CONCEALMENT SHROUD 55'-0" AGL PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 16 TOTAL) (SEE DETAIL 2/A-1) (2) PROPOSED AND (2) FUTURE VERIZON RRH'S MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 16 TOTAL) (SEE DETAIL 2/A-1) PROPOSED VERIZON OVP MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 1 PER SECTOR, 3 TOTAL) (SEE DETAIL 2/A-1) GRADE 0'-0" AGL PROPOSED VERIZON CUSTOM TRI-SECTOR MOUNT (SEE STRUCTURAL SHEETS FOR MORE DETAIL) 30'-0" AGL TOP OF STRUCTURE 41'-0" AGL GRADE 0'-0" AGL SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 N 1 Z-2 ENLARGED SITE PLAN SCALE: 3/16"=1'-0" 1 C-2 3/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 1 0 1 2 4 8 16 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING PENTHOUSE EXISTING ROOF ENLARGED SITE PLAN Z-2 5 PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) (SEE DETAIL 2/A-1) PROPOSED 18'-0"x 18'-0" VERIZON LEASE AREA (2) PROPOSED AND (2) FUTURE VERIZON RRH'S MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) (SEE DETAIL 2/A-1) PROPOSED 16'-8"x 16'-8" VERIZON CONCEALMENT WALL PROPOSED 2'-0"x 2'-0" BRICK PAVER ON ROOFTOP FOR ACCESS TO ALL EQUIPMENT LOCATIONS PROPOSED HYBRID CABLE ROUTED IN EMT CONDUIT ON 36" SLEEPERS FROM EQUIPMENT CABINETS TO OVP'S ON TRI-SECTOR MOUNT (SEE DETAIL 3/C-4) PROPOSED CAGED ACCESS LADDER FROM LOWER ROOFTOP TO PENTHOUSE (SEE SHEET C-5 FOR MORE DETAIL) PROPOSED FIBER AND POWER FROM GROUND ROUTED ON SLEEPERS WITH CONDUIT TO EQUIPMENT CABINETS (SEE DETAIL 2/C-4) EXISTING BRICK PAVER (TYP) PROPOSED NEW POWER RUN FROM EXISTING TRANSFORMER TO NEW UTILITY METER AND DISCONNECT MOUNTED TO EXTERIOR WALL EXISTING ROOF ACCESS HATCH EXISTING TRANSFORMER (AT GRADE) PROPOSED CHASE ON SIDE OF BUILDING FOR FIBER AND POWER ROUTING TO EQUIPMENT (PANT TO MATCH EXISTING BUILDING) PROPOSED 2'-0"x3'-0" FIBER VAULT (SEE DETAIL 5/C-4) 2 PROPOSED VERIZON EQUIPMENT CABINETS ON STEEL SKID (SEE SHEET C-3 FOR MORE DETAIL) PROPOSED 7'-0"x23'-0" VERIZON LEASE AREA SECTOR A VERIZON ANTENNA AZ= 0° SECTOR B VERIZON ANTENNA AZ= 120° SECTOR C VERIZON ANTENNA AZ= 240° PROPOSED EME BARRIER (SEE SHEET C-6 FOR MORE DETAIL) PROPOSED METER & DISCONNECT MOUNTED ON EXTERIOR WALL (SEE E-3 FOR MORE DETAIL) PROPOSED VERIZON CUSTOM TRI-SECTOR MOUNT (SEE STRUCTURAL SHEETS FOR MORE DETAIL) VACATED RIGHT OF WAY REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 N 1 Z-1 SITE PLAN SCALE: 1"=20'-0" LONG LAT SITE COORDINATES 105° 04' 21.53" WEST (NAD 83) 40° 35' 06.01" NORTH (NAD 83) NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION. 1 inch = 20ft. ( IN FEET ) GRAPHIC SCALE 20 0 10 20 40 80 (SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) EXISTING NATURAL GROUND (TYP) EXISTING BUILDING PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL (TYP OF 4 PER SECTOR, 12 TOTAL) SITE PLAN Z-1 4 PROPOSED 2'-0"x3'-0" FIBER VAULT (TYP OF 2) (SEE DETAIL 5/C-4) (VAULT TO BE PLACED AT EDGE OF PROPERTY LINE. FIBER TO BE BROUGHT TO VAULT FROM R.O.W. BY OTHERS) PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT (SEE DETAIL 4/C-4) PROPOSED 10'-0" WIDE UTILITY EASEMENT PROPOSED 18'-0"x 18'-0" VERIZON LEASE AREA PROPOSED 10'-0" ACCESS EASEMENT EXISTING WALKWAY PROPOSED CAGED ACCESS LADDER FROM LOWER ROOFTOP TO PENTHOUSE (SEE SHEET C-5 FOR MORE DETAIL) 2 PROPOSED VERIZON EQUIPMENT CABINETS ON STEEL SKID (SEE SHEET C-2 FOR MORE DETAIL) PROPOSED FIBER AND POWER ROUTED UP SIDE OF BUILDING IN CHASE (PANT TO MATCH EXISTING BUILDING) (SEE DETAIL 1/C-4) PROPOSED 7'-0"x 23'-0" VERIZON LEASE AREA EAST OLIVE ST. PETERSON ST. NOTE: EXISTING ADJACENT UTILITIES HAVE NOT BEEN FIELD VERIFIED AND HAVE AN APPROXIMATE LOCATION BASED ON INFORMATION FROM DAN MOGEN, EI, CFM FROM THE STORMWATER ENGINEERING AND DEVELOPMENT REVIEW DIVISION FOR THE CITY OF FORT COLLINS, COLORADO. EXISTING 3/4" WATER STUB (SEE NOTE BELOW) EXISTING 4" IRRIGATION SERVICE (SEE NOTE BELOW) EXISTING 6" CIP WATER MAIN (SEE NOTE BELOW) EXISTING 15" DIP STORMWATER PIPE (SEE NOTE BELOW) REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 13. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. 14. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 15. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 16. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 17. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 18. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 19. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 20. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPERS EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 21. ANY PUBLIC IMPROVEMENTS MUST BE DESIGNED AND BUILT IN ACCORDANCE WITH THE LARIMER COUNTY URBAN AREA STREET STANDARDS (LCUASS). 22. ALL FENCES, BARRIERS, POSTS OR OTHER ENCROACHMENTS WITHIN THE PUBLIC RIGHT-OF-WAY ARE ONLY PERMITTED UPON APPROVAL OF AN ENCROACHMENT PERMIT. APPLICATIONS FOR ENCROACHMENT PERMITS SHALL BE MADE TO THE ENGINEERING DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. ENCROACHMENT ITEMS SHALL NOT BE SHOWN ON THE SITE PLAN AS THEY MAY NOT BE APPROVED, NEED TO BE MODIFIED OR MOVED, OR IF THE PERMIT IS REVOKED THEN THE SITE/LANDSCAPE PLAN IS IN NON-COMPLIANCE. 23. WITH REGARDS TO CONSTRUCTION OF THIS SITE, THE PUBLIC RIGHT-OF-WAY SHALL NOT BE USED FOR STAGING OR STORAGE OF MATERIALS OR EQUIPMENT ASSOCIATED WITH THE DEVELOPMENT, NOR SHALL IT BE USED FOR PARKING BY ANY CONTRACTORS, SUBCONTRACTORS, OR OTHER PERSONNEL WORKING FOR OR HIRED BY THE DEVELOPER TO CONSTRUCT THE DEVELOPMENT. THE DEVELOPER WILL NEED TO FIND A LOCATION(S) ON PRIVATE PROPERTY TO ACCOMMODATE ANY NECESSARY STAGING AND/OR PARKING NEEDS ASSOCIATED WITH THE COMPLETION OF THE DEVELOPMENT. 24. TO ASSIST WITH EMERGENCY RESPONSE, SIGNAGE SHOULD BE CLEARLY VISIBLE AT GROUND LEVEL AND AT THE ACCESS LADDER TO INDICATE THE MOST APPROPRIATE ACCESS TO THE VERIZON EQUIPMENT. LEGEND W W SS SS SS F F F GAS GAS GAS GAS GAS OE OE UT UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD SD SD SD E E E UE UE UE OT OT OT EV D O O O U/G U/G OHW OHW STORM SEWER UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING SKYLIGHT HVAC UNIT AC SECURITY CAMERA VENT PIPE VP BOLLARD COMM DISH GROUNDING NOTES: 1. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. 2. ALL GROUNDING DEVICES SHALL BE U.L. APPROVED OR LISTED FOR THEIR INTENDED USE. 3. ALL WIRES SHALL BE AWG THHN/THWN COPPER UNLESS NOTED OTHERWISE. 4. GROUND WIRES SHALL BE #2 AWG BARE SOLID COPPER UNLESS NOTED OTHERWISE. 5. GROUNDING CONNECTIONS SHALL BE EXOTHERMIC ("CADWELDS") TO GROUND RODS, GROUND RING WIRE, AND FENCE POSTS UNLESS NOTED OTHERWISE. CLEAN SURFACES TO SHINY METAL. WHERE GROUND WIRES ARE CADWELDED TO GALVANIZED SURFACES, SPRAY CADWELD WITH GALVANIZED PAINT. 6. GROUNDING CONNECTIONS TO GROUND BARS ARE TO BE TWO-HOLE BRASS MECHANICAL CONNECTORS WITH STAINLESS STEEL HARDWARE (INCLUDING SCREW SET.) CLEAN GROUND BAR TO SHINY METAL AFTER MECHANICAL CONNECTION, TREAT WITH PROTECTIVE ANTIOXIDANT COATING. 7. GROUND CABLE SHIELDS AT BOTH ENDS WITH MANUFACTURER'S GROUNDING KITS. 8. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM 8" RADIUS. 9. PRIOR TO INSTALLING LUGS ON GROUND WIRES, APPLY THOMAS & BETTS KOPR-SHIELD (TM OF JET LUBE, INC.) PRIOR TO BOLTING GROUND WIRE LUGS TO GROUND BARS, APPLY KOPR-SHIELD OR EQUAL. 10. PREPARE ALL BONDING SURFACES FOR GROUNDING CONNECTIONS BY REMOVING ALL PAINT AND CORROSION DOWN TO SHINY METAL. FOLLOWING CONNECTION, APPLY APPROPRIATE ANTI-OXIDIZATION PAINT. ELECTRICAL NOTES: 1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING BID. ANY QUESTIONS ARISING DURING THE BID PERIOD IN REGARDS TO THE CONTRACTORS FUNCTIONS, THE SCOPE OF WORK, OR ANY OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. 2. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE COORDINATED WITH FIELD CONDITIONS PRIOR TO ROUGH-IN. 3. THE CONDUIT RUNS AS SHOWN ON THE PLANS ARE APPROXIMATE. EXACT LOCATION AND ROUTING SHALL BE PER EXISTING FIELD CONDITIONS. 4. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR REQUIRED BY NEC. 5. ALL CONDUITS SHALL BE MET WITH BENDS MADE IN ACCORDANCE WITH NEC CHAPTER 9, TABLE #2. NO RIGHT ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM INSIDE SWEEPS FOR ALL CONDUITS 2" OR LARGER. 6. ALL CONDUIT TERMINATIONS SHALL BE PROVIDED WITH PLASTIC THROAT INSULATING GROUNDING BUSHINGS. 7. ALL WIRE SHALL BE TYPE THHN/THWN, SOLID, ANNEALED COPPER UP TO SIZE #10 AWG (#8 AND LARGER SHALL BE CONCENTRIC STRANDED) 75° C (167° F), 98% CONDUCTIVITY, MINIMUM #12. 8. ALL WIRES SHALL BE TAGGED AT ALL PULL BOXES, J-BOXES, EQUIPMENT BOXES AND CABINETS WITH APPROVED PLASTIC TAGS, ACTION CRAFT, BRADY, OR APPROVED EQUAL. 9. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL. 10. CONDUIT ROUGH-IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION TO CONFLICTS. VERIFY WITH MECHANICAL CONTRACTOR AND COMPLY AS REQUIRED. 11. ALL PANEL DIRECTORIES SHALL BE TYPEWRITTEN NOT HAND WRITTEN. 12. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC. THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL DISCONNECT SWITCHES, STARTERS, AND EQUIPMENT CABINETS. 13. THE CONTRACTOR SHALL PREPARE AS-BUILT DRAWINGS, DOCUMENT ANY AND ALL WIRING AND EQUIPMENT CONDITIONS AND CHANGES WHILE COMPLETING THIS CONTRACT. SUBMIT AT SUBSTANTIAL COMPLETION. 14. ALL DISCONNECT SWITCHES AND OTHER CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED LAMICOID NAMEPLATES INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM (NO EXCEPTIONS.) 15. ALL ELECTRICAL DEVICES AND INSTALLATIONS OF THE DEVICES SHALL COMPLY WITH AMERICANS WITH DISABILITIES ACT (ADA) AS ADOPTED BY THE APPLICABLE STATE. 16. PROVIDE CORE DRILLING AS NECESSARY FOR PENETRATIONS OR RISERS THROUGH BUILDING. DO NOT PENETRATE STRUCTURAL MEMBERS WITHOUT CONSTRUCTION MANAGER'S APPROVAL. SLEEVES AND/OR PENETRATIONS IN FIRE RATED CONSTRUCTION SHALL BE PACKED WITH FIRE RATED MATERIAL WHICH SHALL MAINTAIN THE FIRE RATING OF THE WALL OR STRUCTURE. FILL FOR FLOOR PENETRATIONS SHALL PREVENT PASSAGE OF WATER, SMOKE, FIRE AND FUMES. ALL MATERIAL SHALL BE UL APPROVED FOR THIS PURPOSE. 17. ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT (NEW AND EXISTING) SHALL BE FIELD VERIFIED WITH THE OWNER'S REPRESENTATIVE AND EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN OF CONDUIT AND WIRE. ALL EQUIPMENT SHALL BE PROPERLY CONNECTED ACCORDING TO THE NAMEPLATE DATA FURNISHED ON THE EQUIPMENT (THE DESIGN OF THESE PLANS ARE BASED UPON BEST AVAILABLE INFORMATION AT THE TIME OF DESIGN AND SOME EQUIPMENT CHARACTERISTICS MAY VARY FROM DESIGN AS SHOWN ON THESE DRAWINGS). LOCATION OF ALL OUTLET, BOXES, ETC., AND THE TYPE OF CONNECTION (PLUG OR DIRECT) SHALL BE CONFIRMED WITH THE OWNER'S REPRESENTATIVE PRIOR TO ROUGH-IN. TREE PROTECTION NOTES: 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3. ALL PROTECTED AND EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POST STAKES, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (1/2) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION LAND OR CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREA BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE(OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW. TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. 10. REPLACEMENT: ANY LANDSCAPE ELEMENT THAT DIES, OR IS OTHERWISE REMOVED, SHALL BE PROMPTLY REPLACED IN ACCORDANCE WITH THE REQUIREMENTS OF THESE PLANS. WEST JORDAN, UT 84088 PH: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720-279-8973 Z-1 C-1 C-2 C-3 SITE PLAN EXISTING ELEVATION PROPOSED ELEVATION CONSTRUCTION DETAILS Z-2 ENLARGED SITE PLAN PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 9656 S. PROSPERITY RD. WEST JORDAN, UT 84088 CONTACT: BRANDON KISER PHONE: 801-260-8700 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: KENT MCDERMOTT EMAIL: KENT.MCDERMOTT@VERIZONWIRELESS.COM AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS .COM RF ENGINEER PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION LEGAL DESCRIPTION POUDRE RIVER PUBLIC LIBRARY DISTRICT CONTACT: MARK HUBER PHONE: 970-221-6662 301 E. OLIVE ST FORT COLLINS, CO 80524 GN-1 GENERAL NOTES PH-1 PHOTOSIMULATIONS REVISION SCHEDULE REV DATE BY DESCRIPTION 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 097-17-0097 DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 19 SITE NAME: FTC OLD TOWN LIBRARY SITE ADDRESS: 201 PETERSON ST. FORT COLLINS, CO 80524 JURISDICTION: CITY OF FORT COLLINS 0 05-07-18 RPH PRELIM CONSTRUCTION DWGs SHEET NUMBER: MIKKO P. AHOLA, P.E. COLORADO PROFESSIONAL ENGINEER LICENSE #33495 (EXP. 10/31/2019) 1 07-26-18 RPH REVISED CDs 2 08-10-18 RPH REVISED CDs 3 09-07-18 RPH REVISED CDs 4 11-09-18 RPH REVISED CDs 5 11-12-18 LCW REVISED CDs 6 12-11-18 RPH REVISED CDs A PORTION OF BLOCK 142, TOWN OF FORT COLLINS, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. C-4 CONSTRUCTION DETAILS (CONTINUED) C-5 A-1 ANTENNA PLAN E-1 ELECTRICAL PLAN E-2 ONE-LINE DIAGRAM & ELEVATION E-3 PANEL SCHEDULE G-1 GROUNDING PLAN G-2 GROUNDING DETAILS CONSTRUCTION DETAILS (CONTINUED) U-1 UTILITY PLAN PROPOSED LEASE AREA 485 S.F. CENTERLINE SOLUTIONS 16035 TABLE MOUNTAIN PARKWAY GOLDEN, CO 80403 CONTACT: JEN DANIELS PHONE: 303-550-4820 C-6 EME DETAILS LS-1 SITE SURVEY LS-2 SITE SURVEY SURVEY TM-1 TREE MITIGATION PLAN