HomeMy WebLinkAboutFTC EAST DALE WTE VERIZON - BDR180016 - SUBMITTAL DOCUMENTS - ROUND 3 - PLANSSITE NAME:
SITE ADDRESS:
FTC EAST DALE
901 RIVERSIDE AVE.
FORT COLLINS, CO 80524
LARIMER COUNTY
DRAWING INDEX
T1 TITLE SHEET
LS1 LAND SURVEY
LS2
GENERAL CONTRACTOR NOTE PROJECT TEAM
APPROVAL BLOCK
TITLE SIGNATURE DATE
OWNER
ENGINEER
PROJECT MANAGER
ACKNOWLEDGEMENT OR "SIGN-OFF" BY PARTIES TO THE CONSTRUCTION
DRAWINGS DOES NOT CONSTITUTE ALTERATION OF THE LEASE TERMS.
PROPERTY OWNER:
HOUSKA AUTOMOTIVE
CONTACT: DENNIS HOUSKA
PHONE: 970.482.0156
VICINITY MAP
PROJECT DESCRIPTION
NEW UNOCCUPIED CONCEALED TELECOMMUNICATIONS FACILITIES
CONSISTING OF NEW ANTENNAS BEHIND A NEW VERIZON CONCEALMENT
SCREEN WALL ENCLOSURE ON ROOF OF EX. BUILDING, WITH EQUIPMENT ON
A NEW ELEVATED PLATFORM ON ROOF CONCEALED BEHIND LOUVER
SCREEN
PROJECT DATA
JURISDICTION:
PARCEL NUMBER:
ZONING DESIGNATION:
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
FULLY SPRINKLERED:
NO. OF STORIES:
GOVERNING CODES IF APPLICABLE:
2015 IBC, 2015 IECC, 2015 IFC, 2015 IMC, 2015 IPC, 2015 IRBC, 2017 NEC.
A.D.A. COMPLIANCE:
NOT REQUIRED PER IBC 1103.2.9
-
-
-
-
-
-
-
CITY OF FT. COLLINS
971313002
XXXX
U
V-B
NO
TWO
LEGAL DESCRIPTION:
LOT 2, HOUSKA MINOR SUBDIVISION, CITY OF FT. COLLINS, COUNTY OF
LARIMER, STATE OF COLORADO. EXCEPT THAT PORTION OF THE LOT 2
CONVEYED TO THE CITY OF FORT COLLINS IN DEED OF DEDICATION
RECORDED MAY 10, 2012 AT RECEPTION NO. 20120030809.
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
PH1
PHOTOSIMULATIONS
NORTH &
SOUTHEAST VIEWS
2 NEW VIEW FROM THE NORTH
1 EXISTING VIEW FROM THE NORTH
4 NEW VIEW FROM THE SOUTHEAST
3 EXISTING VIEW FROM THE SOUTHEAST
NEW VZW ANTENNAS CONCEALED
BEHIND RF TRANSPARENT SCREEN
WALLS (PAINTED TO MATCH
EXISTING BUILDING)
NEW VZW ANTENNAS CONCEALED
BEHIND RF TRANSPARENT SCREEN
WALLS (PAINTED TO MATCH
EXISTING BUILDING)
NEW VZW EQUIPMENT ON PLATFORM
CONCEALED BEHIND LOUVER SCREEN WALLS
(PAINTED TO MATCH EXISTING BUILDING)
NEW VZW EQUIPMENT ON PLATFORM
CONCEALED BEHIND LOUVER SCREEN WALLS
(PAINTED TO MATCH EXISTING BUILDING)
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
PH2
PHOTOSIMULATIONS
EAST VIEW
2 NEW VIEW FROM THE EAST
1 EXISTING VIEW FROM THE EAST
4 NOT USED
3 NOT USED
NEW VZW ANTENNAS CONCEALED
BEHIND RF TRANSPARENT SCREEN
WALLS (PAINTED TO MATCH
EXISTING BUILDING)
NEW VZW EQUIPMENT ON PLATFORM
CONCEALED BEHIND LOUVER SCREEN WALLS
(PAINTED TO MATCH EXISTING BUILDING)
VZW
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
Z1
OVERALL
SITE PLAN
1 OVERALL SITE PLAN
NEW VZW
UTILITY
EASEMENT
NEW VZW
ACCESS
EASEMENT
NEW VZW
LEASE AREA,
(140 S.F.)
SCALE: 1" = 30'-0" (11X17) 0' 15' 30' 60'
SCALE: 1" = 15'-0" (24X36)
LEASE LEGEND
EX. PROPERTY LINE,
TYP. (SEE LS1)
NEW VZW U/G FIBER RUN
(INSIDE EASEMENT)
EX. BUILDING
EX. PARKING
LOT
EX. PROPERTY LINE,
TYP. (SEE LS1)
NEW VZW LEASE
AREA (140 S.F.) EX. PARKING
LOT
NEW VZW CAGED ACCESS LADDER
WITH HINGED LOCKING SECURITY
GUARD, TO LOWER LEVEL ROOF
(PAINT GREEN TO MATCH EX. TRIM)
VZW
1 ENLARGED SITE PLAN 2 EQUIPMENT PLAN
3 ANTENNA DETAIL
SCALE: 1/4" = 1'-0"
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
Z2
ENLARGED SITE PLAN
EQUIPMENT PLAN &
ANTENNA DETAIL
SCALE: 1" = 20'-0" (11X17) 0' 10' 20' 40'
SCALE: 1" = 10'-0" (24X36)
SCALE: 3/16" = 1'-0" (11X17) 0' 10'
SCALE: 3/8" = 1'-0" (24X36)
5'
EX. FENCE
NEW VZW CONCEALMENT
SCREEN WALL W/ FRP
PANELS FINISHED TO MATCH
EX. BUILDING COLOR
(2) NEW VZW
HYBRID CABLES
Y SECTOR
AZIMUTH 110°
X SECTOR
AZIMUTH 350°
(4) NEW VZW ANTENNAS,
TYP. (PER SECTOR)
(8) NEW VZW RRHs TYP.
(PER SECTOR)
3'-0"
TYP.
DELTA SECTOR
AZIMUTH 230°
(2) NEW VZW CABINETS MOUNTED
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
1 SOUTHEAST ELEVATION
2 NORTHEAST ELEVATION
SCALE: 3/32" = 1'-0" (11X17) 0' 20'
SCALE: 3/16" = 1'-0" (24X36)
10'
SCALE: 3/32" = 1'-0" (11X17) 0' 20'
SCALE: 3/16" = 1'-0" (24X36)
10'
T.O. PARAPET
ELEV. 30'-0"
EX. GRADE
ELEV. 0'-0" (4963'-0)
T.O. PARAPET
ELEV. 30'-0"
Z3.1
SOUTHEAST &
NORTHEAST
ELEVATIONS
T.O. SCREEN WALL
ELEV. 40'-0"
T.O. SCREEN WALL
ELEV. 40'-0"
NEW VZW ANTENNAS CONCEALED BEHIND RF
TRANSPARENT SCREEN WALL, (PAINTED TO MATCH
EX. BUILDING 8X8 FLAT FACE CMU, AND ADD HEAVY
STUCCO TEXTURE TO SIMULATE CONCRETE. JOINTS
BETWEEN FACES TO BE UNTEXTURED AND PAINTED
WHITE TO MATCH EX. BUILDING MORTAR JOINTS)
NEW VZW CAGED ROOF
ACCESS LADDER (PAINT
GREEN TO MATCH EX.
TRIM)
NEW VZW CAGED ROOF
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
1 NORTHWEST ELEVATION
2 SOUTHWEST ELEVATION Z3.2
NORTHWEST &
SOUTHWEST
ELEVATIONS
SCALE: 3/32" = 1'-0" (11X17) 0' 20'
SCALE: 3/16" = 1'-0" (24X36)
10'
SCALE: 3/32" = 1'-0" (11X17) 0' 20'
SCALE: 3/16" = 1'-0" (24X36)
10'
T.O. PARAPET
ELEV. 30'-0"
T.O. SCREEN WALL
ELEV. 40'-0"
T.O. PARAPET
ELEV. 30'-0"
T.O. SCREEN WALL
ELEV. 40'-0"
NEW VZW ROOF ACCESS LADDER
W/ HINGED BOTTOM SECURITY
PANEL W/ KNOX LOCK BOX
(PAINT GREEN TO MATCH EX.
TRIM)
NEW VZW LADDER TO UPPER
LEVEL ROOF W/ SECURITY PANEL
AND KNOX LOCK BOX (PAINT
GREEN TO MATCH EX. TRIM)
NEW VZW ROOF ACCESS LADDER W/ HINGED
BOTTOM SECURITY PANEL, W/ KNOX LOCK BOX
(PAINT GREEN TO MATCH EX. TRIM)
NEW VZW WALL
MOUNTED CONDUIT
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
PRELIMINARY -
NOT FOR
CONSTRUCTION
1 RF SIGNAGE
SCALE: 1" = 10'-0"
2 RF SAFETY SIGNAGE DETAIL
SCALE: NTS
NEW VZW RF SAFETY SIGNAGE
ON BOTTOM OF LOWER ROOF
ACCESS LADDER EX. BUILDING
LOWER ROOFTOP
NEW VZW RF SAFETY
SIGNAGE ON ALL FOUR
FACES OF THE ANTENNA
SCREEN
EX. ROOFTOP
ACCESS HATCH
A RF INFORMATION SIGNAGE
GENERAL RADIO FREQUENCY (RF)
SAFETY GUIDELINES
NOTICE
Until ALL applicable antennas have been deactivated, please observe
the following:
Obey all posted signs.
Assume all antennas are transmitting.
Do not touch any antenna.
Do not stand in front of any antenna.
Do not walk in front of any antenna.
Do not walk beyond any signs, barriers, or visual markers towards
any antenna.
Contact antenna owner or property owner if there are any questions
or concerns.
verizon
VZW
1 UTILITY PLAN 3 SITE SPECIFIC UTILITY NOTES
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
UC1
UTILITY
COORDINATION
PLAN
SCALE: 1" = 30'-0" (11X17) 0' 15' 30' 60'
SCALE: 1" = 15'-0" (24X36)
NEW VZW
UTILITY
EASEMENT
NEW VZW
ACCESS
EASEMENT
NEW VZW
LEASE AREA,
(248 S.F.)
LEASE LEGEND
2 EXISTING SITE CONDITIONS - LOOKING NORTH TO SITE
POWER COORDINATION NOTES:
CITY OF FT. COLLINS LIGHT & POWER
T.B.D.
FIBER COORDINATION NOTES:
CONTACT: TBD
-T.B.D.
EX. PROPERTY LINE,
TYP. (SEE LS1)
NEW VZW U/G FIBER RUN
(INSIDE EASEMENT)
EX. BUILDING
EX. PARKING
LOT
EX. PROPERTY LINE,
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
FCN1
CONSTRUCTION
NOTES
PRELIMINARY -
NOT FOR
CONSTRUCTION
General Notes (City of Fort Collins and Larimer County)
Appendix E-1-FC/Lar
1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and
specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations.
Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive
standard shall apply. All work shall be inspected and approved by the Local Entity.
2. All references to any published standards shall refer to the latest revision of said standard, unless specifically
stated otherwise.
4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility
to the Local Entity, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and
approval of these plans by the Local Entity Engineer shall not relieve the engineer who has prepared these plans of all
such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and
indemnify the Local Entity, and its officers and employees, from and against all liabilities, claims, and demands which
may arise from any errors and omissions contained in these plans.
5. All sanitary sewer, storm sewer, and water line construction, as well as power and other “dry” utility
installations, shall conform to the Local Entity standards and specifications current at the date of approval of the plans
by the Local Entity Engineer.
6. The type, size, location and number of all known underground utilities are approximate when shown on the
drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities
along the route of the work before commencing new construction. The Developer shall be responsible for unknown
underground utilities.
7. The Engineer shall contact the Utility Notification Center of Colorado (UNCC) at 1- 800-922-1987, at least 2
working days prior to beginning excavation or grading, to have all registered utility locations marked. Other
unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective
representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the
responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on
these plans.
DESIGN NOTES
1.0 GENERAL CONDITIONS
1.1 DESIGN AND CONSTRUCTION OF ALL WORK SHALL CONFORM TO THE IBC 2015 EDITION AND ALL
OTHER APPLICABLE STATE CODES, ORDINANCES, AND REGULATIONS. IN CASE OF CONFLICT
BETWEEN THE CODES, STANDARDS, AND REGULATIONS. SPECIFICATIONS, GENERAL NOTES AND/OR
MANUFACTURER'S REQUIREMENTS. USE THE MOST STRINGENT PROVISION.
1.2 IT IS THE EXPRESS INTENT OF THE PARTIES INVOLVED IN THIS PROJECT THAT THE CONTRACTOR
OR SUBCONTRACTOR OR INDEPENDENT CONTRACTOR OR THEIR RESPECTIVE EMPLOYEES SHALL
EXCULPATE THE ARCHITECT, THE ENGINEER, THE CONSTRUCTION MANAGER, THE OWNER, AND
THEIR AGENTS, FROM ANY LIABILITY WHATSOEVER AND HOLD THEM HARMLESS AGAINST LOSS,
DAMAGES, LIABILITY OR ANY EXPENSE ARISING IN ANY MATTER FROM THE WRONGFUL OR
NEGLIGENT ACT, OR FAILURE TO CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT
DOCUMENTS, OR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR
PROCEDURES OR FAILURE TO CONFORM TO THE STATE SCAFFOLDING ACT IN CONNECTION WITH
THE WORK.
1.3 DESIGN LOADS ARE:
WIND SPEED 100 MPH 3 SEC
SNOW LOAD 30 PSF
GENERAL CONSTRUCTION NOTES:
GENERAL CONSTRUCTION
1. FOR THE PURPOSE OF CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL
APPLY:
GENERAL CONTRACTOR: T.B.D.
CONTRACTOR: T.B.D.
OWNER: VERIZON WIRELESS
2. ALL SITE WORK SHALL BE COMPLETED AS INDICATED ON THE DRAWINGS AND VERIZON
WIRELESS PROJECT SPECIFICATIONS.
3. GENERAL CONTRACTOR SHALL VISIT THE SITE AND SHALL FAMILIARIZE HIMSELF WITH ALL
CONDITIONS AFFECTING THE PROPOSED WORK AND SHALL MAKE PROVISIONS. GENERAL
CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF WITH ALL CONTRACT
DOCUMENTS, FIELD CONDITIONS, DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE
ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE
COMMENCEMENT OF WORK.
4. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL
APPLICABLE CODES, REGULATIONS, AND ORDINANCES. GENERAL CONTRACTOR SHALL ISSUE
ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES,
REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE
PERFORMANCE OF WORK.
5. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY
COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES, AND
APPLICABLE REGULATIONS.
6. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS,
EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS
AS INDICATED ON THE DRAWINGS.
7. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A DIAGRAMMATIC
OUTLINE ONLY UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ARE TO FINISH SURFACES
UNLESS OTHERWISE NOTED. SPACING BETWEEN EQUIPMENT IS THE MINIMUM REQUIRED
CLEARANCE. THEREFORE, IT IS CRITICAL TO FIELD VERIFY DIMENSIONS, SHOULD THERE BE
ANY QUESTIONS REGARDING THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR OBTAINING A CLARIFICATION FROM THE ENGINEER PRIOR TO PROCEEDING
WITH THE WORK. DETAILS ARE INTENDED TO SHOW DESIGN INTENT. MODIFICATIONS MAY BE
REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS AND SUCH MODIFICATIONS SHALL BE
INCLUDED AS PART OF WORK AND PREPARED BY THE ENGINEER PRIOR TO PROCEEDING WITH
WORK.
8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE.
9. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE
CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY
THE ENGINEER PRIOR TO PROCEEDING.
GENERAL CONSTRUCTION NOTES CONTINUED:
COAXIAL CABLE NOTES
63. TYPES AND SIZES OF THE ANTENNA CABLE ARE BASED ON ESTIMATED LENGTHS. PRIOR TO
ORDERING CABLE, CONTRACTOR SHALL VERIFY ACTUAL LENGTH BASED ON CONSTRUCTION
LAYOUT AND NOTIFY THE PROJECT MANAGER IF ACTUAL LENGTHS EXCEED ESTIMATED
LENGTHS.
64. CONTRACTOR SHALL VERIFY THE DOWN-TILT OF EACH ANTENNA WITH A DIGITAL LEVEL.
65. CONTRACTOR SHALL CONFIRM COAX COLOR CODING PRIOR TO CONSTRUCTION.
66. ALL JUMPERS TO THE ANTENNAS FROM THE MAIN TRANSMISSION LINE SHALL BE 1/2" DIA. LDF
AND SHALL NOT EXCEED 6'-0".
67. ALL COAXIAL CABLE SHALL BE SECURED TO THE DESIGNED SUPPORT STRUCTURE, IN AN
APPROVED MANNER, AT DISTANCES NOT TO EXCEED 4'-0" OC.
68. CONTRACTOR SHALL FOLLOW ALL MANUFACTURER'S RECOMMENDATIONS REGARDING BOTH
THE INSTALLATION AND GROUNDING OF ALL COAXIAL CABLES, CONNECTORS, ANTENNAS, AND
ALL OTHER EQUIPMENT.
69. CONTRACTOR SHALL WEATHERPROOF ALL ANTENNA CONNECTORS WITH SELF
AMALGAMATING TAPE. WEATHERPROOFING SHALL BE COMPLETED IN STRICT ACCORDANCE
WITH VERIZON WIRELESS STANDARDS.
GENERAL CABLE AND EQUIPMENT NOTES
70. CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ANTENNA, TMAS, DIPLEXERS, AND COAX
CONFIGURATION, MAKE AND MODELS PRIOR TO INSTALLATION.
71. ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER
TOWER MANUFACTURER'S RECOMMENDATIONS.
72. CONTRACTOR SHALL REFERENCE THE TOWER STRUCTURAL ANALYSIS/DESIGN DRAWINGS
FOR DIRECTIONS ON CABLE DISTRIBUTION/ROUTING.
73. ALL OUTDOOR RF CONNECTORS/CONNECTIONS SHALL BE WEATHERPROOFED, EXCEPT THE
RET CONNECTORS, USING BUTYL TAPE AFTER INSTALLATION AND FINAL CONNECTIONS ARE
MADE. BUTYL TAPE SHALL HAVE A MINIMUM OF ONE-HALF TAPE WIDTH OVERLAP ON EACH TURN
AND EACH LAYER SHALL BE WRAPPED THREE TIMES. WEATHERPROOFING SHALL BE SMOOTH
WITHOUT BUCKLING. BUTYL BLEEDING IS NOT ALLOWED. SELF BONDING TAPE AND PLASTIC
ENCLOSURES ALSO PERMITTED PER ATT-002-290-041 SECTION 7.
74. IF REQUIRED TO PAINT ANTENNAS AND/OR COAX:
A. TEMPERATURE SHALL BE ABOVE 50° F.
B. PAINT COLOR MUST BE APPROVED BY BUILDING OWNER/LANDLORD.
C. FOR REGULATED TOWERS, FAA/FCC APPROVED PAINT IS REQUIRED.
D. DO NOT PAINT OVER COLOR CODING OR ON EQUIPMENT MODEL NUMBERS.
75. ALL CABLES SHALL BE GROUNDED WITH COAXIAL CABLE GROUND KITS. FOLLOW THE
MANUFACTURER'S RECOMMENDATIONS.
A. GROUNDING AT THE ANTENNA LEVEL.
B. GROUNDING AT MID LEVEL, TOWERS WHICH ARE OVER 200'-0", ADDITIONAL CABLE
GROUNDING REQUIRED.
C. GROUNDING AT BASE OF TOWER PRIOR TO TURNING HORIZONTAL.
D. GROUNDING OUTSIDE THE EQUIPMENT SHELTER AT ENTRY PORT.
E. GROUNDING INSIDE THE EQUIPMENT SHELTER AT THE ENTRY PORT.
76. ALL PROPOSED GROUND BAR DOWNLEADS ARE TO BE TERMINATED TO THE EXISTING
ADJACENT GROUND BAR DOWNLEADS A MINIMUM DISTANCE OF 4'-0" BELOW GROUND BAR.
TERMINATIONS MAY BE EXOTHERMIC OR COMPRESSION.
77. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE ANTENNA AND THE COAX
CONFIGURATION IS THE CORRECT MAKE AND MODELS, PRIOR TO INSTALLATION.
78. ALL CONNECTIONS FOR HANGERS, SUPPORTS, BRACING, ETC. SHALL BE INSTALLED PER
TOWER MANUFACTURER'S SPECIFICATION & RECOMMENDATIONS.
GENERAL SITE WORK & DRAINAGE NOTES:
PART 1 - GENERAL
CLEARING, GRUBBING, STRIPPING, EROSION CONTROL, SURVEY, LAYOUT, SUBGRADE
PREPARATION AND FINISH GRADING AS REQUIRED TO COMPLETE THE PROPOSED WORK SHOWN IN
THESE PLANS.
1.1 REFERENCES:
A. DOT (STATE DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY
CONSTRUCTION-CURRENT EDITION).
B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS).
3.4 TRENCH BACKFILL:
A. PROVIDE GRANULAR BEDDING MATERIAL IN ACCORDANCE WITH THE DRAWINGS AND THE
UTILITY REQUIREMENTS.
B. NOTIFY THE GENERAL CONTRACTOR 24 HOURS IN ADVANCE OF BACKFILLING.
C. CONDUCT UTILITY CHECK TESTS BEFORE BACKFILLING. BACKFILL AND COMPACT TRENCH
BEFORE ACCEPTANCE TESTING.
D. PLACE GRANULAR TRENCH BACKFILL UNIFORMLY ON BOTH SIDES OF THE CONDUITS IN
6-INCH UNCOMPACTED LIFTS UNTIL 12 INCHES OVER THE CONDUITS. SOLIDLY RAM AND
TAMP BACKFILL INTO SPACE AROUND CONDUITS.
E. PROTECT CONDUIT FROM LATERAL MOVEMENT, IMPACT DAMAGE, OR UNBALANCED
LOADING.
F. ABOVE THE CONDUIT EMBEDMENT ZONE, PLACE AND COMPACT SATISFACTORY BACKFILL
MATERIAL IN 8-INCH MAXIMUM LOOSE THICKNESS LIFTS TO RESTORE THE REQUIRED
FINISHED SURFACE GRADE.
G. COMPACT FINAL TRENCH BACKFILL TO A DENSITY EQUAL TO OR GREATER THAN THAT OF
THE EXISTING UNDISTURBED MATERIAL IMMEDIATELY ADJACENT TO THE TRENCH BUT NO
LESS THAN A MINIMUM OF 95 PERCENT OF THE MAXIMUM DRY DENSITY AS PROVIDED BY
THE STANDARD PROCTOR TEST, ASTM D 698.
3.5 AGGREGATE ACCESS ROAD:
A. CLEAR, GRUB, STRIP AND EXCAVATE FOR THE ACCESS ROAD TO THE LINES AND GRADES
INDICATED ON THE DRAWINGS. SCARIFY TO A DEPTH OF 6 INCHES AND PROOF-ROLL. ALL
HOLES, RUTS, SOFT PLACES AND OTHER DEFECTS SHALL BE CORRECTED.
B. THE ENTIRE SUBGRADE SHALL BE COMPACTED TO NOT LESS THAN 95 PERCENT OF THE
MAXIMUM DRY DENSITY AS PROVIDED BY THE MODIFIED PROCTOR TEST, ASTM D 1557.
C. AFTER PREPARATION OF THE SUBGRADE IS COMPLETE THE GEOTEXTILE FABRIC (MIRAFI
500XI) SHALL BE INSTALLED TO THE LIMITS INDICATED ON THE DRAWINGS BY ROLLING THE
FABRIC OUT LONGITUDINALLY ALONG THE ROADWAY. THE FABRIC SHALL NOT BE
DRAGGED ACROSS THE SUBGRADE. PLACE THE ENTIRE ROLL IN A SINGLE OPERATION,
ROLLING OUT AS SMOOTHLY AS POSSIBLE.
1. OVERLAPS PARALLEL TO THE ROADWAY WILL BE PERMITTED AT THE CENTERLINE AND AT
LOCATIONS BEYOND THE ROADWAY SURFACE WIDTH (I.E. WITHIN THE SHOULDER WIDTH)
ONLY. NO LONGITUDINAL OVERLAPS SHALL BE LOCATED BETWEEN THE CENTERLINE AND
THE SHOULDER. PARALLEL OVERLAPS SHALL BE A MINIMUM OF 3 FEET WIDE.
2. TRANSVERSE (PERPENDICULAR TO THE ROADWAY) OVERLAPS AT THE END OF A ROLL
SHALL OVERLAP IN THE DIRECTION OF THE AGGREGATE PLACEMENT (PREVIOUS ROLL ON
TOP) AND SHALL HAVE A MINIMUM LENGTH OF 3 FEET.
3. ALL OVERLAPS SHALL BE PINNED WITH STAPLES OR NAILS A MINIMUM OF 10 INCHES LONG
TO INSURE POSITIONING DURING PLACEMENT OF AGGREGATE. PIN LONGITUDINAL SEAMS
AT 25 FOOT CENTERS AND TRANSVERSE SEAMS EVERY 5 FEET.
D. THE AGGREGATE BASE AND SURFACE COURSES SHALL BE CONSTRUCTED IN LAYERS NOT
MORE THAN 4 INCH (COMPACTED) THICKNESS. AGGREGATE TO BE PLACED ON
GEOTEXTILE FABRIC SHALL BE END-DUMPED ON THE FABRIC FROM THE FREE END OF THE
FABRIC OR OVER PREVIOUSLY PLACED AGGREGATE. THE FIRST LIFT SHALL BE BLADED
DOWN TO A THICKNESS OF 8 INCHES PRIOR TO COMPACTION. AT NO TIME SHALL
EQUIPMENT, EITHER TRANSPORTING THE AGGREGATE OR GRADING THE AGGREGATE, BE
PERMITTED ON THE ROADWAY WITH LESS THAN 4 INCHES OF MATERIAL COVERING THE
FABRIC.
E. THE AGGREGATE SHALL BE IMMEDIATELY COMPACTED TO NOT LESS THAN 95 PERCENT OF
THE MAXIMUM DRY DENSITY AS PROVIDED BY THE MODIFIED PROCTOR TEST, ASTM D 1557
WITH A TAMPING ROLLER, OR WITH A PNEUMATIC-TIRED ROLLER, OR WITH A VIBRATORY
MACHINE OR ANY COMBINATION OF THE ABOVE. THE TOP LAYER SHALL BE GIVEN A FINAL
ROLLING WITH A THREE-WHEEL OR TANDEM ROLLER.
3.6 FINISH GRADING:
A. PERFORM ALL GRADING TO PROVIDE POSITIVE DRAINAGE AWAY FROM STRUCTURES AND
SMOOTH, EVEN SURFACE DRAINAGE OF THE ENTIRE AREA WITHIN THE LIMITS OF
CONSTRUCTION. GRADING SHALL BE COMPATIBLE WITH ALL SURROUNDING TOPOGRAPHY
AND STRUCTURES.
B. UTILIZE SATISFACTORY FILL MATERIAL RESULTING FROM THE EXCAVATION WORK IN THE
CONSTRUCTION OF FILLS, EMBANKMENTS AND FOR REPLACEMENT OF REMOVED
UNSUITABLE MATERIALS.
3.6 CURING:
A. FRESHLY DEPOSITED CONCRETE SHALL BE PROTECTED FROM PREMATURE DRYING AND
EXCESSIVELY HOT AND COLD TEMPERATURES AND SHALL BE MAINTAINED WITH MINIMUM
MOISTURE LOSS AT A RELATIVELY CONSTANT TEMPERATURE FOR A PERIOD OF TIME
NECESSARY FOR THE HYDRATION OF THE CEMENT AND PROPER HARDENING OF THE
CONCRETE.
B. CONCRETE SHALL BE KEPT CONTINUOUSLY MOIST AT LEAST OVERNIGHT, IMMEDIATELY
FOLLOWING THE INITIAL CURING. BEFORE THE CONCRETE HAS DRIED. ADDITIONAL
CURING SHALL BE ACCOMPLISHED BY ONE OF THE FOLLOWING MATERIALS OR METHODS:
1. PONDING OR CONTINUOUS SPRINKLING.
2. ABSORPTIVE MAT OR FABRIC KEPT CONTINUOUSLY WET.
3. NON-ABSORPTIVE FILM (POLYETHYLENE) OVER PREVIOUSLY SPRINKLED SURFACE.
4. SAND OR OTHER COVERING KEPT CONTINUOUSLY WET.
5. CONTINUOUS STEAM (NOT EXCEEDING 150 F) OR VAPOR MIST BATH.
6. SPRAYED- ON CURING COMPOUND APPLIED IN TWO COATS, SPRAYED IN PERPENDICULAR
DIRECTION
C. THE FINAL CURING SHALL CONTINUE UNTIL THE CUMULATIVE NUMBER OF DAYS OR
FRACTION THEREOF, NOT NECESSARILY CONSECUTIVE, DURING WHICH TEMPERATURE OF
THE AIR IN CONTACT WITH CONCRETE IS ABOVE 50F HAS TOTALED SEVEN (7) DAYS.
CONCRETE SHALL NOT BE PERMITTED TO FREEZE DURING THE CURING PERIOD. RAPID
DRYING AT THE END OF THE CURING PERIOD SHALL BE PREVENTED.
GENERAL FIBER REINFORCED PLASTIC NOTES:
1.1 ALL FRP MATERIAL SHALL BE EXTREN SERIES 500 OR EQUIV.
1.2 ALL ADHESIVE SHALL BE PLEXUS METHACRYLATE ADHESIVE OR EQUIV.
1.3 ALL FRP CONNECTIONS SHALL BE FULL BONDED EACH SIDE
WITH 3
8" PLATE AND MINIMUM (2)
3
8" TAPERED FLAT HEAD FRP SCREWS PER MEMBER.
1.4 ALL PANELS SHALL BE FULL BONDED W/ 3
8" PAN HEAD FRP SCREWS AT 12" O.C.
GENERAL STRUCTURAL STEEL NOTES:
PART 1 - GENERAL
1.1 SCOPE:
A. PROVIDE FABRICATION AND ERECTION OF STRUCTURAL STEEL AND OTHER ITEMS AS
SHOWN ON THE DRAWINGS OR REQUIRED BY OTHER SECTIONS OF THESE
SPECIFICATIONS.
1.2 REFERENCES:
A. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC). MANUAL OF STEEL
CONSTRUCTION, ALLOWABLE STRESS DESIGN (ASD).
B. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM).
ASTM A36: STRUCTURAL STEEL
ASTM A53: PIPE, STEEL BLACK AND HOT DIPPED, ZINC-COATED WELDED AND SEAMLESS.
ASTM A108: STEEL BARS, CARBON, COLD FINISHED, STANDARD QUALITY.
ASTM A123: ZINC (HOT-DIPPED GALVANIZED) COATING ON IRON AND STEEL PRODUCTS.
ASTM A307: CARBON STEEL BOLTS AND STUDS, 60,000 P.S.I. TENSILE STRENGTH.
ASTM A325: HIGH-STRENGTH BOLT FOR STRUCTURAL STEEL JOINTS.
ASTM A490: HEAT-TREATED, STRUCTURAL STEEL BOLTS, 150 (KSI) (1035MPA) TENSILE
STRENGTH.
ASTM A500: COLD-FORMED WELDED AND SEAMLESS CARBON STEEL STRUCTURAL TUBING
IN ROUNDS AND SHAPES.
ASTM A563: CARBON AND ALLOY STEEL NUTS.
ASTM B695: COATINGS OF ZINC MECHANICALLY DEPOSITED ON IRON AND STEEL.
ASTM F436: HARDENED STEEL WASHERS.
ASTM F959: COMPRESSIBLE-WASHER-TYPE DIRECT TENSION INDICATOR FOR USE WITH
STRUCTURAL FASTENERS.
C. AMERICAN WELDING SOCIETY (AWS):
AWS A5.1: COVERED CARBON STEEL ARC WELDING ELECTRODES.
AWS A5.5: LOW ALLOY STEEL COVERED ARC WELDING ELECTRODES.
AWS D1.1: STRUCTURAL WELDING CODE - STEEL.
D. RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS (RCSC): "SPECIFICATIONS FOR
STRUCTURAL JOINTS USING ASTM A325 BOLTS OR ASTM A490 BOLTS." AS ENDORSED BY
AISC.
E. STEEL STRUCTURES PAINTING COUNCIL (SSPC):
SSPC-SP3: POWER TOOL CLEANING.
SSPC-PAINT 11: RED IRON OXIDE, ZINC CHROME, RAW LINSEED OIL OR ALKYD PAINT.
1.3 SUBMITTALS:
A. SUBMIT THE FOLLOWING FOR APPROVAL:
1. FABRICATION AND ERECTION DRAWINGS SHOWING ALL DETAILS, CONNECTIONS,
MATERIAL DESIGNATIONS, AND ALL TOP STEEL ELEVATIONS.
B. WELDERS SHALL BE QUALIFIED AS PRESCRIBED IN AWS D1.1.
PART 2 - PRODUCTS
2.1 STRUCTURAL STEEL:
A. SHAPES, PLATES AND BARS SHALL CONFORM TO ASTM A572. ANGLES SHALL CONFORM TO
ASTM A36.
B. STRUCTURAL TUBING SHALL CONF0RM TO ASTM A500, GRADE B. STEEL PIPE SHALL
CONFORM TO ASTM A53, TYPE E OR S, GRADE B.
2.2 ANCHOR BOLTS:
A. ANCHOR BOLTS SHALL CONFORM TO ASTM A307 WITH HEAVY HEXAGONAL NUTS.
2.3 BOLTS:
A. COMMON (MACHINE) BOLTS SHALL CONFORM TO ASTM A307 GRADE A AND NUTS TO ASTM
A563. ONE COMMON BOLT ASSEMBLY SHALL CONSIST OF A BOLT. A HEAVY HEX NUT AND A
HARDENED WASHER.
B. HIGH-STRENGTH BOLTS SHALL CONFORM TO ASTM A325; ONE HIGH STRENGTH BOLT
ASSEMBLY SHALL CONSIST OF A HEAVY HEX STRUCTURAL BOLT, A HEAVY HEX NUT, A
HARDENED WASHER CONFORMING TO ASTM F436. THE HARDENED WASHER SHALL BE
INSTALLED AGAINST THE ELEMENT TURNED IN TIGHTENING. UNLESS NOTED OTHERWISE
ON THE DRAWINGS, ALL CONNECTIONS SHALL BE BEARING TYPE CONNECTIONS.
2.4 WELDING ELECTRODES:
A. WELDING ELECTRODES SHALL COMPLY WITH AWS D1.1 USING A5.1 OR A5.5 E70XX AND
SHALL BE COMPATIBLE WITH THE WELDING PROCESS SELECTED.
2.5 PRIMER:
A. PRIMER SHALL BE RED OXIDE-CHROMATE PRIMER COMPLYING WITH SSPC PAINT
SPECIFICATION NO. 11.
PART 3 - EXECUTION
3.1 FABRICATION:
A. SHOP FABRICATE AND ASSEMBLY MATERIALS AS SPECIFIED HEREIN.
1. FABRICATE ITEMS OF STRUCTURAL STEEL IN ACCORDANCE WITH THE AISC-ASD
SPECIFICATION, AND AS INDICATED ON THE APPROVED SHOP DRAWINGS.
2. ALL EXPOSED STRUCTURAL STEEL SHALL BE HOT DIP GALVANIZED PER ASTM.
3. PROPERLY MARK AND MATCH-MARK MATERIALS FOR FIELD ASSEMBLY AND FOR
IDENTIFICATION AS TO LOCATION FOR WHICH INTENDED.
4. FABRICATE AND DELIVER IN A SEQUENCE WHICH WILL EXPEDITE ERECTION AND MINIMIZE
FIELD HANDLING OF MATERIALS.
5. WHERE FINISHING IS REQUIRED, COMPLETE THE ASSEMBLY, INCLUDING THE WELDING OF
UNITS, BEFORE START OF FINISHING OPERATIONS.
6. PROVIDE FINISH SURFACE OF MEMBERS EXPOSED IN THE FINAL STRUCTURE FREE FROM
MARKINGS, BURNS, AND OTHER DEFECTS.
B. PROVIDE CONNECTIONS AS SPECIFIED HEREIN:
1. PROVIDE BOLTS AND WASHERS OF TYPES AND SIZE REQUIRED FOR COMPLETION OF
FIELD ERECTION. USE 3/4 INCH DIAMETER A325 BOLTS UNLESS NOTED OTHERWISE.
2. INSTALL HIGH STRENGTH THREADED FASTENERS IN ACCORDANCE WITH RCSC
"SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR ASTM A490 BOLTS."
3. WELDED CONSTRUCTION SHALL COMPLY WITH AWS D1.1 FOR PROCEDURES,
APPEARANCE, QUALITY OF WELD, AND METHODS USED IN CORRECTING WELDED WORK.
4. THE FABRICATOR SHALL FURNISH AND INSTALL ERECTION CLIPS FOR FIT-UP OF WELDED
CONNECTIONS.
5. DOUBLE ANGLE MEMBERS SHALL HAVE WELDED FILLERS SPACED IN ACCORDANCE WITH
CHAPTER E4 OF THE AISC-ASD SPECIFICATION.
6. GUSSET AND STIFFENER PLATES SHALL BE 3/8 INCH THICK MINIMUM.
3.2 PRIMING:
A. STRUCTURAL STEEL SHALL BE PRIMED AS SPECIFIED HEREIN, UNLESS SHOWN
OTHERWISE ON THE DRAWINGS.
B. STRUCTURAL STEEL SURFACE PREPARATION SHALL CONFORM TO SSPC-SP3, "POWER
TOOL CLEANING."
C. SURFACE PREPARATION AND PRIMER SHALL BE IN ACCORDANCE WITH AISC CODE OF
STANDARD PRACTICE AS INCLUDED IN THE ASD MANUAL OF STEEL CONSTRUCTION.
D. MATERIALS SHALL REMAIN CLOSED UNTIL REQUIRED FOR USE, MANUFACTURER'S
POT-LIFE REQUIREMENTS SHALL BE STRICTLY ADHERED TO.
E. PRIMER SHALL BE APPLIED TO DRY, CLEAN, PREPARED SURFACE AND UNDER FAVORABLE
CONDITIONS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. UNLESS
OTHERWISE RECOMMENDED BY THE MANUFACTURER PRIMING SHALL NOT BE DONE
WHEN AMBIENT TEMPERATURE IS LESS THAN 50 DEGREE F. THE RELATIVE HUMIDITY IS
MORE THAN 90 PERCENT, OR THE SURFACE TEMPERATURE IS LESS THAN 5 DEGREE F
ABOVE THE DEW POINT.
F. GENERALLY ALL PRIMER SHALL BE SPRAY APPLIED. BRUSH OR ROLLER APPLICATION
SHALL BE RESTRICTED TO TOUCHUP AND TO AREAS NOT ACCESSIBLE BY SPRAY GUN.
G. PRIMER SHALL BE UNIFORMLY APPLIED WITHOUT RUNS, SAGS, SOLVENT BLISTERS, DRY
SPRAY OR OTHER BLEMISHES. ALL BLEMISHES AND OTHER IRREGULARITIES SHALL BE
REPAIRED OR REMOVED AND THE AREA RE-COATED. SPECIAL ATTENTION SHALL BE PAID
TO CREVICES, WELD LINES, BOLT HEADS, CORNERS, EDGES, ETC., TO OBTAIN THE
REQUIRED NOMINAL FILM THICKNESS.
H. THE DRY FILM THICKNESS OF THE PRIMER SHALL BE 2.0 MILS.
I. IF THE PRIMER IS DAMAGED BY WELDING OR PHYSICAL ABUSE, THE AREA SHALL BE
TOUCHED UP AND REPAIRED. THE TOUCHUP PAINT SHALL BE COMPATIBLE WITH THE
APPLIED PRIMER WITH MINIMUM DRY FILM THICKNESS OF 1.5 MILS.
3.3 INSTALLATION:
A. INSTALLATION OF STRUCTURAL STEEL SHALL COMPLY WITH AISC "CODE OF STANDARD
PRACTICE."
B. STRUCTURAL FIELD WELDING SHALL BE DONE BY THE ELECTRIC SUBMERGED OR
SHIELDED METAL ARC PROCESS. WELDED CONSTRUCTION SHALL COMPLY WITH AWS D1.1.
C. PROVIDE ANCHOR BOLTS AND OTHER CONNECTORS REQUIRED FOR SECURING
STRUCTURAL STEEL TO ELEVATOR SHAFT WALLS AND OTHER IN-PLACE WORK. PROVIDE
TEMPLATES AND OTHER DEVICES NECESSARY FOR PRESETTING BOLTS AND ANCHORS TO
ACCURATE LOCATIONS.
D. SPLICE MEMBERS ONLY WHERE INDICATED ON THE DRAWINGS.
E. ANY GAS CUTTING TORCHES HAVE TO BE APPROVED IN WRITING BY THE PROJECT
STRUCTURAL ENGINEER.
F. PROVIDE TEMPORARY SHORING BRACING WITH CONNECTIONS OF SUFFICIENT STRENGTH
TO BEAR IMPOSED LOADS. REMOVE TEMPORARY CONNECTIONS AND MEMBERS WHEN
PERMANENT MEMBERS ARE IN PLACE AND THE FINAL CONNECTIONS HAVE BEEN MADE.
G. ALIGN AND ADJUST MEMBERS, AND OTHER SURFACES WHICH WILL BE IN THE PERMANENT
CONTACT, BEFORE ASSEMBLY.
H. HIGH-STRENGTH BOLTS AS A MINIMUM, SHALL BE TIGHTENED TO A "SNUG TIGHT"
CONDITION AS DEFINED IN THE LATEST AISC SPECIFICATION. ALL HIGH-STRENGTH BOLTS
SPECIFIED ON THE DESIGN DRAWINGS TO BE USED IN PRETENSIONED OR SLIP-CRITICAL
JOINTS SHALL BE TIGHTENED TO A BOLT TENSION NOT LESS THAN THAT GIVEN IN AISC
TABLE J3.1. INSTALLATION SHALL BE BY ANY OF THE FOLLOWING METHODS: TURN-OF NUT
METHOD, A DIRECT-TENSION-INDICATOR, TWIST-OFF-TYPE TENSION-CONTROL BOLT,
CALIBRATED WRENCH, OR ALTERNATIVE DESIGN BOLT.
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
GN4
GENERAL NOTES
(SHEET 4 OF 4)
PRELIMINARY -
NOT FOR
CONSTRUCTION
C. ACHIEVE FINISHED GRADE BY PLACING A MINIMUM OF 4 INCHES OF 1/2" - 3/4" CRUSHED
STONE ON TOP SOIL STABILIZER FABRIC.
D. REPAIR ALL ACCESS ROADS AND SURROUNDING AREAS USED DURING THE COURSE OF
THIS WORK TO THEIR ORIGINAL CONDITION.
3.7 ASPHALT PAVING ROAD:
COLORADO
A. DIVISION 400 - CDOT PAVEMENT
OTHER STATES
A. DOT APPROVED PAVEMENT
GENERAL CONCRETE WORK NOTES:
PART 1 - GENERAL
1.1 SCOPE:
A. FORM WORK, REINFORCING STEEL, ACCESSORIES, CAST-IN PLACE CONCRETE, FINISHING,
CURING AND TESTING FOR STRUCTURAL CONCRETE FOUNDATIONS.
1.2 REFERENCES:
A. ACI (AMERICAN CONCRETE INSTITUTE)
1. ACI 301 SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS.
2. ACI 304 RECOMMENDED PRACTICE FOR MEASURING, MIXING, TRANSPORTING AND
PLACING CONCRETE.
3. ACI 305 RECOMMENDED PRACTICE FOR HOT WEATHER CONCRETING.
4. ACI 306 RECOMMENDED PRACTICE FOR COLD WEATHER CONCRETING.
5. ACI 308 STANDARD PRACTICE FOR CURING CONCRETING.
6. ACI 309 STANDARD PRACTICE FOR CONSOLIDATION OF CONCRETE.
7. ACI 318 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE.
8. ACI 347 RECOMMENDED PRACTICE FOR CONCRETE FORMWORK.
B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS). THE APPLICABLE STANDARDS
OF THE AMERICAN SOCIETY FOR TESTING AND MATERIALS ARE LISTED IN THE ACI
STANDARDS AND ARE A PART OF THIS SPECIFICATION.
PART 2 - PRODUCTS
2.1 REINFORCING MATERIALS:
A. REINFORCING BARS: ASTM A615, GRADE 60, PROPOSED DEFORMED BILLET-STEEL BARS,
PLAIN FINISH.
B. FURNISH CHAIRS, BOLSTERS, BAR SUPPORTS, SPACERS AS REQUIRED FOR SUPPORT OF
REINFORCING STEEL AND WIRE FABRIC.
2.2 CONCRETE MATERIALS:
A. PORTLAND CEMENT SHALL BE TYPE II, CONFORMING TO ASTM C-150.
B. AGGREGATE SHALL CONFORM TO ASTM C-33.
1. FINE AGGREGATE SHALL BE UNIFORMLY GRADED, CLEAN SHARP, WASHED NATURAL, OR
CRUSHED SAND, FREE FROM ORGANIC IMPURITIES.
2. COARSE AGGREGATE SHALL BE NATURAL WASHED GRAVEL OR WASHED CRUSHED ROCK
HAVING HARD, STRONG, DURABLE PIECES, FREE FROM ADHERENT COATINGS.
3. MAXIMUM SIZE OF COARSE AGGREGATE SHALL BE 3/4 INCH IN ACCORDANCE WITH THE
REQUIREMENTS OF ASTM C-33 GRADATION SIZE NO. 67.
C. WATER USED IN CONCRETE MIX SHALL BE POTABLE, CLEAN, AND FREE FROM OILS, ACIDS,
SALTS, CHLORIDES, ALKALI, SUGAR, VEGETABLE, OR OTHER INJURIOUS SUBSTANCES.
D. THE CONCRETE SHALL CONTAIN AN AIR-ENTRAINING ADMIXTURE COMPLYING WITH THE
REQUIREMENTS OF ASTM C-260 AND ACI 212. 1R AND A WATER- REDUCING ADMIXTURE
COMPLYING WITH THE REQUIREMENTS OF ASTM C-494 AND ACI 212. 1R. ADMIXTURES
SHALL BE PURCHASED AND BATCHED IN LIQUID SOLUTION. THE USE OF CALCIUM
CHLORIDE OR AN ADMIXTURE CONTAINING CALCIUM CHLORIDE IS PROHIBITED.
ADMIXTURES SHALL BE OF THE SAME MANUFACTURER TO ASSURE COMPATIBILITY.
ACCEPTABLE MANUFACTURERS ARE:
1. W.R. GRACE
2. SIKA CORP.
3. MASTER BUILDERS
4. EUCLID CHEMICAL CO.
E. CURING COMPOUND SHALL CONFORM TO ASTM C309, TYPE I, ID, CLASS A AND B AND ASTM
C171 AS APPLICABLE.
2.3 CONCRETE MIX:
A. PROPORTION CONCRETE MIX IN ACCORDANCE WITH REQUIREMENTS OF ACI 301. THE
STRENGTH OF CONCRETE SHALL BE AS INDICATED ON THE DRAWINGS. WHERE STRENGTH
IS NOT CLEARLY INDICATED, CONCRETE OF MINIMUM 28 DAY COMPRESSIVE STRENGTH OF
4000 P.S.I. SHALL BE USED.
B. THE CONCRETE MIX SHALL BE DESIGNED FOR A MAXIMUM SLUMP OF THREE INCHES AT
THE POINT OF DISCHARGE. MIXES OF THE STIFFEST CONSISTENCY THAT CAN BE
EFFICIENTLY PLACED SHALL BE USED.
C. ALL CONCRETE SHALL HAVE (3) TO FIVE (5) PERCENT ENTRAINED AIR.
D. ALL STRUCTURAL CONCRETE SHALL CONTAIN A WATER-REDUCING AGENT.
PART 3 - EXECUTION
3.1 GENERAL:
A. CONSTRUCT AND ERECT THE FORM WORK IN ACCORDANCE WITH ACI 301 AND ACI 347.
B. COLD-WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 306.
C. HOT-WEATHER CONCRETING SHALL BE IN ACCORDANCE WITH ACI 305.
3.2 INSERTS, EMBEDDED COMPONENTS AND OPENINGS:
A. CONTRACTOR SHALL CHECK ALL CIVIL, ARCHITECTURAL, STRUCTURAL AND ELECTRICAL
DRAWINGS FOR OPENINGS, SLEEVES, ANCHOR BOLTS, INSERTS AND OTHER ITEMS TO BE
BUILT INTO THE CONCRETE WORK.
B. COORDINATE THE WORK OF OTHER SECTION IN FORMING AND SETTING OPENINGS.
RECESSES, SLOTS, CHASES, ANCHORS, INSERTS AND OTHER ITEMS TO BE EMBEDDED.
C. EMBEDDED ITEMS SHALL BE SET ACCURATELY IN LOCATION, ALIGNMENT, ELEVATION AND
PLUMBNESS, LOCATE AND MEASURE FROM ESTABLISHED SURVEYED REFERENCE
BENCHMARKS.
D. EMBEDDED ITEMS SHALL BE ANCHORED INTO PLACE IN A MANNER TO PREVENT
MOVEMENT DURING CONCRETE PLACEMENT AND CONSOLIDATION. COMPONENTS
FORMING A PART OF A COMPLETE ASSEMBLY SHALL BE ALIGNED BEFORE ANCHORING
INTO PLACE. PROVIDE TEMPORARY BRACING, ANCHORAGE, AND TEMPLATES AS REQUIRED
TO MAINTAIN THE SETTING AND ALIGNMENT.
3.3 REINFORCEMENT PLACEMENT:
A. PLACE REINFORCEMENT ACCORDING TO CHECKED AND RELEASED DRAWINGS AND IN
ACCORDANCE WITH ACI 301 AND ACI 318.
B. ACCURATELY POSITION, SUPPORT AND SECURE REINFORCEMENT AGAINST
DISPLACEMENT FROM FORM WORK CONSTRUCTION OR CONCRETE PLACEMENT AND
CONSOLIDATION. SUPPORT REINFORCING ON METAL CHAIRS, RUNNERS, BOLSTERS,
SPACERS AND HANGERS.
C. SPLICES OF REINFORCING BARS SHALL BE CLASS B UNLESS SHOWN OTHERWISE ON THE
DRAWINGS. SPLICES SHALL BE STAGGERED. FULL DEVELOPMENT LENGTH SHALL BE
PROVIDED ACROSS JOINTS.
D. LOCATE REINFORCING TO PROVIDE CONCRETE COVER AND SPACING SHOWN ON THE
DRAWINGS. MINIMUM COVER SHALL BE AS REQUIRED BY ACI 318.
E. WELDING OF AND TO ANY REINFORCING MATERIALS INCLUDING TACK WELDING OF
CROSSING BARS IS STRICTLY PROHIBITED.
3.4 CONCRETE PLACEMENT:
A. PRIOR TO PLACING CONCRETE, THE FORMS AND REINFORCEMENT SHALL BE
THOROUGHLY INSPECTED; ALL TEMPORARY BRACING, TIES AND CLEATS REMOVED; ALL
OPENINGS FOR UTILITIES PROPERLY BOXED; ALL FORMS PROPERLY SECURED IN THERE
CORRECT POSITION AND MADE TIGHT. ALL REINFORCEMENT AND EMBEDDED ITEMS SHALL
BE SECURED IN THEIR PROPER LOCATIONS. ALL OLD AND DRY CONCRETE AND DIRT SHALL
BE CLEANED OFF AND ALL STANDING WATER AND OTHER FOREIGN MATERIAL REMOVED.
B. PLACING CONCRETE SHALL BE IN ACCORDANCE WITH ACI 301 AND ACI 304 AND SHALL BE
CARRIED OUT AT SUCH A RATE THAT THE CONCRETE PREVIOUSLY PLACED IS STILL
PLASTIC AND INTEGRATED WITH THE FRESHLY PLACED CONCRETE. CONCRETING ONCE
STARTED, SHALL BE CARRIED ON AS A CONTINUOUS OPERATION UNTIL THE SECTION IS
COMPLETED. NO COLD JOINTS SHALL BE ALLOWED.
C. ALL CONCRETE SHALL BE THOROUGHLY CONSOLIDATED AND COMPACTED BY VIBRATION
SPACING, RODDING, OR FORKING DURING THE OPERATION OF PLACING AND DEPOSITING
IN ACCORDANCE WITH ACI 309. THE CONCRETE SHALL BE THOROUGHLY WORKED AROUND
REINFORCEMENT, EMBEDDED ITEMS, AND INTO THE CORNER OF THE FORMS SO AS TO
ELIMINATE ALL AIR AND STONE POCKETS.
3.5 FINISHING:
A. FINISHING OF THE FLOOR SLABS SHALL BE IN ACCORDANCE WITH ACI 302.1 SECTION 7.2
WITH A MINIMUM OF THREE TROWELINGS. THE SLAB FINISH TOLERANCE AS MEASURED IN
ACCORDANCE WITH ASTM E 1155 SHALL HAVE AN OVERALL TEST NUMBER FOR FLATNESS,
FF= 20 AND FOR LEVEL. FL=15. THE MINIMUM LOCAL NUMBER FOR FLATNESS, FF= 15 AND
FOR LEVEL FL=10.
B. SURFACE OF FLOOR SLAB SHALL RECEIVE TWO COATS OF CLEAR SEALER/HARDNER.
C. ABOVE GRADE WALL SURFACES SHALL HAVE A SMOOTH FORM FINISH AS DEFINED IN
CHAPTER 10 OF ACI 301.
PRELIMINARY -
NOT FOR
CONSTRUCTION
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
GN3
GENERAL NOTES
(SHEET 3 OF 4)
C. OSHA (OCCUPATION SAFETY AND HEALTH ADMINISTRATION).
1.2 INSPECTION AND TESTING:
A. FIELD TESTING OF EARTHWORK COMPACTION AND CONCRETE CYLINDERS SHALL BE
PERFORMED BY SUBCONTRACTORS INDEPENDENT TESTING LAB. THIS WORK TO BE
COORDINATED BY THE SUBCONTRACTOR.
B. ALL WORK SHALL BE INSPECTED AND RELEASED BY THE GENERAL CONTRACTOR WHO
SHALL CARRY OUT THE GENERAL INSPECTION OF THE WORK WITH SPECIFIC CONCERN TO
PROPER PERFORMANCE OF THE WORK AS SPECIFIED AND/OR CALLED FOR ON THE
DRAWINGS. IT IS THE SUBCONTRACTOR'S RESPONSIBILITY TO REQUEST TIMELY
INSPECTIONS PRIOR TO PROCEEDING WITH FURTHER WORK THAT WOULD MAKE PARTS OF
WORK INACCESSIBLE OR DIFFICULT TO INSPECT.
1.3 SITE MAINTENANCE AND PROTECTION:
A. PROVIDE ALL NECESSARY JOB SITE MAINTENANCE FROM COMMENCEMENT OF WORK UNTIL
COMPLETION OF THE SUBCONTRACT.
B. AVOID DAMAGE TO THE SITE AND TO EXISTING FACILITIES, STRUCTURES, TREES, AND
SHRUBS DESIGNATED TO REMAIN. TAKE PROTECTIVE MEASURES TO PREVENT EXISTING
FACILITIES THAT ARE NOT DESIGNATED FOR REMOVAL FROM BEING DAMAGED BY THE
WORK.
C. KEEP SITE FREE OF ALL PONDING WATER.
D. PROVIDE EROSION CONTROL MEASURES IN ACCORDANCE WITH STATE DOT AND EPA
REQUIREMENTS.
E. PROVIDE AND MAINTAIN ALL TEMPORARY FENCING, BARRICADES, WARNING SIGNALS AND
SIMILAR DEVICES NECESSARY TO PROTECT AGAINST THEFT FROM PROPERTY DURING THE
ENTIRE PERIOD OF CONSTRUCTION. REMOVE ALL SUCH DEVICES UPON COMPLETION OF
THE WORK.
F. EXISTING UTILITIES: DO NOT INTERRUPT EXISTING UTILITIES SERVING FACILITIES OCCUPIED
BY THE OWNER OR OTHERS, EXCEPT WHEN PERMITTED IN WRITING BY THE ENGINEER AND
THEN ONLY AFTER ACCEPTABLE TEMPORARY UTILITY SERVICES HAVE BEEN PROVIDED.
1. PROVIDE A MINIMUM 48-HOUR NOTICE TO THE ENGINEER AND RECEIVE WRITTEN NOTICE TO
PROCEED BEFORE INTERRUPTING ANY UTILITY SERVICE.
PART 2 - PRODUCTS
2.1 SUITABLE BACKFILL: ASTM D2321 (CLASS I, II, III OR IVA) FREE FROM FROZEN LUMPS, REFUSE,
STONES OR ROCKS LARGER THAN 3 INCHES IN ANY DIMENSION OR OTHER MATERIAL THAT
MAY MAKE THE INORGANIC MATERIAL UNSUITABLE FOR BACKFILL.
2.2 NON-POROUS GRANULAR EMBANKMENT AND BACKFILL: ASTM D2321 (CLASS III, IVA OR IVB)
COARSE AGGREGATE. FREE FROM FROZEN LUMPS, REFUSE, STONES OR ROCKS LARGER
THAN 3 INCHES IN ANY DIMENSION OR OTHER MATERIAL THAT MAY MAKE THE INORGANIC
MATERIAL UNSUITABLE FOR BACKFILL.
2.3 POROUS GRANULAR EMBANKMENT AND BACKFILL: ASTM D2321 (CLASS IA, IB OR II) COARSE
AGGREGATE FREE FROM FROZEN LUMPS, REFUSE, STONES OR ROCKS LARGER THAN 3
INCHES IN ANY DIMENSION OR OTHER MATERIAL THAT MAY MAKE THE INORGANIC MATERIAL
UNSUITABLE FOR BACKFILL.
2.4 SELECT STRUCTURAL FILL: GRANULAR FILL MATERIAL MEETING THE REQUIREMENTS OF
ASTM E850-95. FOR USE AROUND AND UNDER STRUCTURES WHERE STRUCTURAL FILL
MATERIAL ARE REQUIRED.
2.5 GRANULAR BEDDING AND TRENCH BACKFILL: WELL-GRADED SAND MEETING THE GRADATION
REQUIREMENTS OF ASTM D2487 (SE OR SW-SM).
2.6 COARSE AGGREGATE FOR ACCESS ROAD SUB-BASE COURSE SHALL CONFORM TO ASTM
D2940.
2.7 UNSUITABLE MATERIAL: HIGH AND MODERATELY PLASTIC SILTS AND CLAYS (LL>45). MATERIAL
CONTAINING REFUSE, FROZEN LUMPS, DEMOLISHED BITUMINOUS MATERIAL, VEGETATIVE
MATTER, WOOD, STONES IN EXCESS OF 3 INCHES IN ANY DIMENSION, AND DEBRIS AS
DETERMINED BY THE CONSTRUCTION MANAGER. TYPICAL THESE WILL BE SOILS CLASSIFIED
BY ASTM AS PT, MH, CH, OH, ML, AND OL.
2.8 GEOTEXTILE FABRIC: MIRAFI 500X OR ENGINEERED APPROVED EQUAL.
2.9 PLASTIC MARKING TAPE: SHALL BE ACID AND ALKALI RESISTANT POLYETHYLENE FILM
SPECIFICALLY MANUFACTURED FOR MARKING AND LOCATING UNDERGROUND UTILITIES, 6
INCHES WIDE WITH A MINIMUM THICKNESS OF 0.004 INCH. TAPE SHALL HAVE MINIMUM
STRENGTH OF 1500 PSI IN BOTH DIRECTIONS AND MANUFACTURED WITH INTEGRAL
CONDUCTORS, FOIL BACKING OR OTHER MEANS TO ENABLE DETECTION BY A METAL
DETECTOR WHEN BURIED UP TO 3 FEET DEEP. THE METALLIC CORE OF THE TAPE SHALL BE
ENCASED IN A PROTECTIVE JACKET OR PROVIDED WITH OTHER MEANS TO PROTECT IT FROM
CORROSION. TAPE COLOR SHALL BE RED FOR ELECTRIC UTILITIES AND ORANGE FOR
TELECOMMUNICATION UTILITIES.
PART 3 - EXECUTION
3.1 GENERAL:
A. BEFORE STARTING GENERAL SITE PREPARATION ACTIVITIES, INSTALL EROSION AND
SEDIMENT CONTROL MEASURES. THE WORK AREA SHALL BE CONSTRUCTED AND
MAINTAINED IN SUCH CONDITION THAT IN THE EVENT OF RAIN THE SITE WILL BE DRAINED AT
ANY TIME.
B. BEFORE ALL SURVEY, LAYOUT, STAKING, AND MARKING, ESTABLISH AND MAINTAIN ALL
LINES, GRADES, ELEVATIONS AND BENCHMARKS NEEDED FOR EXECUTION OF THE WORK.
C. CLEAR AND GRUB THE AREA WITHIN THE LIMITS OF THE SITE. REMOVE TREES, BRUSH,
STUMPS, RUBBISH AND OTHER DEBRIS AND VEGETATION RESTING ON OR PROTRUDING
THROUGH THE SURFACE OF THE SITE AREA TO BE CLEARED.
1. REMOVE THE FOLLOWING MATERIALS TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE
ORIGINAL GROUND SURFACE: ROOTS, STUMPS, AND OTHER DEBRIS, BRUSH, AND REFUSE
EMBEDDED IN OR PROTRUDING THROUGH THE GROUND SURFACE, RAKE, DISK OR PLOW THE
AREA TO A DEPTH OF NO LESS THAN 6 INCHES, AND REMOVE TO A DEPTH OF 12 INCHES ALL
ROOTS AND OTHER DEBRIS THEREBY EXPOSED.
2. REMOVE TOPSOIL MATERIAL COMPLETELY FROM THE SURFACE UNTIL THE SOIL NO LONGER
MEETS THE DEFINITION OF TOPSOIL. AVOID MIXING TOPSOIL WITH SUBSOIL OR OTHER
UNDESIRABLE MATERIALS.
3. EXCEPT WHERE EXCAVATION TO GREATER DEPTH IS INDICATED, FILL DEPRESSIONS
RESULTING FROM CLEARING, GRUBBING AND DEMOLITION WORK COMPLETELY WITH SUITABLE
FILL.
A. REMOVE FROM THE SITE AND DISPOSE IN AN AUTHORIZED LANDFILL ALL DEBRIS RESULTING
FROM CLEARING AND GRUBBING OPERATIONS. BURNING WILL NOT BE PERMITTED.
B. PRIOR TO EXCAVATING, THOROUGHLY EXAMINE THE AREA TO BE EXCAVATED AND/OR
TRENCHED TO VERIFY THE LOCATIONS OF FEATURES INDICATED ON THE DRAWINGS AND TO
ASCERTAIN THE EXISTENCE AND LOCATION OF ANY STRUCTURE, UNDERGROUND
STRUCTURE, OR OTHER ITEM NOT SHOWN THAT MIGHT INTERFERE WITH THE PROPOSED
CONSTRUCTION. NOTIFY THE CONSTRUCTION MANAGER OF ANY OBSTRUCTIONS THAT WILL
PREVENT ACCOMPLISHMENT OF THE WORK AS INDICATED ON THE DRAWINGS.
C. SEPARATE AND STOCK PILE ALL EXCAVATED MATERIALS SUITABLE FOR BACKFILL. ALL
EXCESS EXCAVATED AND UNSUITABLE MATERIALS SHALL BE DISPOSED OF OFF-SITE IN A
LEGAL MANNER.
3.2 BACKFILL:
A. AS SOON AS PRACTICAL, AFTER COMPLETING CONSTRUCTION OF THE RELATED
STRUCTURE, INCLUDING EXPIRATION OF THE SPECIFIED MINIMUM CURING PERIOD FOR
CAST-IN-PLACE CONCRETE, BACKFILL THE EXCAVATION WITH APPROVED MATERIAL TO
RESTORE THE REQUIRED FINISHED GRADE.
1. PRIOR TO PLACING BACKFILL AROUND STRUCTURES, ALL FORMS SHALL BE REMOVED AND THE
EXCAVATION CLEANED OF ALL TRASH, DEBRIS, AND UNSUITABLE MATERIALS.
2. BACKFILL BY PLACING AND COMPACTING SUITABLE BACKFILL MATERIAL OR SELECT GRANULAR
BACKFILL MATERIAL WHEN REQUIRED IN UNIFORM HORIZONTAL LAYERS OF NO GREATER THAN
8-INCHES LOOSE THICKNESS AND COMPACTED. WHERE HAND OPERATED COMPACTORS ARE
USED, THE FILL MATERIAL SHALL BE PLACED IN LIFTS NOT TO EXCEED 4 INCHES IN LOOSE
DEPTH AND COMPACTED.
3. WHENEVER THE DENSITY TESTING INDICATES THAT THE CONTRACTOR HAS NOT OBTAINED
THE SPECIFIED DENSITY, THE SUCCEEDING LAYER SHALL NOT BE PLACED UNTIL THE
SPECIFICATION REQUIREMENTS ARE MET UNLESS OTHERWISE AUTHORIZED BY THE
GEOTECHNICAL ENGINEER. THE CONTRACTOR SHALL TAKE WHATEVER APPROPRIATE ACTION
IS NECESSARY, SUCH AS DISKING AND DRYING, ADDING WATER, OR INCREASING THE
COMPACTIVE EFFORT TO MEET THE MINIMUM COMPACTION REQUIREMENTS.
B. THOROUGHLY COMPACT EACH LAYER OF BACKFILL TO A MINIMUM OF 95 PERCENT OF THE
MAXIMUM DRY DENSITY AS PROVIDED BY THE STANDARD PROCTOR TEST, ASTM D 698.
3.3 TRENCH EXCAVATION:
A. UTILITY TRENCHES SHALL BE EXCAVATED TO THE LINES AND GRADES SHOWN ON THE
DRAWINGS OR AS DIRECTED BY THE GENERAL CONTRACTOR. PROVIDE SHORING, SHEETING
AND BRACING AS REQUIRED TO PREVENT CAVING OR SLOUGHING OF THE TRENCH WALLS.
B. EXTEND THE TRENCH WIDTH A MINIMUM OF 6 INCHES BEYOND THE OUTSIDE EDGE OF THE
OUTERMOST CONDUIT.
C. WHEN SOFT YIELDING, OR OTHERWISE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED,
BACKFILL AT THE REQUIRED TRENCH TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE
REQUIRED ELEVATION AND BACKFILL WITH GRANULAR BEDDING MATERIAL.
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
GN2
GENERAL NOTES
(SHEET 2 OF 4)
PRELIMINARY -
NOT FOR
CONSTRUCTION
10. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF WORK AREA,
ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED BY THE
WORK UNDER THIS CONTRACT. WORK SHALL CONFIRM TO ALL OSHA REQUIREMENTS AND THE
LOCAL JURISDICTION.
11. GENERAL CONTRACTOR SHALL COORDINATE WORK AND SCHEDULE WORK ACTIVITIES WITH
OTHER DISCIPLINES.
12. ERECTION SHALL BE DONE IN A WORKMANLIKE MANNER BY COMPETENT EXPERIENCED
WORKMAN IN ACCORDANCE WITH APPLICABLE CODES AND THE BEST ACCEPTED PRACTICE.
ALL MEMBERS SHALL BE LAID PLUMB AND TRUE AS INDICATED ON THE DRAWINGS.
13. SEAL PENETRATIONS THROUGH FIRE RATED AREAS WITH UL LISTED MATERIALS APPROVED
BY LOCAL JURISDICTION. CONTRACTOR SHALL KEEP AREA CLEAN, HAZARD FREE, AND
DISPOSE OF ALL DEBRIS.
14. WORK PREVIOUSLY COMPLETED IS REPRESENTED BY LIGHT SHADED LINES AND NOTES. THE
SCOPE OF WORK FOR THIS PROJECT IS REPRESENTED BY DARK SHADED LINES AND NOTES.
CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR OF ANY EXISTING CONDITIONS
THAT DEVIATE FROM THE DRAWINGS PRIOR TO BEGINNING CONSTRUCTION.
15. CONTRACTOR SHALL PROVIDE WRITTEN NOTICE TO THE CONSTRUCTION MANAGER 48 HOURS
PRIOR TO COMMENCEMENT OF WORK.
16. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS,
LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT
CONTRACTOR'S EXPENSE TO THE SATISFACTION OF THE OWNER.
17. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF
CONSTRUCTION.
18. GENERAL CONTRACTOR SHALL COORDINATE AND MAINTAIN ACCESS FOR ALL TRADES AND
CONTRACTORS TO THE SITE AND/OR BUILDING.
19. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURITY OF THE SITE FOR THE
DURATION OF CONSTRUCTION UNTIL JOB COMPLETION.
20. THE GENERAL CONTRACTOR SHALL MAINTAIN IN GOOD CONDITION ONE COMPLETE SET OF
PLANS WITH ALL REVISIONS, ADDENDA, AND CHANGE ORDERS ON THE PREMISES AT ALL
TIMES.
21. THE GENERAL CONTRACTOR SHALL PROVIDE PORTABLE FIRE EXTINGUISHERS WITH A RATING
OF NOT LESS THAN 2-A OT 2-A:10-B:C AND SHALL BE WITHIN 25 FEET OF TRAVEL DISTANCE TO
ALL PORTIONS OF WHERE THE WORK IS BEING COMPLETED DURING CONSTRUCTION.
22. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES SHALL BE
PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE
WORK, SHALL BE RELOCATED AS DIRECTED BY THE ENGINEER AND RF. EXTREME CAUTION
SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR
NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW.
THIS SHALL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION, B) CONFINED SPACE, C)
ELECTRICAL SAFETY, AND D) TRENCHING & EXCAVATION.
23. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES, WHICH
INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED, CAPPED, PLUGGED OR
OTHERWISE DISCONNECTED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION
OF THE WORK, AS DIRECTED BY THE RESPONSIBLE ENGINEER, AND SUBJECT TO THE
APPROVAL OF THE OWNER AND/OR LOCAL UTILITIES.
24. THE AREAS OF THE OWNER'S PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY
THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND
STABILIZED TO PREVENT EROSION.
25. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION.
EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN
CONFORMANCE WITH THE FEDERAL AND LOCAL JURISDICTION FOR EROSION AND SEDIMENT
CONTROL.
26. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUNDING. FROZEN
MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT.
27. THE SUBGRADE SHALL BE BROUGHT TO A SMOOTH UNIFORM GRADE AND COMPACTED TO 95
PERCENT STANDARD PROCTOR DENSITY UNDER PAVEMENT AND STRUCTURES AND 80
PERCENT STANDARD PROCTOR DENSITY IN OPEN SPACE. ALL TRENCHES IN PUBLIC RIGHT OF
WAY SHALL BE BACKFILLED WITH FLOWABLE FILL OR OTHER MATERIAL PRE-APPROVED BY
THE LOCAL JURISDICTION.
28. ALL NECESSARY RUBBISH, STUMPS, DEBRIS, STICKS, STONES, AND OTHER REFUSE SHALL BE
REMOVED FROM THE SITE AND DISPOSED OF IN A LAWFUL MANNER.
29. ALL BROCHURES, OPERATING AND MAINTENANCE MANUALS, CATALOGS, SHOP DRAWINGS,
AND OTHER DOCUMENTS SHALL BE TURNED OVER TO THE GENERAL CONTRACTOR AT
COMPLETION OF CONSTRUCTION AND PRIOR TO PAYMENT.
30. CONTRACTOR SHALL SUBMIT A COMPLETE SET OF AS-BUILT REDLINES TO THE GENERAL
CONTRACTOR UPON COMPLETION OF PROJECT AND PRIOR TO FINAL PAYMENT.
31. CONTRACTOR SHALL LEAVE PREMISES IN A CLEAN CONDITION.
32. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR
SEWER SERVICE, AND IS NOT FOR HUMAN HABITAT (NO HANDICAP ACCESS REQUIRED).
33. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2
TIMES PER MONTH, BY VERIZON WIRELESS TECHNICIANS.
34. NO OUTDOOR STORAGE OR SOLID WASTE CONTAINERS ARE PROPOSED.
35. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH
THE LATEST REVISION VERIZON WIRELESS MOBILITY GROUNDING STANDARD "TECHNICAL
SPECIFICATION FOR CONSTRUCTION OF GSM/GPRS WIRELESS SITES" AND "TECHNICAL
SPECIFICATION FOR FACILITY GROUNDING". IN CASE OF A CONFLICT BETWEEN THE
CONSTRUCTION SPECIFICATION AND THE DRAWINGS, THE DRAWINGS SHALL GOVERN.
36. CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS
REQUIRED FOR CONSTRUCTION. IF CONTRACTOR CANNOT OBTAIN A PERMIT, THEY MUST
NOTIFY THE GENERAL CONTRACTOR IMMEDIATELY.
37. CONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS.
38. INFORMATION SHOWN ON THESE DRAWINGS WAS OBTAINED FROM SITE VISITS AND/OR
DRAWINGS PROVIDED BY THE SITE OWNER. CONTRACTORS SHALL NOTIFY THE ENGINEER OF
ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION.
39. NO WHITE STROBE LIGHTS ARE PERMITTED. LIGHTING IF REQUIRED, WILL MEET FAA
STANDARDS AND REQUIREMENTS.
40. ALL COAXIAL CABLE INSTALLATIONS TO FOLLOW MANUFACTURER'S INSTRUCTIONS AND
RECOMMENDATIONS.
ANTENNA MOUNTING
41. DESIGN AND CONSTRUCTION OF ANTENNA SUPPORTS SHALL CONFORM TO CURRENT
ANSI/TIA-222 OR APPLICABLE LOCAL CODES.
42. ALL STEEL MATERIALS SHALL BE GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH
ASTM A123 "ZINC (HOT-DIP GALVANIZED) COATINGS ON IRON AND STEEL PRODUCTS", UNLESS
NOTED OTHERWISE.
43. ALL BOLTS, ANCHORS AND MISCELLANEOUS HARDWARE SHALL BE GALVANIZED IN
ACCORDANCE WITH ASTM A153 "ZINC-COATING (HOT-DIP) ON IRON AND STEEL HARDWARE",
UNLESS NOTED OTHERWISE.
44. DAMAGED GALVANIZED SURFACES SHALL BE REPAIRED BY COLD GALVANIZING IN
ACCORDANCE WITH ASTM A780.
45. ALL ANTENNA MOUNTS SHALL BE INSTALLED WITH LOCK NUTS, DOUBLE NUTS AND SHALL BE
TORQUED TO MANUFACTURER'S RECOMMENDATIONS.
46. CONTRACTOR SHALL INSTALL ANTENNA PER MANUFACTURER'S RECOMMENDATION FOR
INSTALLATION AND GROUNDING.
47. ALL UNUSED PORTS ON ANY ANTENNA SHALL BE COVERED WITH CONCEALER CAP WITH
PROPER WEATHER PROOFING OR BE TERMINATED WITH A 50 LOAD.
48. PRIOR TO SETTING ANTENNA AZIMUTHS AND DOWNTILTS, ANTENNA CONTRACTOR SHALL
CHECK THE ANTENNA MOUNT FOR TIGHTNESS AND ENSURE THAT THEY ARE PLUMB.
ANTENNA AZIMUTHS SHALL BE SET FROM TRUE NORTH AND BE ORIENTED WITHIN +/- 5° AS
DEFINED BY THE FINAL RF DESIGN. ANTENNA DOWNTILTS SHALL BE WITHIN +/- 0.5° AS
DEFINED BY THE RFDS.
49. JUMPERS FROM THE TMA'S MUST TERMINATE TO OPPOSITE POLARIZATION'S IN EACH SECTOR,
U.O.N.
50. CONTRACTOR SHALL RECORD THE SERIAL #, SECTOR, AND POSITION OF EACH ACTUATOR
INSTALLED AT THE ANTENNAS AND PROVIDE THE INFORMATION TO VERIZON WIRELESS.
51. TMA'S SHALL BE MOUNTED ON PIPE DIRECTLY BEHIND ANTENNAS AS CLOSE TO ANTENNA AS
FEASIBLE IN A VERTICAL POSITION, U.O.N.
52. ANTENNAS SHALL HAVE SEPARATION PER RF DESIGN, U.O.N.
TORQUE REQUIREMENTS
53. ALL RF CONNECTIONS SHALL BE TIGHTENED BY A TORQUE WRENCH.
54. ALL RF CONNECTIONS, GROUNDING HARDWARE AND ANTENNA HARDWARE SHALL HAVE A
TORQUE MARK INSTALLED IN A CONTINUOUS STRAIGHT LINE FROM BOTH SIDES OF THE
CONNECTION.
A. RF CONNECTION BOTH SIDES OF THE CONNECTOR.
B. GROUNDING AND ANTENNA HARDWARE ON THE NUT SIDE STARTING FROM THE THREADS TO
THE SOLID SURFACE. EXAMPLE OF SOLID SURFACE: GROUND BAR, ANTENNA BRACKET
METAL.
55. ALL 8M ANTENNA HARDWARE SHALL BE TIGHTENED TO 9 LB-FT (12 NM).
56. ALL 12M ANTENNA HARDWARE SHALL BE TIGHTENED TO 43 LB-FT (58 NM).
57. ALL GROUNDING HARDWARE SHALL BE TIGHTENED UNTIL THE LOCK WASHER COLLAPSES AND
THE GROUNDING HARDWARE IS NO LONGER LOOSE.
58. ALL DIN TYPE CONNECTIONS SHALL BE TIGHTENED TO 18-22 LB-FT (24.4 - 29.8 NM).
59. ALL N TYPE CONNECTIONS SHALL BE TIGHTENED TO 15-20 LB-IN (1.7 - 2.3 NM).
FIBER & POWER CABLE MOUNTING
60. THE FIBER OPTIC TRUNK CABLES SHALL BE INSTALLED INTO CONDUITS, CHANNEL CABLE
TRAYS, OR CABLE TRAY. WHEN INSTALLING FIBER OPTIC TRUNK CABLES INTO A CABLE TRAY
SYSTEM, THEY SHALL BE INSTALLED INTO AN INTER DUCT AND A PARTITION BARRIER SHALL BE
INSTALLED BETWEEN THE 600 VOLT CABLES AND THE INTER DUCT IN ORDER TO SEGREGATE
CABLE TYPES. OPTIC FIBER TRUNK CABLES SHALL HAVE APPROVED CABLE RESTRAINTS EVERY
(6) SIX FEET AND SECURELY FASTENED TO THE CABLE TRAY SYSTEM. NFPA 70 (NEC) ARTICLE
770 RULES SHALL APPLY.
61. CABLES SHALL BE INSTALLED INTO CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY AND
SHALL BE SECURED AT INTERVALS NOT EXCEEDING (6) SIX FEET. AN EXCEPTION; WHERE TYPE
TC-ER CABLES ARE NOT SUBJECT TO PHYSICAL DAMAGE, CABLES SHALL BE PERMITTED TO
MAKE A TRANSITION BETWEEN CONDUITS, CHANNEL CABLE TRAYS, OR CABLE TRAY WHICH ARE
SERVING UTILIZATION EQUIPMENT OR DEVICES, A DISTANCE (6) SIX FEET SHALL NOT BE
EXCEEDED WITHOUT CONTINUOUS SUPPORTING. NFPA 70 (NEC) ARTICLES 336 AND 392 RULES
SHALL APPLY.
62. WHEN INSTALLING OPTIC FIBER TRUNK CABLES OR TYPE TC-ER CABLES INTO CONDUITS, NFPA
70 (NEC) ARTICLE 300 RULES SHALL APPLY.
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
GN1
GENERAL NOTES
(SHEET 1 OF 4)
PRELIMINARY -
NOT FOR
CONSTRUCTION
8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the
appropriate utility company for any utility crossings required.
9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the
Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the
Local Entity prior to beginning construction.
10. The Developer shall coordinate and cooperate with the Local Entity, and all utility companies involved, to assure
that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be
responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility
companies.
18. The Local Entity shall not be responsible for any damages or injuries sustained in this Development as a result of
groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such
damage or injuries are sustained as a result of the Local Entity failure to properly maintain its water, wastewater,
and/or storm drainage facilities in the development.
21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public
street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine
broom sweep, light duty front-end loader, etc.) or as approved by the Local Entity street inspector.
30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching,
shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching.
36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not
shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings.
37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the
appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job.
38. If, during the construction process, conditions are encountered which could indicate a situation that is not
identified in the plans or specifications, the Developer shall contact the Designer and the Local Entity Engineer
immediately.
39. Developer shall be responsible for recording as-built information on a set of record drawings kept on the
construction site, and available to the Local Entity's Inspector at all times. Upon completion of the work, the
contractor(s) shall submit record drawings to the Local Entity Engineer.
42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets,
sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to
construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise
indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first
Certificate of Occupancy.
Appendix E-2
A. Standard Grading and Erosion and Sediment Control Construction Plan Notes
1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this
site.
2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans.
4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site
erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer
shall also be responsible for installing and maintaining all erosion control facilities shown herein.
8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up
and removal of all sediment and debris from all drainage infrastructure and other public facilities.
9. The contractor shall clean up any inadvertent deposited material immediately and make sure streets are free of
all materials by the end of each working day.
14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so
as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon
completion of construction activities the concrete washout material will be removed and properly disposed of prior to
the area being restored.
All changes, addendums, additions, deletions and
modifications to these drawings must be approved,
in writing, by the Fort Collins-Loveland
Water District and the South Fort Collins Sanitation District.
Mr. Terry Farrill, P.E., District Engineer Date
FORT COLLINS - LOVELAND
WATER DISTRICT
SOUTH FORT COLLINS
SANITATION DISTRICT
TYP. (SEE LS1)
EX. PARKING
LOT
NEW VZW CAGED ACCESS LADDER
WITH HINGED LOCKING SECURITY
GUARD, TO LOWER LEVEL ROOF
NEW VZW ANTENNAS MOUNTED ON
STEEL PLATFORM AND CONCEALED
INSIDE RF TRANSPARENT SCREEN
WALLS PAINTED TO MATCH
EXISTING BUILDING, (SEE 3/Z2)
NEW VZW 15' ACCESS
EASEMENT TO R.O.W.
NEW VZW 5' UTILITY
EASEMENT
NEW VZW ACCESS
LADDER W/ SECURITY
PANEL AND LOCK, TO
UPPER LEVEL ROOF
NEW VZW FIBER H.H.
NEAR PROPERTY LINE,
(EXACT LOCATION T.B.D.)
15'-0"
EX. WATER / WASTEWATER PIPE CROSSING COORDINATION:
CONTACT: DAN MOGEN WATER / WASTEWATER & STORMWATER
ENGINEERING, CITY OF FT. COLLINS 970-224-6192 DMOGEN@FCGOV.COM
1. CONTRACTOR TO HAVE POSITVE IDENTIFICATION OF ALL EXISTING
UNDERGROUND SERVICES IN THE PROPOSED WORK AREA PRIOR TO
BEGINNING ANY WORK.
Transmitting Antenna(s)
Radio frequency fields beyond this point MAY
EXCEED the FCC General Population exposure
limit.
Obey all posted signs and site guidelines.
Call Verizon Wireless at 1-800-264-6620 PRIOR
to working beyond this point.
State: ____ SWITCH: ______________
SITE ID: ________________________
SECTOR/NODE: ___________________
NOTICE
verizon
Transmitting Antenna(s)
Radio frequency fields beyond this point MAY
EXCEED the FCC Occupational exposure limit.
Obey all posted signs and site guidelines.
Call Verizon Wireless at 1-800-264-6620 PRIOR
to working beyond this point.
State: ____ SWITCH: ______________
SITE ID: ________________________
SECTOR/NODE: ___________________
CAUTION
verizon
Transmitting Antenna(s)
Radio frequency fields beyond this point
EXCEED the FCC Occupational exposure limit.
Obey all posted signs and site guidelines.
Call Verizon Wireless at 1-800-264-6620 PRIOR
to working beyond this point.
State: ____ SWITCH: ______________
SITE ID: ________________________
SECTOR/NODE: ___________________
WARNING
verizon
This is an ACCESS POINT to an area
with transmitting antennas.
Obey all postings and boundaries beyond this point.
Call Verizon Wireless at 1-800-264-6620 for more information.
STATE: ______ SWITCH: _________________
SITE ID: _______________________________
NOTICE SIGNAGE AND CONTACT INFO
INFORMATION
verizon
B
C
D
E
A
E
SCALE: 1" = 10'-0" (11X17) 0' 5' 10' 20'
SCALE: 1" = 5'-0" (24X36)
A
E
A
B
A
C
A
C
A
C
A
C
NEW VZW RF SAFETY
SIGNAGE ON BOTTOM
OF UPPER ROOF
ACCESS LADDER
NEW VZW RF SAFETY
SIGNAGE ON ROOF
ACCESS HATCH
EX. BUILDING
UPPER ROOFTOP
Z4
RF SAFETY
SIGNAGE
(PAINTED TO MATCH
DOWNSPOUTS)
C.L. OF ANTENNAS
ELEV. 36'-0"
C.L. OF ANTENNAS
ELEV. 36'-0"
NEW VZW ACCESS LADDER W/ SECURITY PANEL
AND KNOX LOCK BOX, TO UPPER LEVEL ROOF
(PAINT GREEN TO MATCH EX. TRIM)
EX. LIGHTPOLE
EX. GRADE
ELEV. 0'-0" (4963'-0)
T.O. SCREEN / CABINETS
ELEV. 27'-3"
EX. GRADE
ELEV. 0'-0" (4963'-0)
7'-6"
NEW VZW ANTENNAS CONCEALED BEHIND RF TRANSPARENT
SCREEN WALL, (PAINTED TO MATCH EX. BUILDING 8X8 FLAT FACE
CMU, AND ADD HEAVY STUCCO TEXTURE TO SIMULATE CONCRETE.
JOINTS BETWEEN FACES TO BE UNTEXTURED AND PAINTED WHITE
TO MATCH EX. BUILDING MORTAR JOINTS)
ADD FRP STRIP PAINTED GREEN
TO MATCH EX. FLASHING
NEW VZW ANTENNAS CONCEALED BEHIND RF TRANSPARENT SCREEN WALL,
(PAINTED TO MATCH EX. BUILDING 8X8 FLAT FACE CMU, AND ADD HEAVY
STUCCO TEXTURE TO SIMULATE CONCRETE. JOINTS BETWEEN FACES TO BE
UNTEXTURED AND PAINTED WHITE TO MATCH EX. BUILDING MORTAR JOINTS)
ADD FRP STRIP PAINTED GREEN
TO MATCH EX. FLASHING
NEW VZW EQUIPMENT CABINETS ON PLATFORM
CONCEALED BEHIND LOUVER SCREEN
T.O. SCREEN / CABINETS
ELEV. 27'-3"
NEW VZW EQUIPMENT
CABINETS ON PLATFORM
CONCEALED BEHIND
LOUVER SCREEN
ACCESS LADDER (PAINT
GREEN TO MATCH EX. TRIM)
NEW VZW ANTENNAS CONCEALED BEHIND RF TRANSPARENT SCREEN
WALL. CONCEALMENT WALLS TO PAINTED TO MATCH EX. BUILDING 8X8
FLAT FACE CMU, AND ADD HEAVY STUCCO TEXTURE TO SIMULATE
CONCRETE. JOINTS BETWEEN FACES TO BE UNTEXTURED AND
PAINTED WHITE TO MATCH EX. BUILDING MORTAR JOINTS)
NEW VZW WALL MOUNTED 2" CONDUIT (PAINTED
GREEN TO MATCH EX. DOWNSPOUTS)
NEW VZW ACCESS LADDER W/
SECURITY PANEL AND LOCK, TO
UPPER LEVEL ROOF (PAINT
GREEN TO MATCH EX. TRIM)
C.L. ANTENNAS
ELEV. 36'-0"
C.L. ANTENNAS
ELEV. 36'-0"
EX. GRADE
ELEV. 0'-0" (4963'-0)
ADD FRP STRIP (PAINTED GREEN
TO MATCH EX. FLASHING)
ADD FRP STRIP
PAINTED GREEN TO
MATCH EX. FLASHING
NEW VZW EQUIPMENT CABINETS
ON PLATFORM CONCEALED
BEHIND LOUVER SCREEN
T.O. SCREEN / CABINETS
ELEV. 27'-3"
TO NEW ELEVATED EQUIPMENT
PLATFORM CONCEALED BEHIND
NEW LOUVER SCREEN
NEW VZW ANTENNAS,
(SEE DET. 3/Z2)
NOTE: EXACT DESIGN OF
PLATFORM AND ANTENNA
MOUNTS T.B.D. PER
STRUCTURAL ASSESSMENT
(2) NEW VZW OVPs
(2) NEW VZW HYBRID
CABLES TO RUN
INSIDE COAX TRAY
(ON ELEVATED
SLEEPERS) TO
UPPER ROOF,
VERTICAL IN
CONDUIT (PAINTED
TO MATCH EX.
WALL)
NEW VZW U/G FIBER RUN
(INSIDE EASEMENT)
NEW VZW 5' UTILITY
EASEMENT
NEW VZW FIBER H.H.
NEAR PROPERTY LINE,
(EXACT LOCATION T.B.D.)
NEW VZW CAGED ACCESS
LADDER TO LOWER LEVEL
ROOF (PAINT GREEN TO
MATCH EX. TRIM)
NEW VZW ACCESS LADDER
W/ SECURITY PANEL AND
KNOX LOCK, TO UPPER
LEVEL ROOF (PAINT GREEN
TO MATCH EX. TRIM)
EX. BUILDING
ENTRANCE
NEW VZW ILC CABINET
MOUNTED TO UNISTRUT ON
NEW VZW 127 S.F. LEASE AREA COLUMNS
EX. LIGHTPOLE
NEW VZW EQUIPMENT CABINETS
ON ELEVATED PLATFORM BEHIND
CONCEALMENT LOUVER SCREEN
EX. CMU PARAPET WALL
EX. CMU PARAPET WALL
(2) NEW VZW WIDE-FLANGE
BEAMS INBED IN EXISTING
PARAPET WALL. (EXACT
LOCATION AND DETAILING TO BE
DETERMINED)
NEW VZW STEEL COLUMNS
(TYP)(DETAILING TO BE
DETERMINED)
NEW VZW ANODIZED
ALUMINUM LOUVER PANELS
NEW VZW PARAPET
STEP-OVER
NEW VZW 12" CABLE TRAY
ON ELEVATED SLEEPERS
NEW VZW FIBER
RUN IN TRAY
(2) NEW VZW LOW
INDUCTANCE HYBRID
CABLES IN TRAY
NEW VZW POWER RUN IN
CONDUIT IN TRAY
9'-6"
13'-3"
1'-9 1/2"
1'-6"
3'-0"MIN.
EX. ROOF
EX. ROOF
5'-0"
NEW VZW ADHERED
WALKWAY PAD (TYP)
NEW VZW ADHERED
WALKWAY PAD (TYP)
RIVERSIDE AVE.
1
Z3.1
1
Z3.2
2
Z3.2
2
Z3.1
NEW VZW ANTENNAS MOUNTED ON
STEEL PLATFORM AND CONCEALED
INSIDE RF TRANSPARENT SCREEN
WALLS PAINTED TO MATCH
EXISTING BUILDING, (SEE 3/Z2)
NEW VZW 15' ACCESS
EASEMENT FROM R.O.W.
NEW VZW 5' UTILITY
EASEMENT
NEW VZW ACCESS
LADDER W/ SECURITY
PANEL AND LOCK, TO
UPPER LEVEL ROOF
(PAINT GREEN TO
MATCH EX. TRIM)
NEW VZW FIBER H.H.
NEAR PROPERTY LINE,
(EXACT LOCATION T.B.D.)
NEW VZW HYBRID RUN
INSIDE CABLE TRAY. TO
VERTICAL CONDUIT AT
UPPER ROOF WALL
15'-0"
EX. PROPERTY LINE,
TYP. (SEE LS1)
EX. PROPERTY LINE,
TYP. (SEE LS1)
EXISTING R.O.W.
5'-0"
NOTE:
NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE
OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY
OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THE SAME
BUILDING, STRUCTURE OR LOCATION. WIRELESS TELECOMMUNICATION FACILITY OR
EQUIPMENT OWNERS OR LESSEES OR EMPLOYEES THEREOF, AND APPLICANTS FOR
THE APPROVAL OF PLANS FOR THE INSTALLATION OF SUCH FACILITIES OR
EQUIPMENT, SHALL COOPERATE IN GOOD FAITH TO ACHIEVE CO_LOCATION OF
WIRELESS TELECOMMUNICATION FACILITIES AND EQUIPMENT. ANY APPLICATION FOR
THE APPROVAL OF A PLAN FOR THE INSTALLATION OF WIRELESS
TELECOMMUNICATION FACILITIES OR EQUIPMENT SHALL INCLUDE DOCUMENTATION
OF THE APPLICANT'S GOOD FAITH EFFORTS TOWARD SUCH COOPERATION.
13'-5±
SEPERATION BETWEEN WATER SERVICE
AND PROPOSED FIBER RUN
APPLICANT:
VERIZON
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS
AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY
THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE
PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.
DRAWING SCALES SHOWN ARE ACCURATE WHEN PLOTTED ON 11"X17"
SHEET. FOR 24"X36" SHEETS USE APPROPRIATE SCALE FACTOR 2X
THAT OF SCALE SHOWN OR CONTACT CENTERLINE SOLUTIONS FOR
FURTHER INFORMATION. DIMENSIONS SHOWN TAKE PRECEDENCE.
CALL 811 TWO BUSINESS DAYS BEFORE DIGGING. THE CONTRACTOR
SHALL NOTIFY ONE CALL TO LOCATE ALL UNDERGROUND FACILITIES
BEFORE DIGGING. IT SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR TO STAY CLEAR OF ALL UNDERGROUND FACILITIES.
THESE DRAWINGS MAY NOT SHOW ALL UNDERGROUND PIPING AND
UTILITIES. THE CONTRACTOR SHALL EXERCISE EXTREME CARE DURING
ALL EXCAVATION AND OTHER CONSTRUCTION ACTIVITIES.
VERIZON WIRELESS IS RESPONSIBLE FOR ALL UTILITY LOCATES AND
UTILITY RELOCATIONS REQUIRED FOR THIS INSTALLATION. VERIZON
WIRELESS WILL SCHEDULE AND COORDINATE ALL WORK WITH THE
OWNER TO ENSURE NO DISRUPTION TO OWNERS OPERATIONS.
VERIZON WIRELESS SHALL BE ABBREVIATED "VZW" THROUGHOUT.
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
303-993-3293
WWW.CENTERLINESOLUTIONS.COM
3131 S. VAUGHN WAY, SUITE 550
AURORA, CO 80014
PROJECT INFORMATION:
PLANS PREPARED BY:
LICENSURE NO:
SITE NAME:
REV: DATE: DESCRIPTION: BY:
DRAWN BY: CHK BY: APV BY:
SHEET TITLE:
SHEET NUMBER:
T1
TITLE SHEET
ISSUED FOR: ZONING
FTC EAST DALE
901 RIVERSIDE AVE.
FT. COLLINS, CO 80524
LARIMER COUNTY
TC BB KS
1 03/07/18 90% ZONING TC
2 04/09/18 90% ZONING REV A BB
3 05/11/18 100% ZONING BB
4 10/02/18 100% ZONING REV A BB
5 12/21/18 100% ZONING REV B BB
PRELIMINARY -
NOT FOR
CONSTRUCTION
CIVIL SURVEYOR:
DALEY LAND SURVEYING, INC.
17011 LINCOLN AVENUE STE. 361
PARKER, CO 80134-3144
ROB DALEY, PLS
PH: 303.953.9841
SITE ACQUISITION:
CENTERLINE SOLUTIONS, LLC
JENNIFER DANIELS
PH: 303.993.3293 EXT. 1216
RF ENGINEER:
VERIZON WIRELESS
RAM NANDIRAJU
PH. 303.873.2693 M:720.467.0443
CONSTRUCTION MANAGER:
VERIZON WIRELESS
KENT MCDERMOTT
406.941.2110
UC1 UTILITY COORDINATION PLAN
A&E FIRM:
CENTERLINE SOLUTIONS, LLC
BRAD BRYANT, PM
PH: 303.993.3293 X1383
LAND SURVEY
ENGINEER OF RECORD:
CENTERLINE SOLUTIONS, LLC
KHRISTOPHER SCOTT, PE
PH: 303.993.3293
Z1 OVERALL SITE PLAN
Z3.1 SOUTHEAST & NORTHEAST ELEVATIONS
Z3.2 NORTHWEST & SOUTHWEST ELEVATIONS
Z2 ENLARGED SITE PLAN, EQUIPMENT PLAN & ANTENNA DETAIL
SITE LOCATION
Z4 RF SAFETY SIGNAGE
PH1 PHOTOSIMULATIONS NORTH & SOUTHEAST VIEWS
PH2
LS3 LAND SURVEY
PHOTOSIMULATIONS EAST VIEW
FCN1 CITY OF FT. COLLINS GENERAL NOTES
GN1 GENERAL NOTES
GN2 GENERAL NOTES (SHEET 2 OF 4)
GN3 GENERAL NOTES (SHEET 3 OF 4)
GN4 GENERAL NOTES (SHEET 4 OF 4)
POWER COMPANY:
TELCO COMPANY:
CONTACT: TBD
WK: / CELL:
CONTACT: TBD
WK: / CELL:
UTILITIES
TBD
IN-HOUSE
SIGNATURES
OWNER'S CERTIFICATION
THE UNDERSIGNED DOES/DO HEREBY CERTIFY THAT I/WE ARE THE LAWFUL
OWNERS OF REAL PROPERTY ON THIS SITE PLAN AND DO HEREBY CERTIFY
THAT I/WE ACCEPT THE CONDITIONS AND RESTRICTIONS SET FORTH ON SAID
SITE PLAN.
OWNER DATE
NOTARY CERTIFICATE
STATE OF COLORADO ss.)
COUNTY OF )
SUBSCRIBED and sworn to before this _______day of _______________20____
by.
WITNESS my hand and official seal. My commision expires:
Notary Public_______________________
DIRECTOR OF PLANNING
APPROVED BY THE DIRECTOR OF PLANNING OF THE CITY OF FORT COLLINS,
COLORADO, THIS _____________DAY OF________________________A.D. 20_____
CDNS DIRECTOR