Loading...
HomeMy WebLinkAboutPOUDRE GARAGE - BDR160007 - SUBMITTAL DOCUMENTS - ROUND 2 - SITE PLANEX. ELEC VAULT T EX. ELEC VAULT Fence (New) Metal Gate - Bronze Utility and Trash Yard Existing Adjacent Commercial Building (not part of project) Existing Adjacent Commercial Building (not part of project) Existing walkway for adjacent building OAK STREET 100' ROW REMINGTON STREET 100' ROW (E) Curb & Gutter (E)Street Tree in R.O.W. Preserve and protect (E)Street Tree in R.O.W. Preserve and protect (E) Fire hydrant on west side of Remington Street (E) Striping for on street parking New parkway turf area New Planting Areas New Sidewalk Expansion of (E) Curb Cut Enclosed Bicycle Storage 2 Tier Rack accomidates 6 bicycles (E) Sidewalk Rain Garden 8'-6" 8'-6" 18'-0" (E)Street Tree in R.O.W. Preserve and protect Existing Building Floor Area = 4,902 S.F. New Addition Floor Area = 8,254 S.F. Bike Parking Racks (4 bicycles) (E) Striping for handicap parking 8'-6" 8'-6" 18'-0" New Planting Areas (E) Sidewalk 20' ALLEY 01 D1 1'-0" 1'-8 1/2" 3" 3'-6" 3'-2" 5'-3" 34'-1" Land Use Data • Existing Zoning: D(Downtown) Old City Center Sub District, Transit- oriented development (TOD) Overlay Zone • Residential Sign Dist.: Development is NOT in Residential Sign District • Proposed Land Use: Mixed Use (Commercial/Residential) • Max. Building Height Permitted: 56' or 4 stories • Max. Building Height Proposed: 45' • Gross Site Area: 7,000 S.F. (.16 AC.) • Net Site Area: 7,000 S.F. (.16 AC.) • Estimated Floor Area: 13,156 S.F. • Floor Area Ratio: 1.88 • Public R.O.W: 0 S.F. (0 Acres) Dwelling Units Studio One Bedroom Apartment One Bedroom Apartment with Den Total Total Bedrooms = 4 Quantity 2 2 2 6 Residential Density Gross Residential Density:66.7dua (# of units)/Gross Residential Acreage 6/.09 = 66.7 Net Residential Density:66.7dua (# of units)/Net Residential Arcreage 6/.09 = 66.7 Gross Residential Acreage=(Site Acreage)-(Non-Residential Acreage) .09=.16-.07 Net Residential Acreage=(Gross Residential Acreage)-(Land Dedicated to Other Uses LUO 3.18.8(B)(1)) .09=.09-0 Site Coverage Building Coverage Drives and Parking Landscape Area and Walks (Open Space) Public R.O.W. Active Recreational Use Total Area 5,941 S.F. 114 S.F. 945 S.F. 0 S.F. 0 S.F. 7,000 S.F. Percent 85% 1.5% 13.5% 0% 0% 100% Parking (Residential) Long-Term Parking Stalls Compact Parking Stalls (tandem, not counted in required) ADA Accessible Parking Stalls Total Total required based on 6 units (of one bedroom or less) x .75 = 4.5 (5) *Tandem spaces not included in provided total required ** Based on Demand Mitigation Strategy listed: -Offsite Parking = 1:1, Either an Old Town Garage or Oak/Remington Lot will be provided. *** There are no accessible residential units in the development. There is no demand for prescribed accessible stall. Required 4.5 - - 5(4)** Provided 4 4* 0*** 4 Parking (General Retail) Total *3.2.2(K)(2)(b) Existing Buildings Exemption: Change in use of an existing building shall be exempt from minimum parking requirements. Required 2 Provided 0* Parking (General Office) Total *3.2.2(K)(2)(b) Existing Buildings Exemption: Change in use of an existing building shall be exempt from minimum parking requirements. Required 1 Provided 0* Parking 1 Handicap Space Required (1-25 total spaces in lot = 1 required accessible space For site) 1 Existing on street accessible space currently exists in front of building. Bicycle Parking Use Multi-family Residential General Retail General Office Requirement 1 per bedroom 1/4,000 sf minimum 4 1/4,000 sf minimum 4 % enclosed/% racks 60%/40% 20%/80% 20%/80% Required 6 4 4 Enclosed 4 1 1 Rack 2 1 1 Provided Enclosed 6 Rack 4 Site Plan Notes: 1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. N/A 7. N/A 8. N/A 9. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT- CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 10. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 11. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 12. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 13. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 14. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS’ ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 15. N/A 16. N/A 17. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 18. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 19. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY‑FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX‑INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. Director of Community Development and Neighborhood Services Approved by the Director of Community Development and Neighborhood Services of the City of Fort Collins, Colorado on this ______ day of ________________, A.D., 20 ___________________________________________________ _____________ Director of Planning Ownership Certification Poudre Garage, LLC. By:__________________________________ Tricia Diehl, Memeber STATE OF COLORADO ) )ss. COUNTY OF LARIMER ) The foregoing instrument was acknowledged before me this ______ day of ___________________, 2016, by Tricia Diehl, as Member of Poudre Garage, LLC Witness my hand and official seal. My Commission Expires: _______________________ ______________________________________________ Notary Public By:__________________________________ Patty Spencer, Memeber STATE OF COLORADO ) )ss. COUNTY OF LARIMER ) The foregoing instrument was acknowledged before me this ______ day of ___________________, 2016, by Patty Spencer, as Member of Poudre Garage, LLC Witness my hand and official seal. My Commission Expires: _______________________ ______________________________________________ Notary Public Legal Description LOT 1, POUDRE GARAGE 6'-11" New parkway. Landscape buffer. Existing parkway. Shaded areas to have standard broom finish. Typical sidewalk conrete to have sandscape finish. Landscape buffer. Convex Mirror EAST DR UNIVERSITY AVE W PITKIN ST SOUTH DR UNIVERSITY AVE W PITKIN ST JEFFERSON ST. WILLOW ST. LINDEN ST. N. COLLEGE AVE. E. LINCOLN AVE. BUCKINGHAM ST. E. VINE DR. OLD TOWN BASIN CACHE LA POUDRE BASIN MOUNTAIN AVE. E. MULBERRY ST S. COLLEGE AVE. LAPORTE AVE. MAPLE AVE. S. MASON AVE. S. HOWES AVE. E. MYRTLE ST E. LAUREL ST E. OAK ST S. REMINGTON ST PROJECT LOCATION TOD Zoning: (D) Downtown, Old City Center Sub District POUDRE GARAGE © 2016 [au]workshop, llc FORT COLLINS, CO 5/24/2016 12:00:59 PM 01 Site Plan 05/24/16 1" = 20'-0" Site Plan 0' 10' 20' 40' 80' N D1 1" = 10'-0" Driveway Plan 1" = 2000'-0" Vicinity Map BDR Sheet Index Sheet Number Sheet Name 01 Site Plan 02 Landscape Plan 03 Floor Plans 04 Floor Plans 05 Shadow Studies 06 Shadow Studies 07 Elevations 08 Materials 09 Perspectives & Renderings 10 Perspectives & Renderings 11 Setbacks