Loading...
HomeMy WebLinkAboutPOUDRE GARAGE - BASIC DEVELOPMENT REVIEW - BDR160007 - SUBMITTAL DOCUMENTS - ROUND 1 - PHOTOMETRIC PLANNORTH C.O. ELEC BRKR AC AC E 20' ALLEY REMINGTON STREET (100' PUBLIC R.O.W.) OAK STREET (100' PUBLIC R.O.W.) 2 STORY BRICK 1 STORY BRICK 1 STORY BLOCK RAMP W/ HANDRAIL ELEC VAULT T T Scale: 1"=10' 0 5 10 20 REMOVE EXISTING OVERHEAD ELECTRICAL FEED. COORDINATE WITH CIVIL REMOVE EXISTING WOOD POLE AND POLE MOUNTED FIXTURE. COORDINATE WITH CIVIL EXISTING FIXTURES TO BE REFURBISHED, SEE DETAILS, SHEET E-102 REMOVE EXISTING UTILITY METER AND HOUSE PANEL REMOVE TELEPHONE AND CATV FEEDS 1 1 1 REMOVE EXISTING TELEPHONE PEDESTAL. COORDINATE WITH CIVIL 1 REMOVE EXISTING WALL PACK AND ASSOCIATED SURFACE MOUNTED CONDUIT. FLAG NOTES - THIS SHEET ONLY REMOVE WOOD BASE PLATE AND REPLACE WITH SHEET METAL COVER REFURBISHED AND PAINT DARK BRONZE METAL ENDPLATES CLEAN GLASS LENS REWORK EXISTING INCANDESCENT LIGHT SOURCE AND REPLACE WITH LED MODULE EXISTING FIXTURE TO BE REFURBISHED NTS 1" = 10'-0" 20' ALLEY REMINGTON STREET (100' PUBLIC R.O.W.) OAK STREET (100' PUBLIC R.O.W.) 2 STORY BRICK 1 STORY BRICK 1 STORY BLOCK RAMP W/ HANDRAIL ELEC VAULT T T PB Scale: 1"=10' 0 5 10 20 NORTH P APPROXIMATE LOCATION OF EXISTING TRANSFORMER P P P P P PROVIDE PULLBOX AT FOURTH 90 DEGREE BEND. PROVIDE WITH HIGH TRAFFIC RATED COVER P P NEW METER STACK. MAINTAIN 5'-0" SEPARATION FROM NEW GAS METERS APPROXIMATE LOCATION OF NEW MAIN TTB T T RECONNECT TELEPHONE AND CATV SERVICE. COORDINATE WITH CIVIL 2" CONDUIT FOR TELEPHONE AND 2" CONDUIT FOR CATV AA BB BB AA AA AA BB EXISTING FIXTURES TO BE REFURBISHED, SEE DETAIL, THIS SHEET ....................... TYPE 'AA' 1" = 10'-0" Electrical Site Plan - New 6801 W. 20th Street, Suite #212 GREELEY, COLORADO 80634 GREELEY: (970) 330-3266 MMMM MMMMMMM ELECTRICAL ONE-LINE M EXISTING WEATHERHEAD ON BUILDING EXISTING METER EXISTING HOUSE PANEL 150A MCB EXISTING EXISTING REMOVED EXISTING FT. COLLINS LIGHT AND POWER 120/208 VOLT, 3PH, 4 WIRE, 150 KVA PAD MOUNT TRANSFORMER EXISTING POWER POLE EXISTING POWER POLE 1 GGGG G 5678910 GGGG 10 10 'H' PNL HOUSE 'R1' PNL RETAIL 600A JJN 600/3 100/3 200/3 200/3 100/3 100/3 100/2 100/2 100/2 'R2' PNL RETAIL 'R3' PNL RETAIL 'R4' PNL OFFICE 'A' PNL 1 BED/ DEN 'B' PNL 1 BED/ DEN 'C' PNL STUDIO 100/2 10 'D' PNL STUDIO 100/2 10 'E' PNL 1 BED 100/2 10 'F' PNL 1 BED GANGABLE GROUP METERING, NEMA 3R, 600 AMP MLO, 200 AMP METER SOCKETS 120/208V, 3 PHASE, 4 WIRE OUT, BRACED FOR 100,000 AIC, METERING AND PANELS SHALL BE SERIES RATED TO ALLOW 10,000 AIC BREAKERS IN RETAIL, APTS, AND HOUSE PANELS. PROVIDE DATA AT SHOP DRAWINGS AND PROVIDE 22 LABELING OF SERIES RATING ON ALL PANELS. MIN 10'-0" 3/4" X 10'-0" DRIVEN GRD ROD 3 BLDG STEEL 3 COLD WATER PIPE 4 N.TS. NEW X AIC =XXXX VERIFY AIC WITH POWER CO, IF FAULT CURRENT EXCEEDS XXXXXX NOTIFY ELECTRICAL ENGINEER CAD WELD TO REBAR UFER GROUND PIPE X V.D. = 2.2% DESCRIPTION FEEDER SCHEDULE KEY 1 2 3 4 5 6 7 8 9 10 3 RUNS[(4 #500 KCMIL THWN CU) 4"C.] (#6 CU GRD) 3/4"C. (#2/0 CU GRD) 3/4"C. (#4 CU GRD) 3/4"C. (4 #1 THWN CU & #8 CU GRD) 2"C. (4 #3/0 THWN CU & #6 CU GRD) 2 1/2"C. (4 #3/0 THWN CU & #6 CU GRD) 2 1/2"C. (4 #1 THWN CU & #8 CU GRD) 2"C. (4 #1 THWN CU & #8 CU GRD) 2"C. (3 #1 THWN CU & #8 CU GRD) 1 1/2"C. GROUP METERING ELEVATION FINAL GRADE NOTE: 1. EACH METER MUST BE PERMANENTLY LABELED TO IDENTIFY CUSTOMER ADDRESS. 2. LABEL MUST BE CONSTRUCTED OF ENGRAVED BRASS. 3. FAULT LIMITING DISCONNECTS SHALL BE INSTALLED ON THE LINE SIDE OF THE METER. FUSE SIZE AND TYPE SHALL LIMIT FAULT CURRENT TO THE METER HOUSING TO 10,000 AMPS OR LESS PER THE NEC. 4. THE FUSED DISCONNECT SHALL BE PURCHASED AND INSTALLED BY THE CUSTOMER AND SHALL INCLUDE PROVISIONS FOR A FORT COLLINS LIGHT AND POWER COMPANY SEAL. 5. SEALS WILL BE USED BY FORT COLLINS LIGHT AND POWER COMPANY TO SECURE THE ENCLOSURE FROM UNAUTHORIZED ENTRY BUT ALLOW THE CUSTOMER EMERGENCY ACCESS FOR FUSE REPLACEMENT. N.T.S. SEALABLE ENCLOSURE MIN 7 1/2" MIN 8 1/2" 600/2 MFS MAX 75" MIN 24" BREAKERS SHALL BE SERIES RATED FOR THE AVAILABLE FAULT CURRENT VALUES SHOWN. SERIES RATING SPECIFICATION WHERE SERIES RATING COMBINATIONS ARE SHOWN ON THE PLANS, THE LOADSIDE CIRCUIT BREAKERS SUPPLIED SHALL BE TEST AND LISTED AS A SERIES COMBINATION WITH THE LINE SIDE FEEDER FUSES PER THE PLANS. PANELBOARDS WITH SERIES RATED LOADSIDE CIRCUIT BREAKERS SHALL HAVE A MANUFACTURER'S LABEL STATING THE LISTING FOR THE SERIES COMBINATION INTERRUPTING RATING FOR THE LOADSIDE CIRCUIT BREAKERS AND THE LINESIDE FUSE (OR CIRCUIT BREAKER) COMBINATION, IN COMPLIANCE WITH NEC SECTION 240-86. THIS SERIES RATING SHALL BE EQUAL TO OR GREATER THAN THE AVAILABLE SHORT-CIRCUIT CURRENT. WHERE SERIES RATED COMBINATIONS ARE UTILIZED, THE ELECTRICAL CONTRACTOR SHALL AFFIX FIELD INSTALLED LABELS TO THE LOADSIDE CIRCUIT BREAKER PANELBOARD AND FEEDER SWITCH/PANELBOARD/SWITCHBOARD, IN COMPLIANCE WITH NEC SECTION 110-22. AS REQUIRED IN SECTION 110-22, THE LOADSIDE PANELBOARD/SWITCHBOARD LABEL SHALL BE FIELD MARKED WITH THE SHORT-CIRCUIT RATING OF THE SERIES COMBINATION, TYPE CIRCUIT BREAKER FOR REPLACEMENT, PART NUMBER FOR THE SERIES RATED LINESIDE, FEEDER FUSES AND LOCATION/NAME OF THIS FUSE SWITCH/PANELBOARD/SWITCHBOARD. THE PANEL/SWITCH WITH THE LINESIDE FUSES (OR CIRCUIT BREAKER) SHALL BE FIELD MARKED WITH SHORT-CIRCUIT RATING OF THE SERIES COMBINATION, PART NUMBER FOR FUSE (OR CIRCUIT BREAKER) REPLACEMENT AND THE LOCATION/NAME OF LOADSIDE, SERIES RATED PANELBOARD/SWITCHBOARD. IF THE MANUFACTURER/SUPPLIER/INSTALLER CANNOT SUPPLY TESTED AND LISTED SERIES RATED COMBINATIONS OF THE SPECIFIED LOADSIDE CIRCUIT BREAKERS WITH THE SPECIFIED LINE SIDE FUSES, IT IS THEIR RESPONSIBILITY TO PROVIDE LOADSIDE CIRCUIT BREAKERS THAT HAVE FULLY RATED INTERRUPTING RATINGS EQUAL TO OR GREATER THAN THE SHORT-CIRCUIT CURRENT AVAILABLE AT THE LOADSIDE CIRCUIT BREAKERS. SERIES RATING : METER STACKS WITH SERIES RATED LOADSIDE CIRCUIT BREAKERS SHALL HAVE A MANUFACTURER'S LABEL STATING THE LISTING FOR THE SERIES COMBINATION INTERRUPTING RATING FOR THE LOADSIDE CIRCUIT BREAKER, IN COMPLIANCE WITH NEC SECTION 240-86. THIS SERIES RATING SHALL BE EQUAL TO OR GREATER THAN THE AVAILABLE SHORT-CIRCUIT CURRENT. WHERE SERIES RATED COMBINATIONS ARE UTILIZED, THE ELECTRICAL CONTRACTOR SHALL AFFIX FIELD INSTALLED LABELS TO THE LOADSIDE CIRCUIT BREAKER PANELBOARD AND AND METER STACK LOAD CENTERS, IN COMPLIANCE WITH NEC SECTION 110-22. IF THE MANUFACTURER/SUPPLIER/INSTALLER CANNOT SUPPLY TESTED AND LISTED SERIES RATED COMBINATIONS OF THE SPECIFIED LOADSIDE CIRCUIT BREAKERS, IT IS THEIR RESPONSIBILITY TO PROVIDE LOADSIDE CIRCUIT BREAKERS THAT HAVE FULLY RATED INTERRUPTING RATINGS EQUAL TO OR GREATER THAN THE SHORT-CIRCUIT CURRENT AVAILABLE AT THE LOADSIDE CIRCUIT BREAKERS. 1. 2. 3. DARK BRONZE TYPE 'BB' 6801 W. 20th Street, Suite #212 GREELEY, COLORADO 80634 GREELEY: (970) 330-3266 FACSIMILE: 1 (888) 551-1062 & ASSOCIATES, LLC ELECTRICAL ENGINEERS - PLOT DATE A A 1 2 3 4 5 5 4 3 2 1 B C D A B C D issue date: project #: T - 970.430.5220 405 linden street fort collins, co, 80524 © 2015 www.auworkshop.co 3/1/2016 3:54:43 PM E‐400 1504 ELECTRICAL ONE-LINE Poudre Garage 148 Remington St Fort Collins, Co 80524 Poudre Garage, LLC Project Status 03/01/2016 FACSIMILE: 1 (888) 551-1062 & ASSOCIATES, LLC ELECTRICAL ENGINEERS - PLOT DATE A A 1 2 3 4 5 5 4 3 2 1 B C D A B C D issue date: project #: T - 970.430.5220 405 linden street fort collins, co, 80524 © 2015 www.auworkshop.co 3/1/2016 3:54:42 PM E‐101 1504 ELECTRICAL SITE PLAN - NEW Poudre Garage 148 Remington St Fort Collins, Co 80524 Poudre Garage, LLC Project Status 03/01/2016 Electrical Site Plan - Demo DRAWING INDEX Sheet Number Sheet Name E-100 ELECTRICAL SITE PLAN - DEMO E-101 ELECTRICAL SITE PLAN - NEW E-400 ELECTRICAL ONE-LINE 6801 W. 20th Street, Suite #212 GREELEY, COLORADO 80634 GREELEY: (970) 330-3266 FACSIMILE: 1 (888) 551-1062 & ASSOCIATES, LLC ELECTRICAL ENGINEERS - PLOT DATE A A 1 2 3 4 5 5 4 3 2 1 B C D A B C D issue date: project #: T - 970.430.5220 405 linden street fort collins, co, 80524 © 2015 www.auworkshop.co 3/1/2016 3:54:41 PM E‐100 1504 ELECTRICAL SITE PLAN - DEMO Poudre Garage 148 Remington St Fort Collins, Co 80524 Poudre Garage, LLC Project Status 03/01/2016