HomeMy WebLinkAboutTRILBY DITCH RELOCATION - BDR180037 - SUBMITTAL DOCUMENTS - ROUND 1 - DRAINAGE REPORTNovember 6, 2018 Shane Boyle City of Fort Collins Utilities 700 Wood Street Fort Collins, CO 80526 RE: Louden Ditch Piping Shane, This letter is to address impacts created by piping the Louden Ditch from Skyway Drive to Trilby Road. The existing Louden Ditch is a defined grassed lined channel that varies in depth and capacity. At the upstream end of this section of the Louden Ditch is a 30” corrugated metal pipe that runs under Trilby Road at a slope of 0.7%. At the downstream end of this section of the Louden Ditch is a 24” corrugated metal pipe that runs under Skyway Drive at a slope of approximately 0.8%. The existing ditch carries a maximum of 10 cfs of irrigation flows per the Ditch Company. A calculation was completed to show that the irrigation ditch can carry a maximum of 28.2 cfs before overtopping near Station 1+00. This calculation is attached. A UD Sewer model was completed showing the impact of 28.2 cfs in the proposed 30” pvc pipe and the results of this calculation are attached. Calculations were completed to show the capacity of the existing corrugated metal pipes at each end of this section of the Ditch. The upstream 30” cmp under Trilby was shown to have a capacity of just over 20 cfs. The downstream 24” cmp under Skyway was shown to have a capacity of just under 12 cfs. This shows that the maximum flow that can be introduced to the Louden Ditch flowing under Trilby is 20.3 cfs but the downstream culvert under Skyway cannot convey more than 12cfs. This shows that the proposed 30” pvc pipe is adequate to convey the maximum flows that will be introduced to the pipe at Trilby Road. A second UD Sewer model was completed to show the impact of 20.3 cfs and this proposed 30” pvc can convey that flow. 700 Automation Drive, Unit I Windsor, CO 80550 Phone: 970-686-6939 Fax: 970-686-1188 The attached calculations support the conclusion that piping this section of the Louden Ditch will not have a negative impact on the capacity of this conveyance. The flow restriction on this section of the Louden Ditch appear to be the upstream 30” cmp and, more so, the downstream 24” cmp. If you have any questions or comments, please don’t hesitate to contact me. Sincerely, Patricia Kroetch P.E. Project: Channel ID: Design Information (Input) Channel Invert Slope So = 0.0017 ft/ft Manning's n n = 0.037 Bottom Width B = 0.00 ft Left Side Slope Z1 = 1.59 ft/ft Right Side Slope Z2 = 1.98 ft/ft Freeboard Height F = 0.00 ft Design Water Depth Y = 2.88 ft Normal Flow Condtion (Calculated) Discharge Q = 28.18 cfs Froude Number Fr = 0.28 Flow Velocity V = 1.90 fps Flow Area A = 14.81 sq ft Top Width T = 10.28 ft Wetted Perimeter P = 11.80 ft Hydraulic Radius R = 1.25 ft Hydraulic Depth D = 1.44 ft Specific Energy Es = 2.94 ft Centroid of Flow Area Yo = 0.95 ft Specific Force Fs = 0.98 kip Normal Flow Analysis - Trapezoidal Channel Louden Ditch Piping Station 1+00 Ex Channel sta 1.xls, Basics 11/6/2018, 11:02 AM Project: Channel ID: Design Information (Input) Bottom Width B = 0.00 ft Left Side Slope Z1 = 1.96 ft/ft Right Side Slope Z2 = 2.24 ft/ft Design Discharge Q = 28.20 cfs Critical Flow Condition (Calculated) Critical Flow Depth Y = 2.18 ft Critical Flow Area A = 9.98 sq ft Critical Top Width T = 9.16 ft Critical Hydraulic Depth D = 1.09 ft Critical Flow Velocity V = 5.94 fps Froude Number Fr = 1.00 Critical Wetted Perimeter P = 10.14 ft Critical Hydraulic Radius R = 0.98 ft Critical (min) Specific Energy Esc = 2.73 ft Centroid on the Critical Flow Area Yoc = 0.34 ft Critical (min) Specific Force Fsc = 0.89 kip Critical Flow Analysis - Trapezoidal Channel Louden Ditch Piping Station 1+00 Ex Channel sta 1.xls, Basics 11/6/2018, 11:02 AM Project: Pipe ID: Design Information (Input) Pipe Invert Slope So = 0.0070 ft/ft Pipe Manning's n-value n = 0.0220 * Pipe Diameter D = 30.00 inches Design discharge Q = 20.30 cfs Full-flow Capacity (Calculated) Full-flow area Af = 4.91 sq ft Full-flow wetted perimeter Pf = 7.85 ft Half Central Angle Theta = 3.14 radians Full-flow capacity Qf = 20.33 cfs Calculation of Normal Flow Condition Half Central Angle (0<Theta<3.14) Theta = 2.26 radians Flow area An = 4.30 sq ft Top width Tn = 1.93 ft Wetted perimeter Pn = 5.65 ft Flow depth Yn = 2.05 ft Flow velocity Vn = 4.72 fps Discharge Qn = 20.30 cfs Percent Full Flow Flow = 99.85% of full flow Normal Depth Froude Number Frn = 0.56 subcritical Calculation of Critical Flow Condition Half Central Angle (0<Theta-c<3.14) Theta-c = 1.80 radians Critical flow area Ac = 3.15 sq ft Critical top width Tc = 2.44 ft Critical flow depth Yc = 1.53 ft Critical flow velocity Vc = 6.45 fps Critical Depth Froude Number Frc = 1.00 * Unexpected value for Manning's n CIRCULAR CONDUIT FLOW (Normal & Critical Depth Computation) Louden Ditch Pipe under Trilby Road Pipe under Trilby.xls, Pipe 11/6/2018, 11:03 AM Project: Pipe ID: Design Information (Input) Pipe Invert Slope So = 0.0079 ft/ft Pipe Manning's n-value n = 0.0220 * Pipe Diameter D = 24.00 inches Design discharge Q = 11.90 cfs Full-flow Capacity (Calculated) Full-flow area Af = 3.14 sq ft Full-flow wetted perimeter Pf = 6.28 ft Half Central Angle Theta = 3.14 radians Full-flow capacity Qf = 11.91 cfs Calculation of Normal Flow Condition Half Central Angle (0<Theta<3.14) Theta = 2.26 radians Flow area An = 2.75 sq ft Top width Tn = 1.54 ft Wetted perimeter Pn = 4.52 ft Flow depth Yn = 1.64 ft Flow velocity Vn = 4.32 fps Discharge Qn = 11.90 cfs Percent Full Flow Flow = 99.92% of full flow Normal Depth Froude Number Frn = 0.57 subcritical Calculation of Critical Flow Condition Half Central Angle (0<Theta-c<3.14) Theta-c = 1.81 radians Critical flow area Ac = 2.04 sq ft Critical top width Tc = 1.94 ft Critical flow depth Yc = 1.24 ft Critical flow velocity Vc = 5.82 fps Critical Depth Froude Number Frc = 1.00 * Unexpected value for Manning's n CIRCULAR CONDUIT FLOW (Normal & Critical Depth Computation) Louden Ditch Pipe under Skyway Drive Pipe under Skyway.xls, Pipe 11/6/2018, 11:04 AM 0.0 253.7 507.4 761.1 1014.8 1268.5 1522.2 1775.9 2029.6 2283.3 5038.85 5040.64 5042.44 5044.24 5046.04 5047.84 5049.64 5051.44 5053.24 5055.04 HGL EGL System Input Summary Rainfall Parameters Rainfall Return Period: 100 Rainfall Calculation Method: Formula One Hour Depth (in): 9.67 Rainfall Constant "A": 28.5 Rainfall Constant "B": 10 Rainfall Constant "C": 0.786 Rational Method Constraints Minimum Urban Runoff Coeff.: 0.20 Maximum Rural Overland Len. (ft): 500 Maximum Urban Overland Len. (ft): 300 Used UDFCD Tc. Maximum: Yes Sizer Constraints Minimum Sewer Size (in): 18.00 Maximum Depth to Rise Ratio: 0.90 Maximum Flow Velocity (fps): 18.0 Minimum Flow Velocity (fps): 2.0 Backwater Calculations: Tailwater Elevation (ft): 5040.60 Manhole Input Summary: Given Flow Sub Basin Information Element Name Ground Elevation (ft) Total Known Flow (cfs) Local Contribution (cfs) Drainage Area (Ac.) Runoff Coefficient 5yr Coefficient Overland Length (ft) Overland Slope (%) Gutter Length (ft) Gutter Velocity (fps) OUTFALL 1 5045.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 1 5044.94 28.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 2 5049.90 28.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 3 5051.90 28.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 4 SWR 4 - 1 5054.85 28.18 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Manhole Output Summary: Local Contribution Total Design Flow Element Name Overland Time (min) Gutter Time (min) Basin Tc (min) Intensity (in/hr) Local Contrib (cfs) Coeff. Area Intensity (in/hr) Manhole Tc (min) Peak Flow (cfs) Comment OUTFALL 1 0.00 0.00 0.00 0.00 0.00 0.63 44.89 0.06 28.20 MH 1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.20 MH 2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.20 MH 3 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.20 MH 4 SWR 4 - 1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.18 MH 5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.20 MH 6 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.20 MH 7 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.20 MH 8 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.20 MH 9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 28.20 Surface Water Present (Upstream) Sewer Input Summary: Elevation Loss Coefficients Given Dimensions Element Name Sewer Length (ft) Downstream Invert (ft) Slope (%) Upstream Invert (ft) Mannings n Bend Loss MH 4 SWR 4 - 1 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.18 405.00 MH 5 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.20 68.42 MH 6 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.20 403.00 MH 7 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.20 403.00 MH 8 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.20 403.00 MH 9 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.20 23.17 A Froude number of 0 indicates that pressured flow occurs (adverse slope or undersized pipe). If the sewer is not pressurized, full flow represents the maximum gravity flow in the sewer. If the sewer is pressurized, full flow represents the pressurized flow conditions. Sewer Sizing Summary: Existing Calculated Used Element Name Peak Flow (cfs) Cross Section Rise Span Rise Span Rise Span Area (ft^2) Comment MH 1 28.20 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 in 4.91 Existing height is smaller than the suggested height. Existing width is smaller than the suggested width. Exceeds max. Depth/Rise MH 2 28.20 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 in 4.91 Existing height is smaller than the suggested smaller than the suggested width. Exceeds max. Depth/Rise MH 5 28.20 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 in 4.91 Existing height is smaller than the suggested height. Existing width is smaller than the suggested width. Exceeds max. Depth/Rise MH 6 28.20 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 in 4.91 Existing height is smaller than the suggested height. Existing width is smaller than the suggested width. Exceeds max. Depth/Rise MH 7 28.20 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 Calculated diameter was determined by sewer hydraulic capacity rounded up to the nearest commercially available size. Sewer sizes should not decrease downstream. All hydraulics where calculated using the 'Used' parameters. Grade Line Summary: Tailwater Elevation (ft): 5040.60 Invert Elev. Downstream Manhole Losses HGL EGL Element Name Downstream (ft) Upstream (ft) Bend Loss (ft) Lateral Loss (ft) Downstream (ft) Upstream (ft) Downstream (ft) Friction Loss (ft) Upstream (ft) MH 1 5040.61 5040.65 0.00 0.00 5043.11 5043.16 5043.62 0.05 5043.67 MH 2 5040.45 5041.26 0.03 0.00 5043.18 5044.09 5043.69 0.91 5044.61 MH 3 5041.05 5041.86 0.03 0.00 5044.12 5045.03 5044.63 0.91 5045.54 MH 4 SWR 4 - 1 5041.67 5042.48 0.03 0.00 5045.06 5045.97 5045.57 0.91 5046.48 MH 5 5042.44 5042.58 0.03 0.00 5046.00 5046.15 5046.51 0.15 5046.66 MH 6 5042.37 5043.18 0.03 0.00 5046.18 5047.08 5046.69 0.91 5047.60 MH 7 5042.97 5043.78 0.03 0.00 5047.11 5048.02 5047.62 0.91 5048.53 MH 8 5043.57 5044.38 0.03 0.00 5048.04 5048.95 5048.56 0.91 5049.46 MH 9 5044.38 5044.43 0.03 0.00 5048.98 5049.03 5049.49 0.05 5049.54 Bend and Lateral losses only apply when there is an outgoing sewer. The system outfall, sewer #0, is not considered a sewer. Bend loss = Bend K * V_fi ^ 2/(2*g) Lateral loss = V_fo ^ 2/(2*g)- Junction Loss K * V_fi ^ 2/(2*g). Friction loss is always Upstream EGL - Downstream EGL. 0.0 253.7 507.4 761.1 1014.8 1268.5 1522.2 1775.9 2029.6 2283.3 5038.85 5040.64 5042.44 5044.24 5046.04 5047.84 5049.64 5051.44 5053.24 5055.04 HGL EGL System Input Summary Rainfall Parameters Rainfall Return Period: 100 Rainfall Calculation Method: Formula One Hour Depth (in): 9.67 Rainfall Constant "A": 28.5 Rainfall Constant "B": 10 Rainfall Constant "C": 0.786 Rational Method Constraints Minimum Urban Runoff Coeff.: 0.20 Maximum Rural Overland Len. (ft): 500 Maximum Urban Overland Len. (ft): 300 Used UDFCD Tc. Maximum: Yes Sizer Constraints Minimum Sewer Size (in): 18.00 Maximum Depth to Rise Ratio: 0.90 Maximum Flow Velocity (fps): 18.0 Minimum Flow Velocity (fps): 2.0 Backwater Calculations: Tailwater Elevation (ft): 5040.60 Manhole Input Summary: Given Flow Sub Basin Information Element Name Ground Elevation (ft) Total Known Flow (cfs) Local Contribution (cfs) Drainage Area (Ac.) Runoff Coefficient 5yr Coefficient Overland Length (ft) Overland Slope (%) Gutter Length (ft) Gutter Velocity (fps) OUTFALL 1 5045.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 1 5044.94 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 2 5049.90 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 3 5051.90 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 4 SWR 4 - 1 5054.85 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Manhole Output Summary: Local Contribution Total Design Flow Element Name Overland Time (min) Gutter Time (min) Basin Tc (min) Intensity (in/hr) Local Contrib (cfs) Coeff. Area Intensity (in/hr) Manhole Tc (min) Peak Flow (cfs) Comment OUTFALL 1 0.00 0.00 0.00 0.00 0.00 0.45 44.81 0.09 20.33 MH 1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 MH 2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 MH 3 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 MH 4 SWR 4 - 1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 MH 5 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 MH 6 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 MH 7 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 MH 8 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 MH 9 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.33 Sewer Input Summary: Elevation Loss Coefficients Given Dimensions Element Name Sewer Length (ft) Downstream Invert (ft) Slope (%) Upstream Invert (ft) Mannings n Bend Loss Lateral Loss Cross Section MH 5 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 MH 6 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 MH 7 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 MH 8 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 MH 9 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 A Froude number of 0 indicates that pressured flow occurs (adverse slope or undersized pipe). If the sewer is not pressurized, full flow represents the maximum gravity flow in the sewer. If the sewer is pressurized, full flow represents the pressurized flow conditions. Sewer Sizing Summary: Existing Calculated Used Element Name Peak Flow (cfs) Cross Section Rise Span Rise Span Rise Span Area (ft^2) Comment MH 1 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 MH 2 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 MH 3 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 MH 4 SWR 4 - 1 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 MH 5 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 MH 6 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 MH 7 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 MH 8 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 MH 9 20.33 CIRCULAR 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 30.00 in 4.91 Calculated diameter was determined by sewer hydraulic capacity rounded up to the nearest commercially available size. Sewer sizes should not decrease downstream. All hydraulics where calculated using the 'Used' parameters. Grade Line Summary: Tailwater Elevation (ft): 5040.60 Invert Elev. Downstream Manhole Losses HGL EGL Element Name Downstream (ft) Upstream (ft) Bend Loss (ft) Lateral Loss (ft) Downstream (ft) Upstream MH 6 5042.37 5043.18 0.01 0.00 5044.50 5044.90 5044.82 0.57 5045.40 MH 7 5042.97 5043.78 0.01 0.00 5045.08 5045.49 5045.41 0.58 5045.99 MH 8 5043.57 5044.38 0.01 0.00 5045.67 5046.09 5046.00 0.59 5046.59 MH 9 5044.38 5044.43 0.01 0.00 5046.12 5046.15 5046.60 0.04 5046.64 Bend and Lateral losses only apply when there is an outgoing sewer. The system outfall, sewer #0, is not considered a sewer. Bend loss = Bend K * V_fi ^ 2/(2*g) Lateral loss = V_fo ^ 2/(2*g)- Junction Loss K * V_fi ^ 2/(2*g). Friction loss is always Upstream EGL - Downstream EGL. (ft) Downstream (ft) Friction Loss (ft) Upstream (ft) MH 1 5040.61 5040.65 0.00 0.00 5042.14 5042.25 5042.78 0.05 5042.83 MH 2 5040.45 5041.26 0.01 0.00 5042.50 5042.94 5042.85 0.61 5043.46 MH 3 5041.05 5041.86 0.01 0.00 5043.14 5043.56 5043.47 0.59 5044.07 MH 4 SWR 4 - 1 5041.67 5042.48 0.01 0.00 5043.74 5044.17 5044.08 0.60 5044.69 MH 5 5042.44 5042.58 0.01 0.00 5044.26 5044.33 5044.70 0.11 5044.81 Rise (ft or in) Span (ft or in) MH 1 21.31 5040.61 0.2 5040.65 0.009 0.03 0.00 CIRCULAR 30.00 in 30.00 in MH 2 405.00 5040.45 0.2 5041.26 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 3 405.00 5041.05 0.2 5041.86 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 4 SWR 4 - 1 405.00 5041.67 0.2 5042.48 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 5 68.42 5042.44 0.2 5042.58 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 6 403.00 5042.37 0.2 5043.18 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 7 403.00 5042.97 0.2 5043.78 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 8 403.00 5043.57 0.2 5044.38 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 9 23.17 5044.38 0.2 5044.43 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in Sewer Flow Summary: Full Flow Capacity Critical Flow Normal Flow Element Name Flow (cfs) Velocity (fps) Depth (in) Velocity (fps) Depth (in) Velocity (fps) Froude Number Flow Condition Flow (cfs) Surcharged Length (ft) Comment MH 1 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 MH 2 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 MH 3 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 MH 4 SWR 4 - 1 26.57 5.41 18.37 6.45 19.66 5.96 0.88 Subcritical 20.33 0.00 MH 5 5055.30 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 6 5056.50 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 7 5049.75 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 8 5050.18 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 9 5048.93 20.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 in 4.91 Existing height is smaller than the suggested height. Existing width is smaller than the suggested width. Exceeds max. Depth/Rise MH 8 28.20 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 in 4.91 Existing height is smaller than the suggested height. Existing width is smaller than the suggested width. Exceeds max. Depth/Rise MH 9 28.20 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 in 4.91 Existing height is smaller than the suggested height. Existing width is smaller than the suggested width. Exceeds max. Depth/Rise height. Existing width is smaller than the suggested width. Exceeds max. Depth/Rise MH 3 28.20 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 in 4.91 Existing height is smaller than the suggested height. Existing width is smaller than the suggested width. Exceeds max. Depth/Rise MH 4 SWR 4 - 1 28.18 CIRCULAR 30.00 in 30.00 in 33.00 in 33.00 in 30.00 in 30.00 in 4.91 Existing height is smaller than the suggested height. Existing width is Lateral Loss Cross Section Rise (ft or in) Span (ft or in) MH 1 21.31 5040.61 0.2 5040.65 0.009 0.03 0.00 CIRCULAR 30.00 in 30.00 in MH 2 405.00 5040.45 0.2 5041.26 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 3 405.00 5041.05 0.2 5041.86 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 4 SWR 4 - 1 405.00 5041.67 0.2 5042.48 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 5 68.42 5042.44 0.2 5042.58 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 6 403.00 5042.37 0.2 5043.18 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 7 403.00 5042.97 0.2 5043.78 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 8 403.00 5043.57 0.2 5044.38 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in MH 9 23.17 5044.38 0.2 5044.43 0.009 0.05 0.00 CIRCULAR 30.00 in 30.00 in Sewer Flow Summary: Full Flow Capacity Critical Flow Normal Flow Element Name Flow (cfs) Velocity (fps) Depth (in) Velocity (fps) Depth (in) Velocity (fps) Froude Number Flow Condition Flow (cfs) Surcharged Length (ft) Comment MH 1 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.20 21.31 MH 2 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.20 405.00 MH 3 26.57 5.41 30.00 5.74 30.00 5.74 0.00 Pressurized 28.20 405.00 MH 5 5055.30 28.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 6 5056.50 28.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 7 5049.75 28.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 8 5050.18 28.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MH 9 5048.93 28.20 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00