HomeMy WebLinkAboutKYLE AVENUE SOLAR ARRAY - PDP / FDP - FDP180026 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANS6707 Winchester Cir, Boulder, CO 80301
888 Federal Blvd, Denver, CO 80204
www.NamasteSolar.com · 303.447.0300
CLIENT:
PROJECT:
SITE ADDRESS:
DRAWING SET ISSUE:
SHEET TITLE:
SHEET NUMBER:
DESCRIPTION:
REV. DATE NOTES
A B C D E F G H I J K
A B C D E F G H I J K
7
6
5
4
3
2
1
7
6
5
4
3
2
1
DRAWN BY: REVIEWED BY:
NOT FOR
CONSTRUCTION
A 2018/10/09 --
namaste solar electric, inc.
SINGLE-AXIS TRACKER PV PROJECT
6422 KYLE AVENUE, FORT COLLINS, CO
KYLE AVENUE SOLAR PROJECT
1.0
G001
COVER SHEET
MB HM
kyle avenue solar project
namaste solar electric, inc.
project development plan
Located on a tract of land in the Southwest quarter of Section 12, Township 6 North,
Range 69 West of the 6th Principal Meridian, in Larimer County, State of Colorado
VICINITY MAP
SITE AREA
SHEET LIST
SHEET TITLE
1 COVER SHEET
2-11 UTILITY PLANS (BY JVA)
12 FIRE TRUCK TURNING EXHIBIT (BY JVA)
13-15 LANDSCAPE PLANS (BY RUSSELL + MILLS)
16 TYPICAL DETAILS & ELEVATION DRAWING
17 FENCE DETAILS
18 RENDERINGS
19 ALTA SURVEY
PROJECT AREA
LEGAL DESCRIPTION
PER WARRANTY DEED, RECORDED AUGUST 12, 1986, RECEPTION NO. 86044443
CONSIDERING THE SOUTH LINE OF THE SW
1
4 OF SAID SECTION 12 AS BEARING N
89'46'40" W, AND WITH ALL BEARINGS CONTAINED HEREIN RELATIVE TO
THERETO; COMMENCING AT THE SOUTH QUARTER CORNER OF SAID SECTION 12;
THENCE N 00'25'50" E AND ALONG EAST LINE OF SAID SOUTHWEST QUARTER
504.09 FEET TO THE TRUE POINT OF BEGINNING; THENCE N 89'46'40" W, A
DISTANCE OF 308.48 FEET, THENCE N 00'25'50" E A DISTANCE OF 1235.58
FEET, THENCE S 89'46'40" E A DISTANCE OF 308.48 FEET, THENCE S00'25'50"
W A DISTANCE OF 1235.58 FEET TO THE TRUE POINT OF BEGINNING.
N
N
CONTACT INFORMATION
APPLICANT:
NAMASTE SOLAR ELECTRIC, INC.
6707 WINCHESTER CIRCLE, SUITE 700, BOULDER, CO 80301
CONTACT: HEATH MACKAY
PHONE: 303-447-0300, EXT. 235
ENGINEER:
JVA, INC.
213 LINDEN STREET, SUITE 200, FORT COLLINS, CO 80524
CONTACT: KAREN R. BRIGHAM
PHONE: 303-565-4892
SURVEYOR:
LAT40°, INC.
PROFESSIONAL LAND SURVEYORS
6250 W. 10th STREET, UNIT 2, GREELEY, CO 80634
CONTACT: KYLE RUTZ
PHONE: 970-515-5294
E. TRILBY ROAD
KYLE AVENUE
LAND USE TABLE
ITEM DETAIL
ZONING DESIGNATION URBAN ESTATE
DEVELOPMENT TYPE MEDIUM SCALE SOLAR ENERGY SYSTEM
PROJECT ACRES / SQ.FT. 5.90 ACRES / 257,058 SQ.FT.
MAX STRUCTURE HEIGHT 8.5' MAX
STANDARD NOTES
NAMASTE SOLAR ELECTRIC NOTES:
1. THE SPECIFIED SOLAR PV SYSTEM COMPONENTS ARE INTENDED TO EXHIBIT
REPRESENTATIVE INFORMATION ABOUT THE PROJECT. RACKING, MODULE, INVERTER & OTHER
COMPONENTS THAT ARE SIMILAR IN FORM AND FUNCTION MAY BE SUBSTITUTED FOR THE
COMPONENTS SPECIFIED IN THIS DOCUMENT. ADDITIONALLY, THE EXACT LOCATION OF THE
SOLAR PV ARRAYS AND ASSOCIATED ELECTRICAL EQUIPMENT MAY VARY SLIGHTLY FROM WHAT
IS EXHIBITED IN THIS DOCUMENT.
SITE PLAN NOTES:
1. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION
INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND
SERVICES, PROPOSED TOPOGRAPHY.
2. REFER TO THE ALTA SURVEY FOR EXACT LOCATIONS, AREAS AND DIMENSIONS
OF ALL EXISTING EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY
INFORMATION.
3. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL
PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY
THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS.
4. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN
ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS.
5. TBD - [IF APPLICABLE -- INCLUDE LANGUAGE FOR ANY MODIFICATIONS AND
CONDITIONS APPROVED WITH PDP/ODP].
6. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO
CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS,
DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS
STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF
COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST
CERTIFICATE OF OCCUPANCY.
7. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND
APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE
OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED
SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING
FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO
IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS
BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND
LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN
NECESSARY TO PROVIDE ADEQUATE VISIBILITY.
8. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED
AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE
ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS