Loading...
HomeMy WebLinkAboutFTC COLLINDALE, WTE (VERIZON) - BASIC DEVELOPMENT REVIEW - BDR180021 - SUBMITTAL DOCUMENTS - ROUND 2 - RESPONSE TO STAFF REVIEW COMMENTS16035 Table Mountain Pkwy Golden, CO 80403 P: 303-993-3293 / F: 303-993-3019 Re: FTC COLLINDALE Dated: 10/02/2018 Project: Cell site Rooftop Job Address: 4824 S. Lemay Ave., Ft. Collins, CO. 80525 To: Brandy Bethurem Harras Development Review Coordinator City of Fort Collins Community Development & Neighborhood Services 281 N. College Ave. Fort Collins, CO 80524 Hello Brandy, We are sending you this narrative pertaining to the Drawing Revisions you requested below: As Noted: RE: FTC Collindale, BDR180021, Round Number 1 Department: Planning Services Contact: Kai Kleer, 970-416-4284, kkleer@fcgov.com Topic: General Comment Number: 1 07/20/2018: The provided description of enclosure on page Z2 and material sample is appropriate, though, more detailed drawings are still needed. Drawings should include a close-up elevation view of the enclosure. Make sure to provide door and flashing details. [RESPONSE] Added larger scale elevations of enclosures. Door of Concealment Structure will be FRP and no flashing will be necessary Comment Number: 2 07/20/2018: To achieve co-location requirements is it possible to show an outline of where future equipment can be provided within the enclosure? If not, please explain. [RESPONSE] This design is such that any future carriers will need to work with the landlord for future lease space. Comment Number: 3 07/20/2018: Please provide details for the h-frame service light on page Z2, 3 Antenna Details. Please make sure the lights are 3,000K and full cutoff. [RESPONSE] Cut Sheets for the Emergency Light Fixtures are being provided. All lights will be located below screen walls and pointed down Comment Number: 4 07/20/2018: Please step back the enclosure located on top of the penthouse from edge of the building add flashing as described in comment 1. [RESPONSE] Done, new Concealment walls have been held back and located over bearing walls below, new band has been added at tome and will match the color of the existing penthouse gutters/flashing Department: Environmental Planning Contact: Stephanie Blochowiak, 970-416-4290, sblochowiak@fcgov.com Topic: General Comment Number: 1 07/23/2018: No comments. 16035 Table Mountain Pkwy Golden, CO 80403 P: 303-993-3293 / F: 303-993-3019 Department: PFA Contact: Jim Lynxwiler, 970-416-2869, jlynxwiler@poudre-fire.org Topic: General Comment Number: 1 07/21/2018: Poudre Fire Authority has no further comment for this communication site. Department: Stormwater Engineering Contact: Dan Mogen, 970-224-6192, dmogen@fcgov.com Topic: General Comment Number: 1 07/09/2018: The submitted plans do not depict existing utilities including water, wastewater, and stormwater. It appears the proposed bores are in the vicinity of existing water and will cross existing stormwater pipes in multiple locations; please review "Columbine East Long-Term Care" plans that show utilities for this property. Please locate and show these existing utilities on the plans, provide adequate separation, and show crossing conflicts and how they will be addressed. [RESPONSE] Drawings have been updated to include existing Water / Stormwater pipes in the area of the new Fiber Service Run, and the crossings identifed. Notes have been added for Contractor to locate existing pipe and verify depth for new borings. Department: Water-Wastewater Engineering Contact: Dan Mogen, 970-224-6192, dmogen@fcgov.com Topic: General Comment Number: 1 07/09/2018: The submitted plans do not depict existing utilities including water, wastewater, and stormwater. It appears the proposed bores are in the vicinity of existing water and will cross existing stormwater pipes in multiple locations; please review "Columbine East Long-Term Care" plans that show utilities for this property. Please locate and show these existing utilities on the plans, provide adequate separation, and show crossing conflicts and how they will be addressed. [RESPONSE] Drawings have been updated to include existing Water / Stormwater pipes in the area of the new Fiber Service Run, and the crossings identifed. Notes have been added for Contractor to locate existing pipe and verify depth for new borings. Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: General Comment Number: 1 07/23/2018: Please revise the legal description as marked. See redlines. [RESPONSE] Done Comment Number: 07/23/2018: All plan sheets must be 24"x36". [RESPONSE] Done Comment Number: 07/23/2018: Sheet PH2 is labeled as PH1 [RESPONSE] Done Brad Bryant A & E PROJECT MANAGER CENTERLINE SOLUTIONS 16035 Table Mountain Parkway Golden, CO 80403 Phone: 303.993.3293 x1383 Mobile: 720.284.8628