Loading...
HomeMy WebLinkAboutHOFFMAN MILL FUEL SITE - MINOR AMENDMENT - MA180043 / BDR180015 - SUBMITTAL DOCUMENTS - ROUND 2 - DRAINAGE RELATED DOCUMENT1218 W. ASH, STE. A, WINDSOR, COLORADO 80550 TEL. 970.674.3300 – FAX 970.674.3303 September 26, 2018 Ms. Heather McDowell, P.E. Fort Collins Utilities – Stormwater 700 Wood Street Fort Collins, CO 80522 Re: Hoffman Mill Fueling Site Final Storm Drainage Letter Dear Heather, Please accept the following letter describing the storm drainage intent demonstrating the proposed site improvement’s ability to comply with the City’s stormwater requirements. INTRODUCTION The Hoffman Mill Fueling Site project proposes to construct a gas and diesel fueling station on the Hoffman Mill recycling/crushing operations site. The site is located north of Hoffman Mill Road, east of Lemay Avenue and south of the Cache La Poudre River and is only a portion of the recycling/crushing operations site. The fueling site is proposed to be located south of the existing building, closest to Hoffman Mill Road. A vicinity map is attached for reference. EXISTING CONDITIONS The project site is located within the Cache La Poudre drainage basin. The existing site consists of miscellaneous material storage and is generally undeveloped. The site generally slopes from the northwest to the southeast at approximately 1.0% grade. All existing material storage and miscellaneous site improvements will be removed from the site to accommodate the new construction. We are not aware of any site-specific drainage studies for this site. The project is not located within a FEMA mapped 100-yr floodplain and is not within a defined City of Fort Collins floodplain. PROPOSED DEVELOPMENT The prosed redevelopment improvements will consist of a constructing a 24 ft wide looping drive lane and fuel storage/dispensing equipment. A detention pond and sand filter are proposed to satisfy the storm drainage detention and Low Impact Development (LID) requirements. A long swale is proposed to be constructed along the north side of Hoffman Mill Road and will provide a gravity outfall for the site’s storm drainage runoff. The project is planned to be constructed in a single phase. Hoffman Mill Fueling Site Final Storm Drainage Letter September 26, 2018 Page 2 of 4 The proposed improvements are included in a single drainage basin with one offsite basin drainage to and being conveyed through the proposed improvements. These basins consist of: Basin D1 consists of the fueling site and is approximately 0.59 acres and 44.8% impervious. The detention and water quality facilities are located within this basin and outfall to the proposed swale. Basin OS1 consists of the are north and west of the proposed site that drains to Basin D1. The basin is approximately 3.05 acres and is 12.4% impervious. The runoff from this basin will be routed through the detention pond. An outfall swale is proposed along the north side of Hoffman Mill Road and will discharge to the existing water quality structure, similar to as is has historically. Due to grade limitations, the swale is designed with a 0.5% slope. This slope will help sediment settle from the adjacent crushing operations areas and provide a gravity outfall for the fuel site. All calculations and exhibits are attached for reference. Detention Pond The proposed detention pond detains the developed runoff to the historic 2-yr runoff rate. The historic 2- yr runoff rate is 0.50 cfs and combined with the offsite flows routed through the pond of 7.2 cfs, provides a release rate of 7.70 cfs. The required 100-yr detention volume is 2,788 cu-ft with a water surface elevation of 4946.90 ft. Majority of the site improvement’s runoff surface drains to the sand filter and spills into the detention pond when runoff rates exceed the capacity of the sand filter. The water quality capture volume for the sand filter is 283 cu-ft. Combined with the 100-yr detention volume, the required pond volume is 3,071 cu-ft. The water quality capture volume water surface elevation is controlled by the spillway with an elevation of 4947.70 ft. The sand filter is intended to provide water quality enhancement and to satisfy the Low Impact Development (LID) requirements. All calculations and exhibits are attached for reference. LOW IMPACT DEVELOPMENT TECHNIQUES In reference to the code requirements for implementation of Low Impact Development (LID) techniques, the use of sand filter is proposed to satisfy these requirements. The sand filter will slow runoff, promote a reduction of runoff through infiltration, and will also capture sediment prior to discharging through the perforated underdrain. Below is a description of the 4 step process for selecting structural BMPs: Urban Drainage and Flood Control District (UDFCD) recommends a Four Step Process for receiving water protection that focuses on reducing runoff volumes, treating the water quality capture volume (WQCV), stabilizing drainageways and implementing long-term source controls. The Four Step Process applies to the management of smaller, frequently occurring events. Step 1: Employ Runoff Reduction Practices To reduce runoff peaks, volumes, and pollutant loads from urbanizing areas, implement Low Impact Development (LID) strategies, including Minimizing Directly Connected Impervious Areas (MDCIA). Hoffman Mill Fueling Site Final Storm Drainage Letter September 26, 2018 Page 3 of 4 The sand filter will slow runoff, promote infiltration, and filter runoff prior to being released into the adjacent storm drain system. Step 2: Implement BMPs that Provide a Water Quality Capture Volume with Slow Release The sand filter will provide a slow release by infiltration through the sand media. Step 3: Stabilize Drainageways Natural Drainageways are subject to bed and bank erosion due to increases in frequency, duration, rate and volume of runoff during and following development. The site will ultimately drain to an existing swale that is well vegetated and addition bank stabilization is unnecessary with this project. Step 4: Implement Site Specific and Other Source Control BMPs Proactively controlling pollutants at their source by preventing pollution rather than removing contaminants once they have entered the stormwater system or receiving waters is important when protecting storm systems and receiving waters. This can be accomplished through site specific needs such as construction site runoff control, post-construction runoff control and pollution prevention / good housekeeping. It will be the responsibility of the contractor to develop a procedural best management practice for the site. A spill control structure is proposed with this project. Runoff from the dispensing area and fuel storage area will drain to a modified Type R inlet. The inlet is modified to provide a baffle to capture spilt fuel. It also has a valve to control the flow leaving the inlet during a spill event. It will the operators’ responsibility to frequently observe structure and removed any accumulated fuel and also close the outlet valve during a spill event. All calculations are attached for reference. EROSION CONTROL Erosion and sedimentation will be controlled on-site by use of sediment control logs, inlet protection, a gravel construction entrance, seeding, mulch, and turf. The measures are designed to limit the overall sediment yield increase due to construction as required by the City of Fort Collins. During overlot and final grading the soil will be roughened and furrowed perpendicular to the prevailing winds. During the performance of the work required by these specifications or any operations appurtenant thereto, whether on right-of-way provided by the City or elsewhere, the contractor shall furnish all labor, equipment, materials, and means required. The Contractor shall carry out proper efficient measures wherever and as necessary to reduce dust nuisance, and to prevent dust nuisance that has originated from his operations from damaging crops, orchards, cultivated fields, and dwellings, or causing naissance to persons. The Contractor will be held liable for any damage resulting from dust originating from his operations under these specifications on right-of-way or elsewhere. It is unlawful to track or cause to be tracked mud or other debris onto city streets or rights-of-way. Wherever construction vehicles access routes or intersect paved public roads, previsions must be made to minimize the transport of sediment by runoff or vehicles tracking onto the paved surface. Stabilized Hoffman Mill Fueling Site Final Storm Drainage Letter September 26, 2018 Page 4 of 4 construction entrances are required with base material consisting of 6” coarse aggregate. The contractor will be responsible for clearing mud tracked onto city streets on a daily basis. All temporary and permanent erosion and sediment control practices must be maintained and repaired as needed to assure continued performance of their intended function. Silt fence and sediment control logs will require periodic replacement. Maintenance is the responsibility of the contractor. All disturbed areas must be seeded and mulched within 30 days of project start. Vegetation shall not be considered established until a ground cover is achieved which is demonstrated to be mature enough to control soil erosion to the satisfaction of the City Inspector and to survive severe weather condition. Thank you in advance for your time and if you have any questions or comments please contact me at (970) 347-8917. Sincerely, Jason T. Claeys, P.E., LEED AP Interwest Consulting Group Attachments SITE Vicinity Map Scale: 1" = 1000' PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK #17-92 300 FEET SOUTH OF THE SOUTHWEST CORNER OF EAST DRAKE RD AND TIMBERLINE RD, IN THE TOP OF AN IRRIGATION STRUCTURE ELEV= 4938.70 CITY OF FORT COLLINS BENCHMARK #8-02 ON THE SOUTHEAST CORNER OF THE INTERSECTION OF LEMAY AVE AND MULBERRY ST, IN THE CURB, ON THE SOUTHEAST SIDE OF A TRIANGULAR ISLAND THAT CONTAINS THE TRAFFIC SIGNAL. ELEV= 4939.27 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS MAY HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS IF NGVD29 UNADJUSTED IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATIONS SHOULD BE USED: NGVD UNADJUSTED = (NAVD88) - 3.19 HOFFMAN MILL ROAD 1218 W. Ash, Suite A Windsor , Colorado 80550 Phone: (970) 674-3300 Fax: (970) 674-3303 I N T E R W E S T C O N S U L T I N G G R O U P PREPARED FOR PROJ. NO. DATE: SCALE (H): SCALE (V): CHECKED BY: DESIGNED BY: PROJECT NAME HOFFMAN MILL FUELING SITE HISTORIC DRAINAGE BASINS 06/06/18 1" = 60' N/A JTC JTC 1344-095-00 1 of 1 BASIN COEFFICIENT (100-YR) BASIN DESIGNATION BASIN AREA DESIGN POINT DRAINAGE FLOW ARROW DRAINAGE BASIN BOUNDARY DRAINAGE BASIN FLOW PATH LEGEND SCALE 1" = 0 60' 30 60 Design Engineer: Design Firm: Project Number: Date: % Impervious Runoff Coefficient C Return Period Frequency Adjustment Factor (Cf) 100% 0.95 2-year to 10-year 1.00 90% 0.95 100-year 1.25 90% 0.95 40% 0.50 0% 0.25 C2 to C10 C100 OS1 133,035 3.054 0 8,330 9,935 0 114,770 12.4% 0.35 0.43 H1 25,833 0.593 0 2,480 3,038 0 20,315 19.2% 0.40 0.50 Apavers (sq feet) Alawn (sq feet) Weighted % Impervious COMPOSITE Hoffman Mill Fuel Site EXISTING IMPERVIOUS AREA CALCULATION Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised January 2016) DESIGN CRITERIA: BASINS: % Impervious values from Table RO-3 in the Urban Storm Drainage Criteria Manual Sub-basin Designation Atotal (sq feet) Atotal (acres) Apaved (sq feet) Aroof (sq feet) Awalk/RAP (sq feet) Lawns (Heavy, 2-7% Slope) J.Claeys Interwest Consulting Group 1344-095-00 June 6, 2018 Runoff Coefficients and Frequency Adjustment Factors for City of Fort Collins - Storm Water Criteria Manual Land Use Paved Roof Walks/RAP Design Engineer: Design Firm: Project Number: Date: EQUATIONS: -Equation 6-2 -Equation 6-4 -Urbanized Check Equation 6-5 - CoFC Overland Flow CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins Time of Concentration (2-yr to 10-yr) Type of Travel Surface Cv OS1 OS1 12.4% 0.35 3.054 300 0.0157 21.02 234 0.0120 Paved Areas 20 2.19 1.78 22.80 0.0141 21.16 21.16 H1 H1 19.2% 0.40 0.593 88 0.0291 8.63 154 0.0093 Paved Areas 20 1.93 1.33 9.96 0.0165 17.01 9.96 June 6, 2018 Hoffman Mill Fuel Site HISTORIC TIME OF CONCENTRATION J.Claeys Interwest Consulting Group 1344-095-00 LENGTH (ft) DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Overland Flow Equations for City of Fort Collins - Storm Water Criteria Manual SUB-BASIN DATA INITIAL/OVERLAND TIME (ti ) TRAVEL TIME (tt ) tc =ti +tt (min) Urban Check Final tc (min) DESIGN POINT Sub-basin % Impervious C2-10 AREA (acres) tt (min) OVERALL SLOPE (ft/ft) tc (min) SLOPE (ft/ft) ti (min) Design Engineer: Design Firm: Project Number: Date: EQUATIONS: -Equation 6-2 -Equation 6-4 -Urbanized Check Equation 6-5 - CoFC Overland Flow CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins Time of Concentration (100-yr) Type of Travel Surface Cv OS1 OS1 12.4% 0.43 3.054 300 0.0157 18.61 234 0.0120 Paved Areas 20 2.19 1.78 20.39 0.0141 21.16 20.39 H1 H1 19.2% 0.50 0.593 88 0.0291 7.40 154 0.0093 Paved Areas 20 1.93 1.33 8.73 0.0165 17.01 8.73 June 6, 2018 Hoffman Mill Fuel Site HISTORIC TIME OF CONCENTRATION J.Claeys Interwest Consulting Group 1344-095-00 LENGTH (ft) DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Overland Flow Equations for City of Fort Collins - Storm Water Criteria Manual SUB-BASIN DATA INITIAL/OVERLAND TIME (ti ) TRAVEL TIME (tt ) tc =ti +tt (min) Urban Check Final tc (min) DESIGN POINT Sub-basin % Impervious C100 AREA (acres) tt (min) OVERALL SLOPE (ft/ft) tc (min) SLOPE (ft/ft) ti (min) Design Engineer: Design Firm: Project Number: Date: EQUATIONS: I = rainfall intensity (in/hr) Q n = n -yr peak discharge (cfs) P 1 = one-hour point rainfall depth (in) C n = n -yr runoff coefficient t c = time of concentration (min) I n = n -yr rainfall intensity (in/hr) P 1-2yr = 0.82 in A n = Basin drainage area (ac) P 1-10yr = 1.40 in P 1-100yr = 2.86 in BASIN SUMMARY: tc (min) Runoff Coeff (C2) C(A) (acres) Intensity (in/hr) Q (ft3/s) tc (min) Runoff Coeff. (C10) C(A) (acres) Intensity (in/hr) Q (ft3/s) tc (min) Runoff Coeff. (C100) C(A) (acres) Intensity (in/hr) Q (ft3/s) OS1 OS1 3.054 21.16 0.35 1.06 1.56 1.65 21.16 0.35 1.06 2.67 2.82 20.39 0.43 1.32 5.45 7.20 H1 H1 0.593 9.96 0.40 0.24 2.22 0.53 9.96 0.40 0.24 3.79 0.90 8.73 0.50 0.30 7.74 2.29 June 6, 2018 Hoffman Mill Fuel Site HISTORIC PEAK RUNOFF J.Claeys Interwest Consulting Group 1344-095-00 DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) Design Point Sub-basin Area (acres) 2-yr Peak Runoff 10-yr Peak Runoff 100-yr Peak Runoff Q n = C n I n A n 0.786651) 1 ( 10 ) 28 . 5 t c P I + = 1344-095-00 Rational Calcs (FC).xlsx Page 4 of 4 Interwest Consulting Group Design Engineer: Design Firm: Project Number: Date: % Impervious Runoff Coefficient C Return Period Frequency Adjustment Factor (Cf) 100% 0.95 2-year to 10-year 1.00 90% 0.95 100-year 1.25 90% 0.95 40% 0.50 0% 0.25 C2 to C10 C100 D1 25,836 0.59 0 2,481 10,384 0 12,971 44.8% 0.60 0.75 Hoffman Mill Fuel Site DEVELOPED IMPERVIOUS AREA CALCULATION DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised January 2016) BASINS: % Impervious values from Table RO-3 in the Urban Storm Drainage Criteria Manual J.Claeys Interwest Consulting Group 1344-095-00 June 6, 2018 Land Use Paved Roof Walks Runoff Coefficients and Frequency Adjustment Factors for City of Fort Collins - Storm Water Criteria Manual Gravel/Pavers Lawns (Heavy, 2-7% Slope) Sub-basin Designation Atotal (sq feet) Atotal (acres) Weighted % Impervious Apaved COMPOSITE (sq feet) Aroof (sq feet) Awalk (sq feet) Agravel/pavers (sq feet) Alawn (sq feet) 1344-095-00 Rational Calcs (FC).xlsx Page 1 of 4 Interwest Consulting Group Design Engineer: Design Firm: Project Number: Date: EQUATIONS: -Equation 6-2 -Equation 6-4 -Urbanized Check Equation 6-5 - CoFC Overland Flow CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins Time of Concentration (2-yr to 10-yr) Type of Travel Surface Cv D1 D1 44.8% 0.60 0.593 156 0.0072 13.08 150 0.0229 Paved Areas 20 3.03 0.83 13.90 0.0149 13.11 13.11 June 6, 2018 Hoffman Mill Fuel Site DEVELOPED TIME OF CONCENTRATION J.Claeys Interwest Consulting Group 1344-095-00 LENGTH (ft) DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Overland Flow Equations for City of Fort Collins - Storm Water Criteria Manual SUB-BASIN DATA INITIAL/OVERLAND TIME (ti ) TRAVEL TIME (tt ) tc =ti +tt (min) Urban Check Final tc (min) DESIGN POINT Sub-basin % Impervious C2-10 AREA (acres) tt (min) OVERALL SLOPE (ft/ft) tc (min) SLOPE (ft/ft) ti (min) LENGTH Design Engineer: Design Firm: Project Number: Date: EQUATIONS: -Equation 6-2 -Equation 6-4 -Urbanized Check Equation 6-5 - CoFC Overland Flow CONSTRAINTS: 300 ft - Overland flow shall not exceed for developed condition 500 ft - Overland flow shall not exceed for undeveloped condition Final t c = minimum of t i + t t and urbanized basin check recommended minimum t c = 5 min for urbanized basins Time of Concentration (100-yr) Type of Travel Surface Cv D1 D1 44.8% 0.75 0.593 156 0.0072 9.18 150 0.0229 Grassed Waterway 15 2.27 1.10 10.28 0.0149 13.11 10.28 June 6, 2018 Hoffman Mill Fuel Site DEVELOPED TIME OF CONCENTRATION J.Claeys Interwest Consulting Group 1344-095-00 LENGTH (ft) DESIGN CRITERIA: Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised January 2016) Overland Flow Equations for City of Fort Collins - Storm Water Criteria Manual SUB-BASIN DATA INITIAL/OVERLAND TIME (ti ) TRAVEL TIME (tt ) tc =ti +tt (min) Urban Check Final tc (min) DESIGN POINT Sub-basin % Impervious C100 AREA (acres) tt (min) OVERALL SLOPE (ft/ft) tc (min) SLOPE (ft/ft) ti (min) LENGTH Design Engineer: Design Firm: Project Number: Date: EQUATIONS: I = rainfall intensity (in/hr) Q n = n -yr peak discharge (cfs) P 1 = one-hour point rainfall depth (in) C n = n -yr runoff coefficient t c = time of concentration (min) I n = n -yr rainfall intensity (in/hr) P 1-2yr = 0.82 in A n = Basin drainage area (ac) P 1-10yr = 1.40 in P 1-100yr = 2.86 in BASIN SUMMARY: tc (min) Runoff Coeff (C2-10) C(A) (acres) Intensity (in/hr) Q (ft3/s) tc (min) Runoff Coeff (C2-10) C(A) (acres) Intensity (in/hr) Q (ft3/s) tc (min) Runoff Coeff. (C100) C(A) (acres) Intensity (in/hr) Q (ft3/s) D1 D1 0.593 13.11 0.60 0.36 1.98 0.70 13.11 0.60 0.36 3.37 1.20 10.28 0.75 0.44 7.64 3.39 10-yr Peak Runoff 100-yr Peak Runoff Hoffman Mill Fuel Site DEVELOPED PEAK RUNOFF Urban Storm Drainage Criteria Manual by Urban Drainage and Flood Control District, June 2001 (Revised August 2006) DESIGN CRITERIA: Design Point Sub-basin Area (acres) J.Claeys Interwest Consulting Group 1344-095-00 June 6, 2018 2-yr Peak Runoff Q n = C n I n A n 0.786651) 1 ( 10 ) 28 . 5 t c P I + = 1344-095-00 Rational Calcs (FC).xlsx Page 4 of 4 Interwest Consulting Group Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Detention Volume Calculation 0.60 1.25 0.75 ft3 acre-ft 0.59 acres 2,788 0.064 0.50 cfs Time (min) 100-yr Intensity (I , in/hr) Q100 (cfs) Accumulative Runoff Volume (ft3) Release Volume (ft3) Detained Volume (ft3) Detained Volume (acre-ft) 0 0.00 0.00 0.00 0.00 0.00 0.0000 5 9.95 4.40 1,320.86 150.00 1,170.86 0.0269 10 7.72 3.42 2,049.66 300.00 1,749.66 0.0402 15 6.52 2.89 2,596.59 450.00 2,146.59 0.0493 20 5.60 2.48 2,973.60 600.00 2,373.60 0.0545 25 4.98 2.20 3,305.48 750.00 2,555.48 0.0587 30 4.52 2.00 3,600.18 900.00 2,700.18 0.0620 35 4.08 1.81 3,791.34 1,050.00 2,741.34 0.0629 40 3.74 1.65 3,971.88 1,200.00 2,771.88 0.0636 45 3.46 1.53 4,133.84 1,350.00 2,783.84 0.0639 50 3.23 1.43 4,287.83 1,500.00 2,787.83 0.0640 55 3.03 1.34 4,424.56 1,650.00 2,774.56 0.0637 60 2.86 1.27 4,555.98 1,800.00 2,755.98 0.0633 65 2.72 1.20 4,694.04 1,950.00 2,744.04 0.0630 70 2.59 1.15 4,813.52 2,100.00 2,713.52 0.0623 75 2.48 1.10 4,938.30 2,250.00 2,688.30 0.0617 80 2.38 1.05 5,055.12 2,400.00 2,655.12 0.0610 85 2.29 1.01 5,167.96 2,550.00 2,617.96 0.0601 90 2.21 0.98 5,280.80 2,700.00 2,580.80 0.0592 95 2.13 0.94 5,372.39 2,850.00 2,522.39 0.0579 100 2.06 0.91 5,469.30 3,000.00 2,469.30 0.0567 105 2.00 0.89 5,575.50 3,150.00 2,425.50 0.0557 110 1.94 0.86 5,665.77 3,300.00 2,365.77 0.0543 115 1.89 0.84 5,770.64 3,450.00 2,320.64 0.0533 120 1.84 0.81 5,862.24 3,600.00 2,262.24 0.0519 125 1.79 0.79 5,940.56 3,750.00 2,190.56 0.0503 130 1.75 0.77 6,040.13 3,900.00 2,140.13 0.0491 135 1.71 0.76 6,129.07 4,050.00 2,079.07 0.0477 140 1.67 0.74 6,207.39 4,200.00 2,007.39 0.0461 145 1.63 0.72 6,275.09 4,350.00 1,925.09 0.0442 Sheet 1 of 2 Designer: Company: Date: Project: Location: 1. Basin Storage Volume A) Effective Imperviousness of Tributary Area, Ia Ia = 100.0 % (100% if all paved and roofed areas upstream of sand filter) B) Tributary Area's Imperviousness Ratio (i = Ia/100) i = 1.000 C) Water Quality Capture Volume (WQCV) Based on 12-hour Drain Time WQCV = 0.40 watershed inches WQCV= 0.8 * (0.91* i3 - 1.19 * i2 + 0.78 * i) D) Contributing Watershed Area (including sand filter area) Area = 8,500 sq ft E) Water Quality Capture Volume (WQCV) Design Volume VWQCV = 283 cu ft VWQCV = WQCV / 12 * Area F) For Watersheds Outside of the Denver Region, Depth of d6 = 0.43 in Average Runoff Producing Storm G) For Watersheds Outside of the Denver Region, VWQCV OTHER = 283 cu ft Water Quality Capture Volume (WQCV) Design Volume H) User Input of Water Quality Capture Volume (WQCV) Design Volume VWQCV USER = cu ft (Only if a different WQCV Design Volume is desired) 2. Basin Geometry A) WQCV Depth DWQCV = 0.75 ft B) Sand Filter Side Slopes (Horizontal distance per unit vertical, Z = 4.00 ft / ft 4:1 or flatter preferred). Use "0" if sand filter has vertical walls. C) Minimum Filter Area (Flat Surface Area) AMin = 106 sq ft D) Actual Filter Area AActual = 219 sq ft E) Volume Provided VT = cu ft 3. Filter Material 4. Underdrain System A) Are underdrains provided? B) Underdrain system orifice diameter for 12 hour drain time i) Distance From Lowest Elevation of the Storage y = ft Volume to the Center of the Orifice ii) Volume to Drain in 12 Hours Vol12 = N/A cu ft iii) Orifice Diameter, 3/8" Minimum DO = in Hoffman Mill Fueling Site Design Procedure Form: Sand Filter (SF) J.Claeys Interwest Consulting Group June 6, 2018 UD-BMP (Version 3.06, November 2016) Choose One Choose One 18" CDOT Class B or C Filter Material Other (Explain): YES NO UD-BMP_v3.06.xlsm, SF 6/5/2018, 5:10 PM Hoffman Mill Fueling Site Critical Pond Elevations Design Engineer: Design Firm: Project Number: Date: DESIGN CRITERIA Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, June 2001 (Revised April 2008) Volume obtained utilizing 2018 AutoCAD Civil3D Storage Summary 4947.00 ft 283 cu-ft 290 cu-ft 4947.70 ft 2,788 cu-ft 3,071 cu-ft 4944.56 ft 3,164 cu-ft 4946.90 ft Require 100-yr Detention Volume Total Detention Volume Provided 100-yr WSE J.Claeys Interwest Consulting Group 1344-095-00 September 25, 2018 Pond Invert Elevation Sand Filter Invert Elevation Required Water Qualtiy Capture Volume (WQCV) WQCV Provided WQCV Water Surface Elevation (WSE) Combined Required 100-yr Detention & WQCV 1344-095-00 PondCalcs.xls - Pond Stage Storage Page 1 of 3 Interwest Consulting Group Hoffman Mill Fueling Site Emergency Overflow Spillway Calculations Design Engineer: Design Firm: Project Number: Date: Broad-Crested Weir Equation-Trapezoidal Shape where: Q = Discharge (cfs) C = Weir Coeffecient L = Weir Length (ft) H = Average Weir Head (ft) H:V =Side Slope Calculations Knowns: 4.00 0.25 ft 2.6 4947.70 ft 3.39 cfs 9.43 ft 10 ft 0.00 ft 0.25 ft 4947.95 ft Side Slopes (H:V) Desired Spillway Head Weir Coefficient Spillway Elevation J.Claeys Interwest Consulting Group 1344-095-00 September 25, 2018 Top of Berm Elevation 100-yr Pond Inflow Calculated Spillway Length Use Spillway Length Total Spillway Depth Spillway Freeboard 2 5 2 3 H V H QCLH C       = + 1344-095-00 PondCalcs.xls - Spillway Page 2 of 3 Interwest Consulting Group Hoffman Mill Fueling Site Circular Orifice Plate Sizing Design Engineer: Design Firm: Project Number: Date: Orifice Equation where: C = Orifice Discharge Coefficient A o = Orifice Area (ft 2 ) g = Gravity (32.2 ft/s 2 ) Dh = Difference in Elevation Head (ft) D o = Orifice Diameter (in) Calculations 100-yr Orifice Sizing 100-yr Orifice Rating Table Knowns: 100-yr Release Rate 7.7 cfs 100-yr WSEL 4946.90 ft 4944.56 0.00 4945.00 0.00 Pond Outlet Invert 4944.56 ft 4946.00 5.36 4946.90 7.70 Discharge Coefficient 0.65 Tailwater Elevation 4944.94 ft Orifice Diameter 14 5/16 in Orifice Area 1.118 ft 2 Centroid Elevation 4945.16 ft Actual Release Rate 7.70 cfs J.Claeys Interwest Consulting Group 1344-095-00 September 25, 2018 Elevation (ft) Discharge (cfs) C g h Q QCA o g h A o ∆ = ∆ ⇒ = 2 2 π o o A D = 576 1344-095-00 PondCalcs.xls - Outlet Orifice Plate Sizing Page 3 of 3 Interwest Consulting Group Culvert Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Tuesday, Jun 5 2018 Hoffman Mill Fuel Station - Culvert Sizing Invert Elev Dn (ft) = 100.00 Pipe Length (ft) = 32.00 Slope (%) = 0.50 Invert Elev Up (ft) = 100.16 Rise (in) = 18.0 Shape = Circular Span (in) = 18.0 No. Barrels = 1 n-Value = 0.012 Culvert Type = Circular Concrete Culvert Entrance = Square edge w/headwall (C) Coeff. K,M,c,Y,k = 0.0098, 2, 0.0398, 0.67, 0.5 Embankment Top Elevation (ft) = 102.50 Top Width (ft) = 24.00 Crest Width (ft) = 20.00 Calculations Qmin (cfs) = 0.00 Qmax (cfs) = 10.00 Tailwater Elev (ft) = (dc+D)/2 Highlighted Qtotal (cfs) = 8.00 Qpipe (cfs) = 8.00 Qovertop (cfs) = 0.00 Veloc Dn (ft/s) = 4.92 Veloc Up (ft/s) = 5.79 HGL Dn (ft) = 101.30 HGL Up (ft) = 101.25 Hw Elev (ft) = 101.98 Hw/D (ft) = 1.21 Flow Regime = Inlet Control Channel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 3D® by Autodesk, Inc. Tuesday, Jun 5 2018 Hoffman Mill Fuel Site - Ditch Capacity Triangular Side Slopes (z:1) = 4.00, 4.00 Total Depth (ft) = 2.00 Invert Elev (ft) = 100.00 Slope (%) = 0.50 N-Value = 0.030 Calculations Compute by: Known Q Known Q (cfs) = 8.00 Highlighted Depth (ft) = 0.98 Q (cfs) = 8.000 Area (sqft) = 3.84 Velocity (ft/s) = 2.08 Wetted Perim (ft) = 8.08 Crit Depth, Yc (ft) = 0.76 Top Width (ft) = 7.84 EGL (ft) = 1.05 0 2 4 6 8 10 12 14 16 18 20 Elev (ft) Depth (ft) Section 99.50 -0.50 100.00 0.00 100.50 0.50 101.00 1.00 101.50 1.50 102.00 2.00 102.50 2.50 103.00 3.00 Reach (ft) 150 1.60 0.71 6,372.00 4,500.00 1,872.00 0.0430 155 1.57 0.69 6,460.94 4,650.00 1,810.94 0.0416 160 1.54 0.68 6,541.92 4,800.00 1,741.92 0.0400 165 1.51 0.67 6,614.93 4,950.00 1,664.93 0.0382 170 1.48 0.65 6,679.98 5,100.00 1,579.98 0.0363 175 1.45 0.64 6,737.06 5,250.00 1,487.06 0.0341 180 1.42 0.63 6,786.18 5,400.00 1,386.18 0.0318 185 1.40 0.62 6,876.45 5,550.00 1,326.45 0.0305 190 1.38 0.61 6,961.41 5,700.00 1,261.41 0.0290 195 1.36 0.60 7,041.06 5,850.00 1,191.06 0.0273 200 1.34 0.59 7,115.40 6,000.00 1,115.40 0.0256 205 1.32 0.58 7,184.43 6,150.00 1,034.43 0.0237 210 1.30 0.58 7,248.15 6,300.00 948.15 0.0218 215 1.28 0.57 7,306.56 6,450.00 856.56 0.0197 220 1.26 0.56 7,359.66 6,600.00 759.66 0.0174 225 1.24 0.55 7,407.45 6,750.00 657.45 0.0151 230 1.22 0.54 7,449.93 6,900.00 549.93 0.0126 235 1.21 0.54 7,549.49 7,050.00 499.49 0.0115 240 1.20 0.53 7,646.40 7,200.00 446.40 0.0102 Adjusted Runoff Coefficient (CC f ) Area (A ) Allowed Release Rate Required Detention Urban Storm Drainage Criteria Manual, Urban Drainage and Flood Control District, June 2001 (Revised April 2008) City of Fort Collins - Storm Water Criteria Manual June 6, 2018 Runoff Coefficient (C ) Frequency Factor (C f ) 100-yr Detention Volume - FAA Method Hoffman Mill Fuel Station J.Claeys Interwest Consulting 1344-095-00 (ft) SLOPE (ft/ft) Table RO-2 VELOCITY (ft/s) t c = t i + t t 0 . 5 V = C v S w V L tt 60 = �� = 18 − 15� + � 60 24� + 12 � �� = 1.87(1.1 − �� �� ) � � � 1344-095-00 Rational Calcs (FC).xlsx Page 3 of 4 Interwest Consulting Group (ft) SLOPE (ft/ft) Table RO-2 VELOCITY (ft/s) t c = t i + t t 0 . 5 V = C v S w V L tt 60 = �� = 18 − 15� + � 60 24� + 12 � �� = 1.87(1.1 − �� �� ) � � � 1344-095-00 Rational Calcs (FC).xlsx Page 2 of 4 Interwest Consulting Group LENGTH (ft) SLOPE (ft/ft) Table RO-2 VELOCITY (ft/s) t c = t i + t t 0 . 5 V = C v S w V L tt 60 = �� = 18 − 15� + � 60 24� + 12 � �� = 1.87(1.1 − �� �� ) � � � 1344-095-00 Rational Calcs (FC).xlsx Page 3 of 4 Interwest Consulting Group LENGTH (ft) SLOPE (ft/ft) Table RO-2 VELOCITY (ft/s) t c = t i + t t 0 . 5 V = C v S w V L tt 60 = �� = 18 − 15� + � 60 24� + 12 � �� = 1.87(1.1 − �� �� ) � � � 1344-095-00 Rational Calcs (FC).xlsx Page 2 of 4 Interwest Consulting Group Gravel/Pavers 1344-095-00 Rational Calcs (FC).xlsx Page 1 of 4 Interwest Consulting Group