HomeMy WebLinkAbout1608 WHEDBEE STREET, EXTRA OCCUPANCY - FDP - FDP180023 - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCE-CONCEPTUAL REVIEW (3)1
Community Development and
Neighborhood Services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov.com
August 31, 2018
Diane Erickson
Fort Collins, CO
Re: 1608 Whedbee St
Description of project: This is a request to use the existing single-family residence at 1608
Whedbee St as an extra-occupancy rental house with 4 tenants (parcel #9724208003). The
house has 4 bedrooms and 2.5 bathrooms. Four off-street parking spaces are provided
accessed from the driveway off Whedbee St. The property is within the Low-Density
Mixed-Use (LMN) zone district and is subject to Administrative (Type 1) review.
Please see the following summary of comments regarding the project request referenced
above. The comments offered informally by staff during the Conceptual Review will assist you
in preparing the detailed components of the project application. Modifications and additions
to these comments may be made at the time of formal review of this project. If you have any
questions regarding these comments or the next steps in the review process, you may contact
the individual commenter or direct your questions through the Development Review Coordinator,
Todd Sullivan, at 970-221-6695 or tsullivan@fcgov.com.
Comment Summary:
Planning Services
Contact: Shawna VanZee, 970-224-6086, svanzee@fcgov.com
1. When you submit your site plan for review, please provide a to scale drawing that shows
how many cars can fit in the new driveway configuration. Staff needs to ensure that you will
have enough space to fit three cars in the parking area given the minimum stall width
requirement. One additional parking space is required if the house is owner occupied.
Each parking space must have direct access to the abutting street and must be
unobstructed by any other parking space. (See Article 3.2.2 for reference) Please note
that vehicles should be parked on an existing or improved area having a surface of
2
asphalt, concrete, rock, gravel or other similar inorganic material, and such improved area
has a permanent border.
We are widening our driveway to accommodate three parked cars (with the minimum stall
width requirements met) whereby all parked cars also have direct access to the street.
See Attached: Exhibit A “Parking”, pages 1 & 2
2. This project requires four bicycle parking spaces on a fixed bicycle rack per Article 3.2.2
of the Land Use Code.
Permanently fixed bike rack for 4 bikes will be located inside the garage/shed.
3. The applicant should make note of Article 3.8.28 that allows no more than 25% of parcels
on a block face to be approved for Extra Occupancy Rental Houses in the LMN zone.
4. The proposed development project is subject to a Type 1 review and public hearing, the
decision maker for Type 1 hearings is an Administrative Hearing Officer. The applicant
for this development request is not required to hold a neighborhood meeting for a Type 1
hearing, but if you would like to have one to notify your neighbors of the proposal, please
let me know and I can help you in setting a date, time and location for a meeting.
Neighborhood Meetings are a great way to get public feedback and avoid potential
This property has been a rental since 1999 with no maintenance or upkeep. Our
neighbors are thrilled that we are working on it and bringing it back to life. They have
seen the time, effort, and money that we have put in to this property and they know our
strong pride of ownership will continue with tenants in residence.
No additional neighborhood meeting needed.
5. Please see the Development Review Guide at www.fcgov.com/drg. This online guide
features a color coded flowchart with comprehensive, easy to read information on each
step in the process. This guide includes links to just about every resource you need
during development review.
Reviewed
Property Address: 1608
Whedbee
1610 Whedbee
1612 Whedbee
1614 Whedbee
1616 Whedbee
1620 Whedbee
Owner Name &
Mailing Address:
(per Larimer
County Assessor)
Occupant:
Erickson
Tenant
Smiley
1610 Whedbee
Smiley
Goodell Trust
1612 Whedbee
Goodell
Kindsfather
1614 Whedbee
Kindsfather
Doughty
1616 Whedbee
Doughty
Pool
1620 Whedbee
Pool
3
6. This development proposal will be subject to all applicable standards of the Fort Collins
Land Use Code (LUC), including Article 3 General Development Standards. The entire
LUC is available for your review on the web at
http://www.colocode.com/ftcollins/landuse/begin.htm.
LUC reviewed with specifics noted from Article 3.
7. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a
Modification of Standard Request will need to be submitted with your formal development
proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply
for a Modification of Standard.
This proposal satisfies all the requirements set forth for compliance for an Extra
Occupancy permit, thus no Modification of Standards is being requested.
8. Please see the Submittal Requirements and Checklist at:
http://www.fcgov.com/developmentreview/applications.php.
Application forms are attached.
9. The request will be subject to the Development Review Fee Schedule that is available in
the Community Development and Neighborhood Services office. The fees are due at the
time of submittal of the required documents for the appropriate development review
process by City staff and affected outside reviewing agencies. Also, the required
Transportation Development Review Fee must be paid at time of submittal.
Required fee payment is submitted with this application.
10. When you are ready to submit your formal plans, please make an appointment with
Community Development and Neighborhood Services at (970)221-6750.
Acknowledged
Department: Erosion Control
Contact: Jesse Schlam, 970-218-2932, jschlam@fcgov.com
1. No Comment from Erosion Control at this time. Based upon the submitted Planning
Materials it has been determined that this site; disturbs less than 10,000 sq. ft., is not in
a sensitive area, has no steep slopes (greater than 3H:1V), and is not part of a larger
common development under construction. Therefore, no submittal of Erosion Control
Materials are needed at this time (if this site substantially changes in size or design
where the above criteria are anticipated, erosion control materials should be submitted
in such a case). Though the site at this time requires no erosion control material
submittal, it still must be swept and maintained to prevent dirt, saw cuttings, concrete
wash, trash & debris, landscape materials and other pollutants from entering the storm
sewer at all times in accordance with City Code 26-498 or erosion and sediment control
4
measures will be required of the site. Nearby area inlets should be protected as a good
preventative practice. If at building permit issuance any issues arise please email
erosion@fcgov.com to help facilitate getting these permits signed off. If you need
clarification concerning the Erosion Control Material Requirements or Comments
presented above please contact myself. Jesse Schlam (970) 224-6015
jschlam@fcgov.com
Acknowledged no submittal of Erosion Control Materials needed for submittal.
Department: Stormwater Engineering
Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com
1. MASTER PLAN AND CRITERIA COMPLIANCE (SITE SPECIFIC COMMENT):
The design of this site must conform to the drainage basin design of the Spring Creek
Master Drainage Plan as well the Fort Collins Stormwater Criteria Manual.
Acknowledged
2. DOCUMENTATION REQUIREMENTS (SITE SPECIFIC COMMENT):
If there is an increase in imperviousness greater than 1,000 square feet a drainage
report, erosion control report and construction plans are required and they must be
prepared by a Professional Engineer registered in the State of Colorado. The drainage
report must address the four-step process for selecting structural BMPs. If the increase
in impervious area is greater than 350 square feet and less than 1,000 square feet, a
drainage letter along with a grading and erosion control plan should be sufficient to
document the existing and proposed drainage patterns. A grading plan is required if the
increase in imperviousness is less than 350 square feet.
Driveway widening: 12’ x 62’ = 744sf x 40% (recycled asphalt) = 298sf
See Attachment: Exhibit B: “Grading & Drainage”
No grading has changed from the existing grading and drainage. The property to the south
has a very minimal slope on to subject property along the property line. The subject
property slopes very slightly eastward to the subject backyard, away from Whedbee Street.
Only the minimal area near the current driveway curb cut drains on to Whedbee.
3. STORMWATER OUTFALL (SITE SPECIFIC COMMENT):
Any additional stormwater generated by this development will need to be directed into
the roadway so as not to impact neighboring properties.
No additional stormwater generated that impacts neighboring properties. See above comments.
4. IMPERVIOUSNESS DOCUMENTATION (STANDARD COMMENT):
5
It is important to document the existing impervious area since drainage requirements
and fees are based on new impervious area. An exhibit showing the existing and
proposed impervious areas with a table summarizing the areas is required prior to the
time fees are calculated for each building permit.
Current driveway is concrete. Widened driveway is recycled asphalt.
See Attachment: Exhibit B “Grading & Drainage”
5. DETENTION REQUIREMENTS (STANDARD COMMENT):
When improvements are proposed to an existing developed site and there is an
increase in impervious area greater than 1000 square feet, onsite detention is required
with a 2-year historic release rate for water quantity. Parking lot detention for water
quantity is allowed as long as it is not deeper than one foot. If there is less than 1000 but
more than 350 square feet of new impervious area, a site grading plan is required along
with the impervious area documentation.
See Attachment: Exhibit B “Grading & Drainage”
6. STANDARD WATER QUALITY REQUIREMENTS (STANDARD COMMENT):
Fifty percent of the site runoff is required to be treated using the standard water quality
treatment as described in the Fort Collins Stormwater Manual, Volume 3-Best
Management Practices (BMPs).
(http://www.fcgov.com/utilities/business/builders-and-developers/development-forms-gui
delines-regulations/stormwater-criteria) Extended detention is the usual method
selected for water quality treatment; however the use of any of the BMPs is encouraged.
Acknowledged
7. LID REQUIREMENTS (STANDARD COMMENT):
Low Impact Development (LID) requirements are required on all new or redeveloping
property which includes sites required to be brought into compliance with the Land Use
Code. These require a higher degree of water quality treatment with one of the two
following options:
1. 50% of the newly added or modified impervious area must be treated by LID
techniques and 25% of new paved areas must be pervious.
2. 75% of all newly added or modified impervious area must be treated by LID
techniques.
Acknowledged
8. EROSION CONTROL REQUIREMENTS (STANDARD COMMENT):
The erosion control report requirements are in Section 1.3.3, Volume 3, Chapter 7 of the
6
Fort Collins Stormwater Criteria Manual. If you need clarification concerning this section,
please contact the Erosion Control Inspector, Jesse Schlam at 224-6015 or
jschlam@fcgov.com.
Acknowledged
9. INSPECTION AND MAINTENANCE (STANDARD COMMENT):
There will be a final site inspection of the stormwater facilities when the project is
complete and the maintenance is handed over to an HOA or another maintenance
organization. Standard operating procedures (SOPs) for on-going maintenance of all
onsite drainage facilities will be included as part of the Development Agreement. More
information and links can be found at:
http://www.fcgov.com/utilities/what-we-do/stormwater/stormwater-quality/low-impact-dev
elopement
Acknowledged - No HOA
10. FEES (STANDARD COMMENT):
Stormwater Development Fees include two components: Plant Investment Fees (PIFs)
and Review Fees.
1. PIFs (2018) are $8,217/acre of new impervious area over 350 square feet ($8,217 x
% imperviousness x site acreage)
2. Review Fees are $1,045/acre of new impervious area and based on the impervious
area rate factor (i.e. $1,045 x rate factor (based on % imperviousness) x site acreage)
Fees are to be paid at the time of the issuance of the first building permit. There are no
fees charged for existing impervious areas. Stormwater Development Fees for parking
lots or other projects that do not require a building permit are due prior to project
approval. The fees are calculated the same as for project sites with buildings. More
information on stormwater fees can be found at:
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-develo
pment-fees or contact our Utility Fee and Rate Specialists at (970) 416-4252 for
questions on fees.
Acknowledged
Department: Water-Wastewater Engineering
Contact: Shane Boyle, 970-221-6339, sboyle@fcgov.com
1. NO SITE IMPROVEMENTS? (SITE SPECIFIC COMMENT):
The application did not indicate any plans to increase or modify water or sewer services
to this site, so there are no Water or Sewer requirements. Please contact the Water
Utilities Engineering if service modifications are anticipated.
7
No modification to water or sewer services needed.
Department: Forestry
Contact: Molly Roche, mroche@fcgov.com
1. 1
8/27/2018:
There appears to be existing trees on-site. Please schedule an on-site meeting with City
Forestry to obtain tree inventory and mitigation information. Existing significant trees
should be retained to the extent reasonably feasible. This meeting should occur prior to
first-round PDP. Please state the plan for existing or proposed landscaping on-site.
2. 2
8/27/2018:
If applicable, please provide a landscape plan that meets the Land Use Code and 3.2.1
requirements. This should include, but is not limited to, including the City of Fort Collins
General Landscape Notes, Tree Protection Notes, and Street Tree Permit Note,
providing a detailed Plant List ¿ species, quantity, size, method of transplant, and
species percentage, and including current and proposed utility lines as well as proper
tree separation requirements. Please contact Molly Roche (mroche@fcgov.com) if you
have any questions.
Required tree sizes and method of transplant:
Canopy Shade Tree: 2.0¿ caliper balled and burlapped
Evergreen tree: 6.0¿ height balled and burlapped
Ornamental tree: 1.5¿ caliper balled and burlapped
If any mitigation is required, trees must be upsized to the following dimensions:
Canopy Shade Trees: 3.0" caliper balled and burlap or equivalent.
Evergreen Trees: 8' height balled and burlap or equivalent.
Ornamental Trees: 2.5" caliper balled and burlap or equivalent.
3. 3
8/27/2018:
If applicable, please include locations of any water or sewer lines on the landscape plan.
Please adjust street tree locations to provide for proper tree/utility separation.
10 between trees and public water, sanitary, and storm sewer main lines
6 between trees and public water, sanitary, and storm sewer service lines
4 between trees and gas lines
Acknowledged – Forestry has made an on-site inspection
.
Department: Fire Authority
Contact: Andrew Rosen, 970-416-2599, arosen@fcgov.com
1. ADDRESSING /WAYFINDING
The address is required to be clearly visible from the street in no less than 8" tall
numerals on a contrasting background.
8
New addressing was installed August14, 2018 before Conceptual review. It is 1)
located immediately next to front door, 2) situated under the covered porch light 3)
has clear & unobstructed visibility from Whedbee Street.
2. ACCESS
Access is required to within 150ft of all points of the external perimeter of the residence.
This requirement is met by measuring from Whedbee Street which is classified as a
collector street
Acknowledged
3. HYDRANT
A hydrant is required within 400ft of this residence. This criteria is satisfied by the
hydrant to the south.
Acknowledged
Department: Environmental Planning
Contact: Stephanie Blochowiak, 970-416-4290, sblochowiak@fcgov.com
1. City of Fort Collins Land Use Code [Section 3.2.1 (E)(3)], requires that to the extent
reasonably feasible, all plans be designed to incorporate water conservation materials
and techniques. This includes use of low-water-use plants and grasses in landscaping
or re-landscaping and reducing bluegrass lawns as much as possible. Native plants and
wildlife-friendly (ex: pollinators, butterflies, songbirds) landscaping and maintenance are
also encouraged. Please refer to the Fort Collins Native Plants document available
online and published by the City of Fort Collins Natural Areas Department for guidance
on native plants is: http://www.fcgov.com/naturalareas/pdf/nativeplants2013.pdf. Also
see the City of Fort Collins Plant List : https://www.fcgov.com/forestry/plant_list.pdf.
We have replaced several areas of old neglected lawn with new front brick walkway and
rear brick patio. Mulch is being added to the perimeter of the backyard for a much cleaner
and conservation of water layout. Low water perennials and bushes that are being added
include Karl Forester grasses, Autumn Sedum,Russian Sage, Barberry, etc.
2. Please submit a site photometric plan and luminaire schedule. In regard to outdoor
lighting, especially LED light fixtures, cooler color temperatures are harsher at night and
cause more disruption to circadian (biological) rhythms for both humans and wildlife.
Warmer color temperature (warm white, 3000K or less) for any LED light fixtures is
9
preferred. Please also consider fixtures with motion-sensing or dimming capabilities so
that light levels can be adjusted as needed. Site light sources shall be fully shielded and
down-directional to minimize up-light, light spillage and glare [see LUC 3.2.4(D)(3)].
Thank you in advance for supporting City of Fort Collins Night Sky Objectives. For further
information regarding health effects please see:
http://darksky.org/ama-report-affirms-human-health-impacts-from-leds/
New front porch LED lights (under the covered front porch) are downward directed with
warm lights.
3. Our city has an established identity as a forward-thinking community that cares about the
quality of life it offers its residents now and generations from now. Thus, the City of Fort
Collins has many sustainability programs and goals that may benefit this project. Of
particular interest may be the:
1) Green Building Program: http://www.fcgov.com/enviro/green-building.php, contact
Tony Raeker at 970-416-4238 or traeker@fcgov.com
2) Solar Energy: www.fcgov.com/solar, contact Rhonda Gatzke at 970-416-2312 or
rgatzke@fcgov.com
3) Integrated Design Assistance Program: http://fcgov.com/idap, contact Gary
Schroeder at 970-224-6003 or gschroeder@fcgov.com
Acknowledged
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mvirata@fcgov.com
1. If it is determined as part this process that the driveway would need to be widened at
Whedbee Street, a drive approach permit through Engineering would be required.
No driveway widening at Whedbee Street - keeping the original character of the
neighborhood with a single curb cut.
2. The proposal as an extra occupancy rental would not form a basis to require
development improvement obligations (such as sidewalk construction, right-of-way
dedication, etc.) Engineering would not require site improvements specific to this
proposal as a result. Should there be a change with the proposal, the following
comments may then be applicable and are included for reference.
Extra Occupancy application only
10
3. Larimer County Road Impact Fees and Transportation Expansion Fees are due at the
time of building permit. Please contact Kyle Lambrecht at 221-6566 if you have any
questions.
Acknowledged
4. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets,
sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of
this project, shall be replaced or restored to City of Fort Collins standards at the
Developer's expense prior to the acceptance of completed improvements and/or prior
to the issuance of the first Certificate of Occupancy.
Acknowledged
5. All public sidewalk, driveways and ramps, existing or proposed, adjacent or within the
site, need to meet ADA standards. If they currently do not, they will need to be
reconstructed so that they do meet current ADA standards as a part of this project.
Acknowledged
6. Any public improvements must be designed and built in accordance with the Larimer
County Urban Area Street Standards (LCUASS). They are available online at:
https://www.larimer.org/engineering/streets
Acknowledged
7. This project is responsible for dedicating any right-of-way and easements that are
necessary or required by the City for this project. Most easements to be dedicated need
to be public easements dedicated to the City. This shall include the standard utility
easements that are to be provided behind the right-of-way (15 foot along an arterial, 8
foot along an alley, and 9 foot along all other street classifications). Information on the
dedication process can be found at: http://www.fcgov.com/engineering/devrev.php
Acknowledged
8. Utility plans will be required and a Development Agreement will be recorded once the
project is finalized.
Acknowledged
9. As of January 1, 2015 all development plans are required to be on the NAVD88 vertical
datum. Please make your consultants aware of this, prior to any surveying and/or design
work.
Acknowledged
11
10. A Development Construction Permit (DCP) will need to be obtained prior to starting any
work on the site.
Acknowledged
11. All fences, barriers, posts or other encroachments within the public right-of-way are only
permitted upon approval of an encroachment permit. Applications for encroachment
permits shall be made to the Engineering Department for review and approval prior to
installation. Encroachment items shall not be shown on the site plan as they may not be
approved, need to be modified or moved, or if the permit is revoked then the site/
landscape plan is in non-compliance.
Acknowledged
12. In regards to construction of this site, the public right-of-way shall not be used for staging
or storage of materials or equipment associated with the Development, nor shall it be
used for parking by any contractors, subcontractors, or other personnel working for or
hired by the Developer to construct the Development. The Developer will need to find a
location(s) on private property to accommodate any necessary staging and/or parking
needs associated with the completion of the Development. Information on the
location(s) of these areas will be required to be provided to the City as a part of the
Development Construction Permit application.
Acknowledged
Department: Electric Engineering
Contact: Tyler Siegmund, 970-416-2772, tsiegmund@fcgov.com
1. Light and Power current serves this property with a #4TCU service from an existing oval
vault on the east side of Whedbee St, north of this property.
Acknowledged
2. Is an increase in electric capacity needed as part of this project?
No increase in electric capacity is needed.
If an increase in capacity is anticipated then electric capacity fees, development fees,
building site charges and system modification charges may apply to this project.
Please contact me or visit the following website for an estimate of charges and fees
related to an increase in capacity:
http://www.fcgov.com/utilities/business/builders-and-developers/plant-investment-develo
pment-fees
12
Acknowledged
3. Please contact Tyler Siegmund at Light & Power Engineering if you have any questions
at 970.416.2772. Please reference our policies, construction practices, development
charge processes, and use our fee estimator at
http://www.fcgov.com/utilities/business/builders-and-developers
Acknowledged
Department: Traffic Operations
Contact: Tim Tuttle, 970-221-6820, TTUTTLE@fcgov.com
1. The anticipated change in traffic volume is not expected to meet the threshold of
requiring a Traffic Impact Study. Based on section 4.2.2.E of the Larimer County Urban
Area Street Standards (LCUASS), the Traffic Impact Study can be waived.
Acknowledged
Department: Technical Services
Contact: Jeff County, 970-221-6588, jcounty@fcgov.com
1. As of January 1, 2015 all development plans are required to be on the NAVD88 vertical
datum. Please make your consultants aware of this, prior to any surveying and/or design
work. Please contact our office for up to date Benchmark Statement format and City
Vertical Control Network information.
Acknowledged
2. If submitting a replat for this property/project, addresses are not acceptable in the
Subdivision Plat title/name.
Acknowledged