Loading...
HomeMy WebLinkAboutFIRST STOP PLAZA - BASIC DEVELOPMENT REVIEW - BDR180031 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLANTREES QTY BOTANICAL NAME / COMMON NAME CONT CAL SIZE 3 CATALPA SPECIOSA / WESTERN CATALPA - 2" - 1 PRUNUS MAACKII / AMUR CHOKECHERRY - 1.5" - 2 TILIA CORDATA `GREENSPIRE` / GREENSPIRE LINDEN - 2" - SHRUBS QTY BOTANICAL NAME / COMMON NAME SIZE 6 ARCTOSTAPHYLOS X COLORADOENSIS `PANCHITO` / PANCHITO MANZANITA 5 GAL 42 CALAMAGROSTIS ARUNDINACEA BRACHYTRICHA / KOREAN FEATHER REED GRASS 5 GAL 18 PRUNUS BESSEYI `PAWNEE BUTTES` / SAND CHERRY 5 GAL PLANT SCHEDULE SIDEWALK CHASE 4'-0" LOT 2 EXISTING BUILDING 7714 SQ.FT. LOT 1 NORTH COLLEGE AVENUE SUNIGA ROAD 22'-0" 9'-0" 17'-0" 8'-0" 19'-7" 8'-0" 8'-0" 19'-0" 9'-0" 14'-0" 6 SPACES 10 SPACES (FOR USE BY LOT 2) RELOCATED MONUMENT SIGN EXISTING SIDEWALK CONCRETE WALK 9 SPACES RIGHT-OF-WAY LINE 24'-0" EXISTING LANDSCAPE TO REMAIN EXISTING BIKE RACK, SURFACE MOUNTED 27'-2" 24'-0" 7'-1" 20'-0" EMERGENCY ACCESS EASEMENT 20'-0" EMERGENCY ACCESS EASEMENT 9 SPACES R25'-0" 17'-0" R25'-0" R15'-0" DIRECTIONAL SIGN FOR LOT 2 / SIGN FOR LOT 1 EXISTING EMERGENCY ACCESS EASEMENT ROLL-OVER CURB FOR FIRE EXISTING LANDSCAPE TO REMAIN 14 SPACES 7'-3" PARKING SPACES SHALL BE FOR THE FUTURE USE OF LOT 1 ACCESSIBLE RAMP 01 HARDSCAPE SYMBOL DESCRIPTION PAVERS 02 LANDSCAPE MATERIAL SYMBOL DESCRIPTION WOOD MULCH IRRIGATED TURF ROCK MULCH NATIVE SEED 1 REFERENCE NOTES SCHEDULE DRAWING NUMBER: 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 phone 970.224.5828 | fax 970.225.6657 | www.ripleydesigninc.com ■ land planning ■ landscape architecture ■ ■ urban design ■ entitlement ■ ISSUED PROJECT No.: DRAWN BY: REVIEWED BY: SEAL: PREPARED BY: No. DESCRIPTION DATE REVISIONS No. DESCRIPTION DATE Plotted By: Stephanie Hansen Layout: 1 SITE PLAN Printed On: 9/25/2018 1:46 PM File Name: 1 SITE PLAN.dwg ORIGINAL SIZE 24X36 ENTITLEMENT DRAWINGS NOT FOR CONSTRUCTION RIPLEY DESIGN INC. Stephanie Hansen 419 Canyon Ave. Suite 200 Fort Collins, CO 80521 p. 970.224.5828 f. 970.225.6657 R and L Ventures, LLC Ron Flak 7559 Price Court Fort Collins, CO 80528 ENGINEER LAND PLANNER NORTHERN ENGINEERING Cody Snowdon 301 N. Howes St. Suite 100 Fort Collins, CO 80521 p. 970.221-4158 OWNER SITE PLAN BASIC DEVELOPMENT REVIEW 1ST STOP PLAZA 01 BDR 9/25/18 FORT COLLINS, CO SH R18-054 1 OF 1 NORTH 0 10 20 40 SCALE: 1"=20'-0" SITE PLAN NOTES 1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. MODIFICATIONS FOR LOT 1 A. BUILD-TO LINE SHALL BE BETWEEN 25' AND 35' FROM RIGHT-OF-WAY LINE OF SUNIGA ROAD. LUC 3.5.3(C)(2) B. 15' LANDSCAPE SETBACK FROM VEHICULAR USE AREAS SHALL SHALL BE EXEMPT. LUC 3.2.2.(J) C. DIRECT PEDESTRIAN CONNECTION TO SUNIGA ROAD SHALL BE EXEMPT. (LUC 3.2.2(C)(5) 7. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 8. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. A. VARIANCE FOR SIGNAGE ALLOWANCE TO ALLOW XX SQ.FT. OF SIGN FOR LOT 1 9. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 10. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 11. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 12. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS’ ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 13. PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODORCONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 14. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 15. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND Revised November 12, 2015 3 LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 16. SUNIGA ROAD CONSTRUCTION IS NOT INCLUDED IN THESE PLANS. PARKING Lot 2 (RETAIL) 38 EXISTING SPACES (5 SPACES / 1000 SQ.FT.) 34 PROPOSED SPACES (4.5 SPACES / 1000 SQ.FT.) Lot 1 (FUTURE USE TO BE DETERMINED) 0 EXISTING SPACES 14 PROPOSED SPACES