Loading...
HomeMy WebLinkAboutWATERFIELD FOURTH FILING - MAJOR AMENDMENT / PDP - PDP180009 - SUBMITTAL DOCUMENTS - ROUND 2 - UTILITY PLANSTIMBERLINE ROAD OLD VINE DRIVE LEMAY AVENUE PROJECT SITE OLD VINE DRIVE SEPTEMBER 2018 PRELIMINARY UTILITY PLANS FOR A REPLAT OF A PORTION OF WATERFIELD THIRD FILING AND TRACT A, WATERFIELD FIRST FILING, LOCATED IN THE WEST HALF OF SECTION 5, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO CONTACT INFORMATION PROJECT TEAM: Ripley Design, Inc. Katy Thompson 419 Canyon Avenue, Suite 200 Fort Collins, CO 80521 (970) 224-5828 UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER Northern Engineering Services, Inc. Cody Snowdon, PE 301 N. Howes St., Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 PLANNER/LANDSCAPE ARCHITECT VICINITY MAP NORTH SITE ENGINEER/ SURVEYOR PROJECT BENCHMARKS: SHEET INDEX COVER SHEET EXISTING CONDITIONS & DEMOLITION UTILITY SHEETS C2.00 OVERALL UTILITY PLAN GENERAL & CONSTRUCTION NOTES C0.00 C0.01-C0.02 C1.00-C1.01 EXISTING CONDITIONS PLAN CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ELCO Water District--------------------------------------------------------------------- (970) 493-2044 Boxelder Sanitation District------------------------------------------------------------ (970) 498-0604 Century Link------------------------------------------------------------------------------- (970) 445-4382 Xcel Energy--------------------------------------------------------------------------------(970) 225-7869 Xfinity----------------------------------------------------------------------------------------(970) 567-0245 City of Ft. Collins Utilities - Light & Power------------------------------------------(970) 212-2900 C2.01-C2.06 UTILITY PLANS THRIVE A. GENERAL NOTES 1. All materials, workmanship, and construction of ppublic improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the PRELIMNARY DRAINAGE REPORT FOR THRIVE DATED SEPTEMBER 5, 2018 by Northern Engineering Services, Inc., shall be followed and implemented. 16' 7' PARK TRAVEL 7' PARK 6' (MIN.) PKWY 30' ROADWAY 51' ROW (MIN.) (MIN) WALK 4.5' 6'.5 Min. Fence Setback UTIL. ESMT. 9' 9' UTIL. ESMT. (MIN.) PKWY 6' WALK (MIN) 4.5' 10' 10' 10' 8' TRAVEL PARK TRAVEL 8' PARK TRAVEL TURN 13' TRAVEL 13' LEFT 6' (MIN.) PKWY 36' ROADWAY 57' ROW (MIN.) (MIN) WALK 4.5' 6.5' MIN. FENCE SETBACK UTIL. ESMT. 9' 9' UTIL. ESMT. 36' ROADWAY (MIN) WALK 4.5' (MIN.) PKWY 6' H2O WV WV V.P. WV WV H2O V.P. TEST STA V.V.P. P. H2O H2O WV H2O WV H2O TEST STA GAS H Y D W WV WV WVWWVV WV WV V.P. C S H2O TEST STA W TH TH TH TH TH X X X X X X X X X X X X X X X X X X X X X X OHE OHE OHE OHE ST WV VAULT CABLE TELE TEST STA D WV WV S VAULT CABLE S D D TELE S VAULT ELEC V.P. ELEC ELEC V.P. V.P. ELEC BRKR ELEC ELEC S H2O S S S S GAS VAULT ELEC V.P. WV VAULT ELEC WV VAULT ELEC WV WV WV WV V.P. WV WV H2O WV V.WV P. ELEC ELEC E GAS T VAULT WV H2O V.P. TEST STA V.V.P. P. H2O H2O WV TH TH TH X X X X X X X X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE W W W W W W W W W W W W W W W W W W W W W W W W W W W H2O WV WV V.P. WV TEST STA V.P. ELEC ELEC V.P. E E E E TH TH TH TH X X X X X X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE IRR IRR IRR IRR IRR IRR W W W W W W W W W W W W W W W H 2O S H2O WV S V.P. WV WV H2O WV V.WV P. ELEC ELEC E GAS T VAULT ELEC SS SS SS SS SS SS TH TH TH X X X X X X X X X X X X X X X X X X X X X X X W W W W W 20' SUBDRAIN EASEMENT REC. NO. 2000049500 TO BE VACATED 20' SUBDRAIN EASEMENT REC. NO. 2000049500 TO BE VACATED SCRUB TREE AREA TO BE REMOVED EXISTING SANITARY MH PDI 0820 RIM=4958.17 INV. 10" PVC (N)=4945.64 INV. 10" PVC (S)=4945.40 TO BE REMOVED EXISTING LIGHT POLE TO BE RELOCATED EXISTING SIGN TO BE REMOVED EXISTING SIGNS TO WV VAULT ELEC V.P. ELEC ELEC V.P. V.P. ELEC BRKR ELEC ELEC S H2O S S S VAULT ELEC WV WV WV WV V.P. WV WV H2O WV V.WV P. ELEC ELEC E GAS T VAULT ELEC VAULT C ELEC SS SS SS SS SS SS SS SS SS SS E E E E E TH TH TH TH TH TH OHE OHE OHE OHE OHE OHE OHE OHE VAULT CABLE TELE TEST STA D WV WV S GAS SS SS SS TH TH X X X X X X X X X X X X X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE G G G G G G G G G G G ST ST ST ST ST S VAULT CABLE S D D TELE S S H2O S S S S VAULT ELEC V.P. WV VAULT ELEC WV VAULT ELEC WV WV WV WV V.P. WV WV H2O WV V.WV P. ELEC ELEC E GAS T VAULT ELEC VAULT C ELEC SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS H2O WV WV WV WV WV H2O V.P. TEST STA V.P. H2O H2O WV VAULT CABLE TELE TEST STA WV WV S VAULT CABLE S D D TELE S VAULT ELEC ELEC ELEC V.P. ELEC BRKR ELEC ELEC S S S H2O WV GAS H2O TEST STA GAS H Y D W WV WV WVWWVV WV WV V.P. C S H2O TEST STA 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W N YLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS 8" W WV H2O TEST STA H2O H2O WV W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W 12" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W UD UD UD UD 8" W ELEC ELEC E GAS T VAULT ELEC 8" PVC WATER FIRE HYDRANT ASSEMBLY 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR 8" W 8" W 8" W 14" W 14" W 14" W 14" W 14" W 14" W 14" W 14" W 14" W 14" W 14" W 14" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 6" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 14" W 14" W 14" W 14" W 14" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 14" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W UD UD UD UD VAULT CABLE TELE TEST STA WV WV S GAS SS SS SS X X X X X X X X X X X X X X 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 14" W 14" W 14" W 14" W 14" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 8" W ST ST ST ST S VAULT CABLE S D D TELE S S S S VAULT ELEC WV VAULT ELEC WV WV WV ELEC ELEC E GAS T VAULT ELEC VAULT C ELEC SS SS SS H2O WV WV WV WV WV H2O V.P. TEST STA V.P. H2O H2O WV VAULT CABLE TELE TEST STA WV WV S VAULT CABLE S D D TELE S VAULT ELEC ELEC ELEC V.P. ELEC BRKR ELEC ELEC S S S H2O WV GAS H2O TEST STA GAS H Y D W WV WV WVWWVV WV WV V.P. C S H2O TEST STA NYLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE 80.75 79.59 78.29 78.95 76.42 74.73 77.39 75.57 72.97 73.81 76.45 71.12 73.63 69.28 71.69 69.72 67.43 65.68 67.84 66.18 64.26 63.23 64.91 62.86 61.92 62.44 64.79 63.80 80.81 73.34 72.29 81.46 80.76 81.15 70.47 80.51 79.12 68.77 77.19 66.73 IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR N YLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS X X X X X X X X X OHE OHE OHE OHE H2O 60.44 61.80 63.73 63.34 62.78 61.80 62.47 61.54 62.84 63.52 64.16 64.52 65.03 65.28 65.55 69.53 63.52 64.44 64.29 63.32 63.48 65.55 67.17 60.36 61.71 59.55 60.13 60.36 58.97 60.70 60.30 59.33 58.97 UD UD UD UD 53.84 56.85 56.74 55.53 56.04 57.12 60.70 58.57 55.29 58.00 58.98 58.00 52.80 52.33 57.04 55.36 56.07 58.94 57.57 57.40 57.84 57.64 51.98 52.98 52.42 53.42 54.30 53.30 53.30 54.30 52.39 53.39 52.00 52.99 51.68 52.68 52.54 51.54 53.15 52.78 53.78 53.08 54.08 53.35 53.41 55.05 54.05 55.05 54.05 54.14 53.14 53.53 52.53 52.28 52.98 52.99 52.98 IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR BULL RUN APARTMENTS TIMBERLINE ROAD C IRR IRR IRR IRR H2O IRR IRR IRR IRR D 59.11 57.12 60.41 60.44 61.80 61.53 58.42 55.43 54.37 60.74 60.26 60.94 63.73 63.34 62.78 61.80 62.47 61.54 62.84 61.76 61.52 60.89 59.89 57.45 52.60 53.54 53.73 53.56 54.75 58.78 58.35 54.31 54.23 59.76 59.89 60.00 59.16 59.50 58.89 58.35 59.62 59.32 59.50 59.40 61.10 61.19 63.52 UD UD UD UD OLD VINE DRIVE VAULT CABLE X X X X X X X X X X X X X X X X X X X OHE OHE OHE G G G G G G G G G G G G G G 51.13 51.25 53.36 52.91 53.19 51.75 50.05 49.02 50.55 51.04 51.04 51.34 51.77 51.41 48.69 50.05 49.10 49.31 49.31 49.34 49.43 50.91 50.14 53.30 53.34 53.37 53.52 52.71 BULL RUN APARTMENTS ST ST ST ST VAULT CABLE D D C 51.13 51.25 50.45 50.48 53.05 53.17 52.65 55.78 50.79 56.61 58.98 53.36 52.91 53.19 51.75 50.05 49.02 50.55 51.04 51.04 51.34 54.93 55.87 57.65 58.11 58.65 58.19 58.11 58.43 59.57 60.75 59.11 47.36 47.04 47.00 51.60 51.68 49.68 49.83 52.96 53.04 52.34 52.50 55.82 55.67 53.18 54.10 52.50 52.34 51.60 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 9+50 10+00 11+00 12+00 13+00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4960.80 4960.25 4959.74 4959.23 4958.81 4958.53 4958.38 4958.38 4958.49 4959.05 2.25% -2.25% -2.04% 0.50% PVI STA = 10+00.00 PVI ELEV = 4960.80 PVI STA = 10+16.00 PVI ELEV = 4960.44 PVI STA = 12+00.18 PVI ELEV = 4958.49 PVI STA = 12+30.68 PVI ELEV = 4959.17 114.5' VC LP ELEV = 4958.36 LP STA = 11+63.51 PVI STA = 11+28.76 PVI ELEV = 4958.13 BCVS: 10+71.51 BVCE: 4959.30 ECVS: 11+86.01 EVCE: 4958.42 A.D. = 2.54 K = 45.00 STORM DRAIN MH STREET A 30' -  4965 4970 4975 4980 4985 4990 4965 4970 4975 4980 4985 4990 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4981.33 4980.43 4979.52 4978.62 4977.72 4975.77 4971.97 4981.10 4980.88 4980.65 4980.20 4979.98 4979.75 4979.30 4979.07 4978.85 4978.40 4978.17 4977.95 4977.44 4977.02 4976.47 4974.94 4973.97 4972.97 4970.99 -0.90% -4.00% PVI STA = 10+00.00 PVI ELEV = 4981.33 139.4' VC PVI STA = 14+72.78 PVI ELEV = 4977.06 BCVS: 14+03.09 BVCE: 4977.69 ECVS: 15+42.47 EVCE: 4974.28 A.D. = 3.10 K = 45.00 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 16+50 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+50 4968.83 4967.89 4968.44 4967.77 4965.78 4965.03 4964.01 4963.28 4962.54 4969.41 4968.38 4968.08 4967.91 4968.00 4968.15 4968.30 4968.48 4968.38 4968.14 4967.28 4966.78 4966.28 4965.28 4964.78 4964.63 4964.47 4964.38 4964.20 4963.83 4963.64 4963.46 4963.09 4962.91 4962.72 4962.35 0.60% 2.25% -2.25% -2.00% -0.74% PVI STA = 21+96.52 PVI ELEV = 4965.11 PVI STA = 21+66.52 PVI ELEV = 4964.43 PVI STA = 22+26.52 PVI ELEV = 4964.43 117.0' VC 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 25+50 26+00 27+00 28+00 29+00 30+00 30+50 4961.80 4961.06 4959.67 4959.60 4961.98 4961.62 4961.43 4961.25 4960.81 4960.49 4960.09 4959.40 4959.31 4959.40 4959.80 4960.00 4960.20 -1.80% 0.80% -0.74% PVI STA = 29+98.90 PVI ELEV = 4960.39 90.0' VC PVI STA = 27+36.04 PVI ELEV = 4960.80 BVCS: 26+91.04 BVCE: 4961.13 EVCS: 27+81.04 EVCE: 4959.99 A.D. = 1.06 K = 84.76 90.0' VC LP ELEV = 4959.31 LP STA = 28+49.85 PVI STA = 28+32.54 PVI ELEV = 4959.06 BCVS: 27+87.54 BVCE: 4959.87 ECVS: 28+77.54 EVCE: 4959.42 A.D. = 2.60 K = 34.62 PROPOSED GRADE EXISTING GROUND PROPOSED 4955 4960 4965 4970 4975 4980 4955 4960 4965 4970 4975 4980 9+50 10+00 11+00 12+00 13+00 14+00 15+00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4968.41 4969.56 4971.36 4973.16 4974.96 4968.21 4968.66 4969.11 4970.01 4970.46 4970.91 4971.81 4972.26 4972.71 4973.61 4974.06 4974.51 4975.41 4975.86 4976.31 -2.25% 1.80% PVI STA = 10+00.00 PVI ELEV = 4968.41 PVI STA = 10+16.00 PVI ELEV = 4968.05 ALLEY 9 ALLEY 11 36' -  57' ROW 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER STREET B SEE SHEET C4.02 STREET B 4965 4970 4975 4980 4985 4990 4965 4970 4975 4980 4985 4990 18+50 19+00 20+00 21+00 21+50 4979.54 4976.63 4973.63 4980.08 4978.88 4978.13 4977.38 4975.88 4975.13 4974.38 4973.11 2.25% -2.25% -3.00% PVI STA = 21+41.12 PVI ELEV = 4973.48 PVI STA = 21+21.12 PVI ELEV = 4973.02 EVCS: 19+29.73 EVCE: 4978.74 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND STREET C ALLEY 10 ALLEY 11 ∆ ALLEY 9 STREET D SEE SHEET C4.07 ALLEY 9 ALLEY 8 ALLEY 8 36'  - 57' ROW 30" VERTICAL CURB AND GUTTER 36' - 57' ROW 30" VERTICAL CURB AND GUTTER 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 18+50 4959.87 4959.69 4960.19 4960.69 4961.19 4961.69 4962.19 4962.69 4963.19 4963.78 4964.37 4964.90 4965.35 4965.74 4966.09 4966.44 4966.79 4967.14 4967.49 4967.84 4968.19 4968.54 4968.89 4969.24 4969.59 4969.94 4970.29 4970.64 4970.99 4971.30 4971.56 4971.77 4971.93 4972.08 -2.25% 1.40% 2.00% 2.40% 0.60% PVI STA = 10+00.00 PVI ELEV = 4959.87 PVI STA = 10+16.00 PVI ELEV = 4959.51 PVI STA = 12+00.93 PVI ELEV = 4963.21 90.0' VC PVI STA = 17+42.36 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 18+50 19+00 20+00 21+00 22+00 23+00 23+50 4972.53 4973.13 4973.73 4974.33 4974.93 4972.38 4972.68 4972.83 4972.98 4973.28 4973.43 4973.58 4973.88 4974.03 4974.18 4974.48 4974.63 4974.78 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 0.60% PVI STA = 23+16.56 PVI ELEV = 4975.03 RCP STORM IRR IRR IRR IRR IRR IRR STREET D STREET C SEE SHEET C4.05 18'  - 80' ROW 18' -  30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 9+50 10+00 11+00 12+00 13+00 13+50 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4979.89 4975.75 4971.25 4966.75 4979.12 4978.00 4976.87 4974.62 4973.50 4972.37 4970.12 4969.00 4967.87 4965.72 -2.25% -4.50% PVI STA = 10+00.00 PVI ELEV = 4979.89 PVI STA = 10+16.00 PVI ELEV = 4979.53 BCVS: 12+95.13 BVCE: 4966.97 STREET E 30" VERTICAL CURB AND GUTTER 36'  -  57' ROW STREET B ALLEY 13 SEE SHEET C4.01 STREET F SEE SHEET C4.11 ALLEY 12 ALLEY 12 ∆ ∆ STOP SIGN 4.5' SIDEWALK 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 18+50 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 27+50 4958.43 4959.40 4959.03 4957.53 4956.03 4955.53 4955.96 4957.96 4959.96 4958.18 4958.68 4958.93 4959.18 4959.50 4959.47 4959.32 4958.65 4958.28 4957.90 4957.15 4956.78 4956.40 4955.70 4955.50 4955.45 4955.91 4956.15 4955.58 4956.46 4956.96 4957.46 4958.46 4958.96 4959.46 4960.43 2.25% -2.25% 2.00% 1.00% -1.50% 0.80% PVI STA = 24+42.77 PVI ELEV = 4956.31 PVI STA = 24+78.27 PVI ELEV = 4955.50 PVI STA = 24+12.16 PVI ELEV = 4955.62 4940 4945 4950 4955 4960 4965 4940 4945 4950 4955 4960 4965 27+50 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 4961.12 4960.52 4959.61 4958.70 4957.78 4956.87 4955.96 4961.01 4961.11 4960.98 4960.75 4960.30 4960.07 4959.84 4959.38 4959.15 4958.93 4958.47 4958.24 4958.01 4957.56 4957.33 4957.10 4956.64 4956.41 4956.19 4955.73 -0.91% PVI STA = 34+40.59 PVI ELEV = 4955.59 150.0' VC HP ELEV = 4961.13 HP STA = 28+10.11 PVI STA = 27+82.14 PVI ELEV = 4961.60 EVCS: 28+57.14 EVCE: 4960.92 A.D. = 2.91 K = 51.48 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4960 4965 4970 4975 4980 4985 4960 4965 4970 4975 4980 4985 9+50 10+00 11+00 12+00 13+00 13+50 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4981.33 4981.56 4981.75 4981.76 4981.56 4981.15 4980.53 4979.71 4978.67 4977.46 4976.21 4974.96 4973.71 4972.46 0.90% -5.00% PVI STA = 10+00.00 PVI ELEV = 4981.33 177.0' VC HP ELEV = 4981.78 HP STA = 10+63.50 PVI STA = 11+25.00 PVI ELEV = 4982.46 BVCS: 10+36.50 BVCE: 4981.66 EVCS: 12+13.50 EVCE: 4978.03 A.D. = 5.90 K = 30.00 STREET F STREET F W W W W W W W W W W 31" DRIVE-OVER 4940 4945 4950 4955 4960 4965 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4953.27 4952.70 4952.38 4952.13 4951.88 4951.63 4951.38 4951.13 4950.88 4950.63 4950.38 4950.13 4949.88 4949.63 4949.38 4949.13 4948.88 4948.63 4948.37 4948.09 4947.82 4947.55 4947.37 4947.33 4947.44 4947.61 4947.79 4947.96 4948.14 4948.31 4948.49 4948.66 4948.84 4949.01 4949.19 4949.55 2.25% -2.25% -1.00% 4940 4945 4950 4955 4960 4965 4940 4945 4950 4955 4960 4965 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 17+50 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4953.99 4953.43 4953.26 4953.13 4953.01 4952.88 4952.76 4952.63 4952.51 4952.38 4952.24 4952.09 4951.94 4951.79 4951.64 4951.49 4951.34 4951.19 4951.04 4950.89 4950.74 4950.59 4950.44 4950.29 4950.14 4949.99 4949.84 4949.69 4949.54 4949.39 4949.24 -2.25% -0.50% -0.60% PVI STA = 10+00.00 PVI ELEV = 4953.99 PVI STA = 10+35.50 PVI ELEV = 4953.18 PVI STA = 12+31.83 4940 4945 4950 4955 4960 4965 4940 4945 4950 4955 4960 4965 17+50 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 25+50 4948.94 4948.77 4950.44 4952.40 4954.36 4956.32 4958.29 4960.25 4949.09 4948.79 4948.64 4949.06 4948.97 4949.46 4949.95 4950.93 4951.42 4951.91 4952.89 4953.38 4953.87 4954.85 4955.34 4955.83 4956.82 4957.31 4957.80 4958.78 4959.27 4959.76 2.25% -2.25% 1.96% 4.73% -0.60% PVI STA = 18+80.91 PVI ELEV = 4949.20 PVI STA = 19+06.91 PVI ELEV = 4948.61 PVI STA = 25+02.49 PVI ELEV = 4960.30 PVI STA = 25+18.49 PVI ELEV = 4961.06 PVI STA = 18+54.91 PVI ELEV = 4948.61 PROPOSED GRADE EXISTING 4940 4945 4950 4955 4960 4965 4940 4945 4950 4955 4960 4965 0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 9+50 FUTURE GRADE FUTURE GRADE 0.60% -0.60% 1.40% 190.0' VC HP ELEV = 4950.38 HP STA = 3+49.11 PVI STA = 3+49.11 PVI ELEV = 4950.66 BVCS: 2+54.11 BVCE: 4950.09 EVCS: 4+44.11 EVCE: 4950.09 A.D. = 1.20 K = 158.33 230.0' VC LOW PT ELEV = 4949.12 LOW PT STA = 6+40.25 PVI STA = 6+86.25 PVI ELEV = 4948.64 BVCS: 5+71.25 BVCE: 4949.33 EVCS: 8+01.25 EVCE: 4950.25 A.D. = 2.00 K = 115.00 EXISTING GROUND 4948.72 4948.87 4949.02 4949.17 4949.32 4949.47 4949.62 4949.77 4949.92 4950.07 4950.20 4950.30 4950.36 4950.38 4950.35 4950.29 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 18+50 PROPOSED GRADE EXISTING PROPOSED GROUND GRADE EXISTING GROUND 25.00% 0.60% -0.60% 0.60% -0.60% PVI STA = 10+42.54 PVI ELEV = 4950.93 PVI STA = 10+53.14 PVI ELEV = 4953.59 180.0' VC HP ELEV = 4954.03 HP STA = 11+72.30 PVI STA = 11+72.30 PVI ELEV = 4954.30 BVCS: 10+82.30 BVCE: 4953.76 EVCS: 12+62.30 EVCE: 4953.76 A.D. = 1.20 K = 150.00 190.0' VC HP ELEV = 4954.04 HP STA = 15+81.92 PVI STA = 15+81.92 PVI ELEV = 4954.32 BVCS: 14+86.92 BVCE: 4953.75 EVCS: 16+76.92 EVCE: 4953.75 A.D. = 1.20 K = 158.33 150.0' VC LP ELEV = 4953.31 LP STA = 13+75.19 PVI STA = 13+75.19 PVI ELEV = 4953.08 BCVS: 13+00.19 BVCE: 4953.53 ECVS: 14+50.19 EVCE: 4953.53 4945 4950 4955 4960 4965 4970 4945 4950 4955 4960 4965 4970 18+50 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 28+50 ECVS: 19+00 EVCE: 4953.28 EXISTING GROUND PROPOSED GRADE EXISTING GROUND PROPOSED GRADE 4953.16 4953.28 4953.42 4953.55 4953.69 4953.83 4953.96 4954.10 4954.24 4954.38 4954.52 4954.65 4954.79 4954.93 4955.06 4955.20 4955.34 4955.48 4955.62 4955.75 4955.89 4956.03 4956.16 4956.30 4956.44 4956.58 4956.72 4956.85 4956.99 4957.13 4957.26 4957.40 4957.54 4957.68 4957.82 4957.95 4958.09 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 28+50 29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 37+00 38+00 38+50 0.55% 0.50% -0.50% PVI STA = 29+11.81 PVI ELEV = 4958.84 PVI STA = 36+37.75 PVI ELEV = 4961.67 150.0' VC HP ELEV = 4961.88 HP STA = 35+57.75 PVI STA = 35+57.75 PVI ELEV = 4962.07 BVCS: 34+82.75 BVCE: 4961.70 EVCS: 36+32.75 EVCE: 4961.70 A.D. = 1.00 K = 150.00 0.88% 2.27% -2.17% -0.60% PVI STA = 36+87.58 PVI ELEV = 4963.50 PVI STA = 37+28.25 PVI ELEV = 4964.43 PVI STA = 37+68.95 PVI ELEV = 4963.54 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND FUTURE GRADE 4958.64 4958.78 4958.91 4959.03 4959.16 4959.28 4959.41 4959.53 4959.66 4959.78 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 38+50 39+00 40+00 41+00 42+00 43+00 44+00 45+00 46+00 47+00 48+00 48+50 -0.60% 0.60% 150.0' VC LOW PT ELEV = 4959.46 LOW PT STA = 44+86.69 PVI STA = 44+86.69 PVI ELEV = 4959.24 BVCS: 44+11.69 BVCE: 4959.69 EVCS: 45+61.69 EVCE: 4959.69 A.D. = 1.20 K = 125.00 FUTURE GRADE FUTURE GRADE EXISTING GROUND 4962.91 4962.76 4962.61 4962.46 4962.31 4962.16 4962.01 4961.86 4961.71 4961.56 4961.41 4961.26 4961.11 4960.96 4960.81 4960.66 4960.51 4960.36 4960.21 4960.06 4959.91 4959.76 4959.61 4959.52 4959.47 4959.47 4959.52 4959.62 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 48+50 49+00 50+00 51+00 52+00 53+00 54+00 55+00 56+00 56+50 FUTURE GRADE FUTURE GRADE 0.60% PVI STA = 56+13.94 PVI ELEV = 4966.00 EXISTING GROUND EXISTING GROUND 4961.57 4961.72 4961.87 4962.02 4962.17 4962.32 4962.47 4962.62 4962.77 4962.92 4963.07 4963.22 4963.37 4963.52 4963.67 4963.82 4963.97 4964.12 4964.27 4964.42 4964.57 4964.72 4964.87 4965.02 4965.17 4965.32 4965.47 4965.62 4965.77 4965.92 65'  -  115' ROW FUTURE 30" VERTICAL WV VAULT ELEC V.P. ELEC BRKR ELEC ELEC E TH TELE IRR IRR IRR IRR IRR IRR IRR IRR W W W W W W W W W W W W W W W W W W W W W W W W W W H 2O GAS GAS IRR IRR IRR IRR IRR D D D IRR IRR IRR IRR IRR IRR IRR IRR EXISTING TIMBERLINE ROAD TRACT H TRACT J A A EXISTING TIMBERLINE ROAD EDGE OF ASPHALT ASPHALT WIDENING EXISTING TIMBERLINE ROAD EDGE OF ASPHALT EXISTING TIMBERLINE ROAD EDGE OF ASPHALT SUNIGA ROAD SEE SHEET C4.18 PROPOSED INTERIM EDGE OF ASPHALT H2O WV WV WV ELEC ELEC E E E E TH X OHE OHE OHE OHE OHE W W W W W W W W W W W W W W W W W H 2O IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR EXISTING TIMBERLINE ROAD PROPOSED 6' SIDEWALK TRACT H TRACT K A A PROPOSED 6' SIDEWALK EXISTING TIMBERLINE ROAD EDGE OF ASPHALT ASPHALT WIDENING STREET D SEE SHEET C4.07 30" VERTICAL CURB & GUTTER (TYP.) PROPOSED ASPHALT TRANSITION 30" VERTICAL CURB & GUTTER (TYP.) EXISTING TIMBERLINE ROAD EDGE OF ASPHALT EXISTING BRIDGE CENTER SECTION LINE EXISTING EDGE FUTURE 30" VERTICAL CURB & GUTTER (TYP.) FUTURE 18" OUTFALL (MEDIAN) CURB & GUTTER 115' ROW 83' - 19' - MEDIAN FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK FUTURE 30" VERTICAL CURB & GUTTER (TYP.) TIMBERLINE ROAD FUTURE 6' SIDEWALK EXISTING 60' ROW TIMBERLINE RD EXISTING EDGE OF PAVEMENT EXISTING DRIVE CENTER SECTION LINE EXISTING EDGE OF ASPHALT EXISTING 60' ROW TIMBERLINE RD ∆ 4925 4930 4935 4940 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 4925 4930 4935 4940 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 9+00 10+00 11+00 12+00 13+00 14+00 15+00 16+00 16+50 0.80% 2.20% 4.80% PVI STA = 10+00.00 R FUTURE 30" VERTICAL CURB & GUTTER (TYP.) FUTURE 18" OUTFALL (MEDIAN) CURB & GUTTER 115' ROW 83' - 19' - MEDIAN FUTURE 6' SIDEWALK TIMBERLINE ROAD FUTURE 6' SIDEWALK FUTURE 30" VERTICAL CURB & GUTTER (TYP.) VINE DRIVE FUTURE 6' SIDEWALK EXISTING BNSF RAILROAD TRACKS FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT EXISTING EDGE OF PAVEMENT EXISTING 60' ROW ∆ 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 4995 5000 5005 5010 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 4995 5000 5005 5010 16+50 17+00 18+00 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 4.80% 1000.0' VC HP ELEV = 4988.46 HP STA = 23+09.45 PVI STA = 22+63.99 PVI ELEV = 4999.37 IRR IRR IRR WV VAULT ELEC V.P. ELEC BRKR ELEC ELEC TELE W W W W W W W W W W W W W W W W W W W W W W W W W H2O GAS GAS FUTURE 18" OUTFALL (MEDIAN) CURB & GUTTER TIMBERLINE ROAD 115' ROW 83' - 19' - MEDIAN FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK FUTURE 30" VERTICAL CURB & GUTTER (TYP.) FUTURE 30" VERTICAL CURB & GUTTER (TYP.) 36.35' EXISTING TIMBERLINE ROAD EDGE OF ASPHALT FUTURE 6' SIDEWALK TIMBERLINE ROAD TRACT H 10' TRAIL SUNIGA ROAD SEE SHEET C4.18 IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR H2O WV WV WV ELEC ELEC ELEC BRKR ELEC ELEC E E E E E E TH X OHE OHE OHE OHE OHE W W W W W W W W W W W W W W W W W W W W H 2O TIMBERLINE ROAD PROPOSED 30" VERTICAL CURB & GUTTER (TYP.) FUTURE 18" OUTFALL (MEDIAN) CURB & GUTTER 115' ROW 83' - 19' - FUTURE 30" VERTICAL CURB & GUTTER (TYP.) PROPOSED 30" VERTICAL CURB & GUTTER (TYP.) FUTURE 30" VERTICAL CURB & GUTTER (TYP.) 35.85' EXISTING TIMBERLINE ROAD EDGE OF ASPHALT OHE TIMBERLINE ROAD FUTURE 18" OUTFALL (MEDIAN) CURB & GUTTER 115' ROW 83' - 19' - MEDIAN FUTURE 30" VERTICAL CURB & GUTTER (TYP.) FUTURE 30" VERTICAL CURB & GUTTER (TYP.) FUTURE 6' SIDEWALK FUTURE 6' SIDEWALK FUTURE 15' UTILITY EASEMENT FUTURE 15' UTILITY EASEMENT FUTURE 18" OUTFALL (MEDIAN) CURB & GUTTER EXISTING BRIDGE 4970 4975 4980 4985 4990 4995 5000 4970 4975 4980 4985 4990 4995 5000 45+00 46+00 47+00 48+00 49+00 50+00 51+00 52+00 53+00 54+00 54+50 1.30% 1.00% 0.80% -0.60% PVI STA = 45+26.66 PVI ELEV = 4984.29 PVI STA = 46+79.03 PVI ELEV = 4985.82 PVI STA = 54+18.86 PVI ELEV = 4987.63 400.0' VC HP ELEV = 4988.70 HP STA = 51+53.94 PVI STA = 51+25.00 PVI ELEV = 4989.38 BVCS: 49+25 BVCE: 4987.78 EVCS: 53+25 EVCE: 4988.19 A.D. = 1.40 K = 286.17 FUTURE GRADE EXISTING GROUND EXISTING GROUND ELEVATION (TYP.) UD IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR N YLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS V.P. TEST STA V.P. TELE TEST STA D D TELE V.P. GAS TEST STA GAS V.P. TEST STA V.P. V.P. GAS T X X X X X X X X X X X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE TELE GAS TELE R R IRR IRR H2O GAS GAS H2O IRR D D D UD IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR N YLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS 1 2 3 4 5 8 9 8 9 5 4 2 3 1 7 OS1 OS2 OS2 OS1 6 6 7 FOREBAY 1 FOREBAY 2 BIOSWALE APPROXIMATE EDGE OF WATER FOREBAY 3 STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN APPROXIMATE EDGE OF WETLANDS SWALE STORM DRAIN STORM DRAIN TIMBERLINE ROAD MERGANSER STREET A STREET B STREET B STREET C STREET C STREET C STREET D STREET D STREET E STREET E STREET E STREET F STREET F ALLEY 2 ALLEY 1 ALLEY 3 ALLEY 4 ALLEY 4 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 5 ALLEY 6 ALLEY 7 ALLEY 9 ALLEY 9 ALLEY 9 ALLEY 12 ALLEY 10 ALLEY 10 ALLEY 11 ALLEY 13 ALLEY 13 STREET G STREET G STREET H STREET H STREET H ALLEY 15 ALLEY 15 ALLEY 16 ALLEY 16 ALLEY 16 ALLEY 16 ALLEY 17 ALLEY 18 ALLEY 19 ALLEY 20 ALLEY 21 ALLEY 16 ALLEY 22 ALLEY 23 ALLEY 24 ALLEY 25 SUNIGA DRIVE OLD VINE DRIVE ALLEY 14 RAIN GARDEN (R1) INLET INLETS (2) INLETS (2) SWALE INLETS (2) INLETS (2) INLETS (2) INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET ULTIMATE OUTFALL (TO BE CONSTRUCTED PER WATERFIELD FILING 1 CONSTRUCTION PLANS) C5.00 DRAINAGE EXHIBIT NORTH ( IN FEET ) 0 1 INCH = 150 FEET 150 300 54 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION A 1 1 A LEGEND: PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING CONTOUR PROPOSED CONTOUR DESIGN POINT OVERLAND FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION C5.00 150 450 PROPOSED DIRECT FLOW PROJECT BENCHMARKS: Project Benchmarks: 92-1 - Located along East Vine Dr. at the Pleasant Valley and Lake Canal, on a bridge on the top of the northwest headwall. Elevation = 4946.31 (NAVD88) 2-07 - Located on Vine Drive, 0.1 mile West of Timberline Rd., 50ft North of the entrance to Bull Run Townhomes on the Northwest corner of the West catchbasin. Elevation = 4959.98 (NAVD88) Basis of Bearings The Basis of Bearings is the South line of the Southwest Quarter of Section 5 as bearing South 88°53'23" East (assumed bearing). NOTES: 1. REFER TO THE "PRELIMNARY DRAINAGE REPORT FOR THRIVE DATED SEPTEMBER 5, 2018" BY NORTHERN ENGINEERING FOR ADDITIONAL INFORMATION. Pond ID Vol. (Ac-Ft) 100-Yr WSEL (Ft) WQ Capture Vol. (Ac-Ft) WQ WSEL (Ft) Total Req'd Vol. (Ac-Ft) 100-Yr Release (cfs) Wetland 12.16 TBD 0.48 TBD 12.64 3.20 1 7.46 TBD 0.27 TBD 7.73 7.6 2 4.87 TBD N/A TBD 4.87 13.2 DRAINAGE SUMMARY TABLE DESIGN POINT BASIN ID TOTAL AREA (acres) C2 C100 2-yr Tc (min) 100-yr Tc (min) Q2 (cfs) Q100 (cfs) 1 1 11.64 0.58 0.72 20.2 19.2 10.9 48.5 2 2 3.86 0.58 0.72 18.5 17.6 3.8 16.8 3 3 3.21 0.58 0.72 17.9 16.9 3.2 14.4 4 4 10.68 0.58 0.72 25.5 24.6 8.8 38.9 5 5 15.24 0.58 0.72 20.3 19.6 14.2 62.6 6 6 11.00 0.25 0.31 27.9 25.8 3.7 16.9 7 7 3.45 0.71 0.88 30.2 29.6 3.2 13.9 8 8 14.45 0.51 0.64 24.0 23.1 10.8 47.8 9 9 16.40 0.51 0.64 22.3 21.4 12.8 57.0 OS1 OS1 1.68 0.71 0.88 17.2 16.7 2.1 9.2 OS2 OS2 1.12 0.73 0.91 21.0 20.5 1.3 5.7 FUTURE GROUND ELEVATION (TYP.) CENTERLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 45+00 ! PRELIMINARY ! NOT FOR CONSTRUCTION MATCH LINE STA 45+00 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH C4.27 PLAN & PROFILE TIMBERLINE - ULTIMATE 53 C4.23 C4.24 C4.25 C4.26 C4.27 FUTURE 6' SIDEWALK EXISTING TIMBERLINE ROAD EDGE OF ASPHALT PROPOSED HANDICAP RAMP PROPOSED HANDICAP RAMP TRACT H TRACT K EXISTING EDGE OF ASPHALT EXISTING TIMBERLINE ROAD CENTERLINE ULTIMATE TIMBERLINE ROAD CENTERLINE EXISTING BRIDGE EXISTING BRIDGE ∆ PROPOSED 6' SIDEWALK PROPOSED IRRIGATION LINE FUTURE IRRIGATION EXTENSION STREET D SEE SHEET C4.07 4965 4970 4975 4980 4985 4990 4965 4970 4975 4980 4985 4990 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 3.30% EVCS: 37+18.96 EVCE: 4970.37 1.30% 0.80% 0.90% PVI STA = 44+18.86 PVI ELEV = 4982.89 PVI STA = 42+65.56 PVI ELEV = 4981.22 PVI STA = 43+45.07 PVI ELEV = 4981.93 370.0' VC PVI STA = 39+77.84 PVI ELEV = 4978.92 BVCS: 37+92.84 BVCE: 4972.81 EVCS: 41+62.84 EVCE: 4980.40 A.D. = 2.50 K = 148.00 1.30% FUTURE GRADE FUTURE GRADE EXISTING GROUND EXISTING GROUND EXISTING GROUND ELEVATION (TYP.) PROPOSED GROUND ELEVATION (TYP.) FUTURE GRADE TIE INTO EXISTING BRIDGE 18" IRRIGATION CROSSING w/ ENCASEMENT STA.=39+19.84 INV.= 4970.94 EXISTING GROUND 4965 4970 4975 4980 4985 4990 4965 4970 4975 4980 4985 4990 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 0.90% 3.30% 0.80% 1.30% 1.30% PVI STA = 37+89.87 PVI ELEV = 4971.65 PVI STA = 43+44.60 PVI ELEV = 4980.86 PVI STA = 42+65.09 PVI ELEV = 4980.14 PVI STA = 43+97.74 PVI ELEV = 4981.55 PVI STA = 44+18.39 PVI ELEV = 4981.82 370.0' VC PVI STA = 39+77.37 PVI ELEV = 4977.84 BVCS: 37+92.37 BVCE: 4971.74 EVCS: 41+62.37 EVCE: 4979.32 A.D. = 2.50 K = 148.00 PROPOSED GRADE EXISTING GROUND EXISTING GROUND ELEVATION (TYP.) PROPOSED GROUND ELEVATION (TYP.) 18" IRRIGATION CROSSING w/ ENCASEMENT STA.=39+34.61 INV.= 4970.95 LEFT FLOWLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) CENTERLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 36+00 LINE MATCH STA 45+00 MATCH LINE STA 45+00 MATCH LINE STA 45+00 MATCH LINE STA 36+00 MATCH LINE STA 36+00 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.26 PLAN & PROFILE TIMBERLINE - ULTIMATE 52 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C4.23 C4.24 C4.25 C4.26 C4.27 SUNIGA ROAD SEE SHEET C4.18 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 4995 5000 5005 5010 4945 4950 4955 4960 4965 4970 4975 4980 4985 4990 4995 5000 5005 5010 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 -4.00% EVCS: 27+63.99 EVCE: 4979.37 800.0' VC LOW PT ELEV = 4964.41 LOW PT STA = 33+57.31 PVI STA = 33+18.96 PVI ELEV = 4957.17 BVCS: 29+18.96 BVCE: 4973.17 A.D. = 7.30 K = 109.59 FUTURE GRADE EXISTING GROUND EXISTING GROUND ELEVATION (TYP.) FUTURE GROUND ELEVATION (TYP.) CENTERLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 26+00 LINE MATCH STA 36+00 ! PRELIMINARY ! NOT FOR CONSTRUCTION MATCH LINE STA 36+00 MATCH LINE STA 26+00 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.25 PLAN & PROFILE TIMBERLINE - ULTIMATE 51 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C4.23 C4.24 C4.25 C4.26 C4.27 BVCS: 17+63.99 BVCE: 4975.37 A.D. = 8.80 K = 113.64 FUTURE GRADE EXISTING GROUND EXISTING GROUND ELEVATION (TYP.) FUTURE GROUND ELEVATION (TYP.) HEIGHT @ CL TRACKS 24.4±' CL OF RAIL ROAD TRACKS STA.=22+65.19 CENTERLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 16+50 LINE MATCH STA 26+00 ! PRELIMINARY ! NOT FOR CONSTRUCTION MATCH LINE STA 16+50 MATCH LINE STA 26+00 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.24 PLAN & PROFILE TIMBERLINE - ULTIMATE 50 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C4.23 C4.24 C4.25 C4.26 C4.27 PVI ELEV = 4949.15 FUTURE GRADE EXISTING GROUND EXISTING GROUND ELEVATION (TYP.) FUTURE GROUND ELEVATION (TYP.) (0.83%) 150.0' VC PVI STA = 11+09.73 PVI ELEV = 4950.03 BVCS: 10+34.73 BVCE: 4949.43 EVCS: 11+84.73 EVCE: 4951.68 A.D. = 1.40 K = 107.14 240.0' VC PVI STA = 13+42.86 PVI ELEV = 4955.16 BVCS: 12+22.86 BVCE: 4952.52 EVCS:14+62.86 EVCE:4960.92 A.D. = 2.60 K = 92.31 CENTERLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 16+50 ! PRELIMINARY ! NOT FOR CONSTRUCTION MATCH LINE STA 16+50 NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.23 PLAN & PROFILE TIMBERLINE - ULTIMATE 49 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C4.23 C4.24 C4.25 C4.26 C4.27 OF ASPHALT EXISTING BRIDGE PROPOSED ASPHALT TRANSITION TIE TO EXISTING EXISTING CP TEST STATION TO BE RELOCATED (SEE NOTE 8) PROPOSED 6' SIDEWALK CROSS SECTION A-A PROPOSED ASPHALT WIDENING EXISTING ASPHALT 4965 4970 4975 4980 4985 4990 4965 4970 4975 4980 4985 4990 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 4965 4970 4975 4980 4985 4990 4995 4965 4970 4975 4980 4985 4990 4995 37+00 38+00 39+00 40+00 41+00 42+00 43+00 44+00 45+00 EXISTING GROUND ELEVATION (TYP.) EXISTING GROUND EXISTING GROUND ELEVATION (TYP.) EXISTING GROUND PROPOSED GRADE PROPOSED GRADE ELEVATION (TYP.) CENTERLINE EXISTING TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 37+00 MATCH LINE STA FLOWLINE TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) 37+00 MATCH LINE STA 37+00 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.22 PLAN & PROFILE TIMBERLINE - INTERIM 48 C4.22 C4.21 PROPOSED INTERIM EDGE OF ASPHALT CENTER SECTION LINE EXISTING CP TEST STATION TO BE RELOCATED (SEE NOTE 8) APPROXIMATE LOCATION OF BURIED CP TEST STATION TO BE RELOCATED NOT FIELD LOCATION (SEE NOTE 8) CROSS SECTION A-A PROPOSED ASPHALT WIDENING EXISTING ASPHALT 4945 4950 4955 4960 4965 4970 4975 4980 4945 4950 4955 4960 4965 4970 4975 4980 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00 35+00 36+00 EXISTING GROUND ELEVATION (TYP.) EXISTING GROUND LINE MATCH STA 36+00 CENTERLINE EXISTING TIMBERLINE ROAD SCALE : 1" = 40' (H) 1" = 5' (V) MATCH LINE STA 36+00 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR NORTH CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.21 PLAN & PROFILE TIMBERLINE - INTERIM 47 C4.22 C4.21 CURB AND GUTTER 6' SIDEWALK 6' ASPHALT BIKE PATH FUTURE 30" VERTICAL CURB AND GUTTER 6' SIDEWALK 6' ASPHALT BIKE PATH SUNIGA ROAD FUTURE 18" OUTFALL (MEDIAN) CURB AND GUTTER LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE SUNIGA ROAD SCALE : 1" = 40' (H) 1" = 5' (V) C4.20 PLAN & PROFILE SUNIGA ROAD 44 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 MATCH LINE SEE SHEET C4.19 STA 48+50 LINE MATCH STA 48+50 NORTH 4959.77 4959.92 4960.07 4960.22 4960.37 4960.52 4960.67 4960.82 4960.97 4961.12 4961.27 EXISTING GROUND ∆ SUNIGA ROAD 65'  -  115' ROW 30" VERTICAL CURB AND GUTTER 6' SIDEWALK 6' ASPHALT BIKE PATH 30" VERTICAL CURB AND GUTTER 6' SIDEWALK 6' ASPHALT BIKE PATH FUTURE 18" OUTFALL (MEDIAN) CURB AND GUTTER 65'  -  115' ROW 30" VERTICAL CURB AND GUTTER 6' SIDEWALK 6' ASPHALT BIKE PATH ∆ 6' SIDEWALK 6' ASPHALT BIKE PATH 30" VERTICAL CURB AND GUTTER SUNIGA ROAD FUTURE 18" OUTFALL (MEDIAN) CURB AND GUTTER LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE SUNIGA ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 38+50 MATCH LINE SEE SHEET C4.20 STA 48+50 C4.19 PLAN & PROFILE SUNIGA ROAD 44 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 MATCH LINE SEE SHEET C4.18 STA 38+50 LINE MATCH STA 48+50 NORTH LINE MATCH STA 43+50 LINE MATCH STA 43+50 NORTH 4959.91 4960.03 4960.16 4960.28 4960.41 4960.53 4960.66 4960.78 4960.91 4961.03 4961.16 4961.28 4961.41 4961.53 4961.66 4961.77 4961.85 4961.88 4961.87 4961.83 4961.73 4961.85 4962.07 4962.29 4962.51 4962.73 4962.95 4963.17 4963.39 4963.79 4964.35 4963.95 4963.51 4963.36 4963.21 FUTURE GRADE PROPOSED GRADE (FOR INTERIM) 155'± INTERIM DESIGN TO BE CONSTRUCTED TIE INTO EXISTING EXISTING TIMBERLINE ROAD EXISTING TIMBERLINE ROAD ℄ IRR IRR IRR IRR STREET A SEE SHEET C4.00 65' -  130' ROW 30" VERTICAL CURB AND GUTTER 6' SIDEWALK 30" VERTICAL CURB AND GUTTER 6' ASPHALT BIKE PATH 6' SIDEWALK 6' ASPHALT BIKE PATH 9' UTILITY EASEMENT SUNIGA ROAD PROPOSED STORM DRAIN IRRIGATION LINE TIMBERLINE SEE SHEET C4.25 TIMBERLINE SEE SHEET C4.25 19'  - MEDIAN 7'  -  MEDIAN 18" OUTFALL (MEDIAN) CURB AND GUTTER LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE SUNIGA ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 28+50 MATCH LINE SEE SHEET C4.19 STA 38+50 C4.18 PLAN & PROFILE SUNIGA ROAD 44 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 MATCH LINE SEE SHEET C4.17 STA 28+50 LINE MATCH STA 38+50 NORTH NORTH 4958.23 4958.36 0.55% STREET E SEE SHEET C4.09 ∆ 65'  -  115' ROW 30" VERTICAL CURB AND GUTTER 6' SIDEWALK 30" VERTICAL CURB AND GUTTER 6' ASPHALT BIKE PATH 9' UTILITY EASEMENT 6' SIDEWALK 6' ASPHALT BIKE PATH 9' UTILITY EASEMENT STREET E SEE SHEET C4.09 10' PAN SUNIGA ROAD 7'  -  MEDIAN 18" OUTFALL (MEDIAN) CURB AND GUTTER 6' SIDEWALK 6' ASPHALT BIKE PATH 6' SIDEWALK 6' ASPHALT BIKE PATH 9' UTILITY EASEMENT SUNIGA ROAD 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER 65'  - 130' ROW 7'  - MEDIAN 18" OUTFALL (MEDIAN) CURB AND GUTTER LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE SUNIGA ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 18+50 MATCH LINE SEE SHEET C4.18 STA 28+50 C4.17 PLAN & PROFILE SUNIGA ROAD 43 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH MATCH LINE SEE SHEET C4.16 STA 18+50 LINE MATCH STA 25+50 LINE MATCH STA 25+50 LINE MATCH STA 28+50 NORTH A.D. = 1.20 K = 125.00 150.0' VC LP ELEV = 4953.08 LP STA = 18+28.26 PVI STA = 18+25.00 PVI ELEV = 4952.86 BCVS: 17+50 BVCE: 4953.32 A.D. = 1.15 K = 130.43 1.40% 1.00% PVI STA = 10+06.12 PVI ELEV = 4953.12 PVI STA = 10+53.14 PVI ELEV = 4953.59 STORM DRAIN MH STORM DRAIN MH STORM DRAIN MH 4952.68 4953.03 4953.30 4953.4952.55 80 4953.72 4953.86 4953.96 4954.01 4954.03 4954.00 4953.94 4953.83 4953.68 4953.53 4953.41 4953.33 4953.31 4953.33 4953.41 4953.53 4953.68 4953.83 4953.94 4954.01 4954.04 4954.03 4953.98 4953.89 4953.76 4953.62 4953.46 4953.32 4953.19 4953.11 4953.08 UD UD UD UD UD X X X X X G G G G G 30" VERTICAL CURB AND GUTTER 65'  -  115' ROW STREET H SEE SHEET C4.13 STREET G SEE SHEET C4.12 6' SIDEWALK 30" VERTICAL CURB AND GUTTER ∆ 6' ASPHALT BIKE PATH 6' SIDEWALK 6' ASPHALT BIKE PATH 10' PAN 10' PAN 9' UTILITY EASEMENT BUS STOP BUS STOP BIO-SWALE SUNIGA ROAD PROPOSED TYPE III BARRICADES PROPOSED TYPE III BARRICADES PROPOSED STORM DRAIN 19' - MEDIAN 18" OUTFALL (MEDIAN) CURB AND GUTTER LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE SUNIGA ROADVE SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 9+50 MATCH LINE SEE SHEET C4.17 STA 18+50 C4.16 PLAN & PROFILE SUNIGA ROADVE 42 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH MATCH LINE SEE SHEET C4.15 STA 9+50 LINE MATCH STA 18+50 4950.19 4950.05 4949.90 4949.75 4949.60 4949.45 4949.31 4949.19 4949.13 4949.12 4949.17 4949.28 4949.43 4949.64 4949.91 4950.23 4950.58 4950.93 4951.28 4951.63 4951.98 EXISTING GROUND ∆ FUTURE 30" VERTICAL CURB AND GUTTER FUTURE 30" VERTICAL CURB AND GUTTER 65' - 115' ROW 6' SIDEWALK 6' SIDEWALK 6' ASPHALT BIKE PATH 6' ASPHALT BIKE PATH SUNIGA ROAD 19' - MEDIAN FUTURE 18" OUTFALL (MEDIAN) CURB AND GUTTER FUTURE 30" VERTICAL CURB AND GUTTER FUTURE 30" VERTICAL CURB AND GUTTER ∆ 65'  -  115' ROW 6' SIDEWALK 6' SIDEWALK 6' ASPHALT BIKE PATH 6' ASPHALT BIKE PATH SUNIGA ROAD FUTURE 18" OUTFALL (MEDIAN) CURB AND GUTTER LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE SUNIGA ROAD SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 4+50 MATCH LINE SEE SHEET C4.16 STA 9+50 C4.15 PLAN & PROFILE SUNIGA ROAD 41 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH LINE MATCH STA 4+50 NORTH C4.15 C4.16 C4.17 C4.18 C4.19 C4.20 GROUND PROPOSED GRADE EXISTING RCP STORM GROUND RCP STORM RCP STORM STREET H STREET H ∆ STREET G SEE SHEET C4.12 STREET E SEE SHEET C4.10 ALLEY 22 ALLEY 21 ALLEY 16 ALLEY 22 STREET G SEE SHEET C4.12 STOP SIGN 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT STREET E SEE SHEET C4.10 36'  -  57' ROW 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER PROPOSED STORM DRAIN LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET H SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 17+50 C4.14 PLAN & PROFILE STREET H 40 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH MATCH LINE SEE SHEET C4.13 STA 17+50 C4.13 C4.14 PVI ELEV = 4952.35 RCP STORM STREET H ∆ SUNIGA ROAD ALLEY 25 SEE SHEET C4.16 ALLEY 15 STOP SIGN 4.5' SIDEWALK 4.5' SIDEWALK SUNIGA ROAD SEE SHEET C4.16 9' UTILITY EASEMENT 9' UTILITY EASEMENT 36'  -  57' ROW 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER PROPOSED STORM DRAIN STREET H ∆ ALLEY 17 ALLEY 18 ALLEY 19 ALLEY 24 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 36'  -  57' ROW 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER PROPOSED STORM DRAIN LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET H SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 17+50 MATCH LINE SEE SHEET C4.14 STA 17+50 C4.13 PLAN & PROFILE STREET H 39 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH LINE MATCH STA 13+50 LINE MATCH STA 13+50 C4.13 C4.14 NORTH -1.10% 0.70% PVI STA = 10+00.00 PVI ELEV = 4953.27 PVI STA = 18+77.18 PVI ELEV = 4949.60 PVI STA = 18+55.18 PVI ELEV = 4949.10 PVI STA = 10+30.50 PVI ELEV = 4952.58 PVI STA = 14+33.00 PVI ELEV = 4948.55 81.0' VC LP ELEV = 4947.33 LP STA = 15+69.12 PVI STA = 15+60.12 PVI ELEV = 4947.16 BCVS: 15+19.62 BVCE: 4947.60 ECVS: 16+00.62 EVCE: 4947.44 A.D. = 1.80 K = 45.00 RCP STORM RCP STORM RCP STORM RCP STORM RCP STORM STREET G STREET H 18'  -  80' ROW STREET H SEE SHEET C4.14 ALLEY 16 ALLEY 16 SUNIGA ROAD SEE SHEET C4.16 STOP SIGN 4.5' SIDEWALK STOP SIGN STOP SIGN STOP SIGN 18'  -  ROW VARIES 20' - 20'  -  4.5' SIDEWALK 4.5' SIDEWALK OLD VINE 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 10' PAN 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER 18" OUTFALL VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER 18" OUTFALL VERTICAL CURB AND GUTTER 18" OUTFALL VERTICAL CURB AND GUTTER STREET H SEE SHEET C4.14 SUNIGA ROAD SEE SHEET C4.16 18'  -  18'  - LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET G SCALE : 1" = 40' (H) 1" = 5' (V) C4.12 PLAN & PROFILE STREET G 19 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.12 NORTH CURB AND GUTTER 30' -  53' ROW STREET B SEE SHEET C4.01 31" DRIVE-OVER CURB AND GUTTER ∆ ∆ ∆ 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT EXISTING 42" DUCTILE IRON PIPE NORTH WELD COUNTY WATER DISTRICT (NWCWD) & ELCO WATER LINE EXISTING 24" DUCTILE IRON PIPE EAST LARIMER COUNTY WATER DISTRICT (ELCO) WATER LINE 20' WATERLINE EASEMENT EAST LARIMER COUNTY WATER DISTRICT 40' EAST LARIMER COUNTY WATER DISTRICT RIGHT OF WAY EASEMENT 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 13+50 14+00 15+00 16+00 17+00 18+00 4968.72 4965.23 4963.44 4961.72 4969.96 4967.61 4966.66 4965.87 4964.75 4964.31 4963.87 4963.00 4962.56 4962.13 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND -5.00% -1.75% 2.25% PVI STA = 16+99.31 PVI ELEV = 4961.70 PVI STA = 17+15.31 PVI ELEV = 4962.06 130.2' VC PVI STA = 14+54.62 PVI ELEV = 4965.97 BCVS: 13+89.53 BVCE: 4969.23 ECVS: 15+19.72 EVCE: 4964.84 A.D. = 3.25 K = 40.00 STREET F STREET E SEE SHEET C4.08 ∆ 4.5' SIDEWALK 4.5' SIDEWALK STOP SIGN 30'  - 53' ROW 8' PAN STREET E SEE SHEET C4.08 9' UTILITY EASEMENT 9' UTILITY EASEMENT LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR LINE MATCH STA 15+50 C4.11 PLAN & PROFILE STREET F 37 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.11 NORTH CENTERLINE STREET F SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 15+50 NORTH 60" RCP STORM 12" RCP STORM ST ST ST ST ST ST D D 30" VERTICAL CURB AND GUTTER 36'  -  4.5' SIDEWALK 4.5' SIDEWALK 30" VERTICAL CURB AND GUTTER STREET H SEE SHEET C4.14 50' - 9' UTILITY EASEMENT EXISTING STORM DRAIN MERGANSER DR. 76' ROW EXISTING 60" RCP LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET E SCALE : 1" = 40' (H) 1" = 5' (V) C4.10 PLAN & PROFILE STREET E 36 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH MATCH LINE SEE SHEET C4.09 STA 27+50 LINE MATCH STA 27+50 C4.08 C4.09 C4.10 120.0' VC HP ELEV = 4959.51 HP STA = 20+32.09 PVI STA = 20+44.09 PVI ELEV = 4959.87 BVCS: 19+84.09 BVCE: 4959.27 EVCS: 21+04.09 EVCE: 4958.97 A.D. = 2.50 K = 48.00 BVCS: 27+07.14 BVCE: 4960.10 ECVS: 18+57.76 EVCE: 4958.00 103.5' VC LP ELEV = 4955.45 LP STA = 23+72.47 PVI STA = 23+56.72 PVI ELEV = 4955.18 BCVS: 23+04.97 BVCE: 4955.95 ECVS: 24+08.47 EVCE: 4955.59 A.D. = 2.30 K = 45.00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND STREET E ∆ ALLEY 9 STREET D SEE SHEET C4.06 ALLEY 8 30" VERTICAL CURB AND GUTTER ALLEY 8 ALLEY 9 30" VERTICAL CURB AND GUTTER 36'  -  57' ROW 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT PROPOSED STORM DRAIN PROPOSED STORM DRAIN SUNIGA RAOD SEE SHEET C4.17 SUNIGA RAOD SEE SHEET C4.17 STREET E 30" VERTICAL CURB AND GUTTER 36' - 4.5' SIDEWALK 4.5' SIDEWALK 30" VERTICAL CURB AND GUTTER 9' UTILITY EASEMENT LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET E SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 24+50 MATCH LINE SEE SHEET C4.10 STA 27+50 C4.09 PLAN & PROFILE STREET E 35 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH MATCH LINE SEE SHEET C4.08 STA 18+50 LINE MATCH STA 18+50 LINE MATCH STA 24+50 LINE MATCH STA 27+50 C4.08 C4.09 C4.10 NORTH 30" VERTICAL CURB AND GUTTER 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT STREET B SEE SHEET C4.01 PROPOSED STORM DRAIN PROPOSED STORM DRAIN 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 13+50 14+00 15+00 16+00 17+00 18+00 18+50 4963.47 4961.87 4960.37 4958.87 4957.77 4964.08 4963.00 4962.62 4962.25 4961.50 4961.12 4960.75 4960.00 4959.62 4959.25 4958.50 4958.14 4957.89 4957.79 -1.50% 135.0' VC PVI STA = 13+62.63 PVI ELEV = 4963.93 ECVS: 14+30.13 EVCE: 4962.92 A.D. = 3.00 K = 45.00 120.0' VC LP ELEV = 4957.76 LP STA = 18+09.76 PVI STA = 17+97.76 PVI ELEV = 4957.40 BCVS: 17+37.76 BVCE: 4958.30 A.D. = 2.50 K = 48.00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND RCP STORM RCP STORM LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET E SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 18+50 MATCH LINE SEE SHEET C4.09 STA 18+50 C4.08 PLAN & PROFILE STREET E 34 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH C4.08 C4.09 C4.10 AND GUTTER 36' - 60' ROW 4.5' SIDEWALK STOP SIGN 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' PAN 18" OUTFALL VERTICAL CURB AND GUTTER STREET C SEE SHEET C4.05 PROPOSED STORM DRAIN IRRIGATION LINE LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET D SCALE : 1" = 40' (H) 1" = 5' (V) C4.07 PLAN & PROFILE STREET D 33 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 LINE MATCH STA 18+50 NORTH C4.06 C4.07 MATCH LINE SEE SHEET C4.06 STA 18+50 PVI ELEV = 4971.58 BVCS: 16+97.36 BVCE: 4970.95 EVCS: 17+87.36 EVCE: 4971.85 A.D. = 0.80 K = 112.50 90.0' VC PVI STA = 12+80.33 PVI ELEV = 4965.11 BVCS: 12+35.33 BVCE: 4964.03 EVCS: 13+25.33 EVCE: 4965.74 A.D. = 1.00 K = 90.00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND STREET D STREET B SEE SHEET C4.02 STREET E SEE SHEET C4.09 18'  -  80' ROW 18'  -  30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER 4.5' SIDEWALK 4.5' SIDEWALK STOP SIGN 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' PAN 8' PAN STREET E SEE SHEET C4.09 STREET B SEE SHEET C4.02 18" OUTFALL VERTICAL CURB AND GUTTER ∆ 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER ROW VARIES 20'  - 20'   -  4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 18" OUTFALL VERTICAL CURB AND GUTTER LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET D SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 15+50 MATCH LINE SEE SHEET C4.07 STA 18+50 C4.06 PLAN & PROFILE STREET D 32 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 NORTH LINE MATCH STA 15+50 LINE MATCH STA 18+50 NORTH C4.06 C4.07 4.5' SIDEWALK 4.5' SIDEWALK 9 UTILITY EASEMENT 9 UTILITY EASEMENT STREET D SEE SHEET C4.07 ∆ 4950 4955 4960 4965 4970 4975 4950 4955 4960 4965 4970 4975 21+50 22+00 23+00 24+00 25+00 26+00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND 4970.97 4966.01 4962.47 4960.95 4972.22 4969.72 4968.47 4967.22 4964.93 4963.98 4963.16 4961.92 4961.49 4961.20 4960.70 4960.45 -1.00% -2.25% -5.00% PVI STA = 25+55.70 PVI ELEV = 4960.39 PVI STA = 21+57.12 PVI ELEV = 4973.12 190.0' VC PVI STA = 23+75.64 PVI ELEV = 4962.19 BCVS: 22+80.64 BVCE: 4966.94 ECVS: 24+70.64 EVCE: 4961.24 A.D. = 4.00 K = 47.50 ALLEY 5 PROPOSED STORM DRAIN KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C4.05 OVERALL GRADING PLAN STREET C NORTH 19 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER CENTERLINE STREET C SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 18+50 ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 MATCH LINE SEE SHEET C4.04 STA 18+50 NORTH LINE MATCH STA 25+00 LINE MATCH STA 25+00 C4.04 C4.05 SEE SHEET C4.02 ALLEY 11 ∆ ALLEY 10 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 4970 4975 4980 4985 4990 4995 4970 4975 4980 4985 4990 4995 15+00 16+00 17+00 18+00 18+50 4978.56 4980.35 4980.95 4977.21 4977.66 4978.11 4979.01 4979.46 4979.91 4980.69 4980.90 4980.99 4980.78 1.80% 240.0' VC HP ELEV = 4980.99 HP STA = 17+79.73 PVI STA = 18+09.73 PVI ELEV = 4982.34 BVCS: 16+89.73 BVCE: 4980.18 A.D. = 4.80 K = 50.00 PROPOSED GRADE EXISTING GROUND KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C4.04 OVERALL GRADING PLAN STREET C NORTH 19 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER CENTERLINE STREET C SCALE : 1" = 40' (H) 1" = 5' (V) LINE MATCH STA 18+50 MATCH LINE SEE SHEET C4.05 STA 18+50 ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.04 C4.05 GRADE EXISTING GROUND RCP STORM IRR IRR IRR IRR IRR STREET B ALLEY 4 ALLEY 1 ALLEY 7 STREET A SEE SHEET C4.00 ALLEY 6 ALLEY 3 ALLEY 5 STREET C SEE SHEET C4.05 36' -  57' ROW 30" VERTICAL CURB AND GUTTER 30" VERTICAL CURB AND GUTTER 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C4.03 PLAN & PROFILE STREET B 19 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 LINE MATCH STA 25+50 CENTERLINE STREET B SCALE : 1" = 40' (H) 1" = 5' (V) NORTH MATCH LINE SEE SHEET C4.02 STA 24+50 C4.02 C4.03 C4.01 HP ELEV = 4968.48 HP STA = 19+19.68 PVI STA = 19+51.18 PVI ELEV = 4968.75 BVCS: 18+92.68 BVCE: 4968.40 EVCS: 20+09.68 EVCE: 4967.58 A.D. = 2.60 K = 45.00 207.0' VC LP ELEV = 4967.88 LP STA = 17+92.32 PVI STA = 17+15.82 PVI ELEV = 4967.34 ECVS: 18+19.32 EVCE: 4967.96 A.D. = 4.60 K = 45.00 PROPOSED GRADE EXISTING GROUND PROPOSED GRADE EXISTING GROUND RCP STORM STREET B ALLEY 13 36'  -  57' ROW ALLEY 12 ALLEY 9 STREET C SEE SHEET C4.04 STREET D SEE SHEET C4.06 ALLEY 8 ∆ ∆ ALLEY 9 STREET D SEE SHEET C4.05 ALLEY 8 36'  -  57' ROW 30" VERTICAL CURB AND GUTTER STOP SIGN 4.5' SIDEWALK 4.5' SIDEWALK 30" VERTICAL CURB AND GUTTER LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR MATCH LINE SEE SHEET C4.03 STA 25+50 C4.02 PLAN & PROFILE STREET B 19 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 LINE MATCH STA 16+50 CENTERLINE STREET B SCALE : 1" = 40' (H) 1" = 5' (V) NORTH MATCH LINE SEE SHEET C4.01 STA 16+50 LINE MATCH STA 25+50 C4.02 C4.03 C4.01 BCVS: 16+12.32 BVCE: 4971.48 WV H2O H2O H2O WV W W W W W W W W W W W W W W W W W W W W W W W W W W STREET B 30" VERTICAL CURB AND GUTTER 36' - 57' ROW STREET E SEE SHEET ---- 4.5' SIDEWALK 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT EXISTING 42" DUCTILE IRON PIPE NORTH WELD COUNTY WATER DISTRICT (NWCWD) & ELCO WATER LINE EXISTING 24" DUCTILE IRON PIPE EAST LARIMER COUNTY WATER DISTRICT (ELCO) WATER LINE 20' WATERLINE EASEMENT 40' WATER DISTRICT RIGHT OF WAY EASEMENT EXISITNG CITY OF FORT COLLINS WATER LINE 30" VERTICAL CURB AND GUTTER ∆ 36'  -  57' ROW 30" VERTICAL CURB AND GUTTER 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 30" VERTICAL CURB AND GUTTER STREET B LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR LINE MATCH STA 13+50 MATCH LINE SEE SHEET C4.02 STA 16+50 C4.01 PLAN & PROFILE STREET B 19 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 LINE MATCH STA 13+50 LINE MATCH STA 16+50 CENTERLINE STREET B SCALE : 1" = 40' (H) 1" = 5' (V) NORTH NORTH C4.02 C4.03 C4.01 51' ROW 30" VERTICAL CURB AND GUTTER STREET B SEE SHEET C4.03 STREET B SEE SHEET C4.03 30" VERTICAL CURB AND GUTTER STOP SIGN 4.5' SIDEWALK 4.5' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT SUNIGA ROAD SEE SHEET C4.18 SUNIGA ROAD SEE SHEET C4.18 PROPOSED STORM DRAIN LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. SEE SOILS REPORT FOR PAVEMENT AND SUBGRADE PREPARATION, DESIGN AND RECOMMENDATIONS. 3. MANHOLE RIM ELEVATIONS ARE TO BE ADJUSTED TO 1/4" BELOW FINISHED GRADE. IF NECESSARY, CONE SECTIONS SHALL BE ROTATED TO PREVENT LIDS BEING LOCATED WITHIN VEHICLE OR BICYCLE WHEEL PATHS. 4. EXPANSION JOINTS SHALL BE PROVIDED IN ALL SIDEWALKS AT MAXIMUM SPACING OF 50 FEET. 5. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 6. CONTRACTOR SHALL ADJUST EXISTING SANITARY SEWER MANHOLES AND CLEANOUTS WITHIN THE RIGHT-OF-WAY PER CITY STANDARDS. 7. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 8. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 9. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE INTERIM EDGE OF ASPHALT SAWCUT LINE PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) EXISTING EASEMENT EXISTING EDGE OF ASPHALT FUTURE RIGHT OF WAY FUTURE CENTERLINE FUTURE CURB & GUTTER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR CENTERLINE STREET A SCALE : 1" = 40' (H) 1" = 5' (V) C4.00 PLAN & PROFILE STREET A NORTH 19 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ( IN FEET ) 0 1 INCH = 40 FEET 40 40 80 120 C4.00 51.73 51.73 50.57 49.83 49.68 48.59 48.77 48.77 47.57 47.97 48.52 48.77 49.58 49.66 48.87 49.11 49.31 49.51 50.54 52.45 52.66 53.96 54.40 54.75 54.61 55.87 56.15 56.35 57.65 58.13 58.13 58.43 59.59 58.22 53.98 51.89 52.91 60.04 53.56 58.78 54.31 59.18 TRACT OO 36'  - 115' ROW 65'  -  20' ROW 20' -  56' - 16' 20' 20' 20' 20' 50'  - BULL RUN LTD PARTNERSHIP 5575 DTC PKWY STE 250 GREENWOOD VILLAGE, CO 80111 DIVISION SEVEN SYSTEMS 8 GIBBS RD LARAMIE, WY 80207 OPPIE VERA N PO BOX 302 LAPORTE, CO 80535 OLD VINE DRIVE MERGANSER MERGANSER DR. STREET G STREET G STREET H STREET H ALLEY 16 ALLEY 16 ALLEY 20 ALLEY 21 ALLEY 16 ALLEY 22 ALLEY 23 SUNIGA ROAD SUNIGA ROAD STORM DRAIN EXISTING STORM DRAIN 76' ROW STORM DRAIN INLET INLET 60" HDPE FES INLET INLET TO CONNECT TO EXISTING MH FES 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 18'  -  18'  -  5' SIDEWALK Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C3.06 GRADING PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 25 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 36.25 (36.25) PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C3.05 MATCHLINE-SEE SHEET C3.03 MATCHLINE-SEE SHEET C3.04 MATCHLINE-SEE SHEET C3.03 C3.01 C3.02 C3.03 C3.04 C3.05 C3.06 52.96 53.33 52.43 52.45 52.02 51.95 52.07 50.92 51.93 51.52 51.86 51.79 51.48 52.05 52.00 50.05 50.00 49.66 49.97 49.97 49.39 49.05 49.00 48.66 49.01 50.42 50.48 50.91 51.28 51.49 50.88 50.82 50.26 50.72 48.48 47.69 50.86 50.37 50.26 49.67 48.98 47.66 47.33 49.05 49.00 47.33 47.39 47.40 48.05 47.99 46.98 47.04 47.35 49.01 48.39 48.05 47.99 49.80 49.74 50.21 50.42 49.24 49.31 47.57 47.94 48.02 47.42 47.78 48.20 48.44 48.54 48.77 49.10 49.20 49.25 49.30 47.36 47.04 47.00 51.60 49.68 49.68 48.59 48.77 48.77 47.57 47.97 48.52 48.77 49.58 49.66 48.87 49.11 49.31 49.51 50.54 52.45 51.89 52.91 51.01 52.99 52.50 52.68 51.17 48.68 48.61 57' ROW 36' - 20' -  65'  - 20' 16' 16' 16' 20' 20'  -  56' - 16' 20' 20' 20' WEISS DONALD D/ BEVERLY A 1924 E. VINE DR. FORT COLLINS, CO 80524 CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 STREET G STREET G STREET H STREET H ALLEY 15 ALLEY 15 ALLEY 16 ALLEY 16 ALLEY 17 ALLEY 18 ALLEY 19 ALLEY 20 ALLEY 22 ALLEY 23 ALLEY 24 ALLEY 25 STORM DRAIN STORM DRAIN STORM DRAIN SUNIGA ROAD 115' ROW EXISTING STORM DRAIN (TO BE CONSTRUCTED PER WATERFIELD 1ST FILING PLANS) OVERFLOW OUTFALL STORM DRAIN STORM DRAIN BIO-SWALE W/ UNDERDAIN INLET STORM DRAIN STORM MH (TYP.) INLET INLET INLET INLET (2) FES FES INLET INLET ULTIMATE OUTFALL LOCATION FES 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 20' 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 51.52 51.89 47.30 18'  -  18'  -  5' SIDEWALK 6' SIDEWALK Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C3.05 GRADING PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 24 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 36.25 (36.25) PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C3.03 MATCHLINE-SEE SHEET C3.06 C3.01 C3.02 C3.03 C3.04 C3.05 C3.06 64.16 64.52 65.03 65.28 65.55 54.94 59.18 61.30 56.68 57.08 56.96 61.26 57.27 61.28 61.52 57.91 69.53 58.63 59.76 62.32 59.76 59.76 61.98 63.52 64.44 64.29 63.32 63.48 65.55 67.17 60.36 60.47 61.71 60.91 59.63 59.55 60.13 60.36 58.97 59.15 60.70 60.30 59.33 58.97 61.22 61.48 74.45 73.57 73.12 65.41 64.68 64.25 67.85 68.32 68.07 68.33 61.89 61.61 68.68 63.62 63.57 63.44 63.17 65.91 67.07 70.12 69.33 68.88 63.73 63.63 64.25 63.84 57.52 63.84 64.68 TRACT OO 65.67 72.12 71.78 73.12 73.07 73.13 72.50 72.82 71.63 68.98 67.32 65.25 71.78 73.57 74.45 65.91 65.37 64.56 64.29 62.82 63.03 60.92 61.03 61.67 61.86 62.45 62.25 62.17 64.56 64.99 61.20 60.92 62.25 62.20 57' ROW 36'  - 16' 16' 16' 16' 20' 18'  - 18'  - 80' ROW 57' ROW 36' -  20' 36' - 51' ROW 30'  - 57' ROW 36' -  20' 65' -  BULL RUN LTD PARTNERSHIP 5575 DTC PKWY STE 250 GREENWOOD VILLAGE, CO 80111 OPPIE VERA N PO BOX 302 LAPORTE, CO 80535 MERGANSER DR. STREET A STREET C STREET C STREET D STREET D STREET E ALLEY 2 ALLEY 1 ALLEY 3 ALLEY 4 ALLEY 4 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 5 ALLEY 6 ALLEY 7 STORM DRAIN SUNIGA ROAD INLET INLET FES SWALE FES FES STORM DRAIN INLET INLET INLET 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 62.43 63.47 60.23 SWALE 20' - 20' - 18' - Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C3.04 GRADING PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 23 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 36.25 (36.25) PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C3.06 MATCHLINE-SEE SHEET C3.02 MATCHLINE-SEE SHEET C3.03 C3.01 C3.02 C3.03 C3.04 C3.05 C3.06 52.34 52.33 52.57 52.69 52.10 52.22 51.95 51.83 52.16 52.04 52.15 52.03 51.71 51.83 51.34 51.46 51.47 51.59 51.29 51.41 51.41 51.53 51.13 51.25 51.63 51.75 51.70 55.66 54.34 55.64 55.75 57.83 56.11 55.92 56.11 56.29 59.00 57.98 56.58 56.55 52.10 58.21 56.80 56.07 55.99 52.58 51.33 55.10 55.08 52.46 51.21 51.48 51.01 50.89 50.46 51.39 50.45 50.48 53.05 53.17 52.65 55.00 55.78 54.36 53.69 51.12 51.01 50.95 50.88 50.79 50.70 55.32 55.29 56.61 58.98 53.36 52.91 53.19 51.75 58.65 58.19 59.11 51.77 51.41 53.30 53.34 57.12 60.41 60.44 61.80 61.53 58.42 55.43 63.73 63.34 62.78 61.80 52.60 68.31 68.29 69.07 69.68 69.79 69.68 70.09 68.29 67.88 67.08 66.79 67.76 65.41 64.68 63.73 63.63 64.25 63.84 57.70 57.52 59.20 59.59 63.84 64.68 66.79 67.08 68.06 57.62 58.01 58.26 57.79 58.54 68.32 65.90 63.25 62.61 62.19 62.98 60.59 58.91 61.42 58.91 65.89 68.07 70.09 69.95 69.13 66.36 66.79 67.17 67.69 67.76 67.39 67.94 65.67 58.37 58.26 59.08 59.59 53.35 55.73 55.55 55.55 55.36 56.92 54.71 57' ROW 36'  -  16' 16' 57' ROW 36'  -  20' 16' 20' 20' 20' 57' ROW 36'  -  36' -  115' ROW 65'  -  20' ROW CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 MERGANSER DR. STREET B STREET D STREET E STREET E ALLEY 8 ALLEY 8 ALLEY 9 ALLEY 12 STREET G ALLEY 16 ALLEY 22 ALLEY 23 ALLEY 24 STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN SUNIGA ROAD FES STORM DRAIN STORM DRAIN STORM DRAIN STORM DRAIN INLET (2) HEADWALL WITH TRASH RACK FES INLET INLET FES INLET INLET FES SWALE POND OUTFALL FES OVERFLOW OUTFALL STORM DRAIN STORM DRAIN BIO-SWALE W/ UNDERDAIN INLET STORM DRAIN STORM MH (TYP.) FES FES 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT HEADWALL WITH TRASH RACK HEADWALL WITH TRASH RACK FES FOREBAY 3 FOREBAY 2 FOREBAY 1 Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C3.03 GRADING PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 22 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 36.25 (36.25) PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C3.05 MATCHLINE-SEE SHEET C3.02 MATCHLINE-SEE SHEET C3.01 MATCHLINE-SEE SHEET C3.06 MATCHLINE-SEE SHEET C3.04 C3.01 C3.02 C3.03 C3.04 C3.05 C3.06 61.22 61.48 74.45 76.19 73.42 73.57 76.55 76.75 79.04 79.23 80.09 79.71 79.49 81.15 81.65 80.09 80.42 78.48 80.08 77.58 76.51 76.95 71.62 70.71 72.94 68.82 67.74 68.31 68.29 69.07 69.68 69.45 69.79 69.68 69.45 69.00 70.09 71.56 71.62 80.99 80.80 80.41 80.38 79.43 77.19 76.81 76.51 77.66 76.69 78.35 76.93 77.33 68.29 67.88 67.08 66.79 67.76 68.82 73.42 73.12 73.36 73.32 72.50 71.70 72.32 72.14 71.97 71.63 71.07 70.68 70.07 69.72 68.99 67.32 65.41 64.68 64.25 67.85 68.32 68.07 68.33 61.89 61.61 68.68 63.62 63.57 63.44 63.17 65.91 67.07 70.12 69.33 68.88 63.73 63.63 64.25 63.84 57.70 57.52 63.84 64.68 66.79 67.08 68.06 68.32 72.31 74.39 73.50 73.22 71.26 70.21 69.16 67.81 67.54 68.94 65.89 68.07 68.95 70.02 71.28 72.67 74.04 72.86 75.86 71.77 70.68 72.59 73.42 74.23 75.05 75.87 76.66 77.58 78.48 79.40 80.22 81.03 80.93 80.51 80.07 80.15 80.51 80.93 81.03 80.21 79.40 76.67 75.85 75.03 74.22 73.40 72.58 72.06 71.23 71.02 71.69 72.43 73.16 73.90 74.63 75.37 76.09 76.92 77.73 78.57 79.31 80.04 80.60 80.82 81.86 81.99 81.77 81.26 80.39 79.72 79.19 78.56 77.86 75.81 75.26 74.39 80.02 78.68 80.68 80.82 80.60 80.04 79.31 78.57 77.73 76.92 76.11 75.37 74.63 73.90 73.01 72.20 71.24 70.09 69.95 69.13 66.36 66.79 67.17 67.69 67.76 68.24 68.79 68.82 69.42 69.87 70.33 70.78 71.24 71.56 71.82 72.04 72.39 72.97 73.30 73.56 73.78 74.13 74.58 75.04 75.49 75.95 76.41 76.93 76.25 67.39 67.94 68.46 68.96 69.54 70.18 70.72 71.25 71.78 72.37 72.96 73.56 74.09 74.63 75.16 75.69 76.28 66.64 66.35 66.01 65.67 67.08 67.52 68.01 68.50 70.38 72.05 71.91 72.12 72.23 72.44 76.62 76.60 77.19 77.79 78.20 78.59 79.43 79.64 71.78 73.12 73.07 73.13 72.50 72.82 71.63 68.98 67.32 65.25 71.78 73.57 74.45 65.91 65.37 64.56 64.29 62.82 63.03 60.92 61.03 61.67 61.86 62.45 62.25 62.17 64.56 64.99 61.20 60.92 62.25 62.20 59.59 57' ROW 36' -  57' ROW 36'  -  16' 16' 57' ROW 36'  -  57' ROW 36'  - 16' 16' 16' 16' 20' 16' 20' 18'  - 18' - 80' ROW 57' ROW 36'  -  16' 20' K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 TIMBERLINE ROAD STREET B STREET C STREET C STREET C STREET D STREET D ALLEY 4 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 5 ALLEY 6 ALLEY 7 ALLEY 9 ALLEY 9 ALLEY 10 ALLEY 10 ALLEY 11 ALLEY 13 STORM DRAIN STORM DRAIN STORM DRAIN INLET FES FES INLET INLET INLET 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 62.43 63.47 71.01 20' - 20' - 18' - 8' SIDEWALK 5' SIDEWALK 5' SIDEWALK Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C3.02 GRADING PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 21 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 36.25 (36.25) PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) MATCHLINE-SEE SHEET C3.04 MATCHLINE-SEE SHEET C3.03 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C3.01 C3.01 C3.02 C3.03 C3.04 C3.05 C3.06 64.86 75.14 73.09 63.38 61.78 71.04 68.99 60.35 58.95 67.17 66.30 66.04 64.91 57.93 56.40 64.34 63.83 53.10 53.84 63.54 63.41 56.85 56.74 55.53 56.04 57.12 60.70 58.57 55.29 58.00 58.98 58.00 52.80 58.94 57.84 57.64 53.15 52.78 53.78 53.08 54.08 53.35 53.41 55.05 54.05 55.05 54.05 54.14 53.14 53.53 52.53 52.28 52.98 52.99 52.98 52.34 52.33 (52.30) (52.21) 52.57 52.69 70.71 72.94 68.82 67.74 68.31 68.29 69.07 69.68 69.45 69.79 69.68 69.45 69.00 70.09 68.29 67.88 67.08 66.79 67.76 66.79 67.08 68.06 57.79 58.54 68.32 65.90 67.05 63.25 62.61 62.19 62.98 60.59 58.91 62.11 62.34 63.53 63.76 65.58 63.11 65.02 65.87 65.73 67.63 68.95 72.78 78.08 78.04 69.82 71.01 72.40 74.99 76.70 79.36 78.40 78.13 77.05 75.72 76.29 74.31 72.90 71.49 70.08 68.67 67.26 72.31 74.39 73.50 73.22 71.26 70.21 69.16 67.81 67.54 68.94 TRACT O 76.29 73.92 72.51 70.08 68.67 67.26 65.87 63.47 63.11 64.32 65.52 66.99 68.56 70.14 71.71 73.29 75.34 76.45 66.74 64.78 65.09 63.4653.47 62.91 62.67 61.88 61.42 58.91 65.89 68.07 68.95 70.02 71.28 72.67 74.04 72.86 75.86 65.95 67.42 69.31 71.36 73.41 75.46 77.51 79.37 80.68 81.50 70.68 71.02 70.09 69.95 69.13 66.36 66.79 67.17 67.69 67.76 67.39 67.94 53.35 53' ROW 30'  -  57' ROW 36' -  57' ROW 36'  -  57' ROW 36'  -  16' ROW 16' 16' 16' 16' 20' 57' ROW 36'  -  PARKER LAND INVESTMENTS LLC 9162 KENWOOD CT HIGHLANDS RANCH, CO 801263425 POUDRE SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 STREET B STREET B STREET E STREET F STREET F ALLEY 12 ALLEY 13 ALLEY 13 STORM DRAIN STORM DRAIN STORM DRAIN FES STORM DRAIN STORM DRAIN INLET (2) STORM DRAIN INLET (2) INLET HEADWALL WITH TRASH RACK FES 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT FOREBAY 1 8' SIDEWALK Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C3.01 GRADING PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 MATCHLINE-SEE SHEET C3.03 MATCHLINE-SEE SHEET C3.02 20 LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 36.25 (36.25) PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R C3.01 C3.02 C3.03 C3.04 C3.05 C3.06 W VAULT ELEC V.P. WV VAULT ELEC WV WV WV V.P. ELEC ELEC E GAS T VAULT ELEC VAULT C ELEC SS SS SS SS SS SS E TH TH TH TH TH TH TH TH TH TH TH TH TH TH TH X X X X X X X X X X X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE H Y D G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W TELE W GAS TELE R R H2O WV WV WV H2O WV WV WV S W SS W W IRR IRR W W W W W W W W W W W W H 2O GAS GAS H2O IRR D D D W W W W W W W W W W W W W W W W W W W W W W W W W W W W BULL RUN APARTMENTS K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 PARKER LAND INVESTMENTS LLC 9162 KENWOOD CT HIGHLANDS RANCH, CO 801263425 WEISS DONALD D/ BEVERLY A 1924 E. VINE DR. FORT COLLINS, CO 80524 POUDRE SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 BULL RUN LTD PARTNERSHIP 5575 DTC PKWY STE 250 GREENWOOD VILLAGE, CO 80111 DIVISION SEVEN SYSTEMS 8 GIBBS RD LARAMIE, WY 80207 OPPIE VERA N PO BOX 302 LAPORTE, CO 80535 K AND M COMPANY PO BOX 449 WEISS DONALD D/ BEVERLY A FORT COLLINS, CO 80522 1924 E. VINE DR. FORT COLLINS, CO 80524 K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 TIMBERVINE FARM LIMITED PARTNERSHIP PO BOX 272546 FORT COLLINS, CO 80527 VOICE OF TRUTH TABERNACLE 1132 SAWTOOTH OAK CT FORT COLLINS, CO 80525 RYK JOE 1506 GLEN HAVEN DR. FORT COLLINS, CO 80526 HOLTER GEORGE A 3509 S MASON ST FORT COLLINS, CO 80525 PLOOG BARRY L PO BOX 967 BOULDER, CO 80306 JONES LEONARD L & ROMA K 2616 E. VINE DR FORT COLLINS, CO 80524 MARK WHITE 132 JENNINGS LN JOHNSTOWN, CO 80534 UD IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR N YLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED PROPOSED STORM DRAIN STORM DRAIN OLD VINE DRIVE TRACT O PROPOSED STORM DRAIN STREET A STREET B STREET B STREET C STREET C STREET D STREET D STREET E STREET E STREET E STREET F STREET F ALLEY 2 ALLEY 1 ALLEY 3 ALLEY 4 ALLEY 4 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 5 ALLEY 6 ALLEY 7 ALLEY 9 ALLEY 9 ALLEY 9 ALLEY 12 ALLEY 10 ALLEY 10 ALLEY 11 ALLEY 13 ALLEY 13 STREET G STREET G STREET H STREET H STREET H ALLEY 15 ALLEY 15 ALLEY 16 ALLEY 16 ALLEY 16 ALLEY 16 ALLEY 17 ALLEY 18 ALLEY 19 ALLEY 20 ALLEY 21 ALLEY 16 ALLEY 22 ALLEY 23 ALLEY 24 ALLEY 25 SUNIGA ROAD N TIMBERLINE ROAD FUTURE REALIGNED N TIMBERLINE ROAD FOREBAY 3 FOREBAY 2 FOREBAY 1 Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C3.00 OVERALL GRADING PLAN NORTH ( IN FEET ) 0 1 INCH = 150 FEET 150 150 300 450 19 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: ST 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED. 4. THE TOP OF FOUNDATION ELEVATIONS SHOWN ARE THE MINIMUM ELEVATIONS REQUIRED FOR PROTECTION FROM THE 100-YEAR STORM. 5. CROSSPANS ALONG PUBLIC STREETS AT THE INTERSECTION OF PRIVATE DRIVES SHALL HAVE CONCRETE EXTENDED TO THE RIGHT-OF-WAY LINE. 6. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM; NAVD 88 (UNADJUSTED). SEE COVER SHEET FOR BENCHMARK REFERENCES. 7. THE NATURAL HABITAT BUFFER ZONE IS INTENDED TO BE MAINTAINED IN A NATIVE LANDSCAPE. PLEASE SEE SECTION 3.4.1 OF THE LAND USE CODE FOR ALLOWABLE USES WITHIN THE NATURAL HABITAT BUFFER ZONE. 36.25 (36.25) PROPOSED SLOPES 2.0% EXISTING SPOT ELEVATION PROPOSED SPOT ELEVATION PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY PROPOSED CURB AND GUTTER PROPOSED SWALE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER EXISTING STORM SEWER LIMITS OF DEVELOPMENT LOD PROPOSED RIGHT OF WAY NATURAL HABITAT BUFFER ZONE (NHBZ) NOTES: PEDESTRIAN ACCESS RAMP PROPOSED CONCRETE CROSS PAN (TYP.) C3.01 C3.02 C3.03 C3.04 C3.05 C3.06 SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS H Y D W W W W W W W W W W W W W W W GAS WV WV WV S W SS SS SS W W W W W W W W W 8" PVC WATER 8" PVC WATER 8" PVC WATER 54.39 LF 8" PVC R=300.00' 8" PVC WATER 8" PVC WATER & 3-8" GV (E,W,S) 8''x8'' TEE w/TB & 3-8" GV (N,E,W) N:134991.74 E:206315.78 8''x8'' TEE w/TB N:134990.68 E:206309.57 8''x8'' TEE w/TB & 1-8" GV (N,E) N:135117.72 E:206294.36 CAP w/TB N:135189.83 E:206282.09 8''x8'' TEE w/TB & 2-8" GV (N,E) N:134676.02 E:206296.69 8''x8'' TEE w/TB & 2-8" GV (N,E) N:134673.54 E:206489.57 8''x8'' TEE w/TB & 2-8" GV (E,N) N:135020.93 E:206487.41 8''x8'' TEE w/TB & 2-8" GV (N,S) N:135018.43 E:206665.76 8''x6" SWIVEL TEE w/TB & 6" GV N:135018.19 E:206684.26 90° BEND w/TB N:135180.65 E:206662.45 CONNECT TO EXISTING 12" ELCO WATER MAIN N:135016.66 E:206803.03 CONNNECT TO EXISTING 12" ELCO WATER MAIN N:135017.49 E:206803.71 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT SSMH A2-6 INV. OUT=4947.40 (S) FG=4958.50 SSMH A2-1.5 INV. OUT=4947.23 (W) FG=4959.10 SSMH A2-5 INV. IN=4945.79 (N) INV. OUT=4945.59 (S) FG=4957.99 SSMH A2-1.4 INV. IN=4944.49 (E) INV. OUT=4944.29 (W) FG=4957.27 SSMH A2-2.1 INV. OUT=4943.98 (S) FG=4954.34 SSMH A2-4 INV. IN=4942.44 (N) INV. OUT=4942.24 (SW) FG=4953.86 SSMH A2-3 INV. IN=4942.03 (NE) INV. OUT=4941.83 (W) FG=4953.31 SSMH A2-1.3-1 INV. OUT=4943.27 (S) FG=4952.87 SSMH A2-1.3 INV. IN=4942.77 (N) INV. IN=4942.77 (E) INV. OUT=4942.57 (S) FG=4952.26 SSMH A2-2 INV. IN=4941.02 (E) INV. IN=4941.02 (N) INV. OUT=4940.82 (W) FG=4950.98 SSMH A2-1.2 INV. IN=4941.96 (N) INV. OUT=4941.76 (S) FG=4951.10 SSMH A2-1.1 INV. IN=4941.50 (N) INV. OUT=4941.30 (S) FG=4950.70 SSMH A2-1 INV. IN=4939.85 (E) INV. IN=4939.85 (N) INV. OUT=4939.65 (W) SSMH A1 FG=4948.05 INV. IN=4938.64 (N) INV. OUT=4938.44 (SE) FG=4947.60 SSMH A2 INV. IN=4939.10 (W) INV. IN=4939.10 (E) INV. OUT=4938.90 (S) FG=4946.91 EXMH A INV. IN=4938.04 (NW) INV. IN=4936.11 (E) INV. OUT=4935.77 (SW) FG=4948.18 160.18 LF 12" PVC @ 0.25% 105.69 LF 12" PVC @ 0.25% 109.85 LF 8" PVC @ 0.50% 192.90 LF 8" PVC @ 0.50% 162.00 LF 8" PVC @ 0.50% 42.01 LF 8" PVC @ 0.50% 286.26 LF 8" PVC @ 1.10% 295.75 LF 8" PVC @ 1.00% 289.15 LF 8" PVC @ 0.50% 52.52 LF 8" PVC @ 0.50% 121.43 LF 8" PVC @ 0.50% 49.08 LF 8" PVC @ 1.02% 304.84 LF 8" PVC @ 0.50% 152.17 LF 8" PVC @ 1.80% 161.16 LF 8" PVC @ 1.00% EXMH B INV. IN=4941.34 (N) INV. IN=4941.34 (E) INV. OUT=4941.34 (S) FG=4960.27 SSMH B1 INV. IN=4941.88 (N) INV. OUT=4941.68 (S) FG=4960.16 67.04 LF 8" PVC @ 0.50% 338.30 LF 8" PVC @ 0.50% 14" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER STREET G STREET G STREET H STREET H ALLEY 16 ALLEY 16 ALLEY 20 ALLEY 21 ALLEY 16 ALLEY 22 ALLEY 23 SUNIGA ROAD 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8''x6" SWIVEL TEE w/TB & 6" GV N:134671.78 E:206626.30 FIRE HYDRANT ASSEMBLY N:134679.78 E:206626.40 BULL RUN LTD PARTNERSHIP 5575 DTC PKWY STE 250 GREENWOOD VILLAGE, CO 80111 DIVISION SEVEN SYSTEMS 8 GIBBS RD LARAMIE, WY 80207 OPPIE VERA N PO BOX 302 LAPORTE, CO 80535 65'  -  115' ROW 65'  - 130' ROW 20' 8''x6" SWIVEL TEE w/TB & 6" GV N:135004.03 E:206388.04 20' FIRE HYDRANT ASSEMBLY N:135194.90 E:206745.81 8" to 6" REDUCER w/ 6" GV N:135193.32 E:206736.58 20' 16' 18'  -  E VINE DRIVE STREET E 20' 36' -  57' ROW FIRE HYDRANT ASSEMBLY N:135417.23 E:206816.81 8''x6" SWIVEL TEE w/TB & 6" GV N:135417.27 E:206805.28 FIRE HYDRANT ASSEMBLY N:134940.68 E:206206.41 8''x6" SWIVEL TEE w/TB & 6" GV N:134972.23 E:206201.05 FIRE HYDRANT ASSEMBLY N:134408.91 E:206186.36 STORM DRAIN INLET INLET 60" HDPE FES INLET INLET CONNECT TO EXISTING MANHOLE FES (2) WITH TRASH RACK KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C2.06 UTILITY PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 18 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C2.05 MATCHLINE-SEE SHEET C2.03 MATCHLINE-SEE SHEET C2.04 MATCHLINE-SEE SHEET C2.03 C2.01 C2.02 C2.03 C2.04 C2.05 C2.06 14" W LEGEND: UD 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT (ELCO) STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITARY SEWER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 5. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY EDGE OF GRAVEL EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER PROPOSED UNDERDRAIN PROPOSED RIGHT OF WAY NOTES: EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER EXISTING WATER LINE W PROPOSED 14" WATER LINE PROPOSED 12" WATER LINE 12" W PROPOSED 8" WATER LINE 8" W ELEC H Y F D E S PROPOSED FIRE HYDRANT EXISITNG ELECTRIC BOX EXISTING FIRE HYDRANT EXISTING FES EXISTING WATER VALVE WV PROPOSED BUTTERFLY VALVE PROPOSED WATER VALVE EXISTING STORM SEWER ST X X X X X G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W 8" PVC WATER 8" PVC WATER 8" PVC WATER 24.45 LF 8" PVC R=300.00' 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER FIRE HYDRANT ASSEMBLY N:135146.01 E:205977.12 8'' TO 6'' REDUCER w/ 6" GV N:135138.39 E:205978.42 90° BEND w/TB N:135053.44 E:205563.62 8''x8'' TEE w/TB & 2 - 8" GV (N,E) N:134915.95 E:205562.08 CONNECT TO EXISTING 14" AC ELCO WATER MAIN N:134959.73 E:205396.43 14''x14'' TEE w/TB 1 - 14" BFV (S), 14" TO 8" REDUCER, & GV (E) N:134917.24 E:205471.01 14''x8'' TEE w/TB & 1-8" GV (N), 1-BFV (E) N:134684.33 E:205651.70 8''x8'' TEE w/TB & 2-8" GV (S,E) N:134914.92 E:205654.67 8''x8'' TEE w/TB & 2-8" GV (E, S) N:134917.63 E:205835.16 14''x8'' TEE w/TB & 1-8" GV (N), 1-BFV (E) N:134681.98 E:205833.57 14''x8'' TEE w/TB & 1-8" GV (N), 1-BFV (E) N:134679.45 E:206030.80 8''x8'' TEE w/TB & 3-8" GV (E,W,S) N:134942.79 E:206027.95 8''x8'' TEE w/TB & 1-8" GV (N) N:134945.89 E:206016.36 8''x8'' TEE w/TB & 2-8" GV (S,W) N:135075.66 E:205989.09 8''x8'' TEE w/TB & 3-8" GV (N,E,W) N:134991.74 E:206315.78 8''x8'' TEE w/TB N:134990.68 E:206309.57 8''x8'' TEE w/TB & 1-8" GV (N,E) N:135117.72 E:206294.36 CAP w/TB N:135189.83 E:206282.09 8''x8'' TEE w/TB & 2-8" GV (N,E) N:134676.02 E:206296.69 14''x14'' TEE w/TB 1 - 14" BFV (S), 14" TO 8" REDUCER, & GV (E) N:134677.99 E:206143.87 CONNECT TO EXISTING 14" AC ELCO WATER MAIN 14''x14'' TEE w/TB & 2-8" BFV (N,W) N:134344.62 E:206139.52 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT SSMH A2-1.3-1 INV. OUT=4943.27 (S) FG=4952.87 SSMH A3-5 INV. OUT=4943.82 (E) FG=4952.99 SSMH A8-3 INV. OUT=4944.60 (W) FG=4952.97 SSMH A8-2.1 INV. OUT=4944.26 (S) FG=4952.86 SSMH A8-2 INV. IN=4943.97 (E) INV. IN=4943.97 (N) INV. OUT=4943.77 (S) FG=4952.57 SSMH A2-1.3 INV. IN=4942.77 (N) INV. IN=4942.77 (E) INV. OUT=4942.57 (S) FG=4952.26 SSMH A3-4 INV. IN=4943.05 (W) INV. OUT=4942.85 (E) FG=4951.65 SSMH A8 INV. IN=4942.43 (W) INV. IN=4942.43 (E) INV. OUT=4942.23 (S) FG=4951.64 SSMH A8-1 INV. IN=4943.08 (N) INV. OUT=4942.88 (W) FG=4951.69 SSMH A9 INV. OUT=4942.58 (E) FG=4950.84 SSMH A5-1 INV. OUT=4941.67 (S) FG=4951.18 SSMH A3-3.1 INV. OUT=4942.61 (S) FG=4951.10 SSMH A2-1.2 INV. IN=4941.96 (N) INV. OUT=4941.76 (S) FG=4951.10 SSMH A2-1.1 INV. IN=4941.50 (N) INV. OUT=4941.30 (S) FG=4950.70 SSMH A7 INV. IN=4941.73 (N) INV. OUT=4941.53 (SE) FG=4950.54 SSMH A6 INV. IN=4941.42 (NW) INV. OUT=4941.22 (E) FG=4950.33 SSMH A3-3 INV. IN=4942.31 (W) INV. IN=4942.31 (N) INV. OUT=4942.11 (S) FG=4950.39 SSMH A4-1 INV. OUT=4941.09 (S) FG=4950.22 SSMH A5 INV. IN=4940.84 (N) INV. IN=4940.84 (W) INV. OUT=4940.64 (E) FG=4949.44 SSMH A3-2 INV. IN=4941.55 (N) INV. OUT=4941.35 (SE) FG=4949.34 SSMH A3-1 INV. IN=4941.08 (NW) INV. OUT=4940.88 (S) FG=4949.25 SSMH A4 INV. IN=4940.19 (N) INV. IN=4940.19 (W) INV. OUT=4939.99 (E) FG=4948.44 SSMH A2-1 INV. IN=4939.85 (E) INV. IN=4939.85 (N) INV. OUT=4939.65 (W) FG=4948.05 SSMH A3 INV. IN=4939.69 (N) INV. IN=4939.49 (W) INV. OUT=4939.49 (E) FG=4947.35 SSMH A1 INV. IN=4938.64 (N) INV. OUT=4938.44 (SE) FG=4947.60 SSMH A2 INV. IN=4939.10 (W) INV. IN=4939.10 (E) INV. OUT=4938.90 (S) FG=4946.91 EXMH A INV. IN=4938.04 (NW) INV. IN=4936.11 (E) INV. OUT=4935.77 (SW) FG=4948.18 160.18 LF 12" PVC @ 0.25% 105.69 LF 12" PVC @ 0.25% 156.05 LF 12" PVC @ 0.25% 236.77 LF 8" PVC @ 0.50% 52.42 LF 8" PVC @ 0.50% 112.75 LF 8" PVC @ 0.50% 107.75 LF 8" PVC @ 0.50% 153.70 LF 8" PVC @ 0.50% 59.12 LF 8" PVC @ 0.50% 197.25 LF 12" PVC @ 0.25% 181.84 LF 8" PVC @ 0.50% 181.89 LF 12" PVC @ 0.25% 166.30 LF 8" PVC @ 0.50% 152.90 LF 12" PVC @ 0.25% 43.39 LF 12" PVC @ 0.25% 199.60 LF 12" PVC @ 0.25% 109.85 LF 8" PVC @ 0.50% 192.90 LF 8" PVC @ 0.50% 289.15 LF 8" PVC @ 0.50% 52.52 LF 8" PVC @ 0.50% 121.43 LF 8" PVC @ 0.50% 49.08 LF 8" PVC @ 1.02% 61.15 LF 12" PVC @ 0.25% 91.09 LF 8" PVC @ 0.50% 137.50 LF 8" PVC @ 0.50% 125.82 LF 8" PVC @ 0.50% 58.19 LF 8" PVC @ 0.50% 14" PVC WATER 14" PVC WATER 14" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER STREET G STREET G STREET H STREET H ALLEY 15 ALLEY 15 ALLEY 16 ALLEY 16 ALLEY 17 ALLEY 18 ALLEY 19 ALLEY 20 ALLEY 22 ALLEY 23 ALLEY 24 ALLEY 25 SUNIGA ROAD 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT FIRE HYDRANT ASSEMBLY N:134690.75 E:205812.68 14''x6" SWIVEL TEE w/TB & 6" GV N:134682.26 E:205812.57 WEISS DONALD D/ BEVERLY A 1924 E. VINE DR. FORT COLLINS, CO 80524 CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 14''x6" SWIVEL TEE w/TB & 6" GV N:134685.60 E:205552.61 FIRE HYDRANT ASSEMBLY N:134693.60 E:205552.72 20' 16' 16' 16' 16' 20' 9' UTILITY EASEMENT 65' -  115' ROW 36' -  57' ROW 18'  -  80' ROW 18'  -  FIRE HYDRANT ASSEMBLY w/6" GV N:135139.50 E:205583.71 E VINE DRIVE FIRE HYDRANT ASSEMBLY N:134940.68 E:206206.41 8''x6" SWIVEL TEE w/TB & 6" GV N:134972.23 E:206201.05 FIRE HYDRANT ASSEMBLY N:134408.91 E:206186.36 14''x6" SWIVEL TEE w/TB & 6" GV N:134409.51 E:206140.37 EXISTING STORM DRAIN (TO BE CONSTRUCTED PER WATERFIELD 1ST FILING) OVERFLOW OUTFALL STORM DRAIN STORM DRAIN BIO-SWALE W/ UNDERDAIN INLET SIDEWALK CHASE STORM DRAIN STORM MH (TYP.) INLET INLET INLET INLET (2) FES FES INLET INLET ULTIMATE OUTFALL LOCATION FES (2) FES (2) KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C2.05 UTILITY PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 17 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C2.02 MATCHLINE-SEE SHEET C2.06 C2.01 C2.02 C2.03 C2.04 C2.05 C2.06 14" W LEGEND: UD 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT (ELCO) STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITARY SEWER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 5. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY EDGE OF GRAVEL EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER PROPOSED UNDERDRAIN PROPOSED RIGHT OF WAY NOTES: EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER EXISTING WATER LINE W PROPOSED 14" WATER LINE PROPOSED 12" WATER LINE 12" W PROPOSED 8" WATER LINE 8" W ELEC H Y F D E S PROPOSED FIRE HYDRANT EXISITNG ELECTRIC BOX EXISTING FIRE HYDRANT EXISTING FES EXISTING WATER VALVE WV PROPOSED BUTTERFLY VALVE PROPOSED WATER VALVE EXISTING STORM SEWER ST IRR IRR WV VAULT ELEC ELEC ELEC ELEC BRKR ELEC ELEC S S VAULT ELEC WV WV WV ELEC ELEC E GAS T VAULT ELEC VAULT C ELEC SS SS SS E E E E E H Y D W W W W W TELE WV WV WV S W SS SS SS IRR IRR IRR IRR W W W W W W W W W W W W W W W W W W W W W W H 2O GAS GAS IRR IRR IRR IRR D CONNECT TO EXISTING 12" ELCO WATER MAIN N:135016.66 E:206803.03 CONNNECT TO EXISTING 12" ELCO WATER MAIN N:135017.49 E:206803.71 8''x8'' TEE w/TB & 2-8" GV (N,W) N:135490.84 E:207189.73 8''x8'' TEE w/TB & 2-8" GV (N,E) N:135573.42 E:207233.94 8''x8'' TEE w/TB & 1-8" GV (N) N:135569.96 E:207426.91 8''x8'' TEE w/TB & 1-8" GV (E) N:135569.20 E:207469.54 8''x8'' TEE w/TB & 1-8" GV (S,E) N:135744.34 E:207602.40 8''x8'' TEE w/TB & 2-8" GV (N,E) N:135742.46 E:207707.05 8''x8'' TEE w/TB & 2-8" GV (S,E) N:135740.75 E:207802.37 8''x8'' TEE w/TB & 2-8' GV (E,S) N:135473.54 E:207467.93 8''x8'' TEE w/TB & 2-8" GV (E.S) N:135747.43 E:207430.09 8''x8'' TEE w/TB & 2-8" GV (E,S) N:135750.90 E:207237.13 8''x8'' TEE w/TB & 2-8" GV (N,E) N:135721.54 E:207013.82 8''X12" CROSS w/TB & 2-12" BFV (E,W) 2-8" GV (N, N:135879.34 E:206932.19 N:135908.11 E:207710.02 CAP w/TB N:135447.28 E:207188.90 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER CAP w/TB N:135441.24 E:207467.38 8''x6" SWIVEL TEE w/TB & 6" GV N:135571.15 E:207360.42 FIRE HYDRANT ASSEMBLY N:135559.91 E:207360.22 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT SSMH B4-17 INV. OUT=4956.14 (S) FG=4964.53 SSMH B10-2 INV. OUT=4953.27 (S) FG=4964.49 SSMH B14-1 INV. OUT=4955.21 (W) SSMH B4-1.1 FG=4963.69 INV. IN=4949.66 (NW) INV. OUT=4949.46 (SW) FG=4963.68 SSMH B4-16 INV. IN=4955.46 (N) INV. OUT=4955.26 (S) FG=4963.19 SSMH B4-15 INV. IN=4955.09 (N) INV. OUT=4954.89 (SW) FG=4962.85 SSMH B4-8.1 INV. OUT=4950.84 (S) FG=4962.18 SSMH B4-14 INV. IN=4954.58 (NE) INV. OUT=4954.38 (SW) FG=4962.27 SSMH B4-7 INV. IN=4949.64 (E) INV. OUT=4949.44 (S) FG=4961.86 SSMH B4-13 INV. IN=4954.08 (NE) INV. OUT=4953.88 (W) FG=4961.68 SSMH B4-2 INV. IN=4946.63 (SE) INV. OUT=4946.43 (NW) FG=4961.61 SSMH B4-8 INV. IN=4950.06 (E) INV. IN=4950.06 (N) INV. OUT=4949.86 (W) FG=4961.54 SSMH B4-1 INV. IN=4946.10 (NE) INV. IN=4946.10 (SE) INV. OUT=4945.90 (SW) FG=4961.37 SSMH B4-3 INV. IN=4947.24 (SE) INV. OUT=4947.04 (NW) FG=4961.18 SSMH B4-12 INV. IN=4953.64 (E) INV. OUT=4953.44 (W) FG=4961.17 SSMH B4-9.1 INV. OUT=4952.00 (S) FG=4960.85 SSMH B4-4 INV. IN=4947.85 (E) INV. OUT=4947.65 (NW) FG=4960.74 EXMH B INV. IN=4941.34 (N) INV. IN=4941.34 (E) INV. OUT=4941.34 (S) FG=4960.27 SSMH B10-1 INV. IN=4952.48 (N) INV. IN=4952.48 (E) INV. OUT=4952.28 (W) FG=4960.40 SSMH B4-5 INV. IN=4948.46 (E) INV. OUT=4948.26 (W) FG=4960.31 SSMH B1 INV. IN=4941.88 (N) INV. OUT=4941.68 (S) FG=4960.16 SSMH B4-6 INV. IN=4948.91 (N) INV. OUT=4948.71 (W) FG=4959.61 SSMH B4-9 INV. IN=4951.22 (E) INV. IN=4951.22 (N) INV. OUT=4951.02 (W) FG=4959.38 SSMH B4-10 INV. IN=4951.63 (S) INV. IN=4951.63 (E) INV. OUT=4951.43 (W) FG=4959.37 SSMH B4-11 INV. IN=4952.41 (E) INV. OUT=4952.21 (N) FG=4959.01 SSMH B3 INV. IN=4944.37 (N) INV. OUT=4944.17 (S) FG=4956.14 SSMH B2 INV. IN=4943.77 (N) INV. OUT=4943.57 (S) FG=4955.45 67.04 LF 8" PVC @ 0.50% 338.30 LF 8" PVC @ 0.50% 80.71 LF 8" PVC @ 0.50% 168.18 LF 8" PVC @ 0.50% 112.16 LF 8" PVC @ 3.00% 67.56 LF 8" PVC @ 0.50% 81.93 LF 8" PVC @ 0.50% 81.93 LF 8" PVC @ 0.50% 81.93 LF 8" PVC @ 0.50% 51.12 LF 8" PVC @ 0.50% 42.63 LF 8" PVC @ 0.50% 115.64 LF 8" PVC @ 0.50% 206.10 LF 8" PVC @ 0.50% 46.74 LF 8" PVC @ 0.50% 60.89 LF 8" PVC @ 0.50% 60.89 LF 8" PVC @ 0.50% 135.75 LF 8" PVC @ 0.50% 35.81 LF 8" PVC @ 0.50% 193.00 LF 8" PVC @ 0.50% 42.63 LF 8" PVC @ 0.50% 129.71 LF 8" PVC @ 0.50% 156.50 LF 8" PVC @ 0.50% 163.50 LF 8" PVC @ 0.50% 156.50 LF 8" PVC @ 0.50% 156.50 LF 8" PVC @ 0.50% 8" PVC WATER 8" PVC WATER 12" PVC WATER 12" PVC WATER 12" PVC WATER 8''x6" SWIVEL TEE w/TB & 6" GV N:135740.38 E:207004.08 FIRE HYDRANT ASSEMBLY N:135745.50 E:207014.09 STREET A STREET C STREET C STREET D STREET D ALLEY 2 ALLEY 1 ALLEY 3 ALLEY 4 ALLEY 4 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 5 ALLEY 6 ALLEY 7 FIRE HYDRANT ASSEMBLY N:135739.39 E:207878.49 8" GV w/8" TO 6" REDUCER N:135739.55 E:207869.23 36.5'  - 57' ROW 36' -  60' ROW 20' 16' 16' 18' -  9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT FIRE HYDRANT ASSEMBLY N:135907.76 E:207228.24 9' UTILITY EASEMENT SUNIGA ROAD BULL RUN LTD PARTNERSHIP 5575 DTC PKWY STE 250 GREENWOOD VILLAGE, CO 80111 OPPIE VERA N PO BOX 302 LAPORTE, CO 80535 30'  -  51' ROW 65' - 130' ROW 20' INLET (2) FES 20' STREET E SSMH B15 INV. IN=4961.44 (N) INV. IN=4961.44 (W) INV. OUT=4961.24 (S) FG=4973.26 60.53 LF 8" PVC @ 0.50% SSMH B15-1 INV. IN=4961.94 (W) INV. OUT=4961.74 (E) FG=4972.89 SSMH B15-2 INV. IN=4962.41 (W) INV. OUT=4962.21 (E) FG=4972.32 224.71 LF 8" PVC @ 0.50% 264.47 LF 8" PVC @ 0.50% SSMH B4-1.4 INV. IN=4956.45 (E) INV. OUT=4956.25 (W) FG=4970.10 SSMH B4-1.3 INV. IN=4954.93 (E) INV. OUT=4954.73 (SW) FG=4966.49 116.83 LF 8" PVC @ 2.00% 126.35 LF 8" PVC @ 2.00% SSMH B4-1.2 INV. IN=4952.39 (NE) INV. OUT=4952.19 (SE) FG=4964.51 136.96 LF 8" PVC @ 5.00% SSMH B14 INV. IN=4954.39 (N) INV. IN=4954.39 (E) INV. OUT=4954.19 (S) FG=4966.59 142.00 LF 8" PVC @ 0.50% SSMH B13 INV. IN=4953.48 (N) INV. OUT=4953.28 (SW) FG=4961.82 50.20 LF 8" PVC @ 0.50% SSMH B12 INV. IN=4953.03 (NE) INV. OUT=4952.83 (W) FG=4961.09 69.17 LF 8" PVC @ 0.50% FIRE HYDRANT ASSEMBLY N:135917.25 E:207925.37 12''x6" SWIVEL TEE w/TB & 6" GV 1-8" GV (W) N:135904.26 E:207925.13 FIRE HYDRANT ASSEMBLY N:135417.23 E:206816.81 PROPOSED STORM DRAIN INLET FES FES FES STORM DRAIN INLET INLET INLET IRRIGATION MANHOLE (TIE TO EXISTING) IRRIGATION LINE KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C2.04 UTILITY PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 16 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C2.06 MATCHLINE-SEE SHEET C2.02 MATCHLINE-SEE SHEET C2.03 C2.01 C2.02 C2.03 C2.04 C2.05 C2.06 14" W LEGEND: UD 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT (ELCO) STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITARY SEWER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 5. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY EDGE OF GRAVEL EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER PROPOSED UNDERDRAIN PROPOSED RIGHT OF WAY NOTES: EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER EXISTING WATER LINE W PROPOSED 14" WATER LINE PROPOSED 12" WATER LINE 12" W PROPOSED 8" WATER LINE 8" W ELEC H Y F D E S PROPOSED FIRE HYDRANT EXISITNG ELECTRIC BOX EXISTING FIRE HYDRANT EXISTING FES EXISTING WATER VALVE WV PROPOSED BUTTERFLY VALVE PROPOSED WATER VALVE EXISTING STORM SEWER ST N:135146.01 E:205977.12 8'' TO 6'' REDUCER w/ 6" GV N:135138.39 E:205978.42 8''x8'' TEE w/TB & 1-8" GV (N,E) N:135117.72 E:206294.36 CAP w/TB N:135189.83 E:206282.09 90° BEND w/TB N:135180.65 E:206662.45 8''x8'' TEE w/TB & 2-8" GV (N,E) N:135515.34 E:206615.23 12''x12'' TEE w/TB & 2-12" BFV (N,E) N:135750.53 E:206683.20 8''x8'' TEE w/TB & 2-8" GV (E,S) N:135804.58 E:206488.05 8''x8'' TEE w/TB & 2-8" GV (E,S) N:135974.49 E:206403.33 8''x8'' TEE w/TB & 2-12" GV (N,W) N:136178.78 E:206777.57 8''x8'' TEE w/TB & 2-8" GV (N,E) N:136094.58 E:206820.84 8''X12" CROSS w/TB & 2-12" BFV (E,W) 2-8" GV (N, N:135879.34 E:206932.19 8''X8" TEE w/TB & 2-8" GV (N,W) N:136001.62 E:206868.93 8''X12" CROSS w/TB & 1-12" GV (N) 2-8" GV (E,W) N:136049.85 E:206528.35 8''X12" CROSS w/TB & 1-12" BFV (N) 2-8" GV (E,W) N:135872.81 E:206619.94 8''X12" CROSS w/TB & 2-12" GV (N,S) 2-8" GV (E,W) N:135592.73 E:206764.83 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER FIRE HYDRANT ASSEMBLY N:136006.31 E:206386.87 CAP w/TB N:135922.30 E:206430.33 8" PVC WATER 8" PVC WATER 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT SSMH A2-6 INV. OUT=4947.40 (S) FG=4958.50 SSMH A2-1.5 INV. OUT=4947.23 (W) FG=4959.10 SSMH A2-1.4 INV. IN=4944.49 (E) INV. OUT=4944.29 (W) FG=4957.27 SSMH A2-1.3-1 INV. OUT=4943.27 (S) FG=4952.87 SSMH A2-1.3 INV. IN=4942.77 (N) INV. IN=4942.77 (E) INV. OUT=4942.57 (S) FG=4952.26 SSMH A3-3.1 INV. OUT=4942.61 (S) FG=4951.10 49.08 LF 8" PVC @ 1.02% 304.84 LF 8" PVC @ 0.50% 152.17 LF 8" PVC @ 1.80% SSMH B5-1.1 INV. IN=4955.74 (NE) INV. OUT=4955.54 (SE) FG=4968.41 SSMH B5-1.2 INV. IN=4956.91 (NW) INV. IN=4956.91 (NE) INV. OUT=4956.71 (SW) FG=4969.50 SSMH B4-1.1 INV. IN=4949.66 (NW) INV. OUT=4949.46 (SW) FG=4963.68 SSMH B4-2 INV. IN=4946.63 (SE) INV. OUT=4946.43 (NW) FG=4961.61 SSMH B4-1 INV. IN=4946.10 (NE) INV. IN=4946.10 (SE) INV. OUT=4945.90 (SW) FG=4961.37 SSMH B7 INV. IN=4949.77 (N) INV. OUT=4949.57 (SE) FG=4960.66 SSMH B6 INV. IN=4947.92 (NW) INV. IN=4947.92 (NE) INV. IN=4947.92 (SW) INV. OUT=4947.72 (SE) FG=4958.90 SSMH B6W-1 INV. IN=4948.31 (SW) INV. OUT=4948.11 (NE) FG=4958.82 SSMH B5 INV. IN=4946.73 (NE) INV. IN=4946.73 (NW) INV. IN=4946.73 (SW) INV. OUT=4946.53 (SE) FG=4958.40 SSMH B4 INV. IN=4945.06 (SW) INV. IN=4945.06 (NW) INV. IN=4945.06 (NE) INV. OUT=4944.86 (S) FG=4957.64 SSMH B6W-2 INV. IN=4948.93 (NW) INV. IN=4948.93 (S) INV. OUT=4948.73 (NE) FG=4957.50 SSMH B6W-3 INV. OUT=4949.09 (SE) FG=4957.71 SSMH B3 INV. IN=4944.37 (N) INV. OUT=4944.17 (S) FG=4956.14 SSMH B6W-2.1 INV. OUT=4949.12 (N) FG=4957.02 SSMH B5W-1.1 INV. OUT=4947.82 (NW) FG=4956.32 SSMH B5W-1 INV. IN=4947.67 (NW) INV. IN=4947.67 (SE) INV. OUT=4947.47 (NE) FG=4956.04 SSMH B2 INV. IN=4943.77 (N) INV. OUT=4943.57 (S) FG=4955.45 SSMH B5W-2 INV. OUT=4947.87 (SE) FG=4955.67 SSMH B4W-1 INV. IN=4946.10 (NW) INV. IN=4946.10 (SE) INV. OUT=4945.90 (NE) FG=4955.48 SSMH B4W-2 INV. OUT=4946.25 (SE) FG=4955.76 SSMH B4W-1.1 INV. OUT=4946.30 (NW) FG=4955.11 338.30 LF 8" PVC @ 0.50% 80.71 LF 8" PVC @ 0.50% 97.78 LF 8" PVC @ 0.50% 295.33 LF 8" PVC @ 0.50% 280.33 LF 8" PVC @ 2.70% 104.67 LF 8" PVC @ 1.00% 96.67 LF 8" PVC @ 1.00% 88.34 LF 8" PVC @ 0.50% 127.07 LF 8" PVC @ 1.30% 199.33 LF 8" PVC @ 0.50% 236.93 LF 8" PVC @ 2.80% 38.86 LF 8" PVC @ 0.50% 82.79 LF 8" PVC @ 0.50% 31.89 LF 8" PVC @ 0.50% 37.97 LF 8" PVC @ 0.50% 39.58 LF 8" PVC @ 0.50% 168.44 LF 8" PVC @ 0.50% 29.53 LF 8" PVC @ 0.50% 39.63 LF 8" PVC @ 0.50% 148.50 LF 8" PVC @ 0.50% 29.58 LF 8" PVC @ 0.50% 168.18 LF 8" PVC @ 0.50% 112.16 LF 8" PVC @ 3.00% 67.56 LF 8" PVC @ 0.50% 81.93 LF 8" PVC @ 0.50% 8" PVC WATER 8" PVC WATER 8" PVC WATER 12" PVC WATER 12" PVC WATER 16' ROW STREET B STREET D STREET E ALLEY 8 ALLEY 8 ALLEY 9 ALLEY 12 STREET G ALLEY 23 12" PVC WATER 8' UTILITY EASEMENT 8' UTILITY EASEMENT FIRE HYDRANT ASSEMBLY N:135847.65 E:206465.76 8" TO 6" REDUCER w/ 6" GV N:135842.10 E:206468.64 CAP w/TB N:135762.09 E:206510.03 8''x6" SWIVEL TEE w/TB & 6" GV N:136119.45 E:206807.97 FIRE HYDRANT ASSEMBLY N:136124.62 E:206817.97 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT FIRE HYDRANT ASSEMBLY N:135472.26 E:206637.52 8" TO 6" REDUCER w/ 6" GV N:135477.74 E:206634.68 SUNIGA ROAD CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 20' 20' 20' FIRE HYDRANT ASSEMBLY N:135718.50 E:206664.30 12''x6" SWIVEL TEE w/TB & 6" GV N:135732.98 E:206692.28 65'  -  115' ROW 36.5'  -  57' ROW 20' FIRE HYDRANT ASSEMBLY N:135194.90 E:206745.81 8" to 6" REDUCER w/ 6" GV N:135193.32 E:206736.58 36'  -  57' ROW 8''x8'' TEE w/TB & 3-8" GV (N,E,W) N:136138.99 E:206906.68 116.83 LF 8" PVC @ 2.00% 126.35 LF 8" PVC @ 2.00% SSMH B4-1.2 INV. IN=4952.39 (NE) INV. OUT=4952.19 (SE) FG=4964.51 FIRE HYDRANT ASSEMBLY N:136068.04 E:206531.61 8''x6" SWIVEL TEE w/TB & 6" GV N:136062.87 E:206521.62 FIRE HYDRANT ASSEMBLY N:135417.23 E:206816.81 8''x6" SWIVEL TEE w/TB & 6" GV N:135417.27 E:206805.28 FES STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN STORM DRAIN INLET (2) HEADWALL WITH TRASH RACK FES INLET INLET FES INLET INLET FES POND OUTFALL FES OVERFLOW OUTFALL STORM DRAIN STORM DRAIN BIO-SWALE W/ UNDERDAIN INLET SIDEWALK CHASE STORM DRAIN STORM MH (TYP.) FES FES HEADWALL WITH TRASH RACK HEADWALL WITH TRASH RACK KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C2.03 UTILITY PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 15 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C2.05 MATCHLINE-SEE SHEET C2.02 MATCHLINE-SEE SHEET C2.01 MATCHLINE-SEE SHEET C2.06 MATCHLINE-SEE SHEET C2.04 C2.01 C2.02 C2.03 C2.04 C2.05 C2.06 14" W LEGEND: UD 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT (ELCO) STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITARY SEWER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 5. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY EDGE OF GRAVEL EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER PROPOSED UNDERDRAIN PROPOSED RIGHT OF WAY NOTES: EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER EXISTING WATER LINE W PROPOSED 14" WATER LINE PROPOSED 12" WATER LINE 12" W PROPOSED 8" WATER LINE 8" W ELEC H Y F D E S PROPOSED FIRE HYDRANT EXISITNG ELECTRIC BOX EXISTING FIRE HYDRANT EXISTING FES EXISTING WATER VALVE WV PROPOSED BUTTERFLY VALVE PROPOSED WATER VALVE EXISTING STORM SEWER ST IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR N YLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W H2O WV WV WV TEST STA ELEC ELEC E E E E X X X X X X X X X W W W W W W W W W W W W W W W H2O 8''x8'' TEE w/TB & 2-8" GV (S,E) N:135671.22 E:206916.55 8''x8'' TEE w/TB & 1-8" GV (S,E) N:135744.34 E:207602.40 8''x8'' TEE w/TB & 2-8" GV (N,E) N:135742.46 E:207707.05 8''x8'' TEE w/TB & 2-8" GV (S,E) N:135740.75 E:207802.37 8''x8'' TEE w/TB & 2-8" GV (E.S) N:135747.43 E:207430.09 8''x8'' TEE w/TB & 2-8" GV (E,S) N:135750.90 E:207237.13 8''x8'' TEE w/TB & 2-8" GV (N,E) N:135721.54 E:207013.82 8''x12'' TEE w/TB & 1-12" GV (N) 1-8" GV (E) N:136310.11 E:206753.34 8''x8'' TEE w/TB & 2-12" GV (N,W) N:136178.78 E:206777.57 8''x8'' TEE w/TB & 2-8" GV (N,E) N:136094.58 E:206820.84 8''x8'' TEE w/TB & 3-8" GV (N,E,W) N:136055.76 E:207712.67 8''X12" CROSS w/TB & 2-12" BFV (E,W) 2-8" GV (N, N:135879.34 E:206932.19 8''X8" TEE w/TB & 2-8" GV (N,W) N:136001.62 E:206868.93 8''X12" CROSS w/TB & 1-12" BFV (E) 2-8" GV (N,S) N:135908.11 E:207710.02 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER 8" PVC WATER CAP w/TB N:135903.92 E:207943.81 8''x6" SWIVEL TEE w/TB & 6" GV N:135571.15 E:207360.42 8" PVC WATER 8''x6" SWIVEL TEE w/TB & 6" GV N:136161.08 E:207677.08 FIRE HYDRANT ASSEMBLY N:136125.09 E:207677.08 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT SSMH B16-6 INV. OUT=4970.28 (E) FG=4981.03 SSMH B5-1.8 INV. OUT=4969.37 (W) FG=4980.51 SSMH B16-5 INV. IN=4968.32 (W) INV. OUT=4968.12 (SE) FG=4979.10 SSMH B16-4 INV. IN=4967.82 (NW) INV. OUT=4967.62 (SE) FG=4978.52 SSMH B16-3 INV. IN=4967.35 (NW) INV. OUT=4967.15 (S) FG=4977.97 SSMH B16-2 INV. IN=4966.86 (N) INV. OUT=4966.66 (S) FG=4977.43 SSMH B5-1.7 INV. IN=4965.70 (E) INV. OUT=4965.51 (W) FG=4976.67 SSMH B16-1 INV. IN=4966.13 (E) INV. IN=4966.13 (N) INV. OUT=4965.93 (W) FG=4976.20 SSMH B16-1.1 INV. OUT=4966.60 (W) FG=4975.96 SSMH B16 INV. IN=4964.77 (E) INV. IN=4964.77 (N) INV. OUT=4964.57 (S) FG=4976.80 SSMH B5-1.6 INV. IN=4959.81 (E) INV. OUT=4959.61 (W) FG=4970.78 SSMH B5-1.5 INV. IN=4958.29 (E) INV. OUT=4958.09 (SW) FG=4969.18 SSMH B5-1.4 INV. IN=4957.91 (NE) INV. OUT=4957.71 (S) FG=4969.11 SSMH B5-1.3 INV. IN=4957.55 (N) INV. OUT=4957.35 (SE) FG=4969.31 SSMH B5-1.1 INV. IN=4955.74 (NE) INV. OUT=4955.54 (SE) FG=4968.41 SSMH B5-1.2 INV. IN=4956.91 (NW) INV. IN=4956.91 (NE) INV. OUT=4956.71 (SW) FG=4969.50 SSMH B5-1 INV. IN=4954.50 (NW) INV. OUT=4954.30 (SW) FG=4966.78 SSMH B4-17 INV. OUT=4956.14 (S) FG=4964.53 SSMH B10-2 INV. OUT=4953.27 (S) FG=4964.49 SSMH B14-1 INV. OUT=4955.21 (W) SSMH B4-1.1 FG=4963.69 INV. IN=4949.66 (NW) INV. OUT=4949.46 (SW) FG=4963.68 SSMH B4-8.1 INV. OUT=4950.84 (S) FG=4962.18 SSMH B4-1 INV. IN=4946.10 (NE) INV. IN=4946.10 (SE) INV. OUT=4945.90 (SW) FG=4961.37 SSMH B4-9.1 INV. OUT=4952.00 (S) FG=4960.85 SSMH B4-9 INV. IN=4951.22 (E) INV. IN=4951.22 (N) INV. OUT=4951.02 (W) FG=4959.38 104.67 LF 8" PVC @ 1.00% 96.67 LF 8" PVC @ 1.00% 88.34 LF 8" PVC @ 0.50% 33.41 LF 8" PVC @ 0.50% 36.38 LF 8" PVC @ 0.50% 82.36 LF 8" PVC @ 1.60% 300.00 LF 8" PVC @ 1.90% 192.93 LF 8" PVC @ 1.90% 137.71 LF 8" PVC @ 3.80% 140.36 LF 8" PVC @ 3.00% 168.18 LF 8" PVC @ 0.50% 112.16 LF 8" PVC @ 3.00% 67.56 LF 8" PVC @ 0.50% 135.75 LF 8" PVC @ 0.50% 116.66 LF 8" PVC @ 1.00% 46.83 LF 8" PVC @ 1.00% 105.97 LF 8" PVC @ 0.50% 56.92 LF 8" PVC @ 0.50% 55.17 LF 8" PVC @ 0.50% 59.30 LF 8" PVC @ 0.50% 196.30 LF 8" PVC @ 1.00% 156.50 LF 8" PVC @ 0.50% 163.50 LF 8" PVC @ 0.50% 156.50 LF 8" PVC @ 0.50% 156.50 LF 8" PVC @ 0.50% 8" PVC WATER 8" PVC WATER 8" PVC WATER 12" PVC WATER 12" PVC WATER 12" PVC WATER 16' FIRE HYDRANT ASSEMBLY N:136280.09 E:207491.16 8''x6" SWIVEL TEE w/TB & 6" GV 1-8" GV (W) N:136261.09 E:207490.82 8''x6" SWIVEL TEE w/TB & 6" GV N:135740.38 E:207004.08 FIRE HYDRANT ASSEMBLY N:135745.50 E:207014.09 STREET B STREET C STREET C STREET C STREET D STREET D ALLEY 4 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 5 ALLEY 6 ALLEY 7 ALLEY 9 ALLEY 9 ALLEY 10 ALLEY 10 ALLEY 11 ALLEY 13 FIRE HYDRANT ASSEMBLY N:135739.39 E:207878.49 8" GV w/8" TO 6" REDUCER N:135739.55 E:207869.23 12" BFV N:135925.10 E:207323.32 8" GV N:136167.16 E:207338.06 36' -  57' ROW 36.5'  - 57' ROW 36'  - 57' ROW 20' 16' 36' -  60' ROW 20' 16' 16' 18' -  80' ROW 18'  -  8''x6" SWIVEL TEE w/TB & 6" GV N:136119.45 E:206807.97 FIRE HYDRANT ASSEMBLY N:136124.62 E:206817.97 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT FIRE HYDRANT ASSEMBLY N:135907.76 E:207228.24 9' UTILITY EASEMENT K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 36'  - 57' ROW 12''x6" SWIVEL TEE w/TB & 6" GV N:135926.75 E:207228.58 8" PVC WATER 8''x8'' TEE w/TB & 3-8" GV (N,E,W) N:136138.99 E:206906.68 41.27 LF 8" PVC @ 2.00% SSMH B5-1.2.1 INV. IN=4957.93 (E) INV. OUT=4957.73 (SW) FG=4970.25 80.90 LF 8" PVC @ 2.00% SSMH B5-1.2.2 INV. IN=4959.75 (E) INV. OUT=4959.55 (W) FG=4971.72 450.64 LF 8" PVC @ 2.00% SSMH B5-1.2.3 INV. OUT=4968.76 (W) FG=4979.83 SSMH B21 INV. OUT=4971.00 (E) FG=4980.52 156.50 LF 8" PVC @ 2.00% SSMH B20 INV. IN=4967.87 (W) INV. OUT=4967.67 (SE) FG=4980.21 29.47 LF 8" PVC @ 2.00% SSMH B17 INV. IN=4966.29 (N) INV. OUT=4966.09 (S) FG=4978.78 SSMH B18 INV. IN=4967.08 (NW) INV. OUT=4966.88 (S) FG=4979.59 29.47 LF 8" PVC @ 2.00% 66.17 LF 8" PVC @ 2.00% 156.38 LF 8" PVC @ 2.00% SSMH B15 INV. IN=4961.44 (N) INV. IN=4961.44 (W) INV. OUT=4961.24 (S) FG=4973.26 60.53 LF 8" PVC @ 0.50% SSMH B15-1 INV. IN=4961.94 (W) INV. OUT=4961.74 (E) FG=4972.89 SSMH B15-2 INV. IN=4962.41 (W) INV. OUT=4962.21 (E) FG=4972.32 224.71 LF 8" PVC @ 0.50% SSMH B15-3 INV. OUT=4963.54 (E) FG=4970.77 264.47 LF 8" PVC @ 0.50% SSMH B4-1.4 INV. IN=4956.45 (E) INV. OUT=4956.25 (W) FG=4970.10 SSMH B4-1.3 INV. IN=4954.93 (E) INV. OUT=4954.73 (SW) FG=4966.49 116.83 LF 8" PVC @ 2.00% 126.35 LF 8" PVC @ 2.00% SSMH B4-1.2 INV. IN=4952.39 (NE) INV. OUT=4952.19 (SE) FG=4964.51 136.96 LF 8" PVC @ 5.00% SSMH B14 INV. IN=4954.39 (N) INV. IN=4954.39 (E) INV. OUT=4954.19 (S) FG=4966.59 142.00 LF 8" PVC @ 0.50% SSMH B13 INV. IN=4953.48 (N) INV. OUT=4953.28 (SW) FG=4961.82 FIRE HYDRANT ASSEMBLY N:135917.25 E:207925.37 12''x6" SWIVEL TEE w/TB & 6" GV 1-8" GV (W) N:135904.26 E:207925.13 NATURAL HABITAT BUFFER ZONE INLET FES FES STORM DRAIN INLET INLET INLET HEADGATE CONNECTION FOR EXISTING IRRIGATION CANAL RE-ROUTE IRRIGATION MANHOLE IRRIGATION MANHOLE JUNCTION IRRIGATION LINE KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C2.02 UTILITY PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 14 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R MATCHLINE-SEE SHEET C2.04 MATCHLINE-SEE SHEET C2.03 MATCHLINE-SEE SHEET C2.01 C2.01 C2.02 C2.03 C2.04 C2.05 C2.06 14" W LEGEND: UD 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT (ELCO) STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITARY SEWER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 5. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY EDGE OF GRAVEL EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER PROPOSED UNDERDRAIN PROPOSED RIGHT OF WAY NOTES: EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER EXISTING WATER LINE W PROPOSED 14" WATER LINE PROPOSED 12" WATER LINE 12" W PROPOSED 8" WATER LINE 8" W ELEC H Y F D E S PROPOSED FIRE HYDRANT EXISITNG ELECTRIC BOX EXISTING FIRE HYDRANT EXISTING FES EXISTING WATER VALVE WV PROPOSED BUTTERFLY VALVE PROPOSED WATER VALVE EXISTING STORM SEWER ST W W W W W W W W W W W W W W W W W W W W W W W W W W W W W 12''x8'' TEE w/TB & 1-8" GV (W) 1-12" BFV (N) N:136239.51 E:206471.70 12''x8'' TEE w/TB & 1-12" BFV (N) 1-8" GV (E) N:136712.44 E:206509.61 12''x8'' TEE w/TB & 1-12" BV (N) 1-8" GFV (E) N:136315.13 E:206473.06 8''x12'' TEE w/TB & 1-12" GV (N) 1-8" GV (E) N:136310.11 E:206753.34 8''x8'' TEE w/TB & 2-12" GV (N,W) N:136178.78 E:206777.57 8''x8'' TEE w/TB & 2-8" GV (N,E) N:136094.58 E:206820.84 8''X8" TEE w/TB & 2-8" GV (N,W) N:136001.62 E:206868.93 8''X12" CROSS w/TB & 1-12" GV (N) 2-8" GV (E,W) N:136049.85 E:206528.35 8" PVC WATER 8" PVC WATER 8" PVC WATER FIRE HYDRANT ASSEMBLY N:136006.31 E:206386.87 8" PVC WATER CONNECT TO EXISTING 24" DUCTILE IRON PIPE ELCO WATER MAIN N:136764.06 E:206296.87 CONNECT TO EXISTING 24" DUCTILE IRON PIPE ELCO WATER MAIN N:136750.49 E:206526.69 22.50° BEND w/TB N:136742.37 E:206526.26 8" PVC WATER 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 8' UTILITY EASEMENT 8' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT SSMH B8-4 INV. OUT=4971.18 (S) FG=4981.53 SSMH B9-3 INV. OUT=4966.26 (S) FG=4977.35 SSMH B11 INV. OUT=4965.99 (S) FG=4977.13 SSMH B9-2 INV. IN=4962.05 (N) INV. OUT=4961.85 (S) FG=4973.06 SSMH B5-1.5 INV. IN=4958.29 (E) INV. OUT=4958.09 (SW) FG=4969.18 SSMH B5-1.4 INV. IN=4957.91 (NE) INV. OUT=4957.71 (S) FG=4969.11 SSMH B5-1.3 INV. IN=4957.55 (N) INV. OUT=4957.35 (SE) FG=4969.31 SSMH B9-1 INV. IN=4956.61 (N) INV. OUT=4956.41 (W) FG=4968.63 SSMH B5-1.1 INV. IN=4955.74 (NE) INV. OUT=4955.54 (SE) FG=4968.41 SSMH B5-1.2 INV. IN=4956.91 (NW) INV. IN=4956.91 (NE) INV. OUT=4956.71 (SW) FG=4969.50 SSMH B6-1 INV. OUT=4954.55 (SW) FG=4965.65 SSMH B8-2 INV. IN=4953.77 (N) INV. OUT=4953.57 (SE) FG=4964.78 SSMH B8-1 INV. IN=4953.06 (NW) INV. OUT=4952.86 (E) FG=4964.03 SSMH B10 INV. IN=4953.11 (N) INV. OUT=4952.91 (S) FG=4964.44 SSMH B9 INV. IN=4952.21 (N) INV. IN=4952.21 (E) INV. OUT=4952.01 (S) FG=4963.16 SSMH B8 INV. IN=4951.02 (W) INV. IN=4951.02 (N) INV. OUT=4950.82 (S) SSMH B7 FG=4961.99 INV. IN=4949.77 (N) INV. OUT=4949.57 (SE) FG=4960.66 SSMH B6 INV. IN=4947.92 (NW) INV. IN=4947.92 (NE) INV. IN=4947.92 (SW) INV. OUT=4947.72 (SE) FG=4958.90 SSMH B6W-1 INV. IN=4948.31 (SW) INV. OUT=4948.11 (NE) FG=4958.82 SSMH B6W-3 INV. OUT=4949.09 (SE) FG=4957.71 104.67 LF 8" PVC @ 1.00% 96.67 LF 8" PVC @ 1.00% 88.34 LF 8" PVC @ 0.50% 33.41 LF 8" PVC @ 0.50% 36.38 LF 8" PVC @ 0.50% 82.36 LF 8" PVC @ 1.60% 127.07 LF 8" PVC @ 1.30% 80.56 LF 8" PVC @ 1.30% 166.52 LF 8" PVC @ 1.10% 46.68 LF 8" PVC @ 1.10% 215.18 LF 8" PVC @ 4.00% 75.63 LF 8" PVC @ 1.30% 53.83 LF 8" PVC @ 1.30% 299.63 LF 8" PVC @ 4.30% 280.33 LF 8" PVC @ 1.50% 137.71 LF 8" PVC @ 3.80% 140.36 LF 8" PVC @ 3.00% 236.93 LF 8" PVC @ 2.80% 38.86 LF 8" PVC @ 0.50% 82.79 LF 8" PVC @ 0.50% 8" PVC WATER 8" PVC WATER 12" PVC WATER 8''x6" SWIVEL TEE w/TB & 6" GV N:136257.71 E:206297.63 FIRE HYDRANT ASSEMBLY N:136261.61 E:206304.83 FIRE HYDRANT ASSEMBLY N:136672.18 E:206504.50 12''x6" SWIVEL TEE w/TB & 6" GV N:136676.96 E:206493.78 30'  -  53' ROW 36'  - 57' ROW 36'  -  57' ROW 16' 16' 16' 16' ROW STREET B STREET B STREET E STREET F STREET F ALLEY 12 ALLEY 13 ALLEY 13 12" PVC WATER 8''x6" SWIVEL TEE w/TB & 6" GV N:136119.45 E:206807.97 FIRE HYDRANT ASSEMBLY N:136124.62 E:206817.97 PARKER LAND INVESTMENTS LLC 9162 KENWOOD CT HIGHLANDS RANCH, CO 801263425 POUDRE SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 36'  -  57' ROW 30'  -  53' ROW 8''x8'' TEE w/TB & 3-8" GV (N,E,W) N:136138.99 E:206906.68 SSMH B8-1 INV. IN=4953.06 (NW) INV. OUT=4952.86 (E) FG=4964.03 FIRE HYDRANT ASSEMBLY N:136068.04 E:206531.61 8''x6" SWIVEL TEE w/TB & 6" GV N:136062.87 E:206521.62 NATURAL HABITAT BUFFER ZONE FES STORM DRAIN INLET (2) STORM DRAIN INLET (2) INLET HEADWALL WITH TRASH RACK FES KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C2.01 UTILITY PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 MATCHLINE-SEE SHEET C2.03 MATCHLINE-SEE SHEET C2.02 13 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R C2.01 C2.02 C2.03 C2.04 C2.05 C2.06 14" W LEGEND: UD 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT (ELCO) STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITARY SEWER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 5. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY EDGE OF GRAVEL EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER PROPOSED UNDERDRAIN PROPOSED RIGHT OF WAY NOTES: EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER EXISTING WATER LINE W PROPOSED 14" WATER LINE PROPOSED 12" WATER LINE 12" W PROPOSED 8" WATER LINE 8" W ELEC H Y F D E S PROPOSED FIRE HYDRANT EXISITNG ELECTRIC BOX EXISTING FIRE HYDRANT EXISTING FES EXISTING WATER VALVE WV PROPOSED BUTTERFLY VALVE PROPOSED WATER VALVE EXISTING STORM SEWER ST W VAULT ELEC V.P. WV VAULT ELEC WV WV WV V.P. ELEC ELEC E GAS T VAULT ELEC VAULT C ELEC SS SS SS SS SS SS E X X X X X X X X X X X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE H Y D G G G G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W T ELE W GAS TELE R R H2O WV WV WV H2O WV WV WV S W SS W W IRR IRR W W W W W W W W W W W W H 2O GAS GAS H2O IRR D D D W W W W W W W W W W W W W W W W W W W W W W W W W W W W 8" W 8" W 14" W 14" W 14" W 8" W 8" W 8" W 8" W 8" W 8" W 14" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 12" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 8" W 12" W 12" W 12" W 12" W 12" W 8" W 12" W 8" W 8" W 8" W UD IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR N YLOPLAST DO NOT POLLUTE DRAINS TO WATERWAYS 8" W 8" W 8" W 8" W 8" W STREET A STREET B STREET B STREET C STREET C STREET C STREET D STREET D STREET E STREET E STREET E STREET F STREET F ALLEY 2 ALLEY 1 ALLEY 3 ALLEY 4 ALLEY 4 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 8 ALLEY 5 ALLEY 6 ALLEY 7 ALLEY 9 ALLEY 9 ALLEY 9 ALLEY 12 ALLEY 10 ALLEY 10 ALLEY 11 ALLEY 13 ALLEY 13 STREET G STREET G STREET H STREET H STREET H ALLEY 15 ALLEY 15 ALLEY 16 ALLEY 16 ALLEY 16 ALLEY 16 ALLEY 17 ALLEY 18 ALLEY 19 ALLEY 20 ALLEY 21 ALLEY 16 ALLEY 22 ALLEY 23 ALLEY 24 ALLEY 25 PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT CONNECT TO EXISTING 14" AC ELCO WATER MAIN CONNECT TO EXISTING 14" ELCO WATER MAIN CONNECT TO EXISTING 12" WATERLINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 8" SANITARY SEWER LINE PROPOSED 12" SANITARY SEWER LINE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 PARKER LAND INVESTMENTS LLC 9162 KENWOOD CT HIGHLANDS RANCH, CO 801263425 WEISS DONALD D/ BEVERLY A 1924 E. VINE DR. FORT COLLINS, CO 80524 POUDRE SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 BULL RUN LTD PARTNERSHIP 5575 DTC PKWY STE 250 GREENWOOD VILLAGE, CO 80111 DIVISION SEVEN SYSTEMS 8 GIBBS RD LARAMIE, WY 80207 OPPIE VERA N PO BOX 302 LAPORTE, CO 80535 K AND M COMPANY PO BOX 449 WEISS DONALD D/ BEVERLY A FORT COLLINS, CO 80522 1924 E. VINE DR. FORT COLLINS, CO 80524 K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 TIMBERVINE FARM LIMITED PARTNERSHIP PO BOX 272546 FORT COLLINS, CO 80527 VOICE OF TRUTH TABERNACLE 1132 SAWTOOTH OAK CT FORT COLLINS, CO 80525 RYK JOE 1506 GLEN HAVEN DR. FORT COLLINS, CO 80526 HOLTER GEORGE A 3509 S MASON ST FORT COLLINS, CO 80525 PLOOG BARRY L PO BOX 967 BOULDER, CO 80306 JONES LEONARD L & ROMA K 2616 E. VINE DR FORT COLLINS, CO 80524 MARK WHITE 132 JENNINGS LN JOHNSTOWN, CO 80534 PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED FIRE HYDRANT PROPOSED 12" WATER PROPOSED 12" WATER PROPOSED 12" WATER CONNECT TO EXISTING BOXELDER SEWER LINE PROPOSED 14" WATER SUNIGA ROAD PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN TRACT O PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN PROPOSED STORM DRAIN CONNECT TO EXISTING BOXELDER SEWER LINE N TIMBERLINE ROAD OLD VINE DRIVE FUTURE REALIGNED N TIMBERLINE ROAD ULTIMATE DISCHARGE LOCATION (TO BE CONSTRUCTED PER WATERFIELD 1ST FILING CONSTRUCTION PLANS) KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C2.00 OVERALL UTILITY PLAN 12 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R NORTH ( IN FEET ) 0 1 INCH = 150 FEET 150 150 300 450 C2.01 C2.02 C2.03 C2.04 C2.05 C2.06 14" W LEGEND: UD 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL WATER CONSTRUCTION SHALL BE PER THE EAST LARIMER COUNTY WATER DISTRICT (ELCO) STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 4. ALL SEWER CONSTRUCTION SHALL BE PER BOXELDER SANITARY SEWER DISTRICT STANDARD CONSTRUCTION SPECIFICATIONS, LATEST EDITION. 5. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 6. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 7. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS & SERVICES. PROPOSED EASEMENT EXISTING RIGHT OF WAY PROPOSED LOT LINE PROPERTY BOUNDARY EDGE OF GRAVEL EXISTING CONTOUR PROPOSED CONTOUR PROPOSED STORM INLET PROPOSED STORM SEWER PROPOSED UNDERDRAIN PROPOSED RIGHT OF WAY NOTES: EXISTING SANITARY SEWER SS PROPOSED SANITARY SEWER EXISTING WATER LINE W PROPOSED 14" WATER LINE PROPOSED 12" WATER LINE 12" W PROPOSED 8" WATER LINE 8" W ELEC H Y F D E S PROPOSED FIRE HYDRANT EXISITNG ELECTRIC BOX EXISTING FIRE HYDRANT EXISTING FES EXISTING WATER VALVE WV PROPOSED BUTTERFLY VALVE PROPOSED WATER VALVE EXISTING STORM SEWER ST TH TH TH X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE H Y D W W W W W W W W W W W W W W W W W W W W W W GAS WV WV WV S W SS SS SS W W W W W W W W W GRADING & STORMWATER DETENTION POND MAINTENANCE EASEMENT REC. NO. 2000049501 TO BE VACATED SCRUB TREE AREA TO BE REMOVED EXISTING SANITARY MH PDI 0820 RIM=4958.17 INV. 10" PVC (N)=4945.64 INV. 10" PVC (S)=4945.40 TO BE REMOVED EXISTING LIGHT POLE TO BE RELOCATED EXISTING SIGN TO BE REMOVED EXISTING SIGNS TO BE REMOVED EXISTING SIGN TO BE REMOVED EXISTING 10" SANITARY SEWER LINE TO BE REMOVED EXISTING CURB, GUTTER, & SIDEWALK TO BE REMOVED EXISTING WATER LINE TO BE REMOVED EXISTING "NO TRESPASSING" SIGN EXISTING SANITARY MH PDI 0750 RIM=4949.29 INV. 10" PVC (E)=4938.24 INV. 16" PVC (S)=4937.99 EXISTING SANITARY MH PDI 0760 RIM=4951.42 INV. 10" PVC (E)=4938.97 INV. 10" PVC (W)=4938.79 EXISTING "GAS PIPELINE WARNING" SIGN EXISTING "MERGANSER DR/VINE DR/ NO OUTLET/STOP" SIGN SCRUB TREE AREA TO BE REMOVED EXISTING STORM MH RIM=4955.64 INV. 60" RCP (NW)=4945.84 INV. 60" RCP (E)=4945.84 EXISTING SANITARY MH PDI 0770 RIM=4955.19 INV. 10" PVC (N)=4940.04 INV. 10" PVC (W)=4939.82 EXISTING STORM MH RIM=4954.86 INV. 60" RCP (NW)=4938.97 INV. 60" RCP (SE)=4938.79 INV. 60" RCP=4945.44 EXISTING SANITARY MH PDI 0780 RIM=4956.50 INV. 10" PVC (N)=4940.43 INV. 8" PVC (W)=4940.53 INV. 10" PVC (S)=4940.22 SCRUB TREE AREA TO BE REMOVED SCRUB TREE AREA TO BE REMOVED EXISTING SANITARY MH PDI 0790 RIM=4957.43 INV. 10" PVC (N)=4941.13 INV. 10" PVC (S)=4940.92 EXISTING SANITARY MH PDI 0800 RIM=4958.36 INV. 10" PVC (N)=4941.99 INV. 10" PVC (E)=4941.99 INV. 10" PVC (S)=4941.89 TO BE REMOVED & REPLACED EXISTING ELECTRIC BOX EXISTING GAS MARKER EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC VAULT (TO BE RELOCATED) EXISTING ELECTRIC METER EXISTING LIGHT POLE EXISTING ELECTRIC VAULT TO BE RELOCATED EXISTING SIGNS TO BE REMOVED EXISTING SIGN TO BE REMOVED EXISTING SIGNS TO BE REMOVED EXISTING SIGN TO BE REMOVED EXISTING 10" SANITARY SEWER LINE EXISTING 10" SANITARY SEWER LINE EXISTING OVERHEAD ELECTRICAL LINE TO BE RELOCATED UNDERGROUND EXISTING CABLE VAULT EXISTING LIGHT POLE EXISTING WATER MANHOLE TO BE REMOVED EXISTING 16" SANITARY SEWER LINE EXISTING ELECTRIC VAULT TO BE RELOCATED EXISTING OVERHEAD ELECTRICAL LINE TO BE RELOCATED UNDERGROUND EXISTING TELEPHONE MANHOLE EXISTING CURB, GUTTER, & SIDEWALK TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING 2' TRICKLE PAN TO BE REMOVED EXISTING WATER LINE TO BE REMOVED EXISTING FIRE HYDRANT EXISTING POWER POLE TO BE REMOVED EXISTING POWER POLE TO BE REMOVED EXISTING 8" SS LINE TO BE REMOVED EXISTING MH TO BE GROUTED PER BOXELDER SANITATION DISTRICT STANDARDS SANITARY SEWER LINE TO BE REMOVED CONTRACTOR TO COORDINATE WITH PRIVATE UTILITY COMPANIES. EXISTING UTILITIES MAY REQUIRE TO BE RELOCATED. STORM LINE TO BE REMOVED APPROXIMATELY 60' DIVISION SEVEN SYSTEMS 8 GIBBS RD LARAMIE, WY 80207 BULL RUN LTD PARTNERSHIP 5575 DTC PKWY STE 250 GREENWOOD VILLAGE, CO 80111 OPPIE VERA N PO BOX 302 LAPORTE, CO 80535 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING SANITARY MH PDI 0810 RIM=4958.96 INV. 10" PVC (N)=4942.24 INV. 8" PVC (W)=4942.36 INV. 10" PVC (S)=4942.15 TO BE REMOVED END ELECTRIC LINE UNDERGROUNDING Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C1.07 DEMOLITION PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 MATCHLINE-SEE SHEET C1.06 MATCHLINE-SEE SHEET C1.04 MATCHLINE-SEE SHEET C1.05 MATCHLINE-SEE SHEET C1.04 11 C1.02 C1.03 C1.04 C1.05 C1.06 C1.07 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: G OHE OHE EXISTING STORM SEWER ST EXISTING OVERHEAD ELECTRIC LINES EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL NOTES: 1. IR STANDARDS. EXISTING CP TEST STATIONS TO BE RELOCATED OUT OF ASPHALT SECTION LOCATED BEHIND BACK OF CURB. CONTRACTOR TO COTACT CITY OF FORT COLLINS WATER UTILITIES (970) 416-2165 TO CORDINATE THE RELOCATION PRIOR TO GRADING AND PAVING ALONG TIMBERLINE ROAD. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR ELEC F E S GV C S W GAS H2O H2O S D TH WV V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL ROAD ROW LINE EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER STUB EXISTING GATE VALVE EXISTING FLARED END SECTION EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING GAS MARKER EXISTING WATER MARKER EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING TESTHOLE EXISTING POWER POLE EXISTING VERTICAL PIPE SECTION LINE EXISTING UTILITIES TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING CONCRETE TO BE REMOVED G G G W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W CENTER OF WATER LINE RIGHT-OF-WAY OF UNDEFINED WIDTH BOOK 737, PAGE 575 CENTER OF CITY OF GREELEY PIPELINE EASEMENT BK 951, PG 115 & BK 1465, PG 452 50' GAS LINE EASEMENT WESTERN SLOPE GAS COMPANY BOOK 1380, PAGE 222 (PUBLIC SERVICE CO.) BOXELDER SANITATION DISTRICT SEWER EASEMENT REC. NO. 98090191 TO BE VACATED GRADING & STORMWATER DETENTION POND MAINTENANCE EASEMENT REC. NO. 2000049501 TO BE VACATED EXISTING "WARNING NATURAL GAS PIPELINE PIPELINE NOT UNDER MARKER" SIGN EXISTING 8' CHAINLINK FENCE EXISTING "CITY OF GREELEY BURIED PIPELINE #1" SIGN EXISTING "CITY OF GREELEY BURIED PIPELINE #3" SIGN EXISTING 2' TRICKLE PAN TO BE REMOVED EXISTING OUTLET STRUCTURE INV.=4940.9 TO BE REMOVED EXISTING STORM MH RIM=4944.42 (TO BE REMOVED) INV. 18" RCP (NE)=4940.92 INV. 24" RCP (SW)=4940.87 EXISTING "NO TRESPASSING NO DUMPING" SIGN EXISTING "BIKE LANE ENDS" SIGN (TO BE RELOCATED) EXISTING "FUTURE PARK" SIGN (TO BE REMOVED) EXISTING "PROPOSED SCHOOL SITE" SIGN (TO BE REMOVED) EXISTING "ROAD NARROWS" SIGN (TO BE RELOCATED) EXISTING "GAS PIPELINE WARNING" SIGN EXISTING "NO TRESPASSING" SIGN EXISTING SANITARY MH PDI 0750 RIM=4949.29 INV. 10" PVC (E)=4938.24 INV. 16" PVC (S)=4937.99 EXISTING OVERFLOW STRUCTURE INV. 12" PVC=4941.10 INV. 12" PVC=4941.15 EXISTING CABLE VAULT EXISTING TESTHOLE EXISTING 10" SANITARY SEWER LINE EXISTING OVERHEAD ELECTRICAL LINE TO BE RELOCATED UNDERGROUND EXISTING POWER POLE TO BE REMOVED EXISTING 16" SANITARY SEWER LINE EXISTING 14" AC PIPE ELCO WATER MAIN EXISTING GAS FACILITY EXISTING 14" AC PIPE ELCO WATER MAIN TO BE REMOVED EXISTING POWER POLE TO BE REMOVED EXISTING OVERHEAD ELECTRICAL LINE TO BE RELOCATED UNDERGROUND EXISTING OVERHEAD ELECTRICAL LINE 76 L.F. OF EXISTING 18" RCP TO BE REMOVED EXISTING WATER LINE TO BE REMOVED WEISS DONALD D/ BEVERLY A 1924 E. VINE DR. FORT COLLINS, CO 80524 CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / INV. 24" RCP=4941.35 BEGIN ELECTRIC LINE UNDERGROUNDING Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C1.06 DEMOLITION PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 MATCHLINE-SEE SHEET C1.04 MATCHLINE-SEE SHEET C1.07 10 C1.02 C1.03 C1.04 C1.05 C1.06 C1.07 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: G OHE OHE EXISTING STORM SEWER ST EXISTING OVERHEAD ELECTRIC LINES EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL NOTES: 1. IR STANDARDS. EXISTING CP TEST STATIONS TO BE RELOCATED OUT OF ASPHALT SECTION LOCATED BEHIND BACK OF CURB. CONTRACTOR TO COTACT CITY OF FORT COLLINS WATER UTILITIES (970) 416-2165 TO CORDINATE THE RELOCATION PRIOR TO GRADING AND PAVING ALONG TIMBERLINE ROAD. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR ELEC F E S GV C S W GAS H2O H2O S D TH WV V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL ROAD ROW LINE EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER STUB EXISTING GATE VALVE EXISTING FLARED END SECTION EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING GAS MARKER EXISTING WATER MARKER EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING TESTHOLE EXISTING POWER POLE EXISTING VERTICAL PIPE SECTION LINE EXISTING UTILITIES TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING CONCRETE TO BE REMOVED OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE H Y D W W W W W W W W W W W D TELE WV WV WV S W SS SS SS IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR W W W W W W W W W W W W W W W W W W W W W W H 2O GAS GAS IRR IRR IRR IRR D V.P. V.P. EXISTING SANITARY MH PDI 0820 RIM=4958.17 INV. 10" PVC (N)=4945.64 INV. 10" PVC (S)=4945.40 TO BE REMOVED EXISTING LIGHT POLE TO BE RELOCATED EXISTING SIGN TO BE REMOVED EXISTING 10" SANITARY SEWER LINE TO BE REMOVED SCRUB TREE AREA TO BE REMOVED EXISTING 18" CMP INV.=4970.59 TO BE REMOVED EXISTING 18" CMP INV.=4970.45 TO BE REMOVED EXISTING 8" STEEL PIPE (CUT OFF) TO BE REMOVED EXISTING 6" STEEL PIPE (CUT OFF) TO BE REMOVED EXISTING 6-2" PVC VERT. PIPES TO BE REMOVED EXISTING 8" PLASTIC PIPE (ABOVE GROUND) TO BE REMOVED EXISTING PUMP HOUSE EXISTING SANITARY MH PDI 0790 RIM=4957.43 INV. 10" PVC (N)=4941.13 INV. 10" PVC (S)=4940.92 EXISTING SANITARY MH PDI 0800 RIM=4958.36 INV. 10" PVC (N)=4941.99 INV. 10" PVC (E)=4941.99 INV. 10" PVC (S)=4941.89 TO BE REMOVED & REPLACED EXISTING ELECTRIC VAULT EXISTING ELECTRIC BOX EXISTING ELECTRIC BOX TO BE RELOCATED BY OTHERS EXISTING ELECTRIC BOX EXISTING GAS MARKER EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC VAULT (TO BE RELOCATED) EXISTING ELECTRIC METER EXISTING LIGHT POLE EXISTING POWER POLE TO BE REMOVED EXISTING TESTHOLE EXISTING OVERHEAD ELECTRICAL LINE TO BE RELOCATED UNDERGROUND EXISTING WATER MANHOLE TO BE REMOVED EXISTING FIRE HYDRANT EXISTING POWER POLE TO BE REMOVED EXISTING POWER POLE TO BE REMOVED EXISTING POWER POLE TO BE REMOVED EXISTING CONCRETE TO BE REMOVED SANITARY SEWER LINE TO BE REMOVED EXISTING 18" CMP INV.=4972.22 TO BE REMOVED EXISTING IRRIGATION MANHOLE TO BE REMOVED IRRIGATION LINE TO THE SOUTH TO BE REMOVED AND CAPPED AT NEXT MANHOLE CONTRACTOR TO COORDINATE WITH PRIVATE UTILITY COMPANIES. EXISTING UTILITIES MAY REQUIRE TO BE RELOCATED. APPROXIMATE LOCATION OF BURIED CP TEST STATION TO BE RELOCATED NOT FIELD LOCATION (SEE NOTE 1) BULL RUN LTD PARTNERSHIP 5575 DTC PKWY STE 250 GREENWOOD VILLAGE, CO 80111 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / END ELECTRIC LINE UNDERGROUNDING EXISTING SANITARY MH PDI 0810 RIM=4958.96 INV. 10" PVC (N)=4942.24 INV. 8" PVC (W)=4942.36 INV. 10" PVC (S)=4942.15 TO BE REMOVED EXISTING ELECTRIC VAULT TO BE RELOCATED N TIMBERLINE ROAD Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C1.05 DEMOLITION PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 MATCHLINE-SEE SHEET C1.07 MATCHLINE-SEE SHEET C1.03 MATCHLINE-SEE SHEET C1.04 09 C1.02 C1.03 C1.04 C1.05 C1.06 C1.07 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: G OHE OHE EXISTING STORM SEWER ST EXISTING OVERHEAD ELECTRIC LINES EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL NOTES: 1. IR STANDARDS. EXISTING CP TEST STATIONS TO BE RELOCATED OUT OF ASPHALT SECTION LOCATED BEHIND BACK OF CURB. CONTRACTOR TO COTACT CITY OF FORT COLLINS WATER UTILITIES (970) 416-2165 TO CORDINATE THE RELOCATION PRIOR TO GRADING AND PAVING ALONG TIMBERLINE ROAD. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR ELEC F E S GV C S W GAS H2O H2O S D TH WV V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL ROAD ROW LINE EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER STUB EXISTING GATE VALVE EXISTING FLARED END SECTION EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING GAS MARKER EXISTING WATER MARKER EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING TESTHOLE EXISTING POWER POLE EXISTING VERTICAL PIPE SECTION LINE EXISTING UTILITIES TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING CONCRETE TO BE REMOVED BE REMOVED EXISTING SIGN TO BE REMOVED EXISTING 10" SANITARY SEWER LINE TO BE REMOVED EXISTING CURB, GUTTER, & SIDEWALK TO BE REMOVED SCRUB TREE AREA TO BE REMOVED SCRUB TREE AREA EXISTING FENCE TO BE REMOVED EXISTING GAS MARKER EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC VAULT (TO BE RELOCATED) EXISTING ELECTRIC METER EXISTING FENCE TO BE REMOVED EXISTING FENCE TO BE REMOVED EXISTING WATER MANHOLE TO BE REMOVED EXISTING FENCE TO BE REMOVED CITY OF FORT COLLINS 300 LAPORTE AVE FORT COLLINS, CO 80521 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING SANITARY MH PDI 0810 RIM=4958.96 INV. 10" PVC (N)=4942.24 INV. 8" PVC (W)=4942.36 INV. 10" PVC (S)=4942.15 TO BE REMOVED CONTRACTOR TO VERIFY IF SUBDRAIN IS STILL IN. IF STILL IN PLACE CONTRACTOR TO REMOVE THE ENTIRE SUBDRAIN Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C1.04 DEMOLITION PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 MATCHLINE-SEE SHEET C1.06 MATCHLINE-SEE SHEET C1.03 MATCHLINE-SEE SHEET C1.02 MATCHLINE-SEE SHEET C1.07 MATCHLINE-SEE SHEET C1.05 08 C1.02 C1.03 C1.04 C1.05 C1.06 C1.07 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: G OHE OHE EXISTING STORM SEWER ST EXISTING OVERHEAD ELECTRIC LINES EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL NOTES: 1. IR STANDARDS. EXISTING CP TEST STATIONS TO BE RELOCATED OUT OF ASPHALT SECTION LOCATED BEHIND BACK OF CURB. CONTRACTOR TO COTACT CITY OF FORT COLLINS WATER UTILITIES (970) 416-2165 TO CORDINATE THE RELOCATION PRIOR TO GRADING AND PAVING ALONG TIMBERLINE ROAD. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR ELEC F E S GV C S W GAS H2O H2O S D TH WV V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL ROAD ROW LINE EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER STUB EXISTING GATE VALVE EXISTING FLARED END SECTION EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING GAS MARKER EXISTING WATER MARKER EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING TESTHOLE EXISTING POWER POLE EXISTING VERTICAL PIPE SECTION LINE EXISTING UTILITIES TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING CONCRETE TO BE REMOVED V.P. V.P. 20' SUBDRAIN EASEMENT REC. NO. 2000049500 TO BE VACATED EXISTING CONCRETE DIVERSION STRUCTURE TO BE REMOVED EXISTING 18" RCP INV.=4970.61 TO BE REMOVED EXISTING 18" RCP INV.=4970.29 TO BE REMOVED EXISTING 24"x24" BOX CULVERT INV.=4973.16 EXISTING SCRUB TREE AREA (TO BE REMOVED) SCRUB TREE AREA TO BE REMOVED EXISTING 18" CMP INV.=4970.59 TO BE REMOVED EXISTING 18" CMP INV.=4970.45 TO BE REMOVED EXISTING 18" CMP INV.=4974.20 TO BE REMOVED EXISTING 10' WIDE GRAVEL ROADWAY TO BE REMOVED EXISTING 8" STEEL PIPE (CUT OFF) TO BE REMOVED EXISTING 6" STEEL PIPE (CUT OFF) TO BE REMOVED EXISTING 6-2" PVC VERT. PIPES TO BE REMOVED EXISTING 8" PLASTIC PIPE (ABOVE GROUND) TO BE REMOVED EXISTING POWER POLE EXISTING ELECTRIC BOX TO BE RELOCATED BY OTHERS EXISTING VERTICAL PIPE EXISTING TESTHOLE EXISTING OVERHEAD ELECTRICAL LINE TO BE RELOCATED UNDERGROUND HEADGATE NO. 10 LATERAL EXISTING FENCE TO BE REMOVED EXISTING FENCE EXISTING POWER POLE EXISTING POWER POLE TO BE REMOVED EXISTING POWER POLE TO BE REMOVED EXISTING POWER POLE TO BE REMOVED EXISTING POWER POLE TO BE REMOVED EXISTING CONCRETE TO BE REMOVED EXISTING 18" CMP INV.=4972.22 TO BE REMOVED APPROXIMATE LOCATION OF BURIED CP TEST STATION TO BE RELOCATED NOT FIELD LOCATION (SEE NOTE 1) APPROXIMATE LOCATION OF BURIED CP TEST STATION TO BE RELOCATED NOT FIELD LOCATION (SEE NOTE 1) K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / N TIMBERLINE ROAD BEGIN ELECTRIC LINE UNDERGROUNDING Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C1.03 DEMOLITION PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 MATCHLINE-SEE SHEET C1.05 MATCHLINE-SEE SHEET C1.04 MATCHLINE-SEE SHEET C1.02 07 C1.02 C1.03 C1.04 C1.05 C1.06 C1.07 LEGEND: G OHE OHE EXISTING STORM SEWER ST EXISTING OVERHEAD ELECTRIC LINES EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL NOTES: 1. IR STANDARDS. EXISTING CP TEST STATIONS TO BE RELOCATED OUT OF ASPHALT SECTION LOCATED BEHIND BACK OF CURB. CONTRACTOR TO COTACT CITY OF FORT COLLINS WATER UTILITIES (970) 416-2165 TO CORDINATE THE RELOCATION PRIOR TO GRADING AND PAVING ALONG TIMBERLINE ROAD. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR ELEC F E S GV C S W GAS H2O H2O S D TH WV V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL ROAD ROW LINE EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER STUB EXISTING GATE VALVE EXISTING FLARED END SECTION EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING GAS MARKER EXISTING WATER MARKER EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING TESTHOLE EXISTING POWER POLE EXISTING VERTICAL PIPE SECTION LINE EXISTING UTILITIES TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING CONCRETE TO BE REMOVED CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W 75' 20' WATERLINE EASEMENT EAST LARIMER COUNTY WATER DISTRICT BOOK 1873, PAGE 126 25' RIGHT-OF-WAY LARIMER AND WELD COUNTY CANAL BOOK 1503, PAGE 676 40' EAST LARIMER COUNTY WATER DISTRICT RIGHT OF WAY EASEMENT REC. NO. 20080072495 20' CITY OF FORT COLLINS WATER MAIN EASEMENT RECEPTION NO. 85054353 20' ELCO EASEMENT & RIGHT-OF-WAY EXISTING CONCRETE DIVERSION STRUCTURE TO BE REMOVED EXISTING 36" CMP INV.=4972.13 TO BE REMOVED EXISTING 36" CMP INV.=4972.36 TO BE REMOVED EXISTING "CITY OF FORT COLLINS BURRIED PIPELINE" SIGN EXISTING CONCRETE DIVERSION STRUCTURE TO BE REMOVED EXISTING 18" RCP INV.=4970.61 TO BE REMOVED EXISTING FENCE TO BE REMOVED CENTERLINE ELECTRIC TRANSMISSION LINE EASEMENT EXISTING TESTHOLE EXISTING OVERHEAD ELECTRICAL LINE EXISTING WATER MANHOLE EXISTING POWER POLE EXISTING WATER MANHOLE EXISTING VERTICAL PIPE EXISTING CITY OF FORT COLLINS WATER LINE EXISTING 24" DUCTILE IRON PIPE EAST LARMIER COUNTY WATER DISTRICT (ELCO) WATER LINE EXISTING 42" DUCTILE IRON PIPE NORTH WELD COUNTY WATER DISTRICT (NWCWD) & ELCO WATER LINE EXISTING FENCE TO BE REMOVED EXISTING "CITY OF FORT COLLINS BURIED PIPELINE" SIGNS EXISTING "ELCO WATER LINE" SIGN PARKER LAND INVESTMENTS LLC 9162 KENWOOD CT HIGHLANDS RANCH, CO 801263425 POUDRE SCHOOL DISTRICT 2407 LAPORTE AVE FORT COLLINS, CO 80521 K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 K AND M COMPANY PO BOX 449 FORT COLLINS, CO 80522 / / / / / / / / / / / / / / / / Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR C1.02 DEMOLITION PLAN NORTH ( IN FEET ) 0 1 INCH = 50 FEET 50 50 100 150 MATCHLINE-SEE SHEET C1.04 MATCHLINE-SEE SHEET C1.03 06 C1.02 C1.03 C1.04 C1.05 C1.06 C1.07 LEGEND: G OHE OHE EXISTING STORM SEWER ST EXISTING OVERHEAD ELECTRIC LINES EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL NOTES: 1. IR STANDARDS. EXISTING CP TEST STATIONS TO BE RELOCATED OUT OF ASPHALT SECTION LOCATED BEHIND BACK OF CURB. CONTRACTOR TO COTACT CITY OF FORT COLLINS WATER UTILITIES (970) 416-2165 TO CORDINATE THE RELOCATION PRIOR TO GRADING AND PAVING ALONG TIMBERLINE ROAD. EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR ELEC F E S GV C S W GAS H2O H2O S D TH WV V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL ROAD ROW LINE EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER STUB EXISTING GATE VALVE EXISTING FLARED END SECTION EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING GAS MARKER EXISTING WATER MARKER EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING TESTHOLE EXISTING POWER POLE EXISTING VERTICAL PIPE SECTION LINE EXISTING UTILITIES TO BE REMOVED / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING CONCRETE TO BE REMOVED CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R ELEC VAULT C ELEC SS SS SS SS SS SS SS SS SS SS SS SS E E T H TH TH TH TH TH TH TH TH TH TH X X X X X X X X X X X X X X X X X X X X X X OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE H Y D G G G G G G G G G G G G W W W W W W W W W W W T ELE W GAS D TELE R R R R H2O WV WV WV H2O WV WV WV S W SS W W W W IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR IRR W W W W W W W W W W W W W W W W H2O GAS GAS IRR IRR D D D W W W W W W W W W W W W W W W W W W W W W W W W W W V .P. V.P. SCRUB TREE AREA SCRUB TREE AREA SCRUB TREE AREA EXISTING 18" CMP INV.=4970.59 EXISTING 18" CMP INV.=4970.45 EXISTING 8" STEEL PIPE (CUT OFF) EXISTING 6" STEEL PIPE (CUT OFF) EXISTING 6-2" PVC VERT. PIPES EXISTING 8" PLASTIC PIPE (ABOVE GROUND) EXISTING PUMP HOUSE 50' GAS LINE EASEMENT WESTERN SLOPE GAS COMPANY BOOK 1380, PAGE 222 (PUBLIC SERVICE CO.) BOXELDER SANITATION DISTRICT SEWER EASEMENT REC. NO. 98090191 GRADING & STORMWATER DETENTION POND MAINTENANCE EASEMENT REC. NO. 2000049501 EXISTING XCEL SIGN "WARNING NATURAL GAS PIPELINE PIPELINE NOT UNDER MARKER" EXISTING 8' CHAINLINK FENCE EXISTING "CITY OF GREELEY BURIED PIPELINE #1" SIGN EXISTING "CITY OF GREELEY BURIED PIPELINE #3" SIGN EXISTING 2' TRICKLE PAN EXISTING 18" RCP INV.=4940.9 EXISTING STORM MH RIM=4944.42 INV. 18" RCP (NE)=4940.92 EXISTING INV. 24" RCP (SW)=4940.87 "NO TRESPASSING NO DUMPING" SIGN EXISTING "BIKE LANE ENDS" SIGN EXISTING "FUTURE PARK" SIGN EXISTING "PROPOSED SCHOOL SITE" SIGN EXISTING "ROAD NARROWS" SIGN EXISTING "GAS PIPELINE WARNING" SIGN EXISTING "NO TRESPASSING" SIGN EXISTING SANITARY MH PDI 0750 RIM=4949.29 INV. 10" PVC (E)=4938.24 INV. 16" PVC (S)=4937.99 EXISTING SANITARY MH PDI 0760 RIM=4951.42 INV. 10" PVC (E)=4938.97 INV. 10" PVC (W)=4938.79 EXISTING "GAS PIPELINE WARNING" SIGN EXISTING "MERGANSER DR/VINE DR/ NO OUTLET/STOP" SIGN SCRUB TREE AREA EXISTING STORM MH RIM=4955.64 INV. 60" RCP (NW)=4945.84 INV. 60" RCP (E)=4945.84 EXISTING SANITARY MH PDI 0770 RIM=4955.19 INV. 10" PVC (N)=4940.04 INV. 10" PVC (W)=4939.82 EXISTING STORM MH RIM=4954.86 INV. 60" RCP (NW)=4938.97 INV. 60" RCP (SE)=4938.79 INV. 60" RCP=4945.44 EXISTING SANITARY MH PDI 0780 RIM=4956.50 INV. 10" PVC (N)=4940.43 INV. 8" PVC (W)=4940.53 INV. 10" PVC (S)=4940.22 SCRUB TREE AREA SCRUB TREE AREA SCRUB TREE AREA EXISTING SANITARY MH PDI 0790 RIM=4957.43 INV. 10" PVC (N)=4941.13 INV. 10" PVC (S)=4940.92 EXISTING SANITARY MH PDI 0800 RIM=4958.36 INV. 10" PVC (N)=4941.66 INV. 10" PVC (E)=4941.74 INV. 10" PVC (S)=4940.41 EXISTING SANITARY MH PDI 0810 RIM=4958.96 INV. 10" PVC (N)=4942.24 INV. 8" PVC (W)=4942.36 INV. 10" PVC (S)=4942.15 EXISTING SANITARY MH PDI 0820 RIM=4958.17 INV. 10" PVC (N)=4945.64 INV. 10" PVC (S)=4945.40 EXISTING OVERFLOW STRUCTURE EXISTING ELECTRIC VAULT EXISTING ELECTRIC BOX EXISTING ELECTRIC BOX EXISTING ELECTRIC BOX EXISTING GAS MARKER EXISTING TELEPHONE PEDESTAL EXISTING ELECTRIC VAULT EXISTING LIGHT POLE EXISTING SIGN EXISTING ELECTRIC METER EXISTING SIGN EXISTING SIGN EXISTING LIGHT POLE EXISTING ELECTRIC VAULT EXISTING SIGN EXISTING SIGN EXISTING SIGN EXISTING 12" ELCO WATER INV. 24" RCP=4941.35 INV. 12" PVC=4941.10 INV. 12" PVC=4941.15 EXISTING FENCE EXISTING FENCE EXISTING POWER POLE EXISTING TESTHOLE EXISTING TESTHOLE EXISTING OVERHEAD ELECTRICAL LINE EXISTING 10" SANITARY SEWER LINE EXISTING 10" SANITARY SEWER LINE EXISTING 10" SANITARY SEWER LINE EXISTING ELECTRICAL LINE EXISTING CABLE VAULT EXISTING POWER POLE EXISTING LIGHT POLE HEADGATE NO. 10 LATERAL EXISTING "EXCEL GAS LINE" SIGN EXISTING 14" AC PIPE ELCO WATER LINE EXISTING 24" CITY OF GREELEY WATER PIPELINE #1 EXISTING CABLE VAULT EXISTING XCEL GAS FACILITY EXISTING SIGN EXISTING 10" BOXELDER SANITATION DISTRICT SANITARY SEWER MAIN WETLAND BOUNDARY (DELINEATED BY CEDAR CREEK) PERMANENT WATER SURFACE APPROX. LOCATION OF EXISTING ELCO WATER MAIN APPROX. LOCATION OF EXISTING ELCO WATER MAIN EXISTING STORM SEWER INLET EXISTING STORM SEWER INLET EXISTING 14" AC ELCO WATER MAIN OLD VINE DRIVE N TIMBERLINE ROAD MERGANSER BULL RUN APARTMENTS APPROXIMATE LOCATION OF EXISTING IRRIGATION LINE EXISTING IRRIGATION MANHOLE EXISTING IRRIGATION MANHOLE EXISTING IRRIGATION MANHOLE EXISTING IRRIGATION MANHOLE EXISTING SIDEWALK EXISTING 24" WATER MAIN CITY OF FORT COLLINS CENTER OF WATER LINE RIGHT-OF-WAY OF UNDEFINED WIDTH BOOK 737, PAGE 575 CENTER OF CITY OF GREELEY PIPELINE EASEMENT BK 951, PG 115 & BK 1465, PG 452 CENTERLINE OF 15' WATERLINE EASEMENT EAST LARIMER COUNTY WATER DISTRICT BOOK 1740, PAGE 896 20' SUBDRAIN EASEMENT REC. NO. 2000049500 TO BE VACATED Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C1.01 EXISTING CONDITIONS PLAN KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR NORTH ( IN FEET ) 0 1 INCH = 100 FEET 100 100 200 300 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: G OHE OHE EXISTING STORM SEWER ST EXISTING OVERHEAD ELECTRIC LINES EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. ORIGINAL FIELD SURVEY BY: NORTHERN ENGINEERING SERVICES, INC. PROJECT NUMBER: 889-003 DATE: JUNE 13, 2013 EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR A.G. WASSENAAR INC. "GEOTECHNICAL SITE DEVELOPMENT STUDY WATERFIELD DEVELOPMENT NOTHWEST OF EAST VINE DRIVE AND NORTH TIMBERLINE ROAD" PROJECT NUMBER: 131041 DATE: JUNE 12, 2013 ELEC F E S GV C S W GAS H2O H2O S D TH WV V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL ROAD CENTERLINE EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER STUB EXISTING GATE VALVE EXISTING FLARED END SECTION EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING GAS MARKER EXISTING WATER MARKER EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING TESTHOLE EXISTING POWER POLE EXISTING VERTICAL PIPE ADDITIONAL FIELD SURVEYS: NORTHERN ENGINEERING SERVICES, INC. DATE: JULY 27, 2013 C1.00 C1.01 05 OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE G G G G G G G G G G G G G G G W W W W W W W W W W W W W W W W W W W W W W W W W W W W H2O W W W W W W W W W W W W W W W W W W W W W W W W W W EXISTING EXCEL SIGN "WARNING NATURAL GAS PIPELINE PIPELINE NOT UNDER MARKER" EXISTING CONCRETE DIVERSION STRUCTURE (TO BE REMOVED) EXISTING 36" CMP INV.=4972.13 EXISTING 36" CMP INV.=4972.36 EXISTING "CITY OF FORT COLLINS BURIED PIPELINE" SIGN EXISTING HEADWALL W/ GATE VALVE EXISTING RCP INV.=4972.64 EXISTING TOP OF 14" ELCO WATER LINE EXISTING TOP OF 8" EXCEL GAS LINE EXISTING CONCRETE DIVERSION STRUCTURE EXISTING 18" RCP INV.=4970.61 EXISTING 18" RCP INV.=4970.29 EXISTING HEADGATE NO. 10 24"x24" BOX CULVERT INV.=4973.16 SCRUB TREE AREA EXISTING 18" CMP INV.=4970.59 EXISTING 18" CMP INV.=4974.20 EXISTING 10' WIDE GRAVEL ROADWAY EXISTING FENCE 50' GAS LINE EASEMENT WESTERN SLOPE GAS COMPANY BOOK 1380, PAGE 222 (PUBLIC SERVICE CO.) 75' 20' WATERLINE EASEMENT EAST LARIMER COUNTY WATER DISTRICT BOOK 1873, PAGE 126 25' RIGHT-OF-WAY LARIMER AND WELD COUNTY CANAL BOOK 1503, PAGE 676 20' SUBDRAIN EASEMENT REC. NO. 2000049500 TO BE VACATED 40' EAST LARIMER COUNTY WATER DISTRICT RIGHT OF WAY EASEMENT REC. NO. 20080072495 20' CITY OF FORT COLLINS WATER MAIN EASEMENT RECEPTION NO. 85054353 20' ELCO EASEMENT & RIGHT-OF-WAY CENTERLINE ELECTRIC TRANSMISSION LINE EASEMENT EXCEL GAS SIGN "WARNING NATURAL GAS PIPELINE PIPELINE NOT UNDER MARKER" EXISTING SIGN "CITY OF FORT COLLINS BURIED PIPELINE" EXISTING POWER POLE EXISTING WATER LINE GATE VALVE EXISTING TESTHOLE EXISTING VERTICAL PIPE EXISTING OVERHEAD ELECTRICAL LINE EXISTING OVERHEAD ELECTRICAL LINE EXISTING FIRE HYDRANT EXISTING WATER METER EXISTING WATER LINE GATE VALVE EXISTING WATER MANHOLE EXISTING WATER MANHOLE EXISTING POWER POLE EXISTING WATER MANHOLE EXISTING VERTICAL PIPE EXISTING WATER MANHOLE EXISTING "NORTH WELD COUNTY WATER DISTRICT" SIGN EXISTING 42" DUCTILE IRON PIPE NORTH WELD COUNTY WATER DISTRICT (NWCWD) & ELCO WATER LINE EXISTING 24" DUCTILE IRON PIPE EAST LARIMER COUNTY WATER DISTRICT (ELCO) WATER LINE EXISTING CITY OF FORT COLLINS WATER LINE LARIMER & WELD CANAL DITCH ROAD HEADGATE NO. 10 LATERAL EXISTING "CITY OF FORT COLLINS BURIED PIPELINE" SIGN EXISTING "ELCO WATER" SIGN EXISTING "ELCO WATER" SIGN WETLAND BOUNDARY (DELINEATED BY CEDAR CREEK) EXISTING EDGE OF GRAVEL DITCH ACCESS ROAD N TIMBERLINE EXISTING 24" WATER MAIN CITY OF FORT COLLINS Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C1.00 EXISTING CONDITIONS PLAN KEYMAP R R SUNIGA DRIVE N SUMMITVIEW DR NORTH ( IN FEET ) 0 1 INCH = 100 FEET 100 100 200 300 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: G OHE OHE EXISTING STORM SEWER ST EXISTING OVERHEAD ELECTRIC LINES EXISTING GAS EXISTING IRRIGATION BOX EXISTING GAS METER EXISTING TELEPHONE PEDESTAL FIELD SURVEY BY: SUBSURFACE EXPLORATION BY: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. ORIGINAL FIELD SURVEY BY: NORTHERN ENGINEERING SERVICES, INC. PROJECT NUMBER: 889-003 DATE: JUNE 13, 2013 EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROJECT BOUNDARY EXISTING LOT, TRACT & ROW LINES FROM PLAT EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR VAULT ELEC CONTROL IRR A.G. WASSENAAR INC. "GEOTECHNICAL SITE DEVELOPMENT STUDY WATERFIELD DEVELOPMENT NOTHWEST OF EAST VINE DRIVE AND NORTH TIMBERLINE ROAD" PROJECT NUMBER: 131041 DATE: JUNE 12, 2013 ELEC F E S GV C S W GAS H2O H2O S D TH WV V.P. EXISTING EASEMENT LINE EDGE OF GRAVEL ROAD CENTERLINE EXISTING INLET GRATE EXISTING WATER CURBSTOP EXISTING WATER STUB EXISTING GATE VALVE EXISTING FLARED END SECTION EXISTING WATER VALVE EXISTING ELECTRIC BOX EXISTING LIGHT POLE EXISTING GAS MARKER EXISTING WATER MARKER EXISTING WATER MANHOLE EXISTING SANITARY MANHOLE EXISTING STORM MANHOLE EXISTING SIGN EXISTING TESTHOLE EXISTING POWER POLE EXISTING VERTICAL PIPE ADDITIONAL FIELD SURVEYS: NORTHERN ENGINEERING SERVICES, INC. DATE: JULY 27, 2013 C1.00 C1.01 04 Walk 4.5' Pkwy 7.5' 4.5' Walk 56' Roadway 8' 80' ROW 18' Travel 20' Median Pkwy. 7.5' Setback Min. Fence 9' Esmt. Util. Util. Esmt. 9' Center 16' 7' PARK TRAVEL 7' PARK 7' (MIN.) PKWY 30' ROADWAY 53' ROW (MIN) WALK 4.5' 6'.5 Min. Fence Setback UTIL. ESMT. 9' 9' UTIL. ESMT. (MIN.) PKWY 7' WALK (MIN) 4.5' 10' 10' 10' 8' TRAVEL PARK TRAVEL 8' PARK TRAVEL TURN 13' TRAVEL 13' LEFT (MIN.) PKWY 36' ROADWAY 60' ROW (MIN) WALK 4.5' 6.5' MIN. FENCE SETBACK UTIL. ESMT. 9' 9' UTIL. ESMT. 36' ROADWAY (MIN) WALK 4.5' (MIN.) PKWY 7.5' 18' Travel TRAVEL 11' 50' ROADWAY TRAVEL 76' ROW 11' 7' 12' TRAVEL LN. TRAVEL BIKE LEFT TURN 12' WALK 4.5' 6.5' PKWY 7' LN. BIKE 12' 9' 7' MIN. FENCE SETBACK UTIL. ESMT 9' UTIL. ESMT 50' ROADWAY WALK 4.5' PKWY 6.5' 6' BIKE 8' LN. PARK 6' BIKE LN. 8' PARK ROLL-OVER CURB Travel Walk 6' Pkwy 9.5' Bike Lane 115' ROW 12' 11' Travel 19' Median 15' Esmt. Util. Center 6' 3.5' Buffer Travel Walk 6' Pkwy 9.5' Bike Lane 12' 11' Travel 15' Esmt. Util. 3.5' 6' Buffer Sidewalk Sidewalk 84' - Travel Walk 6' Pkwy (min.) 9.5' Bike Lane 115' ROW 11' 12' Travel 7' Median 15' Esmt. Util. Center 6' 3.5' Buffer Travel Walk 6' Pkwy (min.) 9.5' Bike Lane 12' 11' Travel 15' Esmt. Util. 3.5' 6' Buffer Sidewalk Sidewalk 84' - Travel 12' FOUR-LANE ARTERIAL STREET (SUNIGA ROAD) FOUR-LANE ARTERIAL STREET INTERSECTION (SUNIGA ROAD) PRIVATE BOLAVARD (STREET D (STA 10+00-20+00) & STREET G) RESIDENTIAL LOCAL STREET (STREET A) INTERSECTIONS (WHERE NEEDED) INTERSECTIONS (WHERE NEEDED) INTERSECTIONS (WHERE NEEDED) INTERSECTIONS (WHERE NEEDED) INTERSECTIONS (WHERE NEEDED) RESIDENTIAL LOCAL STREET (STREET F) MINOR COLLECTOR STREET (STREET E (STA 31+00-34+00)) VARIANCE WILL BE SUPPLIED FOR THIS SECTION CONNECTOR LOCAL STREET (STREET B, STREET C, STREET H, STREET E (STA 10+00-29+50) RESIDENTIAL LOCAL STREET (STREET D (STA 20+00-23+00) 7.5' 20' ROW Back of Conc. 8' Util. Esmt. 8' Util. Esmt. 3' (min.) Fence Setback Concrete Pavements 16' ROW Back of Conc. 8' Util. Esmt. 8' Util. Esmt. 3' (min.) Fence Setback Concrete Pavements 20' ALLEY OPTION (A) (ALLEY 1, ALLEY 2, ALLEY 3, ALLEY 4, ALLEY 8, ALLEY 10, ALLEY 11, ALLEY 15, ALLEY 16, ALLEY 21, ALLEY 22, ALLEY 23, ALLEY 24, & ALLEY 25) 16' ALLEY OPTION (A) (ALLEY 5, ALLEY 6, ALLEY 7, ALLEY 9, ALLEY 12, ALLEY 13, ALLEY 15, ALLEY 17, ALLEY 18, ALLEY 19, & ALLEY 20) Walk 6' Pkwy 10' 15' Esmt. Util. 4:1 MAX 4:1 MAX Future Travel Lane 8' BIKE LN. 12' TRAVEL 12' TRAVEL 12' TRAVEL 50' -℄ 17' -℄ EXISTING GROUND EXISTING ASPHALT 30" VERTICAL CURB & GUTTER 4-LANE ARTERIAL (INTERIM TIMBERLINE ROAD) Walk 6' PKWY. 115' ROW 12' Travel 15' Esmt. Util. 10' Sidewalk 83' - FOUR-LANE ARTERIAL STREET (TIMBERLINE ROAD) 12' Travel 8' Bike Ln. 32' -℄ 19' Median 32' -℄ Walk 6' PKWY. 12' Travel 15' Esmt. Util. 10' Sidewalk 12' Travel 8' Bike Ln. 4:1 MAX 4:1 MAX 4:1 MAX 4:1 MAX 30" VERTICAL CURB & GUTTER 30" VERTICAL CURB & GUTTER 18" OUTFALL VERTICAL CURB & GUTTER 12' SHOULDER 80' - CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT EAST LARIMER COUNTY WATER DISTRICT UTILITY PLAN REVIEW E. BOXELDER GENERAL NOTES 1. Existing Utility Locates: It shall be the responsibility of the Contractor to coordinate field locates of all existing utilities prior to commencement of any construction. Contractor shall also notify all affected utility companies prior to commencing construction. In the event of damage to any existing utility, the contractor shall immediately notify the owner of the utility involved and unless authorized in writing by the owner of the subject utility, shall not attempt to make repairs. The cost of repairs shall be the responsibility of the Contractor. 2. District Owned Easement Pictures: Contractor to provide sequential digital pictures spaced at no more than 300 feet detailing conditions of the off-site Boxelder Owned Easement Conditions and any structures that could be affected, to the District and the property owner prior to the start of any off-site work. These pictures shall include all existing fence, ditches, ditch structures, out buildings, water troughs, trees and all other landscaping. Pictures are to be placed at no more than four (4) pictures on a 11x8 sheet of photo paper inserted into transparent sleeves and delivered with the drawings of record in a three (3) ring binder. 3. Protection of Property: Contractor shall continuously maintain adequate protection from damage of all public and private property through which the work is done. 4. Safety: All sewer main installation within the District shall be subject to current (Occupational Safety and Heath Association (OSHA) and the Colorado Safety Association, (CSA) safety requirements. Contractor shall also comply with any and all requirements and regulations as set forth by City, County, State and Federal agencies having applicable authority. 5. Start of Construction: No construction shall begin without prior design review of the District. The District shall be notified 48 hours in advance of starting construction or testing to allow for scheduling. 6. Road Excavation Permits: In event that State, County or City road excavation permit(s) are required, the Contractor is responsible for obtaining all road permits which may be required. 7. Other Permits: The Contractor shall be responsible for obtaining all permits required for construction. 8. Revisions: No verbal authorization for field revision shall be given. All requests for field revision shall be made in writing accompanied by proposed change indicated on copy of the approved design drawings. Any field revision approved and installed shall also be accurately documented on the Drawings of Record. 9. Materials: Plastic Pipe -All gravity sanitary sewer piping shall be Polyvinyl Chloride (PVC) unless otherwise noted on the approved drawings. Pipe 15” and smaller shall conform to ASTM D3034, Type PSM, and SDR 35. Pipe 18” and larger shall conform to ASTM F679. All fittings shall be (PVC) unless otherwise noted. 10. Pipe Cover: A minimum cover of 3-1/2 feet of cover shall be maintained throughout the sewer line and service line installation. 11. Bedding: All sewer main installation shall include bedding. Bedding shall be ¾” washed rock uniformly graded and compacted. Refer to force main desgin for force main bedding requirements. Trench shall be excavated to a depth below established grade equal to ¼ of pipe diameter (min. 4”). Bell depressions shall be provided for all joints. In event that unstable trench conditions are encountered at pipeline grade 1-1/2” uniformly graded washed rock shall be used for stabilization. Bedding material shall be placed and compacted under and around sides of the pipe. Place bedding in such a manner as to provide solid, uniform bearing surface for full length of barrel. Minimum 30” initial lift above pipe before other than hand compaction equipment is to be used. Note maximum trench width detail. 12. Backfill: Backfilling of trench shall be performed as soon as practical, subsequent to inspection and approval. Backfilling of acceptable material shall not be placed in lifts of greater than one (1) foot. Backfill shall be compacted to 95% of optimum density in roadway and residential areas and 90% in all off-site easement areas unless otherwise noted. Compaction testing of bedding and back fill shall be at least five tests per 1,000 feet and at varying depths and locations in accordance with the requirements of the applicable authority or as required in project specific specifications. 13. Concrete: All concrete construction shall be completed utilizing 3,000 psi at twenty-eight (28) days or equal concrete. 14. Pavement or Other Repairs: In event that asphalt or concrete pavement, sidewalks, storm sewers, waterline or any other public or privately owned property is damaged or requires reconstruction due to the work, repairs or replacement will be made in accordance with the requirements of the appropriate governing authority. Private property will be returned to its original condition or as close to original condition as reasonably possible, unless otherwise noted on the drawings. 15. Service Taps on Existing Lines: All taps made on existing lines shall be completed at developer's expense by District personnel or the District's authorized contractor with no exception. 16. Inspection: Construction shall conform to District Standards and Specifications or project specific specifications at all times. The District shall inspect the construction as necessary and shall observe all line testing. The District shall have the authority to ascertain that all construction of facilities is equal to or better than minimum construction requirements as set forth in 17. Testing: All lines shall be pressure tested and flushed by the Contractor in accordance with District Standards and Specifications and under the District's supervision. Upon passing, copies of all passing test results including soils compaction in the area of sewer main construction shall be provided to the District. 18. Acceptance: Upon completion of all utility construction (sewer and other) and fulfillment of all District requirements, preliminary acceptance of new sewer system improvements will occur in accordance with District's acceptance procedure. 19. Warranty: The Contractor shall warrant the materials, installation, workmanship and surface restoration for a period of two years from date of preliminary acceptance. During this warranty period the Developer shall promptly repair any defects in the work and maintain the work area. At the close of the two-year warranty period the District will make a field inspection. Upon satisfactory correction of any deficiencies noted the District would make final acceptance of the lines and work. The lines and the appurtenances shall then become the sole property and responsibility of Boxelder Sanitation District. 20. Drawings of Record and Total Costs: Within 90 days of preliminary acceptance of the new facilities, the District shall be provided with acceptable Drawings of Record of the complete system consisting of two sets of fill size reproduced prints, two sets of ½-size reproduced prints, one set of 6 mil double matted reproducible mylars and one complete digital file equivalent (software and version to be confirmed at time of delivery). Written confirmation of the total cost of all sewer system improvements shall also be submitted with the Drawings of Record. Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 03 of 54 C0.02 CONSTRUCTION NOTES GENERAL & E. EAST LARIMER COUNTY WATER DISTRICT GENERAL NOTES FOR CONSTRUCTION Version: 10/10/2017 The following information is condensed from the current "Standard Construction Specifications for Water Mains" (Specification) as adopted by the East Larimer County Water District (‘ELCO’ or ‘District’) and is to be considered as such. In the event of any conflict the full District Specification document shall take precedence over these general notes. 1. Standards and Specifications: Construction shall be per the District Specifications in effect at the start of construction. Material or equipment shall be manufactured per the most recent version of applicable industry standards 2. Locates: Contractor shall coordinate field locates of all existing utilities prior to commencement of any construction and as required notify all affected utility companies prior to commencing construction. Cost of repairs to any other utility damaged during District waterline installation shall be the responsibility of the Contractor. 3. Damage to Property: Contractor shall continuously maintain adequate protection from damage of all public and private property through which the work is done and shall be fully responsible for all costs associated with damage to any and all other public and private property. 4. Safety: Contractor shall comply with any and all requirements and regulations as set forth by City, County, State and Federal agencies having applicable authority. 5. Landscaping Adjacent to District Waterlines: No landscaping (bushes, shrubs, trees or other plantings) that has a mature height of over 3 feet (3-ft) shall be placed within ten feet (10-ft) of any District waterline or appurtenance (distribution main, service line, fire hydrant, meter, etc.). Bushes or shrubs with a mature height of less than 3-ft shall be placed a minimum 4-ft from any District waterline or appurtenance. The District shall have the right to remove any landscaping that violates this standard, at any time such landscaping is discovered, and shall not be required to replace the removed landscaping. 6. Design Approval and Construction Start: No construction shall begin without prior design approval from ELCO. District shall be notified 48 hours in advance of starting construction or testing to allow for scheduling. 7. Permits: Contractor is responsible for obtaining all County road permits which may be required. For any permitting where the District must apply for a permit the Contractor shall coordinate, cover the cost and schedule the permit acquisition with the District. 8. Changes During Construction: No verbal authorization for field revision shall be given. All requests for such field revision shall be made in writing accompanied by proposed change indicated on copy of the approved design drawings. Any field revision approved and installed shall also be accurately documented on the Contrctor’s As-Built drawings. 9. Materials of Construction: a. Pipe: All water piping shall be Polyvinyl Chloride (PVC). All PVC piping 6-inch through 12-inch shall be DR 18 (pressure class 235 psi) and manufactured in accordance with AWWA Standard C900, "Polyvinyl Chloride (PVC) Pressure Pipe, 4-inch through 12-inch, For Water Distribution". All PVC piping 14-inch through 24-inch shall be DR 18 (pressure class 235 psi) and manufactured in accordance with AWWA Standard C905, "Polyvinyl Chloride (PVC) Water Transmission Pipe, Nominal Diameters 14-inch through 36". Pipe with a diameter greater than 24 inches shall be specified based on engineered design. b. Tracer Wire: All water piping shall be installed with a twelve (12) gauge solid copper wire, plastic coated, six hundred (600) volt taped to top of pipe and surfaced at each valve as a tracer wire. c. Pipe Joints: Pipe joints shall be made using an integral bell with an elastomeric gasket push-on type joint or using machined couplings of a sleeve type with rubber ring gaskets and machined pipe ends to form a push-on type joint. d. Materials and Installation: All materials installed shall be free of manufacturer defects. Any defective or damaged materials noted on the construction site shall be so marked and removed from the site. Under no circumstances shall any PVC piping be installed utilizing mechanical equipment to seat the joints. e. Pipe Fittings: All fittings shall be mechanical joint, ductile iron, manufactured in accordance with AWWA Standard C153. Fittings shall be furnished with a cement-mortar lining of standard thickness class with a 250 psi pressure rating. f. Gate Valves: Gate valves shall conform to AWWA Standard C509 with mechanical joint, 2" open left operating nut and resilient seat. g. Butterfly Valves: Butterfly valves shall be used for all valves 12-inches and larger and conform to AWWA Standard C504 with mechanical joint, 2" open left operating nut, resilient seat and shall be equipped with sand bonnet. h. Fire Hydrants: Hydrants shall conform to AWWA Standard C502, 1" square open-right operating nut. Allowable manufacturers and models are Mueller Super Centurion with epoxy coated shoe or American Flo Control Waterous Pacer WB-67-250X with epoxy coated shoe. All fittings shall be swing assemblies with anchor couplings. i. Pipe, Valve and Fitting Wrap: All fittings, valves, fire hydrant shoes and plugs shall be poly-wrapped with 8-mil thick polyethylene plastic wrap, double layered, and ends securely taped prior to backfill. 10. Bedding: All pipe shall be bedded in 3/4" washed rock uniformly graded and compacted. Trench shall be excavated to a depth below established grade equal to 1 4 of pipe diameter (min. 4"). Bell depressions shall be provided for all joints. In event that unstable trench conditions are encountered at pipeline grade 1-1/2" uniformly graded washed rock shall be used for stabilization. Bedding material shall be placed and compacted under and around sides of the pipe. Minimum 30" backfill above pipe before other than hand compaction equipment is to be used. Note maximum trench width detail. 11. Backfill: Backfill of acceptable material shall be placed in lifts not greater than one (1) foot. Backfill shall be compacted to 95% of optimum density in roadway areas or per road authority’s requirements, and 90% in all other locations. Compaction testing of bedding and backfill shall be at least five tests per 1,000 feet and at varying depths and locations in accordance with the requirements of the applicable authority. 12. Joint Restraint: All fittings, tees, plugs and fire hydrants shall be provided with anchor couplings and/or joint restraint in accordance with District Specifications or as required per engineer’s design. Thrust blocks shall be used only as required per field conditions and as approved or directed by the District field inspector. 13. Concrete: All concrete construction, including thrust blocks, shall be completed utilizing Type 5 or equal cement only. 14. Asphalt Replacement: For asphalt pavement that is cut and has been in place less than two years (according to City or County Engineer's record), the cut shall be a minimum of 20 feet in width and will be replaced to the specified depth by a paving machine. 15. Pipe Cover: A minimum cover of 4-1/2 feet of cover over top of pipe shall be maintained throughout the waterline and service line installation, particularly in areas of new grading and drainage swales. Extra bury depth may be required to maintain minimum cover at drainage culvert crossings and/or fire hydrant runs. Maximum allowable cover shall be 6 feet, unless specifically approved by the District. 16. Connection to Existing System: All connections to existing waterlines shall be completed at developer's expense by District personnel or the District's authorized contractor with no exception. 17. Inspection: The District shall have the authority to inspect and verify that all construction of facilities is equal to or better than minimum construction requirements as set forth in the District’s Specifications. The District shall also have the authority to assign an inspector to check any and all work, including all materials to be incorporated in the work, excavation, bedding, backfill, testing and all construction methods and practices. 18. Testing and Acceptance: All lines shall be pressure tested, chlorinated and flushed by the Contractor in accordance with District Specifications and under the District's supervision. Upon passing chlorination testing, bacteriological testing will be completed by a State certified water quality control laboratory. Copies of all passing test results, including soils compaction in the area of water main construction, shall be provided to the District. 19. Project As-Built and Record Drawing Requirements: a. As-built drawings are prepared by the contractor. They confirm, in red ink, on-site changes to the original construction documents. The As-built drawings shall be delivered to the project’s design engineer for conversion to Record Drawings. A PDF version shall be delivered to the District. b. Record Drawings are prepared by the project’s design engineer and reflect on-site changes the contractor noted in the As-built drawings. The Record Drawings shall be approved by the District prior to Preliminary Acceptance of the project. Record Drawings are to be delivered to the District in hard copy (11 x 17 format) and electronic format. Hard copy drawing text font size shall be large enough to be legible with font size approved by the District. Electronic format shall be delivered in Adobe (PDF), AutoCAD and ArcView shape files (release version to be confirmed with District at time of submittal). These documents shall accurately reflect any change made in the field which varies from the approved construction plan and including, at a minimum, field dimensions and elevations, horizontal and vertical locations of underground utilities and appurtenances. Include with the Record Drawings a complete copy of the recorded Filing Plat and a written confirmation of total costs of all water system improvements involved. 20. Warranty: The Contractor shall warrant all work associated with the waterline installation including, but not limited to the materials, installation workmanship and surface restoration for a period of two years from date of Preliminary Acceptance. During this warranty period the Contractor shall repair any defects in the work and maintain the work area. At the close of the two-year warranty period and upon satisfactory correction of any deficiencies noted, the District shall accept the constructed lines and appurtenances as the sole property and responsibility of the District. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer's absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The the City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by Larimer County. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: BENCHMARK #92-1 - LOCATED ALONG EAST VINE DR. AT THE PLEASANT VALLEY AND LAKE CANAL, ON A BRIDGE ON THE TOP OF THE NORTHWEST HEADWALL. ELEVATION: 4946.31 BENCHMARK #2-07 - LOCATED ON VINE DRIVE, 0.1 MILE WEST OF TIMBERLINE RD., 50FT NORTH OF THE ENTRANCE TO BULL RUN TOWNHOMES ON THE NORTHWEST CORNER OF THE WEST CATCHBASIN. ELEVATION: 4959.98 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.18' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHWEST QUARTER OF SECTION 5 AS BEARING SOUTH 88°53'23" EAST (ASSUMED BEARING). 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: · N/A CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. See separate Stormwater Management Plan / Erosion Control Report for Waterfield Third Filing for additional information. 17. A vehicle tracking control pad shall be installed when needed for construction equipment, including but not limited to personal vehicles exiting existing roadways. No earthen materials, i.e. stone, dirt, etc. shall be placed in the curb & gutter or roadway as a ramp to access temporary stockpiles, staging areas, construction materials, concrete washout areas, and/or building sites. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Final Drainage and Erosion Control Report for Waterfield Third Filing dated April 9th, 2014 by Northern Engineering Services, Inc., shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT EAST LARIMER COUNTY WATER DISTRICT UTILITY PLAN REVIEW Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com 02 of 54 C0.01 CONSTRUCTION NOTES GENERAL & C1.02-C1.07 DEMOLITION PLAN Northern Engineering Services, Inc NE Project No. 889-003 Date: June 13, 2013 ADDITIONAL FIELD SURVEYS: Northern Engineering Services, Inc Date(s): July 27, 2013 ORIGINAL FIELD SURVEY BY: A.G. Wassenaar Inc. "Geotechnical Site Development Study Waterfield Development Northwest of East Vine Drive and North Timberline Road" Project No. 131041 Date: June 12, 2013 SUBSURFACE EXPLORATION BY: DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. A. G. Wassenaar, Inc. Kathleen A. Noonan, PE 2180 South Ivanhoe Street, Suite 5 Denver, Colorado 880222-5710 (303) 759-8100 GEOTECHNICAL ENGINEER Thrive Home Builders 1875 Lawrence St., Suit 900 Denver, CO 80202 (303) 707-4400 OWNER Sheet THRIVE These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET E NGINEER ING N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 54 C0.00 COVER SHEET 01 UTILITY PLAN APPROVAL BOXELDER SANITATION DISTRICT EAST LARIMER COUNTY WATER DISTRICT UTILITY PLAN REVIEW GRADING SHEETS C3.00 OVERALL GRADING PLAN C3.01-C3.06 GRADING PLANS ROAD SHEETS C4.00 STREET A PLAN & PROFILE C4.01-C4.03 STREET B PLAN & PROFILE C4.04-C4.05 STREET C PLAN & PROFILE C4.06-C4.07 STREET D PLAN & PROFILE C4.08-C4.10 STREET E PLAN & PROFILE C4.11 STREET F PLAN & PROFILE C4.12 STREET G PLAN & PROFILE C4.21-C4.22 TIMBERLINE ROAD INTERIM PLAN & PROFILE C4.23-C4.27 TIMBERLINE ROAD ULTIMATE PLAN & PROFILE DRAINAGE SHEETS C5.00 DRAINAGE PLAN ENGINEER ING N O R T H E RN PROJECT BENCHMARKS: PROJECT DATUM: NAVD88 BENCHMARK #92-1 - LOCATED ALONG EAST VINE DR. AT THE PLEASANT VALLEY AND LAKE CANAL, ON A BRIDGE ON THE TOP OF THE NORTHWEST HEADWALL. ELEVATION: 4946.31 BENCHMARK #2-07 - LOCATED ON VINE DRIVE, 0.1 MILE WEST OF TIMBERLINE RD., 50FT NORTH OF THE ENTRANCE TO BULL RUN TOWNHOMES ON THE NORTHWEST CORNER OF THE WEST CATCHBASIN. ELEVATION: 4959.98 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED (PRIOR CITY OF FORT COLLINS DATUM) FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM (PRIOR CITY OF FORT COLLINS DATUM) IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED (PRIOR CITY OF FORT COLLINS DATUM) = NAVD88 - 3.18' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE SOUTH LINE OF THE SOUTHWEST QUARTER OF SECTION 5 AS BEARING SOUTH 88°53'23" EAST (ASSUMED BEARING). C4.13-C4.14 STREET H PLAN & PROFILE C4.15-C4.20 SUNIGA ROAD PLAN & PROFILE