HomeMy WebLinkAboutELITE INFUSED (5724 S. COLLEGE AVE.) - BASIC DEVELOPMENT REVIEW - BDR180013 - SUBMITTAL DOCUMENTS - ROUND 2 - SITE PLANHC
AC
TR
AC
TR
TR
TR
B
B
B
B
B
20' POWER &
PHONE
UTILITY
EASEMENT
(PLAT)
5.8'
9.7'
13.3'
18.4'
EM
EM
EM
GM
10.2'
9.2'
10.0'
21.7'
GM
GM
SHRUBS
G
G
G
R
G
G
G
G G
G
G
G
G
G
R R
R
R
R
R
17.07
20.84
20.26
NEW LOADING BAY
VEHICLE DOOR
NEW VEHICLE DOOR
25.68
23' typ.
6.00
NEW FIRE HYDRANT
REV
125 South Howes
10th Floor Suite 1000
Fort Collins, CO 80521
office (970) 672-8394 fax (970) 407-9244
ELITE INFUSED CULTIVATION FACILITY
5724 SOUTH COLLEGE AVENUE DRAWN BY:
CHECKED BY:
PROJECT NO.:
DATE:
DESCRIPTION BY DATE
FT COLLINS, CO
SITE PLAN NOTES AND
DETAILS
2
SEPTEMBER 9, 2018
60-001
FCE
DLF
2
WALL CAP BOARD
(1"x9.25")- FIBER CEMENT BOARD
SMOOTH PAINTED
SLOPED OVER
1
4" BLOCKING
HORIZONTAL LAP SIDING -
(FIBER CEMENT)(5" EXPOSURE)
(SMOOTH PAINTED SURFACE ALL FACES)
OVER (TYVEK) WEATHER BARRIER
ATTACHED TO WALL PER MANUFACTURER
SPECIFICATIONS.
SEAL ALL
SIDING/TRIM
CONNECTIONS WITH
20-YEAR SEALANT
CONCRETE FOUNDATION
10" TYP. WIDTH
CONCRETE SLAB (6" THK.)
SLOPES
1
4" BACK TO FRONT
6" WOOD FRAMED WALL
· TREATED 2X6 @ 16" O.C.
· OSB SHEATHING BOTH FACES
6" WOOD FRAMED WALL
DOUBLE TOP PLATE
2-2X6 TREATED WOOD
WALL CAP BOARD
FIBER CEMENT BOARD SMOOTH - PAINTED TRIM COLOR
TRIM BOARD
FIBER CEMENT BOARD 1"x6"
RUFF SURFACE - PAINTED TRIM COLOR
HORIZONTAL LAP SIDING -
FIBER CEMENT LAP SIDING SMOOTH - PAINTED BODY COLOR
GATE BOLLARDS
(6"x6"x
5
8"thk.)- STEEL TUBING
WITH GATE HINGES, & CONCRETE FILLED
PAINTED TRIM COLOR
TYPICAL OF 2
STEEL GATE FRAME
PERIMITER FRAME - STEEL TUBING (3"x3"x 1/4"thk.)
HANG FROM GATE BOLLARD BY 3 - HINGES
ADDITIONAL DETAILS AND STRUCTURE BY FABRICATOR
PAINTED TRIM COLOR
TYPICAL OF 2
EMBED GATE BOLLARDS
40" BELOW GRADE
TYPICAL OF 2
CANE BOLTS WITH
STEEL SLEEVE
EMBEDS
STEEL GATE FRAME
TYPICAL OF 2
GATER BOLLARD
TYPICAL OF 2
RECYCLE
CONTAINER
CONCRETE OR ASPHALT SURFACE
SLOPED AWAY FROM ENCLOSURE OPENING
STEEL GATE DECKING
1-1/2" STEEL DECKING
WELD TO STEEL GATE FRAME
PAINTED BODY COLOR
TYPICAL OF 2
*STEEL TUBING IS ASTM A500 GRADE -B
PAINT - COLOR
BODY COLOR - MATCH EXISTING BUILDING BODY COLOR
TRIM COLOR - MATCH EXISTING BUILDING TRIM COLOR
RECYCLE
CONTAINER
12'-0"
9'-0"
12'-0"
WOOD FRAMED
ACCESS DOOR
36" OPENING
N.T.S.
9'-0"
6'-0"
5'-2"
6'-0"
PLAN VIEW
FRONT ELEVATION
TYPICAL SIDE ELEVATION
TRASH ENCLOSURE DETAILS
N.T.S.
TRASH ENCLOSURE
WALL SECTION
N.T.S.
STD. DRAWING 1702
CONST. DWG. 1701
CONST. DWG. 1701
SITE PLAN NOTES:
1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE
PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES
TO THE PLANS.
2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM
DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS.
3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF
ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION.
4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM
ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH
SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF
THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND
PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES.
5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A
PHASING PLAN IS SHOWN WITH THESE PLANS.
6. NOT APPLICABLE
7. NOT APPLICABLE
8. NOT APPLICABLE
9. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION
3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP
CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION.
10. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE
APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN
CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY.
11. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS.
12. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED.
13. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE
PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING
SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL
ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN
1:48 CROSS SLOPE.
14. NOT APPLICABLE
15.NOT APPLICABLE
16.NOT APPLICABLE
17.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS
STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION
OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE
DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE
ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY.
18. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE
OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE
CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING
FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR
PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE
MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN
NECESSARY TO PROVIDE ADEQUATE VISIBILITY.
19. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY
THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY.
UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING.
ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING
IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD
FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING
BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED
FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE
STRUCTURE.
FIRE
LANE
NO
PARKING
STANDARD
FIRE LANE SIGN DETAIL
UNIVERSAL
FIRE LANE SIGN DETAIL
(FORT COLLINS ONLY)
RE: UTILITY PLAN FCLWD
EXIST. WATER
SERVICE LINE
NO ADJOINING
SIDEWALKS
WITHIN
1
2
MILE
8.00 typ.
28.01
18.42
5
MAIN ENTRY
OFFICE ENTRY
BIKE PARKING 3x ARRAY
RE: BIKE RACK DETAIL
LCUASS 1701
EXIST. ASPHALT
EXIST. ASPHALT
EXIST.
ASPHALT
EXISTING PUBLIC
PARKING
WITHIN ROW
NOT A PART of
SITE
6" VERTICAL CURB & GUTTER
U.S. HIGHWAY 287
FRONTAGE ROAD
(SOUTH COLLEGE AVENUE)
(R.O.W. VARIES)
0.9'
EXIST. CURB, GUTTER, &
ASPHALT DRIVEWAY
ARE SOUTH OF
PROPERTY LINE 2.8'
METAL
SHED
ON
DOCK
EXIST.
ADJACENT BUILDING
EXIST.
1 STORY
BRICK HOUSE
#5724
1462 sf
30.8'
40.5'
15.4'
14.0'
15.4'
54.5'
40.2'
70.2'
70.2'
40.2'
EXIST. CONC. WALL
EXIST.
COVERED
PATIO
215 sf
ELECTRIC
BOX
EXIST. BLOCK WALL
EXIST. BLOCK WALL
EXIST. FENCE IS NORTH
OF PROPERTY LINE
FENCE IS NORTH
OF PROPERTY LINE
6' UTILITY EASEMENT (PLAT)
EXIST.
CONC.
WALL
EXIST. CURB
WALL BEGINS
EXIST.
CONCRETE PAN
EXIST.
METAL
WAREHOUSE
REMODEL
3,460 sf
EXIST.
ELEVATED
LOADING
DOCK
NO ADJOINING
SIDEWALKS
WITHIN
1
2
MILE
EXIST.
6" CURB & GUTTER
EXIST. CONCRETE
PARKING PAD
2 VEHICLE
SPACES
EXIST. ASPHALT
S89°15'15"E
N00°43'35"E
90.11'
90.00' (R)
S00°26'20"W
90.00'
S89°17'15"E
195.18'
(195.15' R)
NOT A PART
LOT 27 (20528 S.F.)
NOT A PART
LOT 29 (18449 S.F.)
20' FIRE ACC.
ESMT.
NOT A PART
LOT 39 (11450 S.F.)
NOT A PART
LOT 38 (11450 S.F.)
NOT A PART
LOT 40 (11450 S.F.)
NEW FIRE
ACCESS
EASEMENT
NEW FIRE
ACCESS
EASEMENT
VEHICLE
ACCESS
AISLE
NEW TRASH
ENCLOSURE
RE: SITE DETAILS
EXIST.
ASPHALT
EXIST.
ACCESIBLE PED
RAMP
IRRIGATION
EASEMENT (PLAT)
EXISTING COMMERCIAL METER
TO REMAIN
194.73' (194.53' R)
TRASH
REC.
REC.
25'
WATER & SEWER
UTILITY EASEMENT
S COLLEGE AVE
E SKYWAY DR
E HARMONY RD
FOSSIL
CREEK
PKWY
S BOARDWALK DR
S LEMAY AVE
S SHIELDS ST
E TRIBLY RD
SITE
REV
125 South Howes
10th Floor Suite 1000
Fort Collins, CO 80521
office (970) 672-8394 fax (970) 407-9244
ELITE INFUSED CULTIVATION FACILITY
5724 SOUTH COLLEGE AVENUE DRAWN BY:
CHECKED BY:
PROJECT NO.:
DATE:
DESCRIPTION BY DATE
FT COLLINS, CO
SITE PLAN
2
SEPTEMBER 9, 2018
60-001
FCE
DLF
1
BASIC DEVELOPMENT REVIEW
ELITE INFUSED - RETAIL MARIJUANA CULTIVATION FACILITY
SOUTH 13 SUBDIVISION THIRD FILING
5724 SOUTH COLLEGE AVENUE - FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
Feet
0 20 40
SITE PLAN
SCALE, 1" = 10'-0"
LEGAL DESCRIPTION:
SOUTH 13 SUBDIVISION THIRD FILING,
CITY OF FORT COLLINS, COUNTY OF LARIMER,
STATE OF COLORADO
NOT A PART
LOT 27, LOT 29, LOT 38, LOT 39 & LOT 40 & RIGHT
OF WAY OF SOUTH 13 SUBDIVISION.
STREET ADDRESS:
5724 SOUTH COLLEGE AVENUE
FORT COLLINS, CO
OWNER INFORMATION:
LAND USE DATA TABLE -
TOTAL (SF) %
BUILDING FOOTPRINTS
1 - STORY BRICK (1,678 SF)
METAL WAREHOUSE (3,185 SF) 4,863 27.7%
PAVED AREAS
(DRIVES, PARKING, & WALKS) 6,784 38.6%
LANDSCAPING
MULCK ROCK (2,312 SF)
GRASS (3,597 SF) 5,910 33.7%
TOTAL 17,557 100.0%
IMPERVIOUS AREA
EXISTING 11,688 66.6%
NEW 11,688 66.6%
SITE INFORMATION:
PARCEL NUMBER
ZONING: COMMERCIAL SERVICE
ADJACENT ZONING
NORTH: COMMERCIAL SERVICE
EAST: COMMERCIAL SERVICE
SOUTH: COMMERCIAL SERVICE
WEST OF HIGHWAY: COMMERCIAL GENERAL
TOTAL SITE AREA - 17,557 SF OR (0.40 ACRES)
TOTAL BUILDING AREA
1 - STORY BRICK (1,670 SF) FAR (.10)
METAL WAREHOUSE (3,460 SF) FAR (.20)
OCCUPANCY
1 - STORY BRICK: R (RESIDENTIAL)
METAL WAREHOUSE
B (OFFICES)
M (MARIJUANA CULTIVATION)
PRELIMINARY
NOT FOR
CONSTRUCTION