Loading...
HomeMy WebLinkAboutELITE INFUSED (5724 S. COLLEGE AVE.) - BASIC DEVELOPMENT REVIEW - BDR180013 - SUBMITTAL DOCUMENTS - ROUND 2 - SITE PLANHC AC TR AC TR TR TR B B B B B 20' POWER & PHONE UTILITY EASEMENT (PLAT) 5.8' 9.7' 13.3' 18.4' EM EM EM GM 10.2' 9.2' 10.0' 21.7' GM GM SHRUBS G G G R G G G G G G G G G G R R R R R R 17.07 20.84 20.26 NEW LOADING BAY VEHICLE DOOR NEW VEHICLE DOOR 25.68 23' typ. 6.00 NEW FIRE HYDRANT REV 125 South Howes 10th Floor Suite 1000 Fort Collins, CO 80521 office (970) 672-8394 fax (970) 407-9244 ELITE INFUSED CULTIVATION FACILITY 5724 SOUTH COLLEGE AVENUE DRAWN BY: CHECKED BY: PROJECT NO.: DATE: DESCRIPTION BY DATE FT COLLINS, CO SITE PLAN NOTES AND DETAILS 2 SEPTEMBER 9, 2018 60-001 FCE DLF 2 WALL CAP BOARD (1"x9.25")- FIBER CEMENT BOARD SMOOTH PAINTED SLOPED OVER 1 4" BLOCKING HORIZONTAL LAP SIDING - (FIBER CEMENT)(5" EXPOSURE) (SMOOTH PAINTED SURFACE ALL FACES) OVER (TYVEK) WEATHER BARRIER ATTACHED TO WALL PER MANUFACTURER SPECIFICATIONS. SEAL ALL SIDING/TRIM CONNECTIONS WITH 20-YEAR SEALANT CONCRETE FOUNDATION 10" TYP. WIDTH CONCRETE SLAB (6" THK.) SLOPES 1 4" BACK TO FRONT 6" WOOD FRAMED WALL · TREATED 2X6 @ 16" O.C. · OSB SHEATHING BOTH FACES 6" WOOD FRAMED WALL DOUBLE TOP PLATE 2-2X6 TREATED WOOD WALL CAP BOARD FIBER CEMENT BOARD SMOOTH - PAINTED TRIM COLOR TRIM BOARD FIBER CEMENT BOARD 1"x6" RUFF SURFACE - PAINTED TRIM COLOR HORIZONTAL LAP SIDING - FIBER CEMENT LAP SIDING SMOOTH - PAINTED BODY COLOR GATE BOLLARDS (6"x6"x 5 8"thk.)- STEEL TUBING WITH GATE HINGES, & CONCRETE FILLED PAINTED TRIM COLOR TYPICAL OF 2 STEEL GATE FRAME PERIMITER FRAME - STEEL TUBING (3"x3"x 1/4"thk.) HANG FROM GATE BOLLARD BY 3 - HINGES ADDITIONAL DETAILS AND STRUCTURE BY FABRICATOR PAINTED TRIM COLOR TYPICAL OF 2 EMBED GATE BOLLARDS 40" BELOW GRADE TYPICAL OF 2 CANE BOLTS WITH STEEL SLEEVE EMBEDS STEEL GATE FRAME TYPICAL OF 2 GATER BOLLARD TYPICAL OF 2 RECYCLE CONTAINER CONCRETE OR ASPHALT SURFACE SLOPED AWAY FROM ENCLOSURE OPENING STEEL GATE DECKING 1-1/2" STEEL DECKING WELD TO STEEL GATE FRAME PAINTED BODY COLOR TYPICAL OF 2 *STEEL TUBING IS ASTM A500 GRADE -B PAINT - COLOR BODY COLOR - MATCH EXISTING BUILDING BODY COLOR TRIM COLOR - MATCH EXISTING BUILDING TRIM COLOR RECYCLE CONTAINER 12'-0" 9'-0" 12'-0" WOOD FRAMED ACCESS DOOR 36" OPENING N.T.S. 9'-0" 6'-0" 5'-2" 6'-0" PLAN VIEW FRONT ELEVATION TYPICAL SIDE ELEVATION TRASH ENCLOSURE DETAILS N.T.S. TRASH ENCLOSURE WALL SECTION N.T.S. STD. DRAWING 1702 CONST. DWG. 1701 CONST. DWG. 1701 SITE PLAN NOTES: 1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. NOT APPLICABLE 7. NOT APPLICABLE 8. NOT APPLICABLE 9. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 10. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 11. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. 12. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 13. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 14. NOT APPLICABLE 15.NOT APPLICABLE 16.NOT APPLICABLE 17.ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 18. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 19. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. FIRE LANE NO PARKING STANDARD FIRE LANE SIGN DETAIL UNIVERSAL FIRE LANE SIGN DETAIL (FORT COLLINS ONLY) RE: UTILITY PLAN FCLWD EXIST. WATER SERVICE LINE NO ADJOINING SIDEWALKS WITHIN 1 2 MILE 8.00 typ. 28.01 18.42 5 MAIN ENTRY OFFICE ENTRY BIKE PARKING 3x ARRAY RE: BIKE RACK DETAIL LCUASS 1701 EXIST. ASPHALT EXIST. ASPHALT EXIST. ASPHALT EXISTING PUBLIC PARKING WITHIN ROW NOT A PART of SITE 6" VERTICAL CURB & GUTTER U.S. HIGHWAY 287 FRONTAGE ROAD (SOUTH COLLEGE AVENUE) (R.O.W. VARIES) 0.9' EXIST. CURB, GUTTER, & ASPHALT DRIVEWAY ARE SOUTH OF PROPERTY LINE 2.8' METAL SHED ON DOCK EXIST. ADJACENT BUILDING EXIST. 1 STORY BRICK HOUSE #5724 1462 sf 30.8' 40.5' 15.4' 14.0' 15.4' 54.5' 40.2' 70.2' 70.2' 40.2' EXIST. CONC. WALL EXIST. COVERED PATIO 215 sf ELECTRIC BOX EXIST. BLOCK WALL EXIST. BLOCK WALL EXIST. FENCE IS NORTH OF PROPERTY LINE FENCE IS NORTH OF PROPERTY LINE 6' UTILITY EASEMENT (PLAT) EXIST. CONC. WALL EXIST. CURB WALL BEGINS EXIST. CONCRETE PAN EXIST. METAL WAREHOUSE REMODEL 3,460 sf EXIST. ELEVATED LOADING DOCK NO ADJOINING SIDEWALKS WITHIN 1 2 MILE EXIST. 6" CURB & GUTTER EXIST. CONCRETE PARKING PAD 2 VEHICLE SPACES EXIST. ASPHALT S89°15'15"E N00°43'35"E 90.11' 90.00' (R) S00°26'20"W 90.00' S89°17'15"E 195.18' (195.15' R) NOT A PART LOT 27 (20528 S.F.) NOT A PART LOT 29 (18449 S.F.) 20' FIRE ACC. ESMT. NOT A PART LOT 39 (11450 S.F.) NOT A PART LOT 38 (11450 S.F.) NOT A PART LOT 40 (11450 S.F.) NEW FIRE ACCESS EASEMENT NEW FIRE ACCESS EASEMENT VEHICLE ACCESS AISLE NEW TRASH ENCLOSURE RE: SITE DETAILS EXIST. ASPHALT EXIST. ACCESIBLE PED RAMP IRRIGATION EASEMENT (PLAT) EXISTING COMMERCIAL METER TO REMAIN 194.73' (194.53' R) TRASH REC. REC. 25' WATER & SEWER UTILITY EASEMENT S COLLEGE AVE E SKYWAY DR E HARMONY RD FOSSIL CREEK PKWY S BOARDWALK DR S LEMAY AVE S SHIELDS ST E TRIBLY RD SITE REV 125 South Howes 10th Floor Suite 1000 Fort Collins, CO 80521 office (970) 672-8394 fax (970) 407-9244 ELITE INFUSED CULTIVATION FACILITY 5724 SOUTH COLLEGE AVENUE DRAWN BY: CHECKED BY: PROJECT NO.: DATE: DESCRIPTION BY DATE FT COLLINS, CO SITE PLAN 2 SEPTEMBER 9, 2018 60-001 FCE DLF 1 BASIC DEVELOPMENT REVIEW ELITE INFUSED - RETAIL MARIJUANA CULTIVATION FACILITY SOUTH 13 SUBDIVISION THIRD FILING 5724 SOUTH COLLEGE AVENUE - FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO Feet 0 20 40 SITE PLAN SCALE, 1" = 10'-0" LEGAL DESCRIPTION: SOUTH 13 SUBDIVISION THIRD FILING, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO NOT A PART LOT 27, LOT 29, LOT 38, LOT 39 & LOT 40 & RIGHT OF WAY OF SOUTH 13 SUBDIVISION. STREET ADDRESS: 5724 SOUTH COLLEGE AVENUE FORT COLLINS, CO OWNER INFORMATION: LAND USE DATA TABLE - TOTAL (SF) % BUILDING FOOTPRINTS 1 - STORY BRICK (1,678 SF) METAL WAREHOUSE (3,185 SF) 4,863 27.7% PAVED AREAS (DRIVES, PARKING, & WALKS) 6,784 38.6% LANDSCAPING MULCK ROCK (2,312 SF) GRASS (3,597 SF) 5,910 33.7% TOTAL 17,557 100.0% IMPERVIOUS AREA EXISTING 11,688 66.6% NEW 11,688 66.6% SITE INFORMATION: PARCEL NUMBER ZONING: COMMERCIAL SERVICE ADJACENT ZONING NORTH: COMMERCIAL SERVICE EAST: COMMERCIAL SERVICE SOUTH: COMMERCIAL SERVICE WEST OF HIGHWAY: COMMERCIAL GENERAL TOTAL SITE AREA - 17,557 SF OR (0.40 ACRES) TOTAL BUILDING AREA 1 - STORY BRICK (1,670 SF) FAR (.10) METAL WAREHOUSE (3,460 SF) FAR (.20) OCCUPANCY 1 - STORY BRICK: R (RESIDENTIAL) METAL WAREHOUSE B (OFFICES) M (MARIJUANA CULTIVATION) PRELIMINARY NOT FOR CONSTRUCTION