HomeMy WebLinkAboutFTC OLD TOWN, WTE (VERIZON) - BASIC DEVELOPMENT REVIEW - BDR180018 - SUBMITTAL DOCUMENTS - ROUND 2 - PLANSFTC OLD TOWN LIBRARY
201 PETERSON ST
FORT COLLINS, COLORADO 80524
NEW ROOFTOP MACRO
ZONING DRAWINGS
PROJECT
AREA
SITE DIRECTIONS
FROM 3131 SOUTH VAUGHN WAY:
GET ON I-225 N FROM SOUTH URSULA ST, S.VAUGHN WAY AND E. ILIFF AVE. FROM I-225 N TAKE
E-470 N TO I-25 N. TAKE I-25 N TO CO-14 W/E MULBERRY ST IN LARIMER COUNTY. TAKE EXIT 269B
FROM I-25 N. FOLLOW E. MULBERRY ST TO PETERSON ST IN FORT COLLINS.
FORT COLLINS, COLORADO
CLIENT
PROPERTY OWNER
VERIZON WIRELESS REAL ESTATE
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JENNIFER SCHNEIDER
PHONE: 303-901-3092
POUDRE RIVER PUBLIC LIBRARY DISTRICT
CONTACT: MARK HUBER
PHONE: 970-221-6662
301 E. OLIVE ST
FORT COLLINS, CO 80524
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2015 (W/LOCAL AMENDMENTS)
NEC 2017
NFPA-1 (2006)
U - UTILITY
IIB
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 ENLARGED SITE PLAN
Z-3
PROJECT DESCRIPTION
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
GENERAL
NOTES
GN-1
2
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0097
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC OLD TOWN LIBRARY
SITE ADDRESS:
201 PETERSON ST
FORT COLLINS, CO 80524
JURISDICTION:
CITY OF FORT COLLINS
A 10-06-17 GAC 90% ZONING DRAWINGS
SHEET NUMBER:
B 05-02-18 JID 90% ZONING DRAWINGS
C 08-24-18 LCW REVISED ZONING DRAWINGS
GENERAL NOTES:
1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY
RLF CONSULTING, DATED 08/23/18.
2. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND
REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS
THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES.
4. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY
CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF
WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE
CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS
PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE
CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY.
6. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS,
EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE
INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
7. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT
THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF.
THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED.
9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS
REQUIRED).
11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE.
12. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE.
13. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE
RECEPTACLES.
14. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988).
15. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER.
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0097
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC OLD TOWN LIBRARY
SITE ADDRESS:
201 PETERSON ST
FORT COLLINS, CO 80524
JURISDICTION:
CITY OF FORT COLLINS
A 10-06-17 GAC 90% ZONING DRAWINGS
SHEET NUMBER:
B 05-02-18 JID 90% ZONING DRAWINGS
C 08-24-18 LCW REVISED ZONING DRAWINGS
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTHEAST)
SCALE: N.T.S.
PHOTOSIMULATIONS
PH-1
3
2
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTHEAST)
SCALE: N.T.S.
E
ET
VP
VP
VP
VP VP
VP
GAS GAS GAS GAS GAS GAS GAS GAS GAS
GAS
T T
SS SS SS SS
UE UE UE UE UE UE UE
UE UE
UE UE
UE UE UE UE UE
F F
F F F F
F F F F F
G
M
F F F F F F F F F
EM
E
ET
E
ET
VP
VP
VP
VP VP
VP
VP
GAS GAS GAS GAS GAS GAS GAS GAS GAS
GAS
T T
SS SS SS SS
UE UE UE UE UE UE UE
UE UE
UE UE
UE UE UE
UE UE
F F
F F F F
F F F F F
GM
F F F F F F F F F
F
EM
E
E
T
VP
VP
EE
F
EXISTING 66'-0"
VACATED RIGHT OF WAY
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
ET
VP
VP
VP VP
VP
GAS GAS GAS GAS GAS GAS GAS
UE UE UE UE UE UE
GM
EM
E
E E E E E E
ET
ET
VP
VP
VP VP
VP
VP
GAS GAS GAS GAS GAS GAS GAS
UE UE UE UE UE UE
GM
F F F F F
F
EM
E
E E E E E E
ET
VP
VP
E E E
E E E E E
E E E
E E E E E
F
F F F F F
F
18'-0"
18'-0"
6'-0"
2'-0"
7'-0"
23'-0"
2'-6"
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
N
1
Z-2
ENLARGED SITE PLAN
SCALE: 3/16"=1'-0"
3/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1 0 1 2 4 8 16
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
EXISTING
PENTHOUSE
LIBRARY
27'-0"
30'-0"
41'-0"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0097
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC OLD TOWN LIBRARY
SITE ADDRESS:
201 PETERSON ST
FORT COLLINS, CO 80524
JURISDICTION:
CITY OF FORT COLLINS
A 10-06-17 GAC 90% ZONING DRAWINGS
SHEET NUMBER:
B 05-02-18 JID 90% ZONING DRAWINGS
C 08-24-18 LCW REVISED ZONING DRAWINGS
TOP OF STRUCTURE
41'-0" AGL
TOP OF PARAPET
30'-0" AGL
TOP OF ROOF
27'-0" AGL
GRADE
0'-0" AGL
EXISTING SKYLIGHT
(TYP)
EXISTING HVAC UNIT
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
1
Z-3
EXISTING EAST ELEVATION
SCALE: 3/16"=1'-0"
3/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1 0 1 2 4 8 16
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
EXISTING
ELEVATION
Z-3
6
EXISTING PENTHOUSE
LIBRARY
27'-0"
30'-0"
41'-0"
48'-0"
52'-0"
55'-0"
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
1
Z-4
PROPOSED EAST ELEVATION
SCALE: 3/16"=1'-0"
3/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1 0 1 2 4 8 16
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
TOP OF ROOF
27'-0" AGL
PROPOSED
ELEVATION
Z-4
7
PROPOSED 16'-8"x 16'-8" VERIZON CONCEALMENT WALL
PROPOSED CAGED ACCESS LADDER FROM
LOWER ROOFTOP TO PENTHOUSE
EXISTING SKYLIGHT (TYP)
TOP OF PARAPET
30'-0" AGL
TOP OF STRUCTURE
41'-0" AGL
PROPOSED VERIZON RAD CENTER
48'-0" AGL
TOP OF PROPOSED VERIZON ANTENNA
52'-0" AGL
TOP OF PROPOSED CONCEALMENT SHROUD
55'-0" AGL
PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM
TRI-SECTOR MOUNT BEHIND SCREEN WALL
(TYP OF 4 PER SECTOR, 16 TOTAL)
(2) PROPOSED AND (2) FUTURE VERIZON RRH'S MOUNTED TO
CUSTOM TRI-SECTOR MOUNT BEHIND SCREEN WALL
(TYP OF 4 PER SECTOR, 16 TOTAL)
PROPOSED VERIZON OVP MOUNTED TO CUSTOM TRI-SECTOR
MOUNT BEHIND SCREEN WALL
(TYP OF 1 PER SECTOR, 3 TOTAL)
GRADE
0'-0" AGL
PROPOSED VERIZON CUSTOM TRI-SECTOR MOUNT
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
3'-0"
6'-0" 2"
2'-10"
3'-0"
2'-10"
FRONT VIEW LEFT SIDE VIEW
TOP VIEW
FRONT VIEW LEFT SIDE VIEW
TOP VIEW
6'-0" 2"
2'-6"
2'-10"
2'-6" 2'-10"
4'-8"
10'-0"
10'-0" 4'-8"
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
1
Z-5
RBA72 CABINET DETAIL
SCALE: 3/4"=1'-0"
3/4 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1 0 1 2 3 4 5
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
2
Z-5
RBA72 BATTERY CABINET DETAIL
SCALE: 3/4"=1'-0"
3/4 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1 0 1 2 3 4 5
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
3
Z-5
CABINET PLINTH DETAIL
SCALE: 3/4"=1'-0"
3/4 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1 0 1 2 3 4 5
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
CONSTRUCTION
DETAILS
Z-5
8
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0097
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC OLD TOWN LIBRARY
SITE ADDRESS:
201 PETERSON ST
FORT COLLINS, CO 80524
JURISDICTION:
CITY OF FORT COLLINS
A 10-06-17 GAC 90% ZONING DRAWINGS
SHEET NUMBER:
B 05-02-18 JID 90% ZONING DRAWINGS
C 08-24-18 LCW REVISED ZONING DRAWINGS
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0097
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC OLD TOWN LIBRARY
SITE ADDRESS:
201 PETERSON ST
FORT COLLINS, CO 80524
JURISDICTION:
CITY OF FORT COLLINS
A 10-06-17 GAC 90% ZONING DRAWINGS
SHEET NUMBER:
B 05-02-18 JID 90% ZONING DRAWINGS
C 08-24-18 LCW REVISED ZONING DRAWINGS
PROPOSED VERIZON EME BARRIER
EXISTING ROOF
ENLARGED
SITE PLAN
Z-2
5
PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM
TRI-SECTOR MOUNT BEHIND SCREEN WALL
(TYP OF 4 PER SECTOR, 12 TOTAL)
PROPOSED 18'-0"x 18'-0" VERIZON LEASE AREA
(2) PROPOSED AND (2) FUTURE VERIZON
RRH'S MOUNTED TO CUSTOM TRI-SECTOR
MOUNT BEHIND SCREEN WALL
(TYP OF 4 PER SECTOR, 12 TOTAL)
PROPOSED 16'-8"x 16'-8" VERIZON CONCEALMENT WALL
PROPOSED 2'-0"x 2'-0" BRICK PAVER ON ROOFTOP
FOR ACCESS TO ALL EQUIPMENT LOCATIONS
PROPOSED HYBRID CABLE ROUTED IN EMT CONDUIT
ON 36" SLEEPERS FROM EQUIPMENT CABINETS TO
OVP'S ON TRI-SECTOR MOUNT
PROPOSED CAGED ACCESS LADDER FROM
LOWER ROOFTOP TO PENTHOUSE
PROPOSED FIBER AND POWER FROM GROUND ROUTED
ON SLEEPERS WITH CONDUIT TO EQUIPMENT CABINETS
EXISTING BRICK PAVER (TYP)
PROPOSED NEW POWER RUN FROM
EXISTING TRANSFORMER TO NEW UTILITY
METER AND DISCONNECT MOUNTED TO
EXTERIOR WALL
EXISTING ROOF ACCESS HATCH
EXISTING TRANSFORMER
(AT GRADE)
PROPOSED CHASE ON SIDE OF BUILDING FOR
FIBER AND POWER ROUTING TO EQUIPMENT
(PANT TO MATCH EXISTING BUILDING)
PROPOSED 2'-0"x3'-0" FIBER VAULT
(2) PROPOSED VERIZON EQUIPMENT
CABINETS ON STEEL SKID
PROPOSED 7'-0"x23'-0" VERIZON LEASE AREA
PROPOSED EME BARRIER
PROPOSED METER & DISCONNECT
MOUNTED ON EXTERIOR WALL
PROPOSED VERIZON CUSTOM TRI-SECTOR MOUNT
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0097
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC OLD TOWN LIBRARY
SITE ADDRESS:
201 PETERSON ST
FORT COLLINS, CO 80524
JURISDICTION:
CITY OF FORT COLLINS
A 10-06-17 GAC 90% ZONING DRAWINGS
SHEET NUMBER:
B 05-02-18 JID 90% ZONING DRAWINGS
C 08-24-18 LCW REVISED ZONING DRAWINGS
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0097
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC OLD TOWN LIBRARY
SITE ADDRESS:
201 PETERSON ST
FORT COLLINS, CO 80524
JURISDICTION:
CITY OF FORT COLLINS
A 10-06-17 GAC 90% ZONING DRAWINGS
SHEET NUMBER:
B 05-02-18 JID 90% ZONING DRAWINGS
C 08-24-18 LCW REVISED ZONING DRAWINGS
1
Z-4
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
EXISTING SIDEWALK
(TYP)
1
Z-1
SITE PLAN
SCALE: 1"=20'-0"
NOTE:
NO WIRELESS TELECOMMUNICATION FACILITY OR
EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF
SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY
OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM
USING THIS BUILDING, STRUCTURE OR LOCATION.
1 inch = 20ft.
( IN FEET )
GRAPHIC SCALE
20 0 10 20 40 80
(SCALE BASED ON FULL SIZE 24"x36" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
SITE PLAN
Z-1
4
EAST OLIVE ST.
PETERSON ST.
N
EXISTING NATURAL
GROUND (TYP)
EXISTING
BUILDING
PROPOSED VERIZON ANTENNA MOUNTED TO CUSTOM
TRI-SECTOR MOUNT BEHIND SCREEN WALL
(TYP OF 4 PER SECTOR, 12 TOTAL)
PROPOSED 2'-0"x3'-0" FIBER VAULT
(TYP OF 2) (VAULT TO BE PLACED AT EDGE
OF PROPERTY LINE. FIBER TO BE
BROUGHT TO VAULT FROM R.O.W. BY
OTHERS)
PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT
W/ 3-CELL PLENUM MAXCELL INNERDUCT
PROPOSED 10'-0" WIDE UTILITY EASEMENT
PROPOSED 18'-0"x 18'-0"
VERIZON LEASE AREA
PROPOSED 10'-0" ACCESS EASEMENT
EXISTING WALKWAY
PROPOSED CAGED ACCESS LADDER
FROM LOWER ROOFTOP TO PENTHOUSE
2 PROPOSED VERIZON EQUIPMENT
CABINETS ON STEEL SKID
PROPOSED FIBER AND POWER ROUTED
UP SIDE OF BUILDING IN CHASE
(PANT TO MATCH EXISTING BUILDING)
PROPOSED 7'-0"x 23'-0" VERIZON LEASE AREA
16. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR
TO INSTALLATION.
17. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS.
18. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL.
19. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO
EXCAVATING.
20. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT
OWNERS REPRESENTATIVE.
CITY OF FORT COLLINS NOTES:
1. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS
STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO
CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT
COLLINS STANDARDS AT THE DEVELOPERS EXPENSE PRIOR TO THE ACCEPTANCE OF
COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF
OCCUPANCY.
2. ANY PUBLIC IMPROVEMENTS MUST BE DESIGNED AND BUILT IN ACCORDANCE WITH THE LARIMER
COUNTY URBAN AREA STREET STANDARDS (LCUASS).
3. ALL FENCES, BARRIERS, POSTS OR OTHER ENCROACHMENTS WITHIN THE PUBLIC RIGHT-OF-WAY
ARE ONLY PERMITTED UPON APPROVAL OF AN ENCROACHMENT PERMIT. APPLICATIONS FOR
ENCROACHMENT PERMITS SHALL BE MADE TO THE ENGINEERING DEPARTMENT FOR REVIEW AND
APPROVAL PRIOR TO INSTALLATION. ENCROACHMENT ITEMS SHALL NOT BE SHOWN ON THE SITE
PLAN AS THEY MAY NOT BE APPROVED, NEED TO BE MODIFIED OR MOVED, OR IF THE PERMIT IS
REVOKED THEN THE SITE/LANDSCAPE PLAN IS IN NON-COMPLIANCE.
4. WITH REGARDS TO CONSTRUCTION OF THIS SITE, THE PUBLIC RIGHT-OF-WAY SHALL NOT BE USED
FOR STAGING OR STORAGE OF MATERIALS OR EQUIPMENT ASSOCIATED WITH THE
DEVELOPMENT, NOR SHALL IT BE USED FOR PARKING BY ANY CONTRACTORS,
SUBCONTRACTORS, OR OTHER PERSONNEL WORKING FOR OR HIRED BY THE DEVELOPER TO
CONSTRUCT THE DEVELOPMENT. THE DEVELOPER WILL NEED TO FIND A LOCATION(S) ON
PRIVATE PROPERTY TO ACCOMMODATE ANY NECESSARY STAGING AND/OR PARKING NEEDS
ASSOCIATED WITH THE COMPLETION OF THE DEVELOPMENT.
5. TO ASSIST WITH EMERGENCY RESPONSE, SIGNAGE SHOULD BE CLEARLY VISIBLE AT GROUND
LEVEL AND AT THE ACCESS LADDER TO INDICATE THE MOST APPROPRIATE ACCESS TO THE
VERIZON EQUIPMENT.
LEGEND
W W
SS SS SS
F F F
GAS GAS GAS GAS GAS
OE OE
UT UT
X X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD SD SD SD
E E E
UE UE UE
OT OT OT
EV
D
O O O
U/G U/G
OHW OHW
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
VERIZON COLOR STANDARDS
GRAY-EXISTING EASEMENT ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
SKYLIGHT HVAC UNIT
AC
SECURITY CAMERA VENT PIPE
VP
BOLLARD COMM DISH
TREE PROTECTION NOTES:
1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA
BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL.
2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A
FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE
DISTURBANCE.
3. ALL PROTECTED AND EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY
STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A
CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE.
4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED
EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN
HEIGHT, SECURED WITH METAL T-POST STAKES, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR
ONE-HALF (1/2) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR
MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED PROTECTION ZONE.
5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING
OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS,
OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF
A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES.
6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE.
7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION
LAND OR CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF,"
RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE. THIS MAY BE ACCOMPLISHED BY
PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE
FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREA BEING CLEARED.
8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING
EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BORING UNDER THE ROOT
SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY FOUR (24) INCHES. THE
AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE(OUTER BARK) AND IS SCALED FROM
TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW.
TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET)
0-2 1
3-4 2
5-9 5
10-14 10
15-19 12
OVER 19 15
9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1
- JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA.
JURISDICTION: CITY OF FORT COLLINS
ZONING: DOWNTOWN DISTRICT
APN: 9712321901
PARCEL SIZE: 2.92 AC
ELEVATION: 4,977 (NAVD 88)
STRUCTURE TYPE: BUILDING
STRUCTURE HEIGHT: 41'-0" (TOP OF STRUCTURE)
ANTENNA RAD CENTER: 48'-0" AGL
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: JENNIFER SCHNEIDER
3131 SOUTH VAUGHN WAY #550
AURORA, CO 80014
PH: 913-216-1695
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, CO 80301
PHONE: 720 279-8973
Z-4
EXISTING ELEVATION
REVISION SCHEDULE
REV DATE BY DESCRIPTION
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #:
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
097-17-0097
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC OLD TOWN LIBRARY
SITE ADDRESS:
201 PETERSON ST
FORT COLLINS, CO 80524
JURISDICTION:
CITY OF FORT COLLINS
A 10-06-17 GAC 90% ZONING DRAWINGS
SHEET NUMBER:
B 05-02-18 JID 90% ZONING DRAWINGS
C 08-24-18 LCW REVISED ZONING DRAWINGS
VICINITY MAP
PROPOSED ELEVATION
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM
LEGAL DESCRIPTION
A TRACT OF LAND LOCATED IN THE SOUTHWEST QUARTER OF SECTION 12, TOWNSHIP 7 NORTH,
RANGE 69 WEST OF THE SIXTH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, LARIMER COUNTY,
COLORADO, THE SAID TRACT IS ALSO LOCATED IN BLOCK 142 OF THE CITY OF FORT COLLINS AND
IS ALSO LOCATED IN THE VACATED LINCOLN PLACE.
PH-1 PHOTOSIMULATION VIEW
CENTERLINE SOLUTIONS
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
CONTACT: JEN DANIELS
PHONE: 303-550-4820
GN-1 GENERAL NOTES
Z-5 EQUIPMENT DETAILS
TITLE SHEET
T-1
1
PLANNING CERTIFICATION
APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF
THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF
___________________________, A.D.,20____.
___________________________
DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES
OWNERSHIP CERTIFICATION
_________________________________
BY _________________________________
STATE OF COLORADO )
) SS.
COUNTY OF LARIMER )
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF
___________________________, A.D.,20____,
BY __________________________.
WITNESS MY HAND AND OFFICIAL SEAL.
MY COMMISSION EXPIRES:_______________________
______________________________
NOTARY PUBLIC
SITE PLAN CERTIFICATION
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: KENT McDERMOTT
EMAIL: KENT.MCDERMOTT@VERIZONWIRELESS.COM
1. INSTALL (2) NEW EQUIPMENT CABINETS ON STEEL PLINTH ON ROOF OF BUILDING.
2. INSTALL (12) NEW ANTENNAS ON CUSTOM TRI SECTOR MOUNT.
3. (6) PROPOSED AND (6) FUTURE REMOTE RADIO HEADS ON CUSTOM TRI SECTOR MOUNT.
4. INSTALL (3) NEW OVP'S ON CUSTOM TRI SECTOR MOUNT.
5. INSTALL NEW LOAD CENTER, STEP-DOWN TRANSFORMER AND ASSOCIATED ELECTRICAL
EQUIPMENT ON ROOFTOP OF EXISTING BUILDING.
6. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT.
7. INSTALL (3) HYBRID CABLES AND ASSOCIATED COAX CABLES.
8. INSTALL NEW RF TRANSPARENT SHROUD.
PROPOSED LEASE AREA
485 S.F.