HomeMy WebLinkAboutAFFORDABLE SELF STORAGE - FDP - FDP180020 - SUBMITTAL DOCUMENTS - ROUND 1 - SITE PLANSITE PLAN NOTES
PROJECT DATA
NAME OF PROJECT:
ADDRESS:
ZIP CODE
PROPOSED USE
LEGAL DESCRIPTION
AFFORDABLE SELF STORAGE
CORNER OF CONIFER AND RED CEDAR CIRCLE
80524
SELF STORAGE
LOT 1, AFFORDABLE STORAGE OF FORT COLLINS
APPLICABLE ZONING CODE
ZONE DISTRICT:
GROSS BUILDING AREA:
TOTAL LOT SIZE:
TOTAL BUILDING COVERAGE FOOTPRINT:
FLOOR AREA RATIO:
PARKING & DRIVE AREA:
LANDSCAPE AREA:
STORMWATER DETENTION AREA:
SIDEWALK AREA:
GROSS/NET DENSITY:
(I) INDUSTRIAL DISTRICT
S1 STORAGE 95,748 SQUARE FEET
B BUSINESS (OFFICE) 1,025 SQUARE FEET
TOTAL BUILDING AREA 96,773 SQUARE FEET
140,903 SQUARE FEET (3.23 ACRES)
ZONING RESTRICTIONS ALLOWED PROPOSED
NUMBER OF STORIES - 2
APPLICABLE CODE
2012 IBC BUILDING CODE
2012 IECC ENERGY CONSERVATION
2012 IFGC FUEL GAS
2012 IPC PLUMBING
2012 IMC MECHANICAL
2012 IFC FIRE CODE
2014 NEC ELECTRICAL
BUILDING DATA
CONSTRUCTION TYPE II-B
OCCUPANCY S-1
SPRINKLERS YES NFPA-13 (2-STORY ONLY)
STANDPIPES --
FIRE DISTRICT POUDRE FIRE AUTHORITY
FLOOD HAZARD AREA NO
BUILDING HEIGHT 27'-0"
PARKING
TOTAL NUMBER OF SPACES NUMBER OF LOADING SPACES NUMBER OF ACCESSIBLE SPACES
PROVIDED: 6 PROVIDED: 2 PROVIDED: 2 REQUIRED: 1
REQUIREMENTS
.5 PER EACH EMPLOYEE MINIMUM AND .75 PER EMPLOYEE MAXIMUM
2 EMPLOYEES X .75 = 1.5 SPACES = 2 REQUIRED
APPLICABLE NOTES FROM THE DEVELOPMENT FINAL PLAN
1. ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF ALL BUILDINGS WILL BE LOCATED WITHIN 150' OF
ACCESS ROADWAY IN WHICH EMERGENCY FIRE EQUIPMENT CAN BE MANEUVERED OR THE BUILDINGS WILL BE
PROVIDED WITH AN APPROVED FIRE EXTINGUISHING SYSTEM.
2. REFER TO UTILITIES PLAN FOR LOCATION OF UTILITIES AND DRAINAGE.
3. SIDEWALKS AND RAMPS WILL CONFORM TO CITY STANDARDS.
4. PROPOSED EXTERIOR LIGHTING WILL BE POLE-MOUNTED LUMINARIES AT DRIVES AND PARKING AREAS. BOTH POLE
AND BUILDING MOUNTED FIXTURES WILL FEATURE DOWN-DIRECTIONAL AND SHARP CUTOFF LUMINARIES. ALL WALL
DN
10'
13'
168'
10'
85'
14'
10'
65'
62'
12'
40'
17'
43'
27'
52'
17'
52'
40'
11'
32'
21'
16'
21'
16'
BUILDING D
7,680 TOTAL SQ'
BLDG HEIGHT: 16'-0"
BUILDING C
6,600 TOTAL SQ'
BLDG HEIGHT: 11'-6"
BUILDING B
4,400 TOTAL SQ'
BLDG HEIGHT: 12'-0"
BUILDING A
28,809 SQ' EA. FLOOR
TOTAL= 57,618 SQ'
BLDG HEIGHT: 27'-0"
5' DETACHED SW
NEW 5' DETACHED SW
20' WIDE WROUGHT IRON LIFT
SECURITY GATE W/INTEGRATED
KNOX KEYSWITCH
BIKE RACK (4)
RED CEDAR CIRCLE
CONIFER STREET
EX. STREET TREES (5 TOTAL)
24' WIDE EMER. FIRE
ACCESS GATE
10' WIDE
LANDSCAPE
BUFFER YARD
R=15.00'
H.C. SIGN R=5.00'
24' WIDE WROUGHT IRON LIFT
SECURITY GATE W/INTEGRATED
KNOX KEYSWITCH
SITE DATA
140,903 S.F.
3.23 ACRES
2-3/8" OD SCHEDULE 40
STEEL PIPE
COLOR: CHARCOAL GRAY
FINISH
GRADE
4 TOTAL SPACES
5' - 0 1/2"
3' - 0"
1' - 5 1/2"
EXPANSION JOINT &
SEALANT
CONCRETE PIER
6" DIAMETER STEEL
BOLLARD FILLED
WITH CONCRETE
PAINTED "HIGH-
VISIBILITY YELLOW"
SLOPE T.O.
CONCRETE
9" 2' - 6" 5' - 0"
6" 6"
6"
1' - 6"
STALL SURFACE
CENTER SIGN
WITHIN PARKING
STALL AT INTERIOR
END
R7-8
2" DIAMETER METAL
PIPE WHERE WALL-
MOUNTING IS NOT
PRACTICAL
R7-201
R78b AT VAN STALLS
ABOVE STALL SURFACE
7' - 0" 6"
1"
1' - 6"
1' - 0"
3" WIDE PAINTED STRIPES AT 3'-0"
O.C.
INTERNATIONAL ACCESSIBLE
SYMBOL PER ICC/ANSI 117.1-2003
SECTION 703.6.3.1
STANDARDAISLE PARKING STALL ACCESSIBLE STALL WITH ACCESS
4" WIDE PAINTED
STRIPE (TYP.)
1. Paved with asphalt, concrete or pavers
2. Designed so that slope, measured in any
direction, and does not exceed a one (I) foot rise
to a fifty (50) foot run;
3. Designed so that whenever there is more than a
one-half (1/2) inch change in the elevation of the
surface between a handicapped accessible route
and the handicapped parking space, a ramp
shall be provided to connect the route and the
parking space.
8'-0" MIN AT VAN
9' - 0"
18' - 0"
9' - 0"
9' - 0"
18' - 0"
18' - 0"
SURFACE
NO PARKING - FIRE LANE
BIDIRECTIONAL SIGN
COMPLYING WITH D103.6
2" DIAMETER METAL PIPE
WHERE WALL-MOUNTING
IS NOT PRACTICAL
7' - 7" 1' - 6"
1' - 0"
CONTRACTOR TO
CORDINATE DIRECTIONAL
ARROW WITH FIRE
DEPARTMENT
6' - 0"
6' - 0"
FINISHED GRADE
POST TYPICAL
SQUARE PICKET
CHANNEL RAIL
22' CLEAR
24'-0" DOUBLE LEAF ORNAMENTAL SWING GATE
6' - 0"
POST TOP
RAIL BRACKET
SQUARE POST
SQUARE PICKET
U-CHANNEL RAIL
INDUSTRIAL DRIVE
RIVET
6' - 0"
FENCE LINE
LATCH
POST
FINISHED GRADE
ORNAMENTAL VERTICAL PIVOT GATE 6'-0" ORNAMENTAL FENCE DETAIL
ORNAMENTAL FENCE DETAILS ARE
TYPICAL AND WILL VARY BASED ON
FENCE MANUFACTURER
ORNAMENTAL VERTICAL PIVOT GATE PLAN
BARRIER SCREEN
CONCRETE
OPERATOR PAD
OPERATOR
PROPERTY LINE
30' LANDSCAPE
BUFFER
7
A7.5
LEVEL 1
100' - 0"
7' - 0"
6' - 0"
METAL PANEL STK2000
STRUKTUROC TEXTURED
STUCCO FINISH
COLOR: LIGHT STONE
CMU SPLITFACE BLOCK BASALITE
5608 CHARCOAL
PRECAST SILL
22 GA. PRE-FINISHED METAL
PARAPET CAP
3780 East 15th Street, Suite 201 Loveland, Colorado 80538
970.669.8220
E-mail: info@hauserarchitectspc.com HauserArchitectspc.com
SHEET
Hauser Architects, P.C. 8/10/2018 8:42:33 AM
CONIFER AND RED CEDAR CIRCLE
AFFORDABLE STORAGE OF
FORT COLLINS
ARCHITECTURAL SITE DETAILS
A3
1/2" = 1'-0"
1 BIKE RACK DETAIL - PDP
1/2" = 1'-0"
7 PIPE BOLLARD TYP. - PDP
1/2" = 1'-0"
5 ACCESSIBLE PARKING SIGNAGE - PDP
1/8" = 1'-0"
4 PARKING STALL STRIPING - PDP
1/2" = 1'-0"
6 NO PARKING - FIRE LANE SIGNAGE - PDP
1/4" = 1'-0"
3 FENCE SPEC - PDP
3/16" = 1'-0"
2 FENCE / GATE DETAIL - PDP
1/4" = 1'-0"
8 SCREEN FENCE PLAN - PDP
1/4" = 1'-0"
9 SCREEN FENCE ELEVATION - PDP
REVISIONS
PDP Submittal 01.31.2017
PDP Submittal #5 08.10.2018
1 PDP Submittal #2 03.28.2017
2 PDP Submittal #3 12.13.2017
3 PDP Submittal #4 02.16.2018
LOADING ZONE
3HR FIRE BARRIER
ENTRY / EXIT
STORAGE
EXIT
STORAGE
OVERHEAD ENTRY CANOPY
6 PARKING SPACES
EXISTING HYD.
5'-0" BIKE LANE
STRIPED AREA-VAN
ACCESSIBLE
RAMP
EXISTING CONCRETE
TO REMAIN
EXISTING SIDE WALK TO
REMAIN
EXISTING SIDE WALK TO
REMAIN
BUILDING F
18,275 TOTAL SQ'
BLDG HEIGHT: 14'-11"
3HR FIRE BARRIER
EXISTING TREES, 4"
CAL. @ 48" A.F.G.
EX. STREET TREES (5 TOTAL)
UTILITY EASEMENT
EXISTING SIDE WALK TO
REMAIN
MAN GATE W/
PANIC HARDWARE
BOLLARD, TYP.
BOLLARD, TYP.
BOLLARD, TYP.
BOLLARD, TYP.
BOLLARD, TYP.
GATE CONTROLLER
BOLLARD, TYP.
BOLLARD, TYP.
WATER
SEWER
SIGHT TRIANGLE
SIGHT TRIANGLE
FUTURE JEROME ROW
60' - 0"
3HR FIREWALL (8" CMU)
FIRE AREA 1
3,300 SF
FIRE AREA 2
3,300 SF
FIRE AREA 2
4,550 SF
FIRE AREA 3
5,000 SF
NO PARKING - FIRE
LANE RE: SITE DETAILS
TYPICAL
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
FIRE ACCESS GATE
DO NOT ENTER "EXIT
ONLY" SIGNAGE
DO NOT ENTER "EXIT ONLY"
SIGNAGE
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
PROPOSED TYPE II BUS STOP
TRANSFORT BUS STOP SIGN
5' WIDE X 8' DEEP ADA PAD
3'x6' HITCHING POST BIKE RACK
6' BENCH POWDER COATED
REFER TO TRANSFORT BUS
STOP DESIGN STANDARDS
AND GUIDELINES FOR TYPE II
BUS STOPS
NEW ROADWAY LIGHT
NEW ROADWAY LIGHT
x
x
x
x
6' METAL FENCE - POWDER COAT
BLACK
6' METAL FENCE - POWDER COAT
BLACK
6' METAL FENCE - POWDER COAT
BLACK
6' METAL FENCE -
POWDER COAT BLACK
x
6' METAL FENCE -
POWDER COAT BLACK
FDC
TRUNCATED DOMES
SIGHT TRIANGLE
SITE TRIANGLE
FIRE AREA 2
4,800 SF
FIRE AREA 1
2,880 SF
3HR FIRE BARRIER
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
KNOX BOX
9' WIDE UTILITY
EASEMENT
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE
SIGN, RE: SITE DETAILS,
TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
BUILDING E
2,200 TOTAL SQ'
BLDG HEIGHT: 16'-0"
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
30.00 ft 219.50 ft
20.00 ft
10.14 ft 5.00 ft
129.00 ft
LANDSCAPE YARD
30.00 ft
29.50 ft 30.00 ft 29.50 ft
10.56 ft 276.44 ft 20.00 ft 110.00 ft 10.05 ft
220.00 ft
20.00 ft
18.00 ft
9.00 ft
15.00 ft
2.00 ft
5.00 ft
7.45 ft
8.10 ft
5.00 ft
3HR FIRE BARRIER
85.00 ft
PROPERTY LINE
FIRE AREA 1
975 SF
FIRE AREA 4
3,500 SF
FIRE AREA 5
4,250 SF
3HR FIRE BARRIER
3HR FIRE BARRIER
3HR FIRE BARRIER
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
24.00 ft
PROPOSED SCREEN FENCE,
RE: SHEET A3 FOR ELEVATION
AND PLAN
A3
8
ENTRY / EXIT
STORAGE
ENTRY / EXIT
STORAGE
24.00 ft
7.05 ft
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
NO PARKING FIRE LANE SIGN, RE:
SITE DETAILS, TYPICAL 100' O.C.
B40 TURNING TEMPLATE
DRAINAGE EASEMENT
OFFICE ENTRY / EXIT
ANY TREE WITHIN THE SIGHT
TRIANGLES NEEDS TO BE
PRUNED A MINIMUM OF 8'-0".
LOT 4,
A MINOR SUBDIVISION PLAT OF
CONIFER INDUSTRIAL PARK
LOT 1,
UNITED WAY HOUSING
SERVICES DAY CENTER
BOLLARD, TYP.
Fire Hydrant
FDC
EAE/DE
20.00 ft
9' UTILITY EASEMENT
24' EAE
24' EAE
UE/EAE
24.00 ft
EAE
UE/EAE
EAE
24.00 ft
EAE/DE
24.00 ft
EAE/DE
24.00 ft
EAE / DE
EAE/DE
21.00 ft
DE
21.75 ft
EAE/DE
24.00 ft
EAE/DE
20.00 ft
DRAINAGE EASEMENT
DRAINAGE EASEMENT
UTILITY EASEMENT
EASTERLY TERMINUS
OF UTILITY EASEMENT
WESTERLY TERMINUS
OF UTILITY EASEMENT
9.00 ft
9' UTILITY EASEMENT
13.00 ft
13' DRAINAGE EASEMENT
DRAINAGE EASEMENT DRAINAGE EASEMENT
EAE/DE
26.00 ft
DRAINAGE EASEMENT
104 ft
X
X
X
X
X
X
X
X
X
SOLID COMPOSITE FENCE
X
X
X
3780 East 15th Street, Suite 201 Loveland, Colorado 80538
970.669.8220
E-mail: info@hauserarchitectspc.com HauserArchitectspc.com
SHEET
Hauser Architects, P.C. 8/10/2018 8:42:32 AM
CONIFER AND RED CEDAR CIRCLE
AFFORDABLE STORAGE OF
FORT COLLINS
ARCHITECTURAL SITE PLAN
A2
1" = 20'-0"
1 ARCHITECTURAL SITE PLAN - PDP
REVISIONS
PDP Submittal 01.31.2017
PDP Submittal #5 08.10.2018
1 PDP Submittal #2 03.28.2017
2 PDP Submittal #3 12.13.2017
3 PDP Submittal #4 02.16.2018
MOUNTED LIGHT FIXTURES SHALL BE FULLY SHIELDED TO CONCEAL LIGHT SOURCE.
5. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT IS TO BE FULLY SCREENED FROM PUBLIC VIEW
WITH ROOFTOP PARAPET WALLS AND LANDSCAPING. CONDUITS, METERS, VENTS AND OTHER EQUIPMENT
ATTACHED TO THE BUILDING OR PROTRUDING FROM THE ROOF SHALL BE PAINTED TO MATCH SURROUNDING
BUILDING SURFACES.
6. ALL SIGNAGE TO COMPLY WITH LOCAL SIGN CODE. SIGNS ARE NOT APPROVED WITH THIS PLAN. ALL SIGNS WILL
BE APPROVED THROUGH A SEPARATE SIGN PERMIT.
7. THE TRASH ENCLOSURES WILL BE MOUNTED ON CONCRETE AND BE CONSTRUCTED OF MATERIALS TO MATCH THE
BUILDINGS. ANY GATES CONSTRUCTED WILL BE OF SOLID MATERIAL.
8. BIKE RACKS ARE TO BE PERMANENTLY ANCHORED TO CONCRETE AND WILL NOT INTERFERE WITH PEDESTRIAN
WALKWAYS.
9. ALL HANDICAP PARKING SPACES AND RAMPS ARE TO BE VERIFIED WITH CIVIL ENGINEER FOR GRADING, DRAINAGE,
AND ACCESSIBLE ROUTE CONSIDERATIONS. HANDICAP PARKING SPACES SHOULD SLOPE NO MORE THAN 1:48 IN
ANY DIRECTION. ALL ACCESSIBLE ROUTES SHOULD SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND NO
MORE THAN 1:48 CROSS SLOPE.
10. ALL INTERNAL PEDESTRIAN WALKWAYS SHALL BE DISTINGUISHED FROM DRIVING SURFACES THROUGH THE USE OF
DURABLE LOW-MAINTENANCE SURFACE MATERIALS SUCH AS SCORED CONCRETE TO ENHANCE PEDESTRIAN
SAFETY AND COMFORT AS WELL AS THE ATTRACTIVENESS OF THE WALKWAYS.
11. ELECTRICAL TRANSFORMERS AND NATURAL GAS EQUIPMENT SHALL BE FULLY SCREENED FROM PUBLIC VIEW BY A
SOLID HEDGE OF PLANT MATERIAL OR AN ENCLOSURE MEETING THE CLEARANCE SPECIFICATIONS OF LIGHT AND
POWER. SUCH ENCLOSURE MUST MATCH THE PREDOMINATE MATERIALS OF THE BUILDING BEING SERVED.
TRANSFORMERS MUST BE WITHIN TEN FEET OF HARD SURFACE.
12. IN ORDER TO COMPLY WITH OPERATIONAL AND PHYSICAL COMPATIBILITY STANDARDS, THE OUTDOOR STORAGE OF
PRODUCTS OR MATERIALS, INCLUDING TIRE DISPLAY RACKS OR USED TIRES SHALL BE SCREENED FROM PUBLIC
VIEW. IN ADDITION, VENDING MACHINES SHALL BE PLACED INSIDE BUILDINGS OR BEHIND SCREEN WALLS.
13. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS,
SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS
PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S
EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE
FIRST CERTIFICATE OF OCCUPANCY.
14. ANY TREE WITHIN THE SIGHT TRIANGLES NEEDS TO BE PRUNED A MINIMUM OF 8'-0".
15. NO TRASH OR RECYCLING DUMPSTER WILL BE ON SITE. TRASH AND RECYCLING WILL STORED INDOORS FOR THE
USE OF THE OFFICE ONLY. THE TRASH AND RECYCLING WILL BE ROLLED OUT TO THE CURB DURING THE
SCHEDULED DELIVERY TIMES FOR CURBSIDE COLLECTION USING A 96 GALLON CART.
.68 F.A.R.
54,201 SQUARE FEET (1.2 ACRES) - 38% OF LOT
67,964 SQUARE FEET (1.56 ACRES) - 47% OF LOT
27,124 SQUARE FEET (0.49 ACRES) - 19% OF LOT
UNDERGROUND SYSTEM
6,021 SQUARE FEET (0.14 ACRES) - 4% OF LOT
NA
3780 East 15th Street, Suite 201 Loveland, Colorado 80538
970.669.8220
E-mail: info@hauserarchitectspc.com HauserArchitectspc.com
SHEET
Hauser Architects, P.C. 8/10/2018 8:42:30 AM
CONIFER AND RED CEDAR CIRCLE
AFFORDABLE STORAGE OF
FORT COLLINS
COVER SHEET
A1
Project Development Plan (PDP)
SHEET
NUMBER SHEET NAME
E-2 PHOTOMETRIC DETAILS
A1 COVER SHEET
A2 ARCHITECTURAL SITE PLAN
A3 ARCHITECTURAL SITE DETAILS
A4 BUILDING A ELEVATIONS
A5 BUILDING B & C ELEVATIONS
A6 BUILDING D & E ELEVATIONS
A7 BUILDINGS F ELEVATIONS
A8 PERSPECTIVES
A9 DIGITAL MATERIAL BOARD
L-1 LANDSCAPE PLAN
L-2 LANDSCAPE NOTES AND DETAILS
L-3 MITIGATION NOTES
L-4 IRRIGATION PLAN
L-5 IRRIGATION NOTES AND DETAILS
CONTACT:
CONTACT NAME:
PH:
ARCHITECT:
HAUSER ARCHITECTS PC
3780 EAST 15TH STREET
LOVELAND, CO 80538
970.669.8220
AL HAUSER
al@hauserarchitectspc.com
CONTACT:
CONTACT NAME:
PH:
CIVIL ENGINEER:
NORTH STAR DESIGN, INC.
700 AUTOMATION DRIVE, UNIT 1
WINDSOR, CO 80550
970.686.6939
PATRICIA KROETCH
tricia@northstardesigninc.com
PH:
CONTACT:
OWNER:
RANDY AND DEB MILAN
1402 CATALPA COURT
FORT COLLINS, CO 80521
970-566-0708
debmilan@aol.com
AFFORDABLE STORAGE OF FORT COLLINS
PROJECT DEVELOPMENT PLAN (PDP)
BEING A REPLAT OF A PORTION OF LOTS 7 & 8 AND ALL OF LOT 9, BLOCK 4, REPLAT NO. 1 OF EVERGREEN PARK AND
LOT 1, A MINOR SUBDIVISION PLAT OF CONIFER INDUSTRIAL PARK, ALL SITUATE IN SECTION 1, TOWNSHIP 7 NORTH,
RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
CONTACT:
CONTACT NAME:
PH:
ELECTRICAL ENGINEER:
BRET'S ELECTRIC, LLC
9250 BRUIN BLVD., UNIT C
FREDERICK, CO 80530
720.494.8944
JUSTIN MARTIN
JUSTIN@BRETSELECTRIC.COM
OWNER'S CERTIFICATION
The undersigned does/do herby certify that I/we are the lawful
owners of real property described on this site plan and do hereby certify
that I/we accept the conditions and restrictions set forth on said site
plan.
_____________________
Owner (signed) Date
(State of _________________)
(County of ________________)
Subscribed and sworn to before me this ________day of
_____________, 20__A.D. by
WITNESS my hand and official seal.
_______________________
Notary Public
_________________________________________________________
Address
_______________________
My Commission Expires
DIRECTOR OF COMMUNITY DEVELOPMENT AND
NEIGHBORHOOD SERVICES
Approved by the Director of Planning of the City of Fort Collins, Colorado, this
________________ day of _____________, 20___ A.D.
_________________________________________________
Director of Community Development and Neighborhood Services
VICINITY MAP
SHEET NOTE HEADING
SITE
PH:
CONTACT:
LANDSCAPE ARCHITECT:
SITE DESIGN, LLC
P.O Box 51
LOVELAND, CO 80539
970-217-9169
info@sitedesign-llc.com
CONTACT:
FAX:
PH:
GENERAL CONTRACTOR:
MCCAULEY CONSTRUCTORS
650 INNOVATION CIRCLE
WINDSOR, CO 80550
970-686-6300
970-686-6320
LEON@MCCAULEYCONSTRUCTORS.COM
AFFORDABLE STORAGE OF FORT COLLINS
UNIT SCHEDULE 2 STORY VS. SINGLE STORY
TYPE COUNT
UNIT
AREA
TOTAL
UNIT AREA
PERCENTAGE
MIX
2 STORY
5 x 5 37 25 SF 925 SF 5.9%
5 x 10 87 50 SF 4350 SF 13.8%
5 x 12 1 60 SF 60 SF 0.2%
10 x 10 153 100 SF 15300 SF 24.2%
10 x 15 76 150 SF 11400 SF 12.0%
10 x 20 51 200 SF 10200 SF 8.1%
10 x 25 2 250 SF 500 SF 0.3%
2 STORY:
407
407 42735 SF
5 x 4 1 20 SF 20 SF 0.2%
5 x 5 5 25 SF 125 SF 0.8%
5 x 10 12 50 SF 600 SF 1.9%
9 x 20 1 180 SF 180 SF 0.2%
10 x 4 1 40 SF 40 SF 0.2%
10 x 10 47 100 SF 4700 SF 7.4%
10 x 13 4 130 SF 520 SF 0.6%
10 x 15 55 150 SF 8250 SF 8.7%
10 x 18 4 180 SF 720 SF 0.6%
10 x 20 65 200 SF 13000 SF 10.3%
10 x 21 5 210 SF 1050 SF 0.8%
10 x 25 19 250 SF 4750 SF 3.0%
10 x 30 3 300 SF 900 SF 0.5%
15 x 15 1 225 SF 225 SF 0.2%
15 x 25 1 375 SF 375 SF 0.2%
35 x 20 1 700 SF 700 SF 0.2%
: 225 225 36155 SF
Grand total:
632
632 78890 SF
REVISIONS
PDP Submittal 01.31.2017
PDP Submittal #5 08.10.2018
1 PDP Submittal #2 03.28.2017
2 PDP Submittal #3 12.13.2017
3 PDP Submittal #4 02.16.2018