Loading...
HomeMy WebLinkAboutELITE INFUSED (5724 S. COLLEGE AVE.) - BASIC DEVELOPMENT REVIEW ..... BACKGROUND DOCUMENTS - BDR180013 - SUBMITTAL DOCUMENTS - ROUND 2 - FIRE AUTHORITY REQUIREMENTS9/12/2018 Feller Civil Consulting LLC Mail - Fire Access Exhibit- Elite Infused BDR180013 https://mail.google.com/mail/u/0/?ui=2&ik=145022a6b9&jsver=jOJ3TkC6zfU.en.&cbl=gmail_fe_180904.11_p6&view=pt&msg=1645caacda714446&q=… 1/3 Daniel Feller <dfeller@fellercivil.com> Fire Access Exhibit- Elite Infused BDR180013 Andrew Rosen <arosen@poudre-fire.org> Mon, Jul 2, 2018 at 2:23 PM To: Daniel Feller <dfeller@fellercivil.com> Hi Dan My apologies, I was out of the office last week so today’s my first day back. The new firetruck turn exhibit is acceptable. The other outstanding issue is the addressing and wayfinding for the facility since it is behind the residence. Per our mee ng at the City, the address including number and street name should be a ached to the eleva on facing College Avenue in 12” numbers and le ers. I hope you have a great week Andrew From: Daniel Feller [mailto:dfeller@fellercivil.com] Sent: Sunday, July 01, 2018 7:15 PM To: Andrew Rosen Subject: Re: Fire Access Exhibit- Elite Infused BDR180013 Andrew Any feedback yet on the updated equipment access and grades showing in the exhibit? Thanks Daniel Feller P.E. Feller Civil Consulting 970 646 4255 office 970 617 3769 mobile On Thu, Jun 21, 2018 at 12:54 PM, Daniel Feller <dfeller@fellercivil.com> wrote: I just realized that and sent. 9/12/2018 Feller Civil Consulting LLC Mail - Fire Access Exhibit- Elite Infused BDR180013 https://mail.google.com/mail/u/0/?ui=2&ik=145022a6b9&jsver=jOJ3TkC6zfU.en.&cbl=gmail_fe_180904.11_p6&view=pt&msg=1645caacda714446&q=… 2/3 Thanks Daniel Feller P.E. Feller Civil Consulting 970 646 4255 office 970 617 3769 mobile On Thu, Jun 21, 2018 at 12:52 PM, Andrew Rosen <arosen@poudre-fire.org> wrote: Hi Daniel I did not receive the site plan a achment Andrew From: Daniel Feller [mailto:dfeller@fellercivil.com] Sent: Thursday, June 21, 2018 12:50 PM To: Andrew Rosen Subject: Fire Access Exhibit- Elite Infused BDR180013 Mr. Rosen I am following up with a more detailed exhibit showing how a PFA fire truck can access the referenced site and building. This is related to comment #3 of your 5/25/18 review comments. Although portions of the site are greater than 10% a design vehicles fire truck does not need to traverse an area of grades greater than 10% to gain the specified access to the buildings. The attached site plan shows the PFA design vehicle and grades along the tire travel paths. The grades shown are those that the vehicle will experience based on its wheel base length. The exhibit demonstrates the design fire vehicle can drive into the site on the existing pavements within the proposed fire easement access to a point close enough to the building so that all points are within 150' of the fire vehicle. Bold red line shows the 150' along the ground path from the truck to the building. If you have any questions or need further clarification please contact me. Once you have had a chance to review this please let me know if this is sufficient to resubmit with the assumption that comment #3 will be addressed with no need to sprinkler or modify the existing pavements. 9/12/2018 Feller Civil Consulting LLC Mail - Fire Access Exhibit- Elite Infused BDR180013 https://mail.google.com/mail/u/0/?ui=2&ik=145022a6b9&jsver=jOJ3TkC6zfU.en.&cbl=gmail_fe_180904.11_p6&view=pt&msg=1645caacda714446&q=… 3/3 Respectfully Daniel Feller P.E. Feller Civil Consulting 970 646 4255 office 970 617 3769 mobile