HomeMy WebLinkAboutSPRADLEY BARR REDEVELOPMENT - PDP - PDP180010 - SUBMITTAL DOCUMENTS - ROUND 1 - UTILITY PLANS (3)SOUTH COLLEGE AVE. WEST DRAKE ROAD EAST DRAKE ROAD WEST THUNDERBIRD DRIVE McCLELLAND DRIVE JULY 2018 I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design. revisions, and record conditions that I have noted on these plans. These plans have been reviewed by the City of Fort Collins for concept only. The review does not imply responsibility by the reviewing department, the City of Fort Collins Engineer, or the City of Fort Collins for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed for any reason as acceptance of financial responsibility by the City of Fort Collins for additional quantities of items shown that may be required during the construction phase. DISCLAIMER STATEMENT: CERTIFICATION STATEMENT: VICINITY MAP NORTH 1"=500' PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 21-92 Northwest corner of West Drake Rd. and Research Blvd., on a power tower base. Elev.= 5042.84 City of Fort Collins Benchmark 14-97 Approximately 100 feet west of the intersection of Centre Ave. and Research blvd.,on the west end of the south headwall on Centre Ave. Elev.= 5051.76 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.17' Basis of Bearings The Basis of Bearings is the North line of the Northeast Quarter, Section 26-7-69, as bearing N 89°30' W. Northern Engineering Project No. 249-015 Date: February 2012 Additional Topo: Northern Engineering Project No. 379-072 Date: November 2017 Northern Engineering Project No. 379-072 Date: May 2018 ORIGINAL FIELD SURVEY BY: PROJECT BENCHMARKS: CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R OWNER/APPLICANT CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 C002 E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E BUS BUS LID T X C TF TF TF TF TF DRAKE ROAD (ROW VARIES) McCLELLAND DRIVE (37' ROW) COLLEGE AVENUE (ROW VARIES) THUNDERBIRD DRIVE (60' ROW) PROPOSED ACCESS RAMP PROPOSED ACCESS RAMPS PROPOSED ACCESS RAMPS PROPOSED STRIPING SEE SHEET C500 15' 8' 15' 24' EMERGENCY ACCESS EASEMENT 24' EMERGENCY ACCESS EASEMENT 24' EMERGENCY ACCESS EASEMENT ENCHANTE ENTERPRISES LLC 2631 S COLLEGE AVE PLUTUS HOLDINGS LLC 2633 S COLLEGE AV. 24' FL-FL RAISED CROSSWALK RAISED CROSSWALK RAISED CROSSWALK RAISED CROSSWALK RAISED CROSSWALK 19' 9' 9' 9' 19' 17' 9' 17' 9' 19' 9' 8' 5' 8' E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G E E E E E W W W W W W W W W W W W W W W W W W W W W W W G G CTV E E E E E E E E E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV G G G G G G G G G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E W W W W W W W W W W W W W W W W W W W W W W W E E E E E E E E E E E E E E E SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE H2O S WV S VAULT ELEC TF TF TF LOT 5 LOT 3 LOT 2 TRACT B W W W W W W S S S F F W W E E E E E E E E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV G G G G G G G G G G G G G G G G G G G G G G SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS X X S S C S W W W W W W W W W W W W W W W W W W W W W W W H Y D TF LOT 2 LOT 1 TRACT A S W F W TRACT B THUNDERBIRD DRIVE (60' ROW) PLUTUS HOLDINGS LLC McCLELLAND DRIVE (37' ROW) PLUTUS HOLDINGS LLC 2633 S COLLEGE AV. EXMH 5 INV. IN=5017.32 (N) INV. OUT=5018.33 (E) FG=5030.02 EXMH 4 INV. IN=5017.12 (W) INV. OUT=5017.10 (E) FG=5027.14 BLDG A SERV INV. OUT=5017.75 (S) FG=5031.61 43.37 LF 6" PVC E E E E E E E E E E E E E E E E E E E E E E E E E E E E G G G G G G G G G G G G G G W W E E E E E E E E W W W W W W W W W W W W W W W W W CTV CTV SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS LID T OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE S ELEC MH C S VAULT ELEC S ELEC WV WV H2O WV W W W W D D D W W D ST ST ST ST D TF LOT 6 S S W W F LOT 5 TRACT B TRACT B LID T X C D D D D D ST ST D TF TF TF TF TF EXISTING 15" RCP STORM DRAIN PROPOSED STORM DRAIN PROPOSED INLET CONNECT TO EXISTING STORM DRAIN CONNECT TO EXISTING STORM DRAIN PROPOSED INLET PROPOSED WATER QUALITY CHAMBERS PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED STORM DRAIN ENCHANTE ENTERPRISES LLC 2631 S COLLEGE AVE PLUTUS HOLDINGS LLC 2633 S COLLEGE AV. DRAKE ROAD (ROW VARIES) McCLELLAND DRIVE (37' ROW) COLLEGE AVENUE (ROW VARIES) THUNDERBIRD DRIVE (60' ROW) LOT 6 TRACT B LOT 5 LOT 3 TF DRAKE ROAD (ROW VARIES) 15' UTILITY EASEMENT 9' UTILITY EASEMENT (29.32) (30.10) (30.34) McCLELLAND DRIVE (37' ROW) 29.96 28.53 28.47 27.30 27.24 27.85 27.26 26.00 25.94 LOT 3 26' EMERGENCY ACCESS EASEMENT 12' SIDEWALK WAYFINDING SIGN 6' SIDEWALK FFE=30.95 FFE=30.18 26.15 30.18 30.95 30.96 30.96 30.93 30.73 30.83 30.69 30.20 ??? 29.84 (29.45) 29.15 (29.81) (29.81) PROPOSED ACCESS RAMP PROPOSED ACCESS RAMP 31.08 31.10 30.93 30.88 30.69 30.83 30.83 30.18 30.06 30.18 30.18 30.95 TF TF PROPOSED INLET PROPOSED INLET 15' UTILITY EASEMENT DRAKE ROAD (ROW VARIES) 24.93 24.88 24.47 24.45 24.36 24.22 24.13 24.16 24.09 LOT 5 TRACT B TRACT A RAISED CROSSWALK RAISED CROSSWALK 26' EMERGENCY ACCESS EASEMENT 24' FL-FL 5' WALK 6' SIDEWALK WAYFINDING SIGN PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) 6' SIDEWALK FFE=30.18 FFE=27.00 28.99 24.70 24.55 24.39 24.23 24.79 24.83 26.01 25.66 26.91 27.51 26.61 26.70 26.95 26.86 27.00 26.34 25.38 26.40 26.30 25.28 LID D D ST ST ST ST ST ST D COLLEGE AVENUE (ROW VARIES) EXISTING 15" RCP STORM DRAIN PROPOSED INLET PROPOSED STORM DRAIN 6' UTILITY & ACCESS EASEMENT (21.34) (21.85) DRAKE ROAD (ROW VARIES) 21.64 21.55 21.46 21.50 21.28 LOT 5 TRACT B UTILITY EASEMENT (WIDTH VARIES) 6' UTILITY & ACCESS EASEMENT 15' UTILITY EASEMENT 6' SIDEWALK 12' SIDEWALK FFE=27.00 PROPOSED ACCESS RAMP PROPOSED STAIRS PROPOSED STAIRS PROPOSED STAIRS PROPOSED STAIRS 23.89 24.01 23.90 27.00 26.34 27.00 23.22 23.16 22.29 22.23 22.10 22.18 22.35 26.34 26.82 27.00 27.00 27.00 McCLELLAND DRIVE (37' ROW) (30.34) (30.67) (30.58) LOT 2 TRACT A 24' EMERGENCY ACCESS EASEMENT 12' SIDEWALK 24' FL-FL 24' EMERGENCY ACCESS EASEMENT 4' WALK (TYP.) WAYFINDING SIGN 9' UTILITY EASEMENT FFE=33.00 28.67 28.80 30.12 33.00 33.00 31.26 32.20 33.00 31.78 31.63 31.05 30.91 30.00 29.89 28.99 31.37 33.00 33.00 32.88 32.88 31.41 31.43 32.88 32.88 33.00 33.00 33.00 32.88 32.88 31.51 31.50 32.88 33.00 32.88 33.00 32.88 31.58 31.60 32.88 32.88 33.00 TF PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED STORM DRAIN TRACT B TRACT A TRACT A RAISED CROSSWALK RAISED CROSSWALK 24' EMERGENCY ACCESS EASEMENT 24' FL-FL 24' EMERGENCY ACCESS EASEMENT PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED WATER QUALITY CHAMBERS 28.99 25.78 25.88 26.04 25.90 26.06 25.82 26.23 26.25 28.16 28.04 28.19 26.19 28.91 28.83 28.37 28.83 28.43 28.20 28.10 28.78 28.75 29.07 28.47 28.69 28.62 28.71 28.62 28.39 28.46 28.72 28.87 29.17 29.04 28.78 T C D D TF EXISTING 15" RCP STORM DRAIN PROPOSED WATER QUALITY CHAMBERS PROPOSED INLET PROPOSED INLET UTILITY EASEMENT (WIDTH VARIES) 6' UTILITY & ACCESS EASEMENT COLLEGE AVENUE (ROW VARIES) (22.42) (22.25) TRACT B LOT 6 RAISED CROSSWALK 24' EMERGENCY ACCESS EASEMENT 12' SIDEWALK 12' SIDEWALK TYPE III BARRICADES 6' UTILITY & ACCESS EASEMENT FFE=27.00 PROPOSED STAIRS 25.84 25.86 26.14 26.20 26.50 26.27 26.15 25.98 26.14 26.19 25.17 25.28 25.40 27.00 25.17 27.25 26.37 26.24 26.22 26.26 26.30 26.37 26.87 27.00 27.00 27.00 THUNDERBIRD DRIVE (60' ROW) McCLELLAND DRIVE (37' ROW) 9' UTILITY EASEMENT 9' UTILITY EASEMENT (30.58) (29.94) LOT 1 PROPOSED ACCESS RAMP 24' EMERGENCY ACCESS EASEMENT 12' SIDEWALK 5' SIDEWALK 4' WALK (TYP.) PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) FFE=33.00 30.60 31.27 31.35 31.65 30.92 31.90 31.95 31.33 31.17 30.83 30.66 30.83 31.50 31.57 32.82 32.88 32.96 32.70 31.82 31.81 32.80 32.10 32.01 28.78 28.75 29.34 30.09 29.07 32.88 32.88 31.47 31.49 31.38 31.36 31.20 31.27 31.26 31.15 X X X TF PROPOSED INLET THUNDERBIRD DRIVE (60' ROW) (26.14) TRACT A 24' EMERGENCY ACCESS EASEMENT 24' FL-FL RAISED CROSSWALK 5' SIDEWALK 9' UTILITY EASEMENT 28.78 28.75 29.07 28.21 28.05 27.83 27.91 27.61 27.62 28.19 28.54 27.68 27.77 28.10 28.66 27.56 27.55 27.48 30.20 29.26 27.99 28.19 28.08 28.05 27.63 27.46 27.30 27.47 28.88 27.95 27.86 28.77 28.98 29.69 29.62 29.15 28.86 28.93 28.70 28.63 28.63 28.72 28.67 28.02 BUS TF 55' LANE SHIFT (2' @ 40 MPH) 10' DEEP BUS PULL OUT 6' ATTACHED WALK 170' 10' PARKWAY 50' EXISTING PRPA TRANSMISSION POLE (MIN. 30" CLEARANCE PROVIDED) DRAKE ROAD (ROW VARIES) McCLELLAND DRIVE (37' ROW) BURLINGTON NORTHERN RAILROAD PROPOSED ACCESS RAMPS 6' SIDEWALK WAYFINDING SIGN PROPOSED 30" VERTICAL CURB & GUTTER 15' EASEMENT EXISTING 18" VERTICAL CURB & GUTTER EXISTING STRIPING EXISTING STRPING 15' EASEMENT LOT 3 LOT 4 12 12 8 8 16' TRAVEL LANE 6 ±11' TRAVEL LANE 145' TAPER (12' @ 40 MPH) 310' TOTAL LENGTH (40 MPH = 315') 8' PARKWAY 11' THRU LANE 6' WALK 11' THRU LANE 145' TAPER (12' @ 40 MPH) 165' BAY 11' LEFT TURN 11' RIGHT TURN 15' EASEMENT 46' 20' 11' LEFT TURN 6' BIKE LANE 310' TOTAL LENGTH (40 MPH = 315') EXISTING SIGNAL WITHIN ISLAND 1.6' COLLEGE AVENUE (ROW VARIES) PROPOSED LID T X C D D D D D ST ST D TF TF TF TF TF DRAKE ROAD (ROW VARIES) McCLELLAND DRIVE (37' ROW) COLLEGE AVENUE (ROW VARIES) THUNDERBIRD DRIVE (60' ROW) CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF CF PROPOSED STORM DRAIN CONNECT TO EXISTING STORM DRAIN CONNECT TO EXISTING STORM DRAIN PROPOSED WATER QUALITY CHAMBERS PROPOSED STORM DRAIN PROPOSED STORM DRAIN LOT 1 LOT 2 LOT 3 LOT 4 LOT 6 LOT 5 TRACT B TRACT A TRACT A TRACT A VTC CWA No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C601 LID T X C D D D D D ST ST D TF TF TF TF TF CHAMBER WQ AREA REQUIRED VOLUME: 7,332 CF PROVIDED VOLUME: 7,565 CF 3 0.23 ac 2 0.56 ac 1 1.01 ac 7 0.77 ac 6 0.81 ac 5 1.88 ac 9 0.46 ac 2 1 3 8 10 6 5 4 10 0.45 ac 4 0.29 ac 8 0.63 ac 7 9 PROPOSED STORM DRAIN PROPOSED INLET CONNECT TO EXISTING STORM DRAIN CONNECT TO EXISTING STORM DRAIN PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED STORM DRAIN ENCHANTE ENTERPRISES LLC 2631 S COLLEGE AVE PLUTUS HOLDINGS LLC 2633 S COLLEGE AV. DRAKE ROAD (ROW VARIES) McCLELLAND DRIVE (37' ROW) COLLEGE AVENUE (ROW VARIES) THUNDERBIRD DRIVE (60' ROW) PROPOSED INLET No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C700 DRAINAGE EXHIBIT A. Reese B. Ruch 1"=30' 21 NORTH ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION LEGEND: 4953 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET DESIGN POINT A FLOW ARROW DRAINAGE BASIN LABEL DRAINAGE BASIN BOUNDARY PROPOSED SWALE SECTION 1 1 NOTES: 1. REFER TO THE PRELIMINARY DRAINAGE REPORT FOR DRAKE REDEVELOPMENT, DATED JULY 25, 2018 FOR ADDITIONAL INFORMATION. BASIN DESIGNATION AREA BASIN (AC) BENCHMARK FOR DRAINAGE REVIEW ONLY NOT FOR CONSTRUCTION C 0.60 ac LID SUMMARY: RUNOFF TABLE: PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 21-92 NORTHWEST CORNER OF WEST DRAKE RD. AND RESEARCH BLVD., ON A POWER TOWER BASE. ELEV.= 5042.84 CITY OF FORT COLLINS BENCHMARK 14-97 APPROXIMATELY 100 FEET WEST OF THE INTERSECTION OF CENTRE AVE. AND RESEARCH BLVD.,ON THE WEST END OF THE SOUTH HEADWALL ON CENTRE AVE. ELEV.= 5051.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE NORTH LINE OF THE NORTHEAST QUARTER, SECTION 26-7-69, AS BEARING N 89°30' W. DRAKE REDEVELOPMENT ON-SITE LID TREATMENT Project Summary Total Impervious Area 230,699 sf Target Treatment Percentage 75% Minimum Area to be Treated by LID measures 173,024.27 sf Chamber Isolator Rows Total Chaamber Treatment Area 210,907 sf Total Treatment Area 210,907 sf Percent Total Project Area Treated 91.4% Basin ID Basin Area (s.f.) Basin Area (ac) Composite % Imperv. Flow, WQ (cfs) Flow, Q2 (cfs) Flow, Q100 (cfs) Treatment Area (sf) 1 1.01 5.28 0.42 0.70 1.39 6.23 20313.00 2 0.56 0.00 0.42 0.36 0.73 3.23 11256.00 3 0.23 0.00 0.36 0.17 0.34 1.49 3870.00 4 0.29 0.00 0.38 0.22 0.43 1.90 5565.41 5 1.88 0.00 0.89 2.44 4.89 18.71 77504.47 6 0.81 0.00 0.82 0.99 1.98 8.03 30754.42 7 0.77 0.00 0.80 0.93 1.86 7.63 29367.31 8 0.63 0.00 0.86 0.81 1.62 6.23 25969.36 9 0.46 0.00 0.38 0.34 0.69 3.00 7836.15 10 0.45 0.00 0.81 0.53 1.07 4.43 16430.24 EROSION CONTROL DETAILS A. Reese B. Ruch N/A 20 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R VEHICLE TRACKING CONTROL PAD SHALL BE LOCATED AT EVERY ACCESS POINT TO THE CONSTRUCTION SITE. A SIGN SHALL BE PLACED NEXT TO THE VEHICLE TRACKING CONTROL PAD TO DESIGNATE THE LOCATION AS THE CONSTRUCTION ENTRANCE/EXIT. VEHICLE TRACKING CONTROL PADS SHALL CONSIST OF HARD, DENSE, DURABLE STONE, ANGULAR IN SHAPE AND RESISTANT TO WEATHERING. ROUNDED STONE (i.e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x4'S, PIPES, DIRT, GRAVEL OR ASPHALT, SHALL BE PLACED IN GUTTER TO FACILITATE MOUNTING CURB; HOWEVER, CURB MAY BE CUT DOWN TO A HEIGHT OF 2" OR HIGHER FOR EASIER ACCESS AND REPLACED AT PROJECT COMPLETION. OTHER ACCESS DEVICES MAY BE USED AS ACCEPTED BY THE CITY. 3" - 6" ROCK CURB CUT 50' MIN. 2" MIN. 6" MIN. 6" MIN. ALTHOUGH NOT NORMALLY USED, THE CITY RESERVES THE RIGHT TO REQUIRE VEHICLE TRACKING CONTROL WITH A TEMPORARY CATTLE GUARD AND/OR WHEEL WASH FACILITIES AT SITES WHERE TRACKING ONTO PAVED AREAS BECOMES A SIGNIFICANT PROBLEM AS DETERMINED BY THE CITY INSPECTOR. IF VEHICLE TRACKING CONTROL WITH WHEEL WASH FACILITIES ARE REQUIRED, ALL WHEELS ON EVERY VEHICLE LEAVING THE SITE SHALL BE CLEANED OF MUD USING A PRESSURE-WASHER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A WATER SOURCE AND CONSTRUCTING A WASHWATER SEDIMENT TRAP. 5. 6. IF VEHICLE WHEEL WASH FACILITIES ARE REQUIRED, CONTRACTOR SHALL INSPECT VEHICLE TRACKING CONTROL AND WHEEL WASH FACILITIES DAILY. ACCUMULATED SEDIMENTS SHALL BE REMOVED FROM THE PAD SURFACE. ACCUMULATED SEDIMENT IN THE WASHWATER/SEDIMENT TRAP SHALL BE REMOVED WHEN THE SEDIMENT REACHES AN AVERAGE DEPTH OF 12-INCHES. 4. 5. VTC 0" ON BEDROCK OR HARD SURFACE, 2" IN SOIL ROCK SOCK SECTION ROCK SOCK PLAN 4" TO 6" MAX AT CURBS, OTHERWISE 6"-10" DEPENDING ON EXPECTED SEDIMENT LOADS ROCK SOCK JOINTING \A1;12" \A1;12" {ROCK SOCK INSTALLATION NOTES }1.SEE PLAN VIEW FOR: - LOCATION (S) OF ROCK SOCKS. 2.CRUSHED ROCK SHALL BE 1{}" (MINUS) IN SIZE WITH A FRACTURED FACE (ALL SIDES) AND SHALL COMPLY WITH GRADATION SHOWN ON THIS SHEET (1{}" MINUS). 3.WIRE MESH SHALL BE FABRICATED OF 10 GAGE POULTRY MESH, OR EQUIVALENT, WITH A MAXIMUM OPENING OF {}", RECOMMENDED MINIMUM ROLL WIDTH OF 48". 4.WIRE MESH SHALL BE SECURED USING "HOG RINGS" OR WIRE TIES AT 6" CENTERS ALONG ALL JOINTS AND AT 2" CENTERS ON ENDS OF SOCKS. 5.SOME MUNICIPALITIES MAY ALLOW THE USE OF FILTER FABRIC AS AN ALTERNATIVE TO WIRE MESH FOR THE ROCK ENCLOSURE. GRADATION TABLE SIEVE SIZE MASS PERCENT PASSING SQUARE MESH SIEVES NO. 4 2" 100 1-1/2" 90-100 1" 20-55 3/4" 0-15 3/8" 0-5 MATCHES SPECIFICATIONS FOR NO. 4 COARSE AGGREGATE FOR CONCRETE PER AASHTO M43. ALL ROCK SHALL BE FRACTURED FACE, ALL SIDES WIRE ENCLOSED 1 1/2" WASHED ROCK CURB AND GUTTER TUBULAR MARKER \A1;2' RS NOT TO SCALE 001 C601 CONCRETE WASHOUT AREA NOT TO SCALE 002 C601 ROCK SOCK NOT TO SCALE 003 C601 VEHICLE TRACKING BAG NOT TO SCALE 004 C601 CONSTRUCTION FENCE w/ ROCK SOCKS TEMPORARY CHAIN-LINK FENCE ROCK SOCK TEMPORARY CHAIN-LINK FENCE ROCK SOCK SIDE VIEW CF 1.CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY CONCRETE PLACEMENT ON SITE. 2.VEHICLE TRACKING CONTROL IS REQUIRED IF ACCESS TO CONCRETE WASHOUT AREA IS OFF PAVEMENT. 3.SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS. 4.THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY FOR WASTED CONCRETE. 5.THE CONCRETE WASHOUT SHOULD BE EMPTIED WHEN HALF OF TOTAL HOLDING CAPACITY HAS BEEN REACHED. 6.AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF AT AN ACCEPTED WASTE SITE. 7.WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED IN A MANNER ACCEPTED BY THE CITY. 8.LOCATION OF CONCRETE WASHOUT AREA ON SHEET EC1 IS CONCEPTUAL ONLY. FINAL LOCATION TO BE DETERMINED IN THE FIELD AT CONTRACTOR'S DISCRETION. {\LNOTES:} 3H:1V OR FLATTER SIDE SLOPES \A1;12" MIN 8'x 8' MIN OR AS REQUIRED TO CONTAIN WASTE CONCRETE \A1;12" \A1;2'-0" MIN. COMPACTED EMBANKMENT MATERIAL, TYP. BERM AROUND PERIMETER GROUND SURFACE SIGN TO INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA CWA * IMPERMEABLE LINER MAY BE NEEDED IF GROUND WATER IS ENCOUNTERED. MANHOLE ROCK BERM SHALL 2"x 4" WOOD STUD EXTENDED INTO CONCRETE BLOCKS WIRE ENCLOSED 1 1/2" WASHED ROCK CONCRETE BLOCKS CURB INLET GRAVEL FILTER WIRE SHALL ENCLOSED BE 2"x4" WOOD STUD OVERFLOW FILTERED RUNOFF %%uSECTION A-A A A %%uPLAN VIEW {CURB INLET GRAVEL FILTER (CONTINUOUS GRADE)} %%uSECTION B-B %%uPLAN VIEW B B ROCK BERM SHALL BE PLACED TIGHTLY AGAINST CURB FACE WIRE ENCLOSED 1 1/2" WASHED ROCK CURB AND GUTTER CURB AND GUTTER BE PLACED TIGHTLY AGAINST CURB FACE GRAVEL FILTER 1/2" TO 1" BELOW TOP OF CURB TUBULAR MARKER IF AREA ADJACENT TO CURB INLET BOX IS NOT STABILIZED, INSTALL A TEMPORARY SEDIMENT/EROSION CONTROL BMP UNTIL THE SURROUNDING AREA IS SUFFICIENTLY STABILIZED. TUBULAR MARKER TUBULAR MARKER \A1;3' \A1;2' CURB INLET WIRE ENCLOSED SETTLED RUNOFF GRAVEL FILTER CURB INLET MANHOLE {CURB INLET BLOCK AND GRAVEL FILTER (INLET IN SUMP)} INTERIM CONFIGURATION INLET PROTECTION IN STREETS SHALL BE INSTALLED WITHIN 48 HOURS OF POURING INLET. INLET PROTECTION (AFTER PAVING) SHALL BE INSTALLED WITHIN 48 HOURS AFTER PAVING IS PLACED. WASHED ROCK SHALL COMPLY WITH A 1-1/2" MINUS GRADATION. WIRE MESH SHALL BE FABRICATED OF 10 GAUGE WIRE TWISTED INTO A MESH WITH A MAXIMUM OPENING OF 1" (COMMONLY TERMED "CHICKEN WIRE"). ROLL WIDTH SHALL BE 48". TUBULAR MARKERS SHALL MEET REQUIREMENTS OF MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). OTHER CURB INLET PROTECTION METHODS WILL BE ALLOWED IF ACCEPTED BY THE CITY. {GENERAL NOTES: }1. 2. 3. 4. 5. THE CONTRACTOR SHALL INSPECT INLET PROTECTION EVERY TWO WEEKS AND AFTER SIGNIFICANT STORM EVENTS AND MAKE REPAIRS OR CLEAN OUT AS NECESSARY. SEDIMENT ACCUMULATED UPSTREAM OF INLET PROTECTION SHALL BE REMOVED WHEN THE SEDIMENT DEPTH UPSTREAM OF ROCK BERM IS 2 1/2" OF THE CREST. INLET PROTECTION IS TO REMAIN IN PLACE UNTIL THE UPSTREAM DISTURBED AREA IS STABILIZED AND GRASS COVER IS ACCEPTED. UNLESS THE CITY ACCEPTS EARLIER REMOVAL OF INLET PROTECTION IN STREETS. {MAINTENANCE NOTES: }1. 2. 3. 4" MIN 5" MAX \A1;BMP WIDTH VARIES \A1;BMP WIDTH VARIES \A1;BMP WIDTH VARIES \A1;BMP WIDTH VARIES TUBULAR MARKER TUBULAR MARKER IP 1' MIN. 1' MIN. 1' MIN. APPROVED: DATE: DETAIL DRAWN BY: FORT COLLINS CONSTRUCTION STORMWATER DETAILS FORT COLLINS, CO. UTILITIES CITY OF (970) 221-6700 AREA INLET FILTER GRAVEL 01/03/01 D-24 NBJ GENERAL NOTES: SECTION A-A PLAN VIEW 1. INSPECT AND REPAIR FILTER AFTER EACH STORM EVENT. REMOVE SEDIMENT WHEN ONE HALF OF THE FILTER DEPTH HAS BEEN FILLED. REMOVED SEDIMENT SHALL BE DEPOSITED IN AN AREA TRIBUTARY TO A SEDIMENT BASIN OR OTHER FILTERING MEASURES. 2. SEDIMENT AND GRAVEL SHALL BE IMMEDIATELY REMOVED FROM TRAVELED WAY OF ROADS. FILTERED WATER OVERFLOW CONCRETE BLOCK WIRE SCREEN GRAVEL FILTER GRAVEL FILTER AREA INLET WITH GRATE RUNOFF A A (WIRE APPROX. SCREEN 1/2 IN. MESH) CONCRETE BLOCK (APPROX. 3/4 IN. DIA.) GRAVEL FILTER IP 005 C601 CURB INLET PROTECTION NOT TO SCALE 006 C601 AREA INLET FILTER GRAVEL CF RS RS RS RS RS CF CF CF CF CF CF IP IP IP IP IP IP IP IP RS RS No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C600 EROSION CONTROL PLAN A. Reese B. Ruch 1"=30' 19 NORTH ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 1. IT SHOULD BE NOTED THAT ANY EROSION CONTROL PLAN SERVES ONLY AS A GUIDELINE TO THE CONTRACTOR. STAGING AND/OR PHASING OF BEST MANAGEMENT PRACTICES (BMPs) IS EXPECTED. ADDITIONAL AND/OR DIFFERENT BMPs FROM THOSE ORIGINALLY DEPICTED MAY BE NECESSARY DURING CONSTRUCTION DUE TO CHANGING SITE CONDITIONS OR AS REQUIRED BY LOCAL AUTHORITIES. 2. THIS EROSION CONTROL PLAN IS SCHEMATIC IN NATURE. AS SUCH, GRAPHICAL SYMBOLS MAY NOT BE TO SCALE, NOR ARE THEY NECESSARILY SHOWN IN THEIR EXACT LOCATION. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING (CITY, STATE DISCHARGE PERMIT, ETC.) AND COMPLIANCE WITH GOVERNING AUTHORITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR (OR PERMIT HOLDER) TO ENSURE EROSION CONTROL MEASURES ARE PROPERLY MAINTAINED AND FOLLOWED. 4. CONTRACTOR SHALL IMPLEMENT THE APPROPRIATE EROSION CONTROL MEASURES ACCORDING THE THE CONSTRUCTION SEQUENCING AND LEVEL OF SITE STABILIZATION. 5. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR ALL STORM DRAINS, SWALES, PONDS AND RAIN GARDENS UNTIL SITE IS FULLY STABILIZED. 6. CONTRACTOR SHALL IMPLEMENT APPROPRIATE INLET PROTECTION FOR DOWNSPOUT CONNECTIONS, TO THE STORM DRAIN SYSTEM, UNTIL CONNECTION IS ESTABLISHED WITH DOWNSPOUT. 7. INLET PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN WATTLES FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.) 8. CONTRACTOR IS RESPONSIBLE FOR STABILIZING ALL SLOPES, PARTICULARLY THOSE STEEPER THAN 6:1. CRIMP MULCHING, HYDRO MULCHING, EROSION MATS, TEMPORARY IRRIGATION, AND ADDITIONAL WATTLES OR SILT FENCING MAY BE NECESSARY TO ESTABLISH VEGETATIVE COVER AND STABILIZE THE SLOPE. 9. CONTRACTOR IS RESPONSIBLE FOR PREVENTING SEDIMENT FROM UNSTABILIZED LANDSCAPE AREAS FROM MIGRATING ONTO AND ENTERING THE PERMEABLE PAVER SYSTEMS UNTIL UPGRADIENT TRIBUTARY AREAS ARE FULLY STABILIZED. 10. ADDITIONAL WATTLES, SILT FENCE, OR OTHER MEASURES, MAY BE NECESSARY TO ENSURE THAT EACH BUILDING PAD IS STABILIZED THROUGHOUT CONSTRUCTION. WATTLES SHALL BE PROVIDED AROUND BUILDING PAD SIDES TO ENSURE AT NO TIME SHALL SEDIMENT BE ALLOWED TO CROSS THE PUBLIC SIDEWALKS. 11. CONTRACTOR SHALL IMPLEMENT APPROPRIATE PERIMETER PROTECTION FOR AREAS DIRECTING DRAINAGE OFFSITE. PERIMETER PROTECTION SHALL BE ADAPTED, AS NECESSARY, TO THE SURROUNDING SURFACE TYPE AND CONDITION (i.e., STAKE-DRIVEN SEDIMENT CONTROL LOGS OR SILT FENCE FOR BARE SOIL, GRAVEL SOCKS FOR PAVEMENT, ETC.) 12. FUELING FACILITIES SHALL BE LOCATED AT LEAST ONE HUNDRED (100) FEET FROM NATURAL BODY OF WATER, WETLAND, NATURAL DRAINAGE WAY OR MANMADE DRAINAGE WAY. THE FUEL TANKS AND FUELING AREA MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW A FUEL SPILL TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. 13. CONSTRUCTION WASTE STORAGE (DUMPSTERS) AND PORTABLE SANITATION UNITS (CONSTRUCTION TOILETS) SHALL BE LOCATED AT LEAST FIFTY (50) FEET FROM ANY STORMWATER INLET, WETLAND, OR DRAINAGE WAY. SAID FACILITIES MUST BE SET IN A CONTAINMENT AREA THAT WILL NOT ALLOW POLLUTANTS TO DIRECTLY FLOW, SEEP, RUN OFF, OR BE WASHED INTO A BODY OF WATER, WETLAND OR DRAINAGE WAY. DUMPSTERS SHALL BE LOCATED ON FLAT, STABLE GROUND, AND CONSTRUCTION TOILETS SHALL BE STAKED DOWN. 14. THE CONTRACTOR AND ALL SUBCONTRACTORS WILL COOPERATE WITH THE CITY'S CONSTRUCTION INSPECTORS BY CEASING OPERATIONS WHEN WINDS ARE OF SUFFICIENT VELOCITY TO CREATE BLOWING DUST WHICH, IN THE INSPECTOR'S OPINION, IS HAZARDOUS TO THE PUBLIC HEALTH AND WELFARE. 15. WHERE SEASONAL CONSTRAINTS (E.G., DURING SUMMER AND WINTER MONTHS) INHIBIT PERMANENT SEEDING OPERATIONS, DISTURBED AREAS WILL BE TREATED WITH MULCH AND MULCH TACKIFIER OR OTHER MATERIALS APPROVED BY EROSION CONTROL STAFF TO PREVENT EROSION. 16. CONTRACTOR SHALL EXERCISE CAUTION TO PROTECT RAIN GARDENS AND MODIFIED RAIN GARDEN FROM SEDIMENTATION. THIS INCLUDES EDUCATING SUBCONTRACTORS ON-SITE. 17. SEE LANDSCAPE PLANS FOR ADDITIONAL INFORMATION ON PLANTING, REVEGETATION, HARDSCAPE AND OTHER PERMANENT SITE STABILIZATION METHODS. 18. DIRT AND DEBRIS FROM CONSTRUCTION ACTIVITIES TRACKED ON CITY STREETS SHALL BE KEPT TO A MINIMUM AND CLEANED NIGHTLY OR AT THE SUGGESTION OF THE CITY'S EROSION CONTROL INSPECTOR. 19. CONTRACTOR SHALL KEEP CONSTRUCTION VEHICLES ENTERING AND EXITING SITE TO A MINIMUM. EROSION CONTROL NOTES: TABLE OF CONSTRUCTION SEQUENCE AND BMP APPLICATION Project: Drake Redevelopment CONSTRUCTION PHASE MOBILIZATION DEMOLITION GRADING BEST MANAGEMENT PRACTICES (BMPS) Structural "Installation" Flow Barriers (Bales, Wattles, etc.) (RS) UTILITIES INSTALLATION FLAT WORK INSTALLATION VERTICAL INSTALLATION LANDSCAPE DEMOBILIZATION Concrete Washout Area (CWA) * All Temporary BMPs to be Removed once Construction is Complete Vehicle Tracking Pad * (VTC) Construction Fencing * (CF) Inlet Protection * (IP) BENCHMARK NOTE: ALL BMPS SHOWN ON THIS PLAN ARE GRAPHIC REPRESENTATIONS ONLY. FINAL DETERMINATION OF SIZE AND LOCATION SHALL BE DETERMINED BY THE CONTRACTOR AND DOCUMENTED ON THE DYNAMIC SITE PLAN. 1. CONTRACTOR SHALL IMMEDIATELY STABILIZE ALL DISTURBED SLOPES BY CRIMP MULCHING OR SIMILAR METHODS. 2. TOTAL DISTURBED AREA = 7.02 ACRES 3. SWMP ADMINISTRATOR: Contact ________________________________ Company ________________________________ Address ________________________________ Phone________________________________ 4. CONTRACTOR TO PROVIDE VEHICLE TRACKING CONTROL FOR CONCRETE WASHOUT AREA IF ACCESS IS OFF PAVEMENT. 5. REFER TO THE PRELIMINARY DRAINAGE REPORT FOR DRAKE REDEVELOPMENT, DATED JULY 25, 2018, BY NORTHERN ENGINEERING, FOR ADDITIONAL INFORMATION. GENERAL NOTES: LEGEND: 4953 PROPOSED CONTOUR PROPOSED STORM SEWER PROPOSED SWALE EXISTING CONTOUR PROPOSED CURB & GUTTER PROPERTY BOUNDARY PROPOSED INLET VEHICLE TRACKING CONTROL PAD CONSTRUCTION FENCE w/ ROCK SOCK CF CONCRETE WASHOUT ROCK SOCK CWA RS VTC CF INLET PROTECTION IP PROJECT DATUM: NAVD88 CITY OF FORT COLLINS BENCHMARK 21-92 NORTHWEST CORNER OF WEST DRAKE RD. AND RESEARCH BLVD., ON A POWER TOWER BASE. ELEV.= 5042.84 CITY OF FORT COLLINS BENCHMARK 14-97 APPROXIMATELY 100 FEET WEST OF THE INTERSECTION OF CENTRE AVE. AND RESEARCH BLVD.,ON THE WEST END OF THE SOUTH HEADWALL ON CENTRE AVE. ELEV.= 5051.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.17' BASIS OF BEARINGS THE BASIS OF BEARINGS IS THE NORTH LINE OF THE NORTHEAST QUARTER, SECTION 26-7-69, AS BEARING N 89°30' W. ACCESS RAMP DRAKE ROAD (ROW VARIES) EXISTING 18" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER EXISTING WALK EXISTING WALK EXISTING STRIPING EXISTING STRIPING EXISTING 18" VERTICAL CURB & GUTTER EXISTING 18" VERTICAL CURB & GUTTER EXISTING STRIPING LOT 5 6 8 8 8 12 4 4 4 5 J K EXISTING STRIPING EXISTING STRIPING EXISTING STRIPING EXISTING STRIPING L B B A A A A CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C500 STRIPING & SIGNAGE PLAN DRAKE ROAD A. Reese B. Ruch 1"=20' 18 NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO LANDSCAPE PLANS FOR STREET TREE INFORMATION, AND SURVEY DOCUMENTS FOR ADDITIONAL RIGHT-OF-WAY AND EASEMENT INFORMATION. 10 YELLOW ISLAND CROSS HATCHING WHITE ISLAND CROSS HATCHING 4" SOLID YELLOW LINE 4" SOLID WHITE LINE (2) 4" SOLID LINES; 4" APART DOUBLE YELLOW LINE 4" BROKEN YELLOW LINE 8" SOLID WHITE LINE DOUBLE YELLOW LINE 4" SOLID AND 4" BROKEN; 4" APART 9 6 3 5 1 8 2 4 7 STRAIGHT AND RIGHT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING BICYCLIST AND ARROW 18" X 9' CROSSING LINE, SEE NOTES PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING 18" WIDE STOP BAR PREFORMED PLASTIC PAVEMENT MARKING "STOP" (22.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING STRAIGHT AND LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING RIGHT TURN ARROW (15.5 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING LEFT TURN ARROW (15.5 S.F. EA.) RIGHT AND LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING TWO WAY LEFT TURN ARROW (31 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING PREFORMED PLASTIC PAVEMENT MARKING "ONLY" (22.5 S.F. EA.) L H D C B A K E F G I J M LANE REDUCTION ARROW PREFORMED PLASTIC PAVEMENT MARKING 11 MEDIAN LINE YELLOW 18" WIDE 50' O.C. 45° ANGLES 10' 30' 10' 30' 10' 12 4" BROKEN WHITE 10' N "LANE ENDS" PREFORMED PLASTIC PAVEMENT MARKING 4" WHITE DASHED LINE 3' 3' 3' 3' 3' O 18" WIDE WHITE MEDIAN STRIPING PREFORMED PLASTIC PAVEMENT MARKING A. ALL SIGNAGE AND MARKING IS SUBJECT TO THE GENERAL NOTES ON THE COVER SHEET OF THESE PLANS, AS WELL AS THE TRAFFIC SIGNING AND MARKING CONSTRUCTION NOTES LISTED HERE. B. ALL SYMBOLS, INCLUDING ARROWS, ONLYS, CROSSWALKS, STOP BARS, ETC. SHALL BE PRE-FORMED THERMO-PLASTIC. C. ALL SIGNAGE SHALL BE PER CITY OF FORT COLLINS AND THESE PLANS OR AS OTHERWISE SPECIFIED IN MUTCD. D. ALL LANE LINES FOR ASPHALT PAVEMENT SHALL RECEIVE TWO COATS OF LATEX PAINT WITH GLASS BEADS. E. ALL LANE LINES FOR CONCRETE PAVEMENT SHALL BE EPOXY PAINT. F. PRIOR TO PERMANENT INSTALLATION OF TRAFFIC STRIPING AND SYMBOLS, THE DEVELOPER SHALL PLACE TEMPORARY TABS OR TAPE DEPICTING ALIGNMEMT AND PLACEMENT OF THE SAME. THEIR PLACEMENT SHALL BE APPROVED BY THE CITY OF FORT COLLINS ENGINEERS PRIOR TO PERMANENT INSTALLATION OF STRIPING AND SYMBOLS. G. PRE-FORMED THERMO-PLASTIC APPLICATIONS SHALL BE AS SPECIFIED IN THESE PLANS AND/OR THESE STANDARDS. H. EPOXY APPLICATIONS SHALL BE APPLIED AS SPECIFIED IN CDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION. I. ALL SURFACES SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION OF STRIPING OR MARKINGS. J. ALL SIGN POSTS SHALL UTILIZE BREAK-AWAY ASSEMBLIES AND FASTENERS PER THE STANDARDS. K. A FIELD INSPECTION OF LOCATION AND INSTALLATION OF ALL SIGNS SHALL BE PERFORMED BY THE CITY OF FORT COLLINS ENGINEERS. ALL DISCREPANCIES IDENTIFIED DURING THE FIELD INSPECTION MUST BE CORRECTED BEFORE THE 2-YEAR WARRANTY PERIOD WILL BEGIN. L. THE DEVELOPER INSTALLING SIGNS SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES. M. SPECIAL CARE SHALL BE TAKEN IN SIGN LOCATION TO ENSURE AN UNOBSTRUCTED VIEW OF EACH SIGN. N. SIGNAGE AND STRIPING HAS BEEN DETERMINED BY INFORMATION AVAILABLE AT THE TIME OF REVIEW. PRIOR TO INITIATION OF THE WARRANTY PERIOD. THE CITY OF FORT COLLINS RESERVES THE RIGHT TO REQUIRE ADDITIONAL SIGNAGE AND/OR STRIPING IF THE CITY OF FORT COLLINS DETERMINES THAT AN UNFORESEEN CONDITION WARRANTS SUCH SIGNAGE ACCORDING TO THE MUTCD OR THE CDOT M AND S STANDARDS. ALL SIGNAGE AND STRIPING SHALL FALL UNDER THE REQUIREMENTS OF THE 2-YEAR WARRANTY PERIOD FOR NEW CONSTRUCTION (EXCEPT FAIR WEAR ON TRAFFIC MARKINGS). O. SLEEVES FOR SIGN POSTS SHALL BE REQUIRED FOR USE IN ISLANDS/MEDIANS. REFER TO CHAPTER 14, TRAFFIC CONTROL DEVICES, FOR ADDITIONAL DETAIL. P. STREET NAME SIGNS AT INTERSECTIONS SHALL BE INSTALLED ABOVE STOP SIGNS ON SAME POLE. STRIPING LEGEND: STRIPING NOTES: 8" WHITE DASHED LINE 3' 3' 3' 3' 3' (NOTE: ALL ITEMS MAY NOT APPLY TO THIS PLAN) PAVEMENT STRIPING PAVEMENT MARKINGS STRAIGHT ARROW (15 S.F. EA.) PREFORMED PLASTIC PAVEMENT MARKING 30' 10' 30' 10' LEGEND: PROPOSED VERTICAL CURB & GUTTER EASEMENTS PROPERTY BOUNDARY PROPOSED LOT LINE PROPOSED ROW SEE THIS SHEET BELOW LEFT SEE THIS SHEET ABOVE RIGHT 27.65 27.70 28.68 28.95 28.86 28.31 28.30 28.27 28.27 26.48 26.19 26.47 26.48 26.52 26.56 26.27 25.93 25.92 25.91 25.77 25.60 25.64 25.88 26.23 26.65 27.25 28.07 28.21 28.41 28.71 28.55 27.93 27.62 27.92 27.93 27.64 28.07 27.84 28.24 27.96 27.86 28.13 27.85 27.68 28.77 27.35 26.99 26.38 27.47 26.44 PROPOSED 4' CONCRETE PAN PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) 27.84 27.64 30.12 30.10 29.95 29.90 29.88 29.92 29.98 29.95 29.96 30.02 29.14 29.24 28.45 28.73 28.64 30.07 29.48 29.09 30.07 29.54 30.07 30.07 28.60 29.43 29.47 29.45 29.40 29.37 29.41 29.40 29.36 28.67 28.65 28.66 28.71 28.74 28.70 28.70 28.80 28.60 2' CONCRETE CHASE 2' CONCRETE CHASE 2' CONCRETE CHASE 26.23 26.54 26.72 26.34 25.91 28.55 2.0% 2.0% 2.0% 2.0% 2.0% 28.27 30.07 30.07 30.19 30.07 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C408 GRADING PLAN A. Reese B. Ruch 1"=10' 17 KEYMAP NTS BUS PAD CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB SEE SHEET C405 SEE SHEET C407 C401 C402 C403 C404 C405 C406 C407 C408 31.17 31.09 31.07 32.67 32.63 32.82 32.94 30.57 30.60 30.84 30.97 29.87 29.78 29.72 29.68 29.62 29.54 29.38 30.67 30.51 33.00 33.00 32.72 30.05 32.29 32.18 32.37 32.40 32.57 32.67 32.91 32.91 32.68 32.67 32.67 32.91 32.66 32.66 32.64 32.67 32.99 32.52 33.00 33.00 33.00 33.00 33.00 33.00 33.00 33.00 31.66 32.07 31.56 30.94 30.85 30.20 30.25 30.06 29.26 27.99 28.19 28.08 28.05 31.87 31.88 31.89 32.75 32.69 32.05 32.05 32.33 33.00 32.87 32.88 32.33 33.00 33.00 31.41 32.87 31.37 31.61 32.88 32.88 32.86 32.98 33.00 30.96 (30.23) 30.75 32.69 32.88 32.88 33.00 PROPOSED PROPOSED STAIRS STAIRS PROPOSED STAIRS 32.33 32.88 33.00 32.33 33.00 31.30 32.88 32.88 32.88 32.88 33.00 33.00 32.88 33.00 33.00 33.00 33.00 33.00 30.28 30.25 32.08 32.04 31.99 31.96 31.56 31.52 31.48 31.46 30.85 30.82 30.79 30.78 30.17 30.15 30.12 30.10 33.00 33.00 32.91 32.91 30.06 31.91 31.94 31.94 31.91 31.26 31.23 31.22 31.24 30.73 30.79 30.80 30.76 29.95 29.90 29.88 29.92 29.98 29.95 29.96 30.02 30.83 30.86 30.85 30.79 31.38 31.35 31.36 31.42 32.05 32.08 32.07 32.01 30.63 30.53 29.14 29.24 0.6% 2.0% 2.0% PROPOSED FLUSH CURB No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C407 GRADING PLAN A. Reese B. Ruch 1"=10' 16 KEYMAP NTS BUS PAD CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET C408 LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB SEE SHEET C404 C401 C402 C403 C404 C405 C406 C407 C408 27.00 26.08 26.12 26.15 26.18 27.42 26.80 26.92 26.91 26.77 27.26 27.22 27.26 25.65 25.60 25.61 25.56 25.63 25.67 25.71 25.82 26.12 25.93 25.89 25.93 26.85 26.61 26.46 26.51 26.75 26.87 26.61 26.57 25.79 25.46 25.28 24.67 24.72 24.52 23.25 22.75 22.59 22.49 22.73 22.88 27.00 27.00 27.00 27.00 27.00 26.76 27.00 27.00 26.13 26.11 26.10 26.37 24.47 24.44 (24.66) (23.65) 26.62 27.44 PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN 27.00 26.90 26.90 26.87 26.13 26.09 26.19 27.00 27.00 26.90 26.80 25.80 25.01 26.80 26.76 27.00 26.87 26.87 26.73 27.00 26.73 26.84 27.00 26.84 26.94 24.06 23.82 22.37 22.31 26.72 25.69 26.05 26.37 26.07 25.78 26.56 24.53 24.29 26.11 26.53 2.0% 2.0% 1.2% 1.3% 1.3% 0.5% 0.8% 2.0% 2.0% PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) 25.99 26.41 25.47 2.0% 2.0% 24.92 24.92 25.88 26.11 BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) 27.02 27.14 27.48 27.55 27.65 25.89 25.28 23.70 27.46 27.36 2.0% No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C406 GRADING PLAN A. Reese B. Ruch 1"=10' 15 KEYMAP NTS BUS PAD CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB SEE SHEET C403 SEE SHEET C405 C401 C402 C403 C404 C405 C406 C407 C408 28.53 28.20 28.19 28.14 28.60 28.76 28.54 28.43 28.69 28.49 28.41 29.05 28.99 28.95 28.34 27.60 27.76 27.15 27.03 26.74 26.89 27.44 27.65 27.57 27.42 27.41 27.55 27.56 27.51 27.36 27.30 27.53 27.63 27.55 27.45 26.60 26.76 26.47 26.52 26.07 26.04 25.99 25.90 26.05 26.25 26.11 26.07 28.21 28.05 27.83 27.91 27.67 27.56 27.19 27.61 27.62 28.19 28.54 27.73 27.68 27.77 28.10 27.56 27.55 26.80 27.32 27.44 27.55 27.05 27.60 27.31 27.32 27.76 27.47 27.03 27.73 27.78 26.36 26.25 26.21 26.17 26.61 26.58 27.58 27.25 27.70 27.45 27.38 28.81 27.48 27.15 26.73 27.26 26.12 25.93 28.02 27.65 27.70 28.07 28.21 28.47 PROPOSED 18" VERTICAL (TYP.) CURB & GUTTER PROPOSED 4' CONCRETE PAN PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) 28.47 26.21 28.79 28.77 28.77 28.75 28.73 28.73 28.75 28.47 28.47 28.47 28.39 28.53 28.57 28.54 28.26 28.25 28.24 28.24 28.43 28.13 28.12 28.10 28.11 28.41 27.87 27.44 27.00 28.06 27.99 27.38 27.84 28.22 27.32 27.64 2.0% 2.0% 2.0% 2.1% 2.0% 2.0% 2.0% 2.0% 2.0% 27.76 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C405 GRADING PLAN A. Reese B. Ruch 1"=10' 14 KEYMAP NTS BUS PAD SEE SHEET C408 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET C406 LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB SEE SHEET C402 SEE SHEET C404 C401 C402 C403 C404 C405 C406 C407 C408 33.00 33.00 32.88 31.67 31.68 32.88 32.88 33.00 32.33 32.33 32.10 31.59 30.98 30.65 30.82 30.60 31.27 31.35 31.65 30.92 31.90 31.95 31.33 31.17 30.83 30.66 30.83 31.50 31.57 32.82 32.88 32.96 32.70 31.82 31.81 32.80 32.10 32.01 31.29 32.74 31.47 32.98 33.00 33.00 33.00 33.00 32.74 32.88 32.50 32.35 32.88 32.55 32.55 32.55 32.88 33.00 33.00 32.88 32.88 32.56 32.56 32.50 32.53 32.45 33.00 32.32 32.30 33.00 28.91 28.83 28.37 28.83 29.86 30.78 30.71 30.71 30.72 31.70 31.72 31.72 31.65 29.32 29.05 29.19 29.95 30.62 29.91 30.53 30.81 30.68 28.43 28.20 28.10 28.78 28.75 29.34 30.09 29.07 30.06 31.08 33.00 28.47 PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 4' CONCRETE PAN PROPOSED 4' PROPOSED 4' CONCRETE PAN CONCRETE PAN PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) 28.47 33.00 33.00 32.88 31.45 31.17 32.33 33.00 33.00 32.33 31.62 31.39 32.88 31.70 31.46 31.26 32.90 33.00 31.27 31.87 31.88 31.89 31.28 31.28 32.17 32.20 33.00 33.00 33.00 33.00 33.00 33.00 31.67 31.63 31.55 31.53 29.92 29.92 29.90 28.79 28.77 28.77 28.75 28.73 28.73 28.75 29.87 29.89 29.89 29.88 30.70 30.68 30.68 30.70 31.69 31.70 31.71 31.69 32.33 31.54 32.75 32.69 30.94 30.90 30.83 30.80 29.92 29.89 29.84 29.81 28.47 32.05 31.37 31.61 32.86 32.98 2.0% 2.0% 0.6% 1.9% PROPOSED FLUSH CURB 31.20 BOULDER WALL (RE: LANDSCAPE) 31.40 32.83 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C404 GRADING PLAN A. Reese B. Ruch 1"=10' 13 KEYMAP NTS BUS PAD SEE SHEET C407 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET C405 LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB SEE SHEET C401 C401 C402 C403 C404 C405 C406 C407 C408 27.00 27.00 27.00 26.67 26.43 26.43 26.44 26.55 26.74 26.42 26.34 26.29 26.37 25.84 25.86 26.14 26.20 26.50 26.27 26.15 26.08 26.03 25.95 25.98 26.14 26.19 26.97 26.95 26.75 26.63 26.75 26.75 26.88 24.32 26.56 24.56 22.00 25.17 25.28 25.40 27.00 25.17 27.00 27.00 27.00 PROPOSED 4' CONCRETE PAN 24.77 24.52 23.77 23.70 23.82 23.41 23.53 22.29 22.41 22.24 26.68 26.87 26.90 26.95 27.00 27.00 27.00 25.53 26.34 26.34 25.58 26.82 26.34 27.00 26.34 26.84 27.00 26.92 26.85 27.00 26.58 26.52 26.49 26.45 26.44 26.96 26.95 26.97 27.00 26.97 27.00 27.00 26.88 26.08 26.90 27.00 27.00 26.90 26.90 26.14 26.31 26.94 24.32 24.07 24.32 24.76 26.91 27.00 0.8% 0.8% 0.7% 2.0% 2.0% PROPOSED FLUSH CURB PROPOSED FLUSH CURB BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) 23.98 24.22 24.56 25.33 25.33 25.33 23.33 25.33 25.33 24.54 22.76 23.05 23.12 22.19 22.30 21.89 21.75 21.62 21.56 21.58 24.92 24.92 27.00 26.13 25.88 26.44 26.11 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C403 GRADING PLAN A. Reese B. Ruch 1"=10' 12 KEYMAP NTS BUS PAD SEE SHEET C406 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB SEE SHEET C402 C401 C402 C403 C404 C405 C406 C407 C408 26.34 26.50 26.60 28.50 27.93 27.74 27.55 27.65 27.33 27.42 27.13 27.16 26.69 26.50 26.29 26.28 26.29 26.33 25.81 25.78 25.88 26.04 25.90 26.06 25.82 25.83 26.23 26.25 26.41 26.41 26.62 26.64 26.85 27.05 26.84 27.02 27.35 28.16 28.04 28.19 28.09 27.89 27.86 28.52 27.93 28.74 28.69 30.18 28.98 28.31 28.02 30.16 29.96 30.18 30.16 29.96 25.82 29.96 30.19 30.16 26.43 25.95 26.19 28.20 28.19 28.14 26.98 28.26 30.19 30.18 30.16 30.16 LOT 4 2' CONCRETE CHASE 30.18 30.18 28.47 PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 18" VERTICAL (TYP.) CURB & GUTTER PROPOSED 4' CONCRETE PAN PROPOSED FLUSH CURB PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN 29.96 26.96 25.29 25.16 25.27 30.16 30.06 30.16 29.96 25.62 26.47 26.67 28.45 27.95 24.90 24.78 24.76 24.64 24.56 24.68 27.00 27.69 27.28 27.10 27.52 26.91 27.46 28.47 26.61 26.99 26.60 26.05 26.21 25.98 28.47 28.47 28.22 0.7% 0.8% 2.0% 2.0% 0.6% 2.0% 2.0% 2.0% 2.0% 4.1% BOULDER WALL (RE: LANDSCAPE) 26.96 28.06 28.46 29.96 30.16 27.94 27.83 26.41 26.53 26.85 29.36 28.74 26.13 26.21 26.92 25.72 BOULDER WALL (RE: LANDSCAPE) No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C402 GRADING PLAN A. Reese B. Ruch 1"=10' 11 KEYMAP NTS BUS PAD SEE SHEET C405 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB SEE SHEET C403 SEE SHEET C401 C401 C402 C403 C404 C405 C406 C407 C408 30.56 30.44 30.43 30.67 30.30 30.26 30.32 29.88 29.53 29.36 29.41 29.69 28.67 28.44 28.31 28.46 28.80 30.12 29.81 29.83 30.43 30.64 30.64 30.32 30.27 30.30 30.34 33.00 33.00 31.26 32.20 33.00 31.78 31.63 31.05 30.91 30.00 29.89 28.99 30.19 33.00 30.94 30.95 30.95 30.95 30.93 30.93 30.93 30.96 30.95 30.16 30.19 30.18 30.18 LOT 4 2.0% 30.93 30.93 30.73 30.69 30.95 30.95 30.18 30.18 30.18 30.18 30.18 29.48 29.01 30.50 30.58 30.67 31.08 33.00 28.47 27.50 26.37 28.06 PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN 30.87 28.47 2.0% 1.3% 1.5% 0.6% 2.0% 2.0% 2.0% BOULDER WALL (RE: LANDSCAPE) 30.49 29.74 29.34 30.90 30.66 29.62 30.00 30.83 BOULDER WALL (RE: LANDSCAPE) 31.20 BOULDER WALL (RE: LANDSCAPE) 31.40 32.83 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 10 0 10 Feet 10 20 30 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C401 GRADING PLAN A. Reese B. Ruch 1"=10' 10 KEYMAP NTS BUS PAD SEE SHEET C404 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R SEE SHEET C402 LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB C401 C402 C403 C404 C405 C406 C407 C408 LOT 2 LOT 1 TRACT A LOT 4 PROPOSED INLET BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C400 OVERALL GRADING PLAN A. Reese B. Ruch 1"=30' 9 KEYMAP NTS BUS PAD CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R LEGEND: 5013 PROPOSED CONTOUR EXISTING CONTOUR PROPERTY BOUNDARY PROPOSED SPOT ELEVATION 33.43 PROPOSED SLOPES 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 3. ALL CURB SPOTS SHOWN ARE FLOWLINE ELEVATIONS. ALL OTHER SPOTS ARE FINISHED GRADE ELEVATIONS. 4. ALL PROJECT DATA IS ON THE CITY OF FORT COLLINS VERTICAL DATUM NAVD88. SEE COVER SHEET FOR BENCHMARK REFERENCES. 5. CONTRACTOR SHALL CONFIRM AND COORDINATE WITH THE STAMPED ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR CONTAINER FOUNDATIONS AND ASSOCIATED THRESHOLDS. 6. PLEASE REFER TO THE EROSION CONTROL PLAN SHEETS AND REPORT FOR TEMPORARY CONTROL MEASURES AND CONSTRUCTION SEQUENCING THAT SHALL BE USED TO PREVENT LOADING OF THE DRAINAGE FACILITIES WITH SEDIMENT DURING CONSTRUCTION. NOTES: 2.0% (47.45) EXISTING SPOT ELEVATION PROPOSED STORM PROPOSED VERTICAL CURB AND GUTTER PROPOSED SUBGRADE SPOT ELEVATION 33.43 SUB C401 C402 C403 C404 C405 C406 C407 C408 COLLEGE AVENUE (ROW VARIES) ENCHANTE ENTERPRISES LLC 2631 S COLLEGE AVE PLUTUS HOLDINGS LLC 2633 S COLLEGE AV. DRAKE ROAD (ROW VARIES) EXMH 2 INV. IN=5014.50 (S) INV. IN=5014.83 (W) INV. OUT=5014.44 (N) FG=5023.41 EXMH 1 INV. IN=5012.69 (S) INV. IN=5012.15 (W) INV. OUT=5011.99 (E) FG=5022.24 BLDG F SERV INV. OUT=5014.95 (E) FG=5026.88 SERVICE CONNECTION E INV. IN=5013.39 (S) INV. IN=5013.56 (W) INV. OUT=5013.39 (N) FG=5023.22 BLDG E SERV INV. OUT=5013.73 (E) FG=5026.76 17.68 LF 6" PVC @ 1.00% 11.80 LF 6" PVC @ 1.00% EXISTING 18" CLAY SANITARY EXISTING 18" RCP STORM DRAIN EXISTING 15" RCP STORM DRAIN EXISTING 15" RCP STORM DRAIN EXISTING 15" RCP STORM DRAIN EXISTING 12" WATER EXISTING 12" WATER EXISTING 24" WATER EXISTING EXISTING 8" WATER 16" WATER EXISTING 8" WATER EXISTING 10" CLAY SANITARY EXISTING 10" CLAY SANITARY 174.61 LF 12" PVC N90°00'00"E 77.70 LF 12" PVC 12"x6" SWIVEL TEE N90°00'00"E w/ 6" GV (N) N:118106.01 E:194568.68 PROPOSED INLET CONNECT TO EXISTING STORM DRAIN PROPOSED STORM DRAIN CONNECT TO EXISTING STORM DRAIN PROPOSED INLET PROPOSED WATER QUALITY CHAMBERS PROPOSED INLET PROPOSED INLET PROPOSED TRANSFORMER PROPOSED FH PROPOSED 1.5" WATER SERVICE CONNECT TO EXISTING 90° BEND w/ TB & 12" GV (W) N:118106.01 E:194646.38 15' UTILITY EASEMENT UTILITY EASEMENT (WIDTH VARIES) UTILITY EASEMENT (WIDTH VARIES) 6' UTILITY & ACCESS EASEMENT 6' UTILITY & ACCESS EASEMENT 14.48 LF 12" PVC S00°47'36"W CONNECT TO EXISTING 12" WATER N:118419.88 E:194647.06 PROPOSED FH 12"x6" REDUCER w/ 6" GV (S) & FH ASSEMBLY N:118404.91 E:194646.84 26' EMERGENCY ACCESS EASEMENT 24' EMERGENCY ACCESS EASEMENT 24' EMERGENCY ACCESS EASEMENT PROPOSED 1.5" WATER METER No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C303 UTILITY PLAN A. Reese B. Ruch 1"=20' 8 KEYMAP NTS BUS PAD SEE SHEET C302 SEE SHEET C301 C301 C302 C303 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 9. REFER TO PLUMBING PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS, BOTH THE PLUMBING ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 10. ALL SANITARY SEWER SERVICE CONNECTION INVERTS AND LOCATIONS BASED ON BEST AVAILABLE DATA. CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 11. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 12. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443/C877 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). STORM DRAINS SHOWN ON THIS DRAWING AS POLYVINYL CHLORIDE (PVC) SHALL BE SDR 35 OR APPROVED EQUAL. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 14. CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, FIBER, GAS, AND ELECTRIC LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY PROVIDERS. 15. CONTRACTOR TO COORDINATE FINAL LOCATION OF ALL GAS AND ELECTRIC METERS WITH ARCHITECT AND UTILITY PROVIDERS. EXISTING WATER MAIN LEGEND: W G T CTV EXISTING STORM SEWER EXISTING CABLE EXISTING TELEPHONE EXISTING GAS PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED WATER SERVICE EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROPERTY BOUNDARY EXISTING LOTLINE W PROPOSED WATER MAIN PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED ELECTRIC E PROPOSED FIRE SERVICE F EXISTING ELECTRIC E PROPOSED LOTLINE @ 1.00% EXISTING 8" CLAY SANITARY EXISTING 8" SANITARY EXISTING 6" WATER 27.29 LF 12" PVC S33°45'00"E 15.00 LF 12" PVC N56°15'00"E 38.17 LF 12" PVC N78°45'00"E 11.25° & 22.5° BENDS w/ TB N:118112.93 E:194329.00 22.50° BEND w/ TB N:118098.57 E:194356.63 11.25° BEND w/ TB N:118106.01 E:194394.07 11.70 LF 6" PVC S56°15'00"W 17.13 LF 6" PVC S78°45'00"W 215.92 LF 6" PVC N90°00'00"W 15.50 LF 6" PVC S00°00'00"W 20.78 LF 8" PVC S33°45'00"E 3.41 LF 8" PVC S33°45'00"E 24.52 LF 8" PVC S22°30'00"E 145.50 LF 8" PVC S00°00'00"E 5 8 . 9 0 L F 8 " P V C R = 3 0 0 . 0 0 ' 22.50° BEND w/ TB N:117995.60 E:194394.71 22.50° BEND w/ TB N:118083.73 E:194334.43 11.25° BEND w/ TB N:118080.39 E:194317.64 90.00° BEND w/ TB & 6" GV (S) N:118080.39 E:194101.72 PROPOSED INLET PROPOSED INLET PROPOSED STORM DRAIN PROPOSED INLET 8"x6" SWIVEL TEE w/ 6" GV (E) N:118072.96 E:194355.70 12"x12" CROSS w/ 2-12" GV (N,E), 1-6" GV (W), 12"x8" REDUCER (S), & 12"x6" REDUCER (W) N:118090.23 E:194344.16 PROPOSED FH BEGIN HORZ. DEFL. N:118070.12 E:194357.60 END HORZ. DEFL. N:118018.25 E:194385.32 TRACT A PROPOSED TRANSFORMER APPROXIMATE LOCATION EXISTING FH CONNECT TO EXISTING CUT IN 8"x6" TEE w/ TB 1-8:" GV (N) & 1- 6" GV (E) N:117850.11 E:194394.71 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT CONNECT TO EXISTING 4"x6" TAPPING SADDLE w/ TB & 4" GV (N) N:117853.08 E:194064.51 CONNECT TO EXISTING MANHOLE PROPOSED FH PROPOSED 1.5" WATER METER PROPOSED 1.5" WATER SERVICE PROPOSED 4" FIRE SERVICE 55.95 LF 4" PVC S00°33'03"W PROPOSED STORM DRAIN 24' EMERGENCY ACCESS EASEMENT 24' EMERGENCY ACCESS EASEMENT 24' FL-FL 24' FL-FL 24' FL-FL 24' EMERGENCY ACCESS EASEMENT No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C302 UTILITY PLAN A. Reese B. Ruch 1"=20' 7 KEYMAP NTS BUS PAD SEE SHEET C302 SEE SHEET C303 C301 C302 C303 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 9. REFER TO PLUMBING PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS, BOTH THE PLUMBING ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 10. ALL SANITARY SEWER SERVICE CONNECTION INVERTS AND LOCATIONS BASED ON BEST AVAILABLE DATA. CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 11. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 12. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443/C877 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). STORM DRAINS SHOWN ON THIS DRAWING AS POLYVINYL CHLORIDE (PVC) SHALL BE SDR 35 OR APPROVED EQUAL. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 14. CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, FIBER, GAS, AND ELECTRIC LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY PROVIDERS. 15. CONTRACTOR TO COORDINATE FINAL LOCATION OF ALL GAS AND ELECTRIC METERS WITH ARCHITECT AND UTILITY PROVIDERS. EXISTING WATER MAIN LEGEND: W G T CTV EXISTING STORM SEWER EXISTING CABLE EXISTING TELEPHONE EXISTING GAS PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED WATER SERVICE EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROPERTY BOUNDARY EXISTING LOTLINE W PROPOSED WATER MAIN PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED ELECTRIC E PROPOSED FIRE SERVICE F EXISTING ELECTRIC E PROPOSED LOTLINE DRAKE ROAD (ROW VARIES) McCLELLAND DRIVE (37' ROW) SSMH A4 INV. IN=5017.90 (S) INV. OUT=5017.74 (E) FG=5029.83 SSMH A1 INV. IN=5016.38 (W) INV. OUT=5016.19 (N) FG=5026.97 EXMH A INV. IN=5014.50 (W) INV. IN=5015.33 (S) INV. IN=5015.21 (NW) INV. OUT=5014.39 (E) FG=5024.85 BLDG B SERV INV. OUT=5018.26 (N) FG=5033.00 BLDG C SERV INV. OUT=5018.20 (S) FG=5030.84 SERVICE CONNECTION A3 INV. IN=5017.53 (W) INV. IN=5017.70 (N) INV. OUT=5017.53 (E) FG=5029.35 BLDG D SERV INV. OUT=5017.59 (S) FG=5030.03 SERVICE CONNECTION A2 INV. IN=5016.92 (W) INV. IN=5017.08 (N) INV. OUT=5016.92 (E) FG=5027.93 170.61 LF 8" PVC @ 0.50% 122.55 LF 8" PVC @ 0.50% 106.32 LF 8" PVC @ 0.50% 41.56 LF 8" PVC @ 0.50% 35.92 LF 6" PVC @ 1.00% 51.15 LF 6" PVC @ 1.00% 50.68 LF 6" PVC @ 1.00% EXISTING 8" CLAY SANITARY EXISTING 24" WATER EXISTING 18" CLAY SANITARY 139.46 LF 12" PVC S00°00'24"E 14.83 LF 12" PVC S00°03'44"W 180.47 LF 12" PVC S00°00'00"E 12"x8" CROSS w/ 2-12" GV (N,S), 1-8" GV (W), & 8"x6" REDUCER (E) N:118293.39 E:194329.00 246.81 LF 8" PVC N90°00'00"W 28.56 LF 8" PVC N90°00'00"W 3.98 LF 6" PVC N90°00'00"W 12.50 LF 6" PVC N00°00'01"E 90.00° BEND w/ TB & 6" GV (N) N:118293.39 E:194049.65 16.47 LF 6" PVC N90°00'00"E 48.69 LF 6" PVC S67°30'00"E 22.50° BEND w/ TB N:118293.39 E:194345.47 PROPOSED INLET PROPOSED WATER QUALITY CHAMBERS PROPOSED INLET PROPOSED FH 8"x6" REDUCER N:118293.39 E:194053.63 PROPOSED 1.5" WATER METER PROPOSED 1.5" WATER METER PROPOSED 1.5" WATER SERVICE PROPOSED 1.5" WATER SERVICE PROPOSED 1.5" WATER METER PROPOSED 1.5" WATER SERVICE PROPOSED 4" FIRE SERVICE 8"x4" TEE w/ TB & 4" GV (S) N:118293.39 E:194082.19 PROPOSED TRANSFORMER PROPOSED TRANSFORMER PROPOSED FH 12"x6" SWIVEL TEE w/ 6" GV (E) N:118308.22 E:194329.01 22.50° BEND w/ TB N:118274.76 E:194390.45 6.47 LF 6" PVC S90°00'00"E 5.00 LF 6" PVC N90°00'00"E PROPOSED 4" WATER SERVICE PROPOSED 6" FIRE SERVICE PROPOSED 4" WATER METER 8"x8" TEE w/ TB N:118274.76 E:194396.92 90° BEND w/ TB & 6" GV (N) N:118274.76 E:194401.92 PROPOSED TRANSFORMER CONNECT TO EXISTING 12"x24" TAPPING SADDLE w/ TB & 12" GV (S) N:118447.69 E:194329.00 TRACT A 9' UTILITY EASEMENT 15' UTILITY EASEMENT 15' UTILITY EASEMENT 9' UTILITY EASEMENT 40.02 LF 6" PVC S00°00'00"E 41.92 LF 4" PVC S00°00'00"E CONNECT TO EXISTING MANHOLE PROPOSED STORM DRAIN 26' EMERGENCY ACCESS EASEMENT 24' FL-FL 26' EMERGENCY ACCESS EASEMENT 24' FL-FL LOT 4 PROPOSED 2' CONCRETE CHASE No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 20 0 20 Feet 20 40 60 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C301 UTILITY PLAN A. Reese B. Ruch 1"=20' 6 KEYMAP NTS BUS PAD SEE SHEET C302 SEE SHEET C303 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R C301 C302 C303 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 9. REFER TO PLUMBING PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS, BOTH THE PLUMBING ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 10. ALL SANITARY SEWER SERVICE CONNECTION INVERTS AND LOCATIONS BASED ON BEST AVAILABLE DATA. CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 11. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 12. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443/C877 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). STORM DRAINS SHOWN ON THIS DRAWING AS POLYVINYL CHLORIDE (PVC) SHALL BE SDR 35 OR APPROVED EQUAL. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 14. CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, FIBER, GAS, AND ELECTRIC LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY PROVIDERS. 15. CONTRACTOR TO COORDINATE FINAL LOCATION OF ALL GAS AND ELECTRIC METERS WITH ARCHITECT AND UTILITY PROVIDERS. EXISTING WATER MAIN LEGEND: W G T CTV EXISTING STORM SEWER EXISTING CABLE EXISTING TELEPHONE EXISTING GAS PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED WATER SERVICE EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROPERTY BOUNDARY EXISTING LOTLINE W PROPOSED WATER MAIN PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED ELECTRIC E PROPOSED FIRE SERVICE F EXISTING ELECTRIC E PROPOSED LOTLINE SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS LID T OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE X S ELEC H2O S S MH C S S S WV S VAULT ELEC VAULT ELEC S ELEC WV WV H2O WV WV H Y D C S C S C S W W W W W W W W W W W W W W W W W W W W W W W W D D D D W D H Y D ST ST D TF TF TF TF TF W S S S W W W W W W W S S S W F F W W F W DRAKE ROAD (ROW VARIES) McCLELLAND DRIVE (37' ROW) COLLEGE AVENUE (ROW VARIES) THUNDERBIRD DRIVE (60' ROW) 6' SIDEWALK 6' SIDEWALK 12' SIDEWALK 12' SIDEWALK 12' SIDEWALK 5' SIDEWALK 12' SIDEWALK 12' SIDEWALK 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 15' UTILITY EASEMENT 15' UTILITY EASEMENT UTILITY EASEMENT (WIDTH VARIES) 6' UTILITY & ACCESS EASEMENT EXISTING 8" CLAY SANITARY EXISTING 8" SANITARY EXISTING 18" CLAY SANITARY EXISTING 6" WATER EXISTING 15" RCP STORM DRAIN EXISTING 12" WATER EXISTING 8" CLAY SANITARY EXISTING 12" WATER EXISTING 24" WATER EXISTING 24" WATER EXISTING 18" CLAY SANITARY EXISTING EXISTING 8" WATER 16" WATER EXISTING 8" WATER PROPOSED INLET PROPOSED STORM DRAIN PROPOSED FH PROPOSED FH PROPOSED FH APPROXIMATE LOCATION EXISTING FH CONNECT TO EXISTING MANHOLE PROPOSED FH PROPOSED FH LOT 3 LOT 5 LOT 6 LOT 2 LOT 1 TRACT A TRACT A CONNECT TO EXISTING 12" WATER CONNECT TO EXISTING 24" WATER CONNECT TO EXISTING MANHOLE PROPOSED 12" PVC WATER PROPOSED 12" PVC WATER PROPOSED 12" PVC WATER CONNECT TO EXISTING 12" WATER PROPOSED 8" PVC WATER PROPOSED 6" PVC WATER CONNECT TO EXISTING 6" WATER PROPOSED 1.5" WATER SERVICE PROPOSED 1.5" WATER SERVICE PROPOSED 1.5" WATER SERVICE PROPOSED 4" FIRE SERVICE PROPOSED 4" WATER SERVICE PROPOSED 6" FIRE SERVICE PROPOSED 1.5" WATER SERVICE PROPOSED 1.5" WATER SERVICE PROPOSED 4" FIRE SERVICE PROPOSED 6" SANITARY SERVICE PROPOSED 6" SANITARY SERVICE PROPOSED 6" SANITARY SERVICE PROPOSED 6" SANITARY SERVICE PROPOSED INLET CONNECT TO EXISTING STORM DRAIN CONNECT TO EXISTING STORM DRAIN PROPOSED INLET PROPOSED WATER QUALITY CHAMBERS PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED INLET PROPOSED STORM DRAIN PROPOSED 8" PVC WATER PROPOSED 6" PVC WATER PROPOSED 6" SANITARY SERVICE CONNECT TO EXISTING 10" SANITARY PROPOSED 6" SANITARY SERVICE CONNECT TO EXISTING MANHOLE PROPOSED 8" PVC SANITARY PROPOSED 8" PVC SANITARY EXISTING FH PROPOSED INLET ENCHANTE ENTERPRISES LLC 2631 S COLLEGE AVE PLUTUS HOLDINGS LLC 2633 S COLLEGE AV. PROPOSED 2' CONCRETE CHASE LOT 4 TRACT B KEYMAP NTS BUS PAD No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C300 OVERALL UTILITY PLAN A. Reese B. Ruch 1"=30' CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU 5 DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R C301 C302 C303 NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. ALL WATER AND SEWER CONSTRUCTION SHALL BE PER THE CITY OF FORT COLLINS STANDARD CONSTRUCTION SPECIFICATIONS LATEST EDITION. 3. ALL WATER FITTINGS AND VALVES ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 4. UTILITY SERVICES ARE SHOWN IN A SCHEMATIC FASHION ONLY. EXACT LOCATIONS SHALL BE PER THE REQUIREMENTS OF THE RESPECTIVE UTILITY PROVIDERS, AND ARE SUBJECT TO CHANGE IN THE FIELD. 5. MAINTAIN 10' HORIZONTAL AND 18" VERTICAL MINIMUM SEPARATION BETWEEN ALL SANITARY SEWER MAINS, WATER MAINS, AND SERVICES. 6. REFER TO THE PLAT FOR LOT AREAS, TRACT SIZES, EASEMENTS, LOT DIMENSIONS, UTILITY EASEMENTS, OTHER EASEMENTS, AND OTHER SURVEY INFORMATION. 7. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 8. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OR FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 9. REFER TO PLUMBING PLANS FOR ALL WATER SERVICE AND SANITARY SEWER SERVICE LOCATIONS. IF CONFLICT OCCURS, BOTH THE PLUMBING ENGINEER AND CIVIL ENGINEER SHALL BE CONTACTED PRIOR TO INSTALLATION OR ORDERING OF MATERIALS. 10. ALL SANITARY SEWER SERVICE CONNECTION INVERTS AND LOCATIONS BASED ON BEST AVAILABLE DATA. CONTRACTOR TO VERIFY LOCATION PRIOR TO CONSTRUCTION AND NOTIFY ENGINEER OF ANY DISCREPANCIES. 11. PIPE LENGTHS ARE CALCULATED FROM THE CENTER OF MANHOLES AND INLET BOX STRUCTURES. SPECIFIED LENGTH OF PIPE INCLUDES THE LAYING LENGTH OF FLARED END SECTIONS. 12. ALL RCP SHALL BE CLASS III OR GREATER. PIPE MATERIAL, BEDDING, AND INSTALLATION WITHIN PUBLIC RIGHTS-OF-WAY SHALL BE GOVERNED BY THE CITY OF FORT COLLINS. ALTERNATES (SUCH AS ADS N-12 OR HP SANITITE) OUTSIDE OF THE R.O.W. SHALL BE APPROVED IN ADVANCE BY THE ENGINEER. ALL JOINTS SHALL BE 'WATERTIGHT' USING APPROPRIATE GASKETS OR JOINT WRAPS (PER ASTM C443/C877 FOR RCP AND PER ASTM F477 / D3212 FOR PLASTIC PIPE). STORM DRAINS SHOWN ON THIS DRAWING AS POLYVINYL CHLORIDE (PVC) SHALL BE SDR 35 OR APPROVED EQUAL. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY NECESSARY FIELD LOCATES AND POTHOLING OF SUBSURFACE UTILITIES. ENGINEER AND CITY SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS. 14. CONTRACTOR SHALL COORDINATE ANY NECESSARY TELEPHONE, CABLE, FIBER, GAS, AND ELECTRIC LOWERINGS (OR RE-ROUTING) WITH THE RESPECTIVE UTILITY PROVIDERS. 15. CONTRACTOR TO COORDINATE FINAL LOCATION OF ALL GAS AND ELECTRIC METERS WITH ARCHITECT AND UTILITY PROVIDERS. EXISTING WATER MAIN LEGEND: W G T CTV EXISTING STORM SEWER EXISTING CABLE EXISTING TELEPHONE EXISTING GAS PROPOSED SEWER SERVICE S EXISTING SANITARY SEWER SS PROPOSED CURB & GUTTER PROPOSED WATER SERVICE EXISTING FIRE HYDRANT H Y D EASEMENT LINE PROPERTY BOUNDARY EXISTING LOTLINE W PROPOSED WATER MAIN PROPOSED SANITARY SEWER PROPOSED STORM SEWER PROPOSED ELECTRIC E PROPOSED FIRE SERVICE F EXISTING ELECTRIC E PROPOSED LOTLINE 9' 8' 26' EMERGENCY ACCESS EASEMENT 24' EMERGENCY ACCESS EASEMENT 24' EMERGENCY ACCESS EASEMENT 24' FL-FL 26' EMERGENCY ACCESS EASEMENT LOT 5 LOT 2 TRACT B LOT 6 LOT 1 TRACT A LOT 3 TRACT A TRACT A 19' 19' 9' 9' 17' 9' 9' 20' 15' 15' 8' 8' 9' 20' 19' 19' 9' 9' 15' 8' 19' 9' 17' 9' 15' 8' 19' 19' 9' 9' 15' 15' 8' 8' 19' 9' 19' 9' 8' 9' 8' 5' 8' 18' 9' 17' 9' 24' EMERGENCY ACCESS EASEMENT 24' FL-FL 5' WALK 6' SIDEWALK 6' SIDEWALK 12' SIDEWALK 12' SIDEWALK 12' SIDEWALK 5' SIDEWALK 12' SIDEWALK 12' SIDEWALK TYPE III BARRICADES ±27' FL-FL EXISTING FRONTAGE ROAD 24' FL-FL 24' EMERGENCY ACCESS EASEMENT 6' WALK 5' WALK 4' WALK (TYP.) 4' WALK (TYP.) WAYFINDING SIGN WAYFINDING SIGN WAYFINDING SIGN PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 30" VERTICAL CURB & GUTTER PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) 9' UTILITY EASEMENT 9' UTILITY EASEMENT 9' UTILITY EASEMENT 15' UTILITY EASEMENT 15' UTILITY EASEMENT UTILITY EASEMENT (WIDTH VARIES) UTILITY EASEMENT (WIDTH VARIES) 6' UTILITY & ACCESS EASEMENT 6' UTILITY & ACCESS EASEMENT BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) PROPOSED STAIRS PROPOSED STAIRS PROPOSED STAIRS PROPOSED STAIRS TRASH ENCLOSURE TRASH ENCLOSURE 2' CONCRETE CHASE PROPOSED STAIRS PROPOSED 18" VERTICAL CURB & GUTTER (TYP.) PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN PROPOSED 4' CONCRETE PAN LOT 4 5' WALK (TYP.) 8' 8' 2' CONCRETE CHASE 2' CONCRETE CHASE 2' CONCRETE CHASE EXISTING PRPA TRANSMISSION POLE (MIN. 30" CLEARANCE PROVIDED) MATCH EXISTING 30" VERTICAL CURB & GUTTER BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) BOULDER WALL (RE: LANDSCAPE) No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C200 PAVING PLAN A. Reese B. Ruch 1"=30' 4 NORTH ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 1. SEE DETAIL SHEETS FOR ADDITIONAL INFORMATION REGARDING CURBS AND PAVEMENT SECTIONS. 2. PAVEMENT MARKINGS SHALL BE PER CITY STANDARDS AND PROJECT SPECIFICATION MANUAL. 3. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 4. CONCRETE REMOVAL SHALL BE TO NEAREST PANEL, OR AS DIRECTED BY OWNER AND/OR CITY. 5. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 6. ALL PUBLIC CONCRETE SIDEWALKS SHALL BE 6" THICK. ALLEY DRIVEWAY/SIDEWALK CONCRETE SHALL BE 8" (MIN.) THICK. ACTUAL ALLEY CONCRETE THICKNESS SHALL BE BASED ON FINAL PAVEMENT DESIGN. 7. REFER TO SITE AND LANDSCAPE PLANS (BY OTHERS) FOR ADDITIONAL INFORMATION RELATED TO DECORATIVE PAVING, HARDSCAPES, AND OTHER SITE AMENITIES. PROPOSED VERTICAL CURB & GUTTER ACCESS RAMP w/ TRUNCATED DOMES EASEMENTS PUBLIC CONCRETE FLATWORK PROPERTY BOUNDARY PROPOSED LOT LINE EXISTING ROW ASPHALT PATCH PRIVATE CONCRETE FLATWORK PROPOSED ROW NOTES: LEGEND: LIGHT DUTY PAVING HEAVY DUTY PAVING CONCRETE PARKING PAVING G G G G G G G G G G G G G E E E E E W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W G G CTV E E E E E E E E E E E E E E E E G G G G G G G E E E E E E E E E E E E E E E E E E E E E E E E CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV CTV G G G G G G G G G G G G G G G T T T T T T T T T E E E E E E E E E E E E W W G G G G G G G G G G G BUS BUS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS C S H2O LID C.O. C.O. X X X X T X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X G M G X X T T MH V.P. WV WV AC G T MH OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE OHE X S MH MH MH ELEC H2O S S MH C MH S S S WV S VAULT ELEC E VAULT ELEC E VAULT ELEC E E ELEC S ELEC WV WV H2O WV WV H Y D C S C S C S C S W W W W W W W W W W W W W W W W W W W W W W W W D D D D W D H Y D ST ST D ENCHANTE ENTERPRISES LLC 2631 S COLLEGE AVE PLUTUS HOLDINGS LLC 2633 S COLLEGE AV. DRAKE ROAD (ROW VARIES) McCLELLAND DRIVE (37' ROW) COLLEGE AVENUE (ROW VARIES) THUNDERBIRD DRIVE (60' ROW) PROPOSED SAWCUT 18' UTILITY EASEMENT PER GHENT SUB. PLAT TO BE VACATED BY THIS PLAT 12' UTILITY EASEMENT PER MOORE ADD'N 1ST FILING TO BE VACATED BY THIS PLAT 3' PEDESTRIAN EASEMENT REC. NO. 98004057 PEDESTRIAN EASMENT REC. NO. 98004057 EXISTING GATE & CHAIN LINK FENCE TO BE REMOVED EXISTING SIGN TO BE RELOCATED EXISTING SAN MH RIM=5030.02 INV OUT=5018.33 (E) EXISTING SAN MH RIM=5027.14 INV IN=5017.12 (W) INV OUT=5017.10 (E) EXISTING 8" CLAY SANITARY EXISTING SAN MH RIM=5023.68 INV IN=5016.04 (W) INV IN=5015.90 (S) INV OUT=5015.85 (N) EXISTING 8" SANITARY EXISTING 10" CLAY SANITARY EXISTING SAN MH RIM=5022.16 INV IN=5012.69 (S) INV IN=5012.15 (W) INV OUT=5011.99 (E) EXISTING SAN MH RIM=5024.85 INV IN=501521 (NW) INV IN=5014.50 (W) INV OUT=5014.39 (E) EXISTING 18" CLAY SANITARY EXISTING SAN MH RIM=5030.72 INV IN=5017.47 (W) INV OUT=5017.22 (E) EXISTING 18" RCP STORM DRAIN EXISTING STM MH RIM=5021.61 INV IN=5018.91 (W) INV IN=5018.84 (S) INV OUT=5018.89 (N) EXISTING STM MH RIM=5022.26 INV IN=5019.63 (S) INV OUT=5019.60 (N) EXISTING 15" RCP STORM DRAIN EXISTING 15" RCP STORM DRAIN EXISTING 6" WATER EXISTING GATE & CHAIN LINK FENCE TO BE REMOVED EXISTING CHAIN LINK FENCE TO BE REMOVED EXISTING ASPHALT TO BE REMOVED EXISTING CHAIN LINK FENCE TO BE REMOVED EXISTING CHAIN LINK FENCE TO BE REMOVED EXISTING ASPHALT TO BE REMOVED EXISTING ASPHALT TO BE REMOVED EXISTING ASPHALT TO BE REMOVED EXISTING ASPHALT TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING BUILDING TO BE REMOVED EXISTING SHEDS TO BE REMOVED EXISTING GATE & CHAIN LINK FENCE TO BE REMOVED 6' EASEMENT PER GHENT SUBDIVISION PLAT TO BE VACATED 8' ALLEY ROW PER GHENT SUB. PLAT TO BE VACATED 3'x3' UTILITY EASEMENT REC. NO. 96030373 EXISTING BLOCK WALL TO BE REMOVED EXISTING BLOCK WALLS TO BE REMOVED EXISTING ASPHALT TO BE REMOVED EXISTING ASPHALT TO BE REMOVED EXISTING DRIVEWAY TO BE REMOVED EXISTING 15" RCP STORM DRAIN / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / EXISTING 12" WATER ±311 LF EXISTING 12" WATER TO BE REMOVED ±311 LF EXISTING 12" WATER TO BE REMOVED EXISTING STRIPING TO BE REMOVED EXISTING 30" VERTICAL CURB & GUTTER TO BE REMOVED EXISTING 30" VERTICAL CURB & GUTTER TO BE REMOVED EXISTING 30" VERTICAL CURB & GUTTER TO BE REMOVED ±66LF EXISTING 30" VERTICAL CURB & GUTTER TO BE REMOVED EXISTING CONCRETE TO BE REMOVED EXISTING 8" CLAY SANITARY EXISTING 12" WATER EXISTING 24" WATER EXISTING 24" WATER EXISTING 18" CLAY SANITARY EXISTING VERTICAL PIPES TO BE REMOVED EXISTING CONCRETE WALL TO BE REMOVED EXISTING CHAIN LINK FENCE TO BE REMOVED EXISTING LOT LINE TO BE VACATED PROPOSED SAWCUT ±64LF EXISTING 30" VERTICAL CURB & GUTTER TO BE REMOVED EXISTING 30" VERTICAL CURB & GUTTER TO BE REMOVED ±54LF EXISTING 30" VERTICAL CURB & GUTTER TO BE REMOVED EXISTING LOT LINE TO BE VACATED EXISTING GAS METERS TO BE REMOVED EXISTING UTILITY MANHOLE EXISTING CONCRETE WALL TO BE REMOVED 3'x3' UTILITY EASEMENT REC. NO. 96030373 EXISTING WATER SERVICES TO BE REMOVED EXISTING BUILDING TO BE REMOVED 3'x3' UTILITY EASEMENT REC. NO. 96030373 EXISTING 7' CONCRETE SIDEWALK TO BE REMOVED EXISTING 7' CONCRETE SIDEWALK TO BE REMOVED EXISTING 7' CONCRETE SIDEWALK TO BE REMOVED EXISTING 6' CONCRETE SIDEWALK TO BE REMOVED EXISTING 6' CONCRETE SIDEWALK TO BE REMOVED EXISTING 10' CONCRETE SIDEWALK TO BE REMOVED EXISTING 10' CONCRETE SIDEWALK TO BE REMOVED EXISTING 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER EXISTING 30" VERTICAL CURB & GUTTER APPROXIMATE LOCATION EXISTING FH EXISTING 10" CLAY SANITARY EXISTING GAS SERVICE TO BE REMOVED EXISTING WATER SERVICE TO BE REMOVED EXISTING PRPA TRANSMISSION POLE CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner C100 DEMOLITION PLAN EXISTING CONDITIONS & A. Reese B. Ruch 1"=30' 3 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 NORTH LEGEND: EXISTING STORM SEWER EXISTING VALVE EXISTING TELEPHONE PEDESTAL EXISTING TREES (TO REMAIN) FIELD SURVEY BY: EXISTING SANITARY SEWER SS EXISTING WATER W EXISTING FENCE X EXISTING WATER METER EXISTING FIRE HYDRANT EXISTING ELECTRIC VAULT PROPERTY BOUNDARY EXISTING RIGHT-OF-WAY EXISTING MAJOR CONTOUR EXISTING MINOR CONTOUR 5015 5013 H Y EXISTING TREES (TO BE REMOVED) EXISTING PAVEMENT TO BE REMOVED 1. ALL EXISTING TREES WITHIN THE LIMITS OF THE DEVELOPMENT AND WITHIN ANY NATURAL AREA BUFFER ZONES SHALL REMAIN AND BE PROTECTED UNLESS NOTED ON THESE PLANS FOR REMOVAL. 2. WITHIN THE DRIP LINE OF ANY PROTECTED EXISTING TREE, THERE SHALL BE NO CUT OR FILL OVER A FOUR-INCH DEPTH UNLESS A QUALIFIED ARBORIST OR FORESTER HAS EVALUATED AND APPROVED THE DISTURBANCE. 3. ALL PROTECTED EXISTING TREES SHALL BE PRUNED TO THE CITY OF FORT COLLINS FORESTRY STANDARDS. TREE PRUNING AND REMOVAL SHALL BE PERFORMED BY A BUSINESS THAT HOLDS A CURRENT CITY OF FORT COLLINS ARBORIST LICENSE WHERE REQUIRED BY CODE. 4. PRIOR TO AND DURING CONSTRUCTION, BARRIERS SHALL BE ERECTED AROUND ALL PROTECTED EXISTING TREES WITH SUCH BARRIERS TO BE OF ORANGE FENCING A MINIMUM OF FOUR (4) FEET IN HEIGHT, SECURED WITH METAL T-POSTS, NO CLOSER THAN SIX (6) FEET FROM THE TRUNK OR ONE-HALF (½) OF THE DRIP LINE, WHICHEVER IS GREATER. THERE SHALL BE NO STORAGE OR MOVEMENT OF EQUIPMENT, MATERIAL, DEBRIS OR FILL WITHIN THE FENCED TREE PROTECTION ZONE. 5. DURING THE CONSTRUCTION STAGE OF DEVELOPMENT, THE APPLICANT SHALL PREVENT THE CLEANING OF EQUIPMENT OR MATERIAL OR THE STORAGE AND DISPOSAL OF WASTE MATERIAL SUCH AS PAINTS, OILS, SOLVENTS, ASPHALT, CONCRETE, MOTOR OIL OR ANY OTHER MATERIAL HARMFUL TO THE LIFE OF A TREE WITHIN THE DRIP LINE OF ANY PROTECTED TREE OR GROUP OF TREES. 6. NO DAMAGING ATTACHMENT, WIRES, SIGNS OR PERMITS MAY BE FASTENED TO ANY PROTECTED TREE. 7. LARGE PROPERTY AREAS CONTAINING PROTECTED TREES AND SEPARATED FROM CONSTRUCTION OR LAND CLEARING AREAS, ROAD RIGHTS-OF-WAY AND UTILITY EASEMENTS MAY BE "RIBBONED OFF," RATHER THAN ERECTING PROTECTIVE FENCING AROUND EACH TREE AS REQUIRED IN SUBSECTION (G)(3) ABOVE. THIS MAY BE ACCOMPLISHED BY PLACING METAL T-POST STAKES A MAXIMUM OF FIFTY (50) FEET APART AND TYING RIBBON OR ROPE FROM STAKE-TO-STAKE ALONG THE OUTSIDE PERIMETERS OF SUCH AREAS BEING CLEARED. 8. THE INSTALLATION OF UTILITIES, IRRIGATION LINES OR ANY UNDERGROUND FIXTURE REQUIRING EXCAVATION DEEPER THAN SIX (6) INCHES SHALL BE ACCOMPLISHED BY BORING UNDER THE ROOT SYSTEM OF PROTECTED EXISTING TREES AT A MINIMUM DEPTH OF TWENTY-FOUR (24) INCHES. THE AUGER DISTANCE IS ESTABLISHED FROM THE FACE OF THE TREE (OUTER BARK) AND IS SCALED FROM TREE DIAMETER AT BREAST HEIGHT AS DESCRIBED IN THE CHART BELOW: 9. ALL TREE REMOVAL SHOWN SHALL BE COMPLETED OUTSIDE OF THE SONGBIRD NESTING SEASON (FEB 1 - JULY 31) OR CONDUCT A SURVEY OF TREES ENSURING NO ACTIVE NESTS IN THE AREA. 10. REFER TO LANDSCAPE AND IRRIGATION PLANS FOR ADDITIONAL TREE PROTECTION MEASURES. TREE PROTECTION NOTES: NOTES: 1. THE SIZE, TYPE AND LOCATION OF ALL KNOWN UNDERGROUND UTILITIES ARE APPROXIMATE WHEN SHOWN ON THESE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE EXISTENCE OF ALL UNDERGROUND UTILITIES IN THE AREA OF THE WORK. BEFORE COMMENCING NEW CONSTRUCTION, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL UNDERGROUND UTILITIES AND SHALL BE RESPONSIBLE FOR ALL UNKNOWN UNDERGROUND UTILITIES. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING DEMOLITION, REMOVAL, REPLACEMENT, AND DISPOSAL OF ALL FACILITIES AND MATERIAL. 3. CONTRACTOR IS ENCOURAGED TO PERFORM DEMOLITION IN A MANNER THAT MAXIMIZES SALVAGE, RE-USE, AND RECYCLING OF MATERIALS. THIS INCLUDES APPROPRIATE SORTING AND STORING. IN PARTICULAR, DEMOLISHED CONCRETE, ASPHALT, AND BASE COURSE SHOULD BE RECYCLED IF POSSIBLE. THE CITY OF FORT COLLINS STREET DEPARTMENT OPERATES A CRUSHING OPERATION THAT WILL ACCEPT CONCRETE MATERIAL AT NO COST FOR CRUSHING AND RE-USE AS RECYCLED AGGREGATE. THIS OPERATION IS LOCATED AT 1380 HOFFMAN MILL ROAD AND CAN BE REACHED AT (970) 482-1249. 4. ALL SYMBOLS ARE ONLY GRAPHICALLY REPRESENTED AND ARE NOT TO SCALE. 5. CONTACT THE PROJECT SURVEYOR FOR ANY INQUIRIES RELATED TO THE EXISTING SITE SURVEY. 6. LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. 7. CONCRETE REMOVAL SHALL BE TO NEAREST PANEL, OR AS DIRECTED BY OWNER AND/OR CITY. 8. ADDITIONAL TREES NOT SHOWN ON THESE PLANS MAY EXIST AND MAY REQUIRE REMOVAL. COORDINATION OF WHICH TREES ARE TO REMAIN AND WHICH ARE TO BE REMOVED SHOULD BE COORDINATED WITH THE CITY FORESTER. REFER TO LANDSCAPE PLANS AND TREE MITIGATION PLAN FOR ADDITIONAL INFORMATION. 9. CONTRACTOR SHALL COORDINATE WITH FORT COLLINS UTILITY FIELD OPERATIONS DEPARTMENT AT (970) 221-6700 FOR WATER AND SEWER SERVICE ABANDONMENT. 10. REFER TO SITE AND LANDSCAPE PLANS FOR ADDITIONAL INFORMATION. TREE DIAMETER AT BREAST HEIGHT (INCHES) AUGER DISTANCE FROM FACE OF TREE (FEET) 0-2 1 3-4 2 5-9 5 10-14 10 15-19 12 OVER 19 15 S O W VAULT ELEC ( IN FEET ) 1 inch = ft. 30 0 30 Feet 30 60 90 T EXISTING CABLE CTV EXISTING ELECTRIC E EXISTING OVERHEAD UTILITY OHU NORTHERN ENGINEERING PROJECT NO. 249-015 DATE: FEBRUARY 2012 ADDITIONAL TOPO: NORTHERN ENGINEERING PROJECT NO. 379-072 DATE: NOVEMBER 2017 NORTHERN ENGINEERING PROJECT NO. 379-072 DATE: MAY 2018 EXISTING GAS G GENERAL & CONSTRUCTION NOTES A. Reese B. Ruch N/A 2 CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. CALL UTILITY NOTIFICATION CENTER OF COLORADO Know what'sbelow. Call before you dig. R City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner A. GENERAL NOTES 1. All materials, workmanship, and construction of public improvements shall meet or exceed the standards and specifications set forth in the Larimer County Urban Area Street Standards and applicable state and federal regulations. Where there is conflict between these plans and the specifications, or any applicable standards, the most restrictive standard shall apply. All work shall be inspected and approved by the City of Fort Collins. 2. All references to any published standards shall refer to the latest revision of said standard, unless specifically stated otherwise. 3. These public improvement construction plans shall be valid for a period of three years from the date of approval by the City of Fort Collins Engineer. Use of these plans after the expiration date will require a new review and approval process by the City of Fort Collins prior to commencement of any work shown in these plans. 4. The engineer who has prepared these plans, by execution and/or seal hereof, does hereby affirm responsibility to the City of Fort Collins, as beneficiary of said engineer's work, for any errors and omissions contained in these plans, and approval of these plans by the City of Fort Collins Engineer shall not relieve the engineer who has prepared these plans of all such responsibility. Further, to the extent permitted by law, the engineer hereby agrees to hold harmless and indemnify the City of Fort Collins, and its officers and employees, from and against all liabilities, claims, and demands which may arise from any errors and omissions contained in these plans. 5. All storm sewer construction, as well as power and other "dry" utility installations, shall conform to the City of Fort Collins standards and specifications current at the date of approval of the plans by the City of Fort Collins Engineer. 6. The type, size, location and number of all known underground utilities are approximate when shown on the drawings. It shall be the responsibility of the Developer to verify the existence and location of all underground utilities along the route of the work before commencing new construction. The Developer shall be responsible for unknown underground utilities. 7. The Developer shall contact the Utility Notification Center of Colorado (UNCC) at 1-800-922-1987, at least 2 working days prior to beginning excavation or grading, to have all registered utility locations marked. Other unregistered utility entities (i.e. ditch / irrigation company) are to be located by contacting the respective representative. Utility service laterals are also to be located prior to beginning excavation or grading. It shall be the responsibility of the Developer to relocate all existing utilities that conflict with the proposed improvements shown on these plans. 8. The Developer shall be responsible for protecting all utilities during construction and for coordinating with the appropriate utility company for any utility crossings required. 9. If a conflict exists between existing and proposed utilities and/or a design modification is required, the Developer shall coordinate with the engineer to modify the design. Design modification(s) must be approved by the City of Fort Collins prior to beginning construction. 10. The Developer shall coordinate and cooperate with the City of Fort Collins, and all utility companies involved, to assure that the work is accomplished in a timely fashion and with a minimum disruption of service. The Developer shall be responsible for contacting, in advance, all parties affected by any disruption of any utility service as well as the utility companies. 11. No work may commence within any public storm water, sanitary sewer or potable water system until the Developer notifies the utility provider. Notification shall be a minimum of 2 working days prior to commencement of any work. At the discretion of the water utility provider, a pre-construction meeting may be required prior to commencement of any work. 12. The Developer shall sequence installation of utilities in such a manner as to minimize potential utility conflicts. In general, storm sewer and sanitary sewer should be constructed prior to installation of the water lines and dry utilities. 13. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the Water Utility. 14. A State Construction Dewatering Wastewater Discharge Permit is required if dewatering is required in order to install utilities or if water is discharged into a storm sewer, channel, irrigation ditch or any waters of the United States. 15. The Developer shall comply with all terms and conditions of the Colorado Permit for Storm Water Discharge (Contact Colorado Department of Health, Water Quality Control Division, (303) 692-3590), the Storm Water Management Plan, and the Erosion Control Plan. 16. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 17. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must be submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. 18. The City of Fort Collins shall not be responsible for any damages or injuries sustained in this Development as a result of groundwater seepage, whether resulting from groundwater flooding, structural damage or other damage unless such damage or injuries are sustained as a result of the City of Fort Collins failure to properly maintain its water, wastewater, and/or storm drainage facilities in the development. 19. All recommendations of the Preliminary Drainage Report for Drake Redevelopment, dated July 25, 2018 by Northern Engineering shall be followed and implemented. 20. Temporary erosion control during construction shall be provided as shown on the Erosion Control Plan. All erosion control measures shall be maintained in good repair by the Developer, until such time as the entire disturbed areas is stabilized with hard surface or landscaping. 21. The Developer shall be responsible for insuring that no mud or debris shall be tracked onto the existing public street system. Mud and debris must be removed within 24 hours by an appropriate mechanical method (i.e. machine broom sweep, light duty front-end loader, etc.) or as approved by the the City of Fort Collins street inspector. 22. No work may commence within any improved or unimproved public Right-of-Way until a Right-of-Way Permit or Development Construction Permit is obtained, if applicable. 23. The Developer shall be responsible for obtaining all necessary permits for all applicable agencies prior to commencement of construction. The Developer shall notify the the City of Fort Collins Inspector (Fort Collins - 221-6605) and the City of Fort Collins Erosion Control Inspector (Fort Collins - 221-6700) at least 2 working days prior to the start of any earth disturbing activity, or construction on any and all public improvements. If the City of Fort Collins Engineer is not available after proper notice of construction activity has been provided, the Developer may commence work in the Engineer absence. However, the City of Fort Collins reserves the right not to accept the improvement if subsequent testing reveals an improper installation. 24. The Developer shall be responsible for obtaining soils tests within the Public Right-of-Way after right of way grading and all utility trench work is complete and prior to the placement of curb, gutter, sidewalk and pavement. If the final soils/pavement design report does not correspond with the results of the original geotechnical report, the Developer shall be responsible for a re-design of the subject pavement section or, the Developer may use the City of Fort Collins' default pavement thickness section(s). Regardless of the option used, all final soils/pavement design reports shall be prepared by a licensed Professional Engineer. The final report shall be submitted to the Inspector a minimum of 10 working days prior to placement of base and asphalt. Placement of curb, gutter, sidewalk, base and asphalt shall not occur until the City of Fort Collins Engineer approves the final report. 25. The contractor shall hire a licensed engineer or land surveyor to survey the constructed elevations of the street subgrade and the gutter flowline at all intersections, inlets, and other locations requested by the the City of Fort Collins inspector. The engineer or surveyor must certify in a letter to the City of Fort Collins that these elevations conform to the approved plans and specifications. Any deviations shall be noted in the letter and then resolved with the City of Fort Collins before installation of base course or asphalt will be allowed on the streets. 26. All utility installations within or across the roadbed of new residential roads must be completed prior to the final stages of road construction. For the purposes of these standards, any work except c/g above the subgrade is considered final stage work. All service lines must be stubbed to the property lines and marked so as to reduce the excavation necessary for building connections. 27. Portions of Larimer County are within overlay districts. The Larimer County Flood Plain Resolution should be referred to for additional criteria for roads within these districts. 28. All road construction in areas designated as Wild Fire Hazard Areas shall be done in accordance with the construction criteria as established in the Wild Fire Hazard Area Mitigation Regulations in force at the time of final plat approval. 29. Prior to the commencement of any construction, the contractor shall contact the Local Entity Forester to schedule a site inspection for any tree removal requiring a permit. 30. The Developer shall be responsible for all aspects of safety including, but not limited to, excavation, trenching, shoring, traffic control, and security. Refer to OSHA Publication 2226, Excavating and Trenching. 31. The Developer shall submit a Construction Traffic Control Plan, in accordance with MUTCD, to the appropriate Right-of-Way authority. (The City of Fort Collins, Larimer County, Colorado), for approval, prior to any construction activities within, or affecting, the Right-of-Way. The Developer shall be responsible for providing any and all traffic control devices as may be required by the construction activities. 32. Prior to the commencement of any construction that will affect traffic signs of any type, the contractor shall contact the City of Fort Collins Traffic Operations Department, who will temporarily remove or relocate the sign at no cost to the contractor, however, if the contractor moves the traffic sign then the contractor will be charged for the labor, materials and equipment to reinstall the sign as needed. 33. The Developer is responsible for all costs for the initial installation of traffic signing and striping for the Development related to the Development's local street operations. In addition, the Developer is responsible for all costs for traffic signing and striping related to directing traffic access to and from the Development. 34. There shall be no site construction activities on Saturdays, unless specifically approved by the City of Fort Collins Engineer, and no site construction activities on Sundays or holidays, unless there is prior written approval by City of Fort Collins. 35. The Developer is responsible for providing all labor and materials necessary for the completion of the intended improvements, shown on these drawings, or designated to be provided, installed, or constructed, unless specifically noted otherwise. 36. Dimensions for layout and construction are not to be scaled from any drawing. If pertinent dimensions are not shown, contact the Designer for clarification, and annotate the dimension on the as-built record drawings. 37. The Developer shall have, onsite at all times, one (1) signed copy of the approved plans, one (1) copy of the appropriate standards and specifications, and a copy of any permits and extension agreements needed for the job. 38. If, during the construction process, conditions are encountered which could indicate a situation that is not identified in the plans or specifications, the Developer shall contact the Designer and the City of Fort Collins Engineer immediately. 39. The Developer shall be responsible for recording as-built information on a set of record drawings kept on the construction site, and available to the Larimer County's Inspector at all times. Upon completion of the work, the contractor(s) shall submit record drawings to the City of Fort Collins Engineer. 40. The Designer shall provide, in this location on the plan, the location and description of the nearest survey benchmarks (2) for the project as well as the basis of bearings. The information shall be as follows: PROJECT DATUM: NAVD88 City of Fort Collins Benchmark 21-92 Northwest corner of West Drake Rd. and Research Blvd., on a power tower base. Elev.= 5042.84 City of Fort Collins Benchmark 14-97 Approximately 100 feet west of the intersection of Centre Ave. and Research blvd.,on the west end of the south headwall on Centre Ave. Elev.= 5051.76 Please Note: This plan set is using NAVD88 for a vertical datum. Surrounding developments have used NGVD29 Unadjusted for their vertical datums. If NGVD29 Unadjusted Datum is required for any purpose, the following equation should be used: NGVD29 Unadjusted = NAVD88 - 3.17' Basis of Bearings The Basis of Bearings is the North line of the Northeast Quarter, Section 26-7-69, as bearing N 89°30' W. 41. All stationing is based on centerline of roadways unless otherwise noted. 42. Damaged curb, gutter and sidewalk existing prior to construction, as well as existing fences, trees, streets, sidewalks, curbs and gutters, landscaping, structures, and improvements destroyed, damaged or removed due to construction of this project, shall be replaced or restored in like kind at the Developer's expense, unless otherwise indicated on these plans, prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 43. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the City of Fort Collins Construction Inspector before any cuts are made. Patching shall be done in accordance with the City of Fort Collins Street Repair Standards. The finished patch shall blend in smoothly into the existing surface. All large patches shall be paved with an asphalt lay-down machine. In streets where more than one cut is made, an overlay of the entire street width, including the patched area, may be required. The determination of need for a complete overlay shall be made by the Larimer County Engineer and/or the City of Fort Collins Inspector at the time the cuts are made. 44. Upon completion of construction, the site shall be cleaned and restored to a condition equal to, or better than, that which existed before construction, or to the grades and condition as required by these plans. 45. Standard Handicap ramps are to be constructed at all curb returns and at all "T" intersections. 46. After acceptance by the City of Fort Collins, public improvements depicted in these plans shall be guaranteed to be free from material and workmanship defects for a minimum period of two years from the date of acceptance. 47. The City of Fort Collins shall not be responsible for the maintenance of roadway and appurtenant improvements, including storm drainage structures and pipes, for the following private streets: N.A. 48. Approved Variances are listed as follows: N.A. CONSTRUCTION NOTES A. Grading and Erosion Control Notes 1. The erosion control inspector must be notified at least twenty-four (24) hours prior to any construction on this site. 2. There shall be no earth-disturbing activity outside the limits designated on the accepted plans. 3. All required perimeter silt and construction fencing shall be installed prior to any land disturbing activity (stockpiling, stripping, grading, etc). All other required erosion control measures shall be installed at the appropriate time in the construction sequence as indicated in the approved project schedule, construction plans, and erosion control report. 4. At all times during construction, the Developer shall be responsible for preventing and controlling on-site erosion including keeping the property sufficiently watered so as to minimize wind blown sediment. The Developer shall also be responsible for installing and maintaining all erosion control facilities shown herein. 5. Pre-disturbance vegetation shall be protected and retained wherever possible. Removal or disturbance of existing vegetation shall be limited to the area(s) required for immediate construction operations, and for the shortest practical period of time. 6. All soils exposed during land disturbing activity (stripping, grading, utility installations, stockpiling, filling, etc.) shall be kept in a roughened condition by ripping or disking along land contours until mulch, vegetation, or other permanent erosion control BMPs are installed. No soils in areas outside project street rights-of-way shall remain exposed by land disturbing activity for more than thirty (30) days before required temporary or permanent erosion control (e.g. seed/mulch, landscaping, etc.) is installed, unless otherwise approved by the City/County. 7. In order to minimize erosion potential, all temporary (structural) erosion control measures shall: a. Be inspected at a minimum of once every two (2) weeks and after each significant storm event and repaired or reconstructed as necessary in order to ensure the continued performance of their intended function. b. Remain in place until such time as all the surrounding disturbed areas are sufficiently stabilized as determined by the erosion control inspector. c. Be removed after the site has been sufficiently stabilized as determined by the erosion control inspector. 8. When temporary erosion control measures are removed, the Developer shall be responsible for the clean up and removal of all sediment and debris from all drainage infrastructure and other public facilities. 9. The contractor shall immediately clean up any construction materials inadvertently deposited on existing streets, sidewalks, or other public rights of way, and make sure streets and walkways are cleaned at the end of each working day. 10. All retained sediments, particularly those on paved roadway surfaces, shall be removed and disposed of in a manner and location so as not to cause their release into any waters of the United States. 11. No soil stockpile shall exceed ten (10) feet in height. All soil stockpiles shall be protected from sediment transport by surface roughening, watering, and perimeter silt fencing. Any soil stockpile remaining after thirty (30) days shall be seeded and mulched. 12. The stormwater volume capacity of detention ponds will be restored and storm sewer lines will be cleaned upon completion of the project and before turning the maintenance over to the City/County or Homeowners Association (HOA). 13. City Ordinance and Colorado Discharge Permit System (CDPS) requirements make it unlawful to discharge or allow the discharge of any pollutant or contaminated water from construction sites. Pollutants include, but are not limited to discarded building materials, concrete truck washout, chemicals, oil and gas products, litter, and sanitary waste. The developer shall at all times take whatever measures are necessary to assure the proper containment and disposal of pollutants on the site in accordance with any and all applicable local, state, and federal regulations. 14. A designated area shall be provided on site for concrete truck chute washout. The area shall be constructed so as to contain washout material and located at least fifty (50) feet away from any waterway during construction. Upon completion of construction activities the concrete washout material will be removed and properly disposed of prior to the area being restored. 15. Conditions in the field may warrant erosion control measures in addition to what is shown on these plans. The Developer shall implement whatever measures are determined necessary, as directed by the City. 16. For additional information see separate Stormwater Management Plan / Erosion Control Report for Drake Redevelopment. B. Street Improvement Notes 1. All street construction is subject to the General Notes on the cover sheet of these plans as well as the Street Improvements Notes listed here. 2. A paving section design, signed and stamped by a Colorado licensed Engineer, must be submitted to the City of Fort Collins Engineer for approval, prior to any street construction activity, (full depth asphalt sections are not permitted at a depth greater than 8 inches of asphalt). The job mix shall be submitted for approval prior to placement of any asphalt. 3. Where proposed paving adjoins existing asphalt, the existing asphalt shall be saw cut, a minimum distance of 12 inches from the existing edge, to create a clean construction joint. The Developer shall be required to remove existing pavement to a distance where a clean construction joint can be made. Wheel cuts shall not be allowed unless approved by the City of Fort Collins Engineer in Fort Collins. 4. Street subgrades shall be scarified the top 12 inches and re-compacted prior to subbase installation. No base material shall be laid until the subgrade has been inspected and approved by the City of Fort Collins Engineer. 5. Ft. Collins only. Valve boxes and manholes are to be brought up to grade at the time of pavement placement or overlay. Valve box adjusting rings are not allowed. 6. When an existing asphalt street must be cut, the street must be restored to a condition equal to or better than its original condition. The existing street condition shall be documented by the Inspector before any cuts are made. Cutting and patching shall be done in conformance with Chapter 25, Reconstruction and Repair. The finished patch shall blend smoothly into the existing surface. The determination of need for a complete overlay shall be made by the City of Fort Collins Engineer. All overlay work shall be coordinated with adjacent landowners such that future projects do not cut the new asphalt overlay work. 7. All traffic control devices shall be in conformance with these plans or as otherwise specified in M.U.T.C.D. (including Colorado supplement) and as per the Right-of-Way Work Permit traffic control plan. 8. The Developer is required to perform a gutter water flow test in the presence of the City of Fort Collins Inspector and prior to installation of asphalt. Gutters that hold more than 1/4 inch deep or 5 feet longitudinally, of water, shall be completely removed and reconstructed to drain properly. 9. Prior to placement of H.B.P. or concrete within the street and after moisture/density tests have been taken on the subgrade material (when a full depth section is proposed) or on the subgrade and base material (when a composite section is proposed), a mechanical "proof roll" will be required. The entire subgrade and/or base material shall be rolled with a heavily loaded vehicle having a total GVW of not less than 50,000 lbs. and a single axle weight of at least 18,000 lbs. with pneumatic tires inflated to not less that 90 p.s.i.g. "Proof roll" vehicles shall not travel at speeds greater than 3 m.p.h. Any portion of the subgrade or base material which exhibits excessive pumping or deformation, as determined by the City of Fort Collins Engineer, shall be reworked, replaced or otherwise modified to form a smooth, non-yielding surface. The City of Fort Collins Engineer shall be notified at least 24 hours prior to the "proof roll." All "proof rolls" shall be preformed in the presence of an Inspector. C. Traffic Signing and Pavement Marking Construction Notes 1. All signage and marking is subject to the General Notes on the cover sheet of these plans, as well as the Traffic Signing and Marking Construction Notes listed here. 2. All symbols, including arrows, ONLYS, crosswalks, stop bars, etc. shall be pre-formed thermo-plastic. 3. All signage shall be per the City of Fort Collins Standards and these plans or as otherwise specified in MUTCD. 4. All lane lines for asphalt pavement shall receive two coats of latex paint with glass beads. 5. All lane lines for concrete pavement should be epoxy paint. 6. Prior to permanent installation of traffic striping and symbols, the Developer shall place temporary tabs or tape depicting alignment and placement of the same. Their placement shall be approved by the City of Fort Collins Traffic Engineer prior to permanent installation of striping and symbols. 7. Pre-formed thermo-plastic applications shall be as specified in these Plans and/or these Standards. 8. Epoxy applications shall be applied as specified in CDOT Standard Specifications for Road and Bridge Construction. 9. All surfaces shall be thoroughly cleaned prior to installation of striping or markings. 10. All sign posts shall utilize break-away assemblies and fasteners per the Standards. 11. A field inspection of location and installation of all signs shall be performed by the City of Fort Collins Traffic Engineer. All discrepancies identified during the field inspection must be corrected before the 2-year warranty period will begin. 12. The Developer installing signs shall be responsible for locating and protecting all underground utilities. 13. Special care shall be taken in sign location to ensure an unobstructed view of each sign. 14. Signage and striping has been determined by information available at the time of review. Prior to initiation of the warranty period,the City of Fort Collins Traffic Engineer reserves the right to require additional signage and/or striping if the City of Fort Collins Traffic Engineer determines that an unforeseen condition warrants such signage according to the MUTCD or the CDOT M and S Standards. All signage and striping shall fall under the requirements of the 2-year warranty period for new construction (except fair wear on traffic markings). 15. Sleeves for sign posts shall be required for use in islands/medians. Refer to Chapter 14, Traffic Control Devices, for additional detail. D. Storm Drainage Notes 1. The City of Fort Collins shall not be responsible for the maintenance of storm drainage facilities located on private property. Maintenance of onsite drainage facilities shall be the responsibility of the property owner(s). 2. All recommendations of the Preliminary Drainage Report for Drake Redevelopment, dated July 25, 2018 by Northern Engineering shall be followed and implemented. 3. Prior to final inspection and acceptance by the City of Fort Collins, certification of the drainage facilities, by a registered engineer, must by submitted to and approved by the Stormwater Utility Department. Certification shall be submitted to the Stormwater Utility Department at least two weeks prior to the release of a certificate of occupancy for single family units. For commercial properties, certification shall by submitted to the Stormwater Utility Department at least two weeks prior to the release of any building permits in excess of those allowed prior to certification per the Development Agreement. E. Utility Notes 1. All waterline and sanitary sewer construction shall conform to the City of Fort Collins Utility standards and specifications current to date of construction. 2. The minimum cover over water lines is 4.5 feet and the maximum cover is 5.5 feet unless otherwise noted in the plans and approved by the water utility. 3. Water mains shall be poly-wrapped D.I.P, or PVC with tracer wire. 4. HDPE pipe may be used for 1-1/2 and 2 inch water services. The pipe shall meet the standards of AWWA 901, NSF Standard 61 and ASTM. The HDPE pipe shall be SDR 9 having a pressure rating of 200 psi. Stiffeners shall be used at all fittings and connections. Tracer wire shall be installed with the HDPE service, and shall extend up the curb stop. The curb stop shall be covered with a metal valve box and "water" lid per City Water Detail 11A. PROJECT TEAM: SITE ENGINEER Northern Engineering Services, Inc. Andy Reese 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 SURVEYOR CONTACT INFORMATION PROJECT TEAM: SHEET INDEX E N G I N E E R I N G N O R T H E RN PRELIMINARY UTILITY PLANS FOR City Engineer Date Date Date Date Date Stormwater Utility Parks & Recreation Traffic Engineer Date APPROVED: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: CHECKED BY: Water & Wastewater Utility City of Fort Collins, Colorado UTILITY PLAN APPROVAL Environmental Planner UTILITY CONTACT LIST: * UTILITY COMPANY * This list is provided as a courtesy reference only. Northern Engineering Services assumes no responsibility for the accuracy or completeness of this list. In no way shall this list relinquish the Contractor's responsibility for locating all utilities prior to commencing any construction activity. Please contact the Utility Notification Center of Colorado (UNCC) at 811 for additional information. PHONE NUMBER GAS----------------- Xcel Energy----------------------------- Stephanie Rich (970) 225-7857 ELECTRIC-------- City of Fort Collins Light & Power-- Rob Irish (970) 221-6878 CABLE------------- Comcast---------------------------------- Don Kapperman (970) 567-0425 TELECOM.--------CenturyLink------------------------------- William Johnson (970) 377-6401 WATER------------ City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 WASTEWATER--City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 STORMWATER- City of Fort Collins Utilities----------- Shane Boyle (970) 221-6339 PROJECT LOCATION DRAKE REDEVELOPMENT Northern Engineering Services, Inc. Bob Tessely, PLS 301 North Howes Street, Suite 100 Fort Collins, Colorado 80521 (970) 221-4158 E N G I N E E R I N G N O R T H E RN C001 COVER SHEET C002 GENERAL & CONSTRUCTION NOTES C100 EXISTING CONDITIONS & DEMOLITION PLAN C200 PAVING PLAN C300 OVERALL UTILITY PLAN C301-C303 UTILITY PLAN C400 OVERALL GRADING PLAN C401-C408 GRADING PLAN C500 DRAKE ROAD STRIPING & SIGNAGE PLAN C600 EROSION CONTROL PLAN C601 EROSION CONTROL DETAILS C700 DRAINAGE EXHIBIT Brinkman Partners Todd Parker 3528 Precision Drive, Suite 100 Fort Collins, CO 80528 (970) 267-0954 PLANNER/ LANDSCAPE ARCHITECT Russell+Mills Studios Shelley La Mastra, RLA 506 S College Ave, Unit A Fort Collins, CO 80524 (970) 484-8855 ARCHITECT OZ Architecture Eduardo Illanes, AIA 3003 Larimer Street Denver, CO 80205 (303) 579-1558 MECHANICAL/PLUMBING The Ballard Group, Inc. Mechanical Consulting Engineers John Blair 2525 South Wadsworth Blvd., Suite 200 Lakewood, CO 80227 303-988-4514 No. Revisions: By: Date: REVIEWED BY: N. Haws DESIGNED BY: DRAWN BY: SCALE: DATE: 07/25/18 PROJECT: 379-072 Sheet DRAKE REDEVELOPMENT These drawings are instruments of service provided by Northern Engineering Services, Inc. and are not to be used for any type of construction unless signed and sealed by a Professional Engineer in the employ of Northern Engineering Services, Inc. NOT FOR CONSTRUCTION REVIEW SET 07/25/18 E N G I N E E R I N G N O R T H E RN FORT COLLINS: 301 North Howes Street, Suite 100, 80521 GREELEY: 820 8th Street, 80631 970.221.4158 northernengineering.com of 21 C001 COVER SHEET A. Reese B. Ruch N/A 1 TRACTS OF LAND LOCATED IN THE NORTHEAST QUARTER OF SECTION 26, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH P.M., CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO