HomeMy WebLinkAboutFTC RAM'S CROSSING, WTE (VERIZON) - BASIC DEVELOPMENT REVIEW - BDR180027 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSFTC RAMS CROSSING
808 W PROSPECT RD
FORT COLLINS, COLORADO 80525
NEW ROOFTOP MACRO
ZONING DRAWINGS
VICINITY MAP
PROJECT
AREA
SITE DIRECTIONS
FROM SOUTH VAUGHN WAY MERGE ONTO 1-225 N, TAKE EXIT 12A TO MERGE ONTO I-70 W, KEEP
RIGHT AT THE FORK TO CONTINUE ON I-270W, TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FT.
COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W, TURN LEFT ONTO S COLLEGE AVE, TURN
RIGHT ONTO W LAKE ST, TURN LEFT ONTO CENTRE AVE , TURN RIGHT ONTO W PROSPECT RD,
SITE WILL BE ON YOUR RIGHT.
FORT COLLINS, COLORADO
CLIENT
PROPERTY OWNER
VERIZON WIRELESS REAL ESTATE
9656 S. PROSPERITY RD.
WEST JORDAN, UT 84088
CONTACT: BRANDON KISER
PHONE: 801-260-8700
ROBIN & CHRISTIAN BACHELET
PHONE: 970-566-2586
EMAIL: RBACHELET@MAC.COM
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: KENT McDERMOTT
EMAIL: KENT.McDERMOTT@VERIZONWIRELESS.COM
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
LRK CONSULTING
1196 GRANT ST. UNIT 313
DENVER, CO 80203
CONTACT: RYAN SAGAR
PHONE: 219-477-0099
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2015 (W/ LOCAL AMENDMENTS)
NEC 2017
NFPA-1 (2006)
U - UTILITY
IIB
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
USE GROUP:
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
PHOTOSIMULATION
VIEWS
PH-1
2
2
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING SOUTHEAST)
N.T.S.
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTHEAST)
N.T.S.
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
PHOTOSIMULATION
VIEWS
PH-2
3
2
PH-2
PHOTOSIMULATION VIEW (AFTER, LOOKING NORTH)
N.T.S.
1
PH-2
PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTH)
N.T.S.
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
PHOTOSIMULATION
VIEWS
PH-3
4
2
PH-3
PHOTOSIMULATION VIEW (AFTER, LOOKING NORTHWEST)
N.T.S.
1
PH-3
PHOTOSIMULATION VIEW (BEFORE, LOOKING NORTHWEST)
N.T.S.
E
Y
GM
EM
SB
5
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
N
1
Z-1
SITE PLAN
SCALE: 1"=30'-0"
1 inch = 30ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
SITE PLAN
Z-1
5
LEGEND
W W W
SS SS SS
F F F
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES,
LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR
OTHER PUBLIC AUTHORITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND
INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR
MUNICIPAL AUTHORITIES.
3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING,
OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF
BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID
DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY
FOR THE OVERALL INTENT OF THESE DRAWINGS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING
SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE
CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF
CONSTRUCTION OF THIS FACILITY.
5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL
MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT.
ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS.
6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID
TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH
THE CONTRACT DOCUMENTS.
7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED
"BOUNDARY DETAIL" BY RLF CONSULTING, DATED 07/19/17.
8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN
STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE
PROPOSED.
9. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO
HANDICAP ACCESS REQUIRED).
11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR
SANITARY SERVICE.
12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER.
13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF
ENGINEERING PRIOR TO INSTALLATION.
14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2012
REQUIREMENTS.
15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL.
16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES
PRIOR TO EXCAVATING.
17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT
AND CONTACT OWNERS REPRESENTATIVE.
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
SB
E
E
F F F
F
F F
F F F F F F F F F F F F F F F F F
E
E
E E E E E E E E E E E E E E E E E
10'-0"
10'-0"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
1
Z-3
WEST SIDE EQUIPMENT PLAN
SCALE: 1/8"=1'-0"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
1/8 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
4 0 2 4 8 16
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
EQUIPMENT PLAN
49'-11"
47'-4"
42'-0"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
2
Z-4
PROPOSED NORTH ELEVATION
SCALE: 1/16"=1'-0"
1
Z-4
EXISTING NORTH ELEVATION
SCALE: 1/16"=1'-0"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
8 0 4 8 16 32
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ELEVATIONS
Z-4
8
PROPOSED 8' VERIZON ANTENNA
MOUNTED ON NON-PENETRATING SLED MOUNT
(TYP 3 PER SECTOR)
49'-11"
42'-0"
47'-4"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
2
Z-5
PROPOSED EAST ELEVATION
SCALE: 1/16"=1'-0"
1
Z-5
EXISTING EAST ELEVATION
SCALE: 1/16"=1'-0"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
8 0 4 8 16 32
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ELEVATIONS
(CONTINUED)
Z-5
9
PROPOSED 8' VERIZON ANTENNA
MOUNTED ON NON-PENETRATING SLED MOUNT
49'-11"
46'-10"
41'-5"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
2
Z-6
PROPOSED SOUTH ELEVATION
SCALE: 1/16"=1'-0"
1
Z-6
EXISTING SOUTH ELEVATION
SCALE: 1/16"=1'-0"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
8 0 4 8 16 32
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ELEVATIONS
(CONTINUED)
Z-6
10
PROPOSED 8' VERIZON ANTENNA
MOUNTED ON NON-PENETRATING SLED MOUNT (TYP 3
49'-11"
46'-10"
41'-5"
THIS DRAWING DOES NOT INCLUDE NECESSARY
COMPONENTS FOR CONSTRUCTION SAFETY. ALL
CONSTRUCTION MUST BE DONE IN COMPLIANCE
WITH THE OCCUPATIONAL SAFETY AND HEALTH
ACT OF 1970 AND ALL RULES AND REGULATIONS
PROTECT YOURSELF, GIVE THREE
WORKING DAYS NOTICE
THERE TO APPURTENANT.
Know what's below.
Call before you dig.
2
Z-7
PROPOSED WEST ELEVATION
SCALE: 1/16"=1'-0"
1
Z-7
EXISTING WEST ELEVATION
SCALE: 1/16"=1'-0"
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
1/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
8 0 4 8 16 32
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
ELEVATIONS
(CONTINUED)
Z-7
11
PROPOSED 8' VERIZON ANTENNA
MOUNTED ON NON-PENETRATING SLED MOUNT (TYP 3
10'-1" ±
10'-3" ±
17'-7" ±
10'-3" ±
17'-0" ±
10'-3" ±
12'-11" ±
10'-3" ±
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
CONCEALMENT SHROUD
DETAILS
Z-8
12
2
Z-9
EAST CONCEALMENT SHROUD DETAILS
SCALE: 1/4"=1'-0"
2 0 1 2 4 8
1/4 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROPOSED SLED MOUNT BEHIND
CONCEALMENT SHROUD (TYP)
PROPOSED ANTENNA WITHIN
CONCEALMENT SHROUD (TYP) PROPOSED CONCEALMENT SHROUD
(SHROUD TO BE PAINTED AND TEXTURED
TO MATCH BUILDING) (TYP)
RF TRANSPARENT MATERIAL SPECIFICATIONS
FIBERGLASS REINFORCED PLASTIC (FRP) SHAPES:
1. ALL FRP SHAPES AND PLATE SHALL CONFORM TO STRONGWELL EXTREN 500/525 SERIES.
2. APPLY RESIN ADHESIVE TO ALL FRP MATING SURFACES PRIOR TO BOLTING.
3. STRONGWELL FIBERBOLTS AND NUTS OR EQUAL.
4. ALL CUT EDGES AND HOLES SHALL BE SEALED WITH A RESIN COMPATIBLE WITH THE RESIN
MATRIX USED IN THE STRUCTURAL SHAPE.
5. THE FABRICATOR AND CONTRACTOR SHALL EXERCISE PRECAUTIONS NECESSARY TO
PROTECT THE FIBERGLASS PULTRUDED STRUCTURAL SHAPES FROM ABUSE TO PREVENT
BREAKAGE, NICKS, GOUGES, ETC. DURING FABRICATION, HANDLING, AND INSTALLATION.
6. STURCTURAL SHAPES SHALL BE FABRICATED AND ASSEMBLED AS INDICATED ON THE DESIGN
DRAWINGS.
7. FIBERBOLTS BOLTS AND NUTS SHALL BE TIGHTENED TO AND LOCKED WITH EPOXY AS
FOLLOWS:
1/2" DIAMETER NUTS 8 FT-LBS TORQUE
5/8" DIAMETER NUTS 16 FT-LBS TORQUE
3/4" DIAMETER NUTS 24 FT-LBS TORQUE
FIBERGLASS PANEL NOTES: BY LARSON CAMOFLAGE, LLC
- FABRICATE PANELS TO FIT PER DIMENSIONS SHOWN IN PLAN.
- PANELS TO BE MINIMUM 1/4" THICKNESS.
1. PANELS ARE TO BE FABRICATED IN A CONTIGUOUS LAYUP PER PLANS USING RF
TRANSPARENT MATERIALS.
2. ARCHITECT SHALL SPECIFY ANY REQUIRED FINISHES OR TREATMENTS TO ACHIEVE DESIRED
APPEARANCE.
3. FABRICATOR SHALL USE A GLASS-RESIN RATIO OF 35% + 3%: REINFORCEMENT BY WEIGHT.
4. EACH SKIN SHALL BE FABRICATED WITH GENERAL PERPOSE RESIN OR POLYESTER VINYL
RESIN WHERE REQUIRED FOR FIRE TREATMENT, CHOPPED STRAND MAT.
5. CORNER FLANGES MAY BE FASTENED WITH 5/8" NON-METALLIC THREADED ROD AND NUTS:
STRONGWELL FIBERBOLT STUDS AND NUTS OR EQUIVALENT. A TORQUE WRENCH MUST BE
USED TO TIGHTEN FASTENERS TO A MAXIMUM 16 FT-LBS.
6. FRP PANELS AND SHAPES SHALL BE COATED WITH A FLAT GEL-COAT FINISH TO PROVIDE
ULTRAVIOLET PROTECTION.
7. ALL CUT AND DRILLED EDGES SHALL BE COATED WITH RESIN.
8. FABRICATOR AND INSTALLER SHALL TEST FIT ALL PANELS PRIOR TO FINAL
ASSEMBLY/INSTALLATION TO ASSURE SQUARENESS AND CORNER FITS.
9. CONTACT KEN PUEHL FOR ADDITIONAL INFORMATION AT 520-741-3115.
PROPOSED RRH WITHIN
CONCEALMENT SHROUD (TYP)
PROPOSED OVP WITHIN
CONCEALMENT SHROUD (TYP)
1
Z-9
WEST CONCEALMENT SHROUD DETAILS
SCALE: 1/4"=1'-0"
PER SECTOR)
PROPOSED RRH MOUNTED TO SLED
MOUNT (TYP 3 PER SECTOR)
PROPOSED OVP MOUNTED TO SLED
MOUNT (TYP 1 PER SECTOR)
PROPOSED ANTENNA CONCEALMENT SCREEN
PAINTED TO MATCH EXISTING BUILDING
PROPOSED VERIZON RAD CENTER
41'-5" AGL
TOP OF PROPOSED CONCEALMENT SCREEN
46'-10" AGL
TOP OF EXISTING STRUCTURE
49'-11" AGL
GRADE
0'-0" AGL
GRADE
0'-0" AGL
PER SECTOR)
PROPOSED RRH MOUNTED TO SLED
MOUNT (TYP 3 PER SECTOR)
PROPOSED OVP MOUNTED TO SLED
MOUNT (TYP 1 PER SECTOR)
PROPOSED ANTENNA CONCEALMENT SCREEN
PAINTED TO MATCH EXISTING BUILDING
PROPOSED VERIZON RAD CENTER
41'-5" AGL
TOP OF PROPOSED CONCEALMENT SCREEN
46'-10" AGL
TOP OF EXISTING STRUCTURE
49'-11" AGL
GRADE
0'-0" AGL
GRADE
0'-0" AGL
(TYP 3 PER SECTOR)
PROPOSED RRH MOUNTED TO SLED MOUNT
(TYP 3 PER SECTOR)
PROPOSED OVP MOUNTED ON SLED MOUNT
(TYP 1 PER SECTOR)
PROPOSED ANTENNA CONCEALMENT SCREEN
PROPOSED VERIZON RAD CENTER
42'-0" AGL
TOP OF PROPOSED CONCEALMENT SCREEN
47'-4" AGL
TOP OF EXISTING STRUCTURE
49'-11" AGL
PROPOSED ANTENNA CONCEALMENT SCREEN
GRADE
0'-0" AGL
GRADE
0'-0" AGL
PROPOSED RRH MOUNTED TO SLED MOUNT
(TYP 3 PER SECTOR)
PROPOSED OVP MOUNTED ON SLED MOUNT
(TYP 1 PER SECTOR)
PROPOSED ANTENNA CONCEALMENT SCREEN
TOP OF EXISTING STRUCTURE
49'-11" AGL
PROPOSED VERIZON EQUIPMENT MOUNTED ON
PARAPET ABOVE EXISTING ELEVATOR
PROPOSED ANTENNA CONCEALMENT SCREEN
PROPOSED VERIZON RAD CENTER
42'-0" AGL
TOP OF PROPOSED CONCEALMENT SCREEN
47'-4" AGL
GRADE
0'-0" AGL
GRADE
0'-0" AGL
(CONTINUED)
Z-3
7
N
A
SECTOR
CABLE TABLE
70
AZIMUTH
100'
LENGTH
1
NO. TYPE
NOTES:
1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR
CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS
PRIOR TO ORDERING.
2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS
NOTED OTHERWISE.
3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY
AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR
TO INSTALLING ANY ANTENNAS.
SIZE
6x12 HYBRIFLEX
B 160
C
D
250
340
HYBRIFLEX
HYBRIFLEX
HYBRIFLEX
6x12
6x12
6x12
1
1
1
105'
125'
120'
SECTOR D
VZW ANTENNA AZ= 340°
SECTOR C
VZW ANTENNA AZ= 250°
PROPOSED CABLE TRAY
(TYP)
PROPOSED HYBRID RUN
FROM EQUIPMENT CABINET
TO ROOFTOP OVP'S
PROPOSED ELECTRIC TO BE PULLED
FROM EXISTING ELECTRICAL ROOM IN
BUILDING (LOCATION TBD)
PROPOSED 10'X10' LEASE AREA
BY VERIZON
PROPOSED EQUIPMENT
CABINET (TYP OF 2)
PROPOSED TRAFFIC PAD
(TYP)
PROPOSED ANTENNA
CONCEALMENT SCREEN ON 3 SIDES
(SEE SHEET Z-9)
PROPOSED 8' VERIZON ANTENNA MOUNTED TO
NON-PENETRATING SLED MOUNT BEHIND
CONCEALMENT SCREEN (TYP. 3 PER SECTOR)
PROPOSED OVP MOUNTED TO
NON-PENETRATING SLED MOUNT (TYP 1
PER SECTOR)
PROPOSED FIBER IN CONDUIT ACROSS ROOF TO
CABLE TRAY
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
EQUIPMENT PLAN
Z-2
6
N
PROPOSED ANTENNA
CONCEALMENT SCREEN
SECTOR A
VZW ANTENNA AZ= 70°
SECTOR B
VZW ANTENNA AZ=160°
1
Z-2
SE CORNER EQUIPMENT PLAN
SCALE: 3/16"=1'-0"
0 1 2 4 8
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
3/16 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
1
PROPOSED 8' VERIZON ANTENNA MOUNTED TO
NON-PENETRATING SLED MOUNT BEHIND
CONCEALMENT SCREEN (TYP. 3 PER SECTOR)
PROPOSED OVP MOUNTED TO
NON-PENETRATING SLED MOUNT (TYP 1
PER SECTOR)
(2) PROPOSED NON-PENETRATING
SLED MOUNT
PROPOSED CABLE TRAY
PROPOSED TRAFFIC PAD
PROPOSED RRH (TYP 4 PER SECTOR)
NOTE:
NO WIRELESS TELECOMMUNICATION FACILITY OR
EQUIPMENT OWNER OR LESSEE OR EMPLOYEE
THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO
EXCLUDE ANY OTHER WIRELESS
TELECOMMUNICATION PROVIDER FROM USING THIS
BUILDING, STRUCTURE OR LOCATION.
GAS GAS GAS GAS GAS
OE OE
UT UT
X X X X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD SD SD SD
E E E
UE UE UE
OT OT OT
EV
D
O O O O
U/G U/G
OHW OHW
STORM SEWER
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
PROPOSED VERIZON ANTENNA MOUNTED TO BACK
OF PARAPET WALL BEHIND CONCEALMENT
SCREEN (TYP. 3 PER SECTOR)
PROPOSED ELECTRIC TO BE PULLED
FROM EXISTING ELECTRICAL ROOM IN
BUILDING (LOCATION TBD)
PROPOSED ANTENNA CONCEALMENT SCREEN ON 3 SIDES
(SEE SHEET Z-9)
PROPOSED OVP MOUNTED TO BACK OF
PARAPET WALL (TYP 1 PER SECTOR)
PROPOSED RRH MOUNTED TO BASE OF ANTENNA
MOUNT PIPE (TYP 3 PER SECTOR)
PROPOSED CABLE TRAY
(TYP)
PROPOSED 10'X10' LEASE AREA
BY VERIZON
PROPOSED EQUIPMENT
CABINET (TYP OF 2)
PROPOSED 8' VERIZON ANTENNA MOUNTED TO
NON-PENETRATING SLED MOUNT BEHIND
CONCEALMENT SCREEN (TYP. 3 PER SECTOR)
PROPOSED ANTENNA CONCEALMENT SCREEN
(SEE SHEET Z-9)
PROPOSED OVP MOUNTED TO NON-PENETRATING
SLED MOUNT (TYP 1 PER SECTOR)
PROPOSED RRH MOUNTED TO NON-PENETRATING
SLED MOUNT (TYP 3 PER SECTOR)
PROPOSED FIBER VAULT
PROPOSED 10' WIDE UTILITY AND
ACCESS EASEMENT
PROPOSED EXTERIOR FIBER CONDUIT,
PAINTED TO MATCH BUILDING EXTERIOR
PROPOSED FIBER RUN
(UNDERGROUND TO SIDE OF BUILDING)
EXISTING ACCESS HACTH
PROPOSED FIBER ACROSS ROOF
IN CONDUIT TO CABLE TRAY
PROPOSED TRAFFIC PAD
(TYP)
(2) PROPOSED NON-PENETRATING
SLED MOUNT.
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-LEASE
AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
2
PH-2
2
PH-3
2
PH-1
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 EQUIPMENT PLAN
Z-4 ELEVATIONS
PROJECT DESCRIPTION
1. INSTALL (12) NEW 8' ANTENNAS AND (12) RRHS
2. INSTALL (2) NEW ANTENNA CONCEALMENT SCREENS
3. INSTALL CABLE TRAYS TO RUN HYBRIFLEX TO PROPOSED EQUIPMENT
4. INSTALL (2) NEW EQUIPMENT CABINETS
5. INSTALL (4) NEW OVPS
6. INSTALL (2) NON-PENETRATING SLED MOUNTS FOR PROPOSED EQUIPMENT.
7. INSTALL NEW FIBER VAULT AND RUN FIBER THROUGH EXTERIOR CONDUIT TO PROPOSED
EQUIPMENT.
8. INSTALL NEW TRAFFIC MATS ON THE ROOF
9. RUN NEW POWER TO PROPOSED EQUIPMENT THROUGH EXISTING ELECTRICAL ROOM.
10. INSTALL NEW COAX CABLES.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
JURISDICTION: CITY OF FT. COLLINS
ZONING: HIGH DENSITY MIXED-USE
NEIGHBORHOOD DISTRICT
APN: 9714321001
PARCEL SIZE: 62,564 S.F.
ELEVATION: 5028.7' (NAVD 88)
STRUCTURE TYPE: EXISTING STRUCTURE
STRUCTURE HEIGHT: 49'-11"± AGL
ANTENNA RAD CENTER: SECTOR A & B: 42'-0"± AGL
SECTOR C & D: 41'-5"± AGL
APPLICANT: VERIZON WIRELESS REAL ESTATE
APPLICANT CONTACT: BRANDON KISER
9656 S. PROSPERITY RD.
WEST JORDAN, UT 84088
PH: 801-260-8700
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: 720 279-8973
REVISION SCHEDULE
REV DATE BY DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 12
SITE NAME:
FTC RAMS CROSSING
SITE ADDRESS:
808 W PROSPECT RD
FORT COLLINS, CO
80525
JURISDICTION:
CITY OF FORT COLLINS
AERO PROJECT # : 097-17-0093
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
A 06-16-17 EGW ZONING
B 07-17-17 KRC FINAL ZONING
C 01-24-18 GAC REVISED ZONING
SHEET NUMBER:
D 03-07-18 GAC FINAL ZONING
LEGAL DESCRIPTION
LOT 1, THE SLAB PROPERTY, COUNTY OF LARIMER, STATE OF COLORADO
Z-5
PH-1 PHOTOSIMULATION VIEWS
PH-2 PHOTOSIMULATION VIEWS
Z-3 EQUIPMENT PLAN (CONTINUED)
PH-3 PHOTOSIMULATION VIEWS
Z-6
Z-7
ELEVATIONS (CONTINUED)
ELEVATIONS (CONTINUED)
Z-8
ELEVATIONS (CONTINUED)
CONCEALMENT SHROUD DETAILS
PLANNING CERTIFICATION
APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF
THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF
___________________________, A.D.,20____.
___________________________
DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES
OWNERSHIP CERTIFICATION
_________________________________
BY _________________________________
STATE OF COLORADO )
) SS.
COUNTY OF LARIMER )
THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF
___________________________, A.D.,20____,
BY __________________________.
WITNESS MY HAND AND OFFICIAL SEAL.
MY COMMISSION EXPIRES:_______________________
______________________________
NOTARY PUBLIC
SITE PLAN CERTIFICATION