Loading...
HomeMy WebLinkAboutFTC MO JEAUX, WTE (VERIZON) - BASIC DEVELOPMENT REVIEW - BDR180026 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSFTC MO JEAUX SC 1409 W ELIZABETH ST FORT COLLINS, COLORADO 80521 NEW ROOFTOP MACRO ZONING DRAWINGS VICINITY MAP PROJECT AREA SITE DIRECTIONS DEPART 3131 S VAUGHN WAY, AURORA, CO 80014: HEAD SOUTH TOWARD S VAUGHN WAY. MERGE ONTO I-225 N. TAKE EXIT 12A TO MERGE ONTO I-70 W. KEEP RIGHT AT THE FORK TO CONTINUE ON I-270 W. TAKE EXIT 0 TO MERGE ONTO I-25 N TOWARDS FORT COLLINS. TAKE EXIT 269B TO MERGE ONTO CO-14 W/E MULBERRY ST TOWARD FORT COLLINS. MERGE ONTO CO-14 W/E MULBERRY ST. CONTINUE STRAIGHT ONTO W MULBERRY ST. TURN LEFT ONTO CITY PARK AVE. TURN RIGHT ONTO W ELIZABETH ST. DESTINATION WILL BE ON THE LEFT IN 328 FT. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 66211 PHONE: 913-344-2030 1409 ELIZEBETH LLC CONTACT: PHILIP SCHUMAN PHONE: 970-219-9965 3977 CAMINO RANCHERO CAMARILLO, CA 93012 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 970-646-1283 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION LRK CONSULTING 1196 GRANT STREET, UNIT 313 DENVER, CO 80203 CONTACT: RYAN SAGAR PHONE: 219-477-0099 VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/ LOCAL AMENDMENTS) NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING PHOTOSIMULATION VIEWS PH-1 2 4 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING SOUTH) N.T.S. 3 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTH) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING SOUTHWEST) N.T.S. 2 PH-1 PHOTOSIMULATION VIEW (ATFER, LOOKING SOUTHWEST) N.T.S. REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING PHOTOSIMULATION VIEWS PH-2 3 1 PH-2 PHOTOSIMULATION VIEW (BEFORE, LOOKING EAST) N.T.S. 2 PH-2 PHOTOSIMULATION VIEW (ATFER, LOOKING EAST) N.T.S. D S Y WV WV WM S WV WM ET GM SS SS SS SS SS SS SS SS SS SS SS SS SS SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD TV TV TV TV TV TV TV UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE UE SD SD S SD SD SD SD SD SD D SD SD SD SD SD SD SD SD SD SD SD SD SD X X X X X X X X X X X X X X X X X X X X X X F F F F F F F F F F F F EXISTING 10'-0" DRAINAGE EASEMENT EXISTING 12'-0" UTILITY EASEMENT EXISTING 10'-0" UTILITY EASEMENT PROPOSED 20'-0" EAE 1 Z-1 SITE PLAN SCALE: 1"=30'-0" EXISTING BUILDING 1 inch = 30ft. ( IN FEET ) WM F F F F F F F F F F F F F F F F RD RD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD F F F F F F F F F F F F E RD RD 1'-6" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-2 EQUIPMENT PLAN SCALE: 3/32"=1'-0" REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 33'-0" 36'-7" 39'-0" 49'-0" 48'-0" 44'-0" 36'-7" 39'-0" 33'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 2 Z-3 PROPOSED EAST ELEVATION SCALE: 1/16"=1'-0" 1 Z-3 EXISTING EAST ELEVATION SCALE: 1/16"=1'-0" REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING 98'-0" THIS DRAWING DOES NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY. ALL CONSTRUCTION MUST BE DONE IN COMPLIANCE WITH THE OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 AND ALL RULES AND REGULATIONS PROTECT YOURSELF, GIVE THREE WORKING DAYS NOTICE THERE TO APPURTENANT. Know what's below. Call before you dig. 1 Z-4 PROPOSED LINE OF SIGHT ELEVATION SCALE: N.T.S. REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING LINE OF SIGHT ELEVATIONS Z-4 7 PROPOSED LINE OF SIGHT FROM 5'8" IN THE MIDDLE OF THE SIDEWALK ACROSS W ELIZABETH AVENUE L.O.S. NOTE: THIS ELEVATION IS NOT DRAWN TO SCALE. IT IS REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING MATERIAL REFERENCES Z-5 8 1 Z-5 ANTENNA SCREEN COLOR SAMPLE N.T.S. MAIN FIBERGLASS SCREEN: SMOOTH STUCCO PAINTED TO MATCH LIGHT TAN OF EXISTING BUILDING WALLS FASCIA TRIM OF NEW SCREEN TO MATCH LIGHT SILVER COLOR OF EXISTING GUTTER/BUILDING TRIM M LOAD CENTER PANEL CIRCUIT AND LOAD SCHEDULE SERVICE: DESIGNATION: LOCATION: TOTAL KVA CONTINUOUS x 1.25 TOTAL KVA NON-CONTINUOUS TOTAL KVA TOTAL AMPS 33.68 0 33.68 140.31 REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING ONE-LINE DIAGRAM & PANEL SCHEDULE Z-6 9 1 Z-6 ONE-LINE DIAGRAM N.T.S. PROPOSED 200A LOAD CENTER EXISTING 120/208 V 3Ø TRANSFORMER (FAULT = TBD) PROPOSED 3" PVC CONDUIT WITH (4) 3/0 CU CONDUCTORS PROPOSED 200A LEVER-TYPE DISCONNECT (FAULT = TBD) PROPOSED 200A METER PROPOSED 200A LEVER-TYPE DISCONNECT PROPOSED 3" EMT CONDUIT WITH (4) 3/0 CU CONDUCTORS & (1) #6 CU GROUND 2 Z-6 PANEL SCHEDULE N.T.S. A VISUAL REPRESENTATION OF HOW THE SITE WOULD APPEAR TO A 5' 8" PERSON STANDING ON THE SIDEWALK ACROSS WEST ELIZABETH AVE PROPOSED VERIZON EQUIPMENT MOUNTED TO BACK OF PARAPET BEHIND CONCEALMENT WALL WEST ELIZABETH AVENUE 2 Z-4 PROPOSED PERSPECTIVE ELEVATION SCALE: N.T.S. PROPOSED ANTENNA CONCEALMENT SCREEN (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) PROPOSED ANTENNA CONCEALMENT SCREEN (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) PROPOSED VERIZON ANTENNA MOUNTED TO BACK OF PARAPET WALL (4 PER SECTOR, 16 TOTAL) G 05-14-18 RPH REVISED FINAL ZONING 1/16 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 8 0 4 8 16 32 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) ELEVATIONS Z-3 6 PROPOSED VERIZON ANTENNA MOUNTED TO BACK OF PARAPET WALL (4 PER SECTOR, 16 TOTAL) TOP OF PARAPET 36'-7" AGL TOP OF ROOF 33'-0" AGL PROPOSED VERIZON RRH MOUNTED TO BOTTOM OF ANTENNA MOUNT (4 PER SECTOR, 16 TOTAL) TOP OF PROPOSED VERIZON ANTENNA 48'-0" AGL PROPOSED VERIZON RAD CENTER 44'-0" AGL GRADE 0'-0"± AGL PROPOSED OVP MOUNTED TO BACK OF PARAPET WALL (1 PER SECTOR, 4 TOTAL) TOP OF PROPOSED ANTENNA CONCEALMENT 49'-0" AGL PROPOSED FIBER RUN UP SIDE OF BUILDING IN CHASE (PAINT TO MATCH EXISTING DOWNSPOUTS) PROPOSED ANTENNA CONCEALMENT SCREEN (TYP) (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) GRADE 0'-0"± AGL TOP OF STURCTURE 39'-0" AGL TOP OF STURCTURE 39'-0" AGL TOP OF PARAPET 36'-7" AGL TOP OF ROOF 33'-0" AGL SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING 3/32 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE 0 2 4 8 12 16 20 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 EQUIPMENT PLAN Z-2 4 N PROPOSED CHASE TO ROOFTOP PAINTED TO MATCH EXISTING DOWNSPOUTS PROPOSED VERIZON ANTENNA MOUNTED TO BACK OF PARAPET WALL (4 PER SECTOR, 16 TOTAL) PROPOSED ANTENNA CONCEALMENT WALL (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) PROPOSED HYBRID RUN FROM EQUIPMENT CABINET TO ROOFTOP OVP'S PROPOSED CABLE TRAY PROPOSED VERIZON RRH MOUNTED TO BOTTOM OF ANTENNA MOUNT (4 PER SECTOR, 16 TOTAL) SECTOR D VZW ANTENNA AZ= 330° SECTOR A VZW ANTENNA AZ= 60° SECTOR B VZW ANTENNA AZ=150° SECTOR C VZW ANTENNA AZ= 240° PROPOSED OVP MOUNTED TO BACK OF PARAPET WALL (1 PER SECTOR, 4 TOTAL) PROPOSED EQUIPMENT CABINET (TYP OF 2) PROPOSED ELECTRIC TO BE PULLED FROM EXISTING ELECTRIC ROOM IN BUILDING PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 04/19/17. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET EIA/TIA-222-G AS PER IBC 2012 REQUIREMENTS. 15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. A SECTOR CABLE TABLE 60° AZIMUTH 210' LENGTH 1 NO. TYPE NOTES: 1. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING. 2. ALL AZIMUTHS SHOWN ARE RELATIVE TO TRUE NORTH, UNLESS NOTED OTHERWISE. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY AZIMUTHS DEPICTED HEREIN WITH THE RF DEPARTMENT PRIOR TO INSTALLING ANY ANTENNAS. SIZE 6x12 HYBRIFLEX B 150° C D 240° 330° HYBRIFLEX HYBRIFLEX HYBRIFLEX 6x12 6x12 6x12 1 1 1 25' 15' 200' 2 Z-3 2 Z-5 GRAPHIC SCALE 15 0 7.5 15 30 60 (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING SITE PLAN Z-1 4 W ELIZEBETH ST PROPOSED 2'x3' FIBER VAULT PROPOSED VERIZON ANTENNA MOUNTED TO BACK OF PARAPET WALL BEHIND SCREEN (TYP 4 PER SECTOR, 16 TOTAL) PROPOSED EQUIPMENT CABINET (TYP OF 2) PROPOSED ANTENNA CONCEALMENT WALL (PAINT TO MATCH PRIMARY BUILDING COLOR AND NEW TRIM) PROPOSED FIBER RUN FROM FIBER VAULT TO EQUIPMENT SITE PROPOSED OVP MOUNTED TO BACK OF PARAPET WALL (TYP 1 PER SECTOR, 4 TOTAL) PROPOSED RRH MOUNTED TO BASE OF ANTENNA MOUNT POST (TYP 4 PER SECTOR, 16 TOTAL) PROPOSED FIBER ROUTED UP SIDE OF BUILDING IN CHASE TO MATCH EXISTING DOWNSPOUT EXISTING ELEVATOR SHAFT EXISTING ACCESS HATCH 2 Z-3 2 Z-5 PROPOSED ELECTRIC TO BE PULLED FROM EXISTING ELECTRIC ROOM IN BUILDING PROPOSED 10' WIDE UTILITY EASEMENT PROPOSED 10' WIDE ACCESS EASEMENT VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING LEGEND W SS F GAS GAS OE UT X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD E UE OT EV D O O U/G OHW STORM DRAIN UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 04/19/17. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO NOISE, SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. 9. NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THIS BUILDING, STRUCTURE OR LOCATION PROPOSED FIBER IN 2" SCH 40 PVC CONDUIT W/ 3-CELL PLENUM MAXCELL INNERDUCT TO MMP IN R.O.W. N PROPOSED 20'-0" WIDE EMERGENCY ACCESS EASEMENT EXISTING EMERGENCY ACCESS EASEMENT (REFERENCE PROJECT # R16-045 "HUB ON CAMPUS FORT COLLINS" BY RIPLEY DESIGN INC., DATED 11-06-17) ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-3 EQUIPMENT PLAN PROJECT DESCRIPTION 1. INSTALL (2) NEW EQUIPMENT CABINETS ON ROOF. 2. INSTALL (16) NEW ANTENNAS ON BACK OF PARAPET WALL. 3. INSTALL (16) NEW REMOTE RADIO HEADS ON PARAPET WALL. 4. INSTALL NEW FIBER VAULT FOR PROPOSED FIBER RUN. 5. RUN NEW FIBER AND POWER TO PROPOSED EQUIPMENT. 6. INSTALL (4) HYBRID CABLES. 7. INSTALL (4) OVPS AT ROOF LEVEL. 8. RF TRANSPARENT SCREEN WALLS. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FT. COLLINS ZONING: COMMUNITY COMMERCIAL DISTRICT APN: 9715431004 PARCEL SIZE: 20,474 S.F. ELEVATION: 5043' (NAVD 88) STRUCTURE TYPE: BUILDING STRUCTURE HEIGHT: 39'-0"± (TOP OF STRUCTURE) ANTENNA RAD CENTER: 44'-0" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: JENNIFER SCHNEIDER 10740 NALL AVENUE, SUITE 400 OVERLAND PARK, KS 662211 PH: 913-344-2030 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: 720 279-8973 REVISION SCHEDULE REV A DATE 06-07-17 BY KRC ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 9 SITE NAME: FTC MO JEAUX SC SITE ADDRESS: 1409 W ELIZEBETH ST FORT COLLINS, CO 80521 JURISDICTION: CITY OF FT COLLINS AERO PROJECT #: 097-17-0092 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 B 06-23-17 KRC FINAL ZONING C 09-07-17 RPH REVISED FINAL ZONING 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: D 11-03-17 RPH REVISED FINAL ZONING E 02-06-18 GAC REVISED FINAL ZONING F 05-03-18 RPH REVISED FINAL ZONING G 05-14-18 RPH REVISED FINAL ZONING Z-4 ELEVATIONS LINE OF SITE ELEVATIONS Z-2 LEGAL DESCRIPTION LOT 2, FAIRVIEW SHOPPING CENTER FILING FOUR, COUNTY OF LARIMER, STATE OF COLORADO, CITY OF FORT COLLINS PH-1 PHOTOSIMULATION VIEWS Z-5 MATERIAL REFERENCES PHOTOSIM LOCATION #1 PHOTOSIM LOCATION #2 PH-2 PHOTOSIMULATION VIEWS PHOTOSIM LOCATION #3 Z-6 ONE-LINE DIAGRAM & PANEL SCHEDULE PLANNING CERTIFICATION APPROVED BY THE DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICE OF THE CITY OF FORT COLLINS, COLORADO ON THIS _________ DAY OF ___________________________, A.D.,20____. ___________________________ DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES OWNERSHIP CERTIFICATION _________________________________ BY _________________________________ STATE OF COLORADO ) ) SS. COUNTY OF LARIMER ) THE FOREGOING INSTRUMENT WAS ACKNOWLEDGED BEFORE ME THIS _________ DAY OF ___________________________, A.D.,20____, BY __________________________. WITNESS MY HAND AND OFFICIAL SEAL. MY COMMISSION EXPIRES:_______________________ ______________________________ NOTARY PUBLIC SITE PLAN CERTIFICATION