HomeMy WebLinkAboutFTC BIG CITY, WIRELESS TELECOMMUNICATIONS EQUIPMENT - BASIC DEVELOPMENT REVIEW - BDR180022 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSFTC BIG CITY SC7
505 S. MASON ST.
FORT COLLINS, CO 80521
SMALL CELL NSB
ZONING DRAWINGS
PROJECT
AREA
SITE DIRECTIONS
FROM 3131 SOUTH VAUGHN WAY:
GET ON I-225 N FROM SOUTH URSULA ST, S.VAUGHN WAY AND E. ILIFF AVE. FROM I-225 N TAKE
E-470 N TO I-25 N. TAKE I-25 N TO CO-14W/ E MULBERRY ST IN LARIMER COUNTY. TAKE EXIT 269B
FROM I-25 N. FOLLOW E. MULBERRY ST TO MASON ST IN FORT COLLINS.
FORT COLLINS, COLORADO
CLIENT
PROPERTY OWNER
VERIZON WIRELESS REAL ESTATE
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: BRANDON KISER
PHONE: 801-260-8700
RHI 1 MAX FLATS LLC
CONTACT: TAMMY PETERSON
PHONE: 970-484-3454
5200 W 20TH ST
GREELEY, CO 80634
AERO SOLUTIONS, LLC
5555 CENTRAL AVE #100
BOULDER, CO 80301
CONTACT: MATT FLECK
PHONE: 720-279-8973
ENGINEER
CONSTRUCTION MANAGER
SITE ACQUISITION
CENTERLINE SOLUTIONS
16035 TABLE MOUNTAIN PARKWAY
GOLDEN, CO 80403
CONTACT: JEN DANIELS
PHONE: 303-550-4820
RF ENGINEER
PROJECT DATA
CODE ANALYSIS
IBC 2015 (W/LOCAL AMENDMENTS
NEC 2017
NFPA-1 (2006)
U - UTILITY
IIB
BUILDING CODE:
ELECTRICAL CODE:
FIRE SAFETY CODE:
USE GROUP:
CONSTRUCTION TYPE:
SHEET INDEX
T-1 TITLE SHEET
Z-1 SITE PLAN
Z-2 ENLARGED SITE PLAN
Z-3
PROJECT DESCRIPTION
1. INSTALL NEW MULTI-USE POLE.
2. INSTALL (2) RRH'S AND ASSOCIATED EQUIPMENT WITHIN NEW MULTI-USE POLE.
3. INSTALL PROPOSED SMALL CELL ANTENNA ON NEW MULTI-USE POLE.
REVISION SCHEDULE
REV
A
DATE
10-06-17
BY
GAC 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC BIG CITY SC7
SITE ADDRESS:
505 S. MASON ST.
FORT COLLINS, CO 80521
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0119
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
SHEET NUMBER:
B 11-17-17 LCW REVISED ZONING DRAWINGS
C 01-24-18 LCW REVISED ZONING DRAWINGS
D 05-02-18 JID REVISED ZONING DRAWINGS
PHOTOSIMULATION
VIEWS
PH-1
2
2
PH-1
PHOTOSIMULATION VIEW (AFTER, LOOKING WEST)
N.T.S.
1
PH-1
PHOTOSIMULATION VIEW (BEFORE, LOOKING WEST)
N.T.S.
1'-6"
45'-0"
10'-0"
10'-0"
45'-0"
REVISION SCHEDULE
REV
A
DATE
10-06-17
BY
GAC 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC BIG CITY SC7
SITE ADDRESS:
505 S. MASON ST.
FORT COLLINS, CO 80521
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0119
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
SHEET NUMBER:
B 11-17-17 LCW REVISED ZONING DRAWINGS
C 01-24-18 LCW REVISED ZONING DRAWINGS
D 05-02-18 JID REVISED ZONING DRAWINGS
LINE DRAWING
LD-1
3
1
LD-1
MULTIUSE POLE LINE DRAWING
N.T.S.
ALL ASSOCIATED SERVICE
EQUIPMENT WITHIN POLE BASE
PROPOSED QUASI
OMNI ANTENNA
MOUNTED TO POLE
PROPOSED LED LIGHT
(1) PROPOSED MULTI-USE
POLE WITH CANISTER
ANTENNA MOUNTED ON TOP
S S
SS SS
O O O
O O O O O O O O O O O
ET
AC
E E E E E E E
E E
EXISTING 20'-0" UTILITY EASEMENT
EXISTING
UTILITY EASEMENT
(WIDTH VARIES)
REVISION SCHEDULE
REV
A
DATE
10-06-17
BY
GAC 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC BIG CITY SC7
SITE ADDRESS:
505 S. MASON ST.
FORT COLLINS, CO 80521
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0119
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
SHEET NUMBER:
B 11-17-17 LCW REVISED ZONING DRAWINGS
C 01-24-18 LCW REVISED ZONING DRAWINGS
D 05-02-18 JID REVISED ZONING DRAWINGS
1
Z-4
Z-2
1
N
GENERAL NOTES:
1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN
ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED
09/21/17.
2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN
STORMWATER RUNOFF. THEREFORE, NO DRAINAGE
STRUCTURES ARE PROPOSED.
3. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION.
(THERE IS NO HANDICAP ACCESS REQUIRED).
5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE
WATER OR SANITARY SERVICE.
SS SS SS SS SS SS SS SS
O O O O O O O O
E E E E E
8'-7"
14'-7"
REVISION SCHEDULE
REV
A
DATE
10-06-17
BY
GAC 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC BIG CITY SC7
SITE ADDRESS:
505 S. MASON ST.
FORT COLLINS, CO 80521
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0119
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
SHEET NUMBER:
B 11-17-17 LCW REVISED ZONING DRAWINGS
C 01-24-18 LCW REVISED ZONING DRAWINGS
D 05-02-18 JID REVISED ZONING DRAWINGS
1
Z-4
N
ENLARGED
SITE PLAN
Z-2
5
1
Z-2
ENLARGED SITE PLAN
SCALE: 1"=10'-0"
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
EXISTING
BUILDING
EXISTING CEDAR
FENCE
5 0 2.5 5 10 20
1 inch = 10 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
8'-0"
REVISION SCHEDULE
REV
A
DATE
10-06-17
BY
GAC 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC BIG CITY SC7
SITE ADDRESS:
505 S. MASON ST.
FORT COLLINS, CO 80521
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0119
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
SHEET NUMBER:
B 11-17-17 LCW REVISED ZONING DRAWINGS
C 01-24-18 LCW REVISED ZONING DRAWINGS
D 05-02-18 JID REVISED ZONING DRAWINGS
N
EXISTING
ELEVATION
Z-3
6
1
Z-3
EXISTING ELEVATION
SCALE: 1/8"=1'-0"
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
4 0 2 4 8 16
1/8 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
DRIVEWAY
EXISTING 55'-0" TALL
BUILDING
EXISTING SIGN (TYP)
EXISTING
LANDSCAPING
TOP OF FENCE
8'-0" AGL
EXISTING CEDAR
45'-0"
43'-4"
10'-0"
1'-6"
REVISION SCHEDULE
REV
A
DATE
10-06-17
BY
GAC 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC BIG CITY SC7
SITE ADDRESS:
505 S. MASON ST.
FORT COLLINS, CO 80521
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0119
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
SHEET NUMBER:
B 11-17-17 LCW REVISED ZONING DRAWINGS
C 01-24-18 LCW REVISED ZONING DRAWINGS
D 05-02-18 JID REVISED ZONING DRAWINGS
PROPOSED
ELEVATION
Z-4
7
1
Z-4
PROPOSED ELEVATION
SCALE: 1/8"=1'-0"
4 0 2 4 8 16
1/8 inch = 1 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PROPOSED TOP OF ANTENNA
45'-0" AGL
PROPOSED VERIZON RAD CENTER
43'-4" AGL
TOP OF PROPOSED LED LIGHT
10'-0" AGL
GRADE
4997' (NAVD 88)
EXISTING 55'-0" TALL
BUILDING
EXISTING SIGN (TYP)
S S
SS SS
O O O
O O O O O O O O O O O
ET
AC
20'-0"
S
SS SS
O O O
O O O O O O O O O O O
ET
AC
20'-0"
REVISION SCHEDULE
REV
A
DATE
10-06-17
BY
GAC 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC BIG CITY SC7
SITE ADDRESS:
505 S. MASON ST.
FORT COLLINS, CO 80521
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0119
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
SHEET NUMBER:
B 11-17-17 LCW REVISED ZONING DRAWINGS
C 01-24-18 LCW REVISED ZONING DRAWINGS
D 05-02-18 JID REVISED ZONING DRAWINGS
N
20 0 10 20 40 80
1 inch = 40 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
PHOTOMETRIC
PLAN
PM-1
8
1
PM-1
PHOTOMETRIC PLAN EXISTING
SCALE: 1"=40'-0"
EXISTING
BUILDING
MULBERRY ST
MASON ST
EXISTING CURB (TYP)
EXISTING SIDEWALK (TYP)
EXISTING CMU
WALL (TYP)
EXISTING
BUILDING
MULBERRY ST
MASON ST
EXISTING CURB (TYP)
EXISTING SIDEWALK (TYP)
(1) PROPOSED MULTI-USE
POLE WITH CANISTER
ANTENNA MOUNTED ON TOP
EXISTING CMU WALL (TYP)
EXISTING WALL
MOUNTED LIGHT
FIXTURE (TYP)
EXISTING LED LIGHT POLE
EXISTING POLE
MOUNTED LIGHT
EXISTING
FENCE (TYP)
20'-0" PROPERTY
LINE OFFSET
EXISTING WALL
MOUNTED LIGHT
FIXTURE (TYP)
EXISTING LED LIGHT POLE
EXISTING POLE
MOUNTED LIGHT
EXISTING
FENCE (TYP)
20'-0" PROPERTY
LINE OFFSET
20 0 10 20 40 80
1 inch = 40 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
2
PM-1
PHOTOMETRIC PLAN PROPOSED
SCALE: 1"=40'-0"
EXISTING
LANDSCAPING
EXISTING CEDAR
FENCE
PROPOSED MULTI-USE POLE
(FINAL DESIGN TBD)
(PAINTED GRAY TO MATCH
EXISTING LIGHT POLES)
PROPOSED VERIZON
ANTENNA MOUNTED ON
MULTI-USE POLE
NOTE:
1. PROPOSED LIGHTING TO CONFORM TO SECTION 3.2.4 OF THE FORT
COLLINS LAND USE CODE
2. PER CITY FLOOD RISK MAP DATED 1/2/2018 PROVIDED BY THE CITY
OF FORT COLLINS, THE EXISTING FLOODPLAIN AT THE TOWER
LOCATION IS 4,996.663' (CONVERTED TO NAVD 88)
FENCE
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES
ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES,
UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY
FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES.
3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN
WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE
SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR
OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE
THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT
OF THESE DRAWINGS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL
EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING
CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE
CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY.
5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING
ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE
THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO
SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE
CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN
ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 09/21/17.
8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE
IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES
ARE PROPOSED.
9. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY.
10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION
(THERE IS NO HANDICAP ACCESS REQUIRED).
11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE
WATER OR SANITARY SERVICE.
12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE
METER.
13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH
WITH RF ENGINEERING PRIOR TO INSTALLATION.
14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER
IBC 2015 REQUIREMENTS.
15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED
STEEL.
16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL
UTILITIES PRIOR TO EXCAVATING.
17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST
LOCATE IT AND CONTACT OWNERS REPRESENTATIVE.
18. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION
MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING
PROPOSED 10'-0" WIDE
ACCESS EASEMENT
PROPOSED 10'x10'
LEASE AREA
PROPOSED 5'-0" WIDE
UTILITY EASEMENT
PROPOSED UNDERGROUND
FIBER RUN TO EQUIPMENT
(UNDERGROUND MEET POINT
TO BE DETERMINED)
PROPOSED 4'x4'
FUTURE LEASE AREA
(1) PROPOSED MULTI-USE
POLE WITH CANISTER
ANTENNA MOUNTED ON TOP
EXISTING CMU WALL
PROPOSED 5'-0" WIDE
UTILITY EASEMENT
PROPOSED POWER TO BE PULLED
FROM EXISTING TRANSFORMER
MASON ST
ANTENNA
DESIGNATION
CABLE TABLE
±55'
LENGTH
2
NO. TYPE
CONDUIT
WITH 3-CELL PLENUM
FIBER IN CONDUIT
N/A
FIBER RUN ±10' 1 2"
1/2" COAX
SIZE
MAXCELL INNERDUCT
6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM
OF 1988 (NAVD 1988).
7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET
SIGNS OF ANY TYPE.
8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR
STORAGE OR ANY SOLID WASTE RECEPTACLES.
VERIZON COLOR STANDARDS
GRAY-EXISTING
EASEMENT
ORANGE-FIBER
TAN-ANTENNAS
RED-PENETRATIONS
UMBER-NEW WORK
UTILITY EASEMENT
BLUE #1-HYBRID
CABLES/COAX
BLUE GRAY#1-
ACCESS/UTILITY
PURPLE #1-
LEASE AREA
BLUE #2-RRHS GRAY-WALL HATCH
GREEN-DC POWER GREY-EXISTING
LEGEND
W
SS
F
GAS GAS
OE
UT
X X
S
WV
T
WM
ICV
E
WATER LINE
SANITARY SEWER
GAS LINE
FIBER LINE
OH ELECTRIC
UG TELCO
FENCE CLF
RIGHT OF WAY
WATER METER
WATER VALVE
IRRIGATION VALVE
SAN SEWER MH
TELCO MAN HOLE
LIGHT POLE
ELEC PULL BOX
SD SD
E
UE
OT
EV
D
O O
U/G
OHW
STORM DRAIN
UG ELECTRIC
ELECTRIC
OH TELCO
PROPERTY LINE
FENCE IRON
UG UTILITIES
OH UTILITIES
SIGNAGE
CATCH BASIN
STORM MANHOLE
POWER POLE
TRAFFIC SIGNAL
ELECTRIC VAULT
ELECTRIC CABINET
ELECTRIC EQUIP EQ ELECTRICAL XFMR ET
20 0 10 20 40 80
1 inch = 40 ft.
( IN FEET )
GRAPHIC SCALE
(SCALE BASED ON 11"x17" SHEETS ONLY)
(DO NOT USE SCALE ON OTHER SIZED DRAWINGS)
SITE PLAN
Z-1
4
1
Z-1
SITE PLAN
SCALE: 1"=40'-0"
UTILITY NOTIFICATION CENTER
Know what's below.
Call before you dig.
TOLL FREE 1800-227-2600
EXISTING
BUILDING
MULBERRY ST
MASON ST
EXISTING 20'
ALLEY
EXISTING CURB (TYP)
EXISTING SIDEWALK (TYP)
PROPOSED 10'-0" WIDE
ACCESS EASEMENT
PROPOSED 10'x10'
LEASE AREA
PROPOSED 5'-0" WIDE
UTILITY EASEMENT
PROPOSED UNDERGROUND
FIBER RUN TO EQUIPMENT
(UNDERGROUND MEET POINT
TO BE DETERMINED)
PROPOSED 5'-0" WIDE
UTILITY EASEMENT
PROPOSED POWER TO BE PULLED
FROM EXISTING TRANSFORMER
PROPOSED 4'x4'
FUTURE LEASE AREA
(1) PROPOSED MULTI-USE
POLE WITH CANISTER
ANTENNA MOUNTED ON TOP
EXISTING CMU WALL (TYP)
NOTE:
NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT
OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO
EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS
TELECOMMUNICATION PROVIDER FROM USING THE SAME BUILDING,
STRUCTURE OR LOCATION. WIRELESS TELECOMMUNICATION
FACILITY OR EQUIPMENT OWNERS OR LESSEES OR EMPLOYEES
THEREOF, AND APPLICANTS FOR THE APPROVAL OF PLANS FOR
THE INSTALLATION OF SUCH FACILITIES OR EQUIPMENT, SHALL
COOPERATE IN GOOD FAITH TO ACHIEVE CO-LOCATION OF
WIRELESS TELECOMMUNICATION FACILITIES AND EQUIPMENT
4. INSTALL NEW UNDERGROUND FIBER AND POWER TO PROPOSED EQUIPMENT.
5. INSTALL COAX FROM EQUIPMENT TO ANTENNA.
VERIZON (RF): DATE:
DATE:
DATE:
DATE:
VERIZON (CONST.):
VERIZON (RE):
LANDLORD:
APPROVALS
TITLE SHEET
T-1
1
JURISDICTION: CITY OF FORT COLLINS
ZONING: DOWNTOWN DISTRICT
APN: 9714123001
PARCEL SIZE: 0.68 AC
ELEVATION: 4,997' (NAVD 88)
STRUCTURE TYPE: NEW MULTI-USE POLE
STRUCTURE HEIGHT: 45'-0" (TOP OF ANTENNA)
ANTENNA RAD CENTER: 43'-4" AGL
APPLICANT: VERIZON WIRELESS
APPLICANT CONTACT: BRANDON KISER
3131 SOUTH VAUGHN WAY #550
AURORA, CO 80014
PH: 801-260-8700
ENGINEERING: AERO SOLUTIONS, LLC
ENGINEERING CONTACT: MATT FLECK
5555 CENTRAL AVENUE #100
BOULDER, CO 80301
PH: 720 279-8973
Z-4
REVISION SCHEDULE
REV
A
DATE
10-06-17
BY
GAC 90% ZONING DRAWINGS
DESCRIPTION
DRAWING TITLE:
DRAWING SHEET:
SITE INFORMATION:
OF 8
SITE NAME:
FTC BIG CITY SC7
SITE ADDRESS:
505 S. MASON ST.
FORT COLLINS, CO 80521
JURISDICTION:
CITY OF FORT COLLINS
3131 SOUTH VAUGHN WAY #500
AURORA, COLORADO 80014
(303) 873-2652
AERO PROJECT #: 097-16-0119
5555 CENTRAL AVENUE #100
BOULDER, COLORADO 80301
PH: (720) 304-6882
FAX: (720) 304-6883
SHEET NUMBER:
B 11-17-17 LCW REVISED ZONING DRAWINGS
C 01-24-18 LCW REVISED ZONING DRAWINGS
D 05-02-18 JID REVISED ZONING DRAWINGS
VICINITY MAP
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: RAM NANDIRAJU
EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM
VERIZON WIRELESS
3131 S. VAUGHN WAY #550
AURORA, CO 80014
CONTACT: JASON SHELLEDY
PHONE: 303-873-2652
PH-1 PHOTOSIMULATION VIEW
EXISTING ELEVATION
PROPOSED ELEVATION
LEGAL DESCRIPTION
LOT 1, MAX FLATS, COUNTY OF LARIMER, STATE OF COLORADO.
PM-1 PHOTOMETRIC PLAN
LD-1 LINE DRAWINGS