Loading...
HomeMy WebLinkAboutFTC BIG CITY, WIRELESS TELECOMMUNICATIONS EQUIPMENT - BASIC DEVELOPMENT REVIEW - BDR180022 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSFTC BIG CITY SC7 505 S. MASON ST. FORT COLLINS, CO 80521 SMALL CELL NSB ZONING DRAWINGS PROJECT AREA SITE DIRECTIONS FROM 3131 SOUTH VAUGHN WAY: GET ON I-225 N FROM SOUTH URSULA ST, S.VAUGHN WAY AND E. ILIFF AVE. FROM I-225 N TAKE E-470 N TO I-25 N. TAKE I-25 N TO CO-14W/ E MULBERRY ST IN LARIMER COUNTY. TAKE EXIT 269B FROM I-25 N. FOLLOW E. MULBERRY ST TO MASON ST IN FORT COLLINS. FORT COLLINS, COLORADO CLIENT PROPERTY OWNER VERIZON WIRELESS REAL ESTATE 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: BRANDON KISER PHONE: 801-260-8700 RHI 1 MAX FLATS LLC CONTACT: TAMMY PETERSON PHONE: 970-484-3454 5200 W 20TH ST GREELEY, CO 80634 AERO SOLUTIONS, LLC 5555 CENTRAL AVE #100 BOULDER, CO 80301 CONTACT: MATT FLECK PHONE: 720-279-8973 ENGINEER CONSTRUCTION MANAGER SITE ACQUISITION CENTERLINE SOLUTIONS 16035 TABLE MOUNTAIN PARKWAY GOLDEN, CO 80403 CONTACT: JEN DANIELS PHONE: 303-550-4820 RF ENGINEER PROJECT DATA CODE ANALYSIS IBC 2015 (W/LOCAL AMENDMENTS NEC 2017 NFPA-1 (2006) U - UTILITY IIB BUILDING CODE: ELECTRICAL CODE: FIRE SAFETY CODE: USE GROUP: CONSTRUCTION TYPE: SHEET INDEX T-1 TITLE SHEET Z-1 SITE PLAN Z-2 ENLARGED SITE PLAN Z-3 PROJECT DESCRIPTION 1. INSTALL NEW MULTI-USE POLE. 2. INSTALL (2) RRH'S AND ASSOCIATED EQUIPMENT WITHIN NEW MULTI-USE POLE. 3. INSTALL PROPOSED SMALL CELL ANTENNA ON NEW MULTI-USE POLE. REVISION SCHEDULE REV A DATE 10-06-17 BY GAC 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 8 SITE NAME: FTC BIG CITY SC7 SITE ADDRESS: 505 S. MASON ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0119 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: B 11-17-17 LCW REVISED ZONING DRAWINGS C 01-24-18 LCW REVISED ZONING DRAWINGS D 05-02-18 JID REVISED ZONING DRAWINGS PHOTOSIMULATION VIEWS PH-1 2 2 PH-1 PHOTOSIMULATION VIEW (AFTER, LOOKING WEST) N.T.S. 1 PH-1 PHOTOSIMULATION VIEW (BEFORE, LOOKING WEST) N.T.S. 1'-6" 45'-0" 10'-0" 10'-0" 45'-0" REVISION SCHEDULE REV A DATE 10-06-17 BY GAC 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 8 SITE NAME: FTC BIG CITY SC7 SITE ADDRESS: 505 S. MASON ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0119 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: B 11-17-17 LCW REVISED ZONING DRAWINGS C 01-24-18 LCW REVISED ZONING DRAWINGS D 05-02-18 JID REVISED ZONING DRAWINGS LINE DRAWING LD-1 3 1 LD-1 MULTIUSE POLE LINE DRAWING N.T.S. ALL ASSOCIATED SERVICE EQUIPMENT WITHIN POLE BASE PROPOSED QUASI OMNI ANTENNA MOUNTED TO POLE PROPOSED LED LIGHT (1) PROPOSED MULTI-USE POLE WITH CANISTER ANTENNA MOUNTED ON TOP S S SS SS O O O O O O O O O O O O O O ET AC E E E E E E E E E EXISTING 20'-0" UTILITY EASEMENT EXISTING UTILITY EASEMENT (WIDTH VARIES) REVISION SCHEDULE REV A DATE 10-06-17 BY GAC 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 8 SITE NAME: FTC BIG CITY SC7 SITE ADDRESS: 505 S. MASON ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0119 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: B 11-17-17 LCW REVISED ZONING DRAWINGS C 01-24-18 LCW REVISED ZONING DRAWINGS D 05-02-18 JID REVISED ZONING DRAWINGS 1 Z-4 Z-2 1 N GENERAL NOTES: 1. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 09/21/17. 2. THE PROPOSED FACILITY WILL CAUSE "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 3. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 4. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. (THERE IS NO HANDICAP ACCESS REQUIRED). 5. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. SS SS SS SS SS SS SS SS O O O O O O O O E E E E E 8'-7" 14'-7" REVISION SCHEDULE REV A DATE 10-06-17 BY GAC 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 8 SITE NAME: FTC BIG CITY SC7 SITE ADDRESS: 505 S. MASON ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0119 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: B 11-17-17 LCW REVISED ZONING DRAWINGS C 01-24-18 LCW REVISED ZONING DRAWINGS D 05-02-18 JID REVISED ZONING DRAWINGS 1 Z-4 N ENLARGED SITE PLAN Z-2 5 1 Z-2 ENLARGED SITE PLAN SCALE: 1"=10'-0" UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 EXISTING BUILDING EXISTING CEDAR FENCE 5 0 2.5 5 10 20 1 inch = 10 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) 8'-0" REVISION SCHEDULE REV A DATE 10-06-17 BY GAC 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 8 SITE NAME: FTC BIG CITY SC7 SITE ADDRESS: 505 S. MASON ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0119 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: B 11-17-17 LCW REVISED ZONING DRAWINGS C 01-24-18 LCW REVISED ZONING DRAWINGS D 05-02-18 JID REVISED ZONING DRAWINGS N EXISTING ELEVATION Z-3 6 1 Z-3 EXISTING ELEVATION SCALE: 1/8"=1'-0" UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 4 0 2 4 8 16 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) DRIVEWAY EXISTING 55'-0" TALL BUILDING EXISTING SIGN (TYP) EXISTING LANDSCAPING TOP OF FENCE 8'-0" AGL EXISTING CEDAR 45'-0" 43'-4" 10'-0" 1'-6" REVISION SCHEDULE REV A DATE 10-06-17 BY GAC 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 8 SITE NAME: FTC BIG CITY SC7 SITE ADDRESS: 505 S. MASON ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0119 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: B 11-17-17 LCW REVISED ZONING DRAWINGS C 01-24-18 LCW REVISED ZONING DRAWINGS D 05-02-18 JID REVISED ZONING DRAWINGS PROPOSED ELEVATION Z-4 7 1 Z-4 PROPOSED ELEVATION SCALE: 1/8"=1'-0" 4 0 2 4 8 16 1/8 inch = 1 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PROPOSED TOP OF ANTENNA 45'-0" AGL PROPOSED VERIZON RAD CENTER 43'-4" AGL TOP OF PROPOSED LED LIGHT 10'-0" AGL GRADE 4997' (NAVD 88) EXISTING 55'-0" TALL BUILDING EXISTING SIGN (TYP) S S SS SS O O O O O O O O O O O O O O ET AC 20'-0" S SS SS O O O O O O O O O O O O O O ET AC 20'-0" REVISION SCHEDULE REV A DATE 10-06-17 BY GAC 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 8 SITE NAME: FTC BIG CITY SC7 SITE ADDRESS: 505 S. MASON ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0119 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: B 11-17-17 LCW REVISED ZONING DRAWINGS C 01-24-18 LCW REVISED ZONING DRAWINGS D 05-02-18 JID REVISED ZONING DRAWINGS N 20 0 10 20 40 80 1 inch = 40 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) PHOTOMETRIC PLAN PM-1 8 1 PM-1 PHOTOMETRIC PLAN EXISTING SCALE: 1"=40'-0" EXISTING BUILDING MULBERRY ST MASON ST EXISTING CURB (TYP) EXISTING SIDEWALK (TYP) EXISTING CMU WALL (TYP) EXISTING BUILDING MULBERRY ST MASON ST EXISTING CURB (TYP) EXISTING SIDEWALK (TYP) (1) PROPOSED MULTI-USE POLE WITH CANISTER ANTENNA MOUNTED ON TOP EXISTING CMU WALL (TYP) EXISTING WALL MOUNTED LIGHT FIXTURE (TYP) EXISTING LED LIGHT POLE EXISTING POLE MOUNTED LIGHT EXISTING FENCE (TYP) 20'-0" PROPERTY LINE OFFSET EXISTING WALL MOUNTED LIGHT FIXTURE (TYP) EXISTING LED LIGHT POLE EXISTING POLE MOUNTED LIGHT EXISTING FENCE (TYP) 20'-0" PROPERTY LINE OFFSET 20 0 10 20 40 80 1 inch = 40 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) 2 PM-1 PHOTOMETRIC PLAN PROPOSED SCALE: 1"=40'-0" EXISTING LANDSCAPING EXISTING CEDAR FENCE PROPOSED MULTI-USE POLE (FINAL DESIGN TBD) (PAINTED GRAY TO MATCH EXISTING LIGHT POLES) PROPOSED VERIZON ANTENNA MOUNTED ON MULTI-USE POLE NOTE: 1. PROPOSED LIGHTING TO CONFORM TO SECTION 3.2.4 OF THE FORT COLLINS LAND USE CODE 2. PER CITY FLOOD RISK MAP DATED 1/2/2018 PROVIDED BY THE CITY OF FORT COLLINS, THE EXISTING FLOODPLAIN AT THE TOWER LOCATION IS 4,996.663' (CONVERTED TO NAVD 88) FENCE (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) GENERAL NOTES: 1. THE CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE CODES ORDINANCES, LAWS AND REGULATIONS OF ALL MUNICIPALITIES, UTILITY COMPANIES OR OTHER PUBLIC AUTHORITIES. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTIONS THAT MAY BE REQUIRED BY ANY FEDERAL, STATE, COUNTY OR MUNICIPAL AUTHORITIES. 3. THE CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER, IN WRITING, OF ANY CONFLICTS, ERRORS OR OMISSIONS PRIOR TO THE SUBMISSION OF BIDS OR PERFORMANCE OF WORK. MINOR OMISSIONS OR ERRORS IN THE BID DOCUMENTS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR THE OVERALL INTENT OF THESE DRAWINGS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING SITE IMPROVEMENTS PRIOR TO COMMENCING CONSTRUCTION. THE CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED AS A RESULT OF CONSTRUCTION OF THIS FACILITY. 5. THE SCOPE OF WORK FOR THIS PROJECT SHALL INCLUDE PROVIDING ALL MATERIALS, EQUIPMENT AND LABOR REQUIRED TO COMPLETE THIS PROJECT. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. 6. THE CONTRACTOR SHALL VISIT THE PROJECT SITE PRIOR TO SUBMITTING A BID TO VERIFY THAT THE PROJECT CAN BE CONSTRUCTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 7. THIS PLAN WAS PREPARED USING AN APPROVED SURVEY PLAN ENTITLED "BOUNDARY DETAIL" BY RLF CONSULTING, DATED 09/21/17. 8. THE PROPOSED FACILITY WILL CAUSE ONLY A "DE MINIMIS" INCREASE IN STORMWATER RUNOFF. THEREFORE, NO DRAINAGE STRUCTURES ARE PROPOSED. 9. NO SMOKE, DUST, OR ODOR WILL RESULT FROM THIS FACILITY. 10. THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION (THERE IS NO HANDICAP ACCESS REQUIRED). 11. THE FACILITY IS UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SANITARY SERVICE. 12. POWER TO THE FACILITY WILL BE MONITORED BY A SEPARATE METER. 13. CONTRACTOR SHALL VERIFY ANTENNA ELEVATION AND AZIMUTH WITH RF ENGINEERING PRIOR TO INSTALLATION. 14. MOUNTS AND ANTENNAS ARE DESIGNED TO MEET TIA-222-G AS PER IBC 2015 REQUIREMENTS. 15. ALL STRUCTURAL ELEMENTS SHALL BE HOT DIPPED GALVANIZED STEEL. 16. CONTRACTOR SHALL MAKE A UTILITY "ONE CALL" TO LOCATE ALL UTILITIES PRIOR TO EXCAVATING. 17. IF ANY PIPING EXISTS BENEATH THE SITE AREA, CONTRACTOR MUST LOCATE IT AND CONTACT OWNERS REPRESENTATIVE. 18. LENGTHS ARE ESTIMATES; CONTRACTOR AND/OR CONSTRUCTION MANAGER SHALL FIELD VERIFY ALL LENGTHS PRIOR TO ORDERING PROPOSED 10'-0" WIDE ACCESS EASEMENT PROPOSED 10'x10' LEASE AREA PROPOSED 5'-0" WIDE UTILITY EASEMENT PROPOSED UNDERGROUND FIBER RUN TO EQUIPMENT (UNDERGROUND MEET POINT TO BE DETERMINED) PROPOSED 4'x4' FUTURE LEASE AREA (1) PROPOSED MULTI-USE POLE WITH CANISTER ANTENNA MOUNTED ON TOP EXISTING CMU WALL PROPOSED 5'-0" WIDE UTILITY EASEMENT PROPOSED POWER TO BE PULLED FROM EXISTING TRANSFORMER MASON ST ANTENNA DESIGNATION CABLE TABLE ±55' LENGTH 2 NO. TYPE CONDUIT WITH 3-CELL PLENUM FIBER IN CONDUIT N/A FIBER RUN ±10' 1 2" 1/2" COAX SIZE MAXCELL INNERDUCT 6. ELEVATIONS REFER TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 1988). 7. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE STREET SIGNS OF ANY TYPE. 8. THE PROPOSED DEVELOPMENT DOES NOT INCLUDE OUTDOOR STORAGE OR ANY SOLID WASTE RECEPTACLES. VERIZON COLOR STANDARDS GRAY-EXISTING EASEMENT ORANGE-FIBER TAN-ANTENNAS RED-PENETRATIONS UMBER-NEW WORK UTILITY EASEMENT BLUE #1-HYBRID CABLES/COAX BLUE GRAY#1- ACCESS/UTILITY PURPLE #1- LEASE AREA BLUE #2-RRHS GRAY-WALL HATCH GREEN-DC POWER GREY-EXISTING LEGEND W SS F GAS GAS OE UT X X S WV T WM ICV E WATER LINE SANITARY SEWER GAS LINE FIBER LINE OH ELECTRIC UG TELCO FENCE CLF RIGHT OF WAY WATER METER WATER VALVE IRRIGATION VALVE SAN SEWER MH TELCO MAN HOLE LIGHT POLE ELEC PULL BOX SD SD E UE OT EV D O O U/G OHW STORM DRAIN UG ELECTRIC ELECTRIC OH TELCO PROPERTY LINE FENCE IRON UG UTILITIES OH UTILITIES SIGNAGE CATCH BASIN STORM MANHOLE POWER POLE TRAFFIC SIGNAL ELECTRIC VAULT ELECTRIC CABINET ELECTRIC EQUIP EQ ELECTRICAL XFMR ET 20 0 10 20 40 80 1 inch = 40 ft. ( IN FEET ) GRAPHIC SCALE (SCALE BASED ON 11"x17" SHEETS ONLY) (DO NOT USE SCALE ON OTHER SIZED DRAWINGS) SITE PLAN Z-1 4 1 Z-1 SITE PLAN SCALE: 1"=40'-0" UTILITY NOTIFICATION CENTER Know what's below. Call before you dig. TOLL FREE 1800-227-2600 EXISTING BUILDING MULBERRY ST MASON ST EXISTING 20' ALLEY EXISTING CURB (TYP) EXISTING SIDEWALK (TYP) PROPOSED 10'-0" WIDE ACCESS EASEMENT PROPOSED 10'x10' LEASE AREA PROPOSED 5'-0" WIDE UTILITY EASEMENT PROPOSED UNDERGROUND FIBER RUN TO EQUIPMENT (UNDERGROUND MEET POINT TO BE DETERMINED) PROPOSED 5'-0" WIDE UTILITY EASEMENT PROPOSED POWER TO BE PULLED FROM EXISTING TRANSFORMER PROPOSED 4'x4' FUTURE LEASE AREA (1) PROPOSED MULTI-USE POLE WITH CANISTER ANTENNA MOUNTED ON TOP EXISTING CMU WALL (TYP) NOTE: NO WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNER OR LESSEE OR EMPLOYEE THEREOF SHALL ACT TO EXCLUDE OR ATTEMPT TO EXCLUDE ANY OTHER WIRELESS TELECOMMUNICATION PROVIDER FROM USING THE SAME BUILDING, STRUCTURE OR LOCATION. WIRELESS TELECOMMUNICATION FACILITY OR EQUIPMENT OWNERS OR LESSEES OR EMPLOYEES THEREOF, AND APPLICANTS FOR THE APPROVAL OF PLANS FOR THE INSTALLATION OF SUCH FACILITIES OR EQUIPMENT, SHALL COOPERATE IN GOOD FAITH TO ACHIEVE CO-LOCATION OF WIRELESS TELECOMMUNICATION FACILITIES AND EQUIPMENT 4. INSTALL NEW UNDERGROUND FIBER AND POWER TO PROPOSED EQUIPMENT. 5. INSTALL COAX FROM EQUIPMENT TO ANTENNA. VERIZON (RF): DATE: DATE: DATE: DATE: VERIZON (CONST.): VERIZON (RE): LANDLORD: APPROVALS TITLE SHEET T-1 1 JURISDICTION: CITY OF FORT COLLINS ZONING: DOWNTOWN DISTRICT APN: 9714123001 PARCEL SIZE: 0.68 AC ELEVATION: 4,997' (NAVD 88) STRUCTURE TYPE: NEW MULTI-USE POLE STRUCTURE HEIGHT: 45'-0" (TOP OF ANTENNA) ANTENNA RAD CENTER: 43'-4" AGL APPLICANT: VERIZON WIRELESS APPLICANT CONTACT: BRANDON KISER 3131 SOUTH VAUGHN WAY #550 AURORA, CO 80014 PH: 801-260-8700 ENGINEERING: AERO SOLUTIONS, LLC ENGINEERING CONTACT: MATT FLECK 5555 CENTRAL AVENUE #100 BOULDER, CO 80301 PH: 720 279-8973 Z-4 REVISION SCHEDULE REV A DATE 10-06-17 BY GAC 90% ZONING DRAWINGS DESCRIPTION DRAWING TITLE: DRAWING SHEET: SITE INFORMATION: OF 8 SITE NAME: FTC BIG CITY SC7 SITE ADDRESS: 505 S. MASON ST. FORT COLLINS, CO 80521 JURISDICTION: CITY OF FORT COLLINS 3131 SOUTH VAUGHN WAY #500 AURORA, COLORADO 80014 (303) 873-2652 AERO PROJECT #: 097-16-0119 5555 CENTRAL AVENUE #100 BOULDER, COLORADO 80301 PH: (720) 304-6882 FAX: (720) 304-6883 SHEET NUMBER: B 11-17-17 LCW REVISED ZONING DRAWINGS C 01-24-18 LCW REVISED ZONING DRAWINGS D 05-02-18 JID REVISED ZONING DRAWINGS VICINITY MAP VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: RAM NANDIRAJU EMAIL: RAM.NANDIRAJU@VERIZONWIRELESS.COM VERIZON WIRELESS 3131 S. VAUGHN WAY #550 AURORA, CO 80014 CONTACT: JASON SHELLEDY PHONE: 303-873-2652 PH-1 PHOTOSIMULATION VIEW EXISTING ELEVATION PROPOSED ELEVATION LEGAL DESCRIPTION LOT 1, MAX FLATS, COUNTY OF LARIMER, STATE OF COLORADO. PM-1 PHOTOMETRIC PLAN LD-1 LINE DRAWINGS