HomeMy WebLinkAbout112 W. MAGNOLIA STREET PARKING LOT - FDP - FDP180017 - SUBMITTAL DOCUMENTS - ROUND 1 - GEOTECHNICAL (SOILS) REPORTSoilogic, Inc.
3050 67th Avenue, Suite 200 Greeley, CO 80634 (970) 535-6144
P.O. Box 1121 Hayden, CO 81639 (970) 276-2087
April 24, 2017
Quality Engineering, LLC
2637 Midpoint Drive, Suite E
Fort Collins, Colorado 80234
Attn: Mr. Cody Geisendorfer, P.E.
Re: Addendum #1 to Geotechnical Subsurface Exploration and
Pavement Section Design Report
Wells Fargo Parking Lot
112 West Magnolia Street, Fort Collins, Colorado
Soilogic Project # 16-1181
Mr. Geisendorfer:
Our geotechnical subsurface exploration and pavement section design for the referenced
project was submitted to your attention in a report dated August 11, 2016. In that report,
a minimum 5-inch thick unreinforced Portland cement concrete pavement section design
was recommended based in-part on the quantity and type of traffic anticipated to utilize
the parking lot as well as subgrade support characteristics. At this time, we understand a
6-inch thick Portland cement concrete pavement supported on two (2) inches of 1-inch
minus granular fill overlying eight (8) inches of 1-inch clean rock will be constructed as
part of a permeable pavement system. The proposed section as outlined above is
structurally greater than the minimum recommended in our pavement design report and
in our opinion, would be considered an adequate design alternative from a geotechnical
standpoint.
We appreciate the opportunity to be of service to you on this project. If we can be of
further service to you in any way or if you have any questions concerning the enclosed
information, please do not hesitate to contact us.
Very Truly Yours,
Soilogic, Inc. Reviewed by:
Wolf von Carlowitz, P.E. Darrel DiCarlo, P.E.
Principal Engineer Senior Project Engineer
36746 44271