Loading...
HomeMy WebLinkAboutFTC FOXSTONE, WTE (VERIZON) - PDP - PDP180007 - SUBMITTAL DOCUMENTS - ROUND 1 - PLANSSITE NAME: SITE ADDRESS: FTC FOXSTONE 1961 CARIBOU DR. FT.COLLINS, CO 80525 LARIMER COUNTY DRAWING INDEX T1 TITLE SHEET LS1 LAND SURVEY LS2 SITE LOCATION Z3.1 NORTH & EAST ELEVATIONS Z1 OVERALL SITE PLAN Z2 ENLARGED SITE PLAN, EQUIPMENT PLAN & ANTENNA DETAIL GENERAL CONTRACTOR NOTE PROJECT TEAM APPROVAL BLOCK TITLE SIGNATURE DATE OWNER ENGINEER PROJECT MANAGER ACKNOWLEDGEMENT OR "SIGN-OFF" BY PARTIES TO THE CONSTRUCTION DRAWINGS DOES NOT CONSTITUTE ALTERATION OF THE LEASE TERMS. PROPERTY OWNER: SECURCARE PROPERTIES I LLC. CONTACT: CALEB CROSSLAND PHONE: 970.222.1341 VICINITY MAP DRIVING DIRECTIONS TO SITE PROJECT DESCRIPTION NEW UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF (3) SECTORS OF CONCEALED ANTENNAS, AND CONCEALED EQUIPMENT ON A NEW SELF SUPPORT TOWER. PROJECT DATA JURISDICTION: PARCEL NUMBER: ZONING DESIGNATION: OCCUPANCY GROUP: CONSTRUCTION TYPE: FULLY SPRINKLERED: NO. OF STORIES: GOVERNING CODES IF APPLICABLE: 2015 IBC, 2015 IECC, 2015 IFC, 2015 IMC, 2015 IPC, 2015 IRBC, 2014 NEC. A.D.A. COMPLIANCE: NOT REQUIRED PER IBC 1103.2.9 - - - - - - - CITY OF FT.COLLINS 8731422001 P.U.D. U V-B NO 1 LEGAL DESCRIPTION: THE LAND REFERRED TO IN SCHEDULE A IS SITUATED IN THEW COUNTY VZW 16035 TABLE MOUNTAIN PARKWAY GOLDEN, CO 80403 303-993-3293 WWW.CENTERLINESOLUTIONS.COM 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION: PLANS PREPARED BY: LICENSURE NO: SITE NAME: REV: DATE: DESCRIPTION: BY: DRAWN BY: CHK BY: APV BY: SHEET TITLE: SHEET NUMBER: FTC FOXSTONE 1961 CARIBOU DR. FORT COLLINS, CO 80525 LARIMER COUNTY GW BB KS 1 03/23/18 90% ZONING GW 2 04/06/18 90% ZONING REV A GW 3 05/01/18 90% ZONING REV B GW PRELIMINARY - NOT FOR CONSTRUCTION Z1 OVERALL SITE PLAN 1 OVERALL SITE PLAN SCALE: 1" = 20'-0" (11X17) 0' 10' 20' 40' SCALE: 1" = 10'-0" (24X36) EX. PAVED DRIVEWAY EX. STORAGE UNIT ROOFTOP EX. PAVED STORAGE UNITS ROOFTOP NEW VZW UTILITY EASEMENT NEW VZW ACCESS EASEMENT NEW VZW LEASE AREA, (250 S.F.) LEASE LEGEND EX. PARKING LOT OF ADJACENT PROPERTY EX. PAVED DRIVEWAY EX. PAVED DRIVEWAY EX. TREE (TYP.) EX. CONCRETE CURB (TYP.) 1 ENLARGED SITE PLAN 3 EQUIPMENT PLAN 2 ANTENNA DETAIL 16035 TABLE MOUNTAIN PARKWAY GOLDEN, CO 80403 303-993-3293 WWW.CENTERLINESOLUTIONS.COM 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION: PLANS PREPARED BY: LICENSURE NO: SITE NAME: REV: DATE: DESCRIPTION: BY: DRAWN BY: CHK BY: APV BY: SHEET TITLE: SHEET NUMBER: FTC FOXSTONE 1961 CARIBOU DR. FORT COLLINS, CO 80525 LARIMER COUNTY GW BB KS 1 03/23/18 90% ZONING GW 2 04/06/18 90% ZONING REV A GW 3 05/01/18 90% ZONING REV B GW PRELIMINARY - NOT FOR CONSTRUCTION Z2 ENLARGED SITE PLAN EQUIPMENT PLAN & ANTENNA DETAIL SCALE: 1" = 10'-0" (11X17) 0' 5' 10' 20' SCALE: 1" = 5'-0" (24X36) SCALE: 1/4"= 1'-0" (11X17) SCALE: 1/2" = 1'-0" (24X36) 0' 2' 4' 8' X SECTOR AZIMUTH 110° Y SECTOR AZIMUTH 200° GAMMA SECTOR AZIMUTH 350° (12) NEW VZW ANTENNAS MOUNTED TO NEW PIPE MOUNTS BEHIND RF TRANSPARENT WALL (4) PER SECTOR) (12) NEW VZW RRU'S MOUNTED TO NEW PIPES ON BACK OF ANTENNAS (4) PER SECTOR) NEW VZW 40'-0" MONOPOLE (BY OTHERS) SCALE: 1/4"= 1'-0" (11X17) SCALE: 1/2" = 1'-0" (24X36) 0' 2' 4' 8' EX. STORAGE UNIT ROOFTOP EX. CONCRETE CURB (TYP.) EX. ROLLING GATE EX. SCISSOR GATE L S LL S 54 930 270 240v 3w 1 12121212 16035 TABLE MOUNTAIN PARKWAY GOLDEN, CO 80403 303-993-3293 WWW.CENTERLINESOLUTIONS.COM 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION: PLANS PREPARED BY: LICENSURE NO: SITE NAME: REV: DATE: DESCRIPTION: BY: DRAWN BY: CHK BY: APV BY: SHEET TITLE: SHEET NUMBER: FTC FOXSTONE 1961 CARIBOU DR. FORT COLLINS, CO 80525 LARIMER COUNTY GW BB KS 1 03/23/18 90% ZONING GW 2 04/06/18 90% ZONING REV A GW 3 05/01/18 90% ZONING REV B GW PRELIMINARY - NOT FOR CONSTRUCTION Z3.1 NORTH & EAST ELEVATIONS 1 NORTH ELEVATION 2 EAST ELEVATION SCALE: 1/16" = 1'-0" (11X17) SCALE: 1/8" = 1'-0" (24X36) 0' 8' 16' 32' SCALE: 1/16" = 1'-0" (11X17) SCALE: 1/8" = 1'-0" (24X36) 0' 8' 16' 32' EX. STORAGE UNIT EX. BUSINESS OFFICE EX. SIGN EX. PAD MOUNTED TRANSFORMER EX. BOLLARD AND KEYPAD AT ROLLING GATE NEW VZW LIGHTNING ROD EX. STORAGE UNIT & OFFICE EX. TREES (TYP.) EX. BUILDING EX. SIGN (12) NEW VZW ANTENNAS L S LL S 54 930 270 240v 3w 1 12121212 Z3.2 WEST ELEVATION 16035 TABLE MOUNTAIN PARKWAY GOLDEN, CO 80403 303-993-3293 WWW.CENTERLINESOLUTIONS.COM 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION: PLANS PREPARED BY: LICENSURE NO: SITE NAME: REV: DATE: DESCRIPTION: BY: DRAWN BY: CHK BY: APV BY: SHEET TITLE: SHEET NUMBER: FTC FOXSTONE 1961 CARIBOU DR. FORT COLLINS, CO 80525 LARIMER COUNTY GW BB KS 1 03/23/18 90% ZONING GW 2 04/06/18 90% ZONING REV A GW 3 05/01/18 90% ZONING REV B GW PRELIMINARY - NOT FOR CONSTRUCTION 1 WEST ELEVATION 2 NOT USED SCALE: N.T.S. SCALE: 1/16" = 1'-0" (11X17) SCALE: 1/8" = 1'-0" (24X36) 0' 8' 16' 32' SCALE: NTS SCALE: NTS T.O. NEW TOWER ELEV. 40'-0" C.L. NEW VZW ANTENNAS ELEV. 35'-0" T.O. NEW LIGHTNING ROD ELEV. 45'-0" EX. PAD MOUNTED TRANSFORMER EX. BOLLARD (TYP.) NEW VZW LIGHTNING ROD EX. STORAGE UNIT & OFFICE EX. TREES (TYP.) EX. BUILDING (2) NEW VZW EQUIPMENT CABINETS MOUNTED ON NEW PLINTH ON CONC. SLAB WITHIN NEW VZW FENCED LEASE AREA ELEV. 8'-9"± T.O. EX. STORAGE UNIT ELEV. 0'-0" EX. GRADE NEW VZW METER, DISCONNECT AND ILC CABINET MOUNTED TO NEW UNISTRUT H-FRAME EX. TREES BEYOND (TYP.) EX. ROLLING GATE AND OPERATOR EX. TREE TO BE REMOVED (12) NEW VZW ANTENNAS MOUNTED TO NEW SECTOR FRAMES TYP. (4) PER SECTOR) (12) NEW VZW RRU'S MOUNTED TO NEW PIPES ON BACK OF ANTENNAS (4) PER SECTOR) (NOT VISIBLE) (2) NEW VZW OVP'S MOUNTED TO NEW SECTOR FRAMES MOUNTED TO NEW SECTOR FRAMES TYP. (4) PER SECTOR) (12) NEW VZW RRU'S MOUNTED TO NEW PIPES ON BACK OF ANTENNAS (4) PER SECTOR) (NOT VISIBLE) (2) NEW VZW OVP'S MOUNTED TO NEW SECTOR FRAMES T.O. NEW TOWER ELEV. 40'-0" C.L. NEW VZW ANTENNAS ELEV. 35'-0" T.O. NEW LIGHTNING ROD ELEV. 45'-0" ELEV. 8'-9"± T.O. EX. STORAGE UNIT ELEV. 0'-0" EX. GRADE EX. SCISSOR GATE EX. ROLLING GATE (12) NEW VZW RRU'S MOUNTED TO NEW PIPES ON BACK OF ANTENNAS (4) PER SECTOR) (NOT VISIBLE) T.O. NEW TOWER ELEV. 40'-0" C.L. NEW VZW ANTENNAS ELEV. 35'-0" T.O. NEW LIGHTNING ROD ELEV. 45'-0" ELEV. 8'-9"± T.O. EX. STORAGE UNIT ELEV. 0'-0" EX. GRADE NEW VZW 40' MONOPOLE W/ NEW VZW ANTENNAS AND RELATED EQUIPMENT MOUNTED TO NEW SECTOR FRAMES EX. TREE TO BE REMOVED EX. TREE TO BE REMOVED EX. BUILDING NEW VZW LIGHTNING ROD NEW VZW 40' MONOPOLE W/ NEW VZW ANTENNAS AND RELATED EQUIPMENT MOUNTED TO NEW SECTOR FRAMES (2) NEW VZW OVP'S MOUNTED TO NEW SECTOR FRAMES (12) NEW VZW ANTENNAS MOUNTED TO NEW SECTOR FRAMES TYP. (4) PER SECTOR) EX. GAS METER EX. TRASH ENCLOSURE EX. PAVED DRIVEWAY EX. U/G ELECTRICAL (TYP.) EX. U/G TELCO LINE (TYP.) EX. U/G GAS LINE (TYP.) EX. DRAINAGE SWALE EX. CONCRETE CURB (TYP.) EX. TREE EX. KEY PAD NEW VZW U/G POWER RUN WITHIN NEW 5'-0" UTILITY EASEMENT (2) NEW VZW EQUIPMENT CABINETS MOUNTED TO NEW 2-BAY PLINTH ON NEW CONC. SLAB NEW VZW METER, DISCONNECT AND ILC CABINET MOUNTED TO NEW UNISTRUT H-FRAME EX. U/G TELCO LINE (TYP.) EX. U/G ELECTRICAL RUN WILL NEED TO BE RE-ROUTED EX. CONCRETE CURB (TYP.) EX. ROLLING GATE EX. SCISSOR GATE NEW VZW U/G FIBER RUN WITHIN NEW CONDUIT W/ (3) INNERDUCTS NEW VZW U/G FIBER RUN IN 2" CONDUIT W/ (3) INNERDUCTS FROM NEW FIBER HAND HOLE NEW VZW U/G POWER RUN WITHIN NEW CONDUIT FROM EX. PAD MOUNTED TRANSFORMER (BY OTHERS) (2) NEW VZW EQUIPMENT CABINETS MOUNTED TO NEW 2-BAY PLINTH ON CONC. SLAB (SEE DET. 3/Z2) (2) NEW VZW OVP MOUNTED TO NEW PIPE EX. GATE OPERATOR KEYPAD EX. CONCRETE FILLED BOLLARD NEW VZW FENCING TO MATCH EXISTING, W/ 5' SECURED GATE EX. GATE OPERATOR KEYPAD EX. U/G ELECTRICAL RUN WILL NEED TO BE RE-ROUTED NEW VZW FENCING TO MATCH EXISTING, W/ 5' SECURED GATE 5'-0" UTILITY EASMENT 5'-0" UTILITY EASMENT NEW VZW LEASE AREA (182 S.F.) NEW VZW 40'-0" MONOPOLE W/ NEW VZW ANTENNAS & EQUIPMENT (SEE DET. 1/Z2) NEW VZW METER, DISCONNECT AND ILC CABINET MOUNTED TO NEW UNISTRUT H-FRAME (SEE DET. 3/Z2) NEW VZW CONCRETE PAD EX. TELCO JUNCTION BOX (TYP.) EX. U/G TELCO LINE (TYP.) EX. TELCO BOX (TYP.) CARIBOU DR. AUTOMATION WAY EX.ADJACENT BUILDING EX. PAD MOUNTED TRANSFORMER NEW VZW 15'-0" WIDE ACCESS EASEMENT (P) 5'-0" WIDE UTILITY EASEMENT EX. CONCRETE WALL W/ SIGNAGE EX. U/G GAS LINE EX PROPERTY LINE (TYP.) EX. ROLLING GATE EX. SCISSOR GATE EX. GAS METER EX. TREE TO BE REMOVED NEW VZW 40'-0" MONOPOLE W/ NEW VZW ANTENNAS & EQUIPMENT (SEE DET. 1/Z2) NEW VZW METER, DISCONNECT AND ILC CABINET MOUNTED TO NEW UNISTRUT H-FRAME (SEE DET. 1/Z2) EX. KEY PAD (TYP.) EX. PARKING LOT EX. ELECTRICAL METER (TYP.) EX. BUILDING ROOFTOP EX. BUILDING ROOFTOP EX. BUILDING ROOFTOP EX. BUILDING ROOFTOP NEW VZW U/G FIBER HAND HOLE NEW VZW U/G FIBER RUN WITHIN NEW CONDUIT FROM NEW FIBER HAND HOLE (BY OTHERS) NEW VZW U/G POWER RUN WITHIN NEW CONDUIT FROM EX. PAD MOUNTED TRANSFORMER (BY OTHERS) 51'-4 1/2" SETBACK 64'-0 1/2" SETBACK NEW VZW LEASE AREA (182 S.F.) OF LARIMER, STATE OF COLORADO AND IS DESCRIBED AS FOLLOWS: PARCEL ONE: LOT 1, TIMBERLINE STORAGE P.U.D., COUNTY OF LARIMER, STATE OF COLORADO. PARCEL TWO: LOT 1, A PLAT OF TIMBERLINE STORGE P.U.D., SECOND FILING, A MINOR SUBDIVISION, COUNTY OF LARIMER, STATE OF COLORADO. POWER COMPANY: TELCO COMPANY: CONTACT: TBD WK: / CELL: CONTACT: TBD WK: / CELL: UTILITIES APPLICANT: VERIZON 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. DRAWING SCALES SHOWN ARE ACCURATE WHEN PLOTTED ON 11"X17" SHEET. FOR 24"X36" SHEETS USE APPROPRIATE SCALE FACTOR 2X THAT OF SCALE SHOWN OR CONTACT CENTERLINE SOLUTIONS FOR FURTHER INFORMATION. DIMENSIONS SHOWN TAKE PRECEDENCE. CALL 811 TWO BUSINESS DAYS BEFORE DIGGING. THE CONTRACTOR SHALL NOTIFY ONE CALL TO LOCATE ALL UNDERGROUND FACILITIES BEFORE DIGGING. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO STAY CLEAR OF ALL UNDERGROUND FACILITIES. THESE DRAWINGS MAY NOT SHOW ALL UNDERGROUND PIPING AND UTILITIES. THE CONTRACTOR SHALL EXERCISE EXTREME CARE DURING ALL EXCAVATION AND OTHER CONSTRUCTION ACTIVITIES. VERIZON WIRELESS IS RESPONSIBLE FOR ALL UTILITY LOCATES AND UTILITY RELOCATIONS REQUIRED FOR THIS INSTALLATION. VERIZON WIRELESS WILL SCHEDULE AND COORDINATE ALL WORK WITH THE OWNER TO ENSURE NO DISRUPTION TO OWNERS OPERATIONS. VERIZON WIRELESS SHALL BE ABBREVIATED "VZW" THROUGHOUT. FROM THE VERIZON OFFICE LOCATED AT 3131 S. VAUGHN WAY, AURORA, COLORADO: TAKE I-225 FOR 7.6 MILES TO EXIT 1A. TAKE RAMP LEFT FOR I-70 WEST TOWARD DENVER FOR 13.4 MILES. AT EXIT 269A TAKE RAMP RIGHT AND FOLLOW SIGNS FOR CO-121 NORTH. TRAVEL NORTH FOR 1.1 MILE. TURN LEFT ONTO OLDE WADSWORTH BLVD. (STREET BECOMES WEST 53RD AVE. ON RIGHT AND OLDE WADSWORTH AVE. ON LEFT). DRIVE NORTHWEST AND NORTH ON OLDE WADSWORTH AVE. FOR .5 MILE AND TURN LEFT ONTO GRANDVIEW AVE. ARRIVE AT SITE ON THE LEFT IN 249 FEET. 16035 TABLE MOUNTAIN PARKWAY GOLDEN, CO 80403 303-993-3293 WWW.CENTERLINESOLUTIONS.COM 3131 S. VAUGHN WAY, SUITE 550 AURORA, CO 80014 PROJECT INFORMATION: PLANS PREPARED BY: LICENSURE NO: SITE NAME: REV: DATE: DESCRIPTION: BY: DRAWN BY: CHK BY: APV BY: SHEET TITLE: SHEET NUMBER: T1 TITLE SHEET TBD ISSUED FOR: ZONING FTC FOXSTONE 1961 CARIBOU DR. FORT COLLINS, CO 80525 LARIMER COUNTY GW BB KS 1 03/23/18 90% ZONING GW 2 04/06/18 90% ZONING REV A GW 3 05/01/18 90% ZONING REV B GW PRELIMINARY - NOT FOR CONSTRUCTION CIVIL SURVEYOR: DALEY LAND SURVEYING, INC. 17011 LINCOLN AVENUE STE. 361 PARKER, CO 80134-3144 ROB DALEY, PLS PH: 303.953.9841 SITE ACQUISITION: CENTERLINE SOLUTIONS, LLC GREG DIBONA PH: 303.993.3293 EXT. 1452 RF ENGINEER: VERIZON WIRELESS KEVIN BROWN PH: 301.787.7316 CONSTRUCTION MANAGER: VERIZON MARK WILSON 303.905.9324 A&E FIRM: CENTERLINE SOLUTIONS, LLC BRAD BRYANT, PM PH: 303.993.3293 X1383 LAND SURVEY ENGINEER OF RECORD: CENTERLINE SOLUTIONS, LLC KHRISTOPHER SCOTT, PE PH: 303.993.3293 REFERENCE DOCUMENTS Z3.2 WEST ELEVATION UC1 UTILITY COORDINATION PLAN