Loading...
HomeMy WebLinkAboutSAINT JOHN XXIII CATHOLIC CHURCH AND LOMBARDY STUDENT HOUSING - PDP190001 - DOCUMENT MARKUPS - ROUND 2 - SITE PLANSheet Number: Project Number: Project: Client: 1603 Oakridge Drive Fort Collins, CO 80525 p. (970) 223-7577 www.BHADesign.com Landscape Architecture Urban Design Master Planning L:\PROJECTS\SAINT JOHN XXIII\DRAWINGS\ACAD\PDP\DWG\1847 - J23 SITE PLAN.DWG Plot Date:5/1/2019 10:07 AM Plotted By: Jason Messaros Date Created:9/17/2018 Produced by: Date: Revision: 1 OF 6 Date: COVER SHEET Saint John XXIII Catholic Church Lombardy Student Housing, PDP190001 1220 University Ave, Fort Collins, CO 80521 BLACKBIRD INVESTMENTS LLC 130 East 3rd St. Suite 400 Des Moines, IA 50309 PROJECT DEVELOPMENT PLAN (PDP) JM 5.1.2019 1847 LEGAL DESCRIPTION VICINITY MAP BEING A REPLAT OF LOTS 1, 2 AND 3, PLAT OF JOHN XXIII UNIVERSITY CENTER AND LOT 1, CAMPUS WEST TEXACO MINOR SUBDIVISION, LOCATED IN THE SOUTHEAST QUARTER OF SECTION 15, TOWNSHIP 7 NORTH, RANGE 69 WEST OF THE 6TH PRINCIPAL MERIDIAN, CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO. St. John XXIII Catholic Church 1220 University Ave, Fort Collins, CO 80521 N O R T H LAND USE DATA · EXISTING ZONING COMMUNITY COMMERCIAL DISTRICT, TOD · PROPOSED LAND USE MIXED USE: PLACE OF WORSHIP AND RENT BY THE UNIT MULTI-FAMILY RESIDENTIAL · MAX. BUILDING HEIGHT PERMITTED FIVE (5) STORIES · MAX. BUILDING HEIGHT PROPOSED FIVE (5) STORIES · GROSS SITE AREA 242,069 S.F. (5.56ACRES) · ESTIMATED FLOOR AREA 362,030 S.F. · FLOOR AREA RATIO 1.49 FAR · PUBLIC R.O.W 2,967 S.F. · AMENITY SPACE - PRIVATE COURTYARD 9,000 S.F. · NET SITE AREA 239,102 S.F. (5.49 ACRES) TOTAL SITE COVERAGE AREA PERCENT BUILDING COVERAGE 84,133 S.F. 34.7% DRIVES & PARKING 31,747 S.F. 13% LANDSCAPE AREA AND WALKS (OPEN SPACE) 114,222 S.F. 47.4% PUBLIC R.O.W. 2,967 S.F. 1.2% ACTIVE RECREATIONAL USE (AMENITY SPACE) 9,000 S.F. 3.7% TOTAL 242,069 S.F. 100% PARKING ANALYSIS AND REQUIREMENTS: AS PER FORT COLLINS LAND USE CODE, SEC. 3.2.3-K.2.c BUILDING A (AFFORDABLE HOUSING UNITS: 34): (54) 0NE-BEDROOM/STUDIO UNITS (54) X .75 = 40.5 REQUIRED SPACES (25) TWO-BEDROOM UNITS (25) X 1 = 25 REQUIRED SPACES (19) THREE-BEDROOM UNITS (19) X 1.25 = 23.75 REQUIRED SPACES TOTAL (BUILDING A) 90 PARKING SPACES DN B M C C T T T T M T T W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ST ST W W W W W W W W W W W W W W W W W W W W W W W W W ST W W W W W W W SS SS SS SS SS SS SS SS SS SS PARKING STRUCTURE PIAZZA WEST ELIZABETH STREET ARTERIAL 4 LANE SOUTH SHIELDS STREET ARTERIAL 4 LANE CITY PARK AVENUE LOCAL STREET WEST ELIZABETH STREET ARTERIAL 4 LANE BUILDING C FFE=~5032.00 CHURCH FFE=~5037.00 BUILDING B T T T T T T T T T T T T T X X G G G G G G G G G G G T T T T T T T T T T T T T T T T T T T T FO G FO FO FO FO FO FO FO FO FO FO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS DN FO FO FO FO FO FO FO FO FO FO FO T T G G G G G G G G G G G G G G T T T T T T ST ST ST ST ST FO FO FO FO FO FO FO FO FO G G G G G G G G G G G G G FO FO FO FO G FO FO FO FO FO FO FO FO T T T T W W W W G G G G G G G G G G T T G G G G G FO FO FO FO FO FO G G G G G G FO FO FO FO FO FO ST ST 17'-7 1 2 " 16'-6" WEST ELIZABETH STREET ARTERIAL 4 LANE ST. JOHN XXIII UNIVERSITY COMMONS ROAD 34 LIMIT OF PROPOSED OFF-SITE STRIPING TO PREVENT PROPERTY LINE OVERHANG, SUBJECT TO NEGOTIATIONS WITH AFFECTED PRIVATE PROPERTY OWNERS 32'-11 1 2 " 8'-6" 30° 18'-3" NORTH 0' 10' 20' 40' Sheet Number: Project Number: Project: Client: 1603 Oakridge Drive Fort Collins, CO 80525 p. (970) 223-7577 www.BHADesign.com Landscape Architecture Urban Design Master Planning L:\PROJECTS\SAINT JOHN XXIII\DRAWINGS\ACAD\PDP\DWG\1847 - J23 SITE PLAN.DWG Plot Date:5/1/2019 10:08 AM Plotted By: Jason Messaros Date Created:9/17/2018 Produced by: Date: Revision: 5 OF 6 Date: SITE PLAN Saint John XXIII Student Housing and Lombardy Student Housing 1220 University Ave, Fort Collins, CO 80521 BLACKBIRD INVESTMENTS LLC 130 East 3rd St. Suite 400 Des Moines, IA 50309 PROJECT DEVELOPMENT PLAN (PDP) JM 3.19.2019 1847 SCALE: 1 PROPOSED 1"=20' OFF-SITE PARKING RESTRIPE FO FO G G G G G G G G G G G G G G G G G G G FO FO FO FO FO G G FO FO FO FO FO FO FO FO FO FO SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS ADA RAMP LOADING ZONE 5' DETACHED CONCRETE WALK 6' TREE LAWN EXISTING TREE TO REMAIN AND BE PROTECTED RELOCATED BUS STOP 32' 9 PIAZZA ACCESS STEPS OFF-SITE ACCESS / CONNECTION ALIGNED WITH EXISTING WALK TO THE NORTH 27'-1 1 2 " 11'-10 1 2 " 12' 20'-8" 6' ATTACHED CONCRETE WALK 17'-2 1 2 " 6'-1 1 2 " PROPERTY LINE, TYP. PROPERTY LINE, TYP. 6' DETACHED CONCRETE WALK 20' 42'-11 2 " BIKE PARKING (28) 20' P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. 5'-31 6'-1" 2" STAIR ACCESS MONUMENT SIGN (SUBJECT TO SEPARATE SIGN PERMIT) 5' 314'-9 1 2 " SCREEN FENCE TRASH ENCLOSURE (NEWMAN CENTER AND CHURCH USE) INTERIOR TRASH ENCLOSURE (RESIDENTIAL USE) P.A. P.A. 34'-7" FLUSH CURB BIKE PARKING (14) 26'-6" 12' PIAZZA UNIVERSITY AVENUE NEWMAN CENTER FFE=~5030.50 STREET LIKE PRIVATE DRIVE 9' 17' BEGIN RAISED DRIVEWAY BEGIN RAISED DRIVEWAY TRANSFORMER PAD ADA RAMP 47'-4" FLUSH CURB BIKE PARKING (21) BIKE PARKING (14) APPROXIMATE LIMIT OF WORK, SUBJECT TO CONSTRUCTION EASEMENTS, TYP. FUTURE BUILDING ENVELOPE P.A. P.A. P.A. P.A. P.A. P.A. 21'-11 2" 46' 21'-6" 20'-8 1 2 " ART NICHE FUTURE BUILDING ENVELOPE TRASH / RECYCLING BIN MANAGEMENT ZONE CHURCH FFE=~5037.00 FIRE ACCESS ZONE ARCHITECTURAL DRAWING: TREX SECLUSIONS FENCING 6' TALL x 8' WIDE 8' O.C. 7'-7" POST PROFILE: CUT VIEW / ELEVATION VIEW 41 2" 53 4" 3 4" 3 8" 6' 2'-6" TYP. CONSULT LOCAL CONDITIONS, CODES, AND STANDARD BUILDING PRACTICES FOR POST DEPth 1' TYP 6'-15 8" 6'-21 4" NOTES: 1. INSTALLATION TO BE COMPLETED PER MANUFACTURER'S SPECIFICATION. 2. THIS DRAWING IS PROVIDED FOR PLANNING PURPOSES. REFER TO MANUFACTURER'S INSTALLATIONS FOR CONSTRUCTION DETAILS. 3. REFER TO MANUFACTURER'S WEBSITE FOR PRODUCT INFORMATION. 4. DRAWING NOT TO SCALE. CONCRETE FILL POST PROFILE: ELEVATION VIEW TOP RAIL POST CAP INTERLOCKING PICKET ALUMINUM BOTTOM RAIL FENCE BRACKET BOTTOM RAIL COVER CONCRETE FILL COLOR TBD. BROWN / GRAY NORTH 0' 10' 20' 40' MATCH LINE SEE SHEET 3 LEGEND P.A. = PLANTING AREA SCALE: 1 SCREEN 1/2"FENCE, =1'-0" TYPICAL Sheet Number: Project Number: Project: Client: 1603 Oakridge Drive Fort Collins, CO 80525 p. (970) 223-7577 www.BHADesign.com Landscape Architecture Urban Design Master Planning L:\PROJECTS\SAINT JOHN XXIII\DRAWINGS\ACAD\PDP\DWG\1847 - J23 SITE PLAN.DWG Plot Date:5/1/2019 11:43 AM Plotted By: Jason Messaros Date Created:9/17/2018 Produced by: Date: Revision: 4 OF 6 Date: SITE PLAN Saint John XXIII Catholic Church Lombardy Student Housing, PDP190001 1220 University Ave, Fort Collins, CO 80521 BLACKBIRD INVESTMENTS LLC 130 East 3rd St. Suite 400 Des Moines, IA 50309 PROJECT DEVELOPMENT PLAN (PDP) JM 5.1.2019 1847 SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W 15'-5 1 2 " 26' 26' 42'-10" 41'-1 1 2 " 5' DETACHED CONCRETE WALK 6' TREE LAWN PRIVATE COURTYARD 39'-11" 17' 26' ENCLOSED BIKE PARKING AND BIKE REPAIR STATION (252 HIGH CAPACITY) UNDER STRUCTURE BIKE PARKING (126) 14 425 CONCRETE WALK, PEDESTRIAN BOULEVARD TREE LAWN TYP. 24' PROPERTY LINE, TYP. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. P.A. EXISTING TREE TO REMAIN AND BE PROTECTED 11'-111 2" LOADING ZONE, RIDE HAILING 131'-11 1 2 " SCREEN FENCE INTERIOR TRASH /RECYCLING ROOM (RESIDENTIAL USE) BIKE PARKING (28) BIKE PARKING (7) 16' PARKING STRUCTURE BUILDING C FFE=~5032.00 BUILDING B FFE=~5033 STREET LIKE PRIVATE DRIVE UNIVERSITY AVENUE BIKE PARKING (14) MECHANICAL ROOM ACCESS TRANSFORMER PAD TRANSFORMER PAD P.A. P.A. P.A. P.A. P.A. GAS FIRE FEATURE POOL HOT TUB BBQ 75' ADA RAMP BIKE PARKING (28) BIKE PARKING (14) BIKE PARKING (14) MECHANICAL ROOM INTERIOR TRASH /RECYCLING 52'-8" ROOM (RESIDENTIAL USE) BUILDING SETBACK LINE, TYP. BIKE PARKING (7) CONCRETE DECK COURTYARD ACCESS GATE WITH KNOX BOX AND CRASH BAR EGRESS COURTYARD ACCESS GATE WITH KNOX BOX AND CRASH BAR EGRESS 521'-10 1 2 " VERTICAL CURB APPROXIMATE LIMIT OF WORK, SUBJECT TO CONSTRUCTION EASEMENTS, TYP. BBQ 14'-81 2" P.A. P.A. P.A. PERGOLA STRUCTURE, TYP. 6' METAL PICKET FENCE ON CONCRETE MOW STRIP 2' MIN . CLEAR FDC 28 R11'-6" CRITICAL ROOT ZONE EXISTING OFF SITE TRASH ENCLOSURE ENCLOSED BIKE PARKING ACCESS FDC 119'-5 1 2 " TRASH / RECYCLING BIN MANAGEMENT ZONE TRASH / RECYCLING BIN MANAGEMENT ZONE BUILDING SETBACK LINE, TYP. P.A. NORTH 0' 10' 20' 40' MATCH LINE SEE SHEET 2 LEGEND P.A. = PLANTING AREA MATCH LINE SEE SHEET 4 SITE PLAN NOTES 1. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL PLANS. AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 2. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 3. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 7. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 8. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 9. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 10. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSABLE PARKING SPACES. ACCESSABLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 11. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY A PROPERTY OWNERS’ ASSOCIATION. THE PROPERTY OWNERS’ ASSOCIATION IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. AND, IF APPLICABLE: 12. THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL LOT. 13. PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODORCONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 14. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 15. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 16. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. Sheet Number: Project Number: Project: Client: 1603 Oakridge Drive Fort Collins, CO 80525 p. (970) 223-7577 www.BHADesign.com Landscape Architecture Urban Design Master Planning L:\PROJECTS\SAINT JOHN XXIII\DRAWINGS\ACAD\PDP\DWG\1847 - J23 SITE PLAN.DWG Plot Date:5/1/2019 10:07 AM Plotted By: Jason Messaros Date Created:9/17/2018 Produced by: Date: Revision: 3 OF 6 Date: SITE PLAN Saint John XXIII Catholic Church Lombardy Student Housing, PDP190001 1220 University Ave, Fort Collins, CO 80521 BLACKBIRD INVESTMENTS LLC 130 East 3rd St. Suite 400 Des Moines, IA 50309 PROJECT DEVELOPMENT PLAN (PDP) JM 5.1.2019 1847 FFE=~5033 NEWMAN CENTER FFE=~5030.50 BUILDING A FFE=~5039 MULTI-USE STREET LIKE PRIVATE DRIVE WEST ELIZABETH STREET ARTERIAL 4 LANE SOUTH SHIELDS STREET ARTERIAL 4 LANE CITY PARK AVENUE LOCAL STREET WEST ELIZABETH STREET ARTERIAL 4 LANE CHURCH FFE=~5037.00 UNIVERSITY AVENUE C C T T T X X X T T T T T T T T T T T T T T T T T T T T T T X X X X X X X G G G G G G G G G G G G G T T T T T T T T T T T T T T T T T T T G G G G CTV CTV CTV CTV G G W G G G W W W W W W W W G G G G G G G G G G G CTV CTV CTV CTV CTV CTV SS SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W 10'-2 1 2 " 13'-10 1 2 " 15'-9 1 2 " BIKE PARKING (21) PROPERTY LINE, TYP. PROPERTY LINE, TYP. 5' DETACHED CONCRETE WALK 6' TREE LAWN EXISTING TREES TO REMAIN AND BE PROTECTED 7' ATTACHED CONCRETE WALK 7' UNIVERSITY AVENUE P.A. P.A. P.A. P.A. P.A. P.A. MONUMENT SIGN (SUBJECT TO SEPARATE SIGN PERMIT) 321'-3" SCREEN FENCE INTERIOR TRASH ENCLOSURE (RESIDENTIAL USE) P.A. BIKE PARKING (7) BIKE PARKING (7) APPROXIMATE LIMIT OF WORK, SUBJECT TO CONSTRUCTION EASEMENTS, TYP. EXISTING TREES TO REMAIN AND BE PROTECTED CONCRETE WALK 9'-9" BUILDING A FFE=~5039 P.A. P.A. 22'-71 2" 5'-8" 10' TRANSFORMER PAD MAIN ENTRY BUILDING SETBACK LINE, TYP. MATCH EXISTING BACK OF WALK BUILDING SETBACK LINE, TYP. 13'-9 1 2 " 2' MIN. CLAR FDC 15'-7" 10'-61 2" 24 26 R11' CRITICAL ROOT ZONE R12'-6" CRITICAL ROOT ZONE TRASH / RECYCLING BIN MANAGEMENT ZONE, SERVICE VEHICLE ACCESS TO DOOR. NORTH 0' 25' 50' 100' NORTH 0' 10' 20' 40' MATCH LINE SEE SHEET 3 SHEET 2 SHEET 3 SHEET 4 LEGEND P.A. = PLANTING AREA SHEET 5 Sheet Number: Project Number: Project: Client: 1603 Oakridge Drive Fort Collins, CO 80525 p. (970) 223-7577 www.BHADesign.com Landscape Architecture Urban Design Master Planning L:\PROJECTS\SAINT JOHN XXIII\DRAWINGS\ACAD\PDP\DWG\1847 - J23 SITE PLAN.DWG Plot Date:5/1/2019 10:07 AM Plotted By: Jason Messaros Date Created:9/17/2018 Produced by: Date: Revision: 2 OF 6 Date: OVERALL SITE PLAN Saint John XXIII Catholic Church Lombardy Student Housing, PDP190001 1220 University Ave, Fort Collins, CO 80521 BLACKBIRD INVESTMENTS LLC 130 East 3rd St. Suite 400 Des Moines, IA 50309 PROJECT DEVELOPMENT PLAN (PDP) JM 5.1.2019 1847 BUILDING B: (68) 0NE-BEDROOM/STUDIO UNITS (68) X .75 = 51 REQUIRED SPACES (34) TWO-BEDROOM UNITS (34) X 1 = 34 REQUIRED SPACES (31) THREE-BEDROOM UNITS (31) X 1.25 = 38.75 REQUIRED SPACES TOTAL (BUILDING B) 124 PARKING SPACES BUILDING C: (44) 0NE-BEDROOM/STUDIO UNITS (44) X .75 = 33 REQUIRED SPACES (34) TWO-BEDROOM UNITS (34) X 1 = 34 REQUIRED SPACES (26) THREE-BEDROOM UNITS (26) X 1.25 = 32.5 REQUIRED SPACES TOTAL (BUILDING C) 99.5 PARKING SPACES HOUSING: REQUIRED PARKING COUNT (PRIOR TO REDUCTIONS) = 314 SPACES REDUCTIONS BASED ON DEMAND MITIGATION STRATEGY TABLE IN LUC: · TRANSIT PASSES (10%) = 31 SPACES · CAR SHARE (5 SPACES/CARSHARE (3 SPACES)) = 12 SPACES NET · BIKE/PED. LEVEL OF SERVICE A (10%) = 31 TOTAL REDUCTION = 74 TOTAL 240 PARKING SPACES PLACE OF WORSHIP: (1 PER 4 SEATS)(750 SEATS) = 187.5 NEWMAN CENTER: (1/1000 sf.) = 9 TOTAL 197 PARKING SPACES 240 + 197 = 437 SPACES REQUIRED BY CODE PARKING PROVIDED: SURFACE PARKING: 23 STRUCTURED PARKING: 425 TOTAL (437 REQUIRED ) 448 PARKING SPACES PROVIDED BICYCLE PARKING (COVERED/FIXED) PROVIDED RESIDENTIAL: (580 BEDROOMS) 1/BEDROOM (60% / 40%) (348/232 REQUIRED) 580 TOTAL (378 COVERED / 202 FIXED) PLACES OF WORSHIP: 1/3000 sf. min. of 4 (0% / 100%) (6 REQUIRED) 6 TOTAL (0 COVERED / 6 FIXED) NEWMAN CENTER: 1/3000 sf. min. of 4 (0% / 100%) (4 REQUIRED) 4 TOTAL (0 COVERED / 4 FIXED) TOTAL (580 REQUIRED) 590 BIKE PARKING SPACES PROVIDED OWNERSHIP CERTIFICATION Director of Community Development and Neighborhood Services Community Development and Neighborhood Services Approved by the Director of Community Development and Neighborhood Services of the City of Fort Collins, Colorado this _________ day of _____________________ , 20_______. By: ______________________________________________ Date: __________________________________ THE ARCHDIOCESE OF DENVER, A COLORADO CORPORATION SOLE, AS TRUSTEE AND FOR THE BENEFIT OF ST. JOHN XXIII CATHOLIC PARISH IN FORT COLLINS Name : Title: COUNTY OF ) The foregoing instrument was acknowledged before me this _____ day of__________________, 20_____, by________________________________________________ Signature of Notary: _______________________________________________ My commission expires: ____________________________________________ address: ____________________________________________ city, state, zip: ________________________________________ STATE OF COLORADO) ) ss. Notary Seal CITY OF FORT COLLINS WATER/ WASTEWATER Contact: Shane Boyle (970) 221-6700 CITY OF FORT COLLINS STORMWATER Contact: Wes Lamarque (970) 221-6700 CITY OF FORT COLLINS LIGHT AND POWER Contact: Rob Irish (970) 224-6167 PROJECT CONTACTS UTILITY ENTITY CONTACTS POUDRE FIRE AUTHORITY Contact: Jim Lynxwiler (970) 416-2869 XCEL ENERGY - GAS & ELECTRIC Contact: Stephanie Rich (970) 225-7828 CENTURY LINK Contact: Bob Rulli (970) 490-7503 COMCAST Contact: Don Kapperman (970) 567-0245 SOURCE: GOOGLE MAPS PROPERTY OWNER THE ARCHDIOCESE OF DENVER, A COLORADO CORPORATION SOLE, AS TRUSTEE AND FOR THE BENEFIT OF ST. JOHN XXIII CATHOLIC PARISH IN FORT COLLINS 1300 South Steele Street Denver, Colorado 80210 Contact: Jarrewtt Laraway Phone: 303.715.3254 Cell: 303.880.8254 OWNER / DEVELOPER REPRESENTATIVE: BLACKBIRD INVESTMENTS, LLC 130 East 3rd St. Suite 400 Des Moines, IA 50309 Phone: 515.371.2951 LOMBARDY STUDENT HOUSING: LOMBARDY EVANGELICAL HOLDINGS 130 E 3rd St, Suite 400 Des Moines, IA. 50309 Contact: Jimmy Becker Phone: 515.371.2951 ARCHITECT (LOMBARDY STUDENT HOUSING): DAVIS PARTNERSHIP ARCHITECTS 2901 Blake Street, Suite 100 Denver, CO 80205 Phone: 303.861.8555 Fax: 303.861.3027 Contact: Scott Nevin, AIA, NCARB Principal ARCHITECT (CHURCH): INTEGRATION DESIGN GROUP, P.C. 6890 W. 52nd Ave, Suite 230 Arvada, Colorado 80002 Contact: Dale Sanders Phone: 303 227 9453 PLANNER/LANDSCAPE ARCHITECT: BHA DESIGN INC. 1603 Oakridge Drive Fort Collins, CO 80525 Contact: Jason Messaros, RLA Phone: 970.223.7577 CIVIL ENGINEER: NORTHERN ENGINEERING 201 N. Howes St, Suite 100 Fort Collins, CO 80521 Contact: Andy Reese Phone. 970.221.4158 SURVEYOR: NORTHERN ENGINEERING 201 N. Howes St, Suite 100 Fort Collins, CO 80521 Ph. 970.221.4158 Contact: Bob Tessely, PL GEOTECHNICAL ENGINEER: TERRACON 1901 Sharp Point Drive Fort Collins, CO 80525 Contact: Eric Bernhardt 970.484.0359 1. REFER TO FINAL UTILITY PLANS FOR EXACT LOCATIONS AND CONSTRUCTION INFORMATION FOR STORM DRAINAGE STRUCTURES, UTILITY MAINS AND SERVICES, PROPOSED TOPOGRAPHY, STREET IMPROVEMENTS. 2. REFER TO THE SUBDIVISION PLAT AND UTILITY PLANS FOR EXACT LOCATIONS, AREAS AND DIMENSIONS OF ALL EASEMENTS, LOTS, TRACTS, STREETS, WALKS AND OTHER SURVEY INFORMATION. 3. THE PROJECT SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FINAL AMENDMENTS TO THE PLANS MUST BE REVIEWED AND APPROVED BY THE CITY PRIOR TO THE IMPLEMENTATION OF ANY CHANGES TO THE PLANS. 4. ALL ROOFTOP AND GROUND MOUNTED MECHANICAL EQUIPMENT MUST BE SCREENED FROM VIEW FROM ADJACENT PROPERTY AND PUBLIC STREETS. IN CASES WHERE BUILDING PARAPETS DO NOT ACCOMPLISH SUFFICIENT SCREENING, THEN FREE-STANDING SCREEN WALLS MATCHING THE PREDOMINANT COLOR OF THE BUILDING SHALL BE CONSTRUCTED. OTHER MINOR EQUIPMENT SUCH AS CONDUIT, METERS AND PLUMBING VENTS SHALL BE SCREENED OR PAINTED TO MATCH SURROUNDING BUILDING SURFACES. 5. ALL CONSTRUCTION WITH THIS DEVELOPMENT PLAN MUST BE COMPLETED IN ONE PHASE UNLESS A PHASING PLAN IS SHOWN WITH THESE PLANS. 6. [IF APPLICABLE -- INCLUDE LANGUAGE FOR ANY MODIFICATIONS AND CONDITIONS APPROVED WITH PDP/ODP]. 7. [IF APPLICABLE] ALL SINGLE FAMILY DETACHED HOMES SHALL MEET OR EXCEED THE GARAGE DOOR STANDARDS AS OUTLINED IN 3.5.2(E) OF THE LAND USE 8. [IF APPLICABLE] A MINIMUM OF (NUMBER TBD) HOUSING MODELS FOR THE SINGLE FAMILY HOMES SHALL BE REQUIRED. THESE HOUSING MODELS SHALL MEET OR EXCEED THE STANDARDS AS OUTLINED IN 3.5.2(C) OF THE LAND USE 9. ALL EXTERIOR LIGHTING PROVIDED SHALL COMPLY WITH THE FOOT-CANDLE REQUIREMENTS IN SECTION 3.2.4 OF THE LAND USE CODE AND SHALL USE A CONCEALED, FULLY SHIELDED LIGHT SOURCE WITH SHARP CUT-OFF CAPABILITY SO AS TO MINIMIZE UP-LIGHT, SPILL LIGHT, GLARE AND UNNECESSARY DIFFUSION. 10. SIGNAGE AND ADDRESSING ARE NOT PERMITTED WITH THIS PLANNING DOCUMENT AND MUST BE APPROVED BY SEPARATE CITY PERMIT PRIOR TO CONSTRUCTION. SIGNS MUST COMPLY WITH CITY SIGN CODE UNLESS A SPECIFIC VARIANCE IS GRANTED BY THE CITY. 11. FIRE HYDRANTS MUST MEET OR EXCEED POUDRE FIRE AUTHORITY STANDARDS. ALL BUILDINGS MUST PROVIDE AN APPROVED FIRE EXTINGUISHING SYSTEM. 12. ALL BIKE RACKS PROVIDED MUST BE PERMANENTLY ANCHORED. 13. ALL SIDEWALKS AND RAMPS MUST CONFORM TO CITY STANDARDS. ACCESSIBLE RAMPS MUST BE PROVIDED AT ALL STREET AND DRIVE INTERSECTIONS AND AT ALL DESIGNATED ACCESSIBLE PARKING SPACES. ACCESSIBLE PARKING SPACES MUST SLOPE NO MORE THAN 1:48 IN ANY DIRECTION. ALL ACCESSIBLE ROUTES MUST SLOPE NO MORE THAN 1:20 IN DIRECTION OF TRAVEL AND WITH NO MORE THAN 1:48 CROSS SLOPE. 14. COMMON OPEN SPACE AREAS AND LANDSCAPING WITHIN RIGHT OF WAYS, STREET MEDIANS, AND TRAFFIC CIRCLES ADJACENT TO COMMON OPEN SPACE AREAS ARE REQUIRED TO BE MAINTAINED BY THE PROPERTY OWNER OF THE COMMON AREA. THE PROPERTY OWNER IS RESPONSIBLE FOR SNOW REMOVAL ON ALL ADJACENT STREET SIDEWALKS AND SIDEWALKS IN COMMON OPEN SPACE AREAS. 15. DESIGN AND INSTALLATION OF ALL PARKWAY/TREE LAWN AND MEDIAN AREAS IN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH CITY STANDARDS. UNLESS OTHERWISE AGREED TO BY THE CITY WITH THE FINAL PLANS, ALL ONGOING MAINTENANCE OF SUCH AREAS IS THE RESPONSIBILITY OF THE OWNER/DEVELOPER. 16. THE PROPERTY OWNER FOR EACH RESIDENTIAL LOT IS RESPONSIBLE FOR SNOW REMOVAL ON ALL STREET SIDEWALKS ADJACENT TO EACH RESIDENTIAL 17. PRIVATE CONDITIONS, COVENANTS, AND RESTRICTIONS (CC&R'S), OR ANY OTHER PRIVATE RESTRICTIVE COVENANT IMPOSED ON LANDOWNERS WITHIN THE DEVELOPMENT, MAY NOT BE CREATED OR ENFORCED HAVING THE EFFECT OF PROHIBITING OR LIMITING THE INSTALLATION OF XERISCAPE LANDSCAPING, SOLAR/PHOTO-VOLTAIC COLLECTORS (IF MOUNTED FLUSH UPON ANY ESTABLISHED ROOF LINE), CLOTHES LINES (IF LOCATED IN BACK YARDS), ODOR CONTROLLED COMPOST BINS, OR WHICH HAVE THE EFFECT OF REQUIRING THAT A PORTION OF ANY INDIVIDUAL LOT BE PLANTED IN TURF GRASS. 18. ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. 19. FIRE LANE MARKING: A FIRE LANE MARKING PLAN MUST BE REVIEWED AND APPROVED BY THE FIRE OFFICIAL PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. WHERE REQUIRED BY THE FIRE CODE OFFICIAL, APPROVED SIGNS OR OTHER APPROVED NOTICES THAT INCLUDE THE WORDS NO PARKING FIRE LANE SHALL BE PROVIDED FOR FIRE APPARATUS ACCESS ROADS TO IDENTIFY SUCH ROADS OR PROHIBIT THE OBSTRUCTION THEREOF. THE MEANS BY WHICH FIRE LANES ARE DESIGNATED SHALL BE MAINTAINED IN A CLEAN AND LEGIBLE CONDITION AT ALL TIMES AD BE REPLACED OR REPAIRED WHEN NECESSARY TO PROVIDE ADEQUATE VISIBILITY. 20. PREMISE IDENTIFICATION: AN ADDRESSING PLAN IS REQUIRED TO BE REVIEWED AND APPROVED BY THE CITY AND POUDRE FIRE AUTHORITY PRIOR TO THE ISSUANCE OF ANY CERTIFICATE OF OCCUPANCY. UNLESS THE PRIVATE DRIVE IS NAMED, MONUMENT SIGNAGE MAY BE REQUIRED TO ALLOW WAY-FINDING. ALL BUILDINGS SHALL HAVE ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE, VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY, AND POSTED WITH A MINIMUM OF SIX-INCH NUMERALS ON A CONTRASTING BACKGROUND. WHERE ACCESS IS BY MEANS OF A PRIVATE ROAD AND THE BUILDING CANNOT BE VIEWED FROM THE PUBLIC WAY, A MONUMENT, POLE OR OTHER SIGN OR MEANS SHALL BE USED TO IDENTIFY THE STRUCTURE. SITE PLAN NOTES: