Loading...
HomeMy WebLinkAboutSTREETS PARK - BASIC DEVELOPMENT REVIEW - BDR180010 - SUBMITTAL DOCUMENTS - ROUND 2 - ARCHITECTURAL DETAILSA B C D 3 2 1 RAISED ROOF ABOVE ROOF BELOW ROOF BELOW TYP. 1' - 6" 6' - 10 7/8" 1' - 6" PFM. LOUVER 23.05 A B C D 3 2 1 R1 R1 R1 SLOPE DOWN 1/4" / 12" SLOPE DOWN 1/4" / 12" 1' - 6" 1' - 6" 1' - 6" 5.01 5.01 SYSTEMNOTES SYSTEM NOTES--ROOFS DDDDEEEESSSSIIIIGGGGNNNNAAAATTTTIIIIOOOONNNN DDDDEEEESSSSCCCCRRRRIIIIPPPPTTTTIIIIOOOONNNN ROOF GENERAL NOTES 1. VERIFY ALL EXISTING ROOF ASSEMBLIES AND CONDITIONS AS REQUIRED 2. VERIFY & COORDINATE ALL DIMENSIONS WITH EXISTING CONDITIONS. 3. NOTIFY ARCHITECT IMMEDIATELY WITH ANY DISCREPENCIES REGARDING THE CONTRACT DOCUMENTS. R1 NEW 12" P.F. METAL STANDING SEAM OVER STRUCTURE (REF: STR'L) SHEET NUMBER SHEET NAME ISSUE DATE REVISIONS CHECKED BY JOB NUMBER DRAWN BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER THE COPYRIGHT PROTECTION ACT OF 1990. - ALL CONSTRUCTION SHALL CONFORM TO CURRENT UNIFORM BUILDING CODE AND ALL OTHER APPLICABLE CODES. - DO NOT SCALE DRAWINGS FOR DIMENSIONS. CONSTRUCTION MANAGERS, SUB- CONTRACTORS AND ALL OTHER SUPPLIERS TO THIS PROJECT, HAVE THE COMPLETE RESPONSIBILITY TO NOTIFY ENGINEERS, ARCHITECTS AND ALL OTHER DESIGN PROFESSIONALS OF ANY DIS- CREPANCIES, SYSTEMNOTES SYSTEM NOTES--RRRROOOOOOOOFFFFSSSS DDDDEEEESSSSIIIIGGGGNNNNAAAATTTTIIIIOOOONNNN DDDDEEEESSSSCCCCRRRRIIIIPPPPTTTTIIIIOOOONNNN ROOF GENERAL NOTES 1. VERIFY ALL EXISTING ROOF ASSEMBLIES AND CONDITIONS AS REQUIRED 2. VERIFY & COORDINATE ALL DIMENSIONS WITH EXISTING CONDITIONS. 3. NOTIFY ARCHITECT IMMEDIATELY WITH ANY DISCREPENCIES REGARDING THE CONTRACT DOCUMENTS. R1 NEW 12" P.F. METAL STANDING SEAM OVER STRUCTURE (REF: STR'L) SYSTEMNOTES SYSTEM NOTES--FFFFLLLLOOOOOOOORRRRSSSS DDDDEEEESSSSIIIIGGGGNNNNAAAATTTTIIIIOOOONNNN DDDDEEEESSSSCCCCRRRRIIIIPPPPTTTTIIIIOOOONNNN P1 4" REINFORCED CONCRETE SLABS, REF: STR'L 1 2 3 TRANSLUCENT POLYCARBONATE GLAZING P.F. METAL FRAME R1 R1 P1 19' - 4" 19' - 4" A B C D P.F. METAL STANDING SEAM ROOF P.F. METAL FLASHING/GUTTER & DOWNSPOUT STRUCTURAL SLAB 4" CONC. ON GRADE R1 R1 R1 P1 5.01 5.01 3 2 1 8' - 4" B. P1 R1 R1 N. D C B A M. M. M. N. N. R1 R1 R1 SHEET NUMBER SHEET NAME ISSUE DATE REVISIONS CHECKED BY JOB NUMBER DRAWN BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER THE COPYRIGHT PROTECTION ACT OF 1990. - ALL CONSTRUCTION SHALL CONFORM TO CURRENT UNIFORM BUILDING CODE AND ALL OTHER APPLICABLE CODES. SYSTEMNOTES SYSTEM NOTES--WWWWAAAALLLLLLLLSSSS DDDDEEEESSSSIIIIGGGGNNNNAAAATTTTIIIIOOOONNNN DDDDEEEESSSSCCCCRRRRIIIIPPPPTTTTIIIIOOOONNNN W1 EXISTING WALL W2 2 1/2" (25 GAUGE) MTL STUDS AT 16" O.C. W3 3 5/8" (25 GAUGE) MTL STUDS AT 16" O.C. W4 4" (25 GAUGE) C H MTL STUDS AT 16" O.C. W6 6" (25 GAUGE) MTL STUDS AT 16" O.C. C8 8" CONCRETE WALL, REF. STR'L. M4 STANDARD CONCRETE MASONRY UNIT WALL M6 COLOR/SPLIT FACE CONCRETE MASONRY UNIT WALL GENERAL WALL NOTES 1. ALL WALLS TO BE W3-A UNLESS OTHERWISE NOTED 2. PROVIDE DOUBLE 20 GA. STUDS (MIN.) AT ALL DOOR JAMBS 3. ALL DIMENSIONS ARE TO GRID LINES, FACE OF STUDS OR MASONRY WALL UNLESS OTHERWISE NOTED 4. EXTEND GYPSUM BOARD ON WALLS TO 2" ABOVE ALL ADJACENT CEILINGS AND TO UNDERSIDE OF GYPSUM CEILINGS UNLESS OTHERWISE NOTED 5. PROVIDE GYPSUM CONTROL JOINTS IN WALLS OVER 25' IN LENGTH SYSTEMNOTES SYSTEM NOTES--FLOORS DDDDEEEESSSSIIIIGGGGNNNNAAAATTTTIIIIOOOONNNN DDDDEEEESSSSCCCCRRRRIIIIPPPPTTTTIIIIOOOONNNN F2 4" REINFORCED CONCRETE SLABS, REF: STR'L F3 WOOD DECKING ON WD TRUSS JOISTS (REF: STR'L) F1 EXISTING CONCRETE FLOORS TO REMAIN P2 EXISTNG CONCRETE WALKS TO REMAIN, PATCH & REPAIR AS NEEDED P3 NEW CONCRETE WALKS P1 EXISTING ASPHALT TO REMAIN, PATCH & REPAIR AS NEEDED UTILITY / JJJJAAAANNNNIIIITTTTOOOORRRR 8' - 8" 8" 8' - 0" 8" W1 W5 W5 W1 W1 3' - 4" 1' - 4" 12' - 0" 10' - 0" 8' - 0" 10' - 0" W4 W4 10' - 8" 8' - 8" 6" 9' - 0" 6" 5' - 6" 5' - 2" EQ (TYP.) TRELLIS ABOVE WWWWOOOOMMMMEEEENNNN''''SSSS RRRREEEESSSSTTTTRRRROOOOOOOOMMMM 01 03 W1 W5 W5 W1 10' - 8" 5' - 6" 5' - 2" SYSTEMNOTES SYSTEM NOTES--ROOFS DDDDEEEESSSSIIIIGGGGNNNNAAAATTTTIIIIOOOONNNN DDDDEEEESSSSCCCCRRRRIIIIPPPPTTTTIIIIOOOONNNN ROOF GENERAL NOTES 1. VERIFY ALL EXISTING ROOF ASSEMBLIES AND CONDITIONS AS REQUIRED 2. VERIFY & COORDINATE ALL DIMENSIONS WITH EXISTING CONDITIONS. 3. NOTIFY ARCHITECT IMMEDIATELY WITH ANY DISCREPENCIES REGARDING THE CONTRACT DOCUMENTS. R1 NEW P.F. METAL STANDING SEAM OVER ____ STRUCTURE (REF: STR'L) SLOPE DOWN 1/4" / 12" R1 1' - 6" 8" 8" WALL LINE BELOW P.F.M. GUTTER & DN. SPOUT 8" 5.01 7.01 7.01 SHEET NUMBER SHEET NAME ISSUE DATE REVISIONS CHECKED BY JOB NUMBER DRAWN BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER THE COPYRIGHT PROTECTION ACT OF 1990. - ALL CONSTRUCTION SHALL CONFORM TO CURRENT UNIFORM BUILDING CODE AND ALL OTHER APPLICABLE CODES. - DO NOT SCALE DRAWINGS FOR DIMENSIONS. CONSTRUCTION MANAGERS, SUB- CONTRACTORS AND ALL OTHER SUPPLIERS TO THIS PROJECT, HAVE THE COMPLETE RESPONSIBILITY TO NOTIFY ENGINEERS, ARCHITECTS AND ALL OTHER DESIGN PROFESSIONALS OF ANY DIS- CREPANCIES, CONFLICTS, BUILDING OR OTHER CODE REQUIREMENTS AS REP- RESENTED BY THESE CONSTRUCTION DOCUMENTS. ANY PROFESSIONAL LIABILITY CLAIMS SHALL BE LIMITED TO THE EXTENT OF SAID DESIGNERS FEE, ONLY AND IS HEREBY RECOGNIZED AS SUCH BY ANY CLAIMANTS, OWNERS, LIEN HOLDERS OR OTHERS. A4.1 ROOF PLAN 02.06.18 SJS BKT Project Number FORT COLLINS PARK AND PLANNING DEVELOPMENT 215 N. MASON ST FORT COLLINS, COLORADO STREETS PARK 05.07.2018 KEY NOTES NO. DESCRIPTION 1.01 OWNER PROVIDED EQUIPMENT 2.01 EXISTING TO REMAIN 3.01 CONCRETE FOUNDATION, (REF: STRUCTRUAL) 4.01 4" BRICK VENEER WITH METAL TIES AT 16" ON CENTER HORIZ. & VERT. 5.01 PRE-FINISHED METAL FLASHING, GUTTERS & DOWNSPOUTS 5.02 CONT. P.F.M. SNOW GUARD 6.04 COUNTERTOP 7.01 SKYLIGHT / LITE TUBE 7.03 THERMAL / MOISTURE PROTECTION 9.01 FLOOR BASE 22.01 FLOOR DRAIN -( REF: PLUMBING DRWG) 22.02 MOP SINK - (REF: PLUMBING) 22.03 DRINKING FOUNTAIN (REF: PLUMBING) 23.01 ROOF PENETRATION - (REF: MECHANICAL) 23.02 RTU - (REF: MECHANICAL) 23.03 EXHAUST FAN - (REF: MECHANICAL) 26.01 LIGHTING - (REF: ELECTRICAL) NORTH A4.1 1/2" = 1'-0" 1 ROOF PLAN MMMMEEEENNNN''''SSSS RRRREEEESSSSTTTTRRRROOOOOOOOMMMM 02 1' - 4" 3' - 4" 1' - 8" 3' - 4" 3' - 0" 1' - 6" 1' - 6" 3' - 0" 2' - 6" 28' - 0" SHEET NUMBER SHEET NAME ISSUE DATE REVISIONS CHECKED BY JOB NUMBER DRAWN BY THESE PLANS ARE COPYRIGHTED AND ARE SUBJECT TO COPYRIGHT PROTECTION AS AN 'ARCHITECTURAL WORK' UNDER THE COPYRIGHT PROTECTION ACT OF 1990. - ALL CONSTRUCTION SHALL CONFORM TO CURRENT UNIFORM BUILDING CODE AND ALL OTHER APPLICABLE CODES. - DO NOT SCALE DRAWINGS FOR DIMENSIONS. CONSTRUCTION MANAGERS, SUB- CONTRACTORS AND ALL OTHER SUPPLIERS TO THIS PROJECT, HAVE THE COMPLETE RESPONSIBILITY TO NOTIFY ENGINEERS, ARCHITECTS AND ALL OTHER DESIGN PROFESSIONALS OF ANY DIS- CREPANCIES, CONFLICTS, BUILDING OR OTHER CODE REQUIREMENTS AS REP- RESENTED BY THESE CONSTRUCTION DOCUMENTS. ANY PROFESSIONAL LIABILITY CLAIMS SHALL BE LIMITED TO THE EXTENT OF SAID DESIGNERS FEE, ONLY AND IS HEREBY RECOGNIZED AS SUCH BY ANY CLAIMANTS, OWNERS, LIEN HOLDERS OR OTHERS. A2.1 FLOOR PLAN 02.13.18 SJS BKT Project Number FORT COLLINS PARK AND PLANNING DEVELOPMENT 215 N. MASON ST FORT COLLINS, COLORADO STREETS PARK KEY NOTES NO. DESCRIPTION 1.01 OWNER PROVIDED EQUIPMENT 2.01 EXISTING TO REMAIN 3.01 CONCRETE FOUNDATION, (REF: STRUCTRUAL) 4.01 4" BRICK VENEER WITH METAL TIES AT 16" ON CENTER HORIZ. & VERT. 5.01 PRE-FINISHED METAL FLASHING, GUTTERS & DOWNSPOUTS 5.02 CONT. P.F.M. SNOW GUARD 6.04 COUNTERTOP 7.01 SKYLIGHT / LITE TUBE 7.03 THERMAL / MOISTURE PROTECTION 9.01 FLOOR BASE 22.01 FLOOR DRAIN -( REF: PLUMBING DRWG) 22.02 MOP SINK - (REF: PLUMBING) 22.03 DRINKING FOUNTAIN (REF: PLUMBING) 23.01 ROOF PENETRATION - (REF: MECHANICAL) 23.02 RTU - (REF: MECHANICAL) 23.03 EXHAUST FAN - (REF: MECHANICAL) 26.01 LIGHTING - (REF: ELECTRICAL) NORTH A2.1 1/2" = 1'-0" 1 FLOOR PLAN - DO NOT SCALE DRAWINGS FOR DIMENSIONS. CONSTRUCTION MANAGERS, SUB- CONTRACTORS AND ALL OTHER SUPPLIERS TO THIS PROJECT, HAVE THE COMPLETE RESPONSIBILITY TO NOTIFY ENGINEERS, ARCHITECTS AND ALL OTHER DESIGN PROFESSIONALS OF ANY DIS- CREPANCIES, CONFLICTS, BUILDING OR OTHER CODE REQUIREMENTS AS REP- RESENTED BY THESE CONSTRUCTION DOCUMENTS. ANY PROFESSIONAL LIABILITY CLAIMS SHALL BE LIMITED TO THE EXTENT OF SAID DESIGNERS FEE, ONLY AND IS HEREBY RECOGNIZED AS SUCH BY ANY CLAIMANTS, OWNERS, LIEN HOLDERS OR OTHERS. A5.1 ELEVATIONS 02.06.18 Checker Author Project Number CITY OF FORT COLLINS PARK AND PLANNING DEVELOPMENT 215 N. MASON ST FORT COLLINS, COLORADO STREETS PARK 05.07.2018 KEY NOTES NO. DESCRIPTION 1.01 OWNER PROVIDED EQUIPMENT 2.01 EXISTING TO REMAIN 3.01 CONCRETE FOUNDATION, (REF: STRUCTRUAL) 5.01 PRE-FINISHED METAL FLASHING, GUTTERS & DOWNSPOUTS 5.02 CONT P.F.M. SNOW GUARDS 7.01 CONTINUOUS RIDGE VENT 7.02 CONTINUOUS RIDGE CAP 8.01 P.F. ALUMINUM STOREFRONT 23.01 ROOF PENETRATION - (REF: MECHANICAL) 23.02 RTU - (REF: MECHANICAL) 23.05 WALL LOUVERS - (REF: MECHANICAL) 26.01 LIGHTING - (REF: ELECTRICAL) A5.1 1/4" = 1'-0" 1 NORTH ELEVATION A5.1 1/4" = 1'-0" 2 EAST ELEVATION A5.1 1/4" = 1'-0" 3 SOUTH ELEVATION A5.1 1/4" = 1'-0" 4 WEST ELEVATION A5.1 12" = 1'-0" 5 NORTH RENDERING CONFLICTS, BUILDING OR OTHER CODE REQUIREMENTS AS REP- RESENTED BY THESE CONSTRUCTION DOCUMENTS. ANY PROFESSIONAL LIABILITY CLAIMS SHALL BE LIMITED TO THE EXTENT OF SAID DESIGNERS FEE, ONLY AND IS HEREBY RECOGNIZED AS SUCH BY ANY CLAIMANTS, OWNERS, LIEN HOLDERS OR OTHERS. A4.1 CLERESTORY & ROOF PLAN 02.06.18 Checker Author Project Number CITY OF FORT COLLINS PARK AND PLANNING DEVELOPMENT 215 N. MASON ST FORT COLLINS, COLORADO STREETS PARK 05.07.2018 KEY NOTES NO. DESCRIPTION 1.01 OWNER PROVIDED EQUIPMENT 2.01 EXISTING TO REMAIN 3.01 CONCRETE FOUNDATION, (REF: STRUCTRUAL) 5.01 PRE-FINISHED METAL FLASHING, GUTTERS & DOWNSPOUTS 5.02 CONT P.F.M. SNOW GUARDS 7.01 CONTINUOUS RIDGE VENT 7.02 CONTINUOUS RIDGE CAP 8.01 P.F. ALUMINUM STOREFRONT 23.01 ROOF PENETRATION - (REF: MECHANICAL) 23.02 RTU - (REF: MECHANICAL) 23.05 WALL LOUVERS - (REF: MECHANICAL) 26.01 LIGHTING - (REF: ELECTRICAL) NORTH A4.1 3/8" = 1'-0" 1 UPPER CLERESTORY PLAN A4.1 3/8" = 1'-0" 2 ROOF PLAN NORTH